YSI Environmental Monitoring Systems. Water Quality Training Seminar

Size: px
Start display at page:

Download "YSI Environmental Monitoring Systems. Water Quality Training Seminar"

Transcription

1 YSI Environmental Monitoring Systems Water Quality Training Seminar

2 6-Series Products 600QS 6820/ R 6820V2/6920V2 600LS 6600/6600EDS 600OMS 6600V2 600XL/600XLM

3 600 QS (Quick Sample)

4 600 QS, 600R

5 600LS

6 600XL, 600XLM, 600 OMS

7 6820V2-1, 6920V2-1

8 6820 V2-2, 6920 V2-2

9 6600V2-2

10 6600EDSV2-2

11 6600 V2-4

12 6600 V2-4 w/ PAR Photosynthetically Active Radiation (PAR)

13 Telemetry Platforms

14 Telemetry Platforms

15 Autonomous Underwater Vehicles

16 Autonomous Underwater Vehicles

17 ProPlus

18 ProODO

19 556 & 85

20 EcoSense

21 Sensor Technology

22 Sensor Technology Chlorophyll Temperature Rhodamine Conductivity Blue-Green Algae Dissolved Oxygen Chloride ph/orp Ammonia Water Depth/Level Nitrate Turbidity

23 Temperature High precision thermistor 2252 ohms at 25C (+/- 1%) Resistance changes with temperature - uses thermistor algorithm to convert to temperature Thin wall titanium sleeve Fast response Resists corrosion

24 Conductivity AC voltage applied to nickel electrodes Conductivity electrodes placed in sample to be measured Electrical current flows through the electrodes and the sample Electrical current level has direct relationship with conductivity of the solution 4 pure nickel electrodes Cell constant = 5.00 Temperature probe Fresh, brackish and sea water capability

25 Conductivity Conductivity will vary with temperature changes Specific Conductance is commonly expressed in reference to a specific temperature Specific Conductance = Conductivity corrected to 25 C.

26 Differences between ROX and Rapid Pulse Sensors ROX No electrolyte Self-cleaning sensor Not affected by H 2 S Zero-cal option Rapid Pulse Electrolyte required Not self-cleaning (EDS sonde required for membrane cleaning) Affected by H 2 S No zero-cal option

27 Dissolved Oxygen Two main types of Polarographic Oxygen Sensors Steady State Pulsed

28 Dissolved Oxygen Oxygen diffuses through Teflon membrane Oxygen reduced at gold cathode Electrons flow = electrical signal Oxygen concentration proportional to signal level e - O 2 O 2 e - Gold Cathode H 2 O e - H 2 O e - O 2 Silver Anode O 2 KCl O 2 H 2 O H2 O O 2 O 2 O 2 H 2 O H 2 O H 2 O H 2 O H 2 O H 2 O O 2 O 2 O 2 Teflon membrane H 2 O H 2 O H 2 O

29 Rapid Pulse Dissolved Oxygen On Rapid-Pulse refined the technology Pulses on / off during measurement sequence Incorporates new electrode design which utilizes a separate silver reference electrode and anode instead of combining the two. This configuration is required to polarize / de-polarize the electrode consistently for a very short period of time (40mS) Utilizes digital electronics Eliminates need for stirring 40ms Off 3960ms 4 sec

30 Rapid Pulse Dissolved Oxygen Long Term Stability Less susceptible to fouling accurate long term data Accurate results in low flow conditions no stirring device required, <2% stirring dependence Ultra low power requirements long battery life Reliable long term deployments Diagnostics Serviceable

31 Rapid Pulse Dissolved Oxygen Removed Stirring 100 Percent Saturation Rapid Pulse Response Steady State Response

32 Optical DO Step 1: The sensor emits blue light, which causes the sensing element to luminesce red light. In the presence of oxygen, the sensor measures a change in phase-shift of luminescent emissions as a function of oxygen concentration. The luminescence signal from the blue excitation is compared to that of the red excitation (next slide) and a stable DO concentration is calculated.

33 Optical DO Step 2: The sensor emits red light, which is reflected by the sensing element. The reflected red light is measured by the sensor and serves as a reference for the lifetime luminescence calculations

34 ph Glass sensing bulb is filled with solution of stable ph (ph 7) so inside of glass surface experiences constant binding of H+ ions Outside of bulb is exposed to sample where H+ varies Differential of H+ creates a potential which is read versus the stable potential of the reference electrode AgCl-coated Ag wire H + H + H + H + H + H + E membrane KCl Gel Reference Junction

35 ph Plot - Nernst Equation mv ph -200 ph slope ph /- 50mV ph slope

36 Sensor - Glass imbedded platinum ring - Solution potential read versus ph reference electrode Oxidation reduction potential (ORP) of the sample is determined by measuring the potential of a chemically-inert (platinum) electrode which is immersed in the solution The sensing electrode potential is read relative to the reference electrode of the ph probe and the value is presented in millivolts Value represents the overall oxidizing (positive values) and reducing (negative values) ability of the sample ORP

37 ISE Works exactly like ph except the sensor is a PVC membrane selective for the analyte rather than a glass bulb selective for H+ ions Sensor module contains a static concentration of the analyte which binds to the inner membrane Potential is related to the analyte concentration using the Nernst Equation

38 ISE ph Reference Electrode + - ISE Module AgCl-coated Ag wire NH 4+ solution PVC membrane with ionpore NH 4 + NH + NH NH + 4 NH 4 + NH 4 + E membrane

39 Optical Sensor Design Integrated Improved Replaceable Non-corroding Easy to wiper replace, o-ring optical wiper with titanium seals durable fiber shaft new seal switch wiper membrane for shaft controlled longer for with long-life a sensor usable parking life Hsystem 2 of S and one low year oxygen environments

40 Optical Probes Wiper Motor Wiper Sponge Wiper

41 Turbidity Techniques Nephelometric Angle of Reflection 90º ISO Recommended method

42 Turbidity Method Probe contains an LED with a wavelength of 860 NM (Emitter) Probe contains a photodiode (detector) Optical fibers connected to emitter and detector intersect probe face at opposing 45 degree angles - net angle is 90 degrees Light from emitter enters sample and scatters off the particles - light scattered at 90 degrees enter detector fiber and is measured by the photodiode Circuit board in the sonde quantifies sample signal relative to standards and generates a value in NTU Based on ISO 7027 Method

43 Turbidity Light Source (infrared) Photodetector Fiber optic cables molded at a 45 degree angle 90º Intersect

44 Chlorophyll Chlorophyll fluoresces when irradiated with light of a particular wavelength ( nm), emits light of a higher wavelength ( nm.) The ability of chlorophyll to fluoresce is the basis of commercial in-situ fluorometers. These fluorometers induce chlorophyll to fluoresce by shining a beam of light of the proper wavelength into the water and then measuring the higher wavelength light which is emitted. Measurement is made in the field without disrupting cells.

45 Chlorophyll

46 YSI 6025 Chlorophyll Probe Light Source 470 nm Photodetector Optical Filter Optical Fiber

47 YSI 6025 Chlorophyll Probe

48 Blue-Green Algae (Cyanobacteria) Theory of detection same as Chlorophyll sensors (in vivo fluorescence of pigments in living cells) Chlorophyll a not available for fluorescence detection in cyanobacteria We look for accessory pigments Phycocyanin: Freshwater Species Phycoerythrin: Saltwater Species Recommended to use chlorophyll and BGA sensors in concert If a significant BGA population is present, relying solely on the chlorophyll sensor will underestimate total algal biomass

49 Blue-Green Algae (Cyanobacteria)

50 Blue-Green Algae (Cyanobacteria) Early Warning Indicator

51 Rhodamine Probe contains an LED with a wavelength of 540 nm (Emitter) Probe contains a photodiode (detector) Optical fibers connected to emitter and detector Light from emitter enters sample and the Rhodamine WT dye in the sample fluoresces. Probe picks up the high wavelength emission, and uses filter to restrict other source of emission.

52 Rhodamine Light Source Photodetector Optical Filter Fiber optic cables

53 Depth Sensor Sensor: Stainless Steel Strain Gauge in four different sensitivities shallow vented, shallow, medium and deep. Shallow Vented 0-3m ± 0.003/3-9.1m ± 0.02m Shallow 0-9.1m ± 0.02m Medium m ± 0.12m Deep 0-200m ± 0.3m (YSI 6600 only) Voltage from Strain Gauge is proportional to hydrostatic pressure.

54 Non-Vented Depth Measurement Pressure Due to Atmosphere Pressure Due to Water Column P Total = P Water + P Atmosphere

55 Vented Depth Measurement Pressure Due to Atmosphere Pressure Due to Water Column

56 Care & Maintenance

57 Probe Installation Remove the port plug. Lightly grease the o-rings of the probe use only enough grease to make the o-ring shiny. More grease is not better it may actually hinder the seal. Align the probe in its corresponding port. Once the probe key falls into place, press the probe firmly in the bulkhead to completely seat the probe. Hold the probe with one hand to prevent twisting it while finger threading the slip nut.

58 Probe Installation If you meet resistance while threading, DO NOT continue threading. Back the slip nut out and realign the threads. Finger tighten the probe, then use the provided tool to snug the probe by turning the nut an additional ¼ turn. DO NOT over tighten. For optical probes, finger tighten, then use the provided tool to tighten the probe completely. Be sure to point the probes towards the floor while pulling from the port to minimize port contamination.

59 Temperature No maintenance required.

60 Conductivity Be sure the conductivity conduits are free from contamination/blockage. Use the small test tube brushes and a mild soap solution to periodically clean the conduits.

61 Dissolved Oxygen Membrane changes should be done as necessary (according to application) between 2-6 weeks. If the electrodes look tarnished, recondition electrode with 2400 grit sand paper (provided in 6035 kit) How do I know when it s time to recondition?

62 Dissolved Oxygen

63 Reconditioning DO Probe Remove membrane, rinse probe in clean water and dry off probe surface Use the YSI 6035 kit to service electrodes (note that the sanding disc must be struck parallel with the electrodes). Rinse probe surface area with clean water. Re-membrane probe and check DO Charge (after 5 minutes of probe burn-in). If reconditioning DO Probe does not reduce / increase charge repeat conditioning. If repeat conditioning fails, replace probe.

64 Membrane Replacement Large KCl meniscus

65 Membrane Replacement Hold the membrane with both hands and come straight down on the DO probe. Be sure not to stretch the membrane laterally, just hold it taut, and stretch it as you pull it down over the probe.

66 Be sure to adequately stretch the membrane over the probe. Membrane Replacement

67 Membrane Replacement Hold the membrane taut while placing the o-ring on to reduce bubbles and wrinkling. Be careful not to leave fingerprints on the membrane while installing the o-ring.

68 Trim the membrane about 2 to 3 mm below the o-ring. Membrane Replacement

69 The final inspection of the membrane should reveal no bubbles and no wrinkles. Membrane Replacement

70 Membranes Membranes have specific response coefficients. Membrane response coefficients are stored in the sensor and in the.glp file. Replacement membranes require new coefficients to be entered in sonde software. Membranes must remain hydrated.

71 Membrane Replacement Remove the new sensor membrane assembly from its hydrated container and dry the underside completely. Ensure both sides of the membrane cavity are dry. Topside Underside

72 Membrane Replacement 1. After installing the ROX sensor in the sonde bulkhead and replacing the membrane, connect the sonde to your computer or 650 MDS logger. 2. Locate the alphanumeric string on the sticker which contains the coded calibration information for this particular sensor membrane. 3. Access the Main Menu and select Calibrate, then Optical Dissolved Oxy. 4. Select option 3-Enter cal sheet and enter the corresponding calibration coefficients.

73 ph Clean ph Probe Dirty ph/orp Probe

74 ph Remove ph probe (if applicable) Soak in mild soap solution for 15 minutes. Rinse, then soak in tap water for 5 minutes. Soak in 1 M HCl for minutes. Rinse, then soak in tap water for 10 minutes. Soak in a 1:1 solution of bleach and water for 45 minutes. Rinse, then soak in tap water for 15 minutes.

75 Same basic care & maintenance as ph probe. ORP

76 Optical Probes Replace wiper on a regular schedule maintenance, e.g. every 30 days / before each long term deployment Wiper calibration is automatic in sondes with version 2.17 or higher. For earlier software versions, remove all power from the sonde, or if on a PC, ESC to # and type RESET <enter> Wiper calibration should be observed to confirm wiper operation Ensure wiper is not covering emitter and detector. Do not force the wiper as this will damage the motor beyond repair

77 Clean Optical Wiper

78 Dirty Optical Wiper

79 Optical Wiper

80 Depth Use the syringe provided with your maintenance kit to flush out the depth set. Do not stick anything in the holes on the depth set--you will damage the pressure transducer.

81 Calibration

82 Temperature Factory Set - No calibration required.

83 Conductivity Calibrate using SpCond (Specific Conductivity). Place into clean conductivity standard e.g.: 1000 µs/cm (most standards are labeled in µs/cm, BUT the calibration value has to be entered as a ms/cm). Allow one minute to stabilize before accepting the calibration, or if reading has not changed for 30 Sec. Check Cell Constant in Advanced Menu. Readings should be 5.0 ± 0.45 If Cell Constant is out of range clean and recalibrate. Never accept an Out of Range

84 ph In Report / Setup Parameters, enable ph mv Place into a ph 7.0 buffer and allow to stabilize for at least one minute. Record mv Offset value 0 +/- 50. Input value of ph 4.0 buffer into Sonde, then rinse. Place into a ph 4.0 buffer, the reading should be close to 4 within a few seconds. Allow to stabilize and record mv slope. Should be 180 mv different than the value recorded for ph buffer 7, +/- 50 mv. Repeat a third time using ph 10.0 buffer. mv should have a slope of -180 mv different than the value recorded for ph buffer 7, +/- 50 mv.. If mv readings/slope are out of spec, or if there is slow response, perform cleaning procedure. If the mv is out of range, or response does not improve then soak probe for hours in 2M KCl or ph 4 Buffer.

85 ORP Allow temperature to stabilize. Use temperature compensation chart that came with ORP Standard to verify value.

86 Dissolved Oxygen The following tips are how to get the most accurate results for a SAMPLING APPLICATION: Allow probe to warm-up for 4-5 minutes before accepting calibration (RS232 auto sleep disabled) Make sure probe is in a saturated environment Enter current barometer reading (mmhg) Record DO Charge for QA/QC purposes Record DO Gain for QA/QC purposes (after calibration) Confirm DO Warm-up Pattern Never accept an Out of Range

87 Dissolved Oxygen The following tips are how to get the most accurate results for an UNATTENDED APPLICATION: Probe will self calibrate after the selected warm-up time from advanced menu. (RS232 auto sleep enabled) Make sure probe is in a saturated environment Enter current barometer reading (mmhg) Record DO Charge for QA/QC purposes Record DO Gain for QA/QC purposes (after calibration) Confirm DO Warm-up Pattern Never accept an Out of Range

88 Calibration Values for Various Atmospheric Pressures & Altitudes In Hg mmhg mbars feet meters %sat

89 Checking DO Warm-up Stop Discrete and Unattended sampling. Confirm that auto-sleep RS-232 is enabled Be sure DO% is set in the report menu. Turn off Sonde for 1-2 minutes. Power up Sonde. Start discrete sampling at 4 second intervals. DO% must display a positive number and decrease with each 4 second sample, eventually stabilizing to the calibration value in approximately seconds. Disregard the first two samples they can be affected by electronics warm-up.

90 DO Warm-up Accept/Reject Criteria The DO% must start at a positive number and decrease during the warm-up. Example: 123, 117, 114, 113, 110, 107, 104, 102, 101, 100, 100 Should the display read a negative number or start at a low number and climb up to the calibration point, the probe should be rejected and must not be deployed.

91 Turbidity Choose 1 or 2-point calibration. Zero must be the first calibration point. Be sure your zero/di water is clear--no particulates. When using the cal cup, only engage one thread. If using the 6136 probe you must have a black bottom cal cup and probe guard. Never accept an Out of Range

92 Chlorophyll Do 1 point calibration to zero the probe and use for screening and/or monitoring trends Check for drift and slightly enhance accuracy using dye solution to simulate chlorophyll (2 point cal) Use extractive analysis results from field samples to post calibrate all readings Never accept an Out of Range

93 Post-calibration of In Vivo Chl Readings

94 Rhodamine Do a 2-point calibration initially. A 1 point calibration can be used to zero the probe and check for screening and/or monitoring trends Never accept an Out of Range

95 Depth Make sure flow through holes are cleaned with syringe (proved in Maintenance Kit) Leaving the Sonde in air, zero the depth sensor Using advanced menu check the Pressure Offset readings. Readings should be ± 6.0 Never accept an Out of Range

96 Tips & Tricks

97 Biofouling Prevention

98 Biofouling Prevention

99 Biofouling Prevention

100 Biofouling Prevention

101 Questions? Barrett Gaylord Northeast Representative

QUICK START GUIDE TO DRINKING WATER MONITORING

QUICK START GUIDE TO DRINKING WATER MONITORING APPENDIX F QUICK START GUIDE TO DRINKING WATER MONITORING Introduction: This Quick Start guide is designed to allow users who are already familiar with the basic use of YSI 6-series sondes for surface

More information

Optical Dissolved Oxygen Meter

Optical Dissolved Oxygen Meter Optical Dissolved Oxygen Meter HI764113 Rugged Optical Dissolved Oxygen Probe for Fresh and Saltwater Applications Digital, weighted probe No membranes No electrolytes No oxygen consumption No flow dependence

More information

Optical Dissolved Oxygen Meter

Optical Dissolved Oxygen Meter Optical Dissolved Oxygen Meter HI764113 Rugged Optical Dissolved Oxygen Probe for Fresh and Saltwater Applications Digital probe Fast and stable readings No membranes Not affected by sunlight No electrolytes

More information

Water Quality Monitoring Using a Handheld Sonde for in situ Measurements Date Prepared: 11/17/2017

Water Quality Monitoring Using a Handheld Sonde for in situ Measurements Date Prepared: 11/17/2017 PARTNERSHIP FOR THE DELAWARE ESTUARY Science Group Water Quality Monitoring Using a Handheld Sonde for in situ Measurements Date Prepared: 11/17/2017 Prepared By: Kurt Cheng Suggested Citation: Cheng,

More information

STEAM STERILIZABLE POLAROGRAPHIC OXYGEN ELECTRODE

STEAM STERILIZABLE POLAROGRAPHIC OXYGEN ELECTRODE STEAM STERILIZABLE POLAROGRAPHIC OXYGEN ELECTRODE GENERAL INFORMATION This family of dissolved oxygen electrodes is of the steam sterilizable polarographic type, designed to be interchangeable with NBS

More information

STERILIZABLE DISSOLVED OXYGEN SENSORS

STERILIZABLE DISSOLVED OXYGEN SENSORS STERILIZABLE DISSOLVED OXYGEN SENSORS USER MANUAL Table of Contents 1. Introduction 2. Operation 3. Calibration 4. Electrode Verification 5. Mounting 6. Maintenance 7. Storage 8. Instructions for Exchange

More information

PRODUCT SHEET. Order probe only as RXPROBE02

PRODUCT SHEET. Order probe only as RXPROBE02 SS69L DISSOLVED OXYGEN PROBE TRANSDUCER Order probe only as RXPROBE02 Order interface only as BSL-TCI16 SS69L Components The SS69L transducer measures dissolved oxygen. The SS69L includes a dissolved oxygen

More information

Bante810 Benchtop Dissolved Oxygen Meter Instruction Manual

Bante810 Benchtop Dissolved Oxygen Meter Instruction Manual Bante810 Benchtop Dissolved Oxygen Meter Instruction Manual BANTE INSTRUMENTS CO., LTD Bante810 Benchtop Dissolved Oxygen Meter 1 Introduction Thank you for selecting the Bante810 benchtop dissolved oxygen

More information

DOscan10 Pocket Dissolved Oxygen Tester Instruction Manual

DOscan10 Pocket Dissolved Oxygen Tester Instruction Manual DOscan10 Pocket Dissolved Oxygen Tester Instruction Manual BANTE INSTRUMENTS CO., LTD DOscan10 Pocket Dissolved Oxygen Tester 1 Thank you for selecting the DOscan10 pocket dissolved oxygen tester. This

More information

6-SERIES ENVIRONMENTAL MONITORING SYSTEMS. Service Manual

6-SERIES ENVIRONMENTAL MONITORING SYSTEMS. Service Manual 6-SERIES ENVIRONMENTAL MONITORING SYSTEMS Service Manual CONTENTS SECTION 1 INTRODUCTION... 1 1.1 HOW TO USE THIS MANUAL... 1 1.2 QUALIFICATIONS... 1 1.3 SERVICE PHILOSOPHY... 1 1.4 PC BOARD HANDLING...

More information

Heavy Duty Dissolved Oxygen Meter

Heavy Duty Dissolved Oxygen Meter User's Manual Heavy Duty Dissolved Oxygen Meter Model 407510 Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 FAX 781.665.0780 - TestEquipmentDepot.com Introduction Congratulations

More information

User's Manual. Heavy Duty Dissolved Oxygen Meter. Model

User's Manual. Heavy Duty Dissolved Oxygen Meter. Model User's Manual Heavy Duty Dissolved Oxygen Meter Model 407510 Introduction Congratulations on your purchase of Extech's Heavy Duty Dissolved Oxygen / Temperature Meter which simultaneously displays Dissolved

More information

D-OptoLogger Dissolved Oxygen Logger Operation Manual

D-OptoLogger Dissolved Oxygen Logger Operation Manual D-OptoLogger Dissolved Oxygen Logger Operation Manual Software version 3.4 Contents 1. Introduction..... 1 Optical Sensor Technology.....1 Features...... 1 2. D-OptoLogger Specifications.2 Specifications...

More information

Instruction Sheet. Important Note: Information that requires special emphasis. Note: Information that supplements points in the main text.

Instruction Sheet. Important Note: Information that requires special emphasis. Note: Information that supplements points in the main text. Hach LDO Sensor Instruction Sheet 00745589 Safety Precautions Please read this entire instruction sheet before operating this sensor. Pay particular attention to all danger and caution statements. Failure

More information

Dissolved Oxygen Guide

Dissolved Oxygen Guide Educat i onser i es Di ssol vedoxygengui de Dissolved Oxygen Guide Introduction Dissolved oxygen probes provide a convenient approach to essentially direct measurement of molecular oxygen. The membrane

More information

LogIT Dissolved Oxygen Probe

LogIT Dissolved Oxygen Probe LogIT Dissolved Oxygen Probe INTRODUCTION The LogIT Dissolved Oxygen Probe (DO2) has been designed especially for LogIT and is easy to set up and use. It features simple single control calibration and

More information

Bante820 Portable Dissolved Oxygen Meter Instruction Manual

Bante820 Portable Dissolved Oxygen Meter Instruction Manual Bante820 Portable Dissolved Oxygen Meter Instruction Manual BANTE INSTRUMENTS CO., LTD Bante820 Portable Dissolved Oxygen Meter 1 Introduction Thank you for selecting the Bante820 portable dissolved oxygen

More information

6-Series Multiparameter Water Quality Sondes. User Manual. 6-Series: 6600 V2 6600EDS V V V2 600 OMS V2 600XL 600XLM 600LS 600R 600QS

6-Series Multiparameter Water Quality Sondes. User Manual. 6-Series: 6600 V2 6600EDS V V V2 600 OMS V2 600XL 600XLM 600LS 600R 600QS 6-Series Multiparameter Water Quality Sondes User Manual 6-Series: 6600 V2 6600EDS V2 6920 V2 6820 V2 600 OMS V2 600XL 600XLM 600LS 600R 600QS SAFETY NOTES TECHNICAL SUPPORT AND WARRANTY INFORMATION Contact

More information

Best Practice for Calibrating LTH Conductivity Instruments

Best Practice for Calibrating LTH Conductivity Instruments Application Note Best Practice for Calibrating LTH Conductivity Instruments As accurate process measurement becomes an everyday requirement it is vital to be able to calibrate conductivity instruments

More information

Columbus Instruments

Columbus Instruments 0215-003M Portable O 2 /CO 2 /CH 4 Meter User s Manual Columbus Instruments 950 NORTH HAGUE AVENUE TEL:(614) 276-0861 COLUMBUS, OHIO 43204, USA FAX:(614) 276-0529 1 www.colinst.com TOLL FREE 1-800-669-5011

More information

Dissolved Oxygen and measurement possibilities. Berno Lüpkes, 15 th March 2017

Dissolved Oxygen and measurement possibilities. Berno Lüpkes, 15 th March 2017 Dissolved Oxygen and measurement possibilities Berno Lüpkes, 15 th March 2017 Content 1. Introduction to Dissolved Oxygen 2. Amperometric measurement principle 3. Optical measurement principle 4. Optical

More information

6-SERIES 6600 Sonde 6600 EDS Sonde 6920 Sonde 6820 Sonde 600XLM Sonde 600 OMS Sonde 600XL Sonde 600QS Sonde 600R Sonde 650 MDS Display/Logger

6-SERIES 6600 Sonde 6600 EDS Sonde 6920 Sonde 6820 Sonde 600XLM Sonde 600 OMS Sonde 600XL Sonde 600QS Sonde 600R Sonde 650 MDS Display/Logger 6-SERIES 6600 Sonde 6600 EDS Sonde 6920 Sonde 6820 Sonde 600XLM Sonde 600 OMS Sonde 600XL Sonde 600QS Sonde 600R Sonde 650 MDS Display/Logger Environmental Monitoring Systems SAFETY NOTES TECHNICAL SUPPORT

More information

OxyScan Graphic. Operating Instructions. UMS Micro-oxygen sensor 501. Microprocessor instrument

OxyScan Graphic. Operating Instructions. UMS Micro-oxygen sensor 501. Microprocessor instrument OxyScan Graphic Operating Instructions UMS Micro-oxygen sensor 501 Microprocessor instrument Introduction Thank you for choosing the UMS Micro Oxygen Sensor 501 - a highly advanced product! Please read

More information

Gas Pressure Probe. Information Sheet. Total Dissolved Gas

Gas Pressure Probe. Information Sheet. Total Dissolved Gas Total Dissolved Gas Information Sheet T900 Total Dissolved Gas Pressure Probe Description The In-Situ Inc. T900 probe is a specially adapted submersible pressure transducer designed to monitor Total Dissolved

More information

BI-680 Online Dissolved Oxygen Controller Instruction Manual

BI-680 Online Dissolved Oxygen Controller Instruction Manual BI-680 Online Dissolved Oxygen Controller Instruction Manual BANTE INSTRUMENTS CO., LTD BI-680 Online Dissolved Oxygen Controller 1 Introduction Thank you for selecting the BI-680 online dissolved oxygen

More information

User Manual DOCUMENT # Pro20 Pro20i USER MANUAL. English

User Manual DOCUMENT # Pro20 Pro20i USER MANUAL. English User Manual DOCUMENT #605597 Pro20 Pro20i USER MANUAL English Item #605597 Rev C, September 2016 For the latest version of this manual, visit ysi.com 2016 YSI Incorporated. The YSI logo is a registered

More information

Environmental Monitoring Systems 6-SERIES

Environmental Monitoring Systems 6-SERIES 6-SERIES 6600 Sonde 6920 Sonde 6820 Sonde 600XLM Sonde 600XL Sonde 600R Sonde 610D Display/Logger 610DM Display/Logger Environmental Monitoring Systems SAFETY NOTES TECHNICAL SUPPORT AND WARRANTY INFORMATION

More information

D-Opto Dissolved Oxygen Sensor Operation Manual for the D-Opto 4-20mA

D-Opto Dissolved Oxygen Sensor Operation Manual for the D-Opto 4-20mA D-Opto Dissolved Oxygen Sensor Operation Manual for the D-Opto 4-20mA Software version 2.6 Table of contents 1 Introduction...3 1.1 Optical Sensor Technology...3 1.2 Installation...4 1.3 Operation...5

More information

Instruction Manual HI Portable Waterproof Dissolved Oxygen Meter.

Instruction Manual HI Portable Waterproof Dissolved Oxygen Meter. Instruction Manual HI 9142 Portable Waterproof Dissolved Oxygen Meter www.hannainst.com 1 Dear Customer, Thank you for choosing a Hanna Instruments Product. Please read this instruction manual carefully

More information

PRO20 USER MANUAL. English. Français. Español. Deutsch

PRO20 USER MANUAL. English. Français. Español. Deutsch PRO20 USER MANUAL English Français Español Deutsch Item # 605597 Rev A Drawing # A605597 May 2008 2008 YSI Incorporated. The YSI logo is a registered trademark of YSI Incorporated. Teflon is a registered

More information

Bante821 Portable Dissolved Oxygen Meter Instruction Manual

Bante821 Portable Dissolved Oxygen Meter Instruction Manual Bante821 Portable Dissolved Oxygen Meter Instruction Manual BANTE INSTRUMENTS CO., LTD Bante821 Portable Dissolved Oxygen Meter 1 Introduction Thank you for selecting the Bante821 portable dissolved oxygen

More information

The Oxygen Sensor can be connected to all types of einstein Tablets, einstein LabMate, and einstein LabMate +.

The Oxygen Sensor can be connected to all types of einstein Tablets, einstein LabMate, and einstein LabMate +. The Oxygen sensor is a maintenance- free galvanic oxygen electrode capable of measuring Oxygen in solutions. With built-in temperature compensation, this sensor provides an easy way for students to receive

More information

Radnoti Liver Perfusion System

Radnoti Liver Perfusion System Radnoti Liver Perfusion System 130003 Offset Offset Gain Gain Radnoti 2006 Description Qty Part # A Base only, for 4-bar stand 1 159950-B4 B Stabilizer Bar only, for 4-Bar stand 2 159950-C4 C Rod 24 Long

More information

Unisense In Situ UniAmp Connector System

Unisense In Situ UniAmp Connector System Unisense In Situ UniAmp Connector System Overview The Unisense In Situ UniAmp Connector system is designed for easy replacement of sensors. Unisense In Situ UniAmp Connector system is a dedicated system

More information

Mini-Pro CO2 Sensor User s Manual - ANALOG MODEL -

Mini-Pro CO2 Sensor User s Manual - ANALOG MODEL - Mini-Pro CO2 Sensor User s Manual - ANALOG MODEL - Table of Contents 1. Introduction 3 2. Instrument Setup 4 2.1 Instrument Checklist 4 2.2 Optional Accessories 4 2.3 Gas Concentration Ranges Available

More information

Yeo-Kal Electronics Pty Ltd 18/26 Wattle Road, Brookvale NSW Australia Telephone Fax USER MANUAL

Yeo-Kal Electronics Pty Ltd 18/26 Wattle Road, Brookvale NSW Australia Telephone Fax USER MANUAL Yeo-Kal Electronics Pty Ltd 18/26 Wattle Road, Brookvale NSW Australia Telephone +61 2 9939 2616 Fax +61 2 9905 1100 USER MANUAL Model 621 Real time Water Quality Data Probe Version 1.0 Date 27/7/2017

More information

Measuring the Conductivity of Pure Water Using USP<645>

Measuring the Conductivity of Pure Water Using USP<645> Measuring the Conductivity of Pure Water Using USP Water Analysis Instruments, Thermo Fisher Scientific Application Notes 002 Key Words Water conductivity, ultrapure water (UPW), USP, water quality,

More information

ISE-730 Oxygen Electrode and DO2-100 Currentto-Voltage

ISE-730 Oxygen Electrode and DO2-100 Currentto-Voltage Technical Note ISE-730 and DO2-100 Overview In 1954, Dr. Leland Clark invented the first membrane-covered electrode designed to measure the concentration of oxygen in blood, or solution. This electrode

More information

FLUORESCENCE DETERMINATION OF OXYGEN

FLUORESCENCE DETERMINATION OF OXYGEN FLUORESCENCE DETERMINATION OF OXYGEN Objectives This experiment will familiarize the students with the principles of fluorescence quenching as well as the Ocean Optics FOXY Fiber Optic Sensor System. Spectra

More information

CCS240 and CCS241. Technical Information. Sensors for chlorine dioxide Amperometric, membrane-covered sensors for installation in the CCA250 assembly

CCS240 and CCS241. Technical Information. Sensors for chlorine dioxide Amperometric, membrane-covered sensors for installation in the CCA250 assembly Technical Information CCS240 and CCS241 Sensors for chlorine dioxide Amperometric, membrane-covered sensors for installation in the CCA250 assembly Application Chlorine dioxide is used for disinfection

More information

INSTRUCTION MANUAL. 840 Transmitter. Loop Powered Dissolved Oxygen Transmitter

INSTRUCTION MANUAL. 840 Transmitter. Loop Powered Dissolved Oxygen Transmitter INSTRUCTION MANUAL Loop Powered Dissolved Oxygen Transmitter Contents Contents...2 Introduction...3 Range and Display Settings...4 Installation...5 Electrical Installation...6 Calibration...7 EasyCal...8

More information

Oxymax H COS21. Technical Information. Sensor with long-term stability for frequent sterilization and autoclaving

Oxymax H COS21. Technical Information. Sensor with long-term stability for frequent sterilization and autoclaving Technical Information Oxymax H COS21 Sensor with long-term stability for frequent sterilization and autoclaving Application Process control in enzyme production Control of culture growth Biotechnological

More information

Pool and Spa. Water Testing

Pool and Spa. Water Testing Pool and Spa Water Testing Pocket Digital Testers for Pools HI-701 Checker: Free Chlorine Hand-held Colorimeter The HI-701 is a simple, accurate and cost effective way to measure free chlorine. Free Chlorine:

More information

Oxygen Measurement Systems High Reliability and Wide Application Coverage

Oxygen Measurement Systems High Reliability and Wide Application Coverage Introduction High Process Efficiency Under Any Condition Oxygen Measurement Systems High Reliability and Wide Application Coverage METTLER TOLEDO provides sensors to measure dissolved oxygen (DO) in demanding

More information

Improve Process Reliability

Improve Process Reliability Convenient Conductivity Calibration to Meet Pharmacopeia Regulations Pharmacopeias require that conductivity measurement systems be periodically calibrated to ensure their precision. The range of accessories

More information

SS32L Dissolved O 2 Probe

SS32L Dissolved O 2 Probe BIOPAC WWW.biopac.com Systems, Inc. Application Note PH-185 SS32L Dissolved O 2 Probe SS32L Dissolved O 2 Probe BIOPAC Software SS32L Specifications BSL PRO v. 3.6.6 BIOPAC Hardware SS32L Dissolved O 2

More information

Oxygen Sensor with Electrode

Oxygen Sensor with Electrode imagine explore learn Oxygen Sensor with Electrode Product Number: ENOXY-A222 Overview The Oxygen sensor is a maintenance-free galvanic oxygen electrode, capable of measuring Oxygen both in the air and

More information

Introduction The Smart Q Oxygen Adaptor enables an Oxygen electrode to be connected to an EasySense unit.

Introduction The Smart Q Oxygen Adaptor enables an Oxygen electrode to be connected to an EasySense unit. The Oxygen Adaptor & Electrode Arbor Scientific Oxygen Adapter (Product No PC-3130) Comes with Oxygen Electrode (PC-3131) 3 membrane modules 50 ml electrolyte Polishing paper for cathode Oxygen Electrode

More information

D-Opto Dissolved Oxygen Sensor Operation Manual

D-Opto Dissolved Oxygen Sensor Operation Manual D-Opto Dissolved Oxygen Sensor Operation Manual Software version 2.6 Contents 1. Introduction..... 1 Optical Sensor Technology.... 1 Features...... 1 2. D-Opto Specifications. 2 Specifications... 2 3.

More information

Dissolved Oxygen/Temp Waterproof Tester

Dissolved Oxygen/Temp Waterproof Tester User's Guide AM-DO-01 Battery Compartment Cap Main Display Dissolved Oxygen/Temp Waterproof Tester Lanyard Connection old/max/min Button Function Mode Button Power / Calibration Button Probe Coller Probe

More information

Oxygen Measurement in Natural Gas

Oxygen Measurement in Natural Gas Oxygen Measurement in Natural Gas Application Background Natural Gas Fuel is primarily methane. If it were pure methane, it would be very simple to transport and use. But it comes out of the well as a

More information

MODEL GT820 OXYGEN SENSOR

MODEL GT820 OXYGEN SENSOR INSTRUCTION MANUAL MODEL GT820 OXYGEN SENSOR 70046 The information and technical data disclosed by this document may be used and disseminated only for the purposes and to the extent specifically authorized

More information

FTS SUBMERSIBLE PRESSURE TRANSMITTER USER S MANUAL

FTS SUBMERSIBLE PRESSURE TRANSMITTER USER S MANUAL FTS SUBMERSIBLE PRESSURE TRANSMITTER USER S MANUAL TABLE OF CONTENTS PRODUCT OVERVIEW 2 I - USE AND CARE: 3 II - INSTALLATION: 5 III - GENERAL MAINTENANCE TIPS: 5 IV - APPENDIX: A-1 2-WIRE CURRENT LOOP

More information

D-Opto. Dissolved Oxygen Sensor. Operation Manual (Software Version 1.0)

D-Opto. Dissolved Oxygen Sensor. Operation Manual (Software Version 1.0) D-Opto Dissolved Oxygen Sensor Operation Manual (Software Version 1.0) Table of contents 1 Introduction...3 1.1 Optical Sensor Technology...3 2 Software...4 2.1 Installation...4 2.2 Operation...4 3 Operation...9

More information

A180 DO/BOD/OUR/SOUR Meter Instruction Manual

A180 DO/BOD/OUR/SOUR Meter Instruction Manual A180 DO/BOD/OUR/SOUR Meter Instruction Manual BANTE INSTRUMENTS CO., LTD A180 DO/BOD/OUR/SOUR Meter 1 Introduction Thank you for selecting the A180 multiparameter dissolved oxygen meter. This manual provides

More information

CB-150 Data Buoy Quick Start Guide

CB-150 Data Buoy Quick Start Guide CB-150 Data Buoy Quick Start Guide The NexSens CB-150 Data Buoy is designed for deployment in lakes, rivers, coastal waters, harbors, estuaries and other freshwater or marine environments. The floating

More information

Aerobic Respiration. Evaluation copy

Aerobic Respiration. Evaluation copy Aerobic Respiration Computer 17 Aerobic cellular respiration is the process of converting the chemical energy of organic molecules into a form immediately usable by organisms. Glucose may be oxidized completely

More information

Refillable ORP/Redox Probe: Model MTC30101 or MTC30103

Refillable ORP/Redox Probe: Model MTC30101 or MTC30103 User Manual Refillable ORP/Redox Probe: Model MTC30101 or MTC30103 DOC022.53.80026 Safety information Precautionary labels Read all labels and tags attached to the instrument. Personal injury or damage

More information

Best Practice Guide, Servomex 2700

Best Practice Guide, Servomex 2700 For full installations details refer to the. Best Practice Guide, Servomex 2700 Mounting: General Guidelines: Servomex 2700 Control Units and air supplies (utilities units) should, ideally, be mounted

More information

HOBO U20 Water Level Logger (U x and U x-Ti) Manual

HOBO U20 Water Level Logger (U x and U x-Ti) Manual HOBO U20 Water Level Logger (U20-001-0x and U20-001-0x-Ti) Manual The HOBO U20 Water Level Logger is used for monitoring changing water levels in a wide range of applications including streams, lakes,

More information

HI 2314 HI 2315 HI 23151

HI 2314 HI 2315 HI 23151 Instruction Manual HI 2314 HI 2315 HI 23151 Multi-Range Conductivity Meters for Laboratories www.hannainst.com Dear Customer, Thank you for choosing a Hanna Instruments product. Please read this instruction

More information

DISSOLVED OXYGEN SENSOR BT34i

DISSOLVED OXYGEN SENSOR BT34i DISSOLVED OXYGEN SENSOR BT34i USER S GUIDE CENTRE FOR MICROCOMPUTER APPLICATIONS http://www.cma-science.nl Short description The CMA Dissolved Oxygen (DO) sensor BT34i measures the concentration of dissolved

More information

New Generation System M, leading the World in the Non-Invasive Measurement of Critical Real-Time Parameters.

New Generation System M, leading the World in the Non-Invasive Measurement of Critical Real-Time Parameters. New Generation System M, leading the World in the Non-Invasive Measurement of Critical Real-Time Parameters. System M Spectrum Medicals total commitment to continuous product improvement is demonstrated

More information

Pneumatic high-pressure controller Model CPC7000

Pneumatic high-pressure controller Model CPC7000 Calibration technology Pneumatic high-pressure controller Model CPC7000 WIKA data sheet CT 27.63 Applications Healthcare and avionics industry Industry (laboratory, workshop and production) Transmitter

More information

Onset Computer Corporation Inside this package: HOBO U20 Water Level Logger Calibration Certificate

Onset Computer Corporation Inside this package: HOBO U20 Water Level Logger Calibration Certificate Onset Computer Corporation Inside this package: HOBO U20 Water Level Logger Calibration Certificate Models The Water Level logger is available in the following models: U20-001-01 (30 foot depth) and U20-001-01-Ti

More information

EC214 EC215 - EC215R Bench Conductivity Meters

EC214 EC215 - EC215R Bench Conductivity Meters Instruction Manual EC214 EC215 - EC215R Bench Conductivity Meters http://www.hannainst.com These Instruments are in Compliance with the CE Directives Dear Customer, Thank you for choosing a Hanna Instruments

More information

Calcimeter Instruction Manual

Calcimeter Instruction Manual Hohner (UK - Canada - Texas) Calcimeter Instruction Manual The Hohner Calcimeter is based on industry standard versions, and is used to measure the calcium carbonate and magnesium carbonate in samples.

More information

Dissolved Oxygen Meter. ino2. Instruction Manual. Serial No..

Dissolved Oxygen Meter. ino2. Instruction Manual. Serial No.. Innovative Instruments, Inc. http://www.2in.com Dissolved Oxygen Meter ino2 Instruction Manual Serial No.. Innovative Instruments, Inc. 8533 Queen Brooks Ct. Tampa, FL 33637. USA Phone: 813-727-0676. Fax:

More information

Oxymax W COS51D. Technical Information. Digital sensor for measuring dissolved oxygen Membrane-covered amperometric sensor

Oxymax W COS51D. Technical Information. Digital sensor for measuring dissolved oxygen Membrane-covered amperometric sensor Technical Information Oxymax W COS51D Digital sensor for measuring dissolved oxygen Membrane-covered amperometric sensor Application The continuous measurement of the concentration of dissolved oxygen

More information

Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter

Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter Overview C % ppm 4~20mA Analog Output ppb Power Supply 100~240 VAC mg/l Dimensions 96 x 96 x 132mm RS-485 Digital Output (for DC-5310-RS only)

More information

NEULOG OXYGEN LOGGER SENSOR GUIDE

NEULOG OXYGEN LOGGER SENSOR GUIDE NeuLog oxygen logger sensor NUL-205 The oxygen sensor can be used for any science experiment or activity where oxygen levels, dissolved or gaseous, are required. Some fields of study include Chemistry,

More information

Instructions for Assembly, Installation, and Operation of the Gas Addition Kit Accessory with the CEM Discover Systems

Instructions for Assembly, Installation, and Operation of the Gas Addition Kit Accessory with the CEM Discover Systems Corporation Issued: 5/09 P/N: 600104 Rev. 2 Instructions for Assembly, Installation, and Operation of the Gas Addition Kit Accessory with the CEM Discover Systems The Gas Addition Accessory permits the

More information

Oxymax W COS41. Technical Information. Potentiostatic amperometric two-electrode sensor Long-term stable sensor for water and wastewater applications

Oxymax W COS41. Technical Information. Potentiostatic amperometric two-electrode sensor Long-term stable sensor for water and wastewater applications Technical Information Oxymax W COS41 Potentiostatic amperometric two-electrode sensor Long-term stable sensor for water and wastewater applications Application The continuous measurement of the dissolved

More information

Oxygen Dipping Probe PSt3 / PSt6 / PSt9

Oxygen Dipping Probe PSt3 / PSt6 / PSt9 Oxygen Dipping Probe PSt3 / PSt6 / PSt9 SENSOR PROBES Instruction Manual Oxygen Dipping Probe PSt3 / PSt6 / PSt9 Specification: Oxygen dipping probe with high grade stainless steel fitting for normal

More information

STANDARD OPERATING PROCEDURES. Andersen Instruments Federal Reference Method (FRM) Ambient Particulate (PM 10 /PM 2.

STANDARD OPERATING PROCEDURES. Andersen Instruments Federal Reference Method (FRM) Ambient Particulate (PM 10 /PM 2. STANDARD OPERATING PROCEDURES Andersen Instruments Federal Reference Method (FRM) Ambient Particulate (PM 10 /PM 2.5 ) Sampler (RAAS) AMBIENT AIR MONITORING PROGRAM for the 130 LIBERTY STREET DECONSTRUCTION

More information

OxyProbe II Instruction Manual

OxyProbe II Instruction Manual OxyProbe II Instruction Manual D500 T82 Pg13.5 threaded nut O-Ring Sensor Shaft D600 ESSENTIAL INSTRUCTIONS: READ THIS PAGE BEFORE PROCEEDING! This product has been designed, manufactured, and tested to

More information

Instruction Manual HI Portable Dissolved Oxygen Meter. DO meter HI 8043 STB C OFF O 2 ZERO SLOPE C. ins rum n s

Instruction Manual HI Portable Dissolved Oxygen Meter. DO meter HI 8043 STB C OFF O 2 ZERO SLOPE C. ins rum n s Instruction Manual HI 8043 Portable Dissolved Oxygen Meter DO meter HI 8043 ZERO SLOPE C ins rum n s This Instrument is in Compliance with the CE Directives Dear Customer, Thank you for choosing a Hanna

More information

Dissolved Oxygen Sensor

Dissolved Oxygen Sensor Instruction Manual 499ADO and 499ADO-VP LIQ_MAN_ABR_499ADO May 2014 Dissolved Oxygen Sensor CAUTION For additional information, please visit our website at www.rosemountanalytical.com SENSOR/PROCESS APPLICATION

More information

_ pressure transducers. User Manual

_ pressure transducers. User Manual _ pressure transducers User Manual summary introduction DescriPTION preliminary checks Installation taking measurements data management Troubleshooting maintenance Appendix 1 Page 4 Page 5 Page 6 Page

More information

HOBO U20L Water Level Logger (U20L-0x) Manual

HOBO U20L Water Level Logger (U20L-0x) Manual Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 - TestEquipmentDepot.com HOBO U20L Water Level Logger (U20L-0x) Manual The HOBO U20L Water Level Logger is used for monitoring

More information

Water Samplers, Water Sampling with Internal Recording, Cabling, and Deployment

Water Samplers, Water Sampling with Internal Recording, Cabling, and Deployment Water Samplers, Water Sampling with Internal Recording, Cabling, and Deployment Water Samplers Care and feeding SeatermAF User interface for internally recording instruments firing water samplers with

More information

Salinity and Dissolved Oxygen (D.O.) Lecture 2

Salinity and Dissolved Oxygen (D.O.) Lecture 2 Salinity and Dissolved Oxygen (D.O.) Lecture 2 Salinity defn Salinity is the saltiness or dissolved salt content of a body of water. fresh water (or sweet water) is less than 0.05%. brackish water is 0.03

More information

How to specify a product. Process Sensors and Mechanical Instruments

How to specify a product. Process Sensors and Mechanical Instruments How to specify a product Process Sensors and Mechanical Instruments Keep the overview. Here is some guideline information on how to specify our products. Intended as supplementary help to specification

More information

Blood Parameter Monitoring System 550

Blood Parameter Monitoring System 550 Technical Compendium CDI Blood Parameter Monitoring System 550 An overview of the CDI System 550 and its industry leading technology. CDI System 550 Measures or Calculates 12 Critical Blood Parameters

More information

Evaluation copy. Interdependence of Plants and Animals. computer OBJECTIVES MATERIALS

Evaluation copy. Interdependence of Plants and Animals. computer OBJECTIVES MATERIALS Interdependence of Plants and Animals Computer 14 Plants and animals share many of the same chemicals throughout their lives. In most ecosystems, O 2, CO 2, water, food and nutrients are exchanged between

More information

Overview. Front Panel: Keypad and Display

Overview. Front Panel: Keypad and Display Overview The GA-200B is an analyzer that integrates a gas sampling system with sensors to measure and display the concentrations of oxygen and carbon dioxide in a sample as the percentage of a gas in the

More information

OUS31. Technical Information

OUS31. Technical Information Technical Information OUS Turbidity sensor Installation and immersion sensor for drinking water and industrial water according to the 90 scattered light method Application All phases of drinking water

More information

Calibration and Maintenance Procedures: YSI ProDSS rev 8/31/15

Calibration and Maintenance Procedures: YSI ProDSS rev 8/31/15 Calibration and Maintenance Procedures: YSI ProDSS rev 8/31/15 These procedures are to be performed by program staff or people who have been trained by staff. Calibration frequency will depend upon the

More information

Test Plans & Test Results

Test Plans & Test Results P09051 Oxygen Gas Sensor Test Plans & Test Results By: Samuel H Shin (EE), Jeremy Goodman (ue) Table of contents 1. TITLE: OXYGEN MEASUREMENT TEST VIA FABRICATED OXYGEN GAS SENSOR SYSTEM... 2 1.1. Introduction...

More information

Three Lakes Association Hydrolab for Dummies. Table of Contents:

Three Lakes Association Hydrolab for Dummies. Table of Contents: Three Lakes Association Hydrolab for Dummies 1 Table of Contents: 1. Know before you start:...2 a-introduction b-unpacking c-general use d-be careful 2. Calibration:...3 a-step by step guide 3. Using the

More information

Application Note AN-107

Application Note AN-107 SPEC Sensor TM Characterization & Calibration Considerations Scope This document is provided to describe the considerations needed to characterize, calibrate, verify and validate the measurement performance

More information

PRESSURE SENSOR - ABSOLUTE (0 TO 700 kpa)

PRESSURE SENSOR - ABSOLUTE (0 TO 700 kpa) Instruction Sheet for the PASCO Model CI-6532A PRESSURE SENSOR - ABSOLUTE (0 TO 700 kpa) 012-06859B 10/98 $1.00 polyurethane tubing syringe cable with DIN s to computer interface quick release s (4) pressure

More information

T02.0.3X.6C-06 Page 1 of 6. Operating Manual for Dissolved Oxygen-Measuring transducer OXY 3610 MP

T02.0.3X.6C-06 Page 1 of 6. Operating Manual for Dissolved Oxygen-Measuring transducer OXY 3610 MP T02.0.3X.6C-06 Page 1 of 6 Specification: Measuring range: Operating Manual for Dissolved Oxygen-Measuring transducer OXY 3610 MP 0.00.. 25.00 mg/l dissolved oxygen Output signal: refer to type plate Accuracy:

More information

High-performance submersible pressure transmitter For level measurement Model LH-10

High-performance submersible pressure transmitter For level measurement Model LH-10 Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-10 WIKA data sheet PE 81.09 Applications Level measurement in rivers and lakes Deep well

More information

Instruction Manual DO 6. Economy Hand-held Dissolved Oxygen Meter. 68X Rev 2 Apr 08. Technology Made Easy... Part of Thermo Fisher Scientific

Instruction Manual DO 6. Economy Hand-held Dissolved Oxygen Meter. 68X Rev 2 Apr 08. Technology Made Easy... Part of Thermo Fisher Scientific Instruction Manual DO 6 Economy Hand-held Dissolved Oxygen Meter Technology Made Easy... 68X243622 Rev 2 Apr 08 Part of Thermo Fisher Scientific Preface This manual serves to explain the use of the DO

More information

DEVICES FOR FIELD DETERMINATION OF WATER VAPOR IN NATURAL GAS Betsy Murphy MNM Enterprises 801 N. Riverside Drive Fort Worth, Texas 76111

DEVICES FOR FIELD DETERMINATION OF WATER VAPOR IN NATURAL GAS Betsy Murphy MNM Enterprises 801 N. Riverside Drive Fort Worth, Texas 76111 INTRODUCTION Water vapor in natural gas has more than a substantial effect on the quality of the gas stream. Without quality measurement of water vapor the gas is basically not saleable. Contracts are

More information

MMS Mercury Monitoring System for Natural Gas

MMS Mercury Monitoring System for Natural Gas MMS Mercury Monitoring System for Natural Gas Natural gas often contains mercury at concentrations that vary from below 1 to above 10000 µg/m 3. Mercury is both toxic and potentially damaging: it can corrode

More information

STARLOG. Capacitive Water Depth Probe

STARLOG. Capacitive Water Depth Probe STARLOG Capacitive Water Depth Probe Model 6521 User Manual Supplement 6219 Revision D July 10. 1998 Copyright Notice Copyright Unidata Australia 1998. All rights reserved. No part of this publication

More information

RDO Optical Dissolved Oxygen Sensor

RDO Optical Dissolved Oxygen Sensor Manual 51A-RDO Sensor April 2010 Model RDO Sensor RDO Optical Dissolved Oxygen Sensor RDO is a registered trademark of In-Situ Inc. All rights reserved. RDO PROBE SPECIFICATIONS Wetted Materials: Delrin

More information

Triton DO8 Dissolved Oxygen Sensors ELECTRO-CHEMICAL DEVICES

Triton DO8 Dissolved Oxygen Sensors ELECTRO-CHEMICAL DEVICES Triton DO8 Dissolved Oxygen Sensors ELECTRO-CHEMICAL DEVICES What is the Triton DO8? The Triton DO8 is an Optical Dissolved Oxygen Analyzer DO8 Sensor & DO8 Instrument Measures the Partial Pressure of

More information