with remote seals for gauge / absolute pressure and level Spans:6 kpa MPa ( psi) 6 kpa abs... 3 MPa abs. (0.9...

Size: px
Start display at page:

Download "with remote seals for gauge / absolute pressure and level Spans:6 kpa MPa ( psi) 6 kpa abs... 3 MPa abs. (0.9..."

Transcription

1 Multi Vision 2020TG/TA Digital transitters with reote seals for gauge / absolute pressure and level Spans:6 kpa MPa ( psi) 6 kpa abs MPa abs. ( psia) 10/ EN M01515x1.tif Isolation between process and transitter for edia with high teperatures and viscosities corrosive ingredients, a tendency to polyerization Prevention of deposits in the process connection flanges by extended reote seals Mounting to various DIN or ANSI flanges High overload capability Span and zero externally adjustable Transfer response configurable: linear freely prograable In conjunction with the LCD indicator, the transitter can be configured with the external keys Counication protocol: PROFIBUS PA FOUNDATION Fieldbus HART A Surge voltage resistant acc. to IEC Interchangeable electronics with self reconfiguration Application The Multi Vision - series is a coplete series of differential pressure, gauge pressure and absolute pressure transitters with an analogue or digital output signal for the process industry. The transitter 2020TG with reote seal easures gauge pressure or level, the transitter 2020TA absolute pressure of aggressive / non-aggressive edia. It is based on a highly-stable sensor, on which a reote seal in flange design is fitted (directly or with capillary tube). The internal sensing diaphrag is slightly deflected corresponding to the pressure present at the reote seal and converted into an electrical signal by the electronics. The process-wetted parts of the reote seal can be selected fro different aterials such as stainless steel, Hastelloy C or tantalu and others, depending on the required resistance to corrosion. Various filling liquids, for exaple for the food and beverages industry, coplete the spectru of applications.

2 Description Principle of operation and construction The transitter has a odular design and consists of the gauge pressure/absolute pressure sensor odule on which a reote seal in flange design is fitted (directly or with capillary tube) with an integrated electronic atching unit and an aplifier with control unit. The applied process pressure (p e / p abs. ) is transferred via the reote seal diaphrag and the fill fluid to the easuring diaphrag of the pressure sensor. A inial deflection of the easuring diaphrag changes the output voltage of the pick-up syste. This output voltage, proportional to the pressure, is converted by the atching unit and the aplifier into an electrical signal. Exaple: Transitter 2020TG with directly connected flush diaphrag reote seal Lower range value Span Write protect Output Power supply Matching TEST INSTRUMENT Microprocessor-based electronics # Measuring echanis Process connection M01514x1_en.eps Technical data Input Measured value 2020TG: Gauge pressure 2020TA: Absolute pressure Measuring range (upper and lower range values) Lower range value (continuously adjustable) 2020TG: -100 % ( 100 kpa) up to +100 % of the URL 2020TA: 0 % up to +100 % of the URL Application liits dependent of the filling liquid: see Table 2 Upper range value (continuously adjustable) Up to 100 % of the URL Spans (dependent of reote seal type!) The adjusted span ust not be lower than the iniu range. Sallest span see table 1 Type of construction, spans... Measuring ranges Code in. ax. B 6 kpa / 60 / 25 in. H 2 O C 40 kpa / 400 / 160 in. H 2 O D 250 kpa / 2.5 / 1000 in. H 2 O F 3 MPa / 30 / 450 psi G see Table 1 10 MPa / 100 / 1500 psi H 60 MPa / 600 / 9000 psi K 6 kpa / 60 abs. / 25 in. H 2 O L 40 kpa / 400 abs. / 160 in. H 2 O M 250 kpa / 2.5 abs. / 1000 in. H 2 O O 3 MPa / 30 abs. / 450 psia Output Output signal Transitters with A Analogue signal A Output signal liits: I in 3.5 A, I ax 22.5 A (conf.) Standard setting: I in 3.8 A, I ax 20.5 A Alar current Min. alar current: configurable fro 3.5 A to 4 A, standard setting: 3.6 A Max. alar current: conf. fro 20 A to 22.5 A, standard setting: 21 A Standard setting: ax. alar current Load of transitters with A Us 10 5V R , in koh I ax I ax A (configurable) Us supply voltage in. power supply: 10.5 VDC, 14 V DC with backlit LCD-indic. in. load for digital counications > 250 Oh Fieldbus units (counication code: P / F) Digital signal Transission technique:acc. to IEC Power supply: 10.2 V DC V DC Base current: 14 A Transission rate: kbd/s PROFIBUS-PA: Version 3.0, Profile B for pressure transitters; Ident No.: 04C2 HEX FOUNDATION Fieldbus:FF-890 / 891 ans FF-902 / 903 Characteristic Linear, freely prograable with 20 reference points Page 2 of

3 Technical data Accuracy Reference conditions to DIN IEC Teperature: 20 (68 F) Relative huidity: 65 % Atospheric conditions:1013 (1013 hpa / 14.7 psia) Additional conditions: Linear output and transitters with easuring ranges > 250 kpa...60 MPa (1000 in. H 2 O psi): Separating diaphrag aterial Hastelloy C, fill fluid silicone oil All specifications are liits and relate to the output range or calibrated range. The influences arked relate to the easuring range (URL) and are to be ultiplied by the turn down factor (ratio range (URL)/calibrated span). The turn down factor should be kept to a iniu. The accuracy and response ties are dependent upon the reote seal and the easuring point. Data for the instruent cobination are only possible after knowledge of all the data subitted in the questionnaire 80/ EN (see pages 15 and 16). Data for transitter (without effect fro the reote seal): Confority % 1), terinal based, including hysteresis and the dead band Reproducibility 0.01 % Hysteresis 0.05 % War-up tie < 15 s 1) additionally with turn-down factor > 10:1 ± ( easuring range )% adjusted span Rise tie The tie behaviour of this transitter is coposed of the rise tie of the sensor and an adjustable integration tie constant of the A/D converter. A high tie constant results into a high resolution, e.g. required for a high span ratio, and at the sae tie into a higher rise tie for the output signal. A low tie constant eans a lower resolution, but a shorter rise tie and thus a faster reaction tie of the transitter. In case of the standard integration tie constant the values shown in the table below apply. 1 : 10 linear turn down factor > 1 : 10 up to 1 : 20 > 1 : 20 up to 1 : 40 additional adjustable tie constant > 1: s freely prograable function ~ 0.3 s ~ 0.5 s ~ 0.9 s ~ 1.4 s ~ 0.5 s The effect appearing at the output for non-linear output depends on the function and is to be calculated accordingly. Long-ter drift 0.05 % per 12 onths Abient teperature effect Theral change ( ) 2) /(-40 F F) 2) on zero 0.1 % on span 0.1 % Teperature coefficient ( ) 2) /(-40 F F) 2) on zero 0.04 % per 10K (50 F) on span 0.04 % per 10K (50 F) Effect of electro-agnetic interference 0.05 % 2) with carbon fluoride filling liquid: (-4 F F) * please refer to Accuracy / Reference conditions Page 3 of 21

4 Technical data Installation conditions Reote Seal with Capillary Tube: The axiun difference in height between the reote seal and the transitter when ounting the reote seal below the transitter is: with silicone oil (IB) 5.0 with carbon fluoride (L) 2.5 with high teperature oil (IH) 5.0 with white oil (WB) 2.5 with vacuuproof design (IC) 0.0 Caution: With an operating pressure < 1000 abs, the transitter ust be ounted at the sae height or below the reote seal. The iniu bending radius of the capillary tube is 75 ; do not kink! Mounting Flange Reote Seal with Flush / Extended diaphrag: The reote seal is ounted at the DIN / ANSI connection flange with a gasket (soft packing) and fixing screws on site. (Gasket and fixing screws not supplied) Only gaskets of soft aterials to be used with reote seals having diaphrags and sealing surfaces ade of tantalu. In-line Reote Seal: The reote seal is ounted direct in the process piping between two flanges. Reote Seal with Fast Coupling: The reote seal is ounted directly onto the process via either a Running union or a clap connection. Miniature Reote Seal: The threaded reote seal is screwed with the available threaded process connector. Transitter: The transitter is wall or pipe ounted, when the transitter is connected to the reote seal with a flexible capillary tube. When the transitter is directly connected to the reote seal, then no suppleentary ountings or supports are necessary. The electronic housing can be rotated through 360 and can be fixed in any position. A stop prevents the housing beeing turned too far. Installation position: The transitter can be directly ounted in any position. Preferably in a vertical position. Deviations fro this can cause a shift in the zero, which can be corrected. Abient conditions Abient teperature, transitter: T in : dependent of the filling liquid, T ax : +85 / (185 F), Observe approvals for explosion-protected transitters! Storage teperature / transport teperature , with LCD-indicator (-58 F F), with LCD-indicator ( -40 F F) Huidity Relative huidity: 95 % annual average Condensation, icing: adissible Protection class IP 67 acc. to EN ( NEMA Standard Type 6); with easuring ranges 30 (range-code: B, C, D or F) and with Han 8U plug: IP 65 ( NEMA Standard Type 4x) Protective varnish epoxy resin, greywhite, RAL 9002 Electroagnetic copatibility (EMC) to EN Definition: Class 3 Radio suppression (EN ): Liit class B Fulfills NAMUR recoendation. Process conditions Teperature liits at the reote seal: Mediu teperature (ax. abient teperature in brackets) for direct ounting: ax ( + 40 ) (Code-No. 699) ax F ( +104 F) ax ( + 60 ) ax F ( +140 F) inial ediu teperature dependent on the filling liqiuid (see Table 2) Reote seal with Running Union and Buna O-ring: axial +120 / (248 F) with Capillary tube: dependent on the filling liquid (see Table 2) with the following restrictions: Flush diaphrag DN 25 / DN 1 : axial +250 (482 F) Flush diaphrag, aterial tantalu: ax (428 F) In-line reote seal DN 25 / DN 1 : axial +250 (482 F) Pressure liits Fro vacuu (with corresponding instruent version, s. Table 2,) up to axiu span Over-ranging liit Measuring ranges 400 : 10 ( 160 in. H 2 O) (150 psi) Measuring ranges : 2 ties upper range value (1000 in. H 2 O psi) Measuring range 600 : 900 (9000 psi) (13000 psi) Weight Transitter: approx.1.2 kg Capillary tube: approx kg/ Flange Reote Seals with Flush diaphrag /Extended diaphrag DN50 / 2, DN 80 / 3 : - DN 50, PN16/40 with Flush diaphrag: approx. 3.3 kg - DN 2, Class 300 with Flush diaphrag: approx. 3.7 kg - DN 50, PN 16/40 w. Extended diaphr.100 : approx. 4.0 kg - DN 2, Class 300 w. Extended diaphr.100 : approx. 5.4 kg - DN 80, PN16/40 with Flush diaphrag: approx. 5.8 kg - DN 3, Class 150 with Flush diaphrag: approx. 5.3 kg - DN 80, PN 16/40 w. Extended diaphr.100 : approx. 7.5 kg - DN 3, Class 150 w. Extended diaphr.100 : approx. 7.0 kg Flush Diaphrag Reote Seals DN 25 / 1, Miniature Reote Seals, In-line Reote Seals and Fast Coupled Reote Seals: See diensional drawings Page 4 of

5 Technical data Electrical specifications Electrical connections Two feale threads 1/2-14 NPT or M 20 x 1.5 or one plug Han 8 U (with Profibus PA: plug connector M 12 [without feale ating plug]). Screw terinals for wire cross-sections up to Cable connection copartent /electrical connection Cable entry (e.g. via M 20 x 1.5) Test sockets for 4 20 A (not in function with fieldbus transitters) Screw terinals for 2 0,5...2,5 -wires Electrical connection with plug ~2.01(51) ~3.5(89) Barrel-type Locking screw for EEx d Contact insert (view onto sockets) Earthing / potential equalizing terinal Output signal / power supply Earthing / potential equalizing terinal M01434x1_en.eps 1.02 (26) DIN-type M01449x1_en.eps Auxiliary energy Transitters with A (counication code: H) Power supply: V DC ( V DC with backlit indicator), inverse polarity protection. Explosion-protected transitters, observe the approvals! Har. distortion: Maxial perissible voltage ripple of the power supply during counication: 7 V pp at 50 Hz f 100 Hz 1 V pp at 100 Hz < f 200 Hz 0.2 V pp at 200 Hz < f 300 Hz Field Bus units (counication code: P/F) Power supply V DC, inverse polarity protection. Explosion-protected transitters, observe the approvals! Pollution degree 2 according to ANSI / ISA Overvoltage category II according to ANSI / ISA Display and operating interface Operation with keys Retrofit / optional key unit for external adjustent of zero and span and a write protect switch. There are no physical connections through the housing for the keys. In conjunction with an LCD indicator, the transitter can be configured with the keys as follows: Zero and span with or without applied pressure, oblique sensor, daping, output current during faults, displayed value, pressure unit, characteristic curve adjustent: linear or freely prograed, teperature unit, as well as address with fieldbus devices. Operation via reote counications Counication protocol PROFIBUS-PA or FOUNDATION Fieldbus or HART Hardware for HART : FSK ode for PC / notebook Handheld Terinal STT 04 or HHT 275 or 691 HT Manageent-Software SMART VISION : fro version DTM (Device Type Manager) 2000T LCD indicator 2-line, 6-character 19-segent alphanueric display with additional chart display, optionally with back illuination. User-specific displays: Pressure value as a physical unit or percentage of the output current or output current in A or instruent teperature in freely selectable units or free process variable address (only with Fieldbus-Transitters) Diagnostic essages, alars, easuring range infringeents and changes in the configuration are also displayed Page 5 of 21

6 Technical data Hazardous atospheres Transitters of protection type Intrinsically safe EEx ia" according to Directive 94 / 9 / EC (ATEX) Transitters with A output signal and HART counication Marking: II 1/2 GD T 50 EEx ia IIC T6 II 1/2 GD T 95 EEx ia IIC T4 EC type exaination certificate nuber: ZELM 01 ATEX 0064 and 1 st. / 2 nd. Suppleent Supply and signal circuit with type of protection Intrinsic Safety EEx ib IIB/IIC or EEx ia IIB/IIC for connection to supply units with the following axiu values: II 1/2 GD T 50 EEx ia or ib IIC T6 II 1/2 GD T 95 EEx ia or ib IIC T4 for Teperature Class T4: 30 V U i I i 200 A P i 0.8 W for T4 with Ta / ( F) P i 1.0 W for T4 with Ta / ( F) for Teperature ClassT6: P i 0.7 W for T6 with Ta ( F) Effective internal capacitance C i 10 nf Effective internal inductance L i 0 Do not install 2020TG/TA transitters with easuring ranges < 400 and which are supplied through an intrinsically safe current circuit in the partition between category 1G and 2G. Fieldbus transitters (PROFIBUS PA / FOUNDATION Fieldbus) Marking : II 1/2 GD T 50 EEx ia IIC T6 II 1/2 GD T 95 EEx ia IIC T4 EC type exaination certificate nuber: ZELM 01 ATEX 0063 and 1 st. Suppleent Supply and signal circuit with type of protection Intrinsic Safety EEx ia IIB/IIC or EEx ib IIB/IIC for connection to FISCO supply units with rectangluar or trapezoidal characteristics with the following axiu values: II 1/2 GD T 50 EEx ia or ib IIC T6 U i 17.5 V II 1/2 GD T 95 EEx ia or ib IIC T4 l i 360 A P i 2.52 W II 1/2 GD T 50 EEx ia or ib IIB T6 U i 17.5 V II 1/2 GD T 95 EEx ia or ib IIB T4 l i 380 A P i 5.32 W or for connecion to supply unit / rier with linear characteristic. Maxiu values: II 1/2 GD T 50 EEx ia or ib IIC T6 U i 24 V II 1/2 GD T 95 EEx ia or ib IIC T4 l i 250 A P i 1.2 W Effective internal inductance L i 10 µh, Effective internal capacitance C i 0 Maxiu perissible abient teperatures depending on the teperature class: Teperature class Transitters of Category 3 for use in Zone 2 according to Directive 94 / 9 / EC (ATEX) Transitters with A output signal and HART counication Marking: II 3 GD T 50 EEx nl IIC T6 II 3 GD T 95 EEx nl IIC T4 EC type exaination certificate nuber: ZELM 01 ATEX 3059 and 1 st. Suppleent Operating conditions: Supply and signal circuit (terinals signal + / -): Min. perissible abient teperature U 45 V I 22.5 A Max. perissible abient teperature T4-40 (-40 F) +85 (+185 F) T5, T6-40 (-40 F) +40 (+104 F) Max. perissible abient teperatures depending on the teperature class: T4 Ta / ( F) T5, T6 Ta / ( F) Transitters of protection type Flaeproof enclosure EEx d according to Directive 94 / 9 / EC (ATEX) Transitters with A output signal and HART counication and fieldbus transitters (PROFIBUS PA / FOUNDATION Fieldbus) Marking: II 1/2 G EEx d IIC T6 EC type exaination certificate nuber: PTB 00 ATEX 1018 Operating conditions: Abient teperature range: / ( F) Factory Mutual (FM) Transitters with A output signal and HART counication Intrinsically Safe Class I; Division 1; Groups A, B, C, D; Class I; Zone 0; Group IIC; AEx ia IIC Degree of protection: NEMA Type 4X (indoor or outdoor) Maxiu perissible abient teperatures depending on the teperature class U ax 30 V, C i 10.5 nf, L i 10 µh Abient teperature ( F) ( F) ( F) Teperature I ax P i class T4 200 A 0.80 W 1.00 W T5 25 A 0.75 W T W Page 6 of

7 Technical data Hazardous atospheres (continued) Fieldbus transitters (PROFIBUS PA / FOUNDATION Fieldbus) Intrinsically Safe Class I, II, and III Division 1 Groups A, B, C, D, E, F, G; Class I, Zone 0, AEx ia Group IIC T6; T4 Non-incendive Class I, II, and III, Div. 2, Groups A, B, C, D, F, G Canadian Standard (CSA) Transitters with A output signal and HART counication and fieldbus transitters (PROFIBUS PA / FOUNDATION Fieldbus) Explosion-Proof: Class I, Division 1, Groups B, C, D Class II/III, Division 1, Groups E, F, G Degr. of protection: NEMA Type 4X (indoor or outdoor) Transitters with A output signal and HART counication and fieldbus transitters (PROFIBUS PA / FOUNDATION Fieldbus) Explosion-Proof: Class I, Division 1, Groups A, B, C, D Class II / III, Division 1, Groups E, F, G Degr. of protection: NEMA Type 4X (indoor or outdoor) Tables Table 1: Type of construction, spans and length of capillary tube Reote seal type Noinal diaeter Min. / ax. span Max. length of capillary tube Flush diaphrag DN 25 / DN / DN 50 / DN / DN 80 / DN ) / Extended diaphrag DN 50 / DN / DN 80 / DN ) / In-line reote seal DN 25 / DN 1 4 / DN 40 / DN 1 1/2 2.5 / DN 50 / DN / DN 80 / DN / with fast coupling Running union acc. to DIN DN / Clap connection DN 2 6 / Miniature reote seal G 1 A 6 / G 1 1/2 A 1.2 / ) With 2020TA use 400 abs. range. When selecting the transitter range, consider the noinal pressure (PN) of the reote seal! Table 2: Application liits: perissible teperature / iniu operating pressure Note: The pressure ust be linearly interpolated between the stated teperatures. Flush diaphrag reote seals with tantalu diaphrags (code No. P02, P05, P08, P11, P14, P17, P20, P23) should not be used at operating teperatures of ore than 220 (428 F). Filling liquid Identification Density at 20 (68 F) in kg/ 3 Silicone oil IC 1055 Carbon fluoride L 1880 High-teperature oil IH 1070 White oil WB 849 Vacuu-proof design IC-V 1055 Operating teperature in (in F) ( ) ( ) ( ) ( ) ( ) Pressure rating in abs. at 20 ( 68 F) 100 (212 F) 150 (302 F) 200 (392 F) 250 (482 F) 400 (752 F) > 500 > 500 > 500 > 750 > > 1000 > 1000 > > 500 > 500 > 500 > 750 > 1000 > 1000 > 500 > 1000 > 1000 > > 5 > 25 > 38 > Page 7 of 21

8 Ordering inforation Catalog No. Code EUR Delivery Transitter 2020TG for Pressure / Level Measureent V ,- 4 wks Transitter 2020TA for Absolute Pressure Measureent V ,- 4 wks Counication HART, A H - - Foundation Fieldbus F +161,- - PROFIBUS-PA P +161,- - Measuring Ranges 60 (6kPa / 25 inch H2O) adj. to 1), 2) B (40kPa / 160 inch H2O) adj. to 1), 2) C (250kPa / 1000 inch H2O) adj. to 1), 2) D (3MPa / 450 psi) adj. to 1), 2) F (10MPa / 1500 psi) adj. to 1), 2) G (60MPa / 9000 psi) adj. to 1), 2) H abs. (40kPa / 160 inch H2O) adj. to 1), 2) L + 107, abs. (250kPa / 1000 inch H2O) adj. to 1), 2) M abs. (3MPa / 450 psi) adj. to 1), 2) O - - Measuring sensor (ranges 60 and 400 ) Diaphrag O-ring Ceraics Perbunan Ceraics for Vacuuproof design (Code No. 739) H - - Measuring sensor (ranges 2.5 up to 600 (range-code: D,F,G,H,M,O,)) Diaphrag Fill fluid Hastelloy C Silicone oil Carbon fluoride ,- - White oil (Tep. Liits: ) ,- + 2 wks (+14 F +248 F) Material process connection Stainless steel A - - Process connection for reote seal G - - 1) Possible units:,, at, Pa, kpa, MPa, H 2 O, in H 2 O, fth 2 O, Hg, in Hg, g/c², kg/c², psi, torr 2) Copleted questionnaire 80/ (page 15/16) necessary, w hen connection via capillary tube takes place and reote seal and transitter are not at the sae height. Page 8 of

9 Ordering inforation Catalog No. Code EUR Delivery Aplifier Housing Type Material Electrical connection Barrel - Type, Aluiniu 1/2 NPT A 1) + 15,- +2 wk s ID Plate, Stainless Steel Barrel - Type, Aluiniu 1/2 NPT D - - ID Plate Plastic One M20 x 1.5 cable gland E - - Plug Han 8U, F + 53,- - (with Profibus PA: plug M12 2) ) Barrel - Type, Stainless Steel 1/2 NPT J + 349,- - ID Plate Plastic One M20 x 1.5 cable gland K + 349,- - DIN - Type, Aluiniu 1/2 NPT L - - ID Plate Plastic One M20 x 1.5 cable gland M - - Plug Han 8U, N + 53,- - (with Profibus PA: plug M12 2) ) Aplifier housing accessories Local keys (not with aplifier housing Code J, K) 5C2 + 13,- - LCD indicator 5C ,- - LCD indicator, back lit (only with counication HART, 4 20 A) 5C ,- - Transient Suppression (not with Ex-Protection "Intrinsically Safe") 5C ,- - Explosion Protection (acc. to ATEX) II 1/2 G EEx d IIC T6 (not with housing Code F or N; without cable gland) ( not with range B, C, L) 5A1 + 33,- - FM Explosion Proof (only with aplifier housing code A and not with range B, C, L) 5A2 + 33,- +2 wks II 1/2 GD EEx ia IIC T6 5A3 + 16,- - FM Intrinsically Safe 5A4 + 16,- - II 3 GD EEx nl IIC T6 (supply without cable gland) 5AC + 16,- - Mounting Bracket Wall and pipe ounting, carbon steel ,- - Wall and pipe ounting, stainless steel ,- - Tag-No. on Type plate (ax. 30 characters) Stainless Steel Tag Plate (ax. 30 characters) 5C8 + 14,- - Operating anual (1 pcs. free of charge) Geran each Z2D + 11,- - English each Z2E + 11,- - Certificates Factory Certificate EN of the instruent design ,- - Acceptance Test Certificate B EN of the confority, hysteresis ,- - Acceptance Test Certificate B EN of the pressure testing ,- - Factory Certificate EN of process wetted parts ,- - Acceptance Test Certificate B EN of the Cleanliness Stage acc. to DIN ,- - Accept. Test Certificate B EN Heliu leakage test of the sensor odule (only with Code 150) ,- - Acceptance Test Certificate B EN of the pressure-bearing and process wetted parts with ,- +2 wks analysis certificates as aterial verification (inor parts with Factory Certificate acc. to EN ) Factory Certificate EN of the pressure-bearing and process wetted parts ,- - 1) for Explosion Proof acc. to FM 2) without ating plug (feale), see Data Sheet 10/ Scope of Delivery Supplied against special order: 1 Instructions Power supply e.g. TZN 128 (Data Sheet EN) 1 Instruent socket with plug connector Spare Parts Transitter 2020TG / 2020TA (only with plug-connection Han 8U) Manageent Software SMART VISION (Data Sheet 10/ ) Page 9 of 21

10 Flush diaphrag reote seal DN 25/ DN 1 (with internal diaphrag) Options Code-No. EUR Delivery Reote seal ounting 1) Directly ounted (without capillary tube) Connection to sensor with capillary tube Materials Diaphrag and sealing surface ade of stainless steel 316 Ti (1.4571) Sealing ring (only with noinal pressure up to PN 63 or 600 psi) PTFE Flange acc. to DIN 2501, ade of stainless steel 316 Ti (1.4571) Noinal diaeter Pressure rating Sealing surface DN 25 PN 10 / 40 For D (DIN 2526) P ,- + 2 wk s DN 25 PN 10 / 40 For N (DIN 2512) P ,- + 2 wk s DN 25 PN 63 / 100 For D (DIN 2526) ,- + 3 wk s DN 25 PN 160 For D (DIN 2526) ,- + 3 wks DN 25 PN 250 For D (DIN 2526) ,- + 3 wks acc. to ANSI B 16.5, ade of stainless steel 316 Ti (1.4571) Noinal diaeter Pressure rating Sealing surface DN 1" Class 150 psi For RF P ,- + 2 wks DN 1" Class 300 psi For RF P ,- + 2 wks DN 1" Class 600 psi For RF ,- + 3 wks DN 1" Class 1500 psi For RF ,- + 3 wks Filling Liquid Silicone oil Vacuuproof design (is always necessary with 2020TA) ,- + 4 wks Lengths of capillary tube , , , ,- - Special length between 1 and 6 Basic price of the next longer standard length plus an extra fee ,- - Special features Capillary tube with PVC protective cover 775 8,- / - Other variations regarding pressure rating, aterial, sealing surface, filling liquid on request The three-digit code nubers are added to the order nuber, separated by diagonal strokes. 1) When ounted on an absolute or gauge pressure transitter for easureent < 500 (abs,), the vacuuproof design ust be ordered (Code.No. 739). Page 10 of

11 Flush diaphrag seal / Extended diaphrag seal DN 50 / DN 2 (coplete with flange) Options Code-No. EUR Delivery Reote seal ounting Directly ounted (without capillary tube) Connection to sensor with capillary tube Noinal diaeter Sealing surface Diaphrag / sealing DN 50 For E (DIN 2526) 316 L st.st. (1.4404) P ,- + 1 wk Hastelloy C P ,- + 2 wk s Tantalu P ,- + 2 wk s For V 13 (DIN 2513) 316 L st.st. (1.4404) P ,- + 1 wk Hastelloy C P ,- + 2 wk s Tantalu P ,- + 3 wks For N (DIN 2512) 316 L st.st. (1.4404) P ,- + 1 wk Hastelloy C P ,- + 3 wk s Tantalu P ,- + 3 wks DN 2" For RF (ANSI B 16.5) 316 L st.st. (1.4404) P ,- + 1 wk Hastelloy C P ,- + 2 wk s Tantalu P ,- + 3 wks Flange / Pressure rating DN 50 PN 16 / 40 P PN 64 diaph. Tantalu on request P ,- - PN 100 diaph. Tantalu on request P ,- - ANSI 2" Class 150 psi only sealing RF P Class 300 psi only sealing RF P ,- - Class 600 psi only sealing RF, diaph. Tantalu on request P ,- - Flush diaphrag / extended diaphrag Reote seal with flush diaphrag (without extension) P Reote seal with extension (not cobineable with diaphrag aterial "Tantalu") DN 50 / 2" Extension ade of 316 L st.st. Extension length 50 P ,- - Extension length 100 P ,- - Extension length 150 P ,- - Extension ade of Hastelloy C Extension length 50 P ,- + 4 wks Extension length 100 P ,- + 4 wks Extension length150 P ,- + 4 wks Filling liquid 1) Silicone oil Carbon fluoride ,- - White oil (suitable for the use in the food and beverage industry) ,- - High-teperature oil (not for 'close coupled to sensor' design, Code-No. 699) ,- + 4 wks Vacuuproof design (is always necessary with 2020TA) ,- + 4 wks Lengths of capillary tube , , , , , , ,- - Special length between 1 and 16 Basic price of the next longer standard length plus an extra fee ,- - Special features Diaphrag with FEP-coating 2) ,- + 6 wk s (for aterial 316L (1.4404) and Hast. C; ediu teperature < 150 / 302 F) Capillary tube with PVC protective cover 775 8,-/ - Other variations regarding pressure rating, aterial, sealing surface, filling liquid on request For ounting fro reote seals in "sandwich construction" (additional blank flange required) see data sheet EN. The three-digit code nubers are added to the order nuber, separated by diagonal strokes. 1) When ounted on an absolute or gauge pressure transitter for easureent < 500 (abs,), the vacuuproof design ust be ordered (Code.No. 739). 2) With "extended diaphrag" on request Page 11 of 21

12 Flush diaphrag seal / Extended diaphrag seal DN 80 / DN 3 (coplete with flange) Options Code-No. EUR Delivery Reote seal ounting Directly ounted (without capillary tube) Connection to sensor with capillary tube Noinal diaeter Sealing surface Diaphrag / sealing DN 80 For E (DIN 2526) 316 L st.st. (1.4404) P ,- + 1 wk Hastelloy C P ,- + 2 wks Tantalu P ,- + 2 wks For V 13 (DIN 2513) 316 L st.st. (1.4404) P ,- + 1 wk Hastelloy C P ,- + 2 wks Tantalu P ,- + 3 wks For N (DIN 2512) 316 L st.st. (1.4404) P ,- + 1 wk Hastelloy C P ,- + 3 wks Tantalu P ,- + 3 wks DN 3" For RF (ANSI B 16.5) 316 L st.st. (1.4404) P ,- + 1 wk Hastelloy C P ,- + 2 wks Tantalu P ,- + 3 wks Flange / Pressure rating DN 80 PN 16 / 40 P PN 64 diaph. Tantalu on request P ,- - PN 100 diaph. Tantalu on request P ,- - ANSI 3" Class 150 psi only sealing RF P Class 300 psi only sealing RF P ,- - Class 600 psi only sealing RF, diaph. Tantalu on request P ,- - Flush diaphrag / extended diaphrag Reote seal with flush diaphrag (without extension) P Reote seal with extension (not cobineable with diaphrag aterial "Tantalu") DN 80 / 3" Extension ade of 316 L st.st. Extension length 50 P ,- - Extension length 100 P ,- - Extension length 150 P ,- - Extension ade of Hastelloy C Extension length 50 P ,- + 4 wks Extension length 100 P ,- + 4 wks Extension length150 P ,- + 4 wks Filling liquid 1) Silicone oil Carbon fluoride ,- - White oil (suitable for the use in the food and beverage industry) ,- - High-teperature oil (not for 'close coupled to sensor' design, Code-No. 699) ,- + 4 wks Vacuuproof design (is always necessary with 2020TA) ,- + 4 wks Lengths of capillary tube , , , , , , ,- - Special length between 1 and 16 Basic price of the next longer standard length plus an extra fee ,- - Special features Diaphrag with FEP-coating 2) ,- + 6 wks (for aterial 316L (1.4404) and Hast. C; ediu teperature < 150 / 302 F) Capillary tube with PVC protective cover 775 8,-/ - Other variations regarding pressure rating, aterial, sealing surface, filling liquid on request For ounting fro reote seals in "sandwich construction" (additional blank flange required) see data sheet EN. The three-digit code nubers are added to the order nuber, separated by diagonal strokes. 1) When ounted on an absolute or gauge pressure transitter for easureent < 500 (abs,), the vacuuproof design ust be ordered (Code.No. 739). 2) With "extended diaphrag" on request. Page 12 of

13 In-line reote seal DN DN Options Code-No. EUR Delivery Reote seal ounting 1) Directly ounted (without capillary tube) Connection to sensor with capillary tube Pressure rating PN 6...PN 400 or Class 150 psi...class 2500 psi Connection acc. to DIN 2501 or ANSI B 16.5 Diaphrag and sealing surface ade of 316 Ti st.st. (1.4571) Noinal diaeter Sealing surface DN 25 / ANSI 1" For E (DIN 2526) / For RF ,- + 2 wks DN 40 / ANSI 1 1/2" For E (DIN 2526) / For RF ,- + 2 wks DN 50 / ANSI 2" For E (DIN 2526) / For RF ,- + 2 wks DN 80 / ANSI 3" For E (DIN 2526) / For RF ,- + 2 wks Diaphrag and sealing surface ade of Hastelloy C Noinal diaeter Sealing surface DN 25 / ANSI 1" For E (DIN 2526) / For RF ,- + 3 wks DN 40 / ANSI 1 1/2" For E (DIN 2526) / For RF ,- + 3 wks DN 50 / ANSI 2" For E (DIN 2526) / For RF ,- + 3 wks DN 80 / ANSI 3" For E (DIN 2526) / For RF ,- + 3 wks Filling liquid 1) Silicone oil Carbon fluoride ,- - White oil (suitable for the use in the food and beverage industry) ,- - High-teperature oil (not for direct ounting, Code-No. 699) ,- + 4 wks Vacuuproof design (is always necessary with 2020TA) ,- + 4 wks Length of capillary tube , ,- - 4 (axial length with DN 25 / ANSI 1") ,- - 6 (axial length with DN 40 / ANSI 1 1/2") ,- - 8 (axial length with DN 50 / ANSI 2") , , (axial length with DN 80 / ANSI 3") ,- - Special length between 1 and 6 Basic price of the next longer standard length plus an extra fee ,- - Special features Capillary tube with PVC protective cover ,-/ - Other variations regarding pressure rating, aterial, sealing surface, filling liquid on request The three-digit code nubers are added to the order nuber, separated by diagonal strokes. 1) When ounted on an absolute or gauge pressure transitter for easureent < 500 (abs,), the vacuuproof design ust be ordered (Code.No. 739) Page 13 of 21

14 Fast coupled reote seals DN 50 / DN 2 Options Code-No. EUR Delivery Reote seal ounting 1) Directly ounted (without capillary tube) with Running Union acc. to DIN Noinal diaeter Pressure rating Process wetted parts DN 50 PN Ti st.st. (1.4571) ,- + 2 wks DN 50 PN 25 Hastelloy C ,- + 2 wks with Clap connection Noinal diaeter Pressure rating Process-wetted parts ANSI 2" PN Ti st.st. (1.4571) ,- + 2 wks ANSI 2" PN 40 Hastelloy C ,- + 2 wks Sealing ring (O-ring) (only in conjunction with running union acc. to DIN ) Buna (Tax. 120 ) PTFE ,- - Filling liquid 1) Silicone oil Carbon fluoride ,- - White oil (suitable for the use in the food and beverage industry) ,- - Vacuuproof design (is always necessary with 2020TA) ,- + 3 wks Other variations regarding pressure rating, aterial, sealing surface, filling liquid on request The three-digit code nubers are added to the order nuber, separated by diagonal strokes. 1) When ounted on an absolute or gauge pressure transitter for easureent < 500 (abs.), the vacuuproof design ust be ordered (Code.No. 739). Miniature Reote Seal Options Code-No. EUR Delivery Reote seal ounting 1) Direct ounting (without capillary tube) with Spigot acc. to DIN Process connection Pressure rating Process-wetted parts G 1 A PN Ti st.st. (1.4571) ,- + 3 wks G 1 A PN 600 Hastelloy C ,- + 3 wks G 1 1/2 A PN Ti st.st. (1.4571) ,- + 3 wks G 1 1/2 A PN 600 Hastelloy C ,- + 3 wks Filling liquid 1) Silicone oil Carbon fluoride ,- - White oil (suitable for the use in the food and beverage industry) ,- - Vacuuproof design ,- + 4 wks Other variations regarding pressure rating, aterial, sealing surface, filling liquid on request The three-digit code nubers are added to the order nuber, separated by diagonal strokes. 1) When ounted on an absolute or gauge pressure transitter for easureent < 500 (abs.), the vacuuproof design ust be ordered (Code.No. 739). Page 14 of

15 Questionnaire 80/ EN (page 1 of 2) Location Measuring instruents with reote seals for easuring gauge pressure, differential pressure, flowrate and level The inforation given in this questionnaire is binding for the technical design of easuring syste. Only when exact and correct inforation is provided it can be ensured satisfactory easureent results. The questions identfied by will be answered by. Copany Custoer nuber: Measuring-point nuber: Level Measureent Offer nuber: Contract nuber: Position nuber: 1 Mediu to be easured Measuring instruent with one reote seal (see Fig. 1) Measuring instruent with two reote seals (see Fig. 2) Operating data of the ediu to be easured which will be referred to for the calculation and design Teperatures Process pressure Density Density of the gas above the process Process variable (e.g A) Elevation between reote seal and easuring instr. Instruent above the reote seal Instruent below the reote seal Difference in elevation of the two reote seals Tank diensions: Difference in height of levels Diension: fro lower reote seal up to lower level fro lower reote seal up to upper level Capillary tube length + (HP) side (LP) side Additional data Process teperature range Average abient teperature at the easuring instr. Average abient teperature at the capillary tube t a a c b d M + t M t um t uk kg/ 3 0/4...20A) t p e c b d M G fro... to... t M fro... to... t um t uk kg/ 3 kg/ 3 0/4...20A) 8 Data of liits which for exaple can occur with cleaning processes or blowing through (not easuring operation) Teperature Pressure t ax t in pax pin t ax t in pax pin Note: Reote seals with silicone oil (standard) ay be ounted up to a axiu of 5 below the easuring instruent. Measuring instruent Fig. 1 Fig. 2 Reote seal H 2 Measuring H 2 instruent H 1 lower level H 2 upper level a+ 0 a c H 1 H 1 b d Reote seal Tank open to the atosphere Reote seal c b d e Pressuretight closed tank M01281E2.eps Page 15 of 21

16 Questionnaire 80/ EN (page 2 of 2) Gauge pressure, Differential pressure and Flowrate Measureent 1 Mediu to be easured Measuring instruent with one reote seal (see Fig. 3) Measuring instruent with two reote seals (see Fig. 4) Operating data of the ediu to be easured which will be referred to for the calculation and design Teperatures Process pressure Measuring span Differential pressure Density of the gas above the process Process variable (e.g A) Elevation between reote seal and easuring instr. Instruent above the reote seal Instruent below the reote seal Difference in elevation of the two reote seals 5 Capillary tube length + (HP) side (LP) side 6 Additional data Process teperature range Average abient teperature at the easuring instr. Average abient teperature at the capillary tube t p a a M M + t M fro... to... t um t uk kg/ 3 0/4...20A t p1 p2 M pp 1 p 2 M e t M fro... to... t um t uk kg/ 3 0/4...20A 7 Data of liits which for exaple can occur with cleaning processes or blowing through (not easuring operation) Teperature Pressure t ax t in pax pin t ax t in pax pin Note: Reote seals with silicone oil (standard) ay be ounted up to a axiu of 5 below the easuring instruent. Measuring instruent Fig. 3 Fig. 4 Reote seal p 2 h+ Measuring instruent 0 p 1 e Piping h Reote seal Piping p 1 Measuring instruent Reote seal e.g. also with filter easureents; in front of and behind the filter Copiled:, Date 20 Copany stap (Signature) M01282E2.eps Page 16 of

17 Diensional drawings Construction Transitter with rel-type aplifier housing Errors and oissions excepted. Diensions are in 8 5 Connections on this side ~114 9 ~ with LCD indicator 20 clearance for cover reoval required 191 A) space ust be available to rotate the keyboard cover 124 ~ ~42 Ø83 1 Reote seal connection 2 Electrical connections: M20x1.5 cable gland or 1/2-14 NPT feale threads on both sides or one plug Han 8U 3 Type plate 4 Captive screw for key unit cover 5 Housing rotation stop screw 6 Blind plug 7 Enclosure cover 8 Tie-on plate, e.g. for tag nuber (option) 9 Plate, also with key legend A) With directly connected reote seal, the length (height) of the reote seal ust be added to the entioned diension (see corresponding diensional drawing). M01513x1_en.eps Page 17 of 21

18 Diensional drawings Transitter with DIN-type aplifier housing Errors and oissions excepted. Diensions are in. 70 space ust be available to rotate the keyboard cover ~ ~ with LCD indicator 20 clearance for cover reoval required (* Silicone pressure sensor) 191 A) 136 ( 140*) (16*) ~ ~48 ~ clearance for cover reoval required 4 Ø83 Connections On this side 9 ~130 A) With directly connected reote seal, the length (height) of the reote seal ust be added to the entioned diension (see corresponding diensional drawing). 3 1 Reote seal connection 2 Electrical connections: M20x1.5 cable gland or 1/2-14 NPT feale threads on both sides or one plug Han 8U 3 Type plate 4 Captive screw for key unit cover 5 Housing rotation stop screw 6 Blind plug 7 Enclosure cover 8 Tie-on plate, e.g. for tag nuber (option) 9 Plate, also with key legend 10 T-slot for screws when wall or pipe ounting M01512x1_en.eps Page 18 of

19 Diensional drawings Sealing rings and fixing aterials not supplied! Directly Connected Mounting with Capillary Tube Flush diaphrag reote seals Flush diaphrag reote seals b ød2 ød3 ø k ø D t MA1389X1.eps Extended diaphrag reote seals M01391X1.tif Extended diaphrag reote seals L () 50/100/150 b ød1 ød3 øk ød MA1390X1.eps For V13 Sealing Surface b M01392X1.tif Sealing Surfaces: For E (DIN 2526), For N (DIN 2512), For RF (ANSI B16.5) Optionally directly connected Noinal diaeter DN Pressure rating PN ød ø k Extension ø d 1 ø d 2 ø d 3 t b Nuber Screws Thread PN 16/ M 16 Capillary tube 50 PN M / 87 (DN 80/50) 2 ød 80 PN M 20 PN 16/ M 16 PN M 20 PN M 24 class M 18 2" class M 18 class M 18 class M 16 3" class M 20 MA1394X1_en.eps class M Page 19 of 21

20 b 2020TG / 2020TA with reote seal Diensional drawings Flush Diaphrag Reote Seals DN 25 / DN 1 with internal Diaphrag PN 10/40 or Class 150 / 300 Miniature Reote Seals Optionally directly connected d 2 DN k D PN or Class 600 / 1500 d d 4 2 M01388X1_en.eps effective diaphrag diaeter d M SW width across flats flexible capillary tube possible b f SW l h d M G d M01117X1.eps Diensions in DN Weight PN (G) d in kg M SW d l h G 1A G 1 1/2A H ±1 28 DN G 2 d 4 k D M01116X2_en.eps Connections to DIN 2501 DN PN Diensions in D k d 4 b f H d 2 G 2 Weight in kg 25 10/ / xM xM xM Connections to ANSI B 16.5 DN Class Diensions in D k d 2 d 4 b f H G 2 UNC Weight in kg 1" 1" x5/8" x7/8" 4.0 Page 20 of

21 Diensional drawings In-Line Reote Seals (without flanges) Flexible capillary tube possible Fast Coupled Reote Seals with Running Union DN 50, PN ax 25 L 15_0008x1_en.eps Connection acc. to DIN 2501 / acc. ANSI B 16.5 Connection acc. to DIN DN in / inch PN in / psi Diensions in D L Mb Weight in kg Diensions in d M D H approx. k G 2 Design Weight in kg 25 / / Rd 78 x 1/6 For D-F / 1 1/ / / / / / / with Clap-connection DN 2, PN ax 40 D 38 H h d M DN 56,3 MA1120X1.eps Diensions in d M D H approx. h approx. Weight in kg effective diaphrag diaeter d M Page 21 of 21

22 ABB Ltd. Howard Road, St. Neots Cabridgeshire, PE19 8EU UK Tel.: +44 (0) Fax: +44 (0) ABB Inc. 125 E. County Line Road Warinster, PA USA Tel.: Fax: ABB Autoation Products GbH Schillerstraße 72 D Minden Gerany Tel.: Fax: Subject to technical changes Printed in the Fed. Rep. of Gerany 10/ EN 04.03

Contrans P HART Transmitter

Contrans P HART Transmitter Contrans P HART Transitter ASD 800 / 810 with Reote Seal for Gauge / Absolute Pressure and Level Span: 60 to 600 (16 abs) (6 kpa to 60,000 kpa) (6 kpa to 1,600 kpa abs) 10/ (624.bp) n Isolation between

More information

Multi Vision. Digital Transmitter 10/ EN

Multi Vision. Digital Transmitter 10/ EN Multi Vision Digital Transmitter 2010TD for Differential Pressure, Flow Rate and Level Spans: 50 Pa... 10 MPa (0.2 in. H 2 O...1500 psi) 2 kpa... 2 MPa abs. (8 in. H 2 O... 300 psia) 2010TDSW.TIF Measured

More information

2600T Series Pressure Transmitter Models 264DC Differential and 264HC Gage Level Transmitters. Kent-Taylor

2600T Series Pressure Transmitter Models 264DC Differential and 264HC Gage Level Transmitters. Kent-Taylor INDUSTRIAL INSTRUMENTS AND CONTROLS SPECIALIST Kent-Taylor 2600T Series Pressure Transmitter Models 264DC Differential and 264HC Gage Level Transmitters Features Include Base accuracy : ±0.075% Span limits

More information

Torque Tube TB300 Digital Transmitters

Torque Tube TB300 Digital Transmitters Page 1 of 7 7E.300-E Issue 4-2009 Description Series TB300 torque tube liquid level instruments utilize the buoyancy exerted on a displacer when immersed in a liquid. The buoyancy on the displacer is proportional

More information

S265 Remote seals with capillary tube. 2600T Series Pressure Transmitters. Engineered solutions for all applications

S265 Remote seals with capillary tube. 2600T Series Pressure Transmitters. Engineered solutions for all applications Contents Data Sheet S265 2600T Series Pressure Transmitters Engineered solutions for all applications Wide range of remote seal types Allows optimum design for each application without compromising performance

More information

Level transmitter LT 100

Level transmitter LT 100 KROHNE 09/2001 7.02363.21.00 GR/PRINTO Level transmitter LT 100 Status: 10/99 Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass flowmeters

More information

2600T Series Pressure Transmitter

2600T Series Pressure Transmitter Data Sheet 2600T Series Pressure Transmitter Model 261GC/GG/GJ/GM/GN Gauge Model 261AC/AG/AJ/AM/AN Absolute with direct mount seal Base accuracy: ±0.15 % Span limits 0.3 to 60000kPa; 1.2inH 2 O to 8700psi

More information

1 Overview. Pressure Measurement Transmitters for basic requirements. 1/16 Siemens FI SITRANS P220 for gauge pressure

1 Overview. Pressure Measurement Transmitters for basic requirements. 1/16 Siemens FI SITRANS P220 for gauge pressure Siemens AG 204 Overview The pressure transmitter SITRANS P220 measures the gauge pressure of liquids, gases and vapors. Stainless steel measuring cell, fully welded Measuring ranges 2.5 to 600 bar (36.3

More information

SITRANS P measuring instruments for pressure

SITRANS P measuring instruments for pressure SITRANS P measuring instruments for pressure Z series for gage pressure Siemens AG 008 Overview Design The main components of the pressure transmitter are: Brass housing with silicon measuring cell and

More information

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS Electropneumatic Positioner and Pneumatic Positioner Type 3760 Application Single-acting positioners for direct attachment to pneumatic control valves. Supplied with an electric input signal of 4 to 20

More information

Model 261GR for gauge pressure Model 261AR for absolute pressure

Model 261GR for gauge pressure Model 261AR for absolute pressure Change from one to two columns Data Sheet SS/261GR/AR-EN Rev. 07 Model 261GR for gauge pressure Model 261AR for absolute pressure 2600T series pressu re transmitters Engineered solutions for all applications

More information

L (up to 25 m) Electronic part. working temp.: Ñ IP 66 / IP67. Mounting bracket ÐÑ. Sensor type. working temp.:

L (up to 25 m) Electronic part. working temp.: Ñ IP 66 / IP67. Mounting bracket ÐÑ. Sensor type. working temp.: Smart level probe type APC-2000ALW/L Programmable zero shift, range and damping ratio 4...20 ma output signal + HART protocol Accuracy 0,16% Local display Intrinsic safety certificate (ATEX, IECEx) II

More information

9700 Transmitter Submersible hydrostatic level transmitter

9700 Transmitter Submersible hydrostatic level transmitter Specification sheet IP0078 October 2007 Level 9700 Transmitter Submersible hydrostatic level transmitter Description The 9700 series hydrostatic level transmitter is designed to perform in the most arduous

More information

Siemens AG psi (6 bar) 145 psi (10 bar) 464 psi (32 bar) 1450 psi (100 bar) 3626 psi (250 bar) 8700 psi (600 bar) psi (800 bar)

Siemens AG psi (6 bar) 145 psi (10 bar) 464 psi (32 bar) 1450 psi (100 bar) 3626 psi (250 bar) 8700 psi (600 bar) psi (800 bar) Technical specifications SITRANS P, DS III series Input Measured variable Spans (infinitely adjustable) or nominal measuring range and max. permissible test pressure HART Gauge pressure Span (min.... max.)

More information

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure Z series for gage pressure Overview Design The main components of the pressure transmitter are: Brass housing with silicon measuring cell and electronics plate Process connection Electrical connection

More information

Pressure Measurement Single-range transmitters for general applications

Pressure Measurement Single-range transmitters for general applications Siemens A 207 Overview Application The SITRANS P Compact pressure transmitter is designed for the special requirements of the food, pharmaceutical and biotechnology industries. The use of high-grade materials

More information

Differential Pressure Transmiter

Differential Pressure Transmiter Differential Pressure Transmiter Description The is an economical alternative to established differential pressure transmitters. It combines state of the art electronics and a high performance sensor;

More information

Electropneumatic Positioner Type 4763 Pneumatic Positioner Type 4765

Electropneumatic Positioner Type 4763 Pneumatic Positioner Type 4765 Electropneumatic Positioner Type 4763 Pneumatic Positioner Type 4765 Application Single-acting positioner for attachment to pneumatic control valves. Supplied with either an electric input signal from

More information

Differential pressure

Differential pressure Differential pressure 9 Overview Page 200 VEGADIF 65 Page 202 Chemical seal Page 204 Accessory Page 208 199 VEGADIF For differential pressure, level and flow measurements Measuring principle The sensor

More information

Liquid level instruments BM 24 /BM 51

Liquid level instruments BM 24 /BM 51 KROHNE 09/2001 7.02362.21.00 GR/PRINTO Liquid level instruments / Status: 10/99 Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass flowmeters

More information

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/16 Siemens FI US Edition

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/16 Siemens FI US Edition Siemens AG 206 Overview Design Device structure without explosion protection The pressure transmitter consists of a piezoresistive measuring cell with a diaphragm installed in a stainless steel enclosure.

More information

LMP 307. Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % / 0.

LMP 307. Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % / 0. LMP 07 Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % / 0. % FSO Nominal pressure from 0... mho up to 0... 50 mho Output signals -wire: 4... 0 ma -wire: 0...

More information

Pressure Measurement. Transmitters for basic requirements SITRANS P Z for gauge pressure. 2/4 Siemens FI Overview

Pressure Measurement. Transmitters for basic requirements SITRANS P Z for gauge pressure. 2/4 Siemens FI Overview f gauge pressure Siemens AG 010 Overview Design The main components of the pressure transmitter are: Brass housing with silicon measuring cell and electronics plate Process connection Electrical connection

More information

Pressure Measurement Single-range transmitters for general applications

Pressure Measurement Single-range transmitters for general applications Siemens AG 206 Overview Design Device structure without explosion protection The pressure transmitter consists of a piezoresistive measuring cell with a diaphragm installed in a stainless steel enclosure.

More information

Type N-10, N-11 Hazardous Area Non-incendive Transmitters

Type N-10, N-11 Hazardous Area Non-incendive Transmitters Electronic Pressure Catalog > Hazardous Area > N-10, N-11 Type N-10, N-11 Hazardous Area Non-incendive Transmitters Applications Natural gas compressors Wellhead monitoring Pipeline pressure General industrial

More information

IDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

IDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05 IDL0 Battery Powered Precision Digital Gauge for Leak Testing Stainless Steel Sensor class 0.05 Nominal pressure from 0 00 mbar up to 0... 00 bar Special characteristics modular sensor concept data logger

More information

S261 Remote seals with capillary tube

S261 Remote seals with capillary tube Contents Data Sheet SS/S261EN Rev. 0 S261 2600T Series Pressure Transmitters Engineered solutions for all applications Measurement made easy Wide range of remote seal types llows optimum design for each

More information

GA24 Technical Datasheet

GA24 Technical Datasheet GA24 Technical Datasheet Variable-area flowmeter Sturdy construction for several applications Local indication without auxiliary power Replaceable mounting parts KROHNE CONTENTS GA24 1 Product features

More information

Hydrostatic. Continuous level measurement. Overview Page 188 VEGAWELL 52 Page 190 VEGABAR 86, 87 Page 192 Accessory Page 196 AL-EN

Hydrostatic. Continuous level measurement. Overview Page 188 VEGAWELL 52 Page 190 VEGABAR 86, 87 Page 192 Accessory Page 196 AL-EN Hydrostatic Continuous level measurement 8 Overview Page 188 VEGAWELL 52 Page 190 VEGABAR 86, 87 Page 192 Accessory Page 196 187 Hydrostatic Level and pressure measurement Measuring principle The pressure

More information

OPTIBAR P 1010 C Technical Datasheet

OPTIBAR P 1010 C Technical Datasheet Technical Datasheet Pressure transmitter with recessed diaphragm for general applications Wide variety thanks to modular design Measuring ranges up to 250 bar / 3750 psi High overload and temperature stability

More information

SITRANS. Pressure transmitter SITRANS P, Z series for gauge and absolute pressure. Introduction. Safety instructions 2.

SITRANS. Pressure transmitter SITRANS P, Z series for gauge and absolute pressure. Introduction. Safety instructions 2. Introduction 1 Safety instructions 2 SITRANS Pressure transmitter SITRANS P, Z series for gauge and absolute pressure 7MF1564 Description 3 Assembly and connection 4 Technical data 5 Dimensional drawings

More information

High-performance submersible pressure transmitter For level measurement Model LH-10

High-performance submersible pressure transmitter For level measurement Model LH-10 Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-10 WIKA data sheet PE 81.09 Applications Level measurement in rivers and lakes Deep well

More information

ATM.1ST/Ex - High Precision Transmitter

ATM.1ST/Ex - High Precision Transmitter Pressure Transmitter - ATEX / IECEx certified ATM.1ST/Ex - High Precision Transmitter CUSTOMER BENEFITS Certificate: ATEX, IECEx & EAC High measurement accuracy is ensured by sophisticated digital temperature

More information

High-performance submersible pressure transmitter For level measurement Model LH-20

High-performance submersible pressure transmitter For level measurement Model LH-20 Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-20 WIKA data sheet PE 81.56 Applications Deep well and borehole measurements Groundwater

More information

ATM.ECO/IS - Analog Transmitter with Temperature compensation

ATM.ECO/IS - Analog Transmitter with Temperature compensation Pressure Transmitter - FM / FM-C certified ATM.ECO/IS - Analog Transmitter with Temperature compensation CUSTOMER BENEFITS Certificate: FM, FM-C & IECEx & ATEX Entry level series into precision pressure

More information

MXV-E. Variable Speed Multi-Stage Vertical Pumps (max 2900 rpm)

MXV-E. Variable Speed Multi-Stage Vertical Pumps (max 2900 rpm) Variable Speed Multi-Stage Vertical Pups (ax 9 rp) Construction Vertical ulti-stage pups with suction and delivery connections of the sae diaeter and arranged along the sae axis (in-line). Corrosion-resistant

More information

DM01. Please visit our website: Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

DM01. Please visit our website:  Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05 DM0 Battery Powered Stainless Steel Sensor class 0.05 Nominal pressure from 0 00 mbar up to 0... 00 bar Special characteristics modular sensor concept data logger graphic display stainless steel housing

More information

High-performance submersible pressure transmitter For level measurement Model LH-20

High-performance submersible pressure transmitter For level measurement Model LH-20 Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-20 WIKA data sheet PE 81.56 Applications Deep well and borehole measurements Groundwater

More information

Technical Datasheet. D Series SMART Pressure Transmitter Model: DPC D-Series. Key Features. Series Overview. Product applications

Technical Datasheet. D Series SMART Pressure Transmitter Model: DPC D-Series. Key Features. Series Overview. Product applications Technical Datasheet D Series SMART Pressure Transmitter Model: DPC-2000 Key Features ATEX - Flameproof and Intrinsically Safe IECEx - Flameproof and Intrinsically Safe SIL 2 certificate Compliant to NAMUR

More information

Technical Data. General specifications Switching element function Rated operating distance s n 2 mm

Technical Data. General specifications Switching element function Rated operating distance s n 2 mm 0102 Model Number Features 2 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories EXG-12 Quick mounting bracket with dead stop BF 12 Mounting flange, 12 mm Technical Data specifications Switching

More information

Dimensions. Technical Data General specifications Switching element function Rated operating distance s n 10 mm

Dimensions. Technical Data General specifications Switching element function Rated operating distance s n 10 mm Dimensions M30x1,5 5 40 37 0102 Model Number 36 LED Features Comfort series 10 mm embeddable Connection BN BU Accessories BF 30 Mounting flange, 30 mm L+ L- Technical Data specifications Switching element

More information

C-Flow Coriolis Mass Flow Meters

C-Flow Coriolis Mass Flow Meters Coriolis Mass Flow Meters Ready for Take Off The New Compact C-Flow Küppers Elektromechanik GmbH The C-Flow The C-Flow Coriolis Mass Meters consist of two components: KCE Transmitter KCM Transducer 2 KEM

More information

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05 Battery Powered Stainless Steel Sensor class 0.05 Nominal pressure from 0 00 mbar up to 0... 00 bar Special characteristics modular sensor concept data logger graphic display stainless steel housing Ø

More information

x act i Precision- Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor

x act i Precision- Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor Precision- Pressure Transmitter for Food ndustry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to EC 60770: 0. % FSO Nominal pressure from 0... 400 mbar up to 0... 40 bar Output

More information

UNIK 5600/5700 Marine Certified Pressure Sensing Platform

UNIK 5600/5700 Marine Certified Pressure Sensing Platform GE Measurement & Control UNIK 5600/5700 Marine Certified Pressure Sensing Platform The new UNIK 5600/5700 carries marine certification for most zones on-board ship, as well as Intrinsically Safe certifications.

More information

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0. Precision Pressure Transmitter for Food ndustry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to EC 60770: 0. % FSO Nominal pressure from 0... 400 mbar up to 0... 40 bar Output

More information

ETd 04. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. Type: ETd 04. class 0.05

ETd 04. Battery Powered Precision Digital Gauge. Stainless Steel Sensor.  Type: ETd 04. class 0.05 Battery Powered Stainless Steel Sensor class 0.05 Nominal pressure from 0 100 mbar up to 0... 400 bar Special characteristics modular sensor concept data logger graphic display stainless steel housing

More information

Pressure Measurement Single-range transmitters for general applications

Pressure Measurement Single-range transmitters for general applications Siemens AG 07 Overview Function U const. p U I EM Sensor Connection for auxiliary power supply Vent pipe with humidity filter Protective conductor connection/ Equipotential bonding Diaphragm The pressure

More information

Technical Data. General specifications. Rated operating distance s n 5 mm

Technical Data. General specifications. Rated operating distance s n 5 mm 0102 Model Number Features 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories EXG-18 Quick mounting bracket with dead stop BF 18 Mounting flange, 18 mm Technical Data specifications Switching

More information

DMK 458. Pressure Transmitter for Marine and Offshore. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.25 % FSO option: 0.

DMK 458. Pressure Transmitter for Marine and Offshore. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.25 % FSO option: 0. Pressure Transmitter for Marine and Offshore Ceramic Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0. % FSO Nominal pressure from 0... 40 mbar up to 0... 0 bar Output signals -wire:

More information

High-performance submersible pressure transmitter For level measurement in hazardous areas Model LH-20

High-performance submersible pressure transmitter For level measurement in hazardous areas Model LH-20 Electronic pressure measurement High-performance submersible pressure transmitter For level measurement in hazardous areas Model LH-20 WIKA data sheet PE 81.56 Applications Deep well and borehole measurements

More information

Pressure transmitter PASCAL Ci4

Pressure transmitter PASCAL Ci4 Pressure transmitter PASCAL Ci4 for general application,type Series CI4100 Features Pressure transmitter for the measuring of relative and absolute pressures of gases, vapors and liquids High-resolution

More information

Model NDA Differential pressure transmitter. Deltapi N Series A complete range of pneumatic pressure transmitters

Model NDA Differential pressure transmitter. Deltapi N Series A complete range of pneumatic pressure transmitters Data Sheet DS/NDA-EN Rev. H Model NDA Differential pressure transmitter Deltapi N Series A complete range of pneumatic pressure transmitters Introduction The blind type differential pressure transmitter

More information

MXV. Vertical Multi-Stage In-Line Pumps. Construction. Applications

MXV. Vertical Multi-Stage In-Line Pumps. Construction. Applications MXV Construction Vertical ulti-stage pups with suction and delivery connections of the sae diaeter and arranged along the sae axis (in-line). Corrosion-resistant bearing sleeves lubricated by the puped

More information

High-performance submersible pressure transmitter For level measurement Model LH-20

High-performance submersible pressure transmitter For level measurement Model LH-20 Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-20 WIKA data sheet PE 81.56 Applications Deep well and borehole measurements Groundwater

More information

Technical Data. Dimensions

Technical Data. Dimensions 00 Model Number Features mm flush Usable up to SIL acc. to IEC 6508 Accessories V-G Female connector, M, -pin, field attachable V-W Female connector, M, -pin, field attachable V-G-N-M-PUR Female cordset,

More information

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS Electropneumatic Positioner and Pneumatic Positioner Type 3760 Application Single-acting positioners for direct attachment to pneumatic control valves. An electric standardized signal of 4 to 20 ma or

More information

Precision pressure sensor Basic version Model CPT6020

Precision pressure sensor Basic version Model CPT6020 Calibration Precision pressure sensor Basic version Model CPT6020 WIKA data sheet CT 25.13 Applications Calibration technology High-accuracy pressure monitoring Pressure sensing in critical applications

More information

NivuBar Plus II

NivuBar Plus II NivuBar Plus II Ceramic diaphragm Capacitive measuring cell 2-wire technology (output 4-20 ma) Integrated overload protection Extensive, almost front flush diaphragm Ex approval for zone 0 as standard

More information

Technical Data Sheet. OPTIMASS 7000 Custody Transfer Mass Flowmeter

Technical Data Sheet. OPTIMASS 7000 Custody Transfer Mass Flowmeter Technical Data Sheet KROHNE 12/2004 7.02516.21.00 CH/GR OPTIMASS 7000 Custody Transfer Mass Flowmeter with single straight measuring tube OIML R117 Pattern Approval Accuracy classes 0.3 / 0.5 / 1.0 / 1.5

More information

Programmable pressure and temperature transmitters PTM/RS485

Programmable pressure and temperature transmitters PTM/RS485 Programmable pressure and temperature transmitters PTM/RS485 Version: 03-28-2012 Technical Specifications Pressure measuring range (bar) 0.1... 0.5 > 0.5 2 > 2 25 Overpressure 3 bar 3 x FS ( 3 bar) 3 x

More information

JUMO dtrans p30 Pressure Transmitter

JUMO dtrans p30 Pressure Transmitter 609 Fulda, Germany Postal address: 605 Fulda, Germany Phone: +49 661 600-0 Fax: +49 661 600-607 Phone: +44 179 6 55 Data Sheet 40466 Page 1/6 JUMO dtrans p0 Pressure Transmitter General application Pressure

More information

3000 Series OPTIMASS Mass Flowmeter. Stainless Steel Hastelloy

3000 Series OPTIMASS Mass Flowmeter. Stainless Steel Hastelloy KROHNE 07/2005 7.02446.25.00 GR 3000 Series OPTIMASS Mass Flowmeter with single Z-shaped measuring tube Stainless Steel Hastelloy Status: 10/99 One tube no limits No limits with tube material No limits

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features 2 mm flush Usable up to SIL2 acc. to IEC 61508 Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 2 mm Installation flush Output

More information

Series INTELLIGENT PRESSURE- AND LEVEL TRANSMITTERS For all industries. Description ALL STAINLESS DESIGN

Series INTELLIGENT PRESSURE- AND LEVEL TRANSMITTERS For all industries. Description ALL STAINLESS DESIGN INTELLIGENT PRESSURE- AND LEVEL TRANSMITTERS For all industries Series 2000 ALL STAINLESS DESIGN EASY CALIBRATION WITHOUT TEST PRESSURE BY 3 PUSH BUTTONS ACCURACY 0,1% 4-20 ma AND HART PROTOCOL ATEX II

More information

Miniature flowmeters DK 46, DKR 46 DK 47, DK 48, DK 800

Miniature flowmeters DK 46, DKR 46 DK 47, DK 48, DK 800 KROHNE 1/22 7.236.22. GR Miniature flowmeters DK 46, DKR 46 DK 47, DK 48, DK 8 Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass flowmeters

More information

Pressure Measurement Transmitters for applications with advanced requirements (Advanced)

Pressure Measurement Transmitters for applications with advanced requirements (Advanced) Siemens AG 207 Technical specifications SITRANS P DS III series for absolute pressure (from the gauge pressure series) Input Measured variable Absolute pressure Span (fully adjustable) or measuring range,

More information

Gas density monitor With integrated transmitter Model GDM-100-TI

Gas density monitor With integrated transmitter Model GDM-100-TI SF 6 gas solutions Gas density monitor With integrated transmitter Model GDM-100-TI grid Products WIKA data sheet SP 60.05 for further approvals see page 5 Applications Gas density monitoring of closed

More information

Level switches Series LD Vibrating fork level switch for liquids and solids

Level switches Series LD Vibrating fork level switch for liquids and solids Level switches Series LD Vibrating fork level switch for liquids and solids Robust and compact Suitable for liquids (model LD61) and solids (model LD60) No moving parts, low maintenance Corrosion resistant

More information

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI Siemens AG 06 SITRANS LH00 Transmitter for hydrostatic level Overview Function U const. p U I EM The pressure transmitter SITRANS LH00 is a submersible sensor for hydrostatic level measurement. The pressure

More information

Programmable pressure and temperature transmitters PTM/RS485

Programmable pressure and temperature transmitters PTM/RS485 Programmable pressure and temperature transmitters PTM/RS485 Version: 26.06.2014 Technical Specifications Pressure measuring range (bar) 0.1... 0.5 > 0.5 2 > 2 25 Overpressure 3 bar 3 x FS ( 3 bar) 3 x

More information

Level switches Series LD Vibrating fork level switch for liquids and solids

Level switches Series LD Vibrating fork level switch for liquids and solids Level switches Series LD Vibrating fork level switch for liquids and solids Robust and compact Suitable for liquids (model LD61) and solids (model LD60) No moving parts, low maintenance Corrosion resistant

More information

Parametrable / Programmable Pressure Transmitter

Parametrable / Programmable Pressure Transmitter Parametrable / Programmable Pressure Transmitter PTM/RS485 CUSTOMER BENEFITS High flexibility due to scalalbe pressure range Digital (RS485) and analogue (4-20mA) output signal in one sensor Available

More information

Pressure Measurement Transmitters for applications with advanced requirements (Advanced)

Pressure Measurement Transmitters for applications with advanced requirements (Advanced) Siemens AG 206 Technical specifications SITRANS P DS III series for absolute pressure (from the gauge pressure series) Input Measured variable Absolute pressure Span (fully adjustable) or measuring range,

More information

Dimensions. Technical Data General specifications Switching element function Rated operating distance s n 5 mm

Dimensions. Technical Data General specifications Switching element function Rated operating distance s n 5 mm Dimensions M18x1 37 40 4 0102 24 LED Model Number Features 5 mm embeddable Usable up to SIL2 acc. to IEC 61508 Connection BN BU Accessories L+ L- EXG-18 Quick mounting bracket with dead stop BF 18 Mounting

More information

ATM/Ex - Intrinsically Safe Analog Pressure Transmitter - ATEX / IECEx Certified

ATM/Ex - Intrinsically Safe Analog Pressure Transmitter - ATEX / IECEx Certified Intrinsically safe pressure transmitters ATM/Ex - Intrinsically Safe Analog Pressure Transmitter - ATEX / IECEx Certified CUSTOMER BENEFITS Certificate: ATEX & IECEx Fast customization thanks to configurable

More information

Features. Description

Features. Description Features Fast response flow meter ideal for inert gas and liquid mass flow measurement applications Smart electronics permit field adjustment of critical flow meter settings Field validation of flow meter

More information

ATM.ECO - Analog Pressure Transmitter

ATM.ECO - Analog Pressure Transmitter Pressure Transmitter ATM.ECO - Analog Pressure Transmitter CUSTOMER BENEFITS Entry level series into precision pressure measurement High measurement accuracy is ensured by sophisticated digital temperature

More information

ATM/Ex - Analog Pressure Transmitter

ATM/Ex - Analog Pressure Transmitter Pressure Transmitter - ATEX certified ATM/Ex - Analog Pressure Transmitter CUSTOMER BENEFITS Certificate: ATEX & EAC Fast customization thanks to configurable product design Demountable electrical connector

More information

Monitoring device NTS 30

Monitoring device NTS 30 P R O D U C T I N F O R M A T I O N Electronic level- and temperature monitoring device Monitoring device NTS 30 Contents Description Description... 2 Operating... 3 Design and electrical data... 4 Circuit

More information

INDUSTRIAL. Pressure Transmitters. Product Guide. Low cost to high accuracy portfolio. Ranges from 70 mbar to 1400 bar. Flexible, rugged and reliable

INDUSTRIAL. Pressure Transmitters. Product Guide. Low cost to high accuracy portfolio. Ranges from 70 mbar to 1400 bar. Flexible, rugged and reliable INDUSTRIAL Pressure Transmitters Product Guide Low cost to high accuracy portfolio Ranges from 70 mbar to 1400 bar Flexible, rugged and reliable Fixed and rangeable 4-20mA outputs Electrical/pressure connection

More information

How to specify a product. Process Sensors and Mechanical Instruments

How to specify a product. Process Sensors and Mechanical Instruments How to specify a product Process Sensors and Mechanical Instruments Keep the overview. Here is some guideline information on how to specify our products. Intended as supplementary help to specification

More information

Technical Data. General specifications Switching element function Rated operating distance s n 1.5 mm

Technical Data. General specifications Switching element function Rated operating distance s n 1.5 mm 0102 Model Number Features 1.5 mm flush Accessories BF 8 Mounting flange, 8 mm Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 1.5 mm Installation flush

More information

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI US Edition

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI US Edition Siemens AG 07 SITRANS LH00 Transmitter for hydrostatic level Overview Function U const. p U I EM The pressure transmitter SITRANS LH00 is a submersible sensor for hydrostatic level measurement. The pressure

More information

Pressure Switches Application Guideline

Pressure Switches Application Guideline Pressure Switches Application Guideline Product Overview The Fema Pressure Switch product portfolio provides devices suitable for many applications. The portfolio contains Special functions and equipment

More information

SITRANS P measuring instruments for pressure

SITRANS P measuring instruments for pressure Remote seals for transmitters and pressure gauges Technical description Overview In many cases the pressure transmitter and the measured medium have to be physically separated. It is then necessary to

More information

Two-Wire In Situ Oxygen Analyzer (550 to 1400 C)

Two-Wire In Situ Oxygen Analyzer (550 to 1400 C) Product Data Sheet PDS 106-581.A01 March, 2004 Model 5081FG Two-Wire In Situ Oxygen Analyzer (550 to 1400 C) Intrinsically safe: - CENELEC EEx ia IIC - Class I Div. I Gr. B, C, D (pending) Operates at

More information

High-performance submersible pressure transmitter For level measurement Model LH-10

High-performance submersible pressure transmitter For level measurement Model LH-10 Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-10 WIKA data sheet PE 81.09 Applications Level measurement in rivers and lakes Deep well

More information

ATM - Analog Pressure Transmitter

ATM - Analog Pressure Transmitter Pressure Transmitter ATM - Analog Pressure Transmitter CUSTOMER BENEFITS Fast customization thanks to configurable product design Demountable electrical connector option to allow adjustment of zero and

More information

Liquid level switch BM 34

Liquid level switch BM 34 KROHNE 09/2001 7.02370.21.00 GR/PRINTO Liquid level switch Status: 10/99 Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass flowmeters Level

More information

780S Ultra High Purity Series

780S Ultra High Purity Series Smart Ultra High Purity Thermal Gas Mass Flow Meter Features Measures mass flow directly, no seperate temperature or pressure inputs required Field adjustment of critical flow meter settings via on-board

More information

Hidrostatic Level DATASHEET

Hidrostatic Level DATASHEET Hidrostatic Level DATASHEET JUNHO 2013 Hydrostatic level probes SGE-25 and SGE-16 SG cable hanger Red (+) Capillary Black ( ) PP junction box Any measurement range from 1 up to 500 m H 2 O Integrated internal

More information

The M-Series Eletta Flow Meter High accuracy DP Flow Meter with multiple functions

The M-Series Eletta Flow Meter High accuracy DP Flow Meter with multiple functions The M-Series Eletta Flow Meter High accuracy DP Flow Meter with multiple functions Flow Meter with multiple functions for gases and liquids M3 The M-series Flow Meter, with its versatile and user-friendly

More information

OSAT Series. Intrinsically Safe Infrared Temperature Sensor Operator's Guide

OSAT Series. Intrinsically Safe Infrared Temperature Sensor Operator's Guide OSAT Series Intrinsically Safe Infrared Temperature Sensor Operator's Guide Issue L Jan 2017 Introduction OSAT Series intrinsically safe non-contact infrared temperature sensors measure the temperature

More information

7000 Series OPTIMASS Mass Flowmeters. Titanium Hastelloy Stainless Steel

7000 Series OPTIMASS Mass Flowmeters. Titanium Hastelloy Stainless Steel KROHNE 04/2003 7.02445.71.00 GR 7000 Series OPTIMASS Mass Flowmeters with single straight measuring tube Titanium Hastelloy Stainless Steel One tube no limits No limits with tube material No limits with

More information

Expert Hydrostatic Level Transmitters

Expert Hydrostatic Level Transmitters Expert Hydrostatic s General Features MJK Expert hydrostatic level transmitters are designed for level measurement by submerging the transmitter in open channels, drains and tanks. Expert hydrostatic level

More information

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm 00 Model Number Features 5 mm flush Usable up to SIL acc. to IEC 6508 Accessories V-G Female connector, M, -pin, field attachable V-W Female connector, M, -pin, field attachable V-G-N-M-PUR Female cordset,

More information

Tapped exhaust port. Sturdy, simple, reliable design. Easy to add on Feedback. High gain pilot valve. Simple calibration, external zero adjustment

Tapped exhaust port. Sturdy, simple, reliable design. Easy to add on Feedback. High gain pilot valve. Simple calibration, external zero adjustment Electropneumatic Positioner Sturdy, simple, reliable design High gain pilot valve Built in gauge ports Tapped exhaust port Easy to add on Feedback Unit F5 Simple calibration, external zero adjustment Bright

More information

ATM.1ST. Pressure transmitters CUSTOMER BENEFITS

ATM.1ST. Pressure transmitters CUSTOMER BENEFITS Pressure transmitters ATM.1ST CUSTOMER BENEFITS High precision pressure sensor over the whole temperature range Electronic compensation Modular sensor structure (any process and electrical connections

More information