Polatrak ROV II - Tip Contact Probe Operation Manual
|
|
- Kenneth Cox
- 6 years ago
- Views:
Transcription
1 This PDF document contains Live Web Links Click them for more information from the web Polatrak ROV II - Tip Contact Probe Operation Manual A Cathodic Protection Probe with dual Ag/AgCl reference cells for unparalleled accuracy. It can be diver held or mounted to an ROV friendly T-Handle (shown here). pg 1 of 15
2 Table of Contents 1 Dive-Spread Installation 3 2 ROV Instalaltion 3 3 Cautionary Notes 4 4 Calibration General Topside Calibrations (Bucket Cal.) Subsea Calibrations 5 5 Operation Wet Check Offshore Probe Maintenance Recording CP Potentials 7 6 Drawings and Calibration Forms ROV II Probe General Assembly ROV II Probe Detailed Assembly CP Survey Wiring w/ POLASCAN 12 panel (optional) 6.4 CP Surevy Wiring w/ Voltmeter Calibration Form (cell to cell) Calibration Form (vs Zn coupon) Calibration Form (vs. Master Ag/AgCl) 16 pg 2 of 15
3 Section 1 Installation for a Dive-Spread When used in conjunction with diving operations, it is recommended that a cable is assembled with a SEACON RMG-3MP connector at the subsea end. The most suitable cable in our experience is the 4 conductor armored spiral comms cable that is used by most divers for diver communications. This has two twisted pairs and is very rugged. A connection whip with this connector os provided with the probe and should be soft spliced onto the end of the comms cable. Ensure that the connection is taped back to the armored wire to provide strain relief on the connection. (If required, Deepwater Corrosion can provide a complete assembly on a 500 foot long umbilical cable.) The appropriate length of wire should be married into the dive hose leaving 4-6 feet of slack at the diver end and at least 50 feet at the topside end. Always install the dummy plug on the connector when the probe is not attached. The topside end of the wire will be run to the dive control area along with the platform ground cable and any ground from pipeline risers. The connections can be made either to a pair of digital multi-meters or to Polatrak Monitoring Panel available from Deepwater Corrosion Services. (Wiring hook-ups are shown in section 6 for the POLASCAN panel.) Section 2 ROV Installation The probe is best installed in or on a manipulator but may be attached directly to the ROV frame if there is no manipulator available (this is best when only proximity readings are required). The recessed grooves in the probe body may be used to accommodate stainless steel hose clamps for attachment, it is recommended that a safely line is provided as well as some neoprene rubber pads between the probe and the mounting surfaces, this will provide a better attachment and some degree of compliance. The connector on the back of the probe is a SEACON RMG-3FS and is wired as shown in Fig. 1 below. PIN 1 CONTACT TIP PIN 2 ELECTRODE #1 (R1) Fig. 1 PIN 3 ELECTRODE #2 (R2) pg 3 of 15
4 A male connector on a 6 0 whip is provided to facilitate splicing into the ROV junction box. It is recommended that the two electrode wires are routed in a shielded twisted pair in the ROV umbilical, the tip wire can be connected to a coaxial cable or any other cable that is straight through to the control van with no breaks. Topside the system can be wired directly into a video annotator (insure that it has an input impedance of at least 10 Meg Ohm / Volt), or onto either a pair of multi-meters or a Deepwater monitoring panel. See attached wiring schematics for hookup options. Section 3 Cautionary Notes Polatrak sintered silver chloride reference electrode elements are designed to withstand normal oilfield operations, but they are consumables that have a given operational life, the life of these electrodes can be extended to several seasons if the following care is taken. Never allow the electrode elements to be directly shorted to ground or any other metallic object when immersed in seawater. Never run the electrode subsea with the underwater connector un-mated. Never read the CP probe with an analog voltmeter, ensure that high input impedance digital equipment is used. Never handle the bare reference electrode element (small gray pellet) with bare or greasy hands. Do not use any type of solvent or detergent on the probe, rinse only in fresh water when not in use. Never immerse the electrode in anything but fresh water or sea-water. Never allow an underwater connector to be immersed unless it is mated or has a sealing dummy plug inserted. Never read the electrode on a multi-meter scale other than DC Volts. When not in use, store the probe in the container provided filled with seawater or tap water. Probe can be stored dry between jobs but should be rinsed in freshwater thoroughly before storage. Do not attempt to field repair any wires on the probe or inside the probe and never attempt to modify the probe tip in any way. pg 4 of 15
5 Section 4 Calibration 4.1 General It is imperative to follow calibration procedures precisely and to change electrodes if a probe shows to be out of calibration. Improperly reported CP readings could cause serious problems to the facility operator and may have to be repeated. The most common cause of problems, particularly on diver surveys, is damage to the cable insulation, this causes an offset in the reading which would usually be interpreted as inadequate protection levels, for this reason both topside and subsea calibrations should be performed before, during, and after every dive. Note: Oil company calibration specifications must be met, but we strongly advise also using the attached procedures. 4.2 Topside Calibrations (Bucket Calibration) If probes have been stored for a significant period, and have been allowed to dry out, it may take 1-2 hours of immersion time before the electrodes stabilize. The attached sheet shows the procedure; ensure that either native seawater or artificial seawater (3% by weight salt) is used. Procedures (forms are included for Cell to Cell, Master Silver/Silver Chloride, and zinc coupon checks). The zinc calibration coupon is provided as standard, but the master silver/silver chloride procedure is recommended). NEVER USE A METALLIC CONTAINER WHEN PERFORMING CALIBRATIONS OR FOR STORAGE. 4.3 Subsea Calibrations The subsea calibration procedures should be followed and the results logged at least once per dive Cell To Cell Calibrations This procedure checks one cell in the probe against the other, and should be performed with all the cable immersed as it will quickly detect any cable damage. If dual readouts are used as shown in the wiring diagrams, the cell to cell reading is displayed continuously, this is the recommended procedure. The cells should read within +/- 5 mv DC. If the value drifts outside this range then one of the following has happened: pg 5 of 15
6 1. Lead wire is damaged exposing copper to seawater. 2. A connector is not properly made or is leaking. 3. One cell has failed. If in the middle of a dive it is possible to complete the dive, however the defective cell should be isolated and the good cell used to finish the dive. The bad cell will normally be the one, which displays the most positive potential. So read a potential on the structure with both elements, the most negative cell should be used to complete the dive, and the offset noted. When recovering the umbilical cable from such a dive, monitor the cell-to-cell value, if the problem is lead wire damage, the value will revert to within +/- 5mV as soon as the damaged area clears the water, in this way the damage can be quickly located and repaired Ground Check This procedure verifies that the platform ground wire and the probe tip will yield the same reading at any point on the main structure. This is particularly important when the probe is being used in proximity mode. The POLASCAN READOUT has a facility to switch between tip and platform ground. To verify the ground, stab the steel structure under survey with the probe and record the value switching grounds from tip to platform, the reading should be identical, if it varies by more than +/ 3 mvdc, check the platform ground connection. Section 5 Operation Most oil companies will have their own survey procedures that should be followed. The following guidelines are given as guidance only. Connect the system as shown on the attached wiring schematics. 5.1 Wet Check When interfaced to an ROV, it important to perform a wet check before every dive. Signal errors caused by umbilical power cable interference could introduce reading errors. With the probe wire to the ROV, immerse the system to at least (-) 30 feet, and with the vehicle still in it s TMS bring up one electrical system at a time and note the potential of the tip (it will vary some depending on immersion time). If there is a problem, the potential will change rapidly or will spike when the circuit is powered. Repeat for all electrical and hydraulic systems. If a problem is detected it should be fixed, usually it s a poor ground connection or a faulty leaking underwater connector that cause the problem. If the system at fault can be switched off without hindering operation, this is an acceptable option. pg 6 of 15
7 5.2 Offshore Probe Maintenance Changing Electrodes - Spare plug-in electrode elements can be provided with the ROV II probe, these elements will also work in the CP Gun. If the elements or one element needs to be changed, follow this procedure: 1. Take the probe into a clean inside working area, with a clean grease free work surface. 2. Locate the assembly drawing at the back of this manual. 3. Remove the head assembly carefully by removing two screws on back of probe, pull out gently until two electrode connectors are visible. 4. Using an ohm meter measure between the connector pin and the electrode element to verify which is which. (Do not handle electrode elements). 5. Unplug the bad electrode(s) from connector(s), and discard. 6. Apply a small smear of silicone grease into the open female connector and insert the new electrode. (Avoid using excess grease, and any grease contact with electrode element.) 7. Check the integrity of the tip wire connector, re-make as necessary. 8. Carefully re-insert the electrodes into the probe body and replace the head assembly. 5.3 Recording CP Potentials If wired correctly the CP potentials should have a negative polarity. Accurate readings will be steady and not drifting so long as the probe is not moving. If readings are erratic this is a sign of a connection problem, and the cause should be isolated and fixed. To obtain accurate readings the probe apertures should be within 2 of the structure surface. The further away the probe is held from the structure area under investigation, the less accurate will be the reading. On offshore structures protected with zinc or aluminum anodes the following potential ranges should be observed. (-) (-) Volts On Jacket Members / Pipelines (-) (-) Volts On Anodes Readings outside of these ranges should be double-checked. It is possible to see potentials less negative than (-) Volts, but this would mean an unprotected structure with large numbers of consumed anodes or a high ratio of low potential anodes. pg 7 of 15
8 Section 6 Drawings and Calibration Forms The following drawings and forms are attached for reference: 1. Polatrak ROV II Dive Probe GA Page Polatrak ROV II Dive Probe Assembly Page CP Survey Wiring with Optional POLASCAN Monitoring Panel Page CP Survey Wiring Schematic with Twin Voltmeter Setup Page Calibration Form Cell to Cell Page Calibration Form vs. Zinc Coupon Page 14 \ 7. Calibration Form vs. Master Ag/AgCl Electrode Page 15 pg 8 of 15
9 pg 9 of 15
10 pg 10 of 15
11 pg 11 of 15
12 pg 12 of 15
13 pg 13 of 15
14 pg 14 of 15
15 pg 15 of 15
CP-Gun Diver-held probe Operation manual
Corrosion testing probes CP-Gun Diver-held probe Operation manual Twin reference electrodes verify calibration during use Ultra-bright LED displays for limited visibility conditions On-off switch for season-long
More informationMODEL ANALOG ALTIMETER USER'S MANUAL 330KHZ, 1000M DEPTH RATED 0.2 TO 100FT OPERATING RANGE ANALOG OUTPUT
MODEL 862-000-200 ANALOG ALTIMETER USER'S MANUAL 330KHZ, 1000M DEPTH RATED 0.2 TO 100FT OPERATING RANGE ANALOG OUTPUT DOCUMENT NO. 430-007H September 20, 2005 S/N IMAGENEX TECHNOLOGY CORP. 209-1875 BROADWAY
More informationMODEL DIGITAL ALTIMETER USER'S MANUAL 330KHZ, 1000M DEPTH RATED 0.5 TO 100FT (0.15 TO 30M) OPERATING RANGE SERIAL OUTPUT
MODEL 863-000-200 DIGITAL ALTIMETER USER'S MANUAL 330KHZ, 1000M DEPTH RATED 0.5 TO 100FT (0.15 TO 30M) OPERATING RANGE SERIAL OUTPUT DOCUMENT NO. 430-017C April 14, 2005 S/N IMAGENEX TECHNOLOGY CORP. 209-1875
More informationGASGUARD VENT LINE3 Ammonia Sensor OPERATING & INSTALLATION MANUAL
GASGUARD VENT LINE3 Ammonia Sensor OPERATING & INSTALLATION MANUAL Operating and Installation Manual Warning Use this product only in the manner described in this manual. If the equipment is used in a
More informationINSTRUCTION MANUAL. 840 Transmitter. Loop Powered Dissolved Oxygen Transmitter
INSTRUCTION MANUAL Loop Powered Dissolved Oxygen Transmitter Contents Contents...2 Introduction...3 Range and Display Settings...4 Installation...5 Electrical Installation...6 Calibration...7 EasyCal...8
More informationSaab Seaeye Cougar XT Compact
The Seaeye Cougar-XT Compact is a highly flexible and extremely powerful electric ROV with working depths of 300 metres. This system comes with almost all of the specifications of the very reliable Couger-XT
More informationUnderwater Wet Welding Products Operating Instructions
BROCO Inc. 400 S. Rockefeller Ave. Ontario, CA 91761 USA (909) 483-3222 (909) 483-3233 Fax (800) 845-7259 Underwater Wet Welding Products Operating Instructions Product Warnings WARNING Please read and
More informationWarner Instruments, Inc Dixwell Avenue, Hamden, CT (800) / (203) (203) fax
DH-40i, Rev. 04.03.02 Micro-Incubation Platform For RC-40 Chambers Model DH-40i 1125 Dixwell Avenue, Hamden, CT 06514 (800) 599-4203 / (203) 776-0664 (203) 776-1278 - fax DH-40i, Rev. 04.03.02 Table of
More informationHandling instructions for GISMA connectors HI
Content 1. GENERAL... 3 2. SCOPE... 3 3. PROTECTION, HANDLING AND SHIPMENT... 3 4. UNPACKING... 4 5. STORAGE... 4 5.1. Short Term Connector Storage... 4 5.2. Long Term Connector Storage... 4 6. Jumper
More informationUser Manual for Amron International Diving Supply, Inc.
User Manual for Amron International Diving Supply, Inc. Model 2810E and 2810E-1 One Diver Communicator S/N This manual and the information contained herein are provided for use as an operation and maintenance
More informationBante820 Portable Dissolved Oxygen Meter Instruction Manual
Bante820 Portable Dissolved Oxygen Meter Instruction Manual BANTE INSTRUMENTS CO., LTD Bante820 Portable Dissolved Oxygen Meter 1 Introduction Thank you for selecting the Bante820 portable dissolved oxygen
More informationTeledyne Oil & Gas North Williamson Blvd. Daytona Beach, FL USA (phone) (fax)
PER CO # 33537 Approved By: M. Bartell Originator: Checked By: S. Jackson B. Cornelius 1 of 8 ODN-084-23 23 TITLE: Installation and Operation Manual for Dry- Teledyne Oil & Gas 1026 North Williamson Blvd.
More informationGG-VL2-NH3 AMMONIA VENT LINE SENSOR. Installation and Operation Manual
GG-VL2-NH3 AMMONIA VENT LINE SENSOR Installation and Operation Manual 2 GG-VL2-NH3 Warning Use this product only in the manner described in this manual. If the equipment is used in a manner not specified
More informationBante810 Benchtop Dissolved Oxygen Meter Instruction Manual
Bante810 Benchtop Dissolved Oxygen Meter Instruction Manual BANTE INSTRUMENTS CO., LTD Bante810 Benchtop Dissolved Oxygen Meter 1 Introduction Thank you for selecting the Bante810 benchtop dissolved oxygen
More informationOPERATOR S MANUAL Ar-Gone Weld Gas Analyzer
July 2011 OPERATOR S MANUAL Ar-Gone Weld Gas Analyzer WARNING! Before operating this product, read and understand this Operator s Manual. Become familiar with the potential hazards of this unit. Contact
More informationPURA. Pure Gas Dewpoint Transmitter. Users Guide
PURA Pure Gas Dewpoint Transmitter Users Guide Issue January 2003 Page 2 Table of Contents SECTION PAGE 1 Product Overview 3 2 Preparation 3 3 Installation 3 3.1 PURA Premium & OEM Dewpoint Transmitter
More informationHI 2314 HI 2315 HI 23151
Instruction Manual HI 2314 HI 2315 HI 23151 Multi-Range Conductivity Meters for Laboratories www.hannainst.com Dear Customer, Thank you for choosing a Hanna Instruments product. Please read this instruction
More informationFTS SUBMERSIBLE PRESSURE TRANSMITTER USER S MANUAL
FTS SUBMERSIBLE PRESSURE TRANSMITTER USER S MANUAL TABLE OF CONTENTS PRODUCT OVERVIEW 2 I - USE AND CARE: 3 II - INSTALLATION: 5 III - GENERAL MAINTENANCE TIPS: 5 IV - APPENDIX: A-1 2-WIRE CURRENT LOOP
More informationQuality Assurance Procedure CP - 3
Quality Assurance Procedure Cathodic Protection System Testing Anode Output Measurements Using Swain AutoMer Meter CP - 3 Updated 3/16/2006 Written and Prepared by : Thomas M. Dennison This document is
More informationINSTRUCTION MANUAL. January 23, 2003, Revision 0
INSTRUCTION MANUAL Model 810A In-Vitro Test Apparatus for 310B Muscle Lever January 23, 2003, Revision 0 Copyright 2003 Aurora Scientific Inc. Aurora Scientific Inc. 360 Industrial Parkway S., Unit 4 Aurora,
More informationINSTALLATION PROCEDURE 1/4 & 1/8 MILE PERMANENT TRACK
INSTALLATION PROCEDURE 1/4 & 1/8 MILE PERMANENT TRACK 1) Unpack all of the equipment and immediately inspect for shipping damage. Damages should be immediately reported to the carrier and noted on the
More informationCCSSL35 Carry out the wiring and testing of electrical circuits and equipment
Carry out the wiring and testing of electrical circuits and equipment Overview This standard is about the basic competences that you need to wire up and test electrical equipment and circuits for the theatre
More informationDOscan10 Pocket Dissolved Oxygen Tester Instruction Manual
DOscan10 Pocket Dissolved Oxygen Tester Instruction Manual BANTE INSTRUMENTS CO., LTD DOscan10 Pocket Dissolved Oxygen Tester 1 Thank you for selecting the DOscan10 pocket dissolved oxygen tester. This
More informationPROPORTIONING VALVE. Model 150 INSTRUCTION MANUAL. March 2017 IMS Company Stafford Road
PROPORTIONING VALVE Model 150 INSTRUCTION MANUAL March 2017 IMS Company 10373 Stafford Road Telephone: (440) 543-1615 Fax: (440) 543-1069 Email: sales@imscompany.com 1 Introduction IMS Company reserves
More informationKube Engineering Quinn E. Eddins, B.S.E.E Phone
Process Information: There are four ph assemblies used to monitor the ph value on a Sulfur Dioxide absorber. The chemical composition is approximately 20-30% Sodium Bisulfite, 4% Sodium Sulfite, and the
More informationOC Panel High Limit Aquastat Kit, Manual Reset p/n
OC Panel High Limit Aquastat Kit, Manual Reset p/n 233202 Instruction Sheet APPLICATION The OC (Option Control) Panel High Limit Aquastat Kit provides electronic temperature sensing in a UL limit-rated
More informationDEEPSEA. LED Micro SeaCam POWER & LIGHT. Operator s Manual. Original Instruction Ruffin Road San Diego, CA USA
DEEPSEA POWER & LIGHT LED Micro SeaCam T: 858-576-1261 F: 858-576-0219 4033 Ruffin Road San Diego, CA 92123-1817 USA www.deepsea.com sales@deepsea.com Original Instruction REV 02/26/18 LED Micro SeaCam
More informationAPPLICATIONS ROV & AUV SEISMIC PRODUCTION SYSTEMS DOWNHOLE JUMPER & CABLE SYSTEMS DRILLING CONTROL
APPLICATIONS ROV & AUV SEISMIC PRODUCTION SYSTEMS DOWNHOLE JUMPER & CABLE SYSTEMS DRILLING CONTROL ROV & AUV PRODUCTS GRE (Glass Reinforced Epoxy) CS-MS 55 & 66 SERIES MINI-CON HUMMER GLOBE-CON ALL-WET
More information32374 R. Jazowski 4/4/ D. W. Mudge G. Sivik 1 of 8 ODN TITLE: Installation & Operation Manual for Nautilus G2 Connectors
PER CO # Approved By: 32374 R. Jazowski Originator: Checked By: W. Mudge G. Sivik 1 of 8 ODN-342-23 23 TITLE: Installation & Operation Manual for Nautilus Teledyne Oil & Gas 1026 North Williamson Blvd.
More informationBI-680 Online Dissolved Oxygen Controller Instruction Manual
BI-680 Online Dissolved Oxygen Controller Instruction Manual BANTE INSTRUMENTS CO., LTD BI-680 Online Dissolved Oxygen Controller 1 Introduction Thank you for selecting the BI-680 online dissolved oxygen
More informationNewsletter of Jointing, Welding & Cold-Formed Steel Group, HKISC UNDERWATER WELDING. Ir Dr Chan Wai Tai. Chairman of Welding Group, HKISC
UNDERWATER WELDING Ir Dr Chan Wai Tai Chairman of Welding Group, HKISC When I was young, I was always fascinated by welding carried out in underwater environment. Basically, flame and water are mutual
More informationInstruction Manual HI Portable Waterproof Dissolved Oxygen Meter.
Instruction Manual HI 9142 Portable Waterproof Dissolved Oxygen Meter www.hannainst.com 1 Dear Customer, Thank you for choosing a Hanna Instruments Product. Please read this instruction manual carefully
More informationUser Manual V14.1 IP68 LED FLEX NEON
User Manual V14.1 IP68 LED FLEX NEON PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLATION LEAVE A COPY FOR THE END USER/MAINTENANCE ENGINEER FOR FUTURE REFERENCE 1/11 PRODUCT SPECIFICATION 1. Operating
More informationMODEL GT820 OXYGEN SENSOR
INSTRUCTION MANUAL MODEL GT820 OXYGEN SENSOR 70046 The information and technical data disclosed by this document may be used and disseminated only for the purposes and to the extent specifically authorized
More informationAllspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW. Tel +44 (0)
Allspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW Tel +44 (0)1254 615100 www.allspeeds.co.uk SOFT LINE CUTTER SL55 PRODUCT CODE No. 980504 INSTRUCTIONS FOR INSTALLATION,
More informationCovered Task 409OP Training Guide Inspecting Interference Bonds
Directions This training guide is to be used by a Subject matter expert (SME) authorized Evaluator/Trainer and Trainee during on-thejob training (OJT) or prior to an evaluation as a resource. (S) Indicates
More informationInstallation, Operation, and Maintenance Manual. Welker Constant Pressure Cylinder With Solid Indicator (Non-mixer) Model CP-30SI
Installation, Operation, and Maintenance Manual Welker Constant Pressure Cylinder With Solid Indicator (Non-mixer) Model The information in this manual has been carefully checked for accuracy and is intended
More informationOEM Manual MODEL 2305 ECONOMICAL DIGITAL SINGLE CYLINDER SCALE
OEM Manual MODEL 2305 ECONOMICAL DIGITAL SINGLE CYLINDER SCALE 1 These instructions generally describe the installation, operation, and maintenance of subject equipment. The manufacturer reserves the right
More informationSG36KTL-M Quick Installation Guide. 1 Unpacking and Inspection
SG36KTL-M Quick Installation Guide This guide provides a general instruction of the installation procedures of SG36KTL-M. In no case shall this guide substitute for the user manual or related notes on
More informationGILMONT ACCUCAL FLOWMETERS
OPERATING MANUAL GILMONT ACCUCAL FLOWMETERS 28W092 Commercial Ave. Barrington, IL U.S.A. 60010-2392 (847) 381-4888 (847) 381-7053 (Fax) 800-962-7142 www.barnant.com e-mail: barnant@barnant.com A-1299-0766
More informationShimano Di2 Installation on S5
Installing Shimano Dura Ace Di2 Shifting Systems Note these instructions and pictures are for assembling the Shimano Dura Ace Di2 system (Internal Spec) on the Cervélo S5 frame. The Shimano Ultegra Di2
More informationCathodic Protection and Underwater Survey for an Floating Storage Offloading (FSO) System
Cathodic Protection and Underwater Survey for an Floating Storage Offloading (FSO) System Michael Surkein*, Omarou Faricou & Joseph Kenmoe ExxonMobil *Mike is currently retired from ExxonMobil and Principal
More informationOxyCheq Expedition-X Oxygen Analyzer. Operator s Manual
OxyCheq Expedition-X Oxygen Analyzer Operator s Manual OxyCheq 3528 Russell Road Marianna, Florida 32446 USA Tel: 850.482.0385 Email: oxy@oxycheq.com Web: http://oxycheq.com CONTENTS 1.0 Introduction..
More informationWelding With Arc Welding Equipment
Optional Information Name of School: Date of Inspection: Vocational Program/Course/Room: Signature of Inspector: Welding With Arc Welding Equipment Self Inspection Checklist Guidelines: This checklist
More informationSTERILIZABLE DISSOLVED OXYGEN SENSORS
STERILIZABLE DISSOLVED OXYGEN SENSORS USER MANUAL Table of Contents 1. Introduction 2. Operation 3. Calibration 4. Electrode Verification 5. Mounting 6. Maintenance 7. Storage 8. Instructions for Exchange
More information! Warning, refer to accompanying documents.
About this Manual To the best of our knowledge and at the time written, the information contained in this document is technically correct and the procedures accurate and adequate to operate this instrument
More information5 Channel Calibrator
212 N. Woodwork Lane Palatine, IL 60067 800-223-3977 5 Channel Calibrator Part # 0724 User Manual Questions? Contact us at 800-223-3977 or online at http://www.cleanair.com/equipment/express/main.html
More informationSTEAM STERILIZABLE POLAROGRAPHIC OXYGEN ELECTRODE
STEAM STERILIZABLE POLAROGRAPHIC OXYGEN ELECTRODE GENERAL INFORMATION This family of dissolved oxygen electrodes is of the steam sterilizable polarographic type, designed to be interchangeable with NBS
More informationStand-Alone Bubble Detection System
Instruction Sheet P/N Stand-Alone Bubble Detection System 1. Introduction The Bubble Detection system is designed to detect air-bubble induced gaps in a bead of material as it is being dispensed. When
More informationTechnical Data Sheet MF010-O-LC
Technical Data Sheet MF010-O-LC - 1 - 1. Properties The oxygen measuring system MF010-O-LC determines the oxygen content in gas mixtures up to a temperature of 250 C. It is particularly suitable for the
More informationSG33KTL-M Quick Installation Guide. 1 Unpacking and Inspection
SG33KTL-M Quick Installation Guide This guide provides a general instruction of the installation procedures of SG33KTL-M. In no case shall this guide substitute for the user manual or related notes on
More informationSimple, Robust, Reliable Measures ph Doses either acid (lower) or alkali (raise) Displays ph, Total Dose Count (DCT) and Dose Count per hour (DC/h)
Simple, Robust, Reliable Measures ph Doses either acid (lower) or alkali (raise) Displays ph, Total Dose Count (DCT) and Dose Count per hour (DC/h) Integrated peristaltic dosing pump When using automatic
More informationCygnus Underwater. UT Meters & Spare Parts Sales. Searchwise Aberdeen Ltd Unit 6, Broomiesburn, Ellon Ind Estate, Ellon, Aberdeenshire, UK, AB41 9RD
Cygnus Underwater UT Meters & Spare Parts Sales The Cygnus Underwater is the original diver held subsea multiple echo Ultrasonic Thickness Gauge. It was designed for use by divers undertaking subsea maintenance
More informationModel PDT Dewpoint Transmitter
Model PDT Dewpoint Transmitter Instruction Manual Alpha Moisture Systems Alpha House 96 City Road Bradford BD8 8ES England Tel: +44 1274 733100 Fax: +44 1274 733200 email: mail@amsytems.co.uk web: www.amsystems.co.uk
More informationUnderwater Housing for Canon EOS M
Underwater Housing for Canon EOS M User Manual 1 Table of Contents 1. Introduction 2. Specifications 3. Function Controls 4. Set up Instructions 5. Use & Care of Housing 6. Service 7. Warranty 1. Introduction
More informationCleaning rod: spring steel, stainless steel or carbon fibre cleaning rod - only use a one-piece rod. Avoid using snakes.
Telemark Biathlon Where performance and precision come together http://telemarkbiathlon.com Rifle Cleaning Date : July 19, 2013 Anschutz Rifle Manual - Click Here Izhmash 7-3 Rifle Manual - still looking
More informationDIY - PC - Interface for Suunto Cobra/Vyper/Mosquito
DIY - PC - Interface for Suunto Cobra/Vyper/Mosquito Summary This document is the distinct consequence of the Spyder/Stinger interface DIY. After having many e-mails concerning the application for the
More informationPRODUCT SPECIFICATION
MINI-FIT SR. SERIES 1.0 SCOPE This specification covers the 10.00 mm / (.394 in.) centerline tin and gold plated connector series, single and dual row versions in wire to wire and wire to printed circuit
More informationHandling instructions for GISMA connectors HI
Content 1. GENERAL... 3 2. SCOPE... 3 3. PROTECTION, HANDLING AND SHIPMENT... 3 4. UNPACKING... 4 5. STORAGE... 4 5.1. Short Term Connector Storage... 4 5.2. Long Term Connector Storage... 4 6. Jumper
More informationPRODUCT SHEET. Order probe only as RXPROBE02
SS69L DISSOLVED OXYGEN PROBE TRANSDUCER Order probe only as RXPROBE02 Order interface only as BSL-TCI16 SS69L Components The SS69L transducer measures dissolved oxygen. The SS69L includes a dissolved oxygen
More informationMini-Pro CO2 Sensor User s Manual - ANALOG MODEL -
Mini-Pro CO2 Sensor User s Manual - ANALOG MODEL - Table of Contents 1. Introduction 3 2. Instrument Setup 4 2.1 Instrument Checklist 4 2.2 Optional Accessories 4 2.3 Gas Concentration Ranges Available
More informationP9000 DESCRIPTION. For parts requiring RoHS compliance, please contact factory. P February /6
P9000 High accuracy through digital compensation High thermal stability Rugged stainless steel construction Ideal for test stands High burst pressure limit DESCRIPTION The P9000 Series is a range of advanced,
More informationCorrosion problems in seawater pump caissons. Practical solutions.
Corrosion problems in seawater pump caissons. Practical solutions. Svenn Magne Wigen FORCE Technology Norway AS Hornebergveien 7 7038 Trondheim, Norway Harald Osvoll FORCE Technology Norway AS Hornebergveien
More informationInstruction Manual Updated 7/26/2011 Ver. 2.2
4-Unit Model MB HTHP Filter Press #171-50-4: 115-Volt #171-51-4: 230-Volt Instruction Manual Updated 7/26/2011 Ver. 2.2 OFI Testing Equipment, Inc. 11302 Steeplecrest Dr. Houston, Texas 77065 U.S.A. Tele:
More informationDTG - LCD Digital Temperature Gauge USER MANUAL
DTG - LCD USER MANUAL Page 1 of 7 USERS GUIDE page 1. Description 3 2. Function 3 3. Safety Instruction 3 3.1. Safety Conventions 3 3.2. Proper Use 3 4. Installation 4 4.1. Unpacking 4 4.2. Storage 4 4.3.
More informationROV Development ROV Function. ROV Crew Navigation IRATECH SUB SYSTEMS 2010
IR AT EC H SU B SY ST EM S 20 10 Remotely Operated Vehicle ROV INTRODUCTORY 2008 2008 1 KEY POINTS ROV Introductory ROV Development ROV Function Types of ROV ROV Crew Navigation ROV Components 2 ROV Development
More informationLogIT Dissolved Oxygen Probe
LogIT Dissolved Oxygen Probe INTRODUCTION The LogIT Dissolved Oxygen Probe (DO2) has been designed especially for LogIT and is easy to set up and use. It features simple single control calibration and
More informationAMS 2710 PCB pressure sensor module with V output
FEATURES Universal pressure sensor module with 0.. 10 V voltage output Fully calibrated and temperature compensated sensor module Variants for (bidirectional) differential, gage, absolute and barometric
More informationINSTRUCTION MANUAL. Gas Salamander
INSTRUCTION MANUAL Gas Salamander This manual contains important information regarding your unit. Please read this manual thoroughly prior to equipment set-up, operation and maintenance. Failure to comply
More informationInstallation, Compensation and Maintenance Instructions for. RITCHIE Compasses. Made In U.S.A
Installation, Compensation and Maintenance Instructions for RITCHIE Compasses Made In U.S.A All Magnetic Compasses are vulnerable to magnetic interference, which will produce errors, called deviation.
More informationSunbrite LTC Large Underwater Pool Lights
Sunbrite LTC Large Underwater Pool Lights O W N E R S M A N U A L 3050 0997 ASB INSTALLATION, OPERATION & PARTS This manual should be furnished to the end user of this light; its use will reduce service
More informationPreferred Instruments Danbury, CT USA
Tank Level Sensor Model TG-EL-WF-xx Installation & Operation Instructions SDI-TG-EL-WF March 6, 2006 Preferred Instruments Danbury, CT USA www.preferredinstruments.com CONTENTS Installation Pg. 2 Calibration
More informationModel 106 DPI "Micro-switch" Installation and Operating Instructions
Mid-West Instrument Model 106 DPI "Micro-switch" Installation and Operating Instructions BULLETIN NO. IM116DPImicro/09A Replaces --- INSPECTION Before installation carefully check the Model Number on each
More informationSEMME2135 Assisting in modifying and adding electrical circuits in yachts and boats
Assisting in modifying and adding electrical circuits in yachts and boats Overview This standard identifies the competences you need to assist with the modification or addition of electrical circuits in
More informationInoxair. Repair Manual. Content. Edition: 12/2010. Subject to technical changes for reasons of the continous development.
Inoxair Repair Manual Edition: 12/2010 Content 1) Serial number 2) Technical data 3) Functional principle 4) Problem analysis 5) Removal 6) Repairs 7) Circuit diagram and cable-connection-plan 8) Pneumatic
More informationDesign Features. General Description
Model thermal Mass Flow Controllers are designed to indicate and control set flow rates of gases. The combines the characteristics and accuracy of conventional mass flow devices into a unique compact design
More informationEC214 EC215 - EC215R Bench Conductivity Meters
Instruction Manual EC214 EC215 - EC215R Bench Conductivity Meters http://www.hannainst.com These Instruments are in Compliance with the CE Directives Dear Customer, Thank you for choosing a Hanna Instruments
More informationRAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions
RAM 4021-PR Operation Manual Worldwide Manufacturer of Gas Detection Solutions TABLE OF CONTENTS RAM 4021-PR For Your Safety... 2 Description.... 2 Setup Mode.... 2 Lights/Alarms.... 3 Operation.... 4
More informationMembrane covered optical CO 2 sensor
Membrane covered optical CO 2 sensor - Manual - 30 mg/l CO 2, 4-20 ma output Exclusively Distributed & Supported By: www.edaphic.com.au info@edaphic.com.au Ph: 1300 430 928 Warning! Do never try to unscrew
More informationInstruction Manual HI Portable Dissolved Oxygen Meter. DO meter HI 8043 STB C OFF O 2 ZERO SLOPE C. ins rum n s
Instruction Manual HI 8043 Portable Dissolved Oxygen Meter DO meter HI 8043 ZERO SLOPE C ins rum n s This Instrument is in Compliance with the CE Directives Dear Customer, Thank you for choosing a Hanna
More informationModel PSI Compressor with 3-Gallon Air Tank 12VDC
Model 6350 150 PSI Compressor with 3-Gallon Air Tank 12VDC IMPORTANT: It is essential that you and any other operator of this product read and understandd the contents of this manual before installing
More informationVacuum grease can be applied to Warner chambers by use of a small artist s dotting brush or a syringe. Both approaches are described below.
Series 20 Chamber Instructions Model RC-21BRFS Closed Bath Imaging Chamber with Field Stimulation SERIES 20 CHAMBERS A feature in common with all Series 20 chambers is the use of a glass coverslip for
More informationSacrificial anodes for protection of seawater pump caissons against galvanic corrosion. Jan Heselmans Corrodium bv Planetenweg 5 NL-2132 HN Hoofddorp
Paper No. 11056 2011 Sacrificial anodes for protection of seawater pump caissons against galvanic corrosion Jan Heselmans Corrodium bv Planetenweg 5 NL-2132 HN Hoofddorp Nico (Ko) W. Buijs Innomet bv Rijksstraatweg
More informationAllspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW. Tel +44 (0)
Allspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW Tel +44 (0)1254 615100 www.allspeeds.co.uk SOFTLINE CUTTER SL80 PRODUCT CODE No. 980248 INSTRUCTIONS FOR INSTALLATION,
More informationInstallation, Operation, and Maintenance Manual
Installation, Operation, and Maintenance Manual Welker Constant Pressure Cylinder With Welker Magnetic Indicator (Non-mixer) Model The information in this manual has been carefully checked for accuracy
More informationT EK-SUB 4800C 19 mm Submersible Level Transmitter
Technology Solutions T EK-SUB 4800C 19 mm Submersible Level Transmitter Instruction Manual Document Number: IM-4800C www.tek-trol.com Table of Contents 1 Safety Instructions... 2 1.1 Intended Use... 2
More informationEASIDEW TRANSMITTER with Current Source Output
EASIDEW TRANSMITTER with Current Source Output INSTALLATION, OPERATION AND MAINTENANCE MANUAL Issue March 2002 2 TABLE OF CONTENTS SECTION PAGE 1. INTRODUCTION 3 1.1 General 3 1.2 Ceramic Sensing Element
More informationCRYOGENIC TANK SERVICES - CHART RECORDER MANUAL
CRYOGENIC TANK SERVICES - CHART RECORDER MANUAL Pressure Chart Recorder / Temperature Chart Recorder / Dual Recorder Portable Mechanical Chart Recorder for the accurate measurement and recording of Pressure
More informationjáåêçtbqj`lkpmifqseries
UNDERWATER ELECTRICAL WET-MATE CONNECTORS CONTENTS PAGE SECTION PAGE tbqj`lkpmifqseries Introduction... MWC 19 Availability... MWC 19 Applications... MWC 19 Testing... MWC 19 Special Assemblies... MWC
More informationModel DPC3500 Continuous Low Range Dew Point Analyzer. Operations Manual
Model DPC3500 Continuous Low Range Dew Point Analyzer Operations Manual Please read, understand, and follow these instructions before operating this equipment. Super Systems, Inc. is not responsible for
More informationRAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions
RAM 4021 Operation Manual Worldwide Manufacturer of Gas Detection Solutions TABLE OF CONTENTS RAM 4021 For Your Safety... 2 Description.... 2 Setup Mode.... 2 Lights/Alarms.... 3 Operation.... 4 Calibration....
More informationMulti-Probe Sampling System User Guide & Manual
Multi-Probe Sampling System User Guide & Manual Rev. 06/05/12 Part #22200012 Table of Contents CHAPTER 1: SYSTEM DESCRIPTION... 2 FUNCTION AND THEORY... 3 SYSTEM COMPONENTS... 4 CHAPTER 2: SYSTEM INSTALLATION...
More informationDigiTRON Electrical Flying Leads, Jumpers and Harness Assemblies Site Received Test Manual
1 Document No: SRT-001 DigiTRON Electrical Flying Leads, Jumpers and Harness Assemblies Site Received Test Manual www.siemens.com/energy/connector-operations-manual 2 This page records the revision status
More informationHST-3000 VDSL QUICK CARD
HST-3000 VDSL QUICK CARD ( ) March 2012 Technical Assistance: 1-866-228-3762 TAC@jdsu.com Resistive Fault Location (RFL) Test Purpose The purpose of this test is to identify and locate resistive fault
More informationRAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions
RAM 4021 Operation Manual Worldwide Manufacturer of Gas Detection Solutions TABLE OF CONTENTS RAM 4021 For Your Safety... 2 Description.... 2 Setup Mode.... 2 Lights/Alarms.... 3 Operation.... 4 Calibration....
More informationP499 Heavy Duty Pressure Transducer
P499 Heavy Duty Pressure Transducer Product Bulletin Code No. LIT-??? E Issued 11 2006 The P499 Series is a new global Pressure Transducer with an excellent price performance ratio. The P499 exceeds the
More informationGas Network Craftsperson
Gas Network Craftsperson Unit EIAU06 Maintaining Instrumentation and Control Equipment Circuits This assessment specification has been developed as part of the network maintenance craftsperson standard
More informationUnisense In Situ UniAmp Connector System
Unisense In Situ UniAmp Connector System Overview The Unisense In Situ UniAmp Connector system is designed for easy replacement of sensors. Unisense In Situ UniAmp Connector system is a dedicated system
More informationCCS240 and CCS241. Technical Information. Sensors for chlorine dioxide Amperometric, membrane-covered sensors for installation in the CCA250 assembly
Technical Information CCS240 and CCS241 Sensors for chlorine dioxide Amperometric, membrane-covered sensors for installation in the CCA250 assembly Application Chlorine dioxide is used for disinfection
More informationB. Assemble the Method-25 sample train with a heated probe/filter.
6/30/2015 VOC Reporting, Inc. Method 25 Heated Controller Operating Instructions. pg. 1 of 5 INSTRUCTIONS FOR EPA METHOD-25 FIELD SAMPLE COLLECTION USING A VRi HEATED PROBE AND FILTER ASSEMBLY Introduction:
More information