Advanced Neuromonitoring Solutions ICP. Oxygen Partial Pressure, Intracranial Pressure and Temperature Measurement. Drainage
|
|
- Ira Daniels
- 6 years ago
- Views:
Transcription
1 Advanced Neuromonitoring Solutions Oxygen Partial Pressure, Intracranial Pressure and Temperature Measurement Drainage O Temperature
2 Table of contents Page Microchip catheters with maximum precision NEUROVENT Microchip catheters 3 NEUROVENT microchip catheters are used for the reliable measurement of: and temperature measurement 4-5 Accessories for and temperature measurement 6-7 Oxygen partial pressure measurement 8-9 (intracranial pressure) ICT (intracranial temperature) p ti O 2 (oxygen partial pressure) Accessories for oxygen partial pressure measurement is measured using semiconductor pressure sensors. The quenching process of fluorescence is used to measure p ti O 2. Consequently the level and changes in the parameters are measured safely, quickly and accurately. RAUMEDIC offers a wide range of microchip catheters for parenchyma as well as ventricular measurement. NEUROVENT -PTO: Pressure (), Temperature, Oxygen Partial Pressure (p ti O 2 ) References: An outcome analysis of two different procedures of burr-hole trephine and external ventricular drainage in acute hydrocephalus. Schödel P, Proescholdt M, Ullrich OW, Brawanski A, Schebesch KM J Clin Neurosci Feb;19(2): Bench test assessment of the new Raumedic Neurvent-P sensor: a technical report by the BrainIT Group. Citerio G, Piper I, Cormio M, Galli D, Cazzaniga S, Enblad P, Nilsson P, Contant C, Chambers I; BrainIT Group. Acta Neurochir (Wien) Nov;146(11): Accuracy and stability of temperature probes for intracranial applications. Alessandri B, Hoelper BM, Behr R, Kempski O. J Neurosci Methods Oct 30;139(2): Clinical evaluation of a new intracranial pressure monitoring device. Stendel R, Heidenreich J, Schilling A, Akhavan-Sigari R, Kurth R, Picht T, Pietilä T, Suess O, Kern C, Meisel J, Brock M. Acta Neurochir (Wien) Mar;145(3):185-93; discussion 193. Evaluation of a novel brain tissue oxygenation probe in an experimental swine model. Orakcioglu B, Sakowitz OW, Neumann JO, Kentar MM, Unterberg A, Kiening KL. Neurosurgery Dec;67(6): ; discussion Brain tissue oxygen monitoring: a study of the in vitro accuracy and stability of the Neurovent-PTO and Licox sensors. Purins K, Enblad P, Sandhagen B, Lewén A. Acta Neurochir (Wien) Apr;152(4):
3 Temperature Intracranial pressure and temperature measurement NEUROVENT -P and NEUROVENT Drainage Intracranial pressure () and temperature measurement can be achieved safely, quickly and accurately using RAUMEDIC s innovative catheters with semiconducter sensors. Parenchyma monitoring of with NEUROVENT-P; with integrated temperature measurement using NEUROVENT-P-TEMP Ventricular monitoring of and CSF drainage with NEUROVENT; with integrated temperature measurement using NEUROVENT-TEMP Parenchyma monitoring of and ventricular drainage using NEUROVENT-Sleeve Housing Technical Data Catheters Diameter NEUROVENT-P NEUROVENT-P-TEMP + temperature Parenchyma Ventricular NEUROVENT + drainage, stylet NEUROVENT-IFD-S + drainage, inset guide wire soft NEUROVENT-IFD-R + drainage, inset guide wire rigid NEUROVENT-TEMP + drainage + temperature, stylet NEUROVENT-TEMP-IFD-S + drainage + temperature, inset guide wire soft NEUROVENT-TEMP-IFD-R + drainage + temperature, inset guide wire rigid NEUROVENT-Sleeve Housing in parenchyma + ventricular drainage Pressure measurement range -50 to mmhg (-6.7 to 33.3 Pa) Bandwidth > 100 Hz Measurement range temperature sensor +25 C to +45 C +77 F to +113 F Temperature accuracy in measurement range ±0.1 C Catheter material Polyurethane Pressure sensibility 5 µv/v/mmhg NEUROVENT-P NEUROVENT Zero Drift Pressure Less than 1 mmhg during the first 24 hours at 37 C (98.6 F) Less than 2 mmhg during the first week at 37 C (98.6 F) Average deviation 0.6 mmhg after 5 days* Clinical benefits: No additional monitor Plug & Play system no catheter calibration required Simultaneous measurement, CSF drainage and temperature measurement NEUROVENTSleeve Housing Connection directly to the patient monitor Compatible with all standard patient monitors Pressure measurement during transport Consistent reproducibility of pressure curves with high precision resolution for wave analysis Excellent stability and linearity of measuring values Zero Point Simulator allows for easy replacement of patient monitor without losing measured values 4 * Bench test assessment of the new Raumedic Neurovent-P sensor: a technical report by the BrainIT group Citerio G., Piper I., Cormio M., Galli D., Cazzaniga S., Enblad P., Nilsson P., Contant C., and Chambers I., BrainIT Group Acta Neurochirurgica (Wien). 2004, Aug; DOI: /s z 5
4 Components of the RAUMEDIC BOLT KIT 1. BOLT including seal and fixing cap 2. Dura opener 3. Screwing in tool BOLT and DRILL KIT Components of the RAUMEDIC DRILL KIT 4. DRILL bit with stopper 5. Allen key 1 Measuring chain from the catheter to the patient monitor Implantation Accessories BOLT KIT CH5 (parenchyma) DRILL KIT CH5 (parenchyma) BOLT KIT CH9 (ventricular) DRILL KIT CH9 (ventricular) Tunneling Sleeve CH8 (parenchyma) Tunneling Sleeve CH12 (ventricular) BOLT KIT Advantages: Low profile -TEMP-Cable Art.No.: Self-cutting conical thread with sealing function NPS2 Available for all standard monitor types Cables and Adapters -TEMP-Cable TEMP-Adapter TEMP-Adapter Philips/HP NPS2 Philips/HP NPS2 GE/MARQUETTE NPS2 Siemens/Dräger Infinity NPS2 Nihon Kohden BSM NPS2 Datex Ohmeda NPS2 SpaceLabs NPS2 Fukuda Denshi NPS2 Schiller NPS2 Hellige Patient monitor Alternative NPS3 NPS2 for additional monitor types upon request Mobile Pressure Measurement NPS
5 Oxygen partial pressure measurement NEUROVENT -PTO Measurement of oxygen partial pressure (ptio2) shows the available oxygen in the brain tissue and allows for early detection of cerebral damage to help prevent secondary injury. The quenching process of fluorescence is used to measure ptio2. Catheters Dimension NEUROVENT-PTO + temperature + ptio2 NEUROVENT-PTO 2L + temperature + ptio2 for use with BOLT KIT PTO 2L NEUROVENT-TO Temperature + ptio2 3F NEUROVENT-PTO; provides oxygen partial pressure, and temperature measurements in the parenchyma NEUROVENT-PTO 2L; provides oxygen partial pressure, and temperature measurements in the parenchy- NEUROVENT-PTO ma. Catheter designed specifically for BOLT KIT PTO 2L (two lumen BOLT); to be used with microdialysis Technical Data NEUROVENT-TO; provides oxygen partial pressure and temperature measurements in the parenchyma Pressure measurement range -50 to mmhg (-6.7 to 33.3 kpa) Bandwidth > 100 Hz Measurement range temperature sensor +25 C to +45 C +77 F to F Temperature accuracy in measurement range ± 0.1 C Catheter material Polyurethane Pressure sensibility 5 µv/v/mmhg Measurement process ptio2 Fiber optic ptio2 measuring surface 22 mm2 Measurement* range ptio mmhg One catheter; three measurement functions ICT ptio2 NEUROVENT-TO Catheter for measuring temperature and ptio2 Zero Drift Pressure Less than 1 mmhg during the first 24 hours at 37 C (98.6 F) Less than 2 mmhg during the first week at 37 C (98.6 F) Average deviation 0.6 mmhg after 5 days** Clinical advantages: Parenchyma pressure, temperature and ptio2 measurement in one catheter Plug & play system no catheter calibration required No oxygen consumption by the O2 sensor Large oxygen sensor window NEUROVENT-PTO 2L No refrigeration of catheter required Application with BOLT KIT PTO 2L and Tunneling Sleeve. Data acquisition using RAUMEDIC EASY logo Excellent long-term stability and linearity of measuring values Compatible with standard patient monitors 8 *Measurement accuracy ± 2.5 mmhg ptio2 (for < 120 mmhg ptio2) **Bench test assessment of the new Raumedic Neurovent-P sensor: a technical report by the BrainIT group Citerio G., Piper I., Cormio M., Galli D., Cazzaniga S., Enblad P., Nilsson P., Contant C., and Chambers I., BrainIT Group Acta Neurochirurgica (Wien). 2004, Aug; DOI: /s z 9
6 Implantation Accessories BOLT KIT PTO 2L BOLT KIT PTO BOLT with single lumen, only for NEUROVENT-PTO/-TO CH5 Dimension DRILL KIT CH5 Drill bit and allen key CH BOLT KIT PTO 2L BOLT with two lumens, only for NEUROVENT-PTO 2L CH DRILL KIT CH9 Drill bit and allen key CH Spliceable Tunneling Sleeve Parenchyma Tunneling Sleeve for NEUROVENT-PTO 2L CH BOLT with two lumens for safe and functional implantation of the NEUROVENT-PTO 2L and a microdialysis catheter Data Acquisition and Accessories EASY logo Acquisition of + ICT + ptio2 measurement values Cable LWL Fiber optic connecting cable for ptio2 to EASY logo Connecting cable for pressure and temperature to EASY logo Stand Holder Pole mounting device for EASY logo Table Stand Table mounting device for EASY logo Cable PTO EASY logo Connecting Cables (EASY logo to patient monitor) 10 Cable DATALOGGER GE/MARQUETTE Cable DATALOGGER Philips/HP Cable DATALOGGER Siemens/Dräger Infinitiv Cable DATALOGGER Datex Ohmeda Cable DATALOGGER Hellige Cable DATALOGGER SpaceLabs Cable DATALOGGER Nihon Kohden Acquisition of, ICT and ptio2 measurement values using a single device Simple and safe operating interface Light weight Analog output Compatible with standard patient monitors 11
7 Service Worldwide! RAUMEDIC Brain Competence RAUMEDIC, INC Edwards Ferry Road Leesburg, Virginia 20176, USA Commerce Street, Suite 108 Lake Mary, FL C96N009 US 02_2014 Copyright by RAUMEDIC AG Sources: Heading: AlienCat Fotolia.com rear page: Sebastian Kaulitzki Fotolia.com Toll Free: Tel: Fax:
Advanced Neuromonitoring Solutions ICP. Oxygen Partial Pressure, Intracranial Pressure and. Temperature. Drainage. Measurement O 2.
Advanced Neuromonitoring Solutions ICP Oxygen Partial Pressure, Intracranial Pressure and Temperature Measurement Drainage Temperature Table of contents Page Microchip catheters with maximum precision
More informationTSE Blood Pressure Monitor Invasive series
TSE Blood Pressure Monitor Invasive 209100series For Invasive Measurements in Laboratory Animals 2 Specifications subject to change without notice USA / Canada / Mexico Phone 1-989-698-3067 Fax 1-989-698-3068
More informationHeavy Duty Dissolved Oxygen Meter
User's Manual Heavy Duty Dissolved Oxygen Meter Model 407510 Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 FAX 781.665.0780 - TestEquipmentDepot.com Introduction Congratulations
More informationOxygen Measurement Systems High Reliability and Wide Application Coverage
Introduction High Process Efficiency Under Any Condition Oxygen Measurement Systems High Reliability and Wide Application Coverage METTLER TOLEDO provides sensors to measure dissolved oxygen (DO) in demanding
More informationHigh-speed pressure sensor Model CPT6140
Calibration technology High-speed pressure sensor Model CPT6140 WIKA data sheet CT 25.11 Applications Testing technology Calibration technology Laboratories and maintenance shops Leak and burst applications
More informationbetter measurement Simply a question of
Simply a question of better measurement SCHMIDT Flow Sensor SS 20.600 The powerful industrial professional for demanding applications involving air and gases. Industrial processes Pneumatic technology
More informationIntelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter
Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter Overview C % ppm 4~20mA Analog Output ppb Power Supply 100~240 VAC mg/l Dimensions 96 x 96 x 132mm RS-485 Digital Output (for DC-5310-RS only)
More informationHow to specify a product. Process Sensors and Mechanical Instruments
How to specify a product Process Sensors and Mechanical Instruments Keep the overview. Here is some guideline information on how to specify our products. Intended as supplementary help to specification
More informationBUYER S GUIDE AQUAlogger 530WTD
OCEAN & ENVIRONMENTAL BUYER S GUIDE AQUAlogger 530WTD Wireless Temperature and Depth Logger AQUAlogger 530WTD The AQUAlogger 530WTD has an innovative design that includes the ability to transfer stored
More informationDM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05
Battery Powered Stainless Steel Sensor class 0.05 Nominal pressure from 0 00 mbar up to 0... 00 bar Special characteristics modular sensor concept data logger graphic display stainless steel housing Ø
More informationBUYER S GUIDE AQUAlogger 520
OCEAN & ENVIRONMENTAL BUYER S GUIDE AQUAlogger 520 Mini Temperature and Pressure Logger AQUAlogger 520 Aquatec s primary temperature and depth model, the AQUAlogger 520, combines years of product development
More informationDM01. Please visit our website: Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05
DM0 Battery Powered Stainless Steel Sensor class 0.05 Nominal pressure from 0 00 mbar up to 0... 00 bar Special characteristics modular sensor concept data logger graphic display stainless steel housing
More informationC-Flow Coriolis Mass Flow Meters
Coriolis Mass Flow Meters Ready for Take Off The New Compact C-Flow Küppers Elektromechanik GmbH The C-Flow The C-Flow Coriolis Mass Meters consist of two components: KCE Transmitter KCM Transducer 2 KEM
More informationCertified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters
www.kem-kueppers.com info@kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters Description The Tricor Mass Flow Meters measure simultaneously mass
More informationIDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05
IDL0 Battery Powered Precision Digital Gauge for Leak Testing Stainless Steel Sensor class 0.05 Nominal pressure from 0 00 mbar up to 0... 00 bar Special characteristics modular sensor concept data logger
More informationTEK-SUB 4800B. Submersible Level Transmitter. Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys LEVEL
Technology Solutions TEK-SUB 4800B Submersible Level Transmitter LEVEL Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys Introduction The Tek-Sub 4800B Submersible Level Transmitter
More informationPressure transmitter PASCAL Ci4
Pressure transmitter PASCAL Ci4 for general application,type Series CI4100 Features Pressure transmitter for the measuring of relative and absolute pressures of gases, vapors and liquids High-resolution
More information973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS
Precise and Stable SF 6 Gas Analyzer Simultaneous measurement of humidity, SF 6 purity and SO 2 concentration Integrated gas recovery system with automatic pump back Fully automated SF 6 gas testing Fundamental
More informationETd 04. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. Type: ETd 04. class 0.05
Battery Powered Stainless Steel Sensor class 0.05 Nominal pressure from 0 100 mbar up to 0... 400 bar Special characteristics modular sensor concept data logger graphic display stainless steel housing
More informationUser's Manual. Heavy Duty Dissolved Oxygen Meter. Model
User's Manual Heavy Duty Dissolved Oxygen Meter Model 407510 Introduction Congratulations on your purchase of Extech's Heavy Duty Dissolved Oxygen / Temperature Meter which simultaneously displays Dissolved
More informationExperimental Research Brain oxygen monitoring: in-vitro accuracy, long-term drift and response-time of Licox- and Neurotrend sensors
Acta Neurochir (Wien) (2005) 147: 767 774 DOI 10.1007/s00701-005-0512-8 Experimental Research Brain oxygen monitoring: in-vitro accuracy, long-term drift and response-time of Licox- and Neurotrend sensors
More informationHI 2314 HI 2315 HI 23151
Instruction Manual HI 2314 HI 2315 HI 23151 Multi-Range Conductivity Meters for Laboratories www.hannainst.com Dear Customer, Thank you for choosing a Hanna Instruments product. Please read this instruction
More informationSolutions for transcutaneous monitoring
Solutions for transcutaneous monitoring About Radiometer Radiometer is a leading provider of technologically advanced acute care solutions that simplify and automate all phases of acute care testing. By
More informationBlood Parameter Monitoring System 550
Technical Compendium CDI Blood Parameter Monitoring System 550 An overview of the CDI System 550 and its industry leading technology. CDI System 550 Measures or Calculates 12 Critical Blood Parameters
More informationUser s Guide. Pressure Controller for liquid delivery systems
Flow Control User s Guide Pressure Controller for liquid delivery systems Precise Pressure Control throughout the experiment Flow control Compatible with any perfusion system Ideal for Small Volume Delivery
More informationInstruction Manual. PLT Series. 1. General Specification. 2. Installation. 3. Wiring. 4. Function. 5. Setting & Calibration
4 Digit Display, 4-20mA Output Instruction Manual (Digital Differential Pressure Transmitter) 1. General Specification 2. Installation 3. Wiring 4. Function 5. Setting & Calibration 1 4 20 1 Differential
More informationHand-held pressure calibrator with integrated pump Model CPH6600
Calibration technology Hand-held pressure calibrator with integrated pump Model CPH6600 WIKA data sheet CT 16.01 Applications Calibration service companies and service industry Measurement and control
More informationBI-680 Online Dissolved Oxygen Controller Instruction Manual
BI-680 Online Dissolved Oxygen Controller Instruction Manual BANTE INSTRUMENTS CO., LTD BI-680 Online Dissolved Oxygen Controller 1 Introduction Thank you for selecting the BI-680 online dissolved oxygen
More informationbetter measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.
Simply a question of better measurement SCHMIDT Flow Sensor SS 20.261 The cost-effective alternative in pressurised systems up to 10 bars. Compressed air technology Industrial processes A cost analysis
More informationDigital Pressure Gauge Main features: Data Sheet: DFP.418.R4.EN
Data Sheet: DFP.418.R4.EN www.ntt.dk Digital Pressure Gauge PRESSURE FORCE The DFP series digital gauges are made according to the more modern technologies in order to provide a high level of reliability,
More informationPrecision pressure sensor Basic version Model CPT6020
Calibration Precision pressure sensor Basic version Model CPT6020 WIKA data sheet CT 25.13 Applications Calibration technology High-accuracy pressure monitoring Pressure sensing in critical applications
More informationila ACTIVVE SYSTEM PLATFORM
ila ACTIVVE SYSTEM PLATFORM Custom-tailored Extrapulmonary Lung Support ila activve : Custom-Tailored Extrapulmonary gas exchange Extrapulmonary blood flow: as high as necessary as low as possible. The
More informationTEL/jlRE" Introduction. Display Features and Modes. Startup Procedure. Power-Up Procedure. Adjustment Modes
TEL/jlRE" Introduction The Telaire 7001 CO 2 /T emperature monitor (shown in Fi gt u e 1 below) is an easy to use hand-held instnunent, which provides stable and highly accurate readings due to Telaire
More informationOEM Manual MODEL 2305 ECONOMICAL DIGITAL SINGLE CYLINDER SCALE
OEM Manual MODEL 2305 ECONOMICAL DIGITAL SINGLE CYLINDER SCALE 1 These instructions generally describe the installation, operation, and maintenance of subject equipment. The manufacturer reserves the right
More informationWe measure it. For gas and water installers. testo hpa. bar
Pressure measuring instruments For gas and water installers testo 312-2 hpa testo 312-3 testo 312-4 bar C testo 312-2 / testo 312-3 Pressure meters for gas and water fitters testo 312-2 testo 312-2, fine
More informationIntracranial Pressure Sensor Testing Device
Intracranial Pressure Sensor Testing Device Detection of Shunt Malfunction in Hydrocephalus Patients Final Design Report Team Members: Brad Lindevig- BSAC Dan Miller- Team Leader Jamon Opgenorth- Communicator
More informationGas Pressure Probe. Information Sheet. Total Dissolved Gas
Total Dissolved Gas Information Sheet T900 Total Dissolved Gas Pressure Probe Description The In-Situ Inc. T900 probe is a specially adapted submersible pressure transducer designed to monitor Total Dissolved
More informationOptical Dissolved Oxygen Meter
Optical Dissolved Oxygen Meter HI764113 Rugged Optical Dissolved Oxygen Probe for Fresh and Saltwater Applications Digital, weighted probe No membranes No electrolytes No oxygen consumption No flow dependence
More informationOperating Instructions Melt Pressure Sensor
Operating Instructions Melt Pressure Sensor DA Certified to ISO 9001:2008 Please read this instruction manual carefully before installing the transducer 1 Contents: 1. Introduction 2. Operating range and
More informationHigh-performance submersible pressure transmitter For level measurement Model LH-10
Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-10 WIKA data sheet PE 81.09 Applications Level measurement in rivers and lakes Deep well
More informationD-Opto Dissolved Oxygen Sensor Operation Manual for the D-Opto 4-20mA
D-Opto Dissolved Oxygen Sensor Operation Manual for the D-Opto 4-20mA Software version 2.6 Table of contents 1 Introduction...3 1.1 Optical Sensor Technology...3 1.2 Installation...4 1.3 Operation...5
More informationSenTec OxiVenT Illuminate Ventilation and Oxygenation PCO2 PO2. Digital Transcutaneous Blood Gas Monitoring
Digital Transcutaneous Blood Gas Monitoring SenTec OxiVenT Illuminate Ventilation and Oxygenation MONTHS COMPLETE WARRANTY PCO2 PO2 Continuous Noninvasive Safe Easy to Use Accurate OxiVenT overcoming limitations
More informationRelative pressure switch type 521
Relative pressure switch type 521 Pressure range 0... 2.5 600 bar The compact type 521 pressure switch is based upon the Huba Control developed thick film technology where the pressure measuring cell is
More informationPrecision Liquid Settlement Array Manual
Precision Liquid Settlement Array Manual All efforts have been made to ensure the accuracy and completeness of the information contained in this document. RST Instruments Ltd reserves the right to change
More informationcombustion efficiency monitoring General Purpose Applications Flue gas oxygen analyzers Combustion & Environmental Monitoring An Company
combustion efficiency monitoring Flue gas oxygen analyzers General Purpose Applications Combustion & Environmental Monitoring An Company Flue Gas Oxygen Genesis is a range of flue gas analyzers for measuring
More informationOptical Dissolved Oxygen Meter
Optical Dissolved Oxygen Meter HI764113 Rugged Optical Dissolved Oxygen Probe for Fresh and Saltwater Applications Digital probe Fast and stable readings No membranes Not affected by sunlight No electrolytes
More informationIntegra Licox Brain Tissue Oxygen Monitoring
Integra Licox Brain Tissue Oxygen Monitoring REF IP2.P Directions for Use Page 3 Instrucciones de uso Página 15 Mode d emploi Page 27 Gebrauchsanleitung Seite 39 Istruzioni per l uso Pagina 51 Gebruiksaanwijzing
More informationcombustion efficiency monitoring Flue gas oxygen analyzers General Purpose Applications Combustion & Environmental Monitoring
combustion efficiency monitoring Flue gas oxygen analyzers General Purpose Applications Combustion & Environmental Monitoring Flue Gas Oxygen Genesis is a range of flue gas analyzers for measuring Oxygen
More informationMembrane covered optical CO 2 sensor
Membrane covered optical CO 2 sensor - Manual - 30 mg/l CO 2, 4-20 ma output Exclusively Distributed & Supported By: www.edaphic.com.au info@edaphic.com.au Ph: 1300 430 928 Warning! Do never try to unscrew
More informationThe affordable consumption counter for compressed air and gases R 3 /4 (DN 20)
VA 420 new The affordable consumption counter for compressed air and gases R 1 /4 (DN 8) DN 15 R 3 /4 (DN 20) DN 25 R 1 1 /4 (DN 32) DN 40 R 2 (DN 50) With mit und and ohne without Flansch flange Intelligent
More informationGasSense NDIR User Manual
INDEX INDEX... 1 1. OVERVIEW... 2 2. TECHNICAL DATA... 3 3. SPECIFICATIONS... 4 4. PRODUCT DESCRIPTION... 5 4.1 Mechanical details... 5 4.2 Piping... 7 4.3 Connections... 7 5. INSTALLATION... 10 6. CALIBRATION
More informationWHITEPAPER. Integrated process monitoring of dosing pressures
Integrated process monitoring of dosing pressures Detect and avoid errors during dosing with the flowplus 16 dosing pressure monitoring system and flowscreen Fig. 1: flowplus 16 relative pressure sensor
More informationP9000 DESCRIPTION. For parts requiring RoHS compliance, please contact factory. P February /6
P9000 High accuracy through digital compensation High thermal stability Rugged stainless steel construction Ideal for test stands High burst pressure limit DESCRIPTION The P9000 Series is a range of advanced,
More informationSTAD-D. Balancing valves Balancing valve for domestic water systems, DN Balancing valves
STAD-D Balancing valves Balancing valve for domestic water systems, DN 15-50 Balancing valves IMI TA / Balancing valves / STAD-D STAD-D The STAD-D balancing valve delivers accurate hydronic performance
More informationUser s manual for the SC32 and SC96 form-fitting recording chamber and microdrive systems
User s manual for the SC32 and SC96 form-fitting recording chamber and microdrive systems 1. Description of the chamber system ----------------------------------------- 2-3 2. Description of the microdrive
More informationMeasuring range Δp (span = 100%) Pa
4.4/ RLE 5: Volume-flow controller, continuous How energy efficiency is improved Enables demand-led volume flow control for the optimisation of energy consumption in ventilation systems. Areas of application
More informationSDI mA Pressure Transducer (Submersible + Dry) Model WL2100 Operating Manual
SDI-12 + 4-20mA Pressure Transducer (Submersible + Dry) Model WL2100 Operating Manual (Submersible) WL2100W (Dry) WL2100D QUALITY SYSTEM ISO: 9001 CERTIFIED HYQUEST SOLUTIONS PTY LTD 48-50 Scrivener St,
More informationInstallation, operating and maintenance Instructions for Seemag bypass level indicator
Issue: S Date: 05-09-14 Type G35 General information The Seetru bypass magnetic level indicator, abbreviate SEEMAG, serves to show the filling level of fluids in tanks, basins, tubes etc. The Seemag operates
More informationHigh-performance submersible pressure transmitter For level measurement Model LH-10
Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-10 WIKA data sheet PE 81.09 Applications Level measurement in rivers and lakes Deep well
More informationTechnical Data Sheet MF010-O-LC
Technical Data Sheet MF010-O-LC - 1 - 1. Properties The oxygen measuring system MF010-O-LC determines the oxygen content in gas mixtures up to a temperature of 250 C. It is particularly suitable for the
More informationPRESSURE COMPARATOR 10000PSI 700bar. Operator Instructions CRYSTAL. engineering corporation
PRESSURE COMPARATOR GauGeCaLXP 10000PSI 700bar Operator Instructions Page 2 GaugeCalXP Operator Instructions PRESSURE is Our BUSINESS Introduction Thank you for purchasing a GaugeCalXP Pressure tor from
More informationSensoric 4-20 ma Transmitter Board Operation Manual
Sensoric 4-20 ma Transmitter Board Operation Manual 1 Content Features Operation Manual Technical Data Mechanical Dimensions Remarks & Contact information 2 Features Soldered sensor cell (non replaceable)
More informationPremium Series. Economical Price & Reliable Performance. High Quality. Rust-Resistant. Long Life. Tamper-Resistant locking Screw.
Premium Series High Quality Forged Brass Body Rust-Resistant Nickel Plated Finish Long Life Corrosion Resistant Valve Seat Economical Price & Reliable Performance Tamper-Resistant locking Screw Reduces
More informationSTAD. Balancing valves DN (MD60, MD61, MD62)
STAD Balancing valves DN 15-50 (MD60, MD61, MD62) IMI TA / Balancing valves / STAD STAD The STAD balancing valve delivers accurate hydronic performance in an impressive range of applications. Ideally suited
More informationGP1 & GP2. Electropneumatic Regulators FOR PRESSURE CONTROL TO 1,000 PSI
GP1 & GP2 Electropneumatic Regulators FOR PRESSURE CONTROL TO 1, PSI GP1 & GP2 Functional Description The GP series control valve is an electronic pressure regulator designed to precisely control the pressure
More informationCO2 incubator with additional process controls
CB series 150 C2 incubators C2 incubator with additional process controls The BINDER CB series C2 incubator is the premium class among the C2 incubators. It is suitable for all sensitive incubation applications
More information86BSD Backside Digital Output
Stainless steel with O-ring seal Pressure/temperature read-out Backside digital output ASIC calibrated Absolute, gage Cable/connector option Low power option DESCRIPTION The 86BSD is a small profile, media
More informationHTD series digital differential pressure sensors
The HTD differential pressure sensors are specially developed for low pressure ranges and demanding space constrictions. The sensors allow for flexible direct manifold assemblies and offer high performance
More informationCDI System 500. Blood Parameter Monitoring System. Continuous blood parameter monitoring for improved blood gas management
CDI System 500 Blood Parameter Monitoring System Continuous blood parameter monitoring for improved blood gas management The world's most trusted and used continuous in-line blood gas monitor For more
More informationMPM426W/436W Submersible Level Transmitter
/436W Submersible Level Transmitter Features Full sealed stainless steel construction for submersible part; sensor and amplifier circuit are all in the sealed housing; protection class IP68; Aluminum-alloy
More informationSeries Environmental Chambers
3119-600 Series Environmental Chambers Challenges in Non-Ambient Testing Testing at non-ambient temperatures adds another layer of challenges to your testing laboratory. Ensuring you get accurate and stable
More informationFor Air Pressure. AP-30 Series. Digital Display & Digital Control. EASY-TO-SEE 2-color display. Two-color digital display pressure sensor
Cat No AP3-KA-C Two-color digital display pressure sensor AP-3 Series Digital Display & Digital Control For Air Pressure EASY-TO-SEE 2-color display Green and red two-color LED display clearly shows abnormal
More informationPneumatic high-pressure controller Model CPC7000
Calibration technology Pneumatic high-pressure controller Model CPC7000 WIKA data sheet CT 27.63 Applications Healthcare and avionics industry Industry (laboratory, workshop and production) Transmitter
More informationRLP100F910, F916, F918: Dual-channel volume flow controller
Product data sheet 7. 7.440 RLP00F90, F9, F98: Dual-channel volume flow controller How energy efficiency is improved For demand-based volume flow control of dual-channel systems in offices Features Optimum
More informationCATALOG NO. FIG DESCRIPTION NIB A Replacement Hose for Critikon-type devices-models 8100, 8100T, 9300XL, & 1846SX. 12
NIBP REPLACEMENT HOSES NIBP A B C D E F CATALOG NO. FIG DESCRIPTION NIB100012 A Replacement Hose for Critikon-type devices-models 8100, 8100T, 9300XL, & 1846SX. 12 NIB300012 B Replacement Hose for Criticare
More informationXMO2. Panametrics Smart Oxygen Analyzer. Applications. Features. bhge.com. An oxygen transmitter for use in:
XMO2 Panametrics Smart Oxygen Analyzer Applications An oxygen transmitter for use in: Inerting/blanketing liquid storage tanks Reactor feed gases Centrifuge gases Catalyst regeneration Solvent recovery
More informationAMS 2710 PCB pressure sensor module with V output
FEATURES Universal pressure sensor module with 0.. 10 V voltage output Fully calibrated and temperature compensated sensor module Variants for (bidirectional) differential, gage, absolute and barometric
More informationDELTI. Vac. DELTI-Vac MIL. Application. Principle. Characteristic
- MIL - presents the most complex versatile and variable system for stability Application Monitoring of chemical stability is essential for reliable risk and safety management of single or double based
More informationHUMOR 20. High-precision Humidity Calibrator HUMOR 20. Operation
High-precision Humidity Calibrator The role of humidity calibrations that are accurate, reproducible, and documentable is becoming more and more important. ISO quality guidelines and regulations according
More informationUser s Guide. Vacuum Controller for liquid delivery systems
Flow Control User s Guide Vacuum Controller for liquid delivery systems Precise Vacuum Control throughout the experiment Flow control Compatible with any perfusion system Ideal for Small Volume Delivery
More informationO2100C Oxygen Measurement Module Technical Use Notes do not use other wall adapters with the O2100Cmodule. 10% / V 5% / V 2% / V 1% / V 10% / V
O2100C Oxygen Measurement Module The O2100C module measures the partial pressure of O2 and thus the module output is proportional to the pressure in the sample cell. Gas sampled must be free of liquids
More informationAdditel 780 Series Pressure Controller
Additel 780 Series Pressure Controller Pressure ranges from vacuum to 3,000 psi (200 bar) Removable interchangeable intelligent sensors Precision accuracy of 0.005% of reading plus 0.005% of full scale
More informationOxymax COS61/COS61D. Technical Information
Technical Information Oxymax / Dissolved oxygen measurement Optical sensor acc. to the fluorescence quenching principle, with or without Memosens protocol Application The continuous measurement of the
More informationHot extractive multi-channel gas analyser for continuous process and emissions monitoring.
Product Data Sheet CODEL Continuous Emission Monitoring GCEM4100 Extractive Gas Analyser CO, CO2, NO, NO2, SO2, HCL, CH4 & H2O Hot extractive multi-channel gas analyser for continuous process and emissions
More informationFlow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25
VA 520 incl. temperature R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25 R 1 1/4 (DN 32) DN 40 R 2 (DN 50) Intelligent solutions for ac- for compressed air and gases work according to the approved calorimetric
More informationFlow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25
VA 520 incl. temperature R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25 R 1 1/4 (DN 32) DN 40 R 2 (DN 50) Intelligent solutions for ac- for compressed air and gases work according to the approved calorimetric
More informationINTRODUCING CARDIOSAVE Hybrid MORE THAN A PUMP. A REVOLUTION. SPECIFICATIONS
INTRODUCING CARDIOSAVE Hybrid MORE THAN A PUMP. A REVOLUTION. SPECIFICATIONS INTRODUCING A WHOLE NEW PARADIGM IN HEMODYNAMIC SUPPORT CARDIOSAVE represents a giant leap forward in functionality and versatility
More informationswimming pool technology
68 swimming pool technology 69 Measuring and control equipment Measuring, control and dosing systems for private swimming pools Systematic water care: Swim-tec dosing systems are responsible for controlling
More informationMPM416W/WK/WRK Submersible Level Transmitter
/WK/WRK Submersible Level Transmitter /WK/WRK Submersible Level Transmitter Features Separate construction; full sealed stainless steel construction for submersible/inserted sensor; aluminum-alloy electric
More informationFLAMMABLE GAS SENSOR/TRANSMITTER
FLAMMABLE GAS SENSOR/TRANSMITTER Plant safety protection for flammable gases. F E A T U R E S Fixed gas monitoring for point source hazards and perimeter protection in arduous duty and exposed locations.
More informationAMS 6916 Board mount pressure sensor with ratiometric analog output
FEATURES Piezoresistive pressure sensor with amplified analog output Calibrated and temperature compensated Ratiometric voltage output, 0.5 4.5 V Digital signal conditioning, 12 bit output resolution Differential,
More informationInstruction Manual Differential Pressure Transmitter
DE61 Instruction Manual Differential Pressure Transmitter Table of Contents 1. Safety Instructions 2. Intended Applications 3. Product Description and Functions 4. Installation 5. Commissioning 6. Maintenance
More informationPre-Calibrated Models
Quick Selection Guide Factory-calibrated to match thermocouple signals over selected temperature ranges For non-metal surfaces (coated metals are acceptable) For use with thermocouple input controllers,
More informationHydrostatic. Continuous level measurement. Overview Page 188 VEGAWELL 52 Page 190 VEGABAR 86, 87 Page 192 Accessory Page 196 AL-EN
Hydrostatic Continuous level measurement 8 Overview Page 188 VEGAWELL 52 Page 190 VEGABAR 86, 87 Page 192 Accessory Page 196 187 Hydrostatic Level and pressure measurement Measuring principle The pressure
More informationFor a similar sensor with o-ring mounting, refer to the 85BSD digital output pressure sensor.
Weldable or threaded process fittings Pressure/temperature read-out Digital output ASIC calibrated Absolute, gage Cable/connector option Low power option DESCRIPTION The 85BSD is a small profile, media
More informationRDO Optical Dissolved Oxygen Sensor
Manual 51A-RDO Sensor April 2010 Model RDO Sensor RDO Optical Dissolved Oxygen Sensor RDO is a registered trademark of In-Situ Inc. All rights reserved. RDO PROBE SPECIFICATIONS Wetted Materials: Delrin
More informationAdditel 780 Series Pressure Controller
Additel 780 Series Pressure Controller Pressure ranges from vacuum to 3,000 psi (200 bar) Removable interchangeable intelligent sensors Precision accuracy of 0.005% of reading plus 0.005% of full scale
More informationPressure Transmitters 36 F-27839
Pressure Transmitters 36 F-27839 SPD310/SPD360 Air Differential schneider-electric.com 37 SPD310/SPD360 SPD310/SPD360 differential pressure transmitters are intended for use in air handling systems for
More informationSUPPLIES & ACCESSORIES ELANCE
SUPPLIES & ACCESSORIES ELANCE UltraCheck Nylon Reusable Blood Pressure Cuffs NIBP Cuffs 714-4001-00 Single tube, MHP Child 13-20 cm 714-4002-00 Single tube, MHP Small Adult 18-26 cm 714-4003-00 Single
More information