READ AND SAVE THESE INSTRUCTIONS WATER TREATMENT. 200 ser ies r ever se- osmosis s y st e m s. Installation, Operation, and Maintenance Manual

Size: px
Start display at page:

Download "READ AND SAVE THESE INSTRUCTIONS WATER TREATMENT. 200 ser ies r ever se- osmosis s y st e m s. Installation, Operation, and Maintenance Manual"

Transcription

1 READ AND SAVE THESE INSTRUCTIONS WATER TREATMENT 200 ser ies r ever se- osmosis s y st e m s Installation, Operation, and Maintenance Manual

2 WARNINGS AND CAUTIONS ii DRISTEEM WATER TREATMENT SYSTEMS INSTALLATION, OPERATION, AND MAINTENANCE MANUAL...

3 Warnings and cautions WARNING Warnings and Cautions Attention installer Read this manual before installing, and leave this manual with product owner. This product must be installed by qualified HVAC and electrical contractors. Installation must be code approved. Disconnect electrical power Disconnect electrical power before installing supply wiring or performing service or maintenance procedures on any part of the system. Failure to disconnect electrical power could result in fire, electrical shock, and other hazardous conditions. These hazardous conditions could cause property damage, personal injury, or death. CAUTION Operate system at above-freezing temperatures. Operating the system at temperatures below freezing can damage the system or cause other property damage. Maintain pumping and water treatment equipment. Inadequately maintained pumping and water treatment equipment can cause the system to fail. Refer to the maintenance section of this IOM for recommended maintenance. Do not install the system using steel or galvanized-steel piping and joints. Steel and steel-galvanized piping and joints can corrode and cause system damage. Use plastic tubing and joints when assembling system. Follow all instructions in this manual to maintain product warranty. FILL IN THE FOLLOWING INFORMATION FOR YOUR RECORDS Date of purchase Customer's name Model number Serial number DRISTEEM WATER TREATMENT SYSTEMS INSTALLATION, OPERATION, AND MAINTENANCE MANUAL iii

4 Table of contents WARNINGS AND CAUTIONS ii Fill in the following information for your records iii ATTENTION INSTALLER Where to find more information OVERVIEW System specifications Flow schematic Component identification System installation Line Line Line Line Line Pre-treatment connection Series 200 controller specifications Power Inputs Outputs RO pump wiring Inlet wiring Pressure fault switch Pretreat switch Tank full switch OPERATION System operation System operation continued Initial system start-up System flush Normal operations Shutdown iv DRISTEEM WATER TREATMENT SYSTEMS INSTALLATION, OPERATION, AND MAINTENANCE MANUAL...

5 Table of contents MAINTENANCE Maintenance information Maintenance tips When to change cartridge filters When to clean membranes Membrane cleaning and preservative cartridges Membrane cleaning in the RO system How does it work? Scale cleaning cartridge Cleaning procedure Organic cleaning cartridge Cleaning procedure Membrane preservative cartridge Preserving procedure Flushing out preservative/restart procedure Tools Procedure Procedure Tools Low pressure cut-out switch Operating do's and don'ts Do Don't WARRANTY ATTENTION INSTALLER Read this manual before installing. Leave manual with product owner. DriSteem Technical Support WHERE TO FIND MORE INFORMATION Our website: The following documents are available on our web site: Water Treatment Systems Catalog Vapor-logic Controller Installation and Operation Manual DriCalc : DriCalc, our software for system sizing and selection, can be ordered at our web site. Call us at Obtaining documents from our web site or from DriCalc is the quickest way to view our literature, or we will be happy to mail literature to you. Download DriSteem literature Most DriSteem product manuals are available our website: DRISTEEM WATER TREATMENT SYSTEMS INSTALLATION, OPERATION, AND MAINTENANCE MANUAL 1

6 OVERVIEW System specifi cations Table 2-1: Pressurized RO holding tank specifications Model Hz Motor HP Volts*/Amps Phase/Frequency / VAC/5.5A ( VAC/2.8A) 1/60Hz * 115V or 230V must be ordered specifically NOTES: 1. All systems rated at 50 F (10 C) using 1000 ppm sodium chloride (NaCl) solution. System capacity decreased significantly with decrease in feed water temperature. 2. Chlorine requirements for the feed water are: a. Thin-Film (standard) 0 ppm 3. Feed water must be filtered to a turbidity of less than 1 NTU. 4. System recovery (permeate to concentrate ratio) must be maintained at the recommended level. A higher than recommended recovery will lead to a premature fouling of the membrane with a loss of permeate flow and permeate quality. Table 2-2: RO station specifications Rated capacity, permeate Model Gallons/minute Concentrate flow (reject) Gallons/minute Recirc (adjustable as needed) Gallons/minute System pressure, psi F ( C) 10/50 10/50 10/50 Pre-filters Sediment cartridge - 5 micron Carbon cartridge - 10 micron Pressure switch settings Low pressure (for pump protection) 8 psi 8 psi 8 psi 2 DRISTEEM WATER TREATMENT SYSTEMS INSTALLATION, OPERATION, AND MAINTENANCE MANUAL...

7 OVERVIEW Flow schematic FIGURE 3-1: FLOW SCHEMATIC OM-7822 DRISTEEM WATER TREATMENT SYSTEMS INSTALLATION, OPERATION, AND MAINTENANCE MANUAL 3

8 OVERVIEW Component identifi cation FIGURE 4-1: COMPONENT IDENTIFICATION a b Table 4-2: Component identification Item Description 1 Controller Power On/Off and status display 2 Inlet solenoid valve Normally closed. Opens when power is applied. 3 Cartridge filter pressure gauges (in-right/out-left) 4 Sediment filter 5 micron sediment filter. 5 Carbon filter Measure the feed and effluent pressure of the cartridge filters. Pressure difference determines when cartridge change out is required. 10 micron extruded carbon cartridge to remove chlorine and reduce organics from the feed stream. 6 Low pressure switch Shuts the system down if the inlet pressure is lower than 8 psi (adjustable). 7 High pressure pump and motor Rotary pump and motor to pressurize the incoming water. 8 Membrane modules RO membrane elements housed in stainless steel pressure tubes. 9 System pressure gauges Measure the system (feed) and concentrate (effluent) pressure of the membrane modules. 10 Concentrate control valve To adjust system pressure. Must not be completely closed when the system is in operation. 11 Recirc valve To adjust and maintain adequate flow thru membranes 12 TDS monitor Monitors the feed and permeate water quality. 12a - feed sensor; 12b - permeate sensor 13 Permeate check valve Prevents backflow into RO module. 4 DRISTEEM WATER TREATMENT SYSTEMS INSTALLATION, OPERATION, AND MAINTENANCE MANUAL...

9 INSTALLATION System installation 1. Locate RO system with adequate clearance from walls and other equipment to enable membrane servicing. 2. Run five polyvinyl tube lines to the system as follows: FIGURE 5-1: SOLENOID VALVE INLET LINE 1 Connect raw water feed supply to the solenoid valve inlet in front of the first cartridge filter housing. This will require ½ inch threaded pipe fitting and adaptor for the feed line. If desired, install an isolation valve in this line; ensure the valve opening does not restrict the water flow. LINE 2 Run a ⅜ inch line from the open end of the concentrate valve to a drain. Ensure that no liquids from other lines near this drain flow back through this line. LINE 3 Run a ⅜ inch line from one of the two permeate outlets on the back of the system to the pressurized permeate storage container. NOTE: The recirc flow line is pre-connected at the factory. LINE 4 Run a ⅜ inch line from the other permeate outlet to the humidifier or end process being fed by the system. LINE 5 Run a ¼inch line from the pressurized relief solenoid to a drain. Ensure that no liquids from other lines near this drain flow back through this line. CAUTION Pump and system performance will be adversely affected if the feed/suction line is restricted. FIGURE 5-2: RECIRC FLOW LINE CAUTION Confirm all lines are connected before plugging in unit power. DRISTEEM WATER TREATMENT SYSTEMS INSTALLATION, OPERATION, AND MAINTENANCE MANUAL 5

10 INSTALLATION System installation PRE-TREATMENT CONNECTION If you have pre-treatment equipment and you wish to shut-down the RO system during backwash or regeneration, a microswitch is required (standard with DriSteem water softeners). 1. Wire the microswitch to terminal labeled PreTreat inside controller. When the equipment goes into backwash or regeneration, the pre-treat limit switch opens and turns the power off the inlet solenoid valve, which then turns the RO pump off (and back on) when the cycle is complete. SERIES 200 CONTROLLER SPECIFICATIONS CAUTION The controller is rated for maximum 20 amp total load. Terminal strip P11 is dry contact for input signals from tank full, pressure fault and pretreat lockout. Use a small gauge 2 conductor cable for these wire connections. FIGURE 6-1: CONTROL BOARD POWER Either VAC or VAC, 1 phase, 50/60 Hz, +10/-15%, 2.5 watts Input power is auto selected INPUTS Three switch inputs, selectable normally open or normally closed OUTPUTS RO pump 1HP (based on service factor of 1.0 max) Inlet solenoid 5A 20A maximum total load NOTE: All six switches are factory set to the OFF position. Auto reset (disabled) Pressure fault retry (disabled) Tank full restart time delay (two seconds) Input contact type (NC, open to operate) If you desire to change any switch functions, move that switch to the ON position. Table 6-1: Switch positions Switch Off position On position 1 Auto reset off Auto reset on 2 Retries disabled Retries enabled 3 2 sec. restart 15 min. restart 4 N.O switches N.C. switches Switch 5 and 6 not used. 6 DRISTEEM WATER TREATMENT SYSTEMS INSTALLATION, OPERATION, AND MAINTENANCE MANUAL...

11 INSTALLATION Schematic drawing FIGURE 7-1: CONTROLLER ELECTRICAL SCHEMATIC OM-7821 DRISTEEM WATER TREATMENT SYSTEMS INSTALLATION, OPERATION, AND MAINTENANCE MANUAL 7

12 INSTALLATION Control board FIGURE 8-1: CONTROLLER ELECTRICAL SCHEMATIC Tank full RO PUMP WIRING The RO pump connects to P4 (L1) and P5 (L2) RO pump terminals. This output can operate 110/240 VAC motors up to 1HP directly. INLET WIRING The inlet solenoid valve connects to P6 (L1) and P7 (L2) inlet terminals. PRESSURE FAULT SWITCH The feed pressure switch is connected to the pressure fault input. Low pressure (factory preset 8 psi) will shut system off. PRETREAT SWITCH In systems with pretreatment, a pretreat lockout switch can be connected to the pretreat input. This switch should operate when the pretreatment device is out of service. NOTE: The output from the pretreatment device must be a dry contact and must not supply voltage. TANK FULL SWITCH DriSteem systems use a pressure switch to keep the pressurized storage tank between psi ( kpa). The switch is connected to the tank full input. 8 DRISTEEM WATER TREATMENT SYSTEMS INSTALLATION, OPERATION, AND MAINTENANCE MANUAL...

13 OPERATION System operation The unit has a single mode of operation ON with six sub-modes or states as indicated by the steady or flashing panel lights. Any light condition other than steady power ON indicates the unit is effectively in standby-mode. If there are no lights, the system is OFF and all outputs are turned off. In the operating mode, the unit operates automatically. All inputs are monitored and the outputs are controlled accordingly. Pressing the power key will toggle the unit from off to operate or from operate to off. If power is removed from the unit when power is reapplied, the unit will restart in the mode it was in when the power was removed. FIGURE 9-1: UNLOADER VALVE ON PUMP STATION When the power switch is turned ON, the center status LED will light green, the valve will open, and the RO pump will start. Under normal operation the RO unit will run until: a. the storage tank is full (right LED amber) or b. pretreat lockout has occurred (center status LED flashing green). When a or b has cleared after a time delay, the RO unit will restart and the center status LED will return to green. Switch setting three selects a two second or 15 minute tank full restart time delay. Upon an alarm signal for pressure fault, the left status LED will flash red, the RO pump will stop, and the inlet valve will close and the RO pump will turn OFF. If switch one and two are in the OFF position (disabled), the left status LED will be a steady red and the RO will not restart until the power switch has been manually cycled OFF then ON to reset the unit. If switch one is in the ON position (auto reset), every 60 minutes the RO will start and stop again if a pressure fault continues. If switch two is in the ON position (pressure fault retry), the RO will attempt to restart after 30 seconds, then five minutes, then 30 minutes. If the pressure alarm has not cleared after the third try, the RO unit will remain OFF until manually reset. Power Key: Places the controller in operating mode Pressure retry: Steady red light Pressure fault: Blinking red light Power on: Steady green light, system is operating. Pretreat: Flashing green light Tank full: Steady amber light Flush: No flush sequence If switch one and two are in the ON position after a pressure fault condition, the RO unit will continually attempt to restart after each 60 minute cycle, until the pressure switch input has cleared. DRISTEEM WATER TREATMENT SYSTEMS INSTALLATION, OPERATION, AND MAINTENANCE MANUAL 9

14 OPERATION System operation continued INITIAL SYSTEM START-UP FIGURE 10-1: CONTROL VALVES SYSTEM FLUSH Direct permeate discharge to drain for first 30 minutes of operation. 1. Connect the system to the appropriate electrical outlet, VAC or VAC 1 phase. 2. Ensure all plumbing connections are open to allow flow. Open the concentrate valve (counterclockwise). Close the recirc valve (clockwise). Ensure sufficient pressure (40 psi recommended) is in feed line. If pressure is less than 8 psi, the low pressure switch will disallow start-up until pressure is adequate. 3. Press the power button; the solenoid will open and the unit will start operating. 4. After water is flowing from the concentrate line, adjust the concentrate control valve to obtain designated flow for the specific model (see Table 2-2 on page 2). 5. If required, adjust recirc control valve to meet desired flow rates (see Table 2-2 on page 2). 6. Allow the unit to run for 30 minutes to ensure proper flushing of system. 7. After the flush time is over, press the power button OFF. 8. Redirect the permeate line to the desired location. NORMAL OPERATIONS 1. Turn the power back ON. After the pump starts, adjust the control valve to the desired flow/pressure (not to exceed 150 psi). 2. The recycle valve may now be adjusted to achieve desired recycle flow rate, ensuring concentrate flow rate is as specified. CAUTION To prevent concentrate from precipitating and causing irreversible fouling of the RO membrane, do not operate the system with the control valve completely closed. CAUTION Do not exceed recommended maximum recovery. SHUTDOWN 1. Press the power button to shut unit OFF. Close the isolation valve if it is installed on the feed line. 2. If the unit is to be shut down for more than one week, a membrane preservative should be used. To accomplish this, perform 30 second flush using cartridge filter insert (see page 14 for more information). After 30 seconds, press the power button OFF, and close the concentrate valve. This will hold the preservative in the pressure vessel. 3. When the system is restarted after an extended shutdown, follow initial system start-up procedures. 10 DRISTEEM WATER TREATMENT SYSTEMS INSTALLATION, OPERATION, AND MAINTENANCE MANUAL...

15 MAINTENANCE Maintenance information MAINTENANCE TIPS FIGURE 11-1: 4" X 10" SEDIMENT FILTER Maintain proper operating conditions: Do not exceed 150 psi on the system inlet pressure gauge. Do not over use recycle flow. This can cause premature scaling of the membrane. A proper concentrate flow is required for a long membrane life. To ensure no chlorine reaches the RO membranes, test the water from your carbon filter periodically for chlorine break through. To do this, a sample could be obtained by briefly removing the Feed TDS probe at the downstream side of the cartridge filters. Brief power ON/OFF will be needed to perform this. WHEN TO CHANGE CARTRIDGE FILTERS Cartridge filters (both sediment and carbon) should be changed regularly to maintain proper pressure and flow. DriSteem replacement part number The carbon filter removes chlorine and will exhaust its capacity over time. This is dependent upon feed source concentration and flow rate. Check chlorine removal efficiency regularly. Change the filters when the difference between the two cartridge filter pressure gauges increase by 10 psi over the initial pressure difference. For example, if initial readings are 60 psi in and 58 psi out, the difference is 2 psi. Therefore, when that difference reaches 12 psi, it is time to replace the sediment and carbon cartridges. FIGURE 11-2: 4" X 10" BIG BLUE DECHLORINATOR CARTRIDGE WHEN TO CLEAN MEMBRANES In normal operation, the membrane in reverse osmosis elements can become fouled by mineral scale, biological matter, and grime. These deposits build up during operation until it causes loss in water output or loss of salt rejection, or both. Elements should be cleaned or replaced whenever the water output rate drops by 10 percent from its initial flow rate (the flow rate established during the first 24 to 48 hours of operation) or when TDS in the product water (permeate) rises above 50. Use the factory mounted TDS sensor located on the right side of the system. It should be noted that the water output rate will drop if feed water temperature decreases (about 1.5% per F). This is normal and does not indicate membrane fouling. A malfunction in the pretreatment, pressure control or pump can cause a drop in feed water delivery pressure, feed water flow, product water output, or an increase in salt passage. If such adjustments are needed, the element may not require cleaning. DriSteem replacement part number MEMBRANE CLEANING AND PRESERVATIVE CARTRIDGES Clean and preserve membranes without removing them from your system Reduce downtime Maintain your system performance at a higher level Prolong membrane life by regular use of cleaning cartridge DRISTEEM WATER TREATMENT SYSTEMS INSTALLATION, OPERATION, AND MAINTENANCE MANUAL 11

16 MAINTENANCE Maintenance continued MEMBRANE CLEANING IN THE RO SYSTEM Membrane cleaning cartridges: Clean membranes without having to remove them from the RO system Reduce downtime Maintain the system performance at a higher level Prolong membrane life by regular use of cleaning cartridges FIGURE 12-1: 10 INCH BIG BLUE SCALE CLEANING CARTRIDGE HOW DOES IT WORK? NOTE: Clean monthly to obtain optimum results. 1. Exchange the system's pre-filter cartridge with a cleaning cartridge 2. Follow the instructions. 3. Restart the system. 4. Repeat the process if required. SCALE CLEANING CARTRIDGE DriSteem replacement part number The scale cleaning cartridge is for removal of mineral scale and build-up. CLEANING PROCEDURE 1. Shut down the RO system. 2. Disconnect permeate line and divert to drain before any cleaning cartridge is installed. 3. Remove the filter cartridge from the pre-filter housing. 4. Replace the filter cartridge with the cleaning cartridge and assemble into the filter housing. 5. Turn the system ON. After seconds, shut down the system. OPTIONAL: Instead of time, use one of the following criteria: a. Run the system until the ph of the concentrate is almost the same as the cleaning solution (ph=3) b. Permeate rate for the system drops to a very low value. 6. Let the membrane(s) soak in the cleaning solution overnight. 7. Remove the empty cleaning cartridge and replace it with the original filter. 8. Restart the system. Direct the permeate to drain for five minutes. 9. Go back to normal operations. 12 DRISTEEM WATER TREATMENT SYSTEMS INSTALLATION, OPERATION, AND MAINTENANCE MANUAL...

17 MAINTENANCE Maintenance continued ORGANIC CLEANING CARTRIDGE The organic cleaning cartridge is for removal of organics/fouling. FIGURE 13-1: 10 INCH BIG BLUE ORGANIC CLEANING CARTRIDGE CLEANING PROCEDURE 1. Shut down the RO system. 2. Disconnect permeate line and divert permeate to drain during cleaning. 3. Remove the pre-filter cartridge from the filter housing. 4. Replace the sediment pre-filter cartridge with the cleaning cartridge and assemble into the filter housing. 5. Turn the system ON. After seconds, shut down the system. OPTIONAL: Instead of time, use one of the following criteria: a. Run the system until the ph of the concentrate is almost the same as the cleaning solution (ph=10-12) b. Permeate rate for the system drops to a very low value. 6. Let the membrane(s) soak in the cleaning solution overnight. DriSteem replacement part number Remove the empty cleaning cartridge and replace it with the original filter. 8. Restart the system. Direct the permeate to drain for five minutes. 9. Go back to normal operations. DRISTEEM WATER TREATMENT SYSTEMS INSTALLATION, OPERATION, AND MAINTENANCE MANUAL 13

18 MAINTENANCE Storage To prevent bacterial growth and help maintain flux, it is recommended that elements be immersed in a preservative solution if the system will be OFF for more than one week. FIGURE 14-1: 10 INCH BIG BLUE CLEANING CARTRIDGE MEMBRANE PRESERVATIVE CARTRIDGE PRESERVING PROCEDURE 1. Shut down the RO system. 2. Disconnect the permeate line and direct permeate to drain during cleaning/preserving. 3. Remove the 5M filter cartridge from the pre-filter housing. 4. Replace the filter cartridge with the preservative cartridge and assemble into the filter housing. 5. Turn the system ON. After seconds, shut down the system. 6. Drain the system of the permeate solution as much as possible by opening a valve/fitting at a low point in the system. DriSteem replacement part number Close OFF the inlet and outlet to the membrane/system. FLUSHING OUT PRESERVATIVE/RESTART PROCEDURE 8. Open valves and put the system back in the position it was before preserving. 9. Remove the empty preservative cartridge and replace it with a new cartridge filter. 10. Restart the system. Direct permeate to drain for minutes. 11. Go back to normal operation. 14 DRISTEEM WATER TREATMENT SYSTEMS INSTALLATION, OPERATION, AND MAINTENANCE MANUAL...

19 MAINTENANCE Replacing membranes TOOLS Rubber mallet Flat blade screwdriver Open end wrench, ⅞ inch Food grade RT-111 silicone Safety glasses FIGURE 15-1: DRISTEEM REVERSE OSMOSIS MEMBRANES PROCEDURE 1. Turn OFF the RO system. 2. Relieve pressure on the membrane arry by opening the control valve. 3. Remove all lines from both ends of the pressure vessel(s). Make sure the fittings are marked so the fittings go back to the correct locations after replacing. 4. Remove u-pins from the vessel. Slowly and carefully pull the end plugs out from the fitting with a channel lock. 5. Remove end plugs by pulling carefully. DriSteem replacement part number DRISTEEM WATER TREATMENT SYSTEMS INSTALLATION, OPERATION, AND MAINTENANCE MANUAL 15

20 MAINTENANCE Replacing prefi lters PROCEDURE 1. Shut down the RO system. 2. Close field supplied inlet supply valve. 3. Turn the blue pressure housings counterclockwise. Filter cartridge should come free from the housing top and remain in the housing. 4. Remove and replace cartridges. 5. Before replacing the housing, insure the o-ring seal is lubed and placed in groove of housing. Inspect seal and replace as needed. 6. Rotate the housing clockwise until hand tight. FIGURE 16-1: PRE-FILTER Carbon filter: Primarily to remove chlorine; also removes organics and sediments down to 10 microns. 2. Sediment filter: Removes sediments and particles down to 5 micron size. 16 DRISTEEM WATER TREATMENT SYSTEMS INSTALLATION, OPERATION, AND MAINTENANCE MANUAL...

21 MAINTENANCE Adjustment of pressure switch TOOLS Flat blade screw driver LOW PRESSURE CUT-OUT SWITCH 1. Loosen nut and remove cover plate. 2. Use a box wrench to adjust nut on left side counterclockwise to lessen pressure; clockwise to raise pressure. 3. Do not tamper with the nut on the right side. 4. Replace the cover. Operating do's and don'ts DO CAUTION Pressure switch has been factory preset to 8 psi. This switch should not be adjusted unless recommended by DriSteem. CAUTION High voltage shock hazard. FIGURE 17-1: LOW PRESSURE CUT-OUT SWITCH 1. Change the cartridge filters regularly. 2. Monitor the system and keep a daily log. 3. Run the system as much as possible, on a continuous basis. 4. Adjust the system recovery to recommend value. DON'T 1. Permit chlorine in the feed water. 2. Shut down the system for extended periods without preserving the membranes. 3. Close the concentrate control valve completely. 4. Operate the system with insufficient feed flow. DRISTEEM WATER TREATMENT SYSTEMS INSTALLATION, OPERATION, AND MAINTENANCE MANUAL 17

22 MAINTENANCE System monitoring and record keeping The system should be monitored and all pertinent data recorded on a daily basis. This includes cartridge filter pressure in/out, system pressure in/out, flow and water quality (TDS) in/out. Data is needed to determine operating efficiency and for performing system maintenance. The latter includes cleaning of the membranes, adjusting the operating conditions as well as replacement of cartridge filters and RO membranes. Table 18-1: Troubleshooting Issue Possible Cause Solution Inlet pressure low Low supply pressure Correct incoming supply pressure Cartridge filters plugged Solenoid valve malfunction Change filters Replace solenoid valve and/or coil Permeate flow low Low water temperature Adjust water temperature Low system pressure Membranes fouled Adjust concentrate control valve Clean membranes Pump noisy Low inlet flow See "Inlet pressure low" Permeate quality poor Low inlet flow Adjust concentrate control valve Low system pressure Recovery too high Membranes fouled Membranes damaged See "Inlet pressure low" Reduce recovery Clean membranes Replace membranes 18 DRISTEEM WATER TREATMENT SYSTEMS INSTALLATION, OPERATION, AND MAINTENANCE MANUAL...

23 MAINTENANCE System operating log Table 19-1: System operating log Date Time Chlorine Cartridge in psi Cartridge out psi Water temperature TDS in TDS out System psi Concentrate psi Cartrdige filter change Membrane change Recorded by Notes DRISTEEM WATER TREATMENT SYSTEMS INSTALLATION, OPERATION, AND MAINTENANCE MANUAL 19

24 WARRANTY Expect quality from the industry leader Since 1965, DriSteem has led the industry with innovative methods for humidifying and cooling air with precise control. Our focus on ease of ownership is evident in the design of our Water Treatment Systems, which feature low maintenance and comprehensive control. DriSteem also leads the industry with a Twoyear Limited Warranty and optional extended warranty. For more information sales@dristeem.com For the most recent product information visit our Web site: DRI-STEEM Corporation a subsidiary of Research Products Corporation DriSteem is an ISO 9001:2000 certified company U.S. Headquarters: Technology Drive Eden Prairie, MN or (fax) Two-year Limited Warranty DRI-STEEM Corporation ( DriSteem ) warrants to the original user that its products will be free from defects in materials and workmanship for a period of two (2) years after installation or twentyseven (27) months from the date DriSteem ships such product, whichever date is the earlier. If any DriSteem product is found to be defective in material or workmanship during the applicable warranty period, DriSteem s entire liability, and the purchaser s sole and exclusive remedy, shall be the repair or replacement of the defective product, or the refund of the purchase price, at DriSteem s election. DriSteem shall not be liable for any costs or expenses, whether direct or indirect, associated with the installation, removal or reinstallation of any defective product. The Limited Warranty does not include cylinder replacement for electrode steam humidifiers. DriSteem s Limited Warranty shall not be effective or actionable unless there is compliance with all installation and operating instructions furnished by DriSteem, or if the products have been modified or altered without the written consent of DriSteem, or if such products have been subject to accident, misuse, mishandling, tampering, negligence or improper maintenance. Any warranty claim must be submitted to DriSteem in writing within the stated warranty period. Defective parts may be required to be returned to DriSteem. DriSteem s Limited Warranty is made in lieu of, and DriSteem disclaims all other warranties, whether express or implied, including but not limited to any IMPLIED WARRANTY OF MERCHANTABILITY, ANY IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, any implied warranty arising out of a course of dealing or of performance, custom or usage of trade. DriSteem SHALL NOT, UNDER ANY CIRCUMSTANCES BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, LOSS OF PROFITS, REVENUE OR BUSINESS) OR DAMAGE OR INJURY TO PERSONS OR PROPERTY IN ANY WAY RELATED TO THE MANUFACTURE OR THE USE OF ITS PRODUCTS. The exclusion applies regardless of whether such damages are sought based on breach of warranty, breach of contract, negligence, strict liability in tort, or any other legal theory, even if DriSteem has notice of the possibility of such damages. By purchasing DriSteem s products, the purchaser agrees to the terms and conditions of this Limited Warranty. Extended warranty The original user may extend the term of the DriSteem Limited Warranty for a limited number of months past the initial applicable warranty period and term provided in the first paragraph of this Limited Warranty. All the terms and conditions of the Limited Warranty during the initial applicable warranty period and term shall apply during any extended term. An extended warranty term of an additional twelve (12) months or twenty four (24) months of coverage may be purchased. The extended warranty term may be purchased until eighteen (18) months after the product is shipped, after which time no extended warranties are available. Any extension of the Limited Warranty under this program must be in writing, signed by DriSteem, and paid for in full by the purchaser. mc_051308_0630 European office: Grote Hellekensstraat 54 b B-3520 Zonhoven Belgium (voice) dristeem-europe@dristeem.com Continuous product improvement is a policy of DriSteem; therefore, product features and specifications are subject to change without notice. DriSteem and Vapor-logic are registered trademarks of Research Products Corporation and are filed for trademark registration in Canada and the European community. Product and corporate names used in this document may be trademarks or registered trademarks. They are used for explanation only without intent to infringe Research Products Corporation Form No. WTS-200-IOM-E-0115 Part No Rev A

BLS 1900 Optimum REVERSE OSMOSIS SYSTEM

BLS 1900 Optimum REVERSE OSMOSIS SYSTEM Installation, Operation, and Maintenance Manual BLS 1900 Optimum REVERSE OSMOSIS SYSTEM JANUARY 2019 Table of Contents 3. BLS Reverse Osmosis System Introduction 3. How Reverse Osmosis Works 3. Definitions

More information

Accu-Tab Systems 1000 Series by Axiall Corporation

Accu-Tab Systems 1000 Series by Axiall Corporation Accu-Tab Systems 1000 Series by Axiall Corporation Installation and Operating Instructions Model 1050 DANGER: DO NOT MIX CHEMICALS! The Accu-Tab chlorinator is designed for use with Axiall approved tablets

More information

SpectraPure PUMPED RO SYSTEMS (PSP) User s Manual for PSP-1500 Systems

SpectraPure PUMPED RO SYSTEMS (PSP) User s Manual for PSP-1500 Systems SpectraPure PUMPED RO SYSTEMS (PSP) User s Manual for PSP-1500 Systems 2 3 PSP-1500 SYSTEM DESCRIPTION Reverse Osmosis RO Reverse Osmosis utilizes the unique properties of a semi-permeable membrane to

More information

FlashGARD HP Reverse Osmosis Filtration System Model Number FSTMO75 Part Number

FlashGARD HP Reverse Osmosis Filtration System Model Number FSTMO75 Part Number 3M Water Filtration Products FlashGARD HP Reverse Osmosis Filtration System Model Number FSTMO75 Part Number 56123-06 Installer: Please leave this manual with owner/operator. End User: Please retain for

More information

Installation & Instruction Manual For Portable Series R.O. units:

Installation & Instruction Manual For Portable Series R.O. units: Installation & Instruction Manual For Portable Series R.O. units: Please read carefully before proceeding with installation *System components and appearance may vary from above image. REPLACEMENT AND

More information

Accu-Tab Systems 2000 P Series by Axiall Corporation

Accu-Tab Systems 2000 P Series by Axiall Corporation Accu-Tab Systems 2000 P Series by Axiall Corporation Installation and Operating Instructions Models 2075 P 2150 P For NSF/ANSI-Standard 61 NSF STANDARD 61 applications use NSF/ANSI Standard 60 listed Axiall

More information

Accu-Tab PowerBase 3012AT by Axiall Corporation

Accu-Tab PowerBase 3012AT by Axiall Corporation Accu-Tab PowerBase 3012AT by Axiall Corporation Installation and Operating Instructions DANGER: DO NOT MIX CHEMICALS! The PowerBase 3012AT chlorinator system is designed for use with Axiall Corp. approved

More information

Operating Manual. Model BAC-30RT30/BAC-30DC

Operating Manual. Model BAC-30RT30/BAC-30DC Model BAC-30RT30/BAC-30DC Manual No. BAC012 (Rev 1 October 2002) Operating Manual AIR SYSTEMS INTERNATIONAL, INC. 829 Juniper Crescent, Chesapeake, Va., 23320 Telephone (757) 424-3967 Toll Free 1-800-866-8100

More information

Accu-Tab PowerBase 3070AT by Axiall Corporation

Accu-Tab PowerBase 3070AT by Axiall Corporation Accu-Tab PowerBase 3070AT by Axiall Corporation Installation and Operating Instructions The PowerBase 3070AT Chlorinator is NSF STD 50 NSF-Listed for pool applications. ONLY Axiall Corp. Accu-Tab Blue

More information

GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP

GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP LIMITED WARRANTY Getz Equipment Innovators warrants its products, and component parts of any product manufactured by

More information

Light Commercial Reverse Osmosis System. EE-1000 Manual

Light Commercial Reverse Osmosis System. EE-1000 Manual Light Commercial Reverse Osmosis System EE-1000 Manual Nimbus Water Systems 41840 McAlby Court, Suite A Murrieta, CA 92562 800-451-9343 Fax 951-894-2801 www.nimbuswater.com Nimbus Water Systems 1 EE-1000

More information

Acid- Rite ph Adjustment System 2500 by Axiall, a Westlake Company

Acid- Rite ph Adjustment System 2500 by Axiall, a Westlake Company Acid- Rite ph Adjustment System 2500 by Axiall, a Westlake Company Installation and Operating Instructions DANGER: DO NOT MIX CHEMICALS! The Acid-Rite ph Adjustment System is designed for use with Axiall

More information

1020 Industrial Drive, Orlinda, TN fax

1020 Industrial Drive, Orlinda, TN fax Operation Manual Ultrafiltration for High Purity Distribution K-A-HPTUF Series 615-654-4441 sales@specialtyh2o.com 615-654-4449 fax TABLE OF CONTENTS Section 1 GENERAL 1.1 Warnings and Cautions... 1 1.2

More information

SSFU SUPER SPRAYFAST UNIVERSAL ADHESIVE APPLICATOR

SSFU SUPER SPRAYFAST UNIVERSAL ADHESIVE APPLICATOR S S F U SSFU SUPER SPRAYFAST UNIVERSAL ADHESIVE APPLICATOR MACHINERY DIVISION OWNER S MANUAL UNIT INSTRUCTIONS Please follow all SSFU Safety Instructions. Contact your Duro Dyne Tech Service if you have

More information

TOP VALVE. Pat. #5,857,486 & 5,944,050. High Temperature: max. 300 F (149 C) Back Pressure And Pressure Relief Valves. Instruction Manual

TOP VALVE. Pat. #5,857,486 & 5,944,050. High Temperature: max. 300 F (149 C) Back Pressure And Pressure Relief Valves. Instruction Manual TOP VALVE Pat. #5,857,486 & 5,944,050 High Temperature: max. 300 F (149 C) Back Pressure And Pressure Relief Valves Instruction Manual PLEASE NOTE: This instruction manual provides information and instructions

More information

MN-800-TF REVERSE OSMOSIS TREATMENT SYSTEM OWNERS MANUAL

MN-800-TF REVERSE OSMOSIS TREATMENT SYSTEM OWNERS MANUAL MN-800-TF REVERSE OSMOSIS TREATMENT SYSTEM OWNERS MANUAL Nimbus Water Systems 41840 McAlby Court, Suite A Murrieta, CA 92562-7036 800-451-9343 THE NIMBUS MN-800 TF REVERSE OSMOSIS TREATMENT SYSTEM TABLE

More information

User Instruction Manual

User Instruction Manual User Instruction Manual 4500 psi Air Compressor Ver 2, 1.18 Contents Parts Included...3 Assembly Instructions...3-5 Operation Instructions...6-7 Oil Change Intervals...8 Air Filter Replacement...9 Setting

More information

PROPORTIONING VALVE. Model 150 INSTRUCTION MANUAL. March 2017 IMS Company Stafford Road

PROPORTIONING VALVE. Model 150 INSTRUCTION MANUAL. March 2017 IMS Company Stafford Road PROPORTIONING VALVE Model 150 INSTRUCTION MANUAL March 2017 IMS Company 10373 Stafford Road Telephone: (440) 543-1615 Fax: (440) 543-1069 Email: sales@imscompany.com 1 Introduction IMS Company reserves

More information

PC1131 Electric Air Compressor

PC1131 Electric Air Compressor Senco Products Inc. 8485 Broadwell Road Cincinnati, Ohio 45244 PC1131 Electric Air Compressor Operating Instructions C US 2006, 2007 by Senco Products, Inc. Warnings for the safe use of this tool are included

More information

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual Installation, Operation and Maintenance Manual Model H2F H2Flow Anti-Scale System Chemical-Free, Salt-Free Scale Prevention Introduction The H2Flow Anti-Scale System will condition the tap water providing

More information

TOP VALVE. Pat. #5,857,486 & 5,944,050. Mid-Range Pressure PSIG Back Pressure and Pressure Relief Valves. Instruction Manual

TOP VALVE. Pat. #5,857,486 & 5,944,050. Mid-Range Pressure PSIG Back Pressure and Pressure Relief Valves. Instruction Manual TOP VALVE Pat. #5,857,486 & 5,944,050 Mid-Range Pressure 50 232 PSIG Back Pressure and Pressure Relief Valves Instruction Manual Please Note: This instruction manual provides detailed information and instructions

More information

Pure Water Power Purification System 4-Stage RODI Operations Manual

Pure Water Power Purification System 4-Stage RODI Operations Manual Pure Water Power Purification System 4-Stage RODI Operations Manual Flush Valve Lever Quick Disconnect for RO Water Testing Water Supply In Drain Hose Pure Water Out to Waterfed Pole New Machine Setup

More information

WATER HEATER THERMAL EXPANSION TANKS Owner s Manual. Safety Instructions Installation Maintenance Warranty. Models: 2-5 Gallon Capacity

WATER HEATER THERMAL EXPANSION TANKS Owner s Manual. Safety Instructions Installation Maintenance Warranty. Models: 2-5 Gallon Capacity WATER HEATER THERMAL EXPANSION TANKS Owner s Manual Safety Instructions Installation Maintenance Warranty Models: 2-5 Gallon Capacity Thank You for purchasing this Thermal Expansion Tank. Properly installed

More information

Vessel Installation and Operating Manual

Vessel Installation and Operating Manual For In-ground and Aboveground Pools Vessel Installation and Operating Manual Important Safety Information Please read this manual prior to installation. Nature 2 Express is designed to sanitize in-ground

More information

ROPV R40 E Series User Manual

ROPV R40 E Series User Manual HARBIN ROPV INDUSTRY DEVELOPMENT CENTER ROPV R40 E Series User Manual For Use with the Following ROPV Pressure Vessel Models: R40 300E R40 450E Headquarters Tel:(+86)451-82267301 Fax:(+86)451-82267303

More information

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289 3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS Item #31289 The EASTWOOD 3 GALLON, OILLESS PANCAKE COMPRESSOR, with an Integral Air Regulator, efficiently supplies all compressed air requirements for

More information

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model 50-P-Mini Portable Systems Outfitted with ABM-725 Monitor

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model 50-P-Mini Portable Systems Outfitted with ABM-725 Monitor INSTALLATION and INSTRUCTION MANUAL for QUALITY AIR BREATHING SYSTEMS Model 50-P-Mini Portable Systems Outfitted with ABM-725 Monitor M A R T E C H S E R V I C E S C O M P A N Y P.O. Box 7079 OFFICE: (507)

More information

Compact Triple Cabinet Outlet Station Model Installation and Operating Instructions

Compact Triple Cabinet Outlet Station Model Installation and Operating Instructions Compact Triple Cabinet Outlet Station Model 6258-1 Installation and Operating Instructions The Porter Compact Triple Outlet Station (6258-1) provides a quick, safe, and reliable method of connection to

More information

R E D I C O N T R O L S

R E D I C O N T R O L S R E D I C O N T R O L S Operation & Maintenance Manual Portable Service Purger for Low Pressure Chillers Model: PSP-LP-1B For Refrigerants R-11, R-113, R-114 & R-123 & Other Similar Refrigerants File Literature

More information

ACCU-MIX 1200 / / 26270

ACCU-MIX 1200 / / 26270 ACCU-MIX 1200 / 14100 / 26270 Model 102006 (1200) Model 102002 (14100) Model 102003 (26270) Pre filter is required when the water supply is from a in house un filtered well to retain the warranty. Pre

More information

Compact Triple Cabinet Outlet Station Model B Installation and Operating Instructions

Compact Triple Cabinet Outlet Station Model B Installation and Operating Instructions PORTER Parker Hannifin Corporation Porter Instrument Division 245 Township Line Rd. P.O. Box 907 Hatfield, PA 19440-0907 USA (215) 723-4000 / fax (215) 723-5106 Compact Triple Cabinet Outlet Station Model

More information

BS Series Basket Strainer

BS Series Basket Strainer BS Series Basket Strainer Operating, Installation, & Maintenance Manual Corrosion Resistant Fluid and Air Handling Systems. Dated 04-26-12 PRESSURE DROP SIMTECH strainers are engineered to offer the lowest

More information

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1.

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1. 2 GALLON TWIN STACK AIR COMPRESSOR Model: 9526 DO NOT RETURN TO STORE. Please CALL 800-348-5004 for parts and service. CALIFORNIA PROPOSITION 65 WARNING: You can create dust when you cut, sand, drill or

More information

U S E R M A N U A L CAUTION. SAVE THESE INSTRUCTIONS Federal (USA) law restricts this device to sale by or on the order of a physician.

U S E R M A N U A L CAUTION. SAVE THESE INSTRUCTIONS Federal (USA) law restricts this device to sale by or on the order of a physician. U S E R M A N U A L 1600 SERIES OXYGEN REGULATOR 168715G (Shown) SAVE THESE INSTRUCTIONS Federal (USA) law restricts this device to sale by or on the order of a physician. 300 Held Drive Tel: (+001) 610-262-6090

More information

Iron Filter Installation / Operation Manual

Iron Filter Installation / Operation Manual Iron Filter Installation / Operation Manual BrassMaster and BrassMaster Plus Technical Video Library: http://watercontrolinc.com/residential-technical-support/residential-technical-videos BrassMaster technical

More information

INSTRUCTION MANUAL FOR MODEL 7360V VERTICAL CURING CHAMBER Revision E May

INSTRUCTION MANUAL FOR MODEL 7360V VERTICAL CURING CHAMBER Revision E May INSTRUCTION MANUAL FOR MODEL 7360V VERTICAL CURING CHAMBER Revision E May 2015 98-0520 S/N 2001 N. Indianwood Ave. Tulsa, Oklahoma 74012 U.S.A. TEL: (918) 250-7200 FAX: (918) 459-0165 E-mail: chandler.sales@ametek.com

More information

TOMAR TSM-E SERIES (400, 800 & 1200 GPD) REVERSE OSMOSIS TREATMENT SYSTEM OWNER S MANUAL

TOMAR TSM-E SERIES (400, 800 & 1200 GPD) REVERSE OSMOSIS TREATMENT SYSTEM OWNER S MANUAL TOMAR TSM-E SERIES (400, 800 & 1200 GPD) REVERSE OSMOSIS TREATMENT SYSTEM OWNER S MANUAL Tomar Water Systems Inc. 804 North Twin Oaks Valley Road #118 San Marcos, CA 92069 TSM-Eman 07/18 TOMAR TSM-E R.O.

More information

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE INSTALLATION, OPERATION & MAINTENANCE MANUAL INTERFACE DEVICES, INC. 230 Depot Road, Milford, CT 06460 Ph: (203) 878-4648, Fx: (203) 882-0885, E-mail: info@interfacedevices.com

More information

TL-12 FLUSH TANK. Manual Ref. # MN-??? Polyurethane Machinery Corp. REVISION 1.0

TL-12 FLUSH TANK. Manual Ref. # MN-??? Polyurethane Machinery Corp. REVISION 1.0 TL-12 FLUSH TANK Manual Ref. # MN-??? REVISION 1.0 Polyurethane Machinery Corp. Corporate: 1 Komo Dr, Lakewood, NJ 08701 Manufacturing: 2 Komo Dr, Lakewood, NJ 08701 Phone: 732-415-4400 Fax: 732-364-4025

More information

Yoke Block Instruction Manual

Yoke Block Instruction Manual Yoke Block Instruction Manual ! WARNING IMPORTANT: READ MANUAL COMPLETELY BEFORE OPERATING THIS DEVICE This manual contains instructions on periodically required checks to be performed by the user. These

More information

4 and 8 Station PDS Control Installation & Operators Manual

4 and 8 Station PDS Control Installation & Operators Manual 4 and 8 Station PDS Control Installation & Operators Manual 1402-15 11/2000 June 2003 MW1402C Chore-Time Warranty 4 and 8 Station PDS Control Chore-Time Warranty Chore-Time Equipment ( Chore-Time ) warrants

More information

AC1810 / AC1810-A TECHNICAL SPECIFICATIONS. Operating Pressure psi ( kgs/cm²) [AC1810] Displacement. Net Weight

AC1810 / AC1810-A TECHNICAL SPECIFICATIONS. Operating Pressure psi ( kgs/cm²) [AC1810] Displacement. Net Weight Technical Specifications Operating Instructions Maintenance Information Troubleshooting Guide Parts Diagrams AC1810 / AC1810-A THE EVOLUTION OF PERFECTION CAUTION: Before attempting to use or service this

More information

AMP Oil Free Manual AMP 50-8-TC AMP 50-6-D AMP General User and Maintenance Instructions

AMP Oil Free Manual AMP 50-8-TC AMP 50-6-D AMP General User and Maintenance Instructions AMP Oil Free Manual AMP 50-8-TC AMP 50-6-D AMP 50-24 General User and Maintenance Instructions Silentaire Technology 8614 Veterans Memorial Dr. Houston, TX 77088 800-972-7668 Fax 832-327-0669 www.silentaire.com

More information

This Page Intentionally Left Blank 2

This Page Intentionally Left Blank 2 Reverse Osmosis User s Manual Model M2-4240, M2-6240, M2-8240, M2-10240, M2-12240 M2-12240 Pictured This Page Intentionally Left Blank 2 TABLE OF CONTENTS INTRODUCTION... 4 SAFETY... 4 FEED WATER AND OPERATION

More information

Commercial Well Tank Installation Instructions

Commercial Well Tank Installation Instructions West Warwick, Rhode Island 02893 Telephone 401-884-6300 INSTALLATION, OPERATION & SERVICE INSTRUCTIONS COMMERCIAL WELL-X-TROL WX-401(C) through WX-407(C) WX-447(C) through WX-457(C) WX-421 through WX-427

More information

Yoke Block Instruction Manual

Yoke Block Instruction Manual Yoke Block Instruction Manual ! WARNING IMPORTANT: READ MANUAL COMPLETELY BEFORE OPERATING THIS DEVICE This manual contains instructions on periodically required checks to be performed by the user. These

More information

Marschalk Model # 94000

Marschalk Model # 94000 Marschalk Model # 94000 12-volt DC Portable oil-less Air Compressor Operation Manual 27250006 REV 1 9/13/05 Table of Contents CHAPTER 1: SYSTEM DESCRIPTION... 5 FUNCTION AND THEORY... 5 SYSTEM COMPONENTS...

More information

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST OIL-LESS TYPE IMPORTANT: PLEASE READ CAREFULLY BEFORE STARTING OPERATIONS. THE CONTENTS ARE FOR GENERAL INFORMATION OF ALL THE SIMILAR MODELS. Record

More information

IonGen. Installation Instructions & Maintenance Owner s Manual. Electronic Clarifier for Ponds and Pondless Waterfall Systems

IonGen. Installation Instructions & Maintenance Owner s Manual. Electronic Clarifier for Ponds and Pondless Waterfall Systems IonGen Installation Instructions & Maintenance Owner s Manual Electronic Clarifier for Ponds and Pondless Waterfall Systems Made in U.S.A. Aquascape, Inc. St. Charles, IL 60174 Brampton, ON L6T 5V7 www.aquascapeinc.com

More information

Operating Manual. Models AQT-02 & AQT-COO2 Manual No. MON004 (Rev 2 April 2000)

Operating Manual. Models AQT-02 & AQT-COO2 Manual No. MON004 (Rev 2 April 2000) Models AQT-02 & AQT-COO2 Manual No. MON004 (Rev 2 April 2000) Operating Manual AIR SYSTEMS INTERNATIONAL, INC. 829 Juniper Crescent, Chesapeake, Va., 23320 Telephone (757) 424-3967 Toll Free 1-800-866-8100

More information

Reverse Osmosis System Installation Guide and Operation Manual.

Reverse Osmosis System Installation Guide and Operation Manual. Reverse Osmosis System Installation Guide and Operation Manual. Table of Contents 1 Introduction...2 2 Installation...3 2.1 Feed water connection...3 2.2 Permeate and concentrate plumbing...3 2.3 Electrical

More information

Installation and Operating Manual

Installation and Operating Manual Safety Instructions Important Information Please read prior to installation ATTENTION! ELECTRICAL HAZARD FOR INGROUND POOLS AND ABOVEGROUND POOLS Installation and Operating Manual IMPORTANT Pool Owner,

More information

Electronic Control Pump Instruction Manual

Electronic Control Pump Instruction Manual Limited Warranty G2 Products manufactured by Walrus Pumps Co (Walrus) are warranted to the first user only to be free of defects in material and workmanship for a period of 2 months from date of installation,

More information

Owner s Manual AMERICAN. LiquaGen 5 Stage (RO/DI) Aquarium Reef System. YEAR Y 1

Owner s Manual AMERICAN. LiquaGen 5 Stage (RO/DI) Aquarium Reef System.   YEAR Y 1 Owner s Manual A NT HENTI AMERICAN Y 1 UT C WARR AR A 1-Y E LiquaGen 5 Stage (RO/DI) Aquarium Reef System YEAR MANUFACTURER WARRANTY Welcome to the LiquaGen experience and thank you for purchasing our

More information

RAM 4021 Operation Manual

RAM 4021 Operation Manual RAM 4021 Operation Manual Worldwide Manufacturer of Gas Detection Solutions TABLE OF CONTENTS RAM 4021 For your safety...3 Description...3 Set-up mode...4 Annunciator lights/alarms...4 Operation...5 Calibration...6

More information

INSTALLATION INSTRUCTION

INSTALLATION INSTRUCTION ULTIMATE Countertop REVERSE OSMOSIS SYSTEM INSTALLATION INSTRUCTION & OWNER S MANUAL Ver 2.4 www.freedrinkingwater.com All Rights Reserved APEC Water Systems Please keep this Owner s Manual for future

More information

OPERATIONS MANUAL. Ultra Pure Systems HydroTube. Reverse Osmosis/Deionizing water production machines designed for water fed pole window cleaning.

OPERATIONS MANUAL. Ultra Pure Systems HydroTube. Reverse Osmosis/Deionizing water production machines designed for water fed pole window cleaning. Ultra Pure Systems HydroTube Reverse Osmosis/Deionizing water production machines designed for water fed pole window cleaning. OPERATIONS MANUAL 3650 Dodd Rd Eagan, MN 55123 651.686.5399 Fax 651.686.5695

More information

200 PSI FAST-FILL AIR SOURCE KIT

200 PSI FAST-FILL AIR SOURCE KIT 200 PSI FAST-FILL AIR SOURCE KIT 55% Duty Compressor on 2.0 Gallon Air Tank PART NO. 20007 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of

More information

200 PSI HIGH-FLOW AIR SOURCE KIT

200 PSI HIGH-FLOW AIR SOURCE KIT 200 PSI HIGH-FLOW AIR SOURCE KIT 50% Duty Compressor on 2.0 Gallon Air Tank PART NO. 20008 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of

More information

SPECIFICATIONS APCEPH1

SPECIFICATIONS APCEPH1 APCEPH1 ph CONTROLLER SPECIFICATIONS APCEPH1 Input voltage 120 Volts AC Maximum amperage 14.5 amps @ 120 VAC ph Accuracy +/- 0.2 ph ph Control range Adjustable 4.5 8.5 ph Weight < 1 lbs Dimensions 3" x

More information

120 PSI FAST-FILL AIR SOURCE KIT 25% Duty Compressor on 1.5 Gallon Air Tank

120 PSI FAST-FILL AIR SOURCE KIT 25% Duty Compressor on 1.5 Gallon Air Tank 120 PSI FAST-FILL AIR SOURCE KIT 25% Duty Compressor on 1.5 Gallon Air Tank PART NO. 20003 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of

More information

ChlorMaker DO OPERATING INSTRUCTIONS DO - DRAPE OVER

ChlorMaker DO OPERATING INSTRUCTIONS DO - DRAPE OVER ChlorMaker DO TM DO - DRAPE OVER OPERATING INSTRUCTIONS ControlOMatic, Inc. 12659 Arbor Lane, Grass Valley, CA 95949 www.controlomatic.com Support@ControlOMatic.com 530-205-4520 Manual Version: 1/1/13

More information

NIV EAU MATIC ST User Manual Made in Canada

NIV EAU MATIC ST User Manual Made in Canada NIV EAU MATIC ST User Manual Made in Canada www.niveaumatic.com info@niveaumatic.com -2- Table of contents Introduction Section 1 Page 4 Installation Section 2 Pages 5 to 10 2.1 Control box 2.2 Sensor

More information

SPECIFICATIONS ATTENTION

SPECIFICATIONS ATTENTION VPS 504 S06 Installation Manual - P/N 80122 - Ed. 01/09 VPS 504 S06 and S05 Valve Proving System Installation Instructions VPS 1 6 Gases Natural gas, air and other inert gases. NOT suitable for butane

More information

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units Models: EPS Single Pump EPT Twin Pump EPS-HP EPT-HP Single Pump High Pressure Twin Pump High Pressure

More information

MODEL NUMBER: PSI AIR SOURCE KIT 200 PSI Compressor on 2.0 Gallon 200 PSI Air Tank

MODEL NUMBER: PSI AIR SOURCE KIT 200 PSI Compressor on 2.0 Gallon 200 PSI Air Tank IMPORTANT SAFETY INSTRUCTIONS CAUTION - To reduce risk of electrical shock or Electrocution: MODEL NUMBER: 20008 200 PSI AIR SOURCE KIT 200 PSI Compressor on 2.0 Gallon 200 PSI Air Tank IMPORTANT: It is

More information

This Page Intentionally Left Blank 2

This Page Intentionally Left Blank 2 Reverse Osmosis User s Manual Model M1-4240, M1-6240, M1-8240, M1-10240, M1-12240 M1-12240 Pictured This Page Intentionally Left Blank 2 TABLE OF CONTENTS INTRODUCTION... 4 SAFETY... 4 FEED WATER AND OPERATION

More information

SC HYDRAULIC ENGINEERING CORPORATION

SC HYDRAULIC ENGINEERING CORPORATION Designers and Manufacturers of Hydraulic and Pneumatic Equipment SC HYDRAULIC ENGINEERING CORPORATION 1130 Columbia Street - Brea, California 92821 - USA Phone (714) 257-4800 - Fax (714) 257-4810 V FLOW

More information

Standard Gas Countertop Griddle

Standard Gas Countertop Griddle Standard Gas Countertop Griddle This manual contains important information regarding your unit. Please read the manual thoroughly prior to equipment set-up, operation and maintenance. Failure to comply

More information

MODEL NUMBER: M20005 AIR SOURCE KIT. 30% Duty Compressor on. 2.0 Gallon Air Tank SAVE THIS MANUAL FOR FUTURE REFERENCE

MODEL NUMBER: M20005 AIR SOURCE KIT. 30% Duty Compressor on. 2.0 Gallon Air Tank SAVE THIS MANUAL FOR FUTURE REFERENCE MODEL NUMBER: M20005 AIR SOURCE KIT 30% Duty Compressor on 2.0 Gallon Air Tank SAVE THIS MANUAL FOR FUTURE REFERENCE USER MANUAL IMPORTANT SAFETY INSTRUCTIONS CAUTION - To reduce risk of electrical shock

More information

Installation, Operation, and Maintenance Manual

Installation, Operation, and Maintenance Manual Installation, Operation, and Maintenance Manual Product Preservers Anti-Scale System Chemical-Free, Salt-Free Scale Prevention Introduction The Product Preservers Anti-Scale System will condition the tap

More information

Model C Pipe Line Strainer 6, 8 & 10 Inch (DN150, DN200 & DN250) 250 psi (17,2) General Description. Technical Data. Page of 6 MAY, 2006 TFP1644

Model C Pipe Line Strainer 6, 8 & 10 Inch (DN150, DN200 & DN250) 250 psi (17,2) General Description. Technical Data. Page of 6 MAY, 2006 TFP1644 Technical Services: Tel: (00) 31-9312 / Fax: (00) 791-5500 Model C Pipe Line Strainer 6, & 10 Inch (150, & 250) 250 psi (17,2) General Description The welded steel body Model C Pipe Line Strainers (Ref.

More information

SPECIFICATIONS TABLE Maximum Air Pressure 115 PSI Air Tank Capacity 20 Gallons

SPECIFICATIONS TABLE Maximum Air Pressure 115 PSI Air Tank Capacity 20 Gallons SPECIFICATIONS TABLE Maximum Air Pressure 115 PSI Air Tank Capacity 20 Gallons Air Flow Capacity 6.2 CFM at 40 PSI 5.2 CFM at 90 PSI Motor 2.5 HP Working / 4 HP Peak 120 Volt / 60 Hz / 13 A / 1-Phase Required

More information

Installation and Operation 370ESP (Electric Single-Point Purger) & 370ESPR (Retrofit Purger)

Installation and Operation 370ESP (Electric Single-Point Purger) & 370ESPR (Retrofit Purger) IB-77 Installation and Operation 370ESP (Electric Single-Point Purger) & 370ESPR (Retrofit Purger) These installation, operation and technical instructions should be used by experienced personnel as a

More information

Electronic Control Pump Instruction Manual

Electronic Control Pump Instruction Manual Limited Warranty Products manufactured by Walrus Pumps Co (Walrus) are warranted to the first user only to be free of defects in material and workmanship for a period of 2 months from date of installation,

More information

This Page Intentionally Left Blank 2

This Page Intentionally Left Blank 2 Reverse Osmosis User s Manual Model R1-1140, R1-2140, R1-3140, R1-4140, R1-5140, R1-6140 R1-6140 Pictured This Page Intentionally Left Blank 2 TABLE OF CONTENTS INTRODUCTION... 4 SAFETY... 4 FEED WATER

More information

CSA Sample Draw Aspirator Adapter Operator s Manual

CSA Sample Draw Aspirator Adapter Operator s Manual 30-0951-CSA Sample Draw Aspirator Adapter Operator s Manual Part Number: 71-0367 Revision: 0 Released: 4/30/15 www.rkiinstruments.com WARNING Read and understand this instruction manual before operating

More information

Accu-Tab PowerBase 3140AT by Axiall Corporation

Accu-Tab PowerBase 3140AT by Axiall Corporation Accu-Tab PowerBase 3140AT by Axiall Corporation Installation and Operating Instructions The PowerBase 3140AT Chlorinator is NSF STD 50 NSF-Listed for pool and spa applications. ONLY Axiall Corp. Accu-Tab

More information

3M Liqui-Cel EXF-14x28 and 14x40 Series Membrane Contactor

3M Liqui-Cel EXF-14x28 and 14x40 Series Membrane Contactor Membrane Contactors 3M Liqui-Cel EXF-14x28 and 14x40 Series Membrane Contactor Assembly and Disassembly Instructions 3M.com/Liqui-Cel TABLE OF CONTENTS I. Safety Information 3 II. Required Materials 4

More information

KJ4000 Operating Instructions & Parts Manual NSN

KJ4000 Operating Instructions & Parts Manual NSN KJ4000 Operating Instructions & Parts Manual NSN 1025-01-473-7710 Mandus Group Ltd. KJ4000 Operators Manual Date: 3 Jan. 2002 TABLE OF CONTENTS General Safety Instructions...Page 1 Operator Instructions...Page

More information

Electronic Control Pump Instruction Manual

Electronic Control Pump Instruction Manual TQ Series Electronic Control Pump Instruction Manual 234867 ISO 9001 Certified Walrus America Inc EC Declaration of Conformity Manufacturer: Walrus Pump Co., Ltd. Address: No. 83-14, Dapiantou, Sanjhih

More information

accidents which arise due to non-observance of these instructions and the safety information herein.

accidents which arise due to non-observance of these instructions and the safety information herein. 3 GALLON PANCAKE COMPRESSOR Model: 50959 CALIFORNIA PROPOSITION 65 WARNING: You can create dust when you cut, sand, drill or grind materials such as wood, paint, metal, concrete, cement, or other masonry.

More information

TOMAR TLC-SERIES (400, 800 & 1200 GPD) REVERSE OSMOSIS TREATMENT SYSTEM OWNER S MANUAL

TOMAR TLC-SERIES (400, 800 & 1200 GPD) REVERSE OSMOSIS TREATMENT SYSTEM OWNER S MANUAL TOMAR TLC-SERIES (400, 800 & 1200 GPD) REVERSE OSMOSIS TREATMENT SYSTEM OWNER S MANUAL Tomar Water Systems Inc. 804 North Twin Oaks Valley Road #118 San Marcos, CA 92069 TLCman-1 07/18 TOMAR TLC R.O. SYSTEM

More information

Model B-1 Pipe Line Strainer 3, 4, 6 & 8 Inch (DN80, DN100, DN150 & DN200) 175 psi (12,1 bar) General Description. Technical Data

Model B-1 Pipe Line Strainer 3, 4, 6 & 8 Inch (DN80, DN100, DN150 & DN200) 175 psi (12,1 bar) General Description. Technical Data Technical Services: Tel: (800) 381-312 / Fax: (800) 71-5500 Customer Service/Sales: Tel: (215) 362-0700 / (800) 523-6512 Fax: (215) 362-5385 Model B-1 Pipe Line Strainer 3,, 6 & 8 Inch (DN80, DN100, DN150

More information

BUBBLER CONTROL SYSTEM

BUBBLER CONTROL SYSTEM BUBBLER CONTROL SYSTEM Description: The HDBCS is a fully automatic bubbler system, which does liquid level measurements in water and wastewater applications. It is a dual air compressor system with, air

More information

Float Operated Level Controllers

Float Operated Level Controllers CONTENTS Float Operated Level Controllers IM0015 Nov. 2014 PAGE Introduction 1 Scope 1 Description 1 Specification 1 Control Installation 2 INTRODUCTION Side Mount Back Mount Prior to installing, the instructions

More information

453 Series Steam Heated Vaporizing Regulator

453 Series Steam Heated Vaporizing Regulator ADI 0453A Certified ISO 9001:2000 453 Series Steam Heated Vaporizing Regulator INSTALLATION AND OPERATION INSTRUCTIONS Before Installing or Operating, Read and Comply with These Instructions Controls Corporation

More information

Gas Countertop Hot Plates

Gas Countertop Hot Plates Gas Countertop Hot Plates This manual contains important information regarding your Patriot unit. Please read the manual thoroughly prior to equipment set-up, operation and maintenance. Failure to comply

More information

GETZ EQUIPMENT INNOVATORS RECOVERY SYSTEM CLEAN AGENT FE-36 / HALOTRON 1 PART NO. 4G59751 OPERATIONS MANUAL

GETZ EQUIPMENT INNOVATORS RECOVERY SYSTEM CLEAN AGENT FE-36 / HALOTRON 1 PART NO. 4G59751 OPERATIONS MANUAL GETZ EQUIPMENT INNOVATORS CLEAN AGENT FE-36 / HALOTRON 1 PART NO. 4G59751 OPERATIONS MANUAL GETZ EQUIPMENT INNOVATORS PEKIN, ILLINOIS, U.S.A. PHONE: (888) 747-4389 FAX: (309) 495-0625 Limited Warranty

More information

FLOW CONTROL & AIR PILOT SWITCH VALVES

FLOW CONTROL & AIR PILOT SWITCH VALVES DESIGNER AND MANUFACTURER OF HYDRAULIC AND PNEUMATIC EQUIPMENT SC HYDRAULIC ENGINEERING CORPORATION FLOW CONTROL & AIR PILOT SWITCH VALVES A High Pressure History An innovator and pioneer in the field

More information

TOMAR TSM-1500 REVERSE OSMOSIS TREATMENT SYSTEM OWNER S MANUAL

TOMAR TSM-1500 REVERSE OSMOSIS TREATMENT SYSTEM OWNER S MANUAL TOMAR TSM-1500 REVERSE OSMOSIS TREATMENT SYSTEM OWNER S MANUAL Tomar Water Systems Inc. 804 North Twin Oaks Valley Road #118 San Marcos, CA 92069 tsm200man 07/06 TOMAR TSM-1500 R.O. SYSTEM TABLE OF CONTENTS

More information

Nitrogen Supply System

Nitrogen Supply System ATMOSCOPE Nitrogen Supply System NS500 Users Guide Copyright 2001 EDSYN, INC. ATMOSCOPE Nitrogen Supply Systems TABLE OF CONTENTS Introduction............................. 3 General Information.......................

More information

User's Manual. Heavy Duty Dissolved Oxygen Meter. Model

User's Manual. Heavy Duty Dissolved Oxygen Meter. Model User's Manual Heavy Duty Dissolved Oxygen Meter Model 407510 Introduction Congratulations on your purchase of Extech's Heavy Duty Dissolved Oxygen / Temperature Meter which simultaneously displays Dissolved

More information

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS 18 GAUGE 1-1/4 INCH BRAD NAILER Model: 7611 CALIFORNIA PROPOSITION 65 WARNING: You can create dust when you cut, sand, drill or grind materials such as wood, paint, metal, concrete, cement, or other masonry.

More information

42045 Heavy Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor Only) Heavy Duty ADA Base Model Kit: 110/145 PSI (ADA Compressor Only)

42045 Heavy Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor Only) Heavy Duty ADA Base Model Kit: 110/145 PSI (ADA Compressor Only) 42045 Heavy Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor Only) 42047 Heavy Duty ADA Base Model Kit: 110/145 PSI (ADA Compressor Only) 45052 Constant Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor

More information

INSTALLATION & MAINTENANCE INSTRUCTIONS

INSTALLATION & MAINTENANCE INSTRUCTIONS DESCRIPTION / IDENTIFICATION The QBX series valve uses Proportion-Air closed loop technology for Pressure control. It gives an output pressure proportional to an electrical command signal input. The QB1X

More information

APCO ASU-SCAV & ASU-CAV SINGLE BODY COMBINATION AIR VALVES

APCO ASU-SCAV & ASU-CAV SINGLE BODY COMBINATION AIR VALVES APCO ASU-SCAV & ASU-CAV SINGLE BODY COMBINATION AIR VALVES Instruction D12039 December 2015 Instructions These instructions provide installation, operation and maintenance information for the. They are

More information

1020 Industrial Drive, Orlinda, TN fax

1020 Industrial Drive, Orlinda, TN fax Operation Manual Tank Distribution System A-UPT Series 615-654-4441 sales@specialtyh2o.com 615-654-4449 fax TABLE OF CONTENTS Section 1 GENERAL 1.2 Warnings and Cautions... 1 1.2 Theory of Operation...

More information

400C & 450C DUAL PERFORMANCE VALUE PACKS

400C & 450C DUAL PERFORMANCE VALUE PACKS (Chrome) PART NO. 40013 (Silver) PART NO. 45012 (Chrome) PART NO. 45013 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual before

More information

Interface Devices, Inc. Hydraulic Mini Mule

Interface Devices, Inc. Hydraulic Mini Mule Interface Devices, Inc. Hydraulic Mini Mule INSTALLATION, OPERATION & MAINTENANCE MANUAL IMPORTANT! FILE THIS MANUAL IN A SAFE PLACE FOR FUTURE SERVICE & PARTS NEEDS ALWAYS REFERENCE THE SERIAL NUMBER

More information