DCS Series 1 kw, 1.2 kw, & 3 kw
|
|
- Annice O’Neal’
- 6 years ago
- Views:
Transcription
1 Established 1981 Advanced Test Equipment Rentals ATEC (2832) DCS Series 1 kw, 1.2 kw, & 3 kw DCS Applications The DCS Family is ideally suited f a wide range of applications requiring DC power in a small fm fact. Applications range from manufacturing test of automotive components, telecommunications products and avionics to beam steering, process control and labaty R&D use. The DCS Family of 1 kw, 1.2 kw and 3 kw programmable power supplies utilize switching-mode technology to achieve high power density in a low profile chassis. Utilizing unique packaging techniques, the DCS Family provides continuous full output power (1 kw, 1.2 kw 3 kw) in any volt/ amp combination within the rated output voltage and current limits. This family has 10-turn potentiometers to adjust voltage and current settings that are displayed simultaneously. LEDs indicate overtemperature,remote programming, shutdown and overvoltage protection, status and constantvoltage/current mode operation. The DCS 3 kw s have push button control of the output via standby mode, OVP reset, remote/ local programming and preview status of voltage, current and OVP setpoints. DC Programmable Switching Supplies Options include an internal EEE- 488/RS 232 interface, isolated analog programming of voltage and current, and the multichannel slave interface (Option M). Key Features Output ranges from 0-8 VDC to VDC; current levels from 1.7A to 350A Power Density 1 kw 1.2 kw of power in a 19 lb. package only 1.75 inches high 3 kw of power in a 33 lb. package only 3.5 inches high nput 1 kw 1.2 kw: VAC, single phase, VAC, single phase Hz 3 kw: VAC, three phase VAC, single phase Hz (2.5 kw max with single phase input Line regulation: 0.1% Load regulation: 0.1% Remote Programming Selectable remote programming f voltage, current and OVP Optional internal EEE-488/ RS 232 nterface Card with voltage and current readback and adjustable OVP (Option M9C) Optional multichannel slave interface (Option M) Optional isolated analog programming (Option M51A) Software LabVEW driver f M9C/M can be downloaded at no cost at Regulaty Compliance CE Mark on all models, FCC Part 15 Class A and CSA 22.2 #220 (1 and 1.2 kw only) 5 Year Warranty
2 Output and 1 kw DCS 8-125E DCS E DCS 20-50E DCS 33-33E DCS 40-25E DCS 50-20E DCS 60-18E DCS 80-13E DCS E DCS 150-7E DCS E DCS E kw DCS 8-140E DCS E DCS 20-60E DCS 33-36E DCS 40-30E DCS 50-24E DCS 60-20E DCS 80-15E DCS E DCS 150-8E DCS 300-4E DCS 600-2E kw DCS 8-350E DCS E DCS E DCS 40-75E DCS 55-55E DCS 60-50E DCS 80-37E DCS E Resolution: 0.02% (mv RMS P-P): See table (Line Load) : 0.1% : 0.1% Transient Response: Typically recovers in 500 µs (1 & 1.2 kw) 1ms (3k W) to 1% of steady-state output voltage (within 1% of Vmax) f % % load change. Stability: ±0.05% of maximum voltage current over 8 hours after 30 minute warm-up time at fixed line, load and temperature Efficiency: See table Temperature Coefficient: 0.02%/ C of maximum output voltage; 0.03%/ C of maximum output current nput and Frequency 1 kw: VAC, single phase, 8A typical, Hz; VAC, single phase, 15A typical, Hz, internal jumper selectable (see M1 option) 1.2 kw: VAC, single phase, 9A typical, Hz; VAC, single phase, 18A typical, Hz, internal jumper selectable (see M1 option) 3 kw: VAC, three phase, 14A typical, Hz; VAC, single phase, 20A typical, Hz Note: Maximum power output of 3 kw supplies must be limited to 2.5 kw f single phase input Soft Start: Line current is lower than full load peak value during turn-on power application after restart General Operating Temperature: 0 C to 50 C (no derating), 50 C to 70 C (derate 2%/ C above 50 C) Stage Temperature: -55 C to C Humidity Range: 0 to 80% RH, non condensing Meter Accuracy: 1% of full scale + 1 count Max. Differential from Output to Safety Ground: 150 VDC Remote Start/Stop and nterlock: TTL compatible input VAC ( VDC) a contact closure Cooling: nternal fan, overtemperature shutdown if internal heat sink exceeeds set temperature Remote Sense: The maximum allowed sense line drop is 4V per line (2V on the DCS 8 and 10V 1kW and 1.2 kw models and 1V/line f all 3 kw models) Remote Programming: External jumper via rear panel connect J3 Overvoltage Protection: Crowbar type adjustable from 5-110% of rated output using front panel control (local remote program selectable via J3 jumper) Remote Analog Programming Linearity: ±1% Accuracy: ±5% Software: LabVEW driver f M9C/M can be downloaded at no cost at Regulaty Compliance: CE Mark (1, 1.2, 3k W); FCC Part 15 Class A, UL1012, CSA 22.2 #220 (1 and 1.2 kw only) Dimensions 1 kw and 1.2 kw: 1U 1.75 (44 mm) H x 19 (4 mm) W x 17.5 (444 mm) D 3 kw: 2U 3.5 (88 mm) H x 19 (4 mm) W x 17.5 (444 mm) D Weight 1 kw and 1.2 kw: 19 lbs. ( 8.6 kg) 3 kw: 33 lbs. (15 kg) Shipping Weight 1 kw and 1.2 kw: 24 lbs. (10.9 kg) 3 kw: 42 lbs. (19 kg) Options & Accessies M1: Facty configured f 115 VAC input (1 kw and 1.2 kw units only) M9C: nternal EEE-488/RS 232 nterface M13: Locking shafts (front panel potentiometers) M32: Master/slave paralleling cable configured f two units M33: Replace input connect with terminal block (3 kw only) M51A: solated analog programming control of V//OVP and isolated V/ monit outputs up to 500V relative to the supply s return line M: Multichannel slave interface allows use of a single GPB address (using 1 master unit with M9C option) to control multiple units via a standard RS4 connect (3 ft. connect included)
3 DCS 1 kw Output Power VDC 50 C Combined Line and Load % Constant Mode* DCS 8-125E mv 60 mv DCS 20-50E mv 60 mv DCS 33-33E mv 60 mv Noise (P-P) Transient Response Time µs (Typ) Temp. Coeff. %/ C (Typ) % Vmax (Typ) DCS E mv 60 mv Programming Constants Mode Ohms/V V/V DCS 40-25E mv 60 mv DCS 50-20E mv 60 mv DCS 60-18E mv 60 mv DCS 80-13E mv 60 mv V = 0-5V = 0-100% V0 DCS E mv 60 mv DCS 150-7E mv 160 mv DCS E mv 200 mv DCS E *** *** *** *** *** *** *** Constant Mode* Line and Load % Combined ma Temp. Coeff. %/ C % 0 Max. Programming Constants, Mode Ohms/A V/A nput, A Nominal 230V Single 208V Three Efficiency % Case DCS 8-125E N/A DCS E N/A DCS 20-50E N/A DCS 33-33E N/A DCS 40-25E N/A DCS 50-20E % 0 8 N/A DCS 60-18E V= 8 N/A % 0 DCS 80-13E N/A 86 DCS E N/A 86 DCS 150-7E N/A 86 DCS E N/A 86 DCS E *** *** *** *** *** *** *** *** *** * Typical resolution is 0.02% ** RMS ripple typical from 20 Hz to 300 khz ***Consult facty
4 DCS 1.2 kw Output Power VDC 50 C Combined Line and Load % Constant Mode* DCS 8-140E mv 60 mv DCS E mv 60 mv DCS 33-36E mv 60 mv Noise (P-P) Transient Response Time µs (Typ) Temp. Coeff. %/ C (Typ) % Vmax (Typ) DCS 20-60E mv 60 mv Programming Constants Mode Ohms/V V/V DCS 40-30E mv 60 mv DCS 50-24E mv 60 mv DCS 60-20E mv 60 mv DCS 80-15E mv 60 mv V= DCS E mv 60 mv DCS 150-8E mv 160 mv DCS 300-4E mv 200 mv DCS 600-2E *** *** *** *** *** *** *** Constant Mode* Line and Load % Combined ma Temp. Coeff. %/ C % 0 Max. Programming Constants, Mode Ohms/A V/A nput, A Nominal 230V Single 208V Three Efficiency % Case DCS 8-140E N/A DCS E N/A DCS 20-60E N/A DCS 33-36E N/A DCS 40-30E N/A DCS 50-24E % 0 9 N/A DCS 60-20E V= 9 N/A 0-100% 0 DCS 80-15E N/A DCS E N/A DCS 150-8E N/A DCS 300-4E N/A DCS 600-2E *** *** *** *** *** *** *** * Typical resolution is 0.02% ** RMS ripple typical from 20 Hz to 300 khz *** Consult facty *** ***
5 DCS 3 kw Output Power VDC 50 C Combined Line and Load % Constant Mode* DCS 8-350E mv 100 mv DCS E mv 100 mv Noise (P-P) Transient Response Time µs (Typ) Temp. Coeff. %/ C (Typ) % Vmax (Typ) Programming Constants Mode Ohms/V V/V DCS E mv 100 mv DCS 40-75E mv 100 mv DCS 55-55E mv 100 mv DCS 60-50E mv 100 mv V= DCS 80-37E mv 100 mv DCS E mv 200 mv Constant Mode* Line and Load % Combined ma Temp. Coeff. %/ C % 0 Max. Programming Constants, Mode Ohms/A V/A nput, A Nominal 230V Single 208V Three Efficiency % Case DCS 8-350E DCS E DCS E DCS 40-75E % DCS 55-55E V= % 0 DCS 60-50E DCS 80-37E DCS E * Typical resolution is 0.02% ** RMS ripple typical from 20 Hz to 300 khz
6 Case 1.10 (28) Case 1.10 (28) (445) (445) 1.00 (25) Top View 1.00 (25) Top View 1.72 (43) (4) Front View 1.25 (32) 3.46 (87) (4) Front View 3.00 (76) (429) (429) Rear View Rear View Dimensions in inches (millimeters) Options & Accessies nput Options M1 Facty configured f 115 VAC input (1 and 1.2 kw only) Remote nterface Options M9C nternal EEE-488/RS 232 interface M13 Locking shafts (front panel potentiometers) M32 Master/slave cable configured f two me units M33 Replace input connect with terminal block (3 kw only) M51A solated analog programming control M Multichannel slave interface Rack slide kit (3 kw only) J3 Program and Sense VAC Remote Shutdown 14 TTL Shutdown 2 Shutdown Return VDC 3 OVP Program 16 1 ma Source (OVP) 4 Remote/Local Status ndicat 17 OVP ndicat 5 Mode Status ndicat 18 Thermal S/DN Status 6 Ground V Monit 7 0-5V Monit 20 Remote Select 8 Control 21 1 ma Source (V) 9 Program nput 22 1 ma Source () 10 Program Unit 23 Remote Select 11 Control 24 Return 12 Return Sense 25 POS Output (8-100V s Only) 13 POS Sense (8-100V s Only) 9250 Brown Deer Road, San Diego Califnia / / Fax: 8/ N EUROPE Kaap Hondreef AT Utrecht The Netherlands Fax: sales@elgar.com Web Site: DCS 10/03
Sorensen DCS Series. 1 3 kw V A. General Purpose Systems Power Supply
Sensen DCS Series General Purpose Systems Power Supply High power density / low ripple and noise High programming resolution with Ethernet interface Constant voltage and current mode Remote sensing Isolated
More informationWatts. xppower.com. Input. General. Environmental. Output. EMC & Safety. Output Voltages from 2.5 V to 48 V. Non-standard Outputs Available
-0 Watts AEH Series s from. V to 8 V xppower.com Non-standard s Available Universal Input Single & Multiple Versions 0 C to +60 C Operating Temperature Efficiency up to 80% Non-standard Connectors Available
More informationSeries AM3T-VZ 3 Watt DC-DC Converter
Click on Series name for product info on aimtec.com Series AM3T-VZ FEATURES: Wide 2:1 Range 24 Pin DIP Package High up to 82% Metal Package Operating Temperature -4 o C to +85 o C / Isolation 15 or 35
More informationFEATURES AND BENEFITS. Meets UL/EN/IEC , 4Th ed. For EMC*
LPS Medical FEATURES AND BENEFITS Meets UL/EN/IEC60601-1-2, 4Th ed. For EMC* Approved To EN/IEC/UL60601-1, 3rd edition With Isolation Levels Which Satisfy The 2 MOPP Requirements Meets DoE Efficiency Level
More informationDimensions [All numbers in brackets are in millimeters.] K4-2 US (supplied) 1/2" Centered (Default)
Proportional damper actuator, non-spring return, Multi-Function Technology Torque min. Control to 0 VDC (DEFULT) Feedback to 0 VDC (DEFULT) For proportional modulation of dampers in HVC systems. The is
More informationRPS900W Redundant Power Supply. Installation Guide.
RPS900W Redundant Power Supply Installation Guide www.edge-core.com Installation Guide RPS900W Redundant Power Supply Single DC Output Port with Dual Output Voltages RPS900W E10013-CS-R01 1500000081A
More informationTEL/jlRE" Introduction. Display Features and Modes. Startup Procedure. Power-Up Procedure. Adjustment Modes
TEL/jlRE" Introduction The Telaire 7001 CO 2 /T emperature monitor (shown in Fi gt u e 1 below) is an easy to use hand-held instnunent, which provides stable and highly accurate readings due to Telaire
More informationPneumatic high-pressure controller Model CPC7000
Calibration technology Pneumatic high-pressure controller Model CPC7000 WIKA data sheet CT 27.63 Applications Automotive and avionics industry Industry (laboratory, workshop and production) Transmitter
More informationFeatures. Main Voltage: Vdc. Input Control Signal: 0-5 Vdc or 4-20 madc (Sourcing) Monitor Output Voltage: 0-5 Vdc or 4-20 madc (Sourcing)
1 X-Flow Mass Flow Controller Flow Range from 0.8 ml/min to 20 l/min Target Markets Laboratory and Process Instrumentation Pharma / Bio-Pharma Equipment Air Quality Monitoring Systems Furnace and Coatings
More informationBUBBLER CONTROL SYSTEM
BUBBLER CONTROL SYSTEM Description: The LDBCS is a fully automatic bubbler system, which does liquid level measurements in water and wastewater applications. It is a dual air compressor system with, air
More informationAdditel 780 Series Pressure Controller
Additel 780 Series Pressure Controller Pressure ranges from vacuum to 3,000 psi (200 bar) Removable interchangeable intelligent sensors Precision accuracy of 0.005% of reading plus 0.005% of full scale
More informationBAROMETER PRESSURE STANDARD PRESSURE CONTROLLER
BAROMETER PRESSURE STANDARD PRESSURE CONTROLLER Features ±0.01% FS Measurement & Control Accuracy ±0.001% /ºC Thermal Stability Pressure Ranges from ±1 psid to 1200 psia Applications Barometric Measurement
More informationBUBBLER CONTROL SYSTEM
BUBBLER CONTROL SYSTEM Description: The HDBCS is a fully automatic bubbler system, which does liquid level measurements in water and wastewater applications. It is a dual air compressor system with, air
More informationPneumatic high-pressure controller Model CPC7000
Calibration technology Pneumatic high-pressure controller Model CPC7000 WIKA data sheet CT 27.63 Applications Healthcare and avionics industry Industry (laboratory, workshop and production) Transmitter
More informationAdditel 780 Series Pressure Controller
Additel 780 Series Pressure Controller Pressure ranges from vacuum to 3,000 psi (200 bar) Removable interchangeable intelligent sensors Precision accuracy of 0.005% of reading plus 0.005% of full scale
More informationCONTENTS TABLE OF MAIDA S HISTORY TERMINOLOGY & GENERAL SPECIFICATIONS. iii. LEAD CODES and TAPE & REEL STANDARD SERIES 1 HC SERIES 17
TABLE OF CONTENTS MAIDA S HISTORY TERMINOLOGY & GENERAL LEAD CODES and TAPE & REEL i ii iii STANDARD SERIES 1 HC SERIES 17 LOW PROFILE SERIES 33 THERMALLY PROTECTED SERIES 39 HIGH ENERGY SERIES LEAD CODES
More information780S Ultra High Purity Series
Smart Ultra High Purity Thermal Gas Mass Flow Meter Features Measures mass flow directly, no seperate temperature or pressure inputs required Field adjustment of critical flow meter settings via on-board
More informationOC Panel High Limit Aquastat Kit, Manual Reset p/n
OC Panel High Limit Aquastat Kit, Manual Reset p/n 233202 Instruction Sheet APPLICATION The OC (Option Control) Panel High Limit Aquastat Kit provides electronic temperature sensing in a UL limit-rated
More informationXMO2. Panametrics Smart Oxygen Analyzer. Applications. Features. bhge.com. An oxygen transmitter for use in:
XMO2 Panametrics Smart Oxygen Analyzer Applications An oxygen transmitter for use in: Inerting/blanketing liquid storage tanks Reactor feed gases Centrifuge gases Catalyst regeneration Solvent recovery
More informationAutocalibration Systems For In Situ Oxygen Analyzers
Product Data Sheet PDS 106-340AC SPS 4000, IMPS 4000, and MPS 3000 January, 1999 Autocalibration Systems For In Situ Oxygen Analyzers Cost-effective autocalibration systems for installations ranging from
More informationVerdi G-Series. High-Power Pumps for Ti:Sapphire Lasers and Amplifiers FEATURES
Verdi G-Series High-Power Pumps for Ti:Sapphire Lasers and Amplifiers The Verdi G is a high performance CW laser providing up to 20W at 532 nm, ideal for pumping Ti:Sapphire lasers and amplifiers, for
More informationSonoMeter 30 Energy Meters
Data Sheet SonoMeter 30 Energy Meters Description The Danfoss SonoMeter 30 is a range of ultrasonic, compact energy meters intended for measuring energy consumption in heating and cooling applications
More informationInstruction Manual BA90 Precision Barometer
Instruction Manual BA90 Precision Barometer halstrup-walcher GmbH Stegener Straße 10 D-79199 Kirchzarten Germany Phone: +49 (0) 76 61/39 63 0 Fax: +49 (0) 76 61/39 63 99 E-Mail: info@halstrup-walcher.com
More informationP9000 DESCRIPTION. For parts requiring RoHS compliance, please contact factory. P February /6
P9000 High accuracy through digital compensation High thermal stability Rugged stainless steel construction Ideal for test stands High burst pressure limit DESCRIPTION The P9000 Series is a range of advanced,
More informationSimple Set. Pressure Independent Control Valves 2 Way 1/2-2
The Bray Simple Set is a threaded pressure independent control (PIC) valve designed for a wide variety of hot water and chilled water control applications. The SS Series combines high rangeability control
More informationC-Flow Coriolis Mass Flow Meters
Coriolis Mass Flow Meters Ready for Take Off The New Compact C-Flow Küppers Elektromechanik GmbH The C-Flow The C-Flow Coriolis Mass Meters consist of two components: KCE Transmitter KCM Transducer 2 KEM
More informationMass Flow Meter (MFM) for gases
Mass Flow Meter (MFM) for gases Type can be combined with Inline MFM for nominal flow rates from 25 l N /min to 1,500 l N /min; 1/4 to 3/4 High accuracy Fast settling time Fieldbus option Special version
More informationAdditel 761 Automated Pressure Calibrators Selection Guide
Automated Calibrators Selection Guide Model Features Range 761-LLP 761-D 761-L 761-LA 761-M 761-MA 761-H 761-HA 761-BP 0.05 to 8 bar.a -0.90 to 25 bar (1.2 to 115 psi.a) (-13 to 375 psi) 0.1 to 26 bar.a
More information7250 Sys. Ruska Multi-Range Pressure Calibration System. GE Sensing & Inspection Technologies. Features. Applications
GE Sensing & Inspection Technologies 7250 Sys Ruska Multi-Range Pressure Calibration System Features Fully integrated multi-range pressure test and calibration systems Select either an eight range or the
More informationHUMOR 20 HUMOR 20. High-precision Humidity Calibrator. Water T, p1
High-precision Humidity Calibrator The role of humidity calibrations that are accurate, reproducible, and documentable is becoming more and more important. ISO quality guidelines and regulations according
More informationGenesis MX SLM-Series
Single Frequency Visible OEM and End-User OPS Laser Systems Applications like Flow Cytometry, Particle Counting, DNA Sequencing and Microscopy are enable by low noise, visible true CW lasers. The Genesis
More informationCertified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters
www.kem-kueppers.com info@kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters Description The Tricor Mass Flow Meters measure simultaneously mass
More informationAMS 6915 Board mount pressure sensor with digital output (I²C)
Board mount pressure sensor with digital output (I²C) FEATURES Calibrated and temperature compensated pressure sensor with digital output (I²C) Differential, relative (gage), bidirectional differential,
More informationAR740 RPS Redundant Power Supply Quick Install Guide
AR740 RPS Redundant Power Supply Quick Install Guide AT-RPS 740 Quick Install Guide Document Number. 1999-2006 Allied Telesis Inc. All rights reserved. No part of this publication may be reproduced without
More informationAdditel 761 Automated Pressure Calibrators
Automated Calibrators UPDATED Fully automated pressure calibrator with built-in pressure generator / controller to as high as 600 psi (40 bar) or as low as 0.01 Pa (0.00004 inh 2 O) accuracy Dual pressure
More informationPPC4E Pressure Controller/Calibrator Superior rangeability and reliability
PPC4E Pressure Controller/Calibrator Superior rangeability and reliability Technical Data ± 0.02 % of AutoRanged spans from ± 1 kpa (0.15 psi) to 14 MPa (2,000 psi) The Fluke Calibration PPC4E brings high
More informationZ, Y, and X PURGE INDICATORS / CONTROLLERS
PurgEx XXXXXX Z, Y, and X PURGE INDICATORS / CONTROLLERS PURGE / PRESSURIZATION PURGE / PRESSURIZATION XXXXX XXXXXXXXX 8626 SERIES Globally Certified Z,Y,X Purge Indicators / Controllers and Accessories
More informationAdditel 761 Automated Pressure Calibrators Selection Guide
/ Process Calibration Equipment Automated Calibrators Selection Guide Model Features Range Module 1 761-LLP 761-D 761-L 761-LA 761-M 761-MA 761-H 761-HA 761-BP -2.5 to 2.5 mbar (-1 to 1 inh 2 O) -0.95
More informationThe HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.
The HumiSys RH Generator Designed, built, and supported by InstruQuest Inc. Versatile Relative Humidity Generation and Multi-Sensor System The new HumiSys with single or dual RH probes capabilities is
More informationSPECIFICATIONS ATTENTION
VPS 504 S06 Installation Manual - P/N 80122 - Ed. 01/09 VPS 504 S06 and S05 Valve Proving System Installation Instructions VPS 1 6 Gases Natural gas, air and other inert gases. NOT suitable for butane
More informationINSTRUCTION MANUAL. FLOW CONTROL DRAWERS MANUAL / PLC CONTROL SERIES Model Version Perma Pure LLC Tel:
PERMA PURE INSTRUCTION MANUAL FLOW CONTROL DRAWERS MANUAL / PLC CONTROL SERIES Model 3300 Version 4.06 Perma Pure LLC Tel: 732-244-0010 P.O. Box 2105, 8 Executive Drive Tel: 800-337-3762 (toll free US)
More informationTH-1800-T TRX-700-CNG Converter
TH-1800-T TRX-700-CNG Converter low detector The CNG fuel gas flowmeter is so accurate as to meet a demand of measuring the CNG directly by making the most use of our well-established mini-thermal flowmeter
More informationCORI-FLOW PRECISION MASS FLOW METER / CONTROLLER FOR LIQUIDS AND GASES
SENSORS FOR MASS FLOW AND PRESSURE CORI-FLOW PRECISION MASS FLOW METER / CONTROLLER FOR LIQUIDS AND GASES INTRODUCTION Bronkhorst High-Tech BV is the worldwide pioneer in the field of low flow liquid metering
More informationcombustion efficiency monitoring General Purpose Applications Flue gas oxygen analyzers Combustion & Environmental Monitoring An Company
combustion efficiency monitoring Flue gas oxygen analyzers General Purpose Applications Combustion & Environmental Monitoring An Company Flue Gas Oxygen Genesis is a range of flue gas analyzers for measuring
More informationOEM Manual MODEL 2305 ECONOMICAL DIGITAL SINGLE CYLINDER SCALE
OEM Manual MODEL 2305 ECONOMICAL DIGITAL SINGLE CYLINDER SCALE 1 These instructions generally describe the installation, operation, and maintenance of subject equipment. The manufacturer reserves the right
More informationAIR FLOW CALIBRATORS Single Sensor Designs
F&J SPECIALTY PRODUCTS, INC. The Nucleus of Quality Air Monitoring Programs AIR FLOW CALIBRATORS Single Sensor Designs 100 240 VAC World Calibrator PC Version World Calibrator VFD Version Compact Digital
More informationT EK-COR 1100A Coriolis Mass Flowmeter
T EK-COR 1100A Coriolis Mass Flowmeter Instruction Manual Document Number: IM-1100A NOTICE Read this manual before working with the product. For personal and system safety, and for optimum product performance,
More informationSVEA II GSM Connector User Manual
www.possio.com SVEA II GSM Connector User Manual 1. Introduction Before using SVEA II please read this manual carefully and keep it for future reference. SVEA II GSM Connector is a device for realization
More informationcombustion efficiency monitoring Flue gas oxygen analyzers General Purpose Applications Combustion & Environmental Monitoring
combustion efficiency monitoring Flue gas oxygen analyzers General Purpose Applications Combustion & Environmental Monitoring Flue Gas Oxygen Genesis is a range of flue gas analyzers for measuring Oxygen
More informationSECTION 2 SMART PAYOUT MANUAL SET FIELD SERVICE MANUAL
SECTION 2 SMART PAYOUT MANUAL SET FIELD SERVICE MANUAL Innovative Technology assume no responsibility for errors, omissions, or damages resulting from the use of information contained within this manual.
More informationAdditel 761 Automated Pressure Calibrators
Additel 761 Fully automated pressure calibrator with built-in pressure generator / controller to as high as 600 psi (40 bar) or as low as 0.01 Pa (0.00004 inh 2 O) accuracy Dual pressure modules Built-in
More informationCMA4000 Specifications
CMA4000 Specifications Display Mass Storage VGA LCD Display (8.4 color or 8.2 monochrome) Up to 125 traces internal storage. Over 65,000 traces with optional hard drive. Up to 180 traces for a standard
More informationAnalogue and Digital Mass Flow Meters and Controllers for Gases MASS-STREAM
Analogue and Digital Mass Flow Meters and Controllers for Gases MASS-STREAM M+W Instruments Your partner Key Facts M+W Instruments was founded in 1988 and has always specialised in thermal mass flow meters
More informationPlasma. Argon Production Helium Liquefaction Truck Loading Pure Gas Bottling
SERVOPRO Plasma The SERVOPRO Plasma is a Plasma Emission Detector based analyser designed to continuously measure Nitrogen in pure Argon for process and quality control in Argon production within Cryogenic
More informationTABLE OF CONTENTS 2 TALAS DRYER 4 TALAS MEASURER 7 TALAS PORTABLE DRYER 9 TALAS LEAKER 11 TALAS STARTER 14 TALAS AUXILIARY 17 APPENDICES
TABLE OF CONTENTS 2 TALAS DRYER 4 TALAS MEASURER 7 TALAS PORTABLE DRYER 9 TALAS LEAKER 11 TALAS STARTER 14 TALAS AUXILIARY 17 APPENDICES ALL PICTURES SHOWN ARE FOR REFERENCE ONLY ACTUAL PRODUCT MAY VARY
More informationHUMOR 20. High-precision Humidity Calibrator HUMOR 20. Operation
High-precision Humidity Calibrator The role of humidity calibrations that are accurate, reproducible, and documentable is becoming more and more important. ISO quality guidelines and regulations according
More informationAdditel 761 Automated Pressure Calibrators
Automated Calibrators UPDATED Fully automated pressure calibrator with built-in pressure generator / controller to as high as 600 psi (40 bar) or as low as 0.01 Pa (0.00004 inh 2 O) accuracy Dual pressure
More informationAdditel 780 Series Pressure Controller
Additel 780 Series Pressure Controller Pressure / Process Calibration Equipment Pressure ranges from vacuum to 3,000 psi (200 bar) Removable interchangeable intelligent sensors Precision accuracy of 0.005%
More informationBETTER SAMPLE CARE. Spark Holland introduces. SPH1299 UHPLC Gradient Pump
BETTER SAMPLE CARE Spark Holland introduces SPH1299 UHPLC Gradient Pump SPH1299 Spark Holland introduces SPH1299 UHPLC Gradient Pump Robust, Precise and Easy to use Innovative pumping technology created
More informationFeatures. Description
Features Fast response flow meter ideal for inert gas and liquid mass flow measurement applications Smart electronics permit field adjustment of critical flow meter settings Field validation of flow meter
More informationOverview. Front Panel: Keypad and Display
Overview The GA-200B is an analyzer that integrates a gas sampling system with sensors to measure and display the concentrations of oxygen and carbon dioxide in a sample as the percentage of a gas in the
More informationAutoChanger Installation & User Guide Issue 2
1 INDEX Page 1. Introduction... 3 2. AutoChanger Components Guide 4 3. Installation. 5-11 a) Installation Guidelines.. 5 b) Installation Retrofit... 6-11 c) Installation New... 11 4. AutoChanger User Guide
More informationMiniature controls. Contactors. Overload relays. Starters. Control relays
Contactors Overload relays Starters Control relays Description General features Wiring terminations available include plugon connectors, wire pins for PC board mounting and solder connections Low power
More informationProduct Overview. Product Description CHAPTER
CHAPTER 1 This chapter provides a functional overview of the Cisco Redundant Power System 2300 and covers these topics: Product Description, page 1-1 Features, page 1-3 Supported Devices, page 1-4 Deployment
More informationVerdi G-Series Family
Verdi G-Series Family High-Power Pumps for Ti:Sapphire Lasers and Amplifiers Applications such as ultrafast spectroscopy, multiphoton microscopy, terahertz imaging, and Optical Coherence Tomography (OCT)
More informationHI 2314 HI 2315 HI 23151
Instruction Manual HI 2314 HI 2315 HI 23151 Multi-Range Conductivity Meters for Laboratories www.hannainst.com Dear Customer, Thank you for choosing a Hanna Instruments product. Please read this instruction
More informationSimple Set Max. Pressure Independent Control Valves 2 Way 2-1/ /09/18
The Bray Simple Set Max is a flanged pressure independent control (PIC) valve designed for a wide variety of hot water and chilled water control applications. The SSM Series combines high rangeability
More informationAPPLICATION NOTE. OJ-DV Modbus protocol. OJ Drives A DRIVES PROGRAMME DEDICATED TO VENTILATION SOLUTIONS E 03/18 (PDJ) 2018 OJ Electronics A/S
APPLICATION NOTE 67467E 03/18 (PDJ) 2018 OJ Electronics A/S OJ-DV Modbus protocol OJ Drives A DRIVES PROGRAMME DEDICATED TO VENTILATION SOLUTIONS Introduction This protocol contains the Modbus addresses
More informationEPP4 Pressure Regulator Basic G 1/4"
EPP4 Pressure Regulator Basic G 1/4" Flow Curve 1/4" Dimensions Outlet pressure - bar 9 8 7 6 5 4 3 2 1 0 0 20 40 60 70 80 100 120 Flow rate - Nm 3 /h The male connector adopted on the EPP4 is a standard
More informationDesign Features. General Description
Model thermal Mass Flow Controllers are designed to indicate and control set flow rates of gases. The combines the characteristics and accuracy of conventional mass flow devices into a unique compact design
More informationRaising the bar. Philips Advance Optanium high efficiency instant start T8 ballasts have set new standards for maximizing energy savings
Raising the bar Philips Advance Optanium high efficiency instant start T8 ballasts have set new standards for maximizing energy savings Philips Advance Optanium high-efficiency electronic ballasts are
More informationAutocalibration Systems for In Situ Oxygen Analyzers
Product Data Sheet PDS 106-340AC.A01 February, 2006 SPS 4001B, IMPS 4000 and MPS 3000 Autocalibration Systems for In Situ Oxygen Analyzers Cost-effective autocalibration systems for installations ranging
More informationFor Multi-Parameter Meters see mvx
Design Features VORTEX IN-LINE FLOW METERS For Multi-Parameter Meters see m Principles of Operation n No moving parts to wear or fail. n Electronics can be remotely mounted up to 30.5 m (0 ft). n No fluid
More informationQuarterly Inspection Report
Quarterly Inspection Report System Status: Normal Customer Customer Address City State, Zip Contact Phone Site Customer Address City State, Zip Contact Phone Project Number 123456.7890 Inspection Type
More informationRimage Everest 600 Thermal Retransfer Printer
Rimage Everest 600 Thermal Retransfer Printer Superior Print Technology: Superior Results CONTENTS I. Overview II. Printer Comparison III. Print Modes IV. Advantages of Thermal Retransfer Printing V. Printer
More informationHUMOR 20. High Accuracy Humidity Calibrator. Water T, p1 HUMOR 20 V1.0
High Accuracy Humidity Calibrator The role of humidity calibrations that are accurate, reproducible, and documentable is becoming more and more important. ISO quality guidelines and regulations according
More informationEC214 EC215 - EC215R Bench Conductivity Meters
Instruction Manual EC214 EC215 - EC215R Bench Conductivity Meters http://www.hannainst.com These Instruments are in Compliance with the CE Directives Dear Customer, Thank you for choosing a Hanna Instruments
More informationColumbus Instruments
0215-003M Portable O 2 /CO 2 /CH 4 Meter User s Manual Columbus Instruments 950 NORTH HAGUE AVENUE TEL:(614) 276-0861 COLUMBUS, OHIO 43204, USA FAX:(614) 276-0529 1 www.colinst.com TOLL FREE 1-800-669-5011
More informationDF-550E PROCESS ANALYSERS APPLICATIONS FEATURES
PROCESS ANALYSERS DF-550E The DF-550E Nano Trace oxygen analyser is a Coulometric sensor based analyser designed to measure oxygen as a contaminant at ultra trace levels in ultra high purity electronic
More informationFor Multi-Parameter Meters see mvx
VORTEX IN-LINE FLOW METERS Design Features For Multi-Parameter Meters see mvx Principles of Operation VX No moving parts to wear or fail. Electronics can be remotely mounted up to 30.5 m (0 ft). No fluid
More informationTechnical Instructions Document No. CA2N4721E-P25 Rev. 1, February, Modulating Control Valve for Hot Gas Control.
Document No. CAN7E-P MFB LX Series Modulating Control Valve Description Valves with magnetic actuator for modulating capacity control of refrigeration units and for heat recovery. Features Quick positioning
More informationIntelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter
Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter Overview C % ppm 4~20mA Analog Output ppb Power Supply 100~240 VAC mg/l Dimensions 96 x 96 x 132mm RS-485 Digital Output (for DC-5310-RS only)
More informationAutomatic Valve Proving Control
ISO 9001 Automatic Valve Proving Control 7 696 LDU11 UL recognized FM approved Features Performs leak test of the gas shut-off valves before start-up and/or immediately after burner shut-down No inlet
More informationOptical Time Domain Reflectometer. Operating System 2 Windows XPe Windows XP Pro with desktop option 256 MB
CMA 4500 Series Optical Time Domain Reflectometer The CMA 4500 continues NetTest s tradition as the industry s premier OTDR solution designed with the high performance and scalability necessary to meet
More informationGas density monitor With integrated transmitter Model GDM-100-TI
SF 6 gas solutions Gas density monitor With integrated transmitter Model GDM-100-TI grid Products WIKA data sheet SP 60.05 for further approvals see page 5 Applications Gas density monitoring of closed
More informationDEEPSEA. SeaLite Lumos POWER & LIGHT. Operator s Manual Ruffin Road San Diego, CA USA.
SeaLite Lumos DEEPSEA POWER & LIGHT T: (858) 576-1261 F: (858) 576-0219 4033 Ruffin Road San Diego, CA 92123-1817 USA www.deepsea.com sales@deepsea.com REV 08/27/18 Optical Specifications Specification
More informationDigital electro-pneumatic regulators Series ER100
CATALOGUE > Release 8.2 Digital electro-pneumatic regulators Series ER100 TREATMENT > Digital electro-pneumatic regulators Series ER100 Port G1/4» Compact design» Digital display» Analog and digital input»
More informationInstallation and Operation Manual
Manual Static pressure transducer with controller Differential static pressure transducer with analog output and optional PI control mode Large diaphragm element with differential transformer Transducer
More informationWorkhorse-15 Oxygen Generator
11436 Sorrento Valley Road, San Diego CA 92121 USA 858-558-0202 Fax 858-558-1915 Workhorse-15 Oxygen Generator Model No. 5719, 5727, 5735 for Domestic and International Units Part number 1432 Revision
More informationABB MEASUREMENT & ANALYTICS DATA SHEET. WaterMaster FEW530 Electromagnetic water meter
ABB MEASUREMENT & ANALYTICS DATA SHEET WaterMaster FEW530 Electromagnetic water meter 2 WATE RMASTE R F E W 530 ELECT ROMAGNE TIC WATE R ME TE R DS/FE W530/FE T3 -E N RE V. A Measurement made easy Cost
More informationwww.ricelake.com/condec 888-295-8475 UPC5000 PRESSURE CALIBRATION STANDARD Designed for calibrating transmitters, transducers, gauges and other pressure sensitive devices onsite, the portable UPC5000 is
More informationSAPCON. User Manual. Capacitance Continuous Level Indicator. . Introduction. . General Description. . Principle of Operation. .
User Manual Capacitance Continuous Level Indicator Comprehensive User s Manual. Introduction. General Description. Principle of Operation. Specifications. Connection Diagrams. Quick Calibration Chart.
More informationStand-Alone Bubble Detection System
Instruction Sheet P/N Stand-Alone Bubble Detection System 1. Introduction The Bubble Detection system is designed to detect air-bubble induced gaps in a bead of material as it is being dispensed. When
More informationDigital Flow Switch. Series PFM7
Compatible with rgon (r), Carbon Dioxide (CO) and the Mixed Gas (r+co) Digital Flow witch eries PFM7 Flow adjustment valve Fluid r, CO r + CO RoH -color display ee abnormal values at a glance. llows flow
More informationCCT-7320/ROC-2313 Reverse Osmosis Controller
CCT-7320/ROC-2313 Reverse Osmosis Controller 1 General The instrument is a combined control instrument of a reverse osmosis controller and an on-line conductivity instrument. It can perform the operation
More informationMeasuring range Δp (span = 100%) Pa
4.4/ RLE 5: Volume-flow controller, continuous How energy efficiency is improved Enables demand-led volume flow control for the optimisation of energy consumption in ventilation systems. Areas of application
More information5KP-HR Series. TVS Diodes Axial Leaded 5 kw > 5KP-HR series. Description. Uni-directional
5KP-HR Series RoHS Pb e3 AGENCY Uni-directional Agency Approvals AGENCY FILE NUMBER E2353 Bi-directional Maximum Ratings and Thermal Characteristics (T A =25 O C unless otherwise noted) Parameter Symbol
More informationASIC-Based Small Bore Submersible Level Transducer
ASIC-Based Small Bore Submersible Level Transducer KPSI Transducers Series 340 FEATURES Custom Level Ranges up to 230 ft (70 m) H 2 O Unparalleled Performance - Static Accuracy: ±0.05% FS - Total Error
More informationCP3R Quick Start Manual
RUN MON PRM PU EXT NET RUN D700 3 200V RUN MON PRM PU EXT NET RUN D700 3 200V CP3R Quick Start Manual for Constant Pressure Applications This CP3R Drive has been factory pre-programmed for your specific
More information