ULTRAMAT 6 NDIR Gas Analyzers, Singlechannel or Dual-channel Versions

Size: px
Start display at page:

Download "ULTRAMAT 6 NDIR Gas Analyzers, Singlechannel or Dual-channel Versions"

Transcription

1 NDIR Gas Analyzers, Singlechannel or Dual-channel Versions 2 General 2 Application 3 Design Mode of operation 5 Versions 6 Communication 8 unit 8 Connections, assembly Gas paths 0 Electrical connection 2 Technical data 3 Dimensions Ordering data 22 Ordering data, additional versions for TÜV units 23 Field unit 23 Connections, assembly 2 Gas paths 25 Electrical connection 27 Technical data 28 Dimensions 2 Ordering data 3 Ordering data, additional versions for TÜV units 35 Explosion-proof design 37 BARTEC EEx p control unit 0 Ex purging unit MiniPurge FM Spare parts Documentation 2 Conditions of sale and delivery Export regulations 2 Contact addresses Siemens Extract PA 0 November 2002

2 General Application The single-channel or dual-channel gas analyzers operate according to the NDIR two-beam alternating light principle and measure gases highly selectively whose absorption bands lie in the infrared wavelength range from 2 to µm, such as CO, CO 2, NO, SO 2, NH 3, H 2 O, CH and other hydrocarbons. Single-channel analyzers measure up to 2 gas components. Dual-channel analyzers measure up to gas components simultaneously ( components as special application). Special applications Besides the standard combinations special applications concerning material of the gas path, material of sample cell and sample components are also available on request. Special materials of the sample cell 36SS/titanium on request. -component analyzers are also available as special application. Application examples Measurements for boiler control in combustion plants Measurements in safety-relevant areas Measurement of pollutant for emission monitoring according to TA-Luft, 3. and 7. BlmSchV Measurements in the automotive industry (test benches) Warning equipment Emission measurements in incineration plants Process gas concentrations in chemical plants Trace measurements in pure gas processes for quality monitoring Version to analyze flammable and non-flammable gases or vapors for use in hazardous areas (zone and zone 2). (Use in hazardous areas of zone 0 is not permissible.) Special characteristics Four freely-programmable measuring ranges Measuring ranges with suppressed zero possible Measuring range identification One electrically isolated signal output 0/2/ to 20 ma per component Autoranging or manual range switching possible; remote switching is also possible Differential measuring ranges with flow-type reference cell Storage of measured values possible during calibration Time constants selectable within wide limits (static/dynamic noise suppression); i.e. the response time of the analyzer or the component can be matched to the respective application. Simple handling using menu-based operation Fast response time Low long-term drift Measuring-point selection for up to 6 measuring points (programmable) Measuring point identification Two-stage access code to prevent unintentional and unauthorized inputs Internal pressure sensor for correction of variations in atmospheric pressure in the range 600 to 200 hpa absolute External pressure sensor can be connected for correction of variations in the process gas pressure in the range 600 to 500 hpa absolute Automatic range calibration can be parameterized Operation based on NAMUR Recommendation Monitoring of sample gas (flow and pressure) Customer-specific analyzer options such as e.g.: - Customer acceptance - Tag labels - Drift recording Sample cell for use in presence of highly corrosive sample gases. Additional characteristics, dual-channel version Separate design of physical unit, electronics, inputs/outputs and power supply for each channel Display and operation via common LCD panel and keyboard Channels and 2 can be converted to connection in series (linking of gas connections from channel to channel 2 on rear). :Special characteristics of unit unit with HU for installation - in swing frame - in cabinets, with or without slide rails Front panel for service can be hinged down (laptop connection) Internal gas paths: hose made of Viton or pipe made of titanium Gas connections for sample gas input and output: pipe diameter 6 mm or /" Flowmeter for sample gas on front plate (option). Special characteristics of field unit Two-door housing with gas-tight separation of analyzer and electronics sections Each half of the enclosure can be purged separately Parts wetted by the sample gas can be heated up to 65 C (option) Gas path: hose made of Viton or pipe made of titanium Gas connections for sample gas input and output: pipe gland for pipe diameter 6 mm or /" Purging gas connections: pipe diameter 0 mm or 3/8" Simple analyzer exchange since electric connections are easy to remove. 2 Siemens Catalog Extract PA 0 November 2002

3 General Design Display and control panel Large LCD panel for simultaneous display of: - Measured value (digital and analog displays) - Status line - Measuring ranges Contrast of LCD panel adjustable using menu Permanent LED backlighting Washable membrane keyboard with five softkeys Menu-based operation for configuration, test functions, calibration User help in plain text Graphic display of concentration trend; programmable time intervals Operating software in two languages: German/English, English/Spanish, French/English, Spanish/English, Italian/English. Inputs and outputs One analog output per measured component Two analog inputs programmable (e.g. for correction of cross interferences and for external pressure sensor) Six binary inputs freely configurable (e.g. for range switching, external signal processing from sample preparation) Six relay outputs freely configurable e.g. for failure, maintenance request, limit alarm, external solenoid valves Optional with eight additional binary inputs and eight additional relay outputs for automatic calibration with up to four calibration gases Communication RS 85 present in basic unit (connection at the rear; with unit also possibility of connection behind the front plate) Options AK interface for the automotive industry with extended functions Converter to RS 232 Converter to TCP/IP Ethernet Linking to networks via PROFIBUS-DP/-PA interface SIPROM GA software as service and maintenance tool. LED backlit graphic display and membrane keyboard with noticeable click Display of concentrations as numbers and bargraph for channel Status line for display of analyzer status (programmable) Two code levels according to NAMUR (maintenance and specialist level) Easy operation with menu control using five softkeys Display of concentrations as numbers and bargraph for channel 2 Display of start-of-scale and full-scale values Keyboard to enter values Display of current measuring ranges Status line for channel 2 to display the unit status (programmable) ESC key to abort inputs INFO key for help in plain text CLEAR key to delete digital inputs MEAS key to return to measurement mode ENTER key to accept input values Fig., membrane keyboard and graphic display Siemens Catalog Extract PA 0 November

4 General Mode of operation The gas analyzer operates according to the infrared two-beam alternating light principle with double-layer detector and optical coupler. The measuring principle is based on the molecule-specific absorption of bands of infrared radiation. The absorbed wavelengths are characteristic to the individual gases, but may partially overlap. This results in cross-sensitivities which are reduced to a minimum in the gas analyzers by the following measures: Gas-filled filter cell (beam divider) Double-layer detector with optical coupler Optical filters if necessary. Fig. 2 shows the measuring principle. An IR source () which is heated to approx. 700 ºC and which can be shifted to balance the system is divided by the beam divider (3) into two equal beams (sample and reference beams). The beam divider also acts as a filter cell. The reference beam passes through a reference cell (8) filled with N 2 (a non-infrared-active gas) and reaches the right-hand side of the detector () practically unattenuated. The sample beam passes through the sample cell (7) through which the sample gas flows and reaches the left-hand side of the detector (0) attenuated to a lesser or greater extent depending on the concentration of the sample gas. The detector is filled with a defined concentration of the gas component to be measured. The detector is designed as a double-layer detector. The center of the absorption band is preferentially absorbed in the upper detector layer, the edges of the band are absorbed to approximately the same extent in the upper and lower layers. The upper and lower detector layers are connected together via the microflow sensor (2). This coupling means that the spectral sensitivity has a very narrow band. The optical coupler (3) lengthens the lower receiver cell layer optically. The infrared absorption in the second detector layer is varied by changing the slider position (). It is thus possible to individually minimize the influence of interfering components. A chopper (5) rotates between the beam divider and the sample cell and interrupts the two beams alternately and periodically. If absorption takes place in the sample cell, a pulsating flow is generated between the two detector levels which is converted by the microflow sensor (2) into an electric signal. The microflow sensor consists of two nickel grids heated to approx. 20 C which, together with two further resistors, form a Wheatstone bridge. The pulsating flow together with the very close arrangement of the Ni grids leads to a change in resistance. This leads to an offset in the bridge which is dependent on the concentration of the sample gas. Note The sample gases have to enter the analyzer dustfree. Avoid condensate in the sample cells. Therefore an appropriate gas preparation is required in the most applications. The ambient air of the analyzer should be, in a large extent, free of high concentration of the component to be measured IR source, adjustable 2 Optical filter 3 Beam divider (gas filter) Eddy current drive 5 Chopper 6 Sample gas inlet 7 Sample cell Fig. 2, mode of operation 8 Reference cell Sample gas outlet 0 Detector, left Detector, right 2 Microflow sensor 3 Optical coupler Slider, adjustable Siemens Catalog Extract PA 0 November 2002

5 Standard General Versions Gas path unit Field unit Explosion-protected field unit with hoses with pipes Nipple Hose Hose coupling Sample cell: Body Cell lining Stub analyzer cell Window Nipple Pipe Sample cell: Body Cell lining Window Titanium Viton Polyamide 6 Aluminium Aluminium Titanium, O-ring: Viton or Kalrez CaF 2, adhesive: E353, O-ring: Viton or Kalrez Titanium Titanium, O-ring: Viton or Kalrez Aluminium Tantalum CaF 2, adhesive: E353, O-ring: Viton or Kalrez Special applications (examples) Gas path unit Field unit Explosion-protected field unit with pipes with pipes Further versions on request Options Nipple Pipe Sample cell: Body Cell lining Window Nipple Pipe Sample cell: Body Cell lining Window Titan Titanium, O-ring: Viton or Kalrez Titanium Tantalum CaF 2, without adhesive O-ring: Viton or Kalrez SS, type No..57 (36SS).57, O-ring: Viton or Kalrez SS, type No..57 Tantalum CaF 2, without adhesive O-ring: Viton or Kalrez Gas path unit Field unit Explosion-protected field unit Flowmeter Pressure switch Metering pipe Float Float limit Elbows Diaphragm Enclosure Duran glass Duran glass PTFE (Teflon) Viton Viton PA 6.3T Siemens Catalog Extract PA 0 November

6 General Communication Communication Interface parameters The gas analyzers of series 6,, Level RS 85 ULTRAMAT/OXYMAT 6, OXYMAT 6, OXYMAT 6 and Baud rate 600 CALOMAT 6, as well as the ULTRAMAT 23 offer the following communications facilities: Serial RS 85 interface present as standard with internal communications bus (ELAN) which permits communication between the analyzers and with multi-channel analyzers from one channel to the other via the serial interface even without a PC for e.g. information on the process gas pressure and compensation Data bits Stop bit Start bit Parity No echo mode 8 None of the influences of interfering gases. SIPROM GA, a software tool especially for servicing and maintenance tasks. All functions of the analyzers, whether an indi- Ordering information Order No. vidual device or where several are networked together, can be remote controlled and monitored using SIPROM GA. Interface description (German) RS 85/RS 232 converter A5E C75-Z58-U PROFIBUS-DP/-PA is the leading field bus on the market. All RS 85/Ethernet converter C75-A336-D6 Siemens gas analyzers are suitable for PROFIBUS when equipped with an optional plug-in card (retrofitting also possible) SIMATIC cable/bus cable 6XV 830-0EH0 and satisfy the binding "Device profile for analyzers" de- SIMATIC bus connector 6ES7 72-0BB-0XA0 fined by the PNO (PROFIBUS user organization). Central access to the analyzers in the system is possible using the -pin DSUB plug 6ES7 72-0BB-0XA0 SIMATIC PDM operator input software. Repeater 6ES7 72-0AA0-0XA0 (see also Catalog CA 0 or IK PI) 8 7 RS232 RS85 Converter RS232 RS RS232 RS85 Converter RS232 RS SIPROM GA Application: communications software for remote maintenance and servicing of Siemens process gas analyzers; max. 2 analyzers with up to components each. Networking of several gateways is possible when using the RS 85/Ethernet converter. The number of operatable analyzers is increased correspondingly. Functions: display and saving of all analyzer data, remote operation of all analyzer functions, parameter and configuration settings; comprehensive diagnostics information, remote calibration; online help; cyclic saving of measured values and status on hard disk and exporting to commercially available application programs, downloading of new software. Hardware requirements: PC/laptop; recommended with Pentium II 6 MB RAM, free COM port: RS 232 or RS 85, CD drive. Software requirements: Windows 5 or NT ( SP6), Windows 2000 or Windows X-P. 5 Fig. 3 Typical design of an RS 85 network Item Designation Computer 2 RS 85/RS 232 converter with RS 232/RS 85 cable 3 RS 85 bus connector with jumper Analyzers 5 RS 85 cable 6 RS 85 bus connector 7 RS 85 network 8 -pin DSUB plug Option: RS 85 repeater Ordering information SIPROM GA software German/English selectable during installation, comprising CD, with installation instructions, software product certificate and registration form Firmware retrofitting sets for older analyzers: ULTRAMAT 23 (prior to SW version 2.06) All languages (prior to SW version.) German English French Spanish Italian OXYMAT 6 (prior to SW version.) German English French Spanish Italian Order No. S760-B0-A C75-A3-S50 C75-A378-S50 C75-A378-S502 C75-A378-S503 C75-A378-S50 C75-A378-S505 C75-A380-S50 C75-A380-S502 C75-A380-S503 C75-A380-S50 C75-A380-S505 6 Siemens Catalog Extract PA 0 November 2002

7 General Communication PROFIBUS-DP/-PA Fig. Basic structure of a PROFIBUS system The term "Field bus" describes a digital communications system with which distributed field devices in a plant are networked together via one single cable, and connected at the same time to programmable controllers or to a process control system. PROFIBUS is the leading field bus on the market. The PROFIBUS-DP version is widely used for production automation because of its high transmission rate for relatively small data quantities per device, whereas PROFIBUS-PA particularly takes into account the features required for process engineering, e.g. large data quantities and application in potentially explosive atmospheres. User benefits can be found in the extremely high potentials for cost savings in all areas of the plant, covering configuring and commissioning, operation and maintenance, and up to later plant extensions. Operation of the gas analyzers from a control system or separate PC is possible using the SIMATIC PDM (Process Device Manager) operator input tool which is software executing under Windows 5/8/NT and which can also be incorporated into the SIMATIC PCS 7 process control system. This permits clear display of both the incorporation of devices into the system and the complex parameter structure of the analyzers, permitting operation to be carried out simply by clicking. The PROFIBUS user organization (PNO) is an independent international institution, and represents the interests of many vendors and users. In addition to services such as consultation, training and device certification, its prime task is the further development, standardization and promotion of the PROFIBUS technology. The definition of a binding functionality for a device class in a profile is a prerequisite for the uniform response of devices from different vendors, the so-called interoperability. The profile for analyzers was defined as binding at the end of, thus guaranteeing the interaction of all PROFIBUS-based devices in a plant. This profile defines the functionality of the analyzers in a block model: e.g. the physical block describes the measuring procedure, analyzer and vendor names, serial number and operating state (operation, maintenance). Various functional blocks contain the execution of specific functions such as the processing of measured values or alarms. The transducer blocks describe the functionality of the actual measuring procedure and its control, e.g. preprocessing of a measured value, correction of cross-interferences, characteristics, measuring ranges as well as switching and control procedures. Protocols define the data transmission between the stations on the bus. A differentiation is made between cyclic and acyclic services. Cyclic services are used to transmit time-critical data such as measured values and statuses. The acyclic services permit the scanning or modification of device parameters during operation. All gas analyzers of Series 6, and OXYMAT 6, as well as OXYMAT 6, CALOMAT 6 and ULTRAMAT 23, are suitable for PROFIBUS when fitted with the optional plug-in card (retrofitting also possible, see Ordering information). Siemens Catalog Extract PA 0 November

8 " unit Connections, assembly Gas and electrical connections Channel Channel 2 Channel Channel 2 Sample gas outlet Reference gas outlet Reference gas inlet Sample gas inlet 5-pin connector: Binary inputs and analog inputs/outputs -pin connector: RS 85 -pin interface socket (option): e.g. PROFIBUS 37-pin connector: Binary inputs and relay outputs (option board) Gas connections: stubs 6 mm or ¼" 25-pin connector: Binary inputs and relay outputs Power supply and miniature fuse Gas preparation (not included in delivery) Gas sampling device (heated if required) 2 Sample gas line (heated if required) 3 Gas cooler Coarse filter 5 Fine filter 6 Sample gas pump 7 Control valve, flow regulator 8 Flowmeter Condensation drain Fig. 5, " unit, gas and electrical connections shown at top, installation preparation with two separate gas sampling devices (external sample preparation, example) shown at bottom 8 Siemens Catalog Extract PA 0 November 2002

9 " unit Gas paths Internal gas paths, gas flow diagrams, basic layout Option Option VK MK EK Option 2 VK Option 2 EK MK 0 0 P 2 P 2 Channel 3 Channel Sample gas inlet 2 6 Sample gas outlet 3 7 Reference gas outlet 8 Reference gas inlet IR physics 0 Pressure switch in sample gas path Restrictor im sample gas path (pushed into hose) 2 Pressure sensor to correct variations in atmospheric pressure 3 Flowmeter Hose clamp Option / Option 2: can only be ordered for both channels together EK Receiver cell (detector) MK Sample cell VK Reference cell, flow-type IR physics Fig. 6 Gas path E-2P with sample gas monitoring (option 2) and flow-type reference cell (option ) 3 2 Option 3 P 0 Option 2 VK EK MK Sample gas inlet 2 Sample gas outlet 3 Reference gas outlet Reference gas inlet Pressure switch in sample gas path 0 Inlet restrictor im sample gas path Outlet restrictor in reference gas path 2 IR physics 3 Pressure switch in sample gas path Flowmeter in sample gas path 5 Restrictor im sample gas path (pushed into hose) 6 Pressure sensor to correct variations in atmospheric pressure EK Receiver cell (detector) MK Sample cell VK Reference cell, flow-type IR physics Fig. 7 Gas path E with sample gas monitoring (option 2) and reduced flow-type reference cell (option 3) Siemens Catalog Extract PA 0 November 2002

10 " unit Electrical connection Pin assignment Connector SUB-D F (RS 85) GND +5 V M M GND R_Level-N- NC RD/TD-N RD/TD-P R_Level-P- NC NC GND Possibility for connection of bus terminating resistors to pins 7 and. Connector SUB-D 5F M M M M GND Analog output 2-P Analog output 2-N Analog output -P Analog output -N NC NC Analog input 2-P Analog input 2-N Analog input -P Analog input -N Binary input 6-P Binary input 5-P Binary input 5 to 6-N GND only with 2-component version of the ULTRAMAT section Floating analog outputs (also with respect to one another), R L 750 W Pressure correction Pressure correction Interfering gas correction Interfering gas correction Floating via opto isolator "0" = 0 V (0 to.5 V) "" = 2 V (3 to 33 V) Non-floating analog inputs, 0 to 20 ma/500 W or 0 to 0 V (low-resistance) Connector SUB-D 25F M M GND Binary input -P Binary input 3-P Binary input 2-P Binary input -P Binary input to -N Relay 6 Relay 5 Relay Relay 3 Relay 2 Relay GND Floating via opto isolator "0" = 0 V (0 to.5 V) "" = 2 V (3 to 33 V) Contact loading max. 2 V/ A, AC/DC; relay contacts shown: de-energized relay coil Note: Cable and plug must be shielded and connected to chassis potential. Fig. 8, unit, pin assignment 0 Siemens Catalog Extract PA 0 November 2002

11 " unit Electrical connection Pin assignment (continued) Connector SUB-D 37F (option) M M GND NC NC Binary input -P Binary input 3-P Binary input 2-P Binary input -P Binary input 0-P Binary input -P Binary input 8-P Binary input 7-P Binary input 7 to -N Relay Relay 3 Relay 2 Relay Relay 0 Relay Relay 8 Relay 7 GND } ü ý þ Floating via opto isolator "0" = 0 V (0 to.5 V) "" = 2 V (3 to 33 V) Contact loading max. 2 V/ A, AC/DC; relay contacts shown: de-energized relay coil Note: Cable and plug must be shielded and connected to chassis potential. Connector SUB-D F -X0 PROFIBUS-DP optional Connector SUB-D M -X0 PROFIBUS-PA DGND CNTR-P/direction control RxD/TxD-P B RxD/TxD-N A VP /+ 5 V Pa-N(-) PA-P(+) (PA-N(-)) Fig., unit, pin assignment of Autocal board and PROFIBUS connectors Siemens Catalog Extract PA 0 November 2002

12 " unit Technical data Technical data General Measuring ranges Smallest possible measuring range Largest possible measuring span Characteristic Position of use, switchable internally and remotely; autoranging is also possible depending on application, e.g. CO: 0 to 0 vpm CO 2 : 0 to 5 vpm Depending on application Linearized Front panel vertical Conformity CE identification EN 5008-, EN Design, enclosure Dimensions see Fig. 0 Weight Approx. 5 kg (with IR-channel), Approx. 2 kg (with 2 IR-channels) Degree of protection IP 20 according to EN 6052 Electrical characteristics EMC interference immunity (ElectroMagnetic Compatibility) According to standard requirements of NAMUR NE2 (08/8) Electrical safety According to EN 600- overvoltage category III Power supply 00 to 20 V AC (rated range 0 V to 32 V), 8 to 63 Hz or 200 to 20 V AC (rated range 80 V to 26 V), 8 to 63 Hz Power consumption -channel unit: approx. 0 VA 2-channel unit: approx. 70 VA Fuses V V T/250 (7MB22).6T/250 (7MB223) 0.63T/250 (7MB22) T/250 (7MB223) Gas inlet conditions Perm. sample gas pressure for analyzers with hoses - without pressure switch 600 to 500 hpa (absolute) - with pressure switch 600 to 300 hpa (absolute) for analyzers with pipes 600 to 500 hpa (absolute) (without pressure switch) Sample gas flow 8 to 0 l/h (0.3 to.5 l/min) Sample gas temperature 0 to 50 C Sample gas humidity < 0 % RH ) or depending on application; non condensing Time response Warm-up period With amb. temperature < 30 min 2 ) Response time (T 0 time) Damping (electric time constant) Dead time (purging time of gas path in analyzer at l/min) Time for internal signal processing Dependent on length of analyzer cell, sample gas line and damping 0 to 00 s, programmable Approx. 0.5 to 5 s depending on version < s Pressure correction range Pressure sensor internal external Measuring response 2 ) Output signal fluctuation Zero drift Measured-value drift Repeatability Linearity error Influencing variables 3 ) Ambient temperature Sample gas pressure Sample gas flow Power supply Ambient conditions Electric inputs and outputs Analog output Relay outputs Analog inputs Binary inputs 600 to 200 hpa absolute 600 to 500 hpa absolute ± 0. % to ± % of smallest possible measuring range specified on rating plate depending on application with the unit electronic time constant (corresponds to ± 0.33 % with 2 σ) < % of measuring range/week < % of measuring range/week % of respective measuring range < 0.5 % of full-scale value < % of measuring range/0 K With pressure compensation: < 0.5 % of span/ % change in atmospheric pressure Without pressure compensation: <.5 % of span/ % change in atmospheric pressure Negligible < 0. % of output signal span with rated voltage ± 0 % Application-dependent influencing of measurement if ambient air contains measured component or crosssensitive gases 0/2/ to 20 ma, floating; max. load 750 Ω 6, with changeover contacts, freely selectable, e.g. for range identification; loading capacity: 2 V AC/DC/ A, floating, non sparking 2, designed for 0/2/ to 20 ma, for external pressure sensor and correction of influence of residual gas (correction of cross interferences) 6, designed for 2 V, floating, freely selectable, e.g. for range switching Serial interface RS 85 Options Autocal function with 8 additional binary inputs and 8 relay outputs, also with PROFIBUS-PA and PROFIBUS-DP Ambient conditions Perm. ambient temperature Permissible humidity -30 to +70 C during storage and transport, +5 to +5 ºC during operation < 0 C RH ) as annual average, during storage and transport ) ) RH: relative humidity. 2 ) Maximum accuracy achieved after 2 hours. 3 ) Referred to 000 hpa absolute sample gas pressure, 0.5 l/min sample gas flow and 25 C ambient temperature. ) Dew point must not be fallen below. 2 Siemens Catalog Extract PA 0 November 2002

13 " unit Dimensions Dimensions M Fig. 0, unit, dimensions in mm Siemens Catalog Extract PA 0 November

14 " unit Ordering data E, channel, IR-component Ordering data Order No. gas analyzer 7MB22- cannot be combined Order code -Z Single-channel unit for installation in cabinets A A 7 to measure one IR-component Gas connections for sample gas and reference gas Piping with outer diameter 6 mm A2 Piping with outer diameter ¼" - A20 Measured component 5 ) Possible with range codes CO to 30-7 A CO highly selective (with optical filter) 2 to 30-7 B CO (TÜV, see additional versions p. 22) - 7 X CO 2 0 to 30-7 C CH 3 to 30-7 D C 2 H 2 5 to 30-7 E C 2 H 5 to 30-7 F C 2 H 6 to 30-7 G C 3 H 6 to 30-7 H C 3 H 8 3 to 30-7 J C H 6 5 to 30-7 K C H 0 to 30-7 L C 6 H to 30-7 M SO 2 (TÜV, see additional versions p. 22) 3 to 30-7 N NO (TÜV, see additional versions p. 22) to 30-7 P NH 3 (dry) to 30-7 Q Q H 2 O 7 to R R N 2 O 3 to 30-7 S Smallest Largest Range measuring range measuring range code 0 to 5 vpm 0 to 00 vpm A 0 to 0 vpm 0 to 200 vpm B 0 to 20 vpm 0 to 00 vpm C 0 to 50 vpm 0 to 000 vpm D 0 to 00 vpm 0 to 000 vpm E 0 to 300 vpm 0 to vpm F 0 to 500 vpm 0 to vpm G 0 to 000 vpm 0 to vpm H 0 to vpm 0 to vpm J 0 to vpm 0 to vpm K 0 to vpm 0 to vpm L 0 to vpm 0 to vpm M 0 to % 0 to 3 % N 0 to % 0 to 0 % P 0 to 3 % 0 to 0 % Q 0 to 3 % 0 to 30 % R 0 to 5 % 0 to 5 % S 0 to 5 % 0 to 50 % T 0 to 0 % 0 to 30 % U 0 to 0 % 0 to 00 % V 0 to 30 % 0 to 00 % W Internal Sample cell Reference cell gas paths 6 ) (lining) (flow) Viton hose Aluminium Non-flow-type Flow-type Titanium pipe Tantalum Non-flow-type Flow-type with sample gas monitoring Viton hose Aluminium Non-flow-type Flow-type A20, A A20, A A20, A see next page Siemens Catalog Extract PA 0 November 2002

15 " unit Ordering data E, channel, IR-component Ordering data (continued) Order No. gas analyzer 7MB22- Single-channel unit for installation in cabinets A A 7 to measure one IR-component Additional electronics Without Autocal board With 8 additional binary inputs and outputs With serial interface for the automotive industry (AK) With 8 binary inputs/outputs and PROFIBUS-PA interface With 8 binary inputs/outputs and PROFIBUS-DP interface Power supply 00 V to 20 V AC, 8 to 63 Hz V to 20 V AC, 8 to 63 Hz Operating software and documentation German A A 0 English A A French A A 2 Spanish A A 3 Italian A A Ordering data Further versions Please add -Z to Order No. and specify Order code RS 85/RS 232 converter Flow-type reference side with reduced flow, 6 mm ) Flow-type reference side with reduced flow, ¼ ) Slide rails (2 rails) Set of Torx tools, socket spanner TAG labels (customer-defined inscriptions) Kalrez gaskets in sample gas path Customer acceptance (in factory before delivery) 2 ) Clean for O 2 service (specially cleaned gas path) Drift recording 3 ) Measuring range in plain text, if different from standard setting ) Special setting (only in conjunction with an application No., e.g. extended measuring range outside standard ranges) Extended special setting (only in conjunction with an application No., e.g. determination of cros-interferences, supplement calibration curves) TÜV version according to 7. BlmSch Order code A A20 A2 A3 A32 B03 B0 Y0 Y02 Y03 Y Y2 Y3 Y7 Retrofitting sets RS 85/Ethernet converter RS 85/RS 232 converter Autocal function with 8 binary inputs/outputs Autocal function with 8 binary inputs/outputs and PROFIBUS-PA Autocal function with 8 binary inputs/outputs and PROFIBUS-DP C75-A336-D6 C75-Z58-U C75-A380-D5 A5E A5E Footnotes see page 2 Siemens Catalog Extract PA 0 November

16 " unit Ordering data E-2P, 2 channels, 2 IR-ccomponents Ordering data Order No. gas analyzer 7MB223- cannot be combined Order code -Z Two-channel unit for installation in cabinets to measure two IR-components Gas connections for sample gas and reference gas Piping with outer diameter 6 mm A2, A, A2, A25 Piping with outer diameter ¼" - A20, A0, A22, A23 Channel Possible with Measured component 5 ) range codes CO to 30-7 A CO highly selective (with optical filter) 2 to 30-7 B CO (TÜV, see additional versions p. 22) - 7 X CO 2 0 to 30-7 C CH 3 to 30-7 D C 2 H 2 5 to 30-7 E C 2 H 5 to 30-7 F C 2 H 6 to 30-7 G C 3 H 6 to 30-7 H C 3 H 8 3 to 30-7 J C H 6 5 to 30-7 K C H 0 to 30-7 L C 6 H to 30-7 M SO 2 (TÜV, see additional versions p. 22) 3 to 30-7 N NO (TÜV, see additional versions p. 22) to 30-7 P NH 3 (trocken) to 30-7 Q Q H 2 O 7 to R R N 2 O 3 to 30-7 S Smallest Largest Range measuring range measuring range code 0 to 5 vpm 0 to 00 vpm A 0 to 0 vpm 0 to 200 vpm B 0 to 20 vpm 0 to 00 vpm C 0 to 50 vpm 0 to 000 vpm D 0 to 00 vpm 0 to 000 vpm E 0 to 300 vpm 0 to vpm F 0 to 500 vpm 0 to vpm G 0 to 000 vpm 0 to vpm H 0 to vpm 0 to vpm J 0 to vpm 0 to vpm K 0 to vpm 0 to vpm L 0 to vpm 0 to vpm M 0 to % 0 to 3 % N 0 to % 0 to 0 % P 0 to 3 % 0 to 0 % Q 0 to 3 % 0 to 30 % R 0 to 5 % 0 to 5 % S 0 to 5 % 0 to 50 % T 0 to 0 % 0 to 30 % U 0 to 0 % 0 to 00 % V 0 to 30 % 0 to 00 % W Internal Sample cell Reference cell gas paths 6 ) (lining) (flow) Viton hose Aluminium Non-flow-type Flow-type Titanium pipe Tantalum Non-flow-type Flow-type with sample gas monitoring Viton hose Aluminium Non-flow-type Flow-type A20, A2, A0, A A20, A2, A0, A A20, A2, A0, A see next page 6 Siemens Catalog Extract PA 0 November 2002

17 Ordering data (continued) Order No. gas analyzer 7MB223- Two-channel unit for installation in cabinets to measure two IR-components Additional electronics Without Autocal board With 8 additional binary inputs and outputs for channel With 8 additional binary inputs and outputs for channel With 8 addit. binary inputs and outputs for chan. and chan With serial interface for the automotive industry (AK) With additional 8 binary inputs/outputs for chan. and chan and PROFIBUS-PA interface With additional 8 binary inputs/outputs for chan. and chan and PROFIBUS-DP interface Power supply 00 V to 20 V AC, 8 to 63 Hz V to 20 V AC, 8 to 63 Hz Channel 2 Possible with Measured component 5 ) range codes CO to A CO highly selective (with optical filter) 2 to B CO (TÜV, see additional versions p. 22) X CO 2 0 to C CH 3 to D C 2 H 2 5 to E C 2 H 5 to F C 2 H 6 to G C 3 H 6 to H C 3 H 8 3 to J C H 6 5 to K C H 0 to L C 6 H to M SO 2 (TÜV, see additional versions p. 22) 3 to N NO (TÜV, see additional versions p. 22) to P NH 3 (dry) to Q Q H 2 O 7 to R R N 2 O 3 to S Smallest Largest Range measuring range measuring range code 0 to 5 vpm 0 to 00 vpm A 0 to 0 vpm 0 to 200 vpm B 0 to 20 vpm 0 to 00 vpm C 0 to 50 vpm 0 to 000 vpm D 0 to 00 vpm 0 to 000 vpm E 0 to 300 vpm 0 to vpm F 0 to 500 vpm 0 to vpm G 0 to 000 vpm 0 to vpm H 0 to vpm 0 to vpm J 0 to vpm 0 to vpm K 0 to vpm 0 to vpm L 0 to vpm 0 to vpm M 0 to % 0 to 3 % N 0 to % 0 to 0 % P 0 to 3 % 0 to 0 % Q 0 to 3 % 0 to 30 % R 0 to 5 % 0 to 5 % S 0 to 5 % 0 to 50 % T 0 to 0 % 0 to 30 % U 0 to 0 % 0 to 00 % V 0 to 30 % 0 to 00 % W see next page " unit Ordering data E-2P, 2 channels, 2 IR-ccomponents cannot be combined Siemens Catalog Extract PA 0 November

18 " unit Ordering data E-2P, 2 channels, 2 IR-ccomponents Ordering data (continued) Ordering data Order No. gas analyzer Two-channel unit for installation in cabinets 7MB to measure two IR-components Operating software and documentation German English French Spanish Italian Further versions Please add -Z to Order No. and specify Order code RS 85/RS 232 converter Flow-type reference side with reduced flow, 6 mm (channel ) ) Flow-type reference side with reduced flow, ¼ (channel ) ) Flow-type reference side with reduced flow, 6 mm (channel 2) ) Flow-type reference side with reduced flow, ¼ (channel 2) ) Connection pipe made of titanium 6 mm, complete with screwed gland, for sample gas side Connection pipe made of titanium 6 mm, complete with screwed gland, for reference gas side Connection pipe made of titanium ¼, complete with screwed gland, for sample gas side Connection pipe made of titanium ¼, complete with screwed gland, for reference gas side Slide rails (2 rails) Set of Torx tools, socket spanner TAG labels (customer-defined inscriptions) Kalrez gaskets in sample gas path (channel ) Kalrez gaskets in sample gas path (channel 2) Customer acceptance (in factory before delivery) 2 ) Clean for O 2 service (specially cleaned gas path, channel + 2) Drift recording 3 ) Measuring range in plain text, if different from standard setting ) Special setting (only in conjunction with an application No., e.g. extended measuring range outside standard ranges) Extended special setting (only in conjunction with an application No., e.g. determination of cros-interferences, supplement calibration curves) TÜV version according to 7. BlmSch Retrofitting sets RS 85/Ethernet converter RS 85/RS 232 converter Autocal function with 8 binary inputs/outputs Autocal function with 8 binary inputs/outputs and PROFIBUS-PA Autocal function with 8 binary inputs/outputs and PROFIBUS-DP Footnotes see page 2 Order code A A20 A2 A0 A A22 A23 A2 A25 A3 A32 B03 B0 B05 Y0 Y02 Y03 Y Y2 Y3 Y7 C75-A336-D6 C75-Z58-U C75-A380-D5 A5E A5E Siemens Catalog Extract PA 0 November 2002

19 Ordering data Order No. " unit Ordering data E-2R/3K channel, 2 components or 2 channels, 3 components gas analyzer 7MB22- cannot be combined Order code -Z Single or dual-channel unit for installation in cabinets to measure two or three IR-components Gas connections for sample gas and reference gas Piping with outer diameter 6 mm A2, A2, A25, A Piping with outer diameter ¼" - A20, A22, A23, A0 Measuring Smallest Largest component 5 ) measuring range measuring range CO 0 to 00 ppm 0 to 000 ppm NO 0 to 00 ppm 0 to 000 ppm CO 0 to 300 ppm 0 to ppm NO 0 to 300 ppm 0 to ppm CO 0 to 000 ppm 0 to ppm NO 0 to 000 ppm 0 to ppm for CO/NO TÜV versions see page 22 CO 2 0 to 00 ppm 0 to 000 ppm CO 0 to 00 ppm 0 to 000 ppm CO 2 0 to 300 ppm 0 to ppm CO 0 to 300 ppm 0 to ppm CO 2 0 to 000 ppm 0 to ppm CO 0 to 000 ppm 0 to ppm CO 2 0 to ppm 0 to ppm CO 0 to ppm 0 to ppm CO 2 0 to % 0 to 0 % CO 0 to % 0 to 0 % CO 2 0 to 3 % 0 to 30 % CO 0 to 3 % 0 to 30 % CO 2 0 to 0 % 0 to 00 % CO 0 to 0 % 0 to 00 % CO 2 0 to 0 % 0 to 00 % CH 0 to 0 % 0 to 00 % CO 2 0 to 00 ppm 0 to 000 ppm NO 0 to 00 ppm 0 to 000 ppm CO 2 0 to 300 ppm 0 to ppm NO 0 to 300 ppm 0 to ppm Internal Sample cell Reference cell gas paths 6 ) (lining) (flow) Viton hose Aluminium Non-flow-type Flow-type Titanium pipe Tantalum Non-flow-type Flow-type with sample gas monitoring Viton hose Aluminium Non-flow-type Flow-type - 7 A A - 7 A B - 7 A C - 7 B A - 7 B B - 7 B C - 7 B D - 7 B E - 7 B F - 7 B G - 7 C G - 7 D A - 7 D B A20, A2, A0, A A20, A2, A0, A A20, A2, A0, A Additional electronics (Autocal board) Without Autocal board With 8 additional binary inputs and outputs for channel With 8 additional binary inputs and outputs for channel With serial interface for the automotive industry (AK), channel With serial interface for the automotive industry (AK), channel + 2 With additional 8 binary inputs/outputs for channel and PROFIBUS-PA interface With additional 8 binary inputs/outputs for chan. and chan and PROFIBUS-PA interface With additional 8 binary inputs/outputs for channel and PROFIBUS-DP interface With additional 8 binary inputs/outputs for chan. and chan and PROFIBUS-DP interface Power supply 00 V to 20 V AC, 8 to 63 Hz V to 20 V AC, 8 to 63 Hz see next page Siemens Catalog Extract PA 0 November 2002

20 " unit Ordering data E-2R/3K channel, 2 components or 2 channels, 3 components Ordering data (continued) gas analyzer Single or dual-channel unit for installation in cabinets to measure two or three IR-components Channel 2 Possible with Measured component 5 ) range codes Order No. 7MB22- cannot be combined Without channel W W CO to A CO highly selective (with optical filter) 2 to B CO (TÜV, see additional versions p. 22) X CO 2 0 to C CH 3 to 30 D C 2 H 2 5 to E C 2 H 5 to F C 2 H 6 to G C 3 H 6 to H C 3 H 8 3 to J C H 6 5 to K C H 0 to L C 6 H to M SO 2 (TÜV, see additional versions p. 22) 3 to N NO (TÜV, see additional versions p. 22) to P NH 3 (dry) to Q Q H 2 O 7 to R R N 2 O 3 to S Smallest Largest Range measuring range measuring range code Without channel X 0 to 5 vpm 0 to 00 vpm A 0 to 0 vpm 0 to 200 vpm B 0 to 20 vpm 0 to 00 vpm C 0 to 50 vpm 0 to 000 vpm D 0 to 00 vpm 0 to 000 vpm E 0 to 300 vpm 0 to vpm F 0 to 500 vpm 0 to vpm G 0 to 000 vpm 0 to vpm H 0 to vpm 0 to vpm J 0 to vpm 0 to vpm K 0 to vpm 0 to vpm L 0 to vpm 0 to vpm M 0 to % 0 to 3 % N 0 to % 0 to 0 % P 0 to 3 % 0 to 0 % Q 0 to 3 % 0 to 30 % R 0 to 5 % 0 to 5 % S 0 to 5 % 0 to 50 % T 0 to 0 % 0 to 30 % U 0 to 0 % 0 to 00 % V 0 to 30 % 0 to 00 % W Operating software and documentation German English French Spanish Italian Siemens Catalog Extract PA 0 November 2002

21 " unit Ordering data E-2R/3K channel, 2 components or 2 channels, 3 components Ordering data Further versions Please add -Z to Order No. and specify Order code RS 85/RS 232 converter Flow-type reference side with reduced flow, 6 mm (channel ) ) Flow-type reference side with reduced flow, ¼ (channel ) ) Flow-type reference side with reduced flow, 6 mm (channel 2) ) Flow-type reference side with reduced flow, ¼ (channel 2) ) Connection pipe made of titanium 6 mm, complete with screwed gland, for sample gas side Connection pipe made of titanium 6 mm, complete with screwed gland, for reference gas side Connection pipe made of titanium ¼, complete with screwed gland, for sample gas side Connection pipe made of titanium ¼, complete with screwed gland, for reference gas side Slide rails (2 rails) Set of Torx tools, socket spanner TAG labels (customer-defined inscriptions) Kalrez gaskets in sample gas path (channel ) Kalrez gaskets in sample gas path (channel 2) Customer acceptance (in factory before delivery) 2 ) Clean for O 2 service (specially cleaned gas path, channel + 2) Drift recording 3 ) Measuring range in plain text, if different from standard setting ) Special setting (only in conjunction with an application No., e.g. extended measuring range outside standard ranges) Extended special setting (only in conjunction with an application No., e.g. determination of cros-interferences, supplement calibration curves) TÜV version according to 7. BlmSch Retrofitting sets RS 85/RS 232 converter RS 85/Ethernet converter Autocal function with 8 binary inputs/outputs for channel or channel 2 Autocal function with 8 binary inputs/outputs and PROFIBUS-PA for channel or channel 2 Autocal function with 8 binary inputs/outputs and PROFIBUS-DP for channel or channel 2 Order code A A20 A2 A0 A A22 A23 A2 A25 A3 A32 B03 B0 B05 Y0 Y02 Y03 Y Y2 Y3 Y7 C75-Z58-U C75-A336-D6 C75-A380-D5 A5E A5E ) Cannot be combined with non-flow-type reference side. 2 ) Customer acceptance: ½ day at factory in presence of customer. The following work is carried out: comparison of analyzer with ordering data; linearization check (zero, mid-point value and full-scale value); reproducibility check with calibration gas (recording in each case on XT recorder, logging of results). 3 ) Drift recording: an XT recording is supplied when the analyzer is delivered: zero drift with 6 hours continuous operation and sensitivity drift (largest measuring range) with 6 hours continuous operation. ) Standard setting: smallest possible measuring range 25 % of largest possible range in % or 50 % of largest possible range ppm largest range } (vpm) 5 ) Further measured components on request. 6 ) Further materials on request. Note: conversion factors with optional selection of dimension ppm (vpm) into mg/m 3 at normal conditions (20 C, 03 hpa) SO 2 : 0.38 ppm mg/m 3 NO: 0.80 ppm mg/m 3 CO: 0.86 ppm mg/m 3. Siemens Catalog Extract PA 0 November

22 " unit Ordering data Additional versions for TÜV units Single component Component CO (TÜV) SO 2 (TÜV) NO (TÜV) Measuring range identification Smallest measuring range from 0 to... Example for ordering E, TÜV component CO measuring range 0 to 50/000 mg/m 3 with hoses, non-flow-type reference side without automatic calibration (Autocal) 230 V; German 7MB22-0XD00-AA0-Z +Y7 Largest measuring range from 0 to... Smallest measuring range from 0 to... Largest measuring range from 0 to... Smallest measuring range from 0 to... Largest measuring range from 0 to... C 75 mg/m mg/m 3 D 50 mg/m mg/m mg/m mg/m 3 E 500 mg/m mg/m 3 00 mg/m mg/m 3 F 300 mg/m mg/m mg/m mg/m mg/m mg/m 3 G 500 mg/m mg/m mg/m mg/m 3 H 000 mg/m mg/m mg/m mg/m mg/m mg/m 3 K 3000 mg/m mg/m 3 0 g/m 3 00 g/m mg/m mg/m 3 P 0 g/m 3 00 g/m 3 30 g/m g/m 3 0 g/m 3 00 g/m 3 R 30 g/m g/m 3 00 g/m g/m 3 30 g/m g/m 3 V 00 g/m 3 60 g/m g/m g/m 3 00 g/m g/m 3 2 components in series (2R) Component CO (TÜV) NO (TÜV) Measuring range identification Smallest measuring range from 0 to... Largest measuring range from 0 to... Example for ordering E-2R/3K, TÜV components CO/NO + SO 2 measuring range CO: 0 to 75/000 mg/m 3 NO: 0 to 200/2000 mg/m 3 SO 2 : 0 to 75/500 mg/m 3 with hoses, non-flow-type reference side without automatic calibration (Autocal) 230 V; German 7MB22-0AA00-NC0-Z +Y7 Note: for 3 components take both tables into consideration. Smallest measuring range from 0 to... Largest measuring range from 0 to... AA 75 mg/m mg/m mg/m mg/m 3 AB 300 mg/m mg/m mg/m mg/m 3 AC 000 mg/m mg/m mg/m mg/m 3 22 Siemens Catalog Extract PA 0 November 2002

23 Field unit Connections, assembly Gas and electrical connections (unit underside) a b c d e 6 8 Gas connections Electrical connections 2 3 Sample gas inlet Sample gas outlet Reference gas inlet Reference gas outlet Clamping ring connection for pipe Ø 6 mm or ¼" a - c d e Signal line (analog + digital): Pg 6 Interface connection: Pg 3.5 Supply connection: Pg Purging gas inlets/outlets Barometric input sensor connection Stubs Ø 0 mm or 3 /8 " Stub Ø ¼" Gas preparation (not included in delivery) Gas sampling device (heated if required) 2 Sample gas line (heated if required) 3 Gas cooler Coarse filter 5 Fine filter 6 Sample gas pump 7 Control valve, flow regulator 8 Flowmeter Condensation drain 3 Fig., field unit, gas and electrical connections shown at top, installation preparation with external gas preparation (example) shown at bottom Siemens Catalog Extract PA 0 November

24 Field unit Gas paths Internal gas paths, gas flow diagrams, basic layout Option 3 2 Sample gas inlet 2 Sample gas outlet 3 Reference gas inlet Reference gas outlet 5 Pressure sensor to correct variations in atmospheric pressure VK MK EK P 5 EK Receiver cell (detector) MK Sample cell VK Reference cell, flow-type IR physics Fig. 2 Gas path F with flow-type reference cell (option) Option VK MK EK 2 Sample gas inlet 2 Sample gas outlet 3 Reference gas intlet Reference gas outlet (reduced flow: 3-0 ml/min, 3000 to 000 hpa absolute) 5 Pressure switch in reference gas path 6 Inlet restrictor in reference gas path 7 Outlet restrictor in reference gas path 8 Pressure sensor to correct variations in atmospheric pressure P 8 EK Receiver cell (detector) MK Sample cell VK Reference cell, flow-type IR physics Fig. 3 Gas path F with reduced flow-type reference cell (option) 2 Siemens Catalog Extract PA 0 November 2002

25 Field unit Electrical connection Pin assignment Connector SUB-D F (RS 85) GND +5 V M M GND R_Level-N- NC RD/TD-N RD/TD-P R_Level-P- NC NC GND Possibility for connection of bus terminating resistors to pins 7 and Terminal block A M 2 GND M M M M 500 W M Relay Relay 2 Relay 3 Relay Relay 5 Relay 6 Binary input to -N Binary input -P Binary input 2-P Binary input 3-P Binary input -P GND GND Binary input 5 to 6-N Binary input 5-P Binary input 6-P Analog input -N Analog input -P Analog input 2-N Analog input 2-P NC Analog output -N Analog output -P Analog output 2-N Analog output 2-P GND Contact loading max. 2 V/ A, AC/DC; relay contacts shown: de-energized relay coil Floating via opto isolator "0" = 0 V (0 to.5 V) "" = 2 V (3 to 33 V) Floating via opto isolator "0" = 0 V (0 to.5 V) "" = 2 V (3 to 33 V) Interfering gas corr. Non-floating Interfering gas corr. analog inputs, 0 to 20 ma or Pressure correction 0 to 0 V (lowresistance 500 Pressure correction W) Analog outputs floating Component Component 2 (if present) Note: Cable and plug must be shielded and connected to chassis potential. Fig. F, field unit, connector and terminal assignment Siemens Catalog Extract PA 0 November

Continuous Gas Analyzers, extractive

Continuous Gas Analyzers, extractive General Flüssigkeitsanalysengeräte Overview The single-channel or dual-channel gas analyzers operate according to the NDIR two-beam alternating light principle and measure gases highly selectively whose

More information

1 Overview. Continuous Gas Analyzers, extractive ULTRAMAT 6. General information

1 Overview. Continuous Gas Analyzers, extractive ULTRAMAT 6. General information General information Overview The single-channel or dual-channel gas analyzers operate according to the NDIR two-beam alternating light principle and measure gases highly selectively whose absorption bands

More information

ULTRAMAT 6. General information 2/29

ULTRAMAT 6. General information 2/29 Siemens AG 009 General information Overview The single-channel or dual-channel gas analyzers operate according to the NDIR two-beam alternating light principle and measure gases highly selectively whose

More information

1 Overview. Extractive continuous process gas analysis Series 6 ULTRAMAT 6. General information

1 Overview. Extractive continuous process gas analysis Series 6 ULTRAMAT 6. General information General information Overview The single-channel or dual-channel gas analyzers operate according to the NDIR two-beam alternating light principle and measure gases highly selectively whose absorption bands

More information

1 Overview ULTRAMAT/OXYMAT 6. General information

1 Overview ULTRAMAT/OXYMAT 6. General information Overview General information The gas analyzer is a practical combination of the ULTRAMAT 6 and OXYMAT 6 analyzers in a single enclosure. The ULTRAMAT 6 channel operates according to the NDIR twobeam alternating

More information

Continuous Gas Analyzers, extractive

Continuous Gas Analyzers, extractive General Siemens AG 008 Overview The gas analyzer can measure up to 4 gas components at once: A maximum of three infrared sensitive gases such as CO, CO, NO, SO, CH 4 and in addition O with an electrochemical

More information

ULTRAMAT/OXYMAT 6. General information 2/71

ULTRAMAT/OXYMAT 6. General information 2/71 Siemens AG 011 General information Overview The gas analyzer is a practical combination of the ULTRAMAT 6 and OXYMAT 6 analyzers in a single enclosure. The ULTRAMAT 6 channel operates according to the

More information

1 Overview. Continuous Gas Analyzers, extractive CALOMAT 6. 1/148 Siemens AP US Edition. General information

1 Overview. Continuous Gas Analyzers, extractive CALOMAT 6. 1/148 Siemens AP US Edition. General information General information Overview Special versions Special applications In addition to the standard combinations, special applications are also available upon request (e.g. higher sample gas pressure up to

More information

Continuous Gas Analyzers, extractive OXYMAT 64

Continuous Gas Analyzers, extractive OXYMAT 64 Siemens AG 206 Overview The gas analyzer is used for the trace measurement of oxygen. Benefits High linearity Compact design Open interface architecture (RS 85, RS 232, PROFIBUS) SIPROM GA network for

More information

Continuous Gas Analyzers, extractive

Continuous Gas Analyzers, extractive Overview Plug-in and field device The gas analyzer is primarily used to identify a gas component quantity (e.g. H 2, N 2, Cl 2, HCl, NH 3 ) in binary or quasi-binary gas mixtures. The is specially designed

More information

Extractive continuous process gas analysis Series 6 OXYMAT 64

Extractive continuous process gas analysis Series 6 OXYMAT 64 Overview Siemens AG 208 Extractive continuous process gas analysis General information Design 9" rack unit with HU for installation - In hinged frame - In cabinets with or without telescope rails Front

More information

Continuous Gas Analyzers, extractive

Continuous Gas Analyzers, extractive General information Siemens AG 009 Overview The gas analyzer is a practical combination of the ULTRAMAT 6 and OXYMAT 6 analyzers in a single enclosure. The ULTRAMAT 6 channel operates according to the

More information

Extractive continuous process gas analysis Series 6 ULTRAMAT/OXYMAT 6

Extractive continuous process gas analysis Series 6 ULTRAMAT/OXYMAT 6 Siemens AG 208 Overview The gas analyzer is a practical combination of the ULTRAMAT 6 and OXYMAT 6 analyzers in a single enclosure. The ULTRAMAT 6 channel operates according to the NDIR twobeam alternating

More information

OXYMAT 6. General information 1/117

OXYMAT 6. General information 1/117 Overview Siemens AG 203 General information Special versions Special applications Besides the standard combinations, special applications concerning material in the gas path, material in the sample cells

More information

Extractive continuous process gas analysis Series 6 OXYMAT 61

Extractive continuous process gas analysis Series 6 OXYMAT 61 Siemens AG 08 Extractive continuous process gas analysis OXYMAT 6 Overview The measuring principle of the OXYMAT 6 gas analyzers is based on the paramagnetic alternating pressure method and is used to

More information

Continuous Gas Analyzers, extractive OXYMAT 61

Continuous Gas Analyzers, extractive OXYMAT 61 Siemens AG 06 OXYMAT 6 Overview The measuring principle of the OXYMAT 6 gas analyzers is based on the paramagnetic alternating pressure method and is used to measure oxygen in gases in standard applications.

More information

1 Overview. Continuous Gas Analyzers, extractive OXYMAT 6. 1/98 Siemens AP US Edition. General information

1 Overview. Continuous Gas Analyzers, extractive OXYMAT 6. 1/98 Siemens AP US Edition. General information General information Overview Special versions Special applications Besides the standard combinations, special applications concerning the material in the gas path and the material in the sample chambers

More information

Continuous Gas Analyzers, extractive

Continuous Gas Analyzers, extractive General information Overview The function of the gas analyzers is based on the paramagnetic alternating pressure method and are used to measure oxygen in gases. Benefits Paramagnetic alternating pressure

More information

OXYMAT 6 Gas Analyzers for the Determination of Oxygen

OXYMAT 6 Gas Analyzers for the Determination of Oxygen Gas Analyzers for the Determination of Oxygen General Application Design ode of operation Reference gases, cross interferences Versions - Wetted parts Communication 9 9 unit 9 Connections, assembly 0 Gas

More information

1 Overview. Extractive continuous process gas analysis Series 6 FIDAMAT 6. General information

1 Overview. Extractive continuous process gas analysis Series 6 FIDAMAT 6. General information General information Overview The gas analyzer is suitable for the determination of the total hydrocarbon content in the air and high-boiling gas mixtures. Benefits The gas analyzer is distinguished by

More information

1 Overview. Continuous Gas Analyzers, extractive FIDAMAT 6. General information

1 Overview. Continuous Gas Analyzers, extractive FIDAMAT 6. General information General information Overview The gas analyzer is suitable for the determination of the total hydrocarbon content in the air and high-boiling gas mixtures. Benefits The gas analyzer is distinguished by

More information

Continuous Gas Analyzers, extractive

Continuous Gas Analyzers, extractive General Process analytics Overview The gas analyzer is suitable for the determination of the total hydrocarbon content in the air and high-boiling gas mixtures. Benefits The gas analyzer stands out for

More information

OXYMAT 64. Gas analyzer for measurements of trace oxygen 7MB2041. Operating Instructions June Continuous gas analysis

OXYMAT 64. Gas analyzer for measurements of trace oxygen 7MB2041. Operating Instructions June Continuous gas analysis Gas analyzer for measurements of trace oxygen 7MB2041 Operating Instructions June 2008 Continuous gas analysis General information 1 Description 2 Continuous gas analysis Gas analyzer for measurement

More information

1 General information Device description Scope Task definition Explosion protection, Device variants...

1 General information Device description Scope Task definition Explosion protection, Device variants... Handbuch/Manual/Manuel/Manuale 12/2002 gas analysis CALOMAT 6 für die Applikation Turbogenerator-Überwachung for the turbo generator monitoring application pour l application Surveillance de turboalternateurs

More information

Gas Analysis Isn t Exactly Your Only Priority? Luckily For You, It s Ours. SIPROCESS GA700 effortless gas analytics from Siemens. siemens.

Gas Analysis Isn t Exactly Your Only Priority? Luckily For You, It s Ours. SIPROCESS GA700 effortless gas analytics from Siemens. siemens. Gas Analysis Isn t Exactly Your Only Priority? Luckily For You, It s Ours. SIPROCESS GA700 effortless gas analytics from Siemens. Easier Than Ever SIPROCESS GA700 The New Generation of Continuous Gas Analytics.

More information

Continuous Gas Analyzers, extractive SIPROCESS GA700

Continuous Gas Analyzers, extractive SIPROCESS GA700 Siemens AG 0 Overview Application Application areas Depending on the analyzer modules installed, the device is predominantly used in the following sectors: Chemical industry Petrochemicals Steel Cement

More information

1 Overview ULTRAMAT 23. General information

1 Overview ULTRAMAT 23. General information Siemens AG 03 Overview General information Up to four gas components can be measured simultaneously with the gas analyzer: up to three infrared-active gases such as CO, CO, NO, SO, CH 4, plus O with an

More information

MEGAS 2.0. Gas analysis with direct C-Level Calculation and Bus-Connection. Data sheet

MEGAS 2.0. Gas analysis with direct C-Level Calculation and Bus-Connection. Data sheet Data sheet MEGAS 2.0 Gas analysis with direct C-Level Calculation and Bus-Connection Mesa Industrie-Elektronik GmbH Neckarstraße 19, D-45768 Marl info@mesa-gmbh.de +49 (0) 2365-97 45 1-0 +49 (0) 2365-97

More information

Continuous Gas Analyzer, extractive

Continuous Gas Analyzer, extractive Siemens AG 011 Continuous Gas Analyzer, extractive / Introduction /5 ULTRAMAT 3 /5 General information /18 19" rack unit and portable version /36 Documentation /36 Suggestions for spare parts /37 ULTRAMAT

More information

GasSense NDIR User Manual

GasSense NDIR User Manual INDEX INDEX... 1 1. OVERVIEW... 2 2. TECHNICAL DATA... 3 3. SPECIFICATIONS... 4 4. PRODUCT DESCRIPTION... 5 4.1 Mechanical details... 5 4.2 Piping... 7 4.3 Connections... 7 5. INSTALLATION... 10 6. CALIBRATION

More information

FTC130 Transmitter. Operating Manual

FTC130 Transmitter. Operating Manual Seite 1 von 11 FTC130 Transmitter Fast Thermal Conductivity Analyzer Operating Manual 1.09KD180724CWI1V05 Messkonzept GmbH Seite 2 von 11 1. Intended Use... 3 2. Description... 4 3. Measuring gases and

More information

EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases

EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases P r o d u c t i n f o r m at i o n EuroFID Total Hydrocarbon Analyzer Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases Proven Analyzer Technology Measuring total

More information

Continuous Gas Analyzers, extractive

Continuous Gas Analyzers, extractive Siemens AG 206 /2 Introduction /5 SIPROCESS GA700 /5 Base unit /3 Analyzer module ULTRAMAT 7 /9 Analyzer module OXYMAT 7 /30 Analyzer module CALOMAT 7 /36 ULTRAMAT 23 /36 General information /49 9" rack

More information

SITRANS P measuring instruments for pressure

SITRANS P measuring instruments for pressure SITRANS P measuring instruments for pressure Z series for gage pressure Siemens AG 008 Overview Design The main components of the pressure transmitter are: Brass housing with silicon measuring cell and

More information

Columbus Instruments

Columbus Instruments 0215-003M Portable O 2 /CO 2 /CH 4 Meter User s Manual Columbus Instruments 950 NORTH HAGUE AVENUE TEL:(614) 276-0861 COLUMBUS, OHIO 43204, USA FAX:(614) 276-0529 1 www.colinst.com TOLL FREE 1-800-669-5011

More information

Pressure transmitter PASCAL Ci4

Pressure transmitter PASCAL Ci4 Pressure transmitter PASCAL Ci4 for general application,type Series CI4100 Features Pressure transmitter for the measuring of relative and absolute pressures of gases, vapors and liquids High-resolution

More information

Continuous Gas Analyzers, extractive

Continuous Gas Analyzers, extractive Siemens AG 204 /2 Introduction /5 SIPROCESS GA700 /5 Base unit /8 Analyzer module OXYMAT 7 /28 ULTRAMAT 23 /28 General information /4 9" rack unit and portable version /59 Documentation, Suggestions for

More information

Sample conditioning equipment

Sample conditioning equipment Sample conditioning equipment /2 Filters /2 Room air filter /2 Front mounting filter /3 Coalescence filter / Universal filter and moisture sensor /6 Stainless steel filter housing /7 Condensation removal

More information

SIL Safety Manual. ULTRAMAT 6 Gas Analyzer for the Determination of IR-Absorbing Gases. Supplement to instruction manual ULTRAMAT 6 and OXYMAT 6

SIL Safety Manual. ULTRAMAT 6 Gas Analyzer for the Determination of IR-Absorbing Gases. Supplement to instruction manual ULTRAMAT 6 and OXYMAT 6 ULTRAMAT 6 Gas Analyzer for the Determination of IR-Absorbing Gases SIL Safety Manual Supplement to instruction manual ULTRAMAT 6 and OXYMAT 6 ULTRAMAT 6F 7MB2111, 7MB2117, 7MB2112, 7MB2118 ULTRAMAT 6E

More information

Continuous Gas Analyzers, extractive

Continuous Gas Analyzers, extractive Siemens AG 205 /2 Introduction /5 SIPROCESS GA700 /5 Base unit /3 Analyzer module ULTRAMAT 7 /8 Analyzer module OXYMAT 7 /29 Analyzer module CALOMAT 7 /35 ULTRAMAT 23 /35 General information /48 9" rack

More information

Transmitter CS 21 Operation Manual

Transmitter CS 21 Operation Manual Transmitter CS 21 Operation Manual Content Page For your Safety 3 General Description 3 Detection Principle 4 Operational Notes 4 Design 4 Mounting Position of CS21 5 Mounting 6 Installation of Electrical

More information

Continuous gas analysis. SIPROCESS GA700 Rack-mounted device. Introduction 1. General safety instructions 2. Description 3. Application planning 4

Continuous gas analysis. SIPROCESS GA700 Rack-mounted device. Introduction 1. General safety instructions 2. Description 3. Application planning 4 Introduction 1 General safety instructions 2 Continuous gas analysis SIPROCESS GA700 Operating Instructions Description 3 Application planning 4 Installing/removing modules in the rack-mounted enclosure

More information

Model GFC 7000T CO 2 Analyzer (Addendum to GFC 7000TA Manual, PN 07272)

Model GFC 7000T CO 2 Analyzer (Addendum to GFC 7000TA Manual, PN 07272) Manual Addendum Model GFC 7000T CO 2 Analyzer (Addendum to GFC 7000TA Manual, PN 07272) P/N M07273 DATE 06/11/13 TELEDYNE ELECTRONIC TECHNOLOGIES Analytical Instruments 16830 Chestnut Street City of Industry,

More information

Mass Flow Meter (MFM) for gases

Mass Flow Meter (MFM) for gases Mass Flow Meter (MFM) for gases Type can be combined with Inline MFM for nominal flow rates from 25 l N /min to 1,500 l N /min; 1/4 to 3/4 High accuracy Fast settling time Fieldbus option Special version

More information

Pneumatic high-pressure controller Model CPC7000

Pneumatic high-pressure controller Model CPC7000 Calibration technology Pneumatic high-pressure controller Model CPC7000 WIKA data sheet CT 27.63 Applications Healthcare and avionics industry Industry (laboratory, workshop and production) Transmitter

More information

Continuous Gas Analyzers, extractive ULTRAMAT 23

Continuous Gas Analyzers, extractive ULTRAMAT 23 Siemens AG 06 Overview Up to four gas components can be measured simultaneously with the gas analyzer: up to three infrared-active gases such as CO, CO, NO, SO, CH 4, plus O with an electrochemical oxygen

More information

DF-550E PROCESS ANALYSERS APPLICATIONS FEATURES

DF-550E PROCESS ANALYSERS APPLICATIONS FEATURES PROCESS ANALYSERS DF-550E The DF-550E Nano Trace oxygen analyser is a Coulometric sensor based analyser designed to measure oxygen as a contaminant at ultra trace levels in ultra high purity electronic

More information

Pneumatic high-pressure controller Model CPC7000

Pneumatic high-pressure controller Model CPC7000 Calibration technology Pneumatic high-pressure controller Model CPC7000 WIKA data sheet CT 27.63 Applications Automotive and avionics industry Industry (laboratory, workshop and production) Transmitter

More information

Mass Flow Controller (MFC) for Gases

Mass Flow Controller (MFC) for Gases Mass Flow Controller (MFC) for Gases Direct flow measurement with CMOSens technology for nominal flow rates from 0 ml N to 0 l N High accuracy and reproducibility Ingress protection IP Type can be combined

More information

EasyLine Continuous Gas Analyzers. So smart, they re simple

EasyLine Continuous Gas Analyzers. So smart, they re simple EasyLine Continuous Gas Analyzers So smart, they re simple Reliable Economic Powerful EasyLine is both a powerful and affordable line of instruments for the monitoring of gas concentrations in numerous

More information

C-Flow Coriolis Mass Flow Meters

C-Flow Coriolis Mass Flow Meters Coriolis Mass Flow Meters Ready for Take Off The New Compact C-Flow Küppers Elektromechanik GmbH The C-Flow The C-Flow Coriolis Mass Meters consist of two components: KCE Transmitter KCM Transducer 2 KEM

More information

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure Z series for gage pressure Overview Design The main components of the pressure transmitter are: Brass housing with silicon measuring cell and electronics plate Process connection Electrical connection

More information

DM01. Please visit our website: Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

DM01. Please visit our website:  Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05 DM0 Battery Powered Stainless Steel Sensor class 0.05 Nominal pressure from 0 00 mbar up to 0... 00 bar Special characteristics modular sensor concept data logger graphic display stainless steel housing

More information

DF-310E PROCESS ANALYSERS APPLICATIONS FEATURES

DF-310E PROCESS ANALYSERS APPLICATIONS FEATURES PROCESS ANALYSERS DF-310E The DF-310E is a Coulometric sensor based oxygen analyzer designed to measure trace and percent level oxygen in pure and multi-gas backgrounds for process and quality control

More information

Extractive continuous process gas analysis ULTRAMAT 23

Extractive continuous process gas analysis ULTRAMAT 23 Siemens AG 08 Overview Up to four gas components can be measured continuously at the same time with the gas analyzer. The device can be equipped with the following sensors: IR detector for IR-active gases

More information

ABB MEASUREMENT & ANALYTICS DATA SHEET. Advance Optima AO2000 Series Continuous gas analyzers

ABB MEASUREMENT & ANALYTICS DATA SHEET. Advance Optima AO2000 Series Continuous gas analyzers ABB MEASUREMENT & ANALYTICS DATA SHEET Advance Optima AO2000 Series Continuous gas analyzers 2 AO2000 CONTINUOUS GAS ANALYZERS DS/AO2000-EN REV. A Measurement made easy Modular continuous gas analyzers

More information

Pneumatic spool valve islands

Pneumatic spool valve islands Pneumatic spool valve islands P7.GB.R MEGA SPOOL VALVE ISLANDS MEGA pneumatic spool valve islands offer maximum performance along with flexibility, easy installation and simple operation. Due to their

More information

Installation and Operation Manual

Installation and Operation Manual Manual Static pressure transducer with controller Differential static pressure transducer with analog output and optional PI control mode Large diaphragm element with differential transformer Transducer

More information

JUMO dtrans O2 01 Two-wire Transmitter for dissolved oxygen (DO)

JUMO dtrans O2 01 Two-wire Transmitter for dissolved oxygen (DO) Data Sheet 202610 Page 1/12 JUMO dtrans O2 01 Two-wire Transmitter for dissolved oxygen (DO) with optional terminal box or operating unit Type 202610 Two-wire transmitter JUMO dtrans O2 01 Brief description

More information

973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS

973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS Precise and Stable SF 6 Gas Analyzer Simultaneous measurement of humidity, SF 6 purity and SO 2 concentration Integrated gas recovery system with automatic pump back Fully automated SF 6 gas testing Fundamental

More information

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05 Battery Powered Stainless Steel Sensor class 0.05 Nominal pressure from 0 00 mbar up to 0... 00 bar Special characteristics modular sensor concept data logger graphic display stainless steel housing Ø

More information

HumiSys HF High Flow RH Generator

HumiSys HF High Flow RH Generator HumiSys HF High Flow RH Generator Designed, built, and supported by InstruQuest Inc. Versatile Relative Humidity Generation and Multi-Sensor System The HumiSys HF is a high flow version of the previously

More information

Instruction Manual. Biogas Analyzer InCa Bio 04

Instruction Manual. Biogas Analyzer InCa Bio 04 Instruction Manual Biogas Analyzer InCa Bio 04 Instruction Manual InCa Bio 04 contents - IMPORTANT - Refer to the safety intructions before installation begins 2 Manual InCa Bio 04 07-10-10 R2 Table of

More information

Analogue and Digital Mass Flow Meters and Controllers for Gases MASS-STREAM

Analogue and Digital Mass Flow Meters and Controllers for Gases MASS-STREAM Analogue and Digital Mass Flow Meters and Controllers for Gases MASS-STREAM M+W Instruments Your partner Key Facts M+W Instruments was founded in 1988 and has always specialised in thermal mass flow meters

More information

Gas density monitor With integrated transmitter Model GDM-100-TI

Gas density monitor With integrated transmitter Model GDM-100-TI SF 6 gas solutions Gas density monitor With integrated transmitter Model GDM-100-TI grid Products WIKA data sheet SP 60.05 for further approvals see page 5 Applications Gas density monitoring of closed

More information

Pressure Measurement Single-range transmitters for general applications

Pressure Measurement Single-range transmitters for general applications Siemens A 207 Overview Application The SITRANS P Compact pressure transmitter is designed for the special requirements of the food, pharmaceutical and biotechnology industries. The use of high-grade materials

More information

Navigator 500 Dissolved oxygen analyzer. Measurement made easy. Accurate and reliable measurement of dissolved oxygen in high purity water

Navigator 500 Dissolved oxygen analyzer. Measurement made easy. Accurate and reliable measurement of dissolved oxygen in high purity water Data sheet DS/ADS550 EN Rev. C Navigator 500 Dissolved oxygen analyzer Measurement made easy Accurate and reliable measurement of dissolved oxygen in high purity water Monitors both low and high dissolved

More information

Mass Flow Controller (MFC) for Gases

Mass Flow Controller (MFC) for Gases Mass Flow Controller (MFC) for Gases Bypass MFC with capillary technology for nominal flow rates from 5 ml N /min to 15 l N /min Applicable for aggressive gases Compact design and digital communication

More information

High-performance submersible pressure transmitter For level measurement Model LH-20

High-performance submersible pressure transmitter For level measurement Model LH-20 Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-20 WIKA data sheet PE 81.56 Applications Deep well and borehole measurements Groundwater

More information

High-performance submersible pressure transmitter For level measurement in hazardous areas Model LH-20

High-performance submersible pressure transmitter For level measurement in hazardous areas Model LH-20 Electronic pressure measurement High-performance submersible pressure transmitter For level measurement in hazardous areas Model LH-20 WIKA data sheet PE 81.56 Applications Deep well and borehole measurements

More information

Transmitter CS 21 Operation Manual

Transmitter CS 21 Operation Manual Transmitter CS 21 Operation Manual 1194 Oak Valley Drive, Suite 20, Ann Arbor, MI 48108 800-959-0573 734-769-1888 Content Page For your Safety 3 General Description 3 Detection Principle 4 Operation 4

More information

Continuous Gas Analysis ULTRAMAT 23 Supplement 1 for Operating Instructions C79000-G52xx-C Product Information

Continuous Gas Analysis ULTRAMAT 23 Supplement 1 for Operating Instructions C79000-G52xx-C Product Information Continuous Gas Analysis ULTRAMAT 23 Supplement 1 for Operating Instructions C79000-G52xx-C216-03 Product Information Introduction Device model and validity This supplement describes the device, ULTRAMAT

More information

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars. Simply a question of better measurement SCHMIDT Flow Sensor SS 20.261 The cost-effective alternative in pressurised systems up to 10 bars. Compressed air technology Industrial processes A cost analysis

More information

Precision pressure sensor Basic version Model CPT6020

Precision pressure sensor Basic version Model CPT6020 Calibration Precision pressure sensor Basic version Model CPT6020 WIKA data sheet CT 25.13 Applications Calibration technology High-accuracy pressure monitoring Pressure sensing in critical applications

More information

Instruction Manual Dräger MSI P7 and MSI P7 plus

Instruction Manual Dräger MSI P7 and MSI P7 plus Dräger MSI GmbH Rohrstraße 32 58093 Hagen Tel.: +49-2331 / 9584-0 Fax: +49-2331 / 9584-29 e-mail: info@draeger-msi.de D 923; Edition 2011-01-01 Content 1. General Hints Page 4 2. The Instrument 2.1 Front

More information

Supplementary Operator s Manual 42/24-14 EN Rev. 3

Supplementary Operator s Manual 42/24-14 EN Rev. 3 Advance Optima Continuous Gas Analyzers AO2000 Series with Uras26, Magnos206, Caldos25, Caldos27 Designed per Category 3G for Measurement of Flammable Gases ( Safety Concept ) and Non-flammable Gases Supplementary

More information

Measurement of Low GAS & Liquid Flows

Measurement of Low GAS & Liquid Flows Measurement of Low GAS & Liquid Flows The Measurement Measurement with a float in a tapered borosilicate glass tube. Series 2100 with a 100 mm flow tube Series 2150 with a 150 mm flow tube Series 2300

More information

FIDAMAT 5E-ANM, -ANM-P gas analyzers for Measurement of Total Hydrocarbon Content 7MB , -6.. Instruction Manual

FIDAMAT 5E-ANM, -ANM-P gas analyzers for Measurement of Total Hydrocarbon Content 7MB , -6.. Instruction Manual FIDAMAT 5E-ANM, -ANM-P gas analyzers for Measurement of Total Hydrocarbon Content 7MB420-3.., -6.. Instruction Manual Order no. C79000-B5276-C30-03 Contents Page Introduction 4. General 4.2 Staff Qualifications

More information

Mass Flow Meter (MFM) for Gases

Mass Flow Meter (MFM) for Gases 873 Mass Flow Meter (MFM) for Gases Direct flow measurement by MEMS- Technology for nominal flow rates from 1 ml N /min to 8 l N /min (N 2 ) High accuracy Short response time Compact design and digital

More information

Mass Flow Controller (MFC) for Gases

Mass Flow Controller (MFC) for Gases Mass Flow Controller (MFC) for Gases Type 8713 can be combined with... Direct flow measurement by MEMS- Technology for nominal flow rates from 1 ml N /min to 8 l N /min (N 2 ) High accuracy and repeatability

More information

ETd 04. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. Type: ETd 04. class 0.05

ETd 04. Battery Powered Precision Digital Gauge. Stainless Steel Sensor.  Type: ETd 04. class 0.05 Battery Powered Stainless Steel Sensor class 0.05 Nominal pressure from 0 100 mbar up to 0... 400 bar Special characteristics modular sensor concept data logger graphic display stainless steel housing

More information

Precision digital pressure gauge Model CPG1000

Precision digital pressure gauge Model CPG1000 Calibration technology Precision digital pressure gauge Model CPG1000 WIKA data sheet CT 10.01 Applications Oil and gas industry Maintenance and service facilities Calibration service companies and service

More information

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI US Edition

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI US Edition Siemens AG 07 SITRANS LH00 Transmitter for hydrostatic level Overview Function U const. p U I EM The pressure transmitter SITRANS LH00 is a submersible sensor for hydrostatic level measurement. The pressure

More information

Plasma. Argon Production Helium Liquefaction Truck Loading Pure Gas Bottling

Plasma. Argon Production Helium Liquefaction Truck Loading Pure Gas Bottling SERVOPRO Plasma The SERVOPRO Plasma is a Plasma Emission Detector based analyser designed to continuously measure Nitrogen in pure Argon for process and quality control in Argon production within Cryogenic

More information

Oxymax COS61/COS61D. Technical Information

Oxymax COS61/COS61D. Technical Information Technical Information Oxymax / Dissolved oxygen measurement Optical sensor acc. to the fluorescence quenching principle, with or without Memosens protocol Application The continuous measurement of the

More information

Mass Flow Controller (MFC) for Gases

Mass Flow Controller (MFC) for Gases Mass Flow Controller (MFC) for Gases Bypass MFC with capillary technology for nominal flow rates from ml N /min to 0 l N /min Applicable for aggressive gases Fieldbus option Type 870 can be combined with...

More information

Gas Module for Series GMS800

Gas Module for Series GMS800 Title Page SUPPLEMENTARY OPERATING INSTRUCTIONS Gas Module for Series GMS800 Components Application Information Operating Data Document Information Described Product Product name: Gas Module Basic device:

More information

Pressure Measurement Single-range transmitters for general applications

Pressure Measurement Single-range transmitters for general applications Siemens AG 07 Overview Function U const. p U I EM Sensor Connection for auxiliary power supply Vent pipe with humidity filter Protective conductor connection/ Equipotential bonding Diaphragm The pressure

More information

FIDAMAT 5E gas analyzer for Measurement of Total Hydrocarbon Content 7MB1420 Instruction Manual

FIDAMAT 5E gas analyzer for Measurement of Total Hydrocarbon Content 7MB1420 Instruction Manual FIDAMAT 5E gas analyzer for Measurement of Total Hydrocarbon Content 7MB420 Instruction Manual Order no. C79000-B5276-C06-04 Contents Page Introduction 4. General 4.2 Staff Qualifications 4 2 Application

More information

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc. The HumiSys RH Generator Designed, built, and supported by InstruQuest Inc. Versatile Relative Humidity Generation and Multi-Sensor System The new HumiSys with single or dual RH probes capabilities is

More information

Series 6517 Katharometers. The ideal equipment for Process Monitoring and Control. Robust no moving parts. Designed for continuous industrial use

Series 6517 Katharometers. The ideal equipment for Process Monitoring and Control. Robust no moving parts. Designed for continuous industrial use Data sheet Katharometers The ideal equipment for Process Monitoring and Control Designed for continuous industrial use Long working life Suitable for flammable gases CENELEC certified (ATEX) to EExia IIC

More information

IDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

IDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05 IDL0 Battery Powered Precision Digital Gauge for Leak Testing Stainless Steel Sensor class 0.05 Nominal pressure from 0 00 mbar up to 0... 00 bar Special characteristics modular sensor concept data logger

More information

deltaflowc deltaflowc Venturi or Probe

deltaflowc deltaflowc Venturi or Probe deltaflowc Mass Flowmeter for Gases - Multivariable with ultra fast dp, p and T-sensors - Compact, accurate and user-friendly - Ideal for OEMs deltaflowc Venturi or Probe Precise mass flow metering deltaflowc

More information

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI Siemens AG 06 SITRANS LH00 Transmitter for hydrostatic level Overview Function U const. p U I EM The pressure transmitter SITRANS LH00 is a submersible sensor for hydrostatic level measurement. The pressure

More information

EPP4 Pressure Regulator Basic G 1/4"

EPP4 Pressure Regulator Basic G 1/4 EPP4 Pressure Regulator Basic G 1/4" Flow Curve 1/4" Dimensions Outlet pressure - bar 9 8 7 6 5 4 3 2 1 0 0 20 40 60 70 80 100 120 Flow rate - Nm 3 /h The male connector adopted on the EPP4 is a standard

More information

Expert Hydrostatic Level Transmitters

Expert Hydrostatic Level Transmitters Expert Hydrostatic s General Features MJK Expert hydrostatic level transmitters are designed for level measurement by submerging the transmitter in open channels, drains and tanks. Expert hydrostatic level

More information

AMT-Ex Dewpoint Transmitter

AMT-Ex Dewpoint Transmitter AMT-Ex Dewpoint Transmitter Instruction Manual Alpha Moisture Systems Alpha House 96 City Road Bradford BD8 8ES England Tel: +44 1274 733100 Fax: +44 1274 733200 email: mail@amsytems.co.uk web: www.amsystems.co.uk

More information

High-performance submersible pressure transmitter For level measurement Model LH-20

High-performance submersible pressure transmitter For level measurement Model LH-20 Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-20 WIKA data sheet PE 81.56 Applications Deep well and borehole measurements Groundwater

More information

FLAMMABLE GAS SENSOR/TRANSMITTER

FLAMMABLE GAS SENSOR/TRANSMITTER FLAMMABLE GAS SENSOR/TRANSMITTER Plant safety protection for flammable gases. F E A T U R E S Fixed gas monitoring for point source hazards and perimeter protection in arduous duty and exposed locations.

More information

Electronic gas volume corrector model DGVC-04

Electronic gas volume corrector model DGVC-04 Electronic gas volume corrector model DGVC-04 1. Introduction The following user s manual gives information about the installation, configuration, usage and storage of the electronic gas volume corrector

More information