ACID FAST BACTERIA MICROBIOLOGY STAINER / CYTOCENTRIFUGE WESCOR, INC
|
|
- Catherine Goodman
- 5 years ago
- Views:
Transcription
1 ACID FAST BACTERIA STAINER / CYTOCENTRIFUGE MICROBIOLOGY WESCOR, INC
2 he Newest Innovation Is Here! AFB Staining has never been so easy, fast, or economical The Aerospray Microbiology Acid-Fast Bacteria (AFB) Slide Stainer/Cytocentrifuge provides significant advantages over hand staining or automated dip-type stainers, including speed, economy, consistent performance, and no cross-contamination. The new Aerospray AFB stainer performs either carbol fuchsin or fluorescence procedures by exchanging reagents and selecting the appropriate program on the keyboard. This unique device provides two essential instruments in one economical package. With Wescor s optional Cytopro rotor, the Aerospray stainer becomes a superb cytocentrifuge featuring 8- slide capacity and keyboard programmability. All at a fraction of the cost of a stand alone cytocentrifuge! Aerospray, Cytopro, and Cytopad are trademarks of Wescor, Inc. U.S. Patent Numbers 4,004,550; 4,089,989; 5,009,185; 5,252,228.
3 Economical The Aerospray is exceptionally sparing in reagent consumption, giving you versatile full or partial load programming options that significantly reduce reagent volumes and costs required for staining different sized loads. An optional 30 slide carousel brings high volume economy within reach of every laboratory. Rapid Performance With a cycle time as short as 4.5 minutes, the Aerospray stainer can process more than 150 slides per hour (up to 400 with the optional 30- slide carousel). No more waiting for slides to dry they re ready to view when the staining cycle ends. Easy to Use Simply select from 6 different stain settings and start the staining cycle. That s all you have to do because the stainer takes over from there, precisely controlling all phases of the stain cycle with consistent reproducibility. Carbol Fuchsin or Fluorescence Staining on Demand With a few keystrokes and a change of reagents the AFB stainer can be configured for Kinyoun, Ziehl-Neelsen, auramine or auramine/rhodamine staining methods. No Cross Contamination In all Aerospray stainers, fresh reagent is applied as an atomized spray on slides mounted in a rotating carousel. Specimens contact only fresh, precisely metered stain from separate spray nozzles. No cross-contamination is possible. Optional Rotor for Cytocentrifugation For the cost of the optional Cytopro rotor, the Aerospray stainer becomes a superb cytocentrifuge with 8 slide capacity and keyboard programmability at a fraction of the cost of purchasing a stand-alone cytocentrifuge.
4 Ready for the Microscope in Minutes
5 The Wescor AFB Staining Process A erospray stains microscope slides smeared with materials containing acid-fast microorganisms such as culture materials, body fluids, or exudates. Wescor reagents are tailored to give superb results in the Aerospray stainer. The Aerospray stainer provides a choice of staining cycles ranging from 1 to 6, allowing you to compensate for thick specimens, or other possible variables. Fixation Specimens are heat fixed according to traditional procedures prior to staining in the Aerospray. Primary Stain At the beginning of the staining cycle, the slides are sprayed with the primary stain (carbol fuchsin or fluorochrome) that penetrates and stains the specimens. Excess stain is then spun off and washed away with deionized water to prevent precipitate formation. Decolorizing Acid alcohol decolorizer is then applied to remove the primary stain from the non acid-fast bacteria and surrounding debris. The decolorization is stopped with a water wash and a short spin. Counterstain The counterstain is then applied to stain the non-acidfast organisms. Excess counterstain is then removed with a water wash and a short spin. Drying The slides are spun at about 950 RPM for 45 seconds. This draws air through the machine and dries the slides. Slides emerge from the stainer dry and ready for the microscope. With its rapid staining cycle and high throughput capability, the Aerospray stainer is a convenient, cost effective way to stain mycobacteria.
6 CYTOPRO Cytocentrifuge Rotor
7 W With the optional Cytopro rotor, the Aerospray stainer becomes a cytocentrifuge at a fraction of the cost of a stand alone cytocentrifuge. There s no modification or fiddling involved. Simply remove the staining carousel and replace it with the Cytopro rotor. The self-contained sealed rotor loads easily in a biological safety cabinet. The rotor and sample chambers are autoclavable. Sample chambers are competitively priced so you can economically dispose of them. THE CYTOPRO CHAMBER The chamber s unique design combines ease of use with superb cell recovery. -Perfect Alignment. The Cytopad absorption pad snaps quickly between the chamber and the frame. This guarantees that the chamber bore is always correctly aligned. No fumbling, and no cell loss due to poor alignment. -Better Flow Control. Each Cytopad features a specially compressed ring around the center hole. This compression controls fluid flow and improves the repeatability of fluid absorption. -Dual Sample Port. Two ports, one in the sample well and one in the tunnel allows you to introduce prewetting fluids to increase cell recovery. -Chamber Caps. You can load samples directly through the chamber caps to prevent spilling of hazardous samples. -Two Fluid Absorption Rates. The white Cytopad is for faster absorption of viscous or debrisfilled suspension fluids. The tan pad is used to slow fluid absorption for improved cell recovery in non viscous fluids such as urine or CSF. EASY TO ASSEMBLE AND LOAD Assembling the Cytopro chamber is easy; chambers and Cytopads fit securely together with foolproof precision. No more cell loss due to misaligned filter cards. You ll be surprised how simply chambers and slides load into the rotor. The ends of each slide are fully visible to you for accurate patient identification. The rotor bowl s shallow profile makes sample loading more convenient than with a deep rotor. Simply pipette sample fluid directly into the sample well (maximum sample size: 0.5 ml) or through vents in the chamber caps. The semi-transparent sample chambers allow visual confirmation of correct sample volume. THE CHOICE IS YOURS Cytopro delivers the versatility you need to satisfy a wide variety of sample treating requirements: - Unparalleled ease of use - Simple and flexible programming - Superior sample chamber design - Choice of two fluid absorption rates - Convenient prewetting capability - Safety and reliability Finally, you have the flexibility to control the cytocentrifugation process and to set the level of convenience. The choice is yours. Caution! Due to the hazards of airborne mycobacteria, samples must be inactivated before processing in the Cytopro or any other cytocentrifuge.
8 Instrument Specifications Aerospray Microbiology Acid-Fast Bacteria Slide Stainer/Cytocentrifuge Model 7720 Slide Carousel Capacity Carousel Rotation Speed Cytocentrifuge Rotor Speed Display Touch Pad Controls 12 or 30 slides Reagent application 20 RPM, slide drying approximately 950 RPM Programmable, 100 to 2000 RPM 4 line by 16 character alpha-numeric LCD dot-matrix 6 staining selections, 10 Numeric Programming Keys, Run Stop, Clean, Prog, CytoCent, Volume Test Reagent Consumption Ranges from 0.7 to 4.0 ml. Medium settings will use 1 to 2 (combined, excluding water) ml per slide Operating Time 3.7 to 10.6 minutes depending on system and settings Dimensions (W x H x D) 56 cm x 24 cm x 53 cm (22 x 9.5 x 21 ) Clearance Height (lid open) 58 cm (23 ) Weight Electrical Requirements Drain Connection Safety 17.6 kg (39 lb) 100V, 120V, 220V or 240V 50 to 60 Hz, 75 watts Nipple on rear panel Lid interlock: Lid must be closed, and is locked down during operation. Cytopro Cytocentrifuge Rotor Cat. No. AC Capacity Weight 8 chambers and slides 1.3 kg (2.8 lb) Dimensions (Dia. x H) 23 cm x 4.8 cm (9.0 x ) For information regarding Aerospray automatic stainers contact: WESCOR, INC 459 South Main Street, Logan, Utah USA TELPHONE: FAX: sales@wescor.com COPYRIGHT WESCOR, INC 1998 PRINTED USA NOV PB18A48
AN EXCITING NEW CONCEPT MICROBIOLOGY SLIDE STAINER/ CYTOCENTRIFUGE BIOMEDICAL PRODUCTS WESCOR, INC
AN EXCITING NEW CONCEPT MICROBIOLOGY SLIDE STAINER/ CYTOCENTRIFUGE BIOMEDICAL PRODUCTS WESCOR, INC T he Newest Innovation Is Here! Gram staining has never been so easy fast & economical The Aerospray Microbiology
More informationБерг АБ Тел. (495) , факс (495) Turning Ideas Into Engineered Solutions KAYDON RING & SEAL, INC.
Turning Ideas Into Engineered Solutions RING & SEAL, INC. K-CBS Series Circumferential Barrier Seals Kaydon s high performance circumferential barrier seals back up DGS systems with performance & economy.
More informationTissue-Tek Prisma Plus & Tissue-Tek Glas TM g2
Tissue-Tek Prisma Plus & Tissue-Tek Glas TM g2 Automated Slide Stainer & Coverslipper Imagine great time saving, supreme flexibility and high reliability in staining and glass coverslipping 2 We empower
More informationUser Guide. Pall Laboratory Manifold. For laboratory use. Not for use in a manner other than indicated. Introduction. Regulatory References
User Guide Pall Laboratory Manifold For laboratory use. Not for use in a manner other than indicated. Introduction Application and Intended Use The membrane filtration (MF) technique is a method of analyzing
More informationVIAFLO 96. Electronic 96 Channel Hand Held Pipettor
VIAFLO 96 Electronic 96 Channel Hand Held Pipettor VIAFLO 96 Unique Multichannel microplate pipetting is a growing task because of the need to increase productivity and improve the quality of the data
More informationFAST EVAPORATION AT NORMAL PRESSURE
FAST EVAPORATION AT NORMAL PRESSURE FAST EVAPORATION BY BLOWING-DOWN... The VAPORNADO Plus blow-down system is an innovative and efficient instrument for the evaporation of samples and fractions at normal
More informationImagine... full flexibility linked to high capacity. Tissue-Tek Prisma & Film. Automated Slide Stainer & Coverslipper
Imagine... full flexibility linked to high capacity Tissue-Tek Prisma & Film Automated Slide Stainer & Coverslipper Get linked, get started... Now as Tissue-Tek Film Coverslipper With the next step in
More informationSeries Environmental Chambers
3119-600 Series Environmental Chambers Challenges in Non-Ambient Testing Testing at non-ambient temperatures adds another layer of challenges to your testing laboratory. Ensuring you get accurate and stable
More information250 ton mt Lattice Crawler Crane
250 ton 226.8 mt Lattice Crawler Crane Heavy duty combination top section for conventional and luffing jib configuration Bar pendants & boom walkway 320 hp Cummins QSL9 Tier IV Final Transport weight is
More informationImagine... full flexibility linked to high capacity
Imagine... full flexibility linked to high capacity Get linked, get started... Now as easy as turning pages Tissue-Tek Film Coverslipper With the next step in automation, Sakura provides the user with
More informationXDF BURNERS DUAL FUEL EXCESS AIR BURNER FEATURES DESCRIPTION EXCESS AIR OPERATION
DUAL FUEL EXCESS AIR BURNER MODEL: 3610, 3651 Revision: 0 FEATURES Burns all fuel gases or light oils Nozzle mix design for on ratio control or excess air 350% excess air all sizes on gas or oil Turndown
More informationNovelBright LED Illuminator
NovelBright LED Illuminator Instruction Manual version NS01_11 Instruction Manual This LED illuminator is suitable for research use only. It must be used by specialized personnel that know the health risks
More informationWHEATON. Peristaltic Pumps. Advancing the Science of Liquid Handling
WHEATON Peristaltic Pumps Advancing the Science of Liquid Handling WHEATON Peristaltic Pumps Advancing the Science of Liquid Handling Highly intuitive Icon Driven User Interface enables fast, easy setup
More informationOffering more. Series
Offering more Series 3000 SAFE Prevent any burn risks and work in complete safety. Thanks to a unique «cold nozzle» system, the gun remains cool during use (patented system). PRACTICAL Large, solid hanger
More informationBasic & Controlled Atmosphere Glove Boxes
I N T R O D U C T I O N Precise Basic and Controlled Atmosphere Glove Boxes provide a leak-tight environment for work with contamination-sensitive materials. Precise Basic Glove Boxes are simple, economical
More informationHTHP Viscometer. Features DRILLING FLUIDS EQUIPMENT
DRILLING FLUIDS EQUIPMENT For over 30 years OFI Testing Equipment (OFITE) has provided instruments and reagents for testing drilling fluids, well cements, completion fluids, and wastewater. In addition
More informationThe Next Generation. Pulse Duplicator HDT-500. Medical Device Testing & Equipment Simulation Platforms Silicone Vessels
The Next Generation Pulse Duplicator HDT-500 Medical Device Testing & Equipment Simulation Platforms Silicone Vessels Backed by nearly 40 years of experience, the next generation pulse duplicator/pulsatile
More informationTransferpette. Lightweight precise rugged reliable!
Lightweight precise rugged reliable! Transferpette Solutions for S cience F I R S T C L A S S B R A N D The Transferpette S microliter pipettes provide all features required for pipetting in Life Science
More informationScrew Compressors 11-22kW
INDUSTRIALS GROUP Screw Compressors 11-22kW KSA Plus Fixed Speed, KSV Variable Speed Smart and affordable CHAMPION COMPRESSED AIR TECHNOLOGIES KSA Plus Screw Compressors Up to 45 C ambient temperature
More informationTransferpette. Lightweight precise rugged reliable!
Lightweight precise rugged reliable! Transferpette Solutions for S cience F I R S T C L A S S B R A N D The Transferpette S microliter pipettes provide all features required for pipetting in Life Science
More informationTradition & Technology
Gaterotor Support Gaterotor Single Screw Compressors Design & Operation Bearing Bearings Main Screw Parallex Slide System The VSM Single Screw Compressor has one main rotor and two gaterotors. All bearings
More informationtel: fax: web:
Tri-Flex 2 Five-Cell Permeability Test System For high volume commercial laboratory testing, the Tri-Flex 2 Five-Cell Permeability Test System offers the user the capabilities to test up to five samples
More informationSuperClear 15mL and 50mL Centrifuge Tubes
SuperClear 15mL and 50mL Centrifuge Tubes Prevents breakage & leakage during high-speed centrifugation Easy-to-read graduations for accurate measurements Patented, extra large, smear-resistant writing
More informationHigh Pressure Asher HPA-S
High Pressure Asher An ingenious concept Anton Paar Pioneer and leading developer in the field of sample preparation Anton Paar has developed and produced sample preparation instruments to the highest
More informationThe All New DIAMOND & DIAMOND BT
The All New DIAMOND & DIAMOND BT. Specs The Diamond The Diamond BT Type Badminton Badminton & Tennis Pulling Method Constant Pull Constant Pull Tension Range 10 38 lbs 10 88 lbs Tension Increments 0.1
More informationInstruction Manual Updated 7/26/2011 Ver. 2.2
4-Unit Model MB HTHP Filter Press #171-50-4: 115-Volt #171-51-4: 230-Volt Instruction Manual Updated 7/26/2011 Ver. 2.2 OFI Testing Equipment, Inc. 11302 Steeplecrest Dr. Houston, Texas 77065 U.S.A. Tele:
More informationYour local gas generation partner. Precision series Modular gas generation solution for GC.
Your local gas generation partner Precision series Modular gas generation solution for GC www.peakscientific.com Perform with Precision Specifically designed and engineered for GC laboratory applications,
More informationDIAGNOSTIC CARDIOLOGY
DIAGNOSTIC CARDIOLOGY For Your Procedural Needs Manufactured to the Highest Standards, Customised to Your Specific Needs MEDLINE PROCEDURE PACKS The items contained within this brochure are perfect for
More informationSeries 7250 Ruska High-Speed Digital Pressure Controller. GE Sensing. Features
Features Pressure ranges from 0 to 5 and 0 to 3000 psi (0 to 400 mbar and 0 to 210 bar) xi and 7250i provide advanced precision of 0.005% of reading provides 0.003% of full scale precision Stability: 0.0075%
More informationBACTRON Anaerobic Chambers The Complete Environmental Microbiology Workstation Anaerobic, Hypoxic, & other Gas Environments
BACTRON Anaerobic Chambers The Complete Environmental Microbiology Workstation Anaerobic, Hypoxic, & other Gas Environments No gloves. No jars or bags. Room temperature working conditions. True comfort.
More informationChemistry - Scale-up F.32. Lara TM - Controlled - Lab Reactor. The Concept
The Concept The concept behind Lara was to develop a flexible, affordable, easy-to-use CLR system. Lara incorporates many unique features that simplify the user s interaction saving time and money and
More informationP3000 Series. Pneumatic Deadweight Testers Model P3000. Technical Data. Features
P3000 Series Pneumatic Deadweight Testers P3000 Technical Data Features Pressure ranges from Vacuum through 2 000 psi (140 bar) Accuracy better than 0.015 % of reading. (Increased accuracy option of 0.008
More informationShandon Cytospin 4 Cytocentrifuge
Shandon Cytospin 4 Cytocentrifuge Thin-layer Cell Preparation System Analyze Detect Measure Control Shandon Cytospin 4 Cytocentrifuge The ultimate thin-layer cell preparation system. The Shandon Cytospin
More informationSampling Equipment Catalog. MicroPurge Low-Flow Pump Control
MicroPurge Low-Flow Pump Control Sampling Equipment Catalog 10 MicroPurge Controls The MicroPurge Controller (U.S. Patent Number 6,508,310) revolutionizes low-flow sampling with advanced logic control
More informationTraysealer T 100. Tray packaging in the smallest space
Traysealer T 100 Tray packaging in the smallest space MULTIVAC T 100 Traysealer T 100 Tray packaging in the smallest space The compact, semiautomatic Traysealer T 100 easily and economically packs products
More informationTourniquet System. Ideal for single or bi-lateral orthopaedic surgery and pain management
Tourniquet System Ideal for single or bi-lateral orthopaedic surgery and pain management The AT4 Electronic Tourniquet: A state-of-the-art dual channel electronic tourniquet with integral power supply
More informationStandard Operating and Maintenance Instructions for Pumping System Model PS-90
Standard Operating and Maintenance Instructions for Pumping System Model PS-90 High Pressure Equipment Company 2955 West 17th Street, Suite 6 PO Box 8248 Erie, PA 16505 USA 814-838-2028 (phone) 814-838-6075
More informationInnovative cap to reduce the noise raised by bubbling activity drainage working (vent close)
CHEST DRAINAGE CHEST DRAINAGE WITH AIR LEAK METER AVAILABLE SINGLE AND DUAL COLLECTION Suction control knob to guarantee convenient suction regulation Positive valve Sliding clamp plate (manual discharge
More informationPneumatic high-pressure controller Model CPC7000
Calibration technology Pneumatic high-pressure controller Model CPC7000 WIKA data sheet CT 27.63 Applications Automotive and avionics industry Industry (laboratory, workshop and production) Transmitter
More information829S1 Series Flexflo Pilot
REDQ Regulators The Model 829S1 Provides Versatile Pressure Regulation At An Economical Price. The Model 829S1 Flexflo Pilot is a reversible pressure control regulator (seat & nozzle) that is used in conjunction
More informationHigh-Throughput. Faster, Better 96 & 384-Well Pipetting Ultra Efficient and Extremely Versatile
High-Throughput Rainin BenchSmart 96 Automated Aspiration/Dispense Multi-dispense Interchangeable Heads Four Trays, Small Footprint Outstanding Speed & Versatility Faster, Better 96 & 384-Well Pipetting
More informationThe HumiPyc - Model 1 - Gas Pycnometer; Density, Moisture, Permeation Analyzer; RH sensor Calibrator
The HumiPyc - Model 1 - Gas Pycnometer; Density, Moisture, Permeation Analyzer; RH sensor Calibrator Designed, built, and supported by InstruQuest Inc. Temperature controlled, multi-technique volumetric
More informationPneumatic high-pressure controller Model CPC7000
Calibration technology Pneumatic high-pressure controller Model CPC7000 WIKA data sheet CT 27.63 Applications Healthcare and avionics industry Industry (laboratory, workshop and production) Transmitter
More informationShellPa. Standard Mechanical Cell Stretch System Model No: NNMS Serial #: User Manual
ShellPa Standard Mechanical Cell Stretch System Model No: NNMS Serial #: User Manual To operate the system properly and safely, read the manual before using ShellPa. This system is not a medical device.
More informationChlorinator MODEL MK-I
Chlorinator MODEL MK-I The New model MK- I is semi automatic gas type. Vacuum operated Solution feed Chlorinator designed to provide a continues & measured quantity of gas while in operation. It is suitable
More informationVacuum. Dry Turbo Pumping Stations. Roughing Pumps for 1 K Helium Pots and Lambda Refrigerators. Hermetically Sealed Pumps for He3 Recirculation
Cryogenics Vacuum Dry Turbo Pumping Stations Roughing Pumps for 1 K Helium Pots and Lambda Refrigerators Hermetically Sealed Pumps for He3 Recirculation Oils, Filters and Traps Valves, Fittings and Adaptors
More informationMARITIME PROTECTION NITROGEN SYSTEM
MARITIME PROTECTION NITROGEN SYSTEM WHEN SIZE AND RELIABILITY MATTERS Survitec is proud to present the re-engineered Maritime Protection nitrogen system, fi rst introduced in 1984. NITROGEN SYSTEMS are
More informationThe HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.
The HumiSys RH Generator Designed, built, and supported by InstruQuest Inc. Versatile Relative Humidity Generation and Multi-Sensor System The new HumiSys with single or dual RH probes capabilities is
More informationHydraulic hand spindle pump Models CPP1000-M, CPP1000-L
Calibration Hydraulic hand spindle pump Models CPP1000-M, CPP1000-L WIKA data sheet CT 91.05 for further approvals see page 2 Applications Calibration service companies and service industry Calibrations
More informationBS ml Bottle Sampling Unit
BS500 500ml Bottle Sampling Unit User Guide www.mpfiltri.co.uk 200.307-EN Covers Model Numbers BS500 SAFETY WARNING Hydraulic systems contain dangerous fluids at high pressures and temperatures. Installation,
More informationUTEX INDUSTRIES, INC.
UTEX INDUSTRIES, INC. C A R T R I D G E S E A L Externally located springs are virtually non-clogging Visible drive disc indicates face wear Setting clip removal unnecessary saving installation time Single-piece
More informationDIVATOR THE COMPLETE DIVING SYSTEM INTERSPIRO PRODUCT CATALOG
DIVATOR THE COMPLETE DIVING SYSTEM INTERSPIRO PRODUCT CATALOG 2009 Interspiro AB, Sweden. This publication contains or refers to proprietary information which is protected by copyright. All rights are
More informationEquipment and Accessories. ROMIL LiQuiSure. Designed for High Purity Containment & Dispensing PURE CHEMISTRY
Designed for High Purity Containment & Dispensing To maintain the high purity of ROMIL products during use and handling, we have developed a special range of equipment and accessories under the LiQuiSure
More information11 Air ends 12 Motor 13 Belt driven. 1. ELECTRONIC REGULATION The ES4000 is a control system, designed for medium and high power compressors.
Infinity CSC & CSD Rotary Screw Compressor Range Infinity CSC/CSD compressors are a compact, easy to install range, offering belt or gear driven, fixed or variable speed models. Requiring minimal maintenance,
More informationPTC INSTRUMENTS 2301 Federal Ave Los Angeles CA Phone: Model 500 Automatic Operating Stand Type 3
The Model 500 automatic operating stand provides constant load, controlled rate-of-descent, and application velocity, through a geared electric motor and braking mechanism that alternately lowers the durometer
More informationUnit shown in luffer configuration
Transport complete crane with base section, drums with rope and self assembly device, less counterweights at under 100,000 lbs (45 360 kg) Rated capacity limiter with full color graphic display Powerful
More informationEmergency Transport and Ventilation
Emergency Transport and Ventilation When you get a call and the patient is not breathing, are you and your equipment ready? Can you make the difference? Pneupac portable gas powered ventilators (PGPVs)
More informationRARS5000 AIR BODY SAW OWNER S OPERATING MANUAL
RARS5000 AIR BODY SAW OWNER S OPERATING MANUAL DESCRIPTION 1. No mar 2. No mar tip 3. Housing grip 4. Trigger 5. Air inlet 6. Air inlet plug 7. Plastic board Important! It is essential that you read the
More informationProtec P3000 (XL) Helium Sniffer Leak Detector
Protec P3000 (XL) Helium Sniffer Leak Detector AC C U R AT E, R E L I A B L E L E A K DETECTION AT A DISTANCE Sniffer leak detection you can rely on INFICON Protec P3000 and Protec P3000XL Helium Sniffer
More informationINSTRUCTIONS: CHEMICAL ANALYSIS OF ACTIVE SULFIDES IN OIL-BASED DRILLING FLUID
OFI Testing Equipment Chemical Analysis of Active Sulfides Instructions Page 1 of 4 INSTRUCTIONS: CHEMICAL ANALYSIS OF ACTIVE SULFIDES IN OIL-BASED DRILLING FLUID DESCRIPTION: 1. The Garrett Gas Train
More informationThe HumiPyc ( Model 2) - Gas Pycnometer; Density, Moisture, Permeation Analyzer; Filter Integrity Tester; RH sensor Calibrator
The HumiPyc ( Model 2) - Gas Pycnometer; Density, Moisture, Permeation Analyzer; Filter Integrity Tester; RH sensor Calibrator Designed, built, and supported by InstruQuest Inc. Universal pycnometer, no
More informationHOW WISE TECHNOLOGY WORKS INFICON Protec P3000 sensor powered by Wise Technology, consists of an evacuated gas cell covered by a quartz membrane.
EASY AND COMFORTABLE TO USE FOR FOOLPROOF OPERATION After the initial setup, there is no need to access the base unit, which frees the operator to concentrate on the sniffing process. All relevant messages
More informationHeavy-duty power for the most demanding jobs
110-ton (99.97 mt) Lattice Boom Crawler Crane Heavy-duty power for the most demanding jobs Transport complete crane with base section, drums with rope and self assembly device, less counterweights at under
More informationDesign. Pompetravaini-NSB API SB Liquid Ring Compressor for Gas Processing. Working Principle
SB Pompetravaini-NSB API SB Liquid Ring Compressor for Gas Processing A family of API liquid ring compressors has been developed and has been in the market for nearly a decade, they are specifically made
More informationAllspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW. Tel +44 (0)
Allspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW Tel +44 (0)1254 615100 www.allspeeds.co.uk SOFT LINE CUTTER SL55 PRODUCT CODE No. 980504 INSTRUCTIONS FOR INSTALLATION,
More informationKAYDON RING & SEAL, INC.
KAYDON RING & SEAL, INC. K-DGS Series Dry Gas Seals KAYDON K-DGS Dry Gas Seals K-DGS Configurations Single Seal (K-DGS) Compact and economical, the single seal configuration is recommended for non-toxic
More informationThe NAMIC Dream Kit. Single Operator Control. Reduce Contrast Waste. Less Force to Inject. Compensator * Manifold. How the Compensator Manifold Works:
Dream Kit The NAMIC Dream Kit Single Operator Control. Reduce Contrast Waste. Less Force to Inject. For more than 40 years, NAMIC * Fluid Management products have been providing cardiologists, technicians
More informationP3000 Series. Pneumatic Deadweight Testers Model P3000. Technical Data. Features
P3000 Series Pneumatic Deadweight Testers P3000 Technical Data Features Pressure ranges from Vacuum through 2 000 psi (140 bar) Accuracy better than 0.015 % of reading. (Increased accuracy option of 0.008
More informationUltrasonic baths. XUB range of digital ultrasonic baths. XUBA range of analogue ultrasonic baths. Digitally controlled range with a choice of 5 baths
7 Ultrasonic baths XUB range of digital ultrasonic baths Digitally controlled range with a choice of 5 baths XUBA range of analogue ultrasonic baths Entry level baths with analogue controls Ultrasonic
More informationUnisys. Imagine it. Done. c Consulting. c Systems Integration. c Outsourcing. c Infrastructure. c Server Technology. Unisys NDP 30 and NDP 110
Unisys NDP 30 and NDP 110 The modular document processing system with the flexibility to meet your requirements. RELIABLE CHECK PROCESSING SOLUTIONS. Unisys NDP 30 and NDP 110 Complete Document Processing.
More informationYour local gas generation partner. Precision series Modular gas generation solution for GC.
Your local gas generation partner Precision series Modular gas generation solution for GC www.peakscientific.com Perform with Precision Specifically designed and engineered for GC laboratory applications,
More informationAn intuitive and innovative answer to your anaesthesia challenges
An intuitive and innovative answer to your anaesthesia challenges Dameca AX500 anaesthesia machine Meeting your needs today and tomorrow As an expert in anaesthesia care, you are looking to continuously
More informationRuskinn Hypoxia and Anoxia Workstations. innovation in incubation
Ruskinn Hypoxia and Anoxia Workstations The Ruskinn range of hypoxia workstations has been designed to replicate low oxygen in vivo physiology providing the ideal research platform for cell biologists
More informationAccurate, easy to use and reliable: Easy to use control panel. Clear, backlit LCD display: Quick connect spindles:
Elcometer 2300 Rotational Viscometers The Elcometer 2300 range of rotational viscometers measures the viscosity of liquids in accordance with several standards. Using a rotational viscometer, the properties
More informationDisplacement 12, , Maximum flow rate (at 1450 rpm) bar.
00/07 ED PVD VARIABLE DISPLACEMENT VANE PUMPS SERIES 0 OPERATING PRINCIPLE The PVD pumps are variable displacement vane pumps with a mechanical type of pressure compensator. They allow instantaneous adjustment
More informationMinipuls evolution fitted with three 4-channel Medium Flow pump heads. one 4-channel Medium Flow pump head and one 2-channel High Flow pump head
The Minipuls evolution offers enhanced performances for applications such as : > Perfusion chamber > Bioreactor feeding > Purification column > Animal perfusion > LPLC > Media filling > Transfer of viscous,
More informationPrecision Rotary Airlocks and Diverter Valves
Precision Rotary Airlocks and Diverter Valves Utilizing over 40 Years of Mac Process Bulk Material Conveying Technology Airlocks and Diverters Schenck Process offers a wide range of airlocks and diverter
More informationHumiSys HF High Flow RH Generator
HumiSys HF High Flow RH Generator Designed, built, and supported by InstruQuest Inc. Versatile Relative Humidity Generation and Multi-Sensor System The HumiSys HF is a high flow version of the previously
More informationInFlow Modular perfusion bioreactor
InFlow is an incubator compatible, modular bioreactor for the controlled, bidirectional and interstitial perfusion of up to 9 cell seeded scaffolds with culture medium. InFlow is ideal for general purpose
More informationNarkomed MRI-2. A perfect fit for the MRI environment. Because you care. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care
Narkomed MRI-2 A perfect fit for the MRI environment Emergency Care Perioperative Care Critical Care Perinatal Care Home Care Because you care The complete anesthesia solution for the MRI environment A
More informationAir screwdrivers CSEZ
Air screwdrivers CSEZ Faster, shorter, more accurate Air screwdrivers CSEZ Ideal for some tightening operations on enamelled or painted components, a greater tightening speed was requested (about 2000
More informationPicus NxT Electronic Pipettes Ergonomic, Efficient, & Safe
Picus NxT Electronic Pipettes Ergonomic, Efficient, & Safe Picus NxT Electronic Pipettes Excel in Ergonomics, Efficiency, and Safety Are you looking for the following qualities in a pipette and are not
More informationTTS-800 GOLF ROTORS. Best-in-Class Irrigation Solutions for Every Course. GOLF IRRIGATION Built on Innovation. hunterindustries.
TTS-800 GOLF ROTORS Best-in-Class Irrigation Solutions for Every Course GOLF IRRIGATION Highlands Falls Country Club Highlands, North Carolina A NEW ERA OF Golf Course Irrigation Efficiency White Horse
More informationCAPITAL CONTROLS SERIES NXT3000
CAPITAL CONTROLS SERIES NXT3000 Modular design gas feed system with self contained automatic switchover capability. The Series NXT3000 Gas Feed System is a family of vacuumoperated, solution-feed gas dispensing
More informationInflatable Packer Single & Double. Single & Double Packer Dimension. Wireline Packer. Water Testing Packer (WTP) Packer
Inflatable Packer Single & Double Single & Double Packer Dimension Wireline Packer Water Testing Packer (WTP) Packer Packer Working Pressure & Depth Chart Packer Water Hand Pump Packer Air Driven Pump
More informationOsborne Engineering Limited. OEJ Equalised thrust bearing internals
Osborne Engineering Limited OEJ Equalised thrust bearing internals General Description The Osborne Equalised J style thrust bearing assembly operates by generating and maintaining a substantial oil film
More informationCapital Controls Series NXT3000 Modular design gas feed system with self-contained automatic switchover capability.
Capital Controls Series NXT3000 Modular design gas feed system with self-contained automatic switchover capability. The Series NXT3000 Gas Feed System is a family of vacuum-operated, solution-feed gas
More informationKMT Waterjet Systems Inc.
Advancing Waterjet Technology Worldwide Sales and Support Network Making Waterjet Systems Easier to Use, with Greater Reliability ISO 9001:2000 Certification; CSA and CE Certified Trained, Certified Technicians
More informationVACUUM REGULATORS CONTENTS
CAD drawing data catalog is available. ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS CONTENTS Small Regulators Features 759 Specifications, Order Codes, Flow Rate
More informationWORKHOLDING APPLICATION BOOKLET
WORKHOLDING APPLICATION BOOKLET Applications and advantages of using minibooster hydraulic pressure intensifiers MINIMUM SIZE MAXIMUM POWER B-GB Workholding 2018.04 1 of 20 2 of 20 B-GB Workholding 2018.04
More informationPowermax machine-side reference guide For mechanized applications with Powermax1000, Powermax1250 and Powermax1650
Powermax machine-side reference guide For mechanized applications with Powermax1000, Powermax1250 and Powermax1650 This Powermax machine-side reference guide is a supplement to your Operator Manual and
More informationHospital and Transport for Controlled Breathing
Hospital and Transport for led Breathing When transporting a critically ill patient you need a ventilator that can go anywhere in any situation. Smiths Medical Pneupac small portable gas powered ventilators
More informationAUTOMATIC HOSE TEST UNIT, TYPE SPU
VALVES AND FITTINGS UP TO 14,000 BAR TEST AND CONTROL EQUIPMENT H IGH PRESSURE TECHNOLOGY AUTOMATIC HOSE TEST UNIT, TYPE SPU Pressure range from 1 up to 10,000 bar User-friendly touch panel operation HIGH-PRESSURE
More informationAir Amplifiers & SYSTEMS
Air Amplifiers & SYSTEMS We Accept VISA, MasterCard and American Express Air Amplifiers Point-of-Use Air Solutions Maximator air amplifiers are designed to boost plant air pressure or increase the supply
More informationTHE GOAT AND SHEEP RANGE
INNOVATIVE AND CUSTOMISABLE SOLUTIONS THE GOAT AND SHEEP RANGE MILKING OUTSIDE THE FLOCK FROM SMALL TO LARGE DAIRY FARMS, MILKLINE IS ABLE TO FULFIL THE NEEDS OF ALL FARMERS AND SUPPORT THEM IN THEIR
More informationOPERATION OF THE DIMPLER
OPERATION OF THE DIMPLER After thinning your sample to ~80 μm you can now do a dimpling process to thin the center up to 10 μm. When you walk in and use the DIMPLER it should already be calibrated and
More informationKEYSTONE. A C E C O E n v i r o n m e n t a l C o m p a n y. Bulletin 10-B
KEYSTONE Filtration Solutions A C E C O E n v i r o n m e n t a l C o m p a n y Bulletin 10-B Standard Housings The 11N, 21N and 23N filter housings are tested and certified by NSF International under
More informationRMG 5020 Gas Pressure Regulator Enabling Dependable Gas Operations
RMG 5020 Gas Pressure Regulator Enabling Dependable Gas Operations Proven Technology. Superior Performance. Today s natural gas industry has a growing demand for operational excellence. Pilot-operated
More informationDISSOLUTION TEST FOR SOLID DOSAGE FORMS
Seite 1 von 15 01/2010:20903 corrected 6.8 2.9.3. DISSOLUTION TEST FOR SOLID DOSAGE FORMS This test is provided to determine compliance with the dissolution requirements for solid dosage forms administered
More informationBASIC Z-STACK AND TIME SERIES SCAN ON THE ZEISS LIGHTSHEET Z. 1
BASIC Z-STACK AND TIME SERIES SCAN ON THE ZEISS LIGHTSHEET Z. 1 The front door of the main body of the instrument may be open when you arrive. Take the sample chamber and slide it into position with the
More information