The Original Simply The Best. Dredging Technology with Körting Ejectors

Size: px
Start display at page:

Download "The Original Simply The Best. Dredging Technology with Körting Ejectors"

Transcription

1 Dredging Technology with Körting Ejectors

2 Ejectors on Assembly- and Drilling Platforms The English terms ejector, jet pump or eductor all describe the same ejector technology, as does the standard term Strahlpumpe in the German language area. They are transport systems in which the drive is provided by a drive medium. Water or compressed air are generally employed in ship's technology, depending on the planned application case. By means of the motive medium a secondary flow this can be liquids, gases or vapours, solids or a mixture thereof - can be sucked in and delivered to a higher pressure level together with the motive medium. With this operating method ejector technology covers practically the whole field of pumping technology, also known from the mechanical systems. So you can find ejectors just for transporting of liquids and equally as venting equipment, compressors, vacuum ejectors, dosing systems or as mixing equipment. Körting Hannover AG, located in Hannover since its founding in 1871, is known as the world s leading manufacturer of this type of ejector technology. Based on the developments made by Ernst Körting the company s system technology stands for a broad spectrum of applications, also in the field of marine engineering. This covers the very wellknown bilge ejectors and their outstanding characteristics with regard to reliability against dry-running, selfpriming operating method and long-term maintenancefree service life as well as the central evacuating equipment for non selfpriming mechanical feed pumps. For example, a further application case may be found in the generation of operating vacuum and the suction removal of lye solutions at thermal seawater evaporators. The above given application cases and system characteristics stand here for a multitude of employment possibilities on a ship without describing these in greater detail here.

3 Degassing Systems One recent development, also based on this technology, are the so-called degassing systems for use on board dredgers especially the so-called hopper dredgers. Should these ships dredge out sediments containing gas pockets - this happens quite often when increasing the depth of shipping lanes or reclaiming land - then these gas pockets can become dangerous in two different ways. First of all though, the technical aspect is the predominant point but in addition to this, those aspects dealing with the environmental point of view are also becoming more and more important. The technical aspect refers to the possible rupturing of the suction flow at a mechanical dredger pump. This is accompanied by the so-called water hammer which caused by the liberated forces, can lead to a total destruction of the mechanical dredger pump. Such damages could lead to considerable material expenses. In addition to this, there would be a certain period of outage time for necessary repairs which again would lead to further costs, e.g. contractual penalty payments to the customer. In less critical cases, gas contained in the dredger pump's suction flow can lead to a continued rupturing of the suction flow and inevitably to repeated start-up actions each time this happens. In extreme cases, the removal of dredged material with a high gas content just cannot be accomplished without degassing equipment. A solution to this problem may be found in freeing the extraction flow sucked through the dredger pump of all incorporated harmful gas pockets before it enters the dredger pump casing. This calls for an exceptionally robust type of vacuum system as the process takes place under relatively harsh operating conditions and the intake gas flow can be mixed with water and solids. Usually this duty is fulfilled by the exceedingly reliable and practically maintenance-free operating water jet vacuum ejectors. The previously mentioned environmental aspect for utilising degassing systems has resulted from the fact that a non-degassed excavated flow is loaded with a higher portion of secondary water. Generally speaking, due to its high pollutants contents this water may not be passed out via the overflow. So the dredger's cargo holds are filled with secondary water which reduces the dredger's performance by diminishing its loading capacity and thereby increasing the operating costs. A further undesirable subsidiary effect may be found in the high strains put on the irrigation fields by this secondary water. All efforts are being made to relieve the irrigation fields of avoidable ballast as only a restricted field area is available for dumping purposes. The degassing technology offers an appropriate possibility.

4 Advantages The loading diagram in Fig. 4 clearly shows which advantages may be gained by using a degassing equipment with the resulting cutback of secondary water flow. Degassing equipment was utilised from the 8th journey out onwards. On using the degassing equipment it could be seen that there was an immediate increase in the portion of solid matter and that the transport behaviour became visibly smoother. The measuring data was collected by the dredging contractors Johann Bunte Bauunternehmung GmbH during operation of their dredger F. Volker SR in Leer. These measuring data are of special interest as they show the very rare situation in the dredging operations were carried out in the the same area with the same dredger. So for evaluation constant conditions can be assumed. The only deviation consists of the changeover to a degassing system based on the water jet vacuum technology developed by Körting Hannover AG. After modification the same dredger achieved an up to 100 % improved loading result in comparison to an operating mode without a degassing system. Dredging characteristics m Journeys solid material mixed liquid & solid material total load Figure 4

5 Design In the most simplified form such a degassing equipment consists of a single conventional- type water jet vacuum ejector. The constructional size of the required ejector for the degassing process will increase in relation to the large suction ratings of today's dredger systems. As water jet vacuum ejectors achieve their optimum performance when they are installed in a vertical position, space problems soon occur in the shipbuilding industry when constructional sizes reach more than 3 m in length. One solution for this problem can be found in the parallel connection of smaller ejectors. This type of installation also offers the advantage of being able to switch individual ejectors on and off and so adjust the degassing performance to the actual operating conditions. However, this installation form can also be disadvantageous because it is necessary to mount a greater number of ejectors. This can result in quite considerable installation expenses with regard to necessary pipeline construction. The installation of so-called multi-ejectors (bundled ejectors) can help to reduce these cost factors and simultaneously reduce the amount of installation space required for the degassing system. With this constructional form it is quite usual to have several individual ejectors - up to approx. 30 units - bundled together in a common casing. Each bundle of ejectors therefore has just one suction- and one motive connection. So the necessary expenditure for piping as required by conventional parallel- connected individual ejectors can be reduced to a considerable extent.

6 Suction power adjustment The last remaining question concerns the performance adjustment of such a water jet vacuum ejector unit to the differing gas quantities which usually occur in the dredger flow. Even this problem can be solved by connecting several of these bundled ejectors in parallel in the usual large installations. A reduction in performance can, however, only be achieved within the range of the executed number of bundles as each bundle of ejectors is to be considered as an individual ejector unit. As water jet vacuum ejectors have a performance curve which can be influenced by the supplied motive pressure this too offers a further possibility of adjusting the suction performance to the actual composition of the dredged material requiring degassing.

7 Figure 6 shows a bundle of ejectors in the process of being installed. The increased number of mixing tubes for the installed water jet vacuum ejectors can be clearly seen. In this actual case the whole system consists of 3 parallel connected bundled ejectors and was executed for use on board the hopper dredger Alexander von Humboldt. The necessary supplementary component parts such as hot well, piping, fittings etc. were planned in collaboration with Körting Hannover AG but were actually manufactured by the shipyard. With this type of construction there is the possibility of separating out solids entrained in the suction flow to prevent them from entering - and therefore jamming - the bundled ejectors. This is effected quite simply by the gravity separation method. Solids and entrained water removed from the flow are collected in a buffer tank and are pumped out when required by means of a special liquid jet solids ejector. Figure 6 M-type ejector

Körting Liquid Jet Vacuum Ejectors

Körting Liquid Jet Vacuum Ejectors Körting iquid Jet Vacuum Ejectors Körting iquid Jet Vacuum Ejectors iquid jet vacuum ejectors convey and compress gases or vapours with the aid of a liquid motive fluid. During this action vapours - corresponding

More information

Training Title IDENTIFY OPERATIONAL UPSETS, REVIEW & VALIDATE IN OIL & CHEMICAL PLANTS

Training Title IDENTIFY OPERATIONAL UPSETS, REVIEW & VALIDATE IN OIL & CHEMICAL PLANTS Training Title IDENTIFY OPERATIONAL UPSETS, REVIEW & VALIDATE IN OIL & CHEMICAL PLANTS Training Duration 5 days Training Venue and Dates Identify Operational Upsets, Review & Validate in Oil & Chemical

More information

Processing instructions V REFRAJET Addmix nozzle

Processing instructions V REFRAJET Addmix nozzle Refratechnik Steel GmbH Schiessstrasse 58 40549 Düsseldorf Germany Phone: +49 211 5858 0 Fax: +49 211 5858 49 steel@refra.com www.refra.com Processing instructions V 3.6.1 Note: Please read the product

More information

Digester Processes. 1. Raw Sludge Pumping System

Digester Processes. 1. Raw Sludge Pumping System Digester Processes 1. Raw Sludge Pumping System Removes accumulated sludge from the primary clarifiers, pumped through 1 of 2 pipes either 150 or 200mm in diameter (Fig. 1.1). Fig 1.1 Pipes feeding Digesters

More information

Caltec. The world leader in Surface Jet Pump (SJP) and compact separation systems for upstream oil and gas production enhancement

Caltec.   The world leader in Surface Jet Pump (SJP) and compact separation systems for upstream oil and gas production enhancement Caltec brings simple passive technology that enables oil and gas operators to harness the kinetic energy of the production process to enhance their production, extending economic field life and reducing

More information

Multiple Pressure Booster Systems With Variable Speed Controller Type BL

Multiple Pressure Booster Systems With Variable Speed Controller Type BL Multiple Pressure Booster Systems With Variable Speed Controller Type BL General Characteristics - Single or multistage pumps - Horizontal or vertical mounting - Total head 30m ~ 250m - Material construction:

More information

ejector solutions Flare Gas Recovery & Zero Flare Solutions

ejector solutions Flare Gas Recovery & Zero Flare Solutions ejector solutions Flare Gas Recovery & Zero Flare Solutions Time to change. Traditionally, in the Oil & Gas industry, waste and surplus gas has been disposed of by flaring to atmosphere. Today this process

More information

How to Select High Pressure and Gas Bypass

How to Select High Pressure and Gas Bypass Application Guide How to Select High Pressure and Gas Bypass Valves This Application Guide provides a theoretical explanation of how to select the optimum high pressure valves and gas bypass valves for

More information

Liquid ring vacuum pumps single-stage

Liquid ring vacuum pumps single-stage Liquid ring vacuum pumps single-stage LPH 40106, LPH 40411, LPH 40516 Pressure range: Suction volume flow: 150 to 1013 mbar 50 to 270 m³/h CONSTRUCTION TYPE Sterling SIHI liquid ring vacuum pumps are displacement

More information

Dredging Keeping Our Underwater Highways Open

Dredging Keeping Our Underwater Highways Open Dredging Keeping Our Underwater Highways Open Sedimentation Material that falls to the bottom of a liquid is called sediment. If enough sediment deposits to build a shallow spot on the river or ocean bottom,

More information

Liquid ring vacuum pumps in compact design

Liquid ring vacuum pumps in compact design Liquid ring vacuum pumps in compact design LEM 25, LEM 5 Pressure range: Suction volume flow: 33 to 113 mbar 4 to 6 m³/h CONSTRUCTION SIHI liquid ring vacuum pumps are displacement pumps of uncomplicated

More information

Module No. # 01 Lecture No. # 6.2 HAZOP (continued)

Module No. # 01 Lecture No. # 6.2 HAZOP (continued) Health, Safety and Environmental Management in Petroleum and Offshore Engineering Prof. Srinivasan Chandrasekaran Department of Ocean Engineering Indian Institute Of Technology, Madras Module No. # 01

More information

Compressors. Basic Classification and design overview

Compressors. Basic Classification and design overview Compressors Basic Classification and design overview What are compressors? Compressors are mechanical devices that compresses gases. It is widely used in industries and has various applications How they

More information

APPENDIX 4 STANDARD FORMAT FOR THE PROCEDURES AND ARRANGEMENTS MANUAL

APPENDIX 4 STANDARD FORMAT FOR THE PROCEDURES AND ARRANGEMENTS MANUAL Page 42 APPENDIX 4 STANDARD FORMAT FOR THE PROCEDURES AND ARRANGEMENTS MANUAL Note 1: Note 2: The format consists of a standardized introduction and index of the leading paragraphs to each section. This

More information

Chlorinator MODEL MK-I

Chlorinator MODEL MK-I Chlorinator MODEL MK-I The New model MK- I is semi automatic gas type. Vacuum operated Solution feed Chlorinator designed to provide a continues & measured quantity of gas while in operation. It is suitable

More information

Total s Golden rules

Total s Golden rules Total s Golden rules Golden rule No. 12: Simultaneous operations or co-activities This presentation resumes in part the document that won an award at the 2011 World Day for Safety at work, written by:

More information

Liquid ring vacuum pumps in compact design

Liquid ring vacuum pumps in compact design Liquid ring vacuum pumps in compact design, Pressure range: Suction volume flow: 33 to 113 mbar 3 to 58 m³/h CONSTRUCTION TYPE SIHI liquid ring vacuum pumps are displacement pumps of uncomplicated and

More information

SMART Explosion. Efficient Boiler Cleaning with Explosion Generators

SMART Explosion. Efficient Boiler Cleaning with Explosion Generators SMART Explosion Efficient Boiler Cleaning with Explosion Generators Problem and Solution The use of solid fuels, such as coal, waste or biomass, is liable to intense fouling of the steam generator heating

More information

Removing nitrogen. Nitrogen rejection applications can be divided into two categories

Removing nitrogen. Nitrogen rejection applications can be divided into two categories Removing nitrogen Doug MacKenzie, Ilie Cheta and Darryl Burns, Gas Liquids Engineering, Canada, present a comparative study of four nitrogen removal processes. Nitrogen rejection applications can be divided

More information

FLUID POWER FLUID POWER EQUIPMENT TUTORIAL ACCUMULATORS. This work covers part of outcome 2 of the Edexcel standard module:

FLUID POWER FLUID POWER EQUIPMENT TUTORIAL ACCUMULATORS. This work covers part of outcome 2 of the Edexcel standard module: FLUID POWER FLUID POWER EQUIPMENT TUTORIAL ACCUMULATORS This work covers part of outcome 2 of the Edexcel standard module: UNIT 21746P APPLIED PNEUMATICS AND HYDRAULICS The material needed for outcome

More information

E 158 E 198 E 248. Tank top mounting Connection up to G11 / 4 Nominal flow rate up to 250 l/min e d

E 158 E 198 E 248. Tank top mounting Connection up to G11 / 4 Nominal flow rate up to 250 l/min e d R e t u r n - S u c t i o n F i l t e rs E 158 E 198 E 248 Tank top mounting Connection up to G11 / 4 Nominal flow rate up to 250 l/min 20.90-5e 0.0-2d D e s c r i p t i o n Application For operation in

More information

"INOGATE Technical Secretariat & Integrated Programme in support of the Baku Initiative and the Eastern Partnership energy objectives" Project

INOGATE Technical Secretariat & Integrated Programme in support of the Baku Initiative and the Eastern Partnership energy objectives Project "INOGATE Technical Secretariat & Integrated Programme in support of the Baku Initiative and the Eastern Partnership energy objectives" Project B U I L D I N G P A R T N E R S H I P S F O R E N E R G Y

More information

Liquid ring compressors

Liquid ring compressors Liquid ring compressors KPH 85220, KPH 85227 Compression pressures: Suction volume flow: 2 to 7 bar 940 to 1450 m³/h CONSTRUCTION TYPE Sterling SIHI liquid ring compressors are displacement compressors

More information

Unit 24: Applications of Pneumatics and Hydraulics

Unit 24: Applications of Pneumatics and Hydraulics Unit 24: Applications of Pneumatics and Hydraulics Unit code: J/601/1496 QCF level: 4 Credit value: 15 OUTCOME 2 TUTORIAL 9 ACCUMULATORS The material needed for outcome 2 is very extensive so there are

More information

High-performance submersible pressure transmitter For level measurement Model LH-10

High-performance submersible pressure transmitter For level measurement Model LH-10 Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-10 WIKA data sheet PE 81.09 Applications Level measurement in rivers and lakes Deep well

More information

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS Annex 3, page 2 ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS The text of existing chapter 15 is replaced by the following: "1 Application This

More information

Courses of Instruction: Controlling and Monitoring of Pipelines

Courses of Instruction: Controlling and Monitoring of Pipelines Courses of Instruction: Controlling and Monitoring of Pipelines Date December 2010 Dr. Peter Eschenbacher Partner Angergraben 4 85250 Altomünster Germany Tel. +49-(0)8254 / 99 69 57 Fax +49-(0)8254 / 99

More information

ANNEX 5 RESOLUTION MEPC.127(53) Adopted on 22 July 2005 GUIDELINES FOR BALLAST WATER MANAGEMENT AND DEVELOPMENT OF BALLAST WATER MANAGEMENT PLANS (G4)

ANNEX 5 RESOLUTION MEPC.127(53) Adopted on 22 July 2005 GUIDELINES FOR BALLAST WATER MANAGEMENT AND DEVELOPMENT OF BALLAST WATER MANAGEMENT PLANS (G4) RESOLUTION MEPC.127(53) Adopted on 22 July 2005 GUIDELINES FOR BALLAST WATER MANAGEMENT AND DEVELOPMENT OF BALLAST WATER MANAGEMENT PLANS (G4) THE MARINE ENVIRONMENT PROTECTION COMMITTEE, RECALLING Article

More information

HANDBOOK. Squeeze Off Unit SOU 400. Please refer any queries to:

HANDBOOK. Squeeze Off Unit SOU 400. Please refer any queries to: HANDBOOK Squeeze Off Unit SOU 400 Please refer any queries to: Hy Ram Engineering Co Ltd Pelham Street Mansfield Nottinghamshire NG18 2EY Telephone No: (01623) 422982 Please note all queries should state

More information

DEALING WITH ESP ASH EVACUATION PROBLEMS EXPERIENCES AT DADRI & TALCHER KANIHA. Ujjwal Chowdhury KD Yadav LD Sahoo

DEALING WITH ESP ASH EVACUATION PROBLEMS EXPERIENCES AT DADRI & TALCHER KANIHA. Ujjwal Chowdhury KD Yadav LD Sahoo DEALING WITH ESP ASH EVACUATION PROBLEMS EXPERIENCES AT DADRI & TALCHER KANIHA Ujjwal Chowdhury KD Yadav LD Sahoo Typical Ash Distribution In a Boiler Typical Dry Fly Ash Handling Arrangement at a Power

More information

Advanced Technology of Thruster Seal

Advanced Technology of Thruster Seal Author s Name Name of the Paper Session DYNAMIC POSITIONING CONFERENCE September 16-17, 2003 THRUSTERS Mr. Isao Sasada Kobelco Marine Engineering 2-3-1, Shinhama Arai-cho, Takasago, 676-8670, Japan ABSTRACT

More information

SIHI LPH-X - Liquid Ring Compressors

SIHI LPH-X - Liquid Ring Compressors - Liquid Ring Compressors LPH 50523 LPH 60527 Pressure range: Suction volume range: 0.2 to 1.5 bar 260 to 780 m³/h CONSTRUCTION Sterling SIHI liquid ring compressors are displacement compressors with a

More information

Geotech 1.66 Auto-Reclaimer

Geotech 1.66 Auto-Reclaimer Geotech 1.66 Auto-Reclaimer Installation and Operation Rev 9 8/31/06 Part # 16600165 TABLE OF CONTENTS CHAPTER 1: SYSTEM DESCRIPTION... 3 FUNCTION AND THEORY... 3 SYSTEM COMPONENTS... 4 CHAPTER 2: SYSTEM

More information

Geotech 1.66 Auto-Reclaimer Installation and Operation

Geotech 1.66 Auto-Reclaimer Installation and Operation Geotech 1.66 Auto-Reclaimer Installation and Operation Rev 10/19/12 Part # 16600165 TABLE OF CONTENTS CHAPTER 1: SYSTEM DESCRIPTION... 3 FUNCTION AND THEORY... 3 SYSTEM COMPONENTS... 4 CHAPTER 2: SYSTEM

More information

PETROLEUM & GAS PROCESSING TECHNOLOGY (PTT 365) SEPARATION OF PRODUCED FLUID

PETROLEUM & GAS PROCESSING TECHNOLOGY (PTT 365) SEPARATION OF PRODUCED FLUID PETROLEUM & GAS PROCESSING TECHNOLOGY (PTT 365) SEPARATION OF PRODUCED FLUID Miss Nur Izzati Bte Iberahim Introduction Well effluents flowing from producing wells come out in two phases: vapor and liquid

More information

ANNEX 2 RESOLUTION MEPC.124(53) Adopted on 22 July 2005 GUIDELINES FOR BALLAST WATER EXCHANGE (G6) THE MARINE ENVIRONMENT PROTECTION COMMITTEE,

ANNEX 2 RESOLUTION MEPC.124(53) Adopted on 22 July 2005 GUIDELINES FOR BALLAST WATER EXCHANGE (G6) THE MARINE ENVIRONMENT PROTECTION COMMITTEE, Page 1 RESOLUTION MEPC.124(53) Adopted on 22 July 2005 GUIDELINES FOR BALLAST WATER EXCHANGE (G6) THE MARINE ENVIRONMENT PROTECTION COMMITTEE, RECALLING Article 38(a) of the Convention on the International

More information

Ennore Coal Port Project: Port Basin and Entrance Channel

Ennore Coal Port Project: Port Basin and Entrance Channel Ennore Coal Port Project: Port Basin and Entrance Channel André Luypaert Ennore Coal Port Project: Port Basin and Entrance Channel Abstract The Chennai Port on the eastern coast of India is the main port

More information

Liquid ring vacuum pumps in compact design

Liquid ring vacuum pumps in compact design Liquid ring vacuum pumps in compact design LEM 26, LEM 51 Pressure range: Suction volume flow: 33 to 113 mbar 3 to 58 m³/h CONSTRUCTION TYPE SIHI liquid ring vacuum pumps are displacement pumps of uncomplicated

More information

Transient Analyses In Relief Systems

Transient Analyses In Relief Systems Transient Analyses In Relief Systems Dirk Deboer, Brady Haneman and Quoc-Khanh Tran Kaiser Engineers Pty Ltd ABSTRACT Analyses of pressure relief systems are concerned with transient process disturbances

More information

Oxygen Generating Systems Ozone Medical Welding Glassblowing Aquaculture Pulp & Paper Wastewater

Oxygen Generating Systems Ozone Medical Welding Glassblowing Aquaculture Pulp & Paper Wastewater Oxygen Generating Systems General Information Extract oxygen directly from the atmosphere and deliver it to any medical or industrial application with an OGSI oxygen generator. Our standard line of Pressure

More information

THE REPUBLIC OF LIBERIA LIBERIA MARITIME AUTHORITY

THE REPUBLIC OF LIBERIA LIBERIA MARITIME AUTHORITY Office of Deputy Commissioner of Maritime Affairs THE REPUBLIC OF LIBERIA LIBERIA MARITIME AUTHORITY Marine Notice POL-010 Rev. 04/10 TO: SUBJECT: ALL SHIPOWNERS, OPERATORS, MASTERS AND OFFICERS OF MERCHANT

More information

Liquid ring compressors

Liquid ring compressors Liquid ring compressors KPH 95652 Compression pressures: 6 to 12 bar(g) Suction volume flow: 2960 to 3600 m³/h 78 to 174 psig 1742 to 2119 cfm DESIGN TYPE SIHI liquid ring compressors are displacement

More information

OPERATING INSTRUCTIONS MANUAL FOR QACV PNEUMATIC DOSING PUMP

OPERATING INSTRUCTIONS MANUAL FOR QACV PNEUMATIC DOSING PUMP This operating instructions contains safety information that if ignored can endanger life or result in serious injury. They are indicated by this icon. Use of this pump with radioactive chemicals is forbidden!

More information

GLD TM Ballast Water Treatment System

GLD TM Ballast Water Treatment System GLD TM Ballast Water Treatment System APPROVED AMS APPROVED In-tank, in-voyage, inspired The Coldharbour Marine approach to BWT is absolutely unique Who is it for? Coldharbour GLD (Gas Lift Diffusion)

More information

MULTI-STAGE VACUUM GENERATORS - GENERAL INFORMATION

MULTI-STAGE VACUUM GENERATORS - GENERAL INFORMATION MULTI-STAGE VACUUM GENERATORS - GENERAL INFORMATION Our multi-stage vacuum generators produce a maximum vacuum of 90%, equal to a final vacuum level of 100 mbar abs., with different suction capacities.

More information

Free Surface Flow Simulation with ACUSIM in the Water Industry

Free Surface Flow Simulation with ACUSIM in the Water Industry Free Surface Flow Simulation with ACUSIM in the Water Industry Tuan Ta Research Scientist, Innovation, Thames Water Kempton Water Treatment Works, Innovation, Feltham Hill Road, Hanworth, TW13 6XH, UK.

More information

Niltox Breathing Air Purifier Range

Niltox Breathing Air Purifier Range Breathing Air Requirements The main standards affecting breathing air are BSEN529, EN12021 and COSHH. The requirements for a breathing air system are shown in the table opposite and the requirements for

More information

High-performance submersible pressure transmitter For level measurement Model LH-10

High-performance submersible pressure transmitter For level measurement Model LH-10 Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-10 WIKA data sheet PE 81.09 Applications Level measurement in rivers and lakes Deep well

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS MODEL GS2000 / GS2001 OIL-LESS REFRIGERANT RECOVERY UNIT NATIONAL REFRIGERATION PRODUCTS 985 WHEELER WAY LANGHORNE, PA 19047 (215) 638-8909 FAX (215) 638-9270 R01099 GS2000.DOC NRP-OM-GS2000

More information

OIL IN NAVIGABLE WATERS REGULATIONS [L.N. 101 of 1968.] under sections 5 and 7. [22nd April, 1968] [Comrnencernent.]

OIL IN NAVIGABLE WATERS REGULATIONS [L.N. 101 of 1968.] under sections 5 and 7. [22nd April, 1968] [Comrnencernent.] OIL IN NAVIGABLE WATERS REGULATIONS [L.N. 101 of 1968.] under sections 5 and 7 [Comrnencernent.] [22nd April, 1968] 1. Short title and interpretation (1) These Regulations may be cited as the Oil in Navigable

More information

Liquid ring compressor

Liquid ring compressor Liquid ring compressor KLH 47005, KLH 47105 Compression pressures: Suction volume flow: 2 to 11 bar 56 to 65 m³/h CONSTRUCTION TYPE Sterling SIHI liquid ring compressors are displacement compressors of

More information

E 328 E 498 Tank top mounting Connection up to G1½ / -24 SAE and SAE 2 Nominal flow rate up to 600 l/min / gpm

E 328 E 498 Tank top mounting Connection up to G1½ / -24 SAE and SAE 2 Nominal flow rate up to 600 l/min / gpm Return-Suction Filters E 8 E 98 Tank top mounting Connection up to G½ / - SE and SE Nominal flow rate up to 6 l/min / 8. gpm Description pplication For operation in units with hydrostatic drives, when

More information

RESOLUTION MEPC.209(63) Adopted on 2 March GUIDELINES ON DESIGN AND CONSTRUCTION TO FACILITATE SEDIMENT CONTROL ON SHIPS (G12)

RESOLUTION MEPC.209(63) Adopted on 2 March GUIDELINES ON DESIGN AND CONSTRUCTION TO FACILITATE SEDIMENT CONTROL ON SHIPS (G12) Annex 3, page 1 ANNEX 3 THE MARINE ENVIRONMENT PROTECTION COMMITTEE, RECALLING Article 38(a) of the Convention on the International Maritime Organization concerning the functions of the Marine Environment

More information

HANDBOOK. Squeeze Off Unit SOU 250. Please refer any queries to:

HANDBOOK. Squeeze Off Unit SOU 250. Please refer any queries to: HANDBOOK Squeeze Off Unit SOU 250 Please refer any queries to: Hy Ram Engineering Co Ltd Pelham Street Mansfield Nottinghamshire NG18 2EY Telephone No: (01623) 422982 Please note all queries should state

More information

White Paper. Electrical control valve actuators on oil and gas production separators

White Paper. Electrical control valve actuators on oil and gas production separators White Paper Electrical control valve actuators on oil and gas production separators Electrical control valve actuators on oil and gas production separators White Paper 18 th August 2014 Electrical control

More information

Test pumps. Pressure sources. Good reasons for proper and reliable calibration

Test pumps. Pressure sources. Good reasons for proper and reliable calibration Test pumps Pressure is one of the most commonly measured quantities in engineering, which is why exact and reliable pressure measurement is especially important. However, the characteristics of the even

More information

E 328 E 498 Tank top mounting Connection up to G1½ and SAE 2 Nominal flow rate up to 600 l/min

E 328 E 498 Tank top mounting Connection up to G1½ and SAE 2 Nominal flow rate up to 600 l/min Return-Suction Filters E 8 E 98 Tank top mounting Connection up to G½ and SE Nominal flow rate up to 6 l/min Description pplication For operation in units with hydrostatic drives, when the return flow

More information

THE INFLOW OF UNWANTED AIR

THE INFLOW OF UNWANTED AIR IN PRESSURIZED PIPES The main reason for the inflow of air in public water distribution systems is excessive water velocity. Air traveling with water in pressurized pipes can result in high turbulence

More information

COMPRESSED AIR DISTRIBUTION SYSTEMS

COMPRESSED AIR DISTRIBUTION SYSTEMS Series COMPRESSED AIR DISTRIBUTION SYSTEMS 18 DESIGNING AN EFFICIENT COMPRESSED AIR DISTRIBUTION The main source of inefficiencies and problems affecting compressed air distribution systems is often the

More information

7 CARGO AND BALLAST PUMPS 7.1 PUMP THEORY AND CHARACTERISTICS

7 CARGO AND BALLAST PUMPS 7.1 PUMP THEORY AND CHARACTERISTICS 7 CARGO AND BALLAST PUMPS Learning objectives -that the suction action of a pump is really atmospheric pressurepushing the liquid into the inlet side of the pump -how low vapor pressure of the liquid being

More information

GLD TM Ballast Water Treatment System

GLD TM Ballast Water Treatment System GLD TM Ballast Water Treatment System APPROVED AMS APPROVED In-tank, in-voyage, inspired The Coldharbour Marine approach to BWT is absolutely unique Who is it for? Coldharbour GLD (Gas Lift Diffusion)

More information

Impact of Vacuum treatment on DGA Dipl.-Ing. J. Altmann

Impact of Vacuum treatment on DGA Dipl.-Ing. J. Altmann 1 1. Introduction Impact of Vacuum treatment on DGA Dipl.-Ing. J. Altmann State of the art for the diagnosis of undesired changes in the Insulating Systems of oilimmersed transformers is DGA - Dissolved

More information

CONDITIONS OF USE OF THIS REPORT COPYRIGHT NAMIBIAN MARINE PHOSPHATE (PTY) LTD 2014 ALL RIGHTS RESERVED

CONDITIONS OF USE OF THIS REPORT COPYRIGHT NAMIBIAN MARINE PHOSPHATE (PTY) LTD 2014 ALL RIGHTS RESERVED CONDITIONS OF USE OF THIS REPORT COPYRIGHT NAMIBIAN MARINE PHOSPHATE (PTY) LTD 2014 ALL RIGHTS RESERVED. All rights to the intellectual property and/or contents of this document remain vested in Namibian

More information

6-way characterised control valves DN15 / DN 20 / DN 25

6-way characterised control valves DN15 / DN 20 / DN 25 6-way characterised control valves DN15 / DN 20 / DN 25 Table of contents Introduction 2 Project planning 2 Structure of the 6-way characterised control valves 2 Range of use 2 Characteristic curve 3 Flow

More information

Introduction to Pumps

Introduction to Pumps Introduction to Pumps 1 Introduction to Pumps 1.0 INTRODUCTION There are many different types of pump now available for use in pumped fluid systems. A knowledge of these pump types and their performance

More information

Protectingpipelinesfor

Protectingpipelinesfor 24 Protectingpipelinesfor Michael Paulin, Damien Humby and Joseph Cocker, INTECSEA Canada, and Glenn Lanan, INTECSEA Inc., describe the process of trenching for the protection of pipelines in ice environments.

More information

Another convenient term is gauge pressure, which is a pressure measured above barometric pressure.

Another convenient term is gauge pressure, which is a pressure measured above barometric pressure. VACUUM Theory and Applications Vacuum may be defined as the complete emptiness of a given volume. It is impossible to obtain a perfect vacuum, but it is possible to obtain a level of vacuum, defined as

More information

Tradition & Technology

Tradition & Technology Gaterotor Support Gaterotor Single Screw Compressors Design & Operation Bearing Bearings Main Screw Parallex Slide System The VSM Single Screw Compressor has one main rotor and two gaterotors. All bearings

More information

Pipe-Away Pressure Vacuum Vent /Conservation Vent

Pipe-Away Pressure Vacuum Vent /Conservation Vent R R Pressure Vacuum Vent / End of Line Conservation Vent Flame Arrester with Pressure Vacuum Vent Pipe Away Pressure Vacuum Vent / Conservation Vent Vacuum Relief Vent Pressure Emergency Vent Free Vents

More information

Chlorinator. MODEL C-731 (Floor Mounted)

Chlorinator. MODEL C-731 (Floor Mounted) Chlorinator MODEL C-731 (Floor Mounted) CHLOROTECH Model C-731 is the advance technology Chlorinator designed to feed chlorine gas at a controlled rate. The flow rate of gas is maintained by constant positive

More information

SOLAR AUTOMATIC AIR VENTS AND DEAERATORS FOR SOLAR INSTALLATIONS NEW: AUTOCLOSE DOMESTIC COMMERCIAL SPIRO EXCEPTIONAL GUARANTEE

SOLAR AUTOMATIC AIR VENTS AND DEAERATORS FOR SOLAR INSTALLATIONS NEW: AUTOCLOSE DOMESTIC COMMERCIAL SPIRO EXCEPTIONAL GUARANTEE SOLAR AUTOMATIC AIR VENTS AND DEAERATORS FOR SOLAR INSTALLATIONS NEW: AUTOCLOSE OPEN WHEN POSSIBLE CLOSED WHEN NECESSARY No shut-off valves required No risk of boiling dry via the deaerator Always an air-free

More information

ejector solutions Flare Gas Recovery Case Study Major Norwegian Operator, North Sea

ejector solutions Flare Gas Recovery Case Study Major Norwegian Operator, North Sea ejector solutions Flare Gas Recovery Case Study Major Norwegian Operator, North Sea Background Reduction in flaring volumes is a major target for all offshore facilities operating in the Norwegian Continental

More information

ZUERCHER TANK REGULATORS PRINCIPLES OF TANK VENTILATION

ZUERCHER TANK REGULATORS PRINCIPLES OF TANK VENTILATION Why Inertisation (blanketing) of Tanks? General Tank inertisation or blanketing is required in many applications where products or liquids stored in the tank are processed and/or filled into and emptied

More information

OXYGEN and SYSTEM OXY

OXYGEN and SYSTEM OXY OXYGEN and SYSTEM OXY Used to mix the treated liquid with air allowing a high degree of oxygen exchange Particularly indicated for an efficient oxigenation in waste water treatment plant as well as industrial

More information

Heat Pump Connections and Interior Piping

Heat Pump Connections and Interior Piping Job Sheet 3 Heat Pump Connections and Interior Piping OBJECTIVES In this job sheet, you will observe how the presence of air in the ground loop affects the geothermal heat pump performance. You will also

More information

Pressure Systems Safety Regulation

Pressure Systems Safety Regulation Pressure Systems Safety Regulation Introduction This document informs Faculty of the key requirements of the UK and Chinese Pressure Systems Safety regulations. The aim of these regulations is to prevent

More information

Identification and Screening of Scenarios for LOPA. Ken First Dow Chemical Company Midland, MI

Identification and Screening of Scenarios for LOPA. Ken First Dow Chemical Company Midland, MI Identification and Screening of Scenarios for LOPA Ken First Dow Chemical Company Midland, MI 1 Layers of Protection Analysis (LOPA) LOPA is a semi-quantitative tool for analyzing and assessing risk. The

More information

CO 2 and O 2 scrubbers

CO 2 and O 2 scrubbers CO 2 and O 2 scrubbers The CO2 scrubber Fruit breathes : it uses oxygen (O2) and produces carbon dioxide (CO2). If the concentration of carbon dioxide (carbonic acid) gets too high, the quality of the

More information

LP Separator Level Control by Variable Speed and Multi Stage Brine Reinjection Pumps at Kawerau and Nga Awa Purua Geothermal Projects, New Zealand

LP Separator Level Control by Variable Speed and Multi Stage Brine Reinjection Pumps at Kawerau and Nga Awa Purua Geothermal Projects, New Zealand Proceedings World Geothermal Congress 2010 Bali, Indonesia, 25-29 April 2010 LP Separator Level Control by Variable Speed and Multi Stage Brine Reinjection Pumps at Kawerau and Nga Awa Purua Geothermal

More information

A Sub-Synchronous Vibration Problem: Trapped Fluid in Compressor Coupling Spacer. Diagnosis and Resolution

A Sub-Synchronous Vibration Problem: Trapped Fluid in Compressor Coupling Spacer. Diagnosis and Resolution A Sub-Synchronous Vibration Problem: Trapped Fluid in Compressor Coupling Spacer Diagnosis and Resolution September 10-13, 2007 John E Sutton Chevron Energy Technology Company Pty Ltd Perth, Western Australia

More information

Minimum standard of competence in advanced training for liquefied gas tanker cargo operations (STCW Reg V/1-2)

Minimum standard of competence in advanced training for liquefied gas tanker cargo operations (STCW Reg V/1-2) Minimum standard of in advanced training for liquefied gas tanker cargo operations (STCW Reg V/1-2) Column 2 Knowledge, understanding and proficiency Design and characteristics of a liquefied gas tanker

More information

WHITEPAPER. Integrated process monitoring of dosing pressures

WHITEPAPER. Integrated process monitoring of dosing pressures Integrated process monitoring of dosing pressures Detect and avoid errors during dosing with the flowplus 16 dosing pressure monitoring system and flowscreen Fig. 1: flowplus 16 relative pressure sensor

More information

Official Journal of the European Union L 92/3

Official Journal of the European Union L 92/3 3.4.2008 Official Journal of the European Union L 92/3 COMMISSION REGULATION (EC) No 303/2008 of 2 April 2008 establishing, pursuant to Regulation (EC) No 842/2006 of the European Parliament and of the

More information

E 084 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 80 l/min / 21.1 gpm

E 084 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 80 l/min / 21.1 gpm Return-Suction Filters E 08 Tank top mounting Connection up to G / -6 SE Nominal flow rate up to 80 l/min /. gpm Description pplication For operation in units with hydrostatic drives, when the return flow

More information

product manual HM-4140, HM-4150, HM-4160 HM-4160A HM-4150 Humboldt FlexPanels

product manual HM-4140, HM-4150, HM-4160 HM-4160A HM-4150 Humboldt FlexPanels 12.09 product manual HM-4140, HM-4150, HM-4160 HM-4160A HM-4150 Humboldt FlexPanels Introduction: This manual covers the installation and operation of Humboldt FlexPanels for Triaxial and Permeability

More information

Chemical Feed Equipment Floor-Mounted Gas Dispenser - Series CH4200

Chemical Feed Equipment Floor-Mounted Gas Dispenser - Series CH4200 Specification Bulletin (rev.01) Series CH4200 Chemical Feed Equipment Floor-Mounted Gas Dispenser - Series CH4200 Easy, fast& accurate digital with 11 points calibration Laser sensor offering actual feed

More information

Siphon vessel / Priming aid

Siphon vessel / Priming aid Manufacturer: sera GmbH sera-straße 1 34376 Immenhausen Germany Tel.: +49 5673 999-00 Fax: +49 5673 999-01 info@sera-web.com Keep the operating manual for future use! Record the exact type and serial number

More information

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DATA SHEET N 186 N 186.1.2 ST.12 E Concept The diaphragm pumps from KNF are based on a simple principle an elastic diaphragm, ixed on its edge, moves up and down

More information

29th Monitoring Research Review: Ground-Based Nuclear Explosion Monitoring Technologies

29th Monitoring Research Review: Ground-Based Nuclear Explosion Monitoring Technologies IMPROVED CALIBRATION AND OPERATION OF A STABLE-GAS QUANTIFICATION MANIFOLD AS PART OF A RADIOXENON COLLECTION SYSTEM ABSTRACT Richard M. Williams, James C. Hayes, and Randy R. Kirkham Pacific Northwest

More information

Over the last decade, mechanical vacuum systems

Over the last decade, mechanical vacuum systems Explosion protection safety concept for use in mechanical vacuum pump systems in secondary metallurgy steel degassing processes Today s international standards for mechanical vacuum systems are based on

More information

Traysealer T 100. Tray packaging in the smallest space

Traysealer T 100. Tray packaging in the smallest space Traysealer T 100 Tray packaging in the smallest space MULTIVAC T 100 Traysealer T 100 Tray packaging in the smallest space The compact, semiautomatic Traysealer T 100 easily and economically packs products

More information

MULTI-STAGE VACUUM GENERATORS PVP M

MULTI-STAGE VACUUM GENERATORS PVP M MULTI-STAGE VACUUM GENERATORS PVP 40 300 M This new range of multi-stage vacuum generators have been designed to be assembled onto OCTOPUS vacuum systems and represents a true evolution of traditional

More information

deltaflowc deltaflowc Venturi or Probe

deltaflowc deltaflowc Venturi or Probe deltaflowc Mass Flowmeter for Gases - Multivariable with ultra fast dp, p and T-sensors - Compact, accurate and user-friendly - Ideal for OEMs deltaflowc Venturi or Probe Precise mass flow metering deltaflowc

More information

Active Hydrophore System AHS-01

Active Hydrophore System AHS-01 BRIEF PRODUCT DESCRIPTION: Standard material Seawater exposed parts: Titanium gr. 2 Rapid Response Valves: Titanium gr. 2 Cabinet: SST AISI 316 This is a skid mounted unit, with the hydrophore tank and

More information

IMPORTANT PLEASE READ BEFORE COMMENCING INSTALLATION

IMPORTANT PLEASE READ BEFORE COMMENCING INSTALLATION IMPORTANT PLEASE READ BEFORE COMMENCING INSTALLATION This Fitting Guide is designed to assist in the Installation of your Reverse Osmosis System. Some of the parts that are supplied with each system may

More information

Moving Fluids Concept and Theory

Moving Fluids Concept and Theory Moving Fluids Concept and Theory Graco, Inc. P.O. Box 1441 Minneapolis, MN 55440-1441 1995 Graco Inc. Form No. 321-037 12/95 Rev 2 SL Training 11/14 Understanding Your Customer s Situation Characteristics

More information

Construction Dewatering

Construction Dewatering Construction Dewatering Introduction The control of groundwater is one of the most common and complicated problems encountered on a construction site. Construction dewatering can become a costly issue

More information

Lecture 19 PRESSURE-CONTROL VALVES [CONTINUED]

Lecture 19 PRESSURE-CONTROL VALVES [CONTINUED] Lecture 19 PRESSURE-CONTROL VLVES [CONTINUED] 1.5 Counterbalance Valve Schematic diagram of counterbalance valve is shown in Fig. 1.14. These normally closed valves are primarily used to maintain a back

More information

Tubes Components Valves Units Engineering SO EVERYTHING KEEPS FLOWING. Safety valves Bunging valves Vacuum valves Tank dome fittings

Tubes Components Valves Units Engineering SO EVERYTHING KEEPS FLOWING. Safety valves Bunging valves Vacuum valves Tank dome fittings SO EVERYTHING KEEPS FLOWING Safety valves Bunging valves Vacuum valves Tank dome fittings Reliable reaction at the right moment Safety components are part of our everyday life. Like anti-skid systems in

More information

EDUCTOR. principle of operation

EDUCTOR. principle of operation EDUCTOR principle of operation condensate and mixing eductor s are designed to mix two liquids intimately in various proportions in operations where the pressure liquid is the greater proportion of the

More information