Operation Manual. Voyager III TM. Nitrox System Rev 03.15

Size: px
Start display at page:

Download "Operation Manual. Voyager III TM. Nitrox System Rev 03.15"

Transcription

1 Operation Manual Voyager III TM Nitrox System Rev 03.15

2 If you have any questions on this equipment please contact Technical Support at: Nuvair 1600 Beacon Place Oxnard, CA Phone: FAX: Hours: Monday through Friday 8:00 AM to 5:00 PM PST USA This Operation Manual contains important safety information and should always be available to those personnel operating this equipment. Read, understand, and retain all instructions before operating this equipment to prevent injury or equipment damage. Every effort was made to ensure the accuracy of the information contained within. Nuvair, however, retains the right to modify its contents without notice. If you have problems or questions after reading the manual, stop and call Nuvair at for information. Page 2

3 Introduction Table of Contents 1.0 Introduction 2.0 Safety Warnings 3.0 Safety and Operation Precautions 4.0 Legal Precautions 5.0 Theory of Operation 6.0 Low Pressure Air Compressor Technical Data 7.0 High Pressure Compressor Technical Data 8.0 System Components 9.0 Nitrox System Specifications 10.0 Nitrox System Component Identification 11.0 System Drawing/Schematic 12.0 System Flow Chart Setup, Operation, and Maintenance 13.0 Installing the Nitrox System 13.1 Precautions 13.2 Attaching Nitrogen Discharge Hose (Optional) 13.3 Electrical Power Connection 13.4 Check Compressor Lubricant Levels 13.5 Control Pane Description 14.0 Pre-Operation Instructions 14.1 Oxygen Analyzer Calibration 15.0 Producing Nitrox 15.1 Flow to Membrane and Setting Proper Pressure 15.2 Final Adjustments Before Pumping Nitrox 15.3 Pumping Nitrox 15.4 Pumping Air 15.5 Shutting Down 16.0 Nitrox Operational Notes 16.1 Correlation of Feed Air Pressure to Oxygen Content 16.2 Hot Fills 17.0 Maintenance 17.1 Daily Maintenance 17.2 Routine Maintenance 17.3 Compressor Lubricant 17.4 LP Feed Air Filtration 17.5 HP Compressor Filtration 17.6 Spare Parts List 17.7 Service Record Log Appendix Supply and Breathing Air Specifications Filter Element Life Factors Material Safety Data Sheets Owner s Warranty Responsibilities Warranty Separate Manuals Included: Nuvair Pro O 2 TM Oxygen Analyzer Operation Manual Rotair RVK 8-20 Compressor Manual High Pressure Compressor Manual Page 3

4 1.0 Introduction Nuvair has taken extreme care in providing you with the information you will need to operate this system. However, it is up to you to carefully read this manual and make the appropriate decisions about system safety. This manual will assist you in the proper set-up, operation and maintenance of the Nuvair Voyager III TM Nitrox System. Be sure to read the entire manual. Throughout this manual we will use certain words to call your attention to conditions, practices or techniques that may directly affect your safety. Pay particular attention to information introduced by the following signal words: Indicates an imminently hazardous situation, which if not avoided, will result in serious personal injury or death. Indicates a potentially hazardous situation, which if not avoided, could result in serious personal injury or death. Indicates a potentially hazardous situation, which if not avoided, may result in minor or moderate injury. It may also be used to alert against unsafe practices. Notifies people of installation, operation or maintenance information which is important but not hazard-related. Page 4

5 2.0 Safety Warnings This equipment is used to provide breathing gas for the purpose of underwater life support. Read this manual in its entirety. Failure to heed the warnings and cautions contained in this document may result in severe injury or death. The equipment you will be using to manufacture Nitrox (oxygen rich air) will expose you to both low and high-pressure gas. Gas, even under moderate pressures, can cause extreme bodily harm. Never allow any gas stream to be directed at any part of your body. Any pressurized hose can cause extreme harm if it comes loose or separates from its restraint (or termination) while under pressure and strikes any part of your body. Use appropriate care in making and handling all gas connections. Pure nitrogen is a colorless, odorless, tasteless gas that will not support life. Breathing gas mixtures containing more than 84% nitrogen at surface pressures will lead to unconsciousness and may cause death. The nitrogen discharge from the Membrane System must be vented to the exterior of any closed building, boat, or similar enclosed space. Breathing gas mixtures containing more than 84% nitrogen at surface pressure will lead to unconsciousness and may cause death. Do not use any form of mineral oil or synthetic lubricant not rated for Nitrox in any Compressor in this system. Use only the recommended Nitrox Compressor Lubricant. Never mix the Nitrox Compressor Lubricant with other lubricants. Remove all existing lubricant and replace with the proper Nitrox Compressor Lubricant prior to installing the Membrane System. The use of improper lubricants can lead to fire or explosions, which may cause serious personal injury or death. Do not use this system to produce Nitrox mixtures containing more than 40% oxygen. Pumping Nitrox mixtures with higher concentrations of oxygen may lead to fires or explosions, which can cause serious personal injury or death. Page 5

6 The use of enriched air Nitrox does not eliminate the risk of decompression sickness (DCS) in diving. Decompression sickness can lead to permanent disability or death. Do not pump Nitrox mixtures at pressures above the HP Compressor manufacturer s rating, and never above 3600 P.S.I. (250 bar). The system is not rated for pressures above 3600 P.S.I. (250 bar). Higher pressures may lead to explosions which may cause serious personal injury or death. Ambient room temperature should never exceed 100 o F (38 o C) during operation of the Nitrox System. Operation at higher temperatures may lead to system damage and malfunction. A damaged membrane will not produce the correct Nitrox mixture which can lead to severe personal injury if the gas is used for diving purposes without proper analysis. Page 6

7 3.0 Safety And Operation Precautions Because a compressor is a piece of machinery with moving and rotating parts, the same precautions should be observed as with any piece of machinery of this type where carelessness in operations or maintenance is hazardous to personnel. In addition to the many obvious safety precautions, those listed below must also be observed: 1) Read all instructions completely before operating any compressor or Nitrox System. 2) For installation, follow all local electrical and safety codes, as well as the National Electrical Code (NEC) and the Occupational Safety and Health Administration (OSHA) standards. 3) Electric motors must be securely and adequately grounded. This can be accomplished by wiring with a grounded, metal-clad raceway system to the compressor starter; by using a separate ground wire connected to the bare metal of the motor frame; or other suitable means. 4) Protect all power cables from coming in contact with sharp objects. Do not kink power cables and never allow the cables to come in contact with oil, grease, hot surfaces, or chemicals. 5) Make certain that power source conforms to the requirements of your equipment. 6) Pull main electrical disconnect switch and disconnect any separate control lines, if used, before attempting to work or perform maintenance. Tag Out or Lock Out all power sources. 7) Do not attempt to remove any parts without first relieving the entire system of pressure. 8) Do not attempt to service any part while System is in an operational mode. 9) Do not operate the System at pressures in excess of its rating. 10) Do not operate compressor at speeds in excess of its rating. 11) Periodically check all safety devices for proper operation. Do not change pressure setting or restrict operation in any way. 12) Be sure no tools, rags or loose parts are left on the Nitrox System. 13) Do not use flammable solvents for cleaning the Air Inlet Filters or elements and other parts. 14) Exercise cleanliness during maintenance and when making repairs. Keep dirt away from parts by covering parts and exposed openings with clean cloth or Kraft paper. 15) Do not operate the compressor without guards, shields, and screens in place. 16) Do not install a shut-off valve in the compressor discharge line, unless a pressure relief valve, of proper design and size, is installed in the line between the compressor unit and shut-off valve. 17) Do not operate in areas where there is a possibility of inhaling carbon monoxide, carbon dioxide, nitrogen, or flammable or toxic fumes. 18) Be careful when touching the exterior of a recently run electric, gasoline, or diesel motor - it may be hot enough to be painful or cause injury. With modern motors this condition is normal if operated at rated load - modern motors are built to operate at higher temperatures. 19) Inspect unit daily to observe and correct any unsafe operating conditions found. 20) Do not play around with compressed air, nor direct air stream at body, because this can cause injuries. 21) Compressed air from this machine absolutely must not be used for food processing or breathing air without adequate downstream filters, purifiers and controls and periodic air quality testing. 22) Always use an air pressure-regulating device at the point of use, and do not use air pressure greater than marked maximum pressure. 23) Check hoses for weak or worn conditions before each use and make certain that all connections are secure. The user of any compressor or Nitrox System manufactured by Nuvair is hereby warned that failure to follow the preceding Safety and Operation Precautions can result in injuries or equipment damage. However, Nuvair does not state as fact or does not mean to imply that the preceding list of Safety and Operation Precautions is all-inclusive, and further that the observance of this list will prevent all injuries or equipment damage. Page 7

8 4.0 Legal Precautions It is highly recommended that a Nitrox fill log be maintained when filling Scuba cylinders to document the following information. This log must be of permanent binding style with no loose pages. Fill date and time of day Tank Number Supplier s check of oxygen content (%O 2 ) plus signature and date User s check of oxygen content (%O 2 ) plus signature and date Fill Pressure MOD (Maximum Operating Depth) in user s handwriting Nitrox certifying agency and card number Page 8

9 5.0 Theory of Operation Voyager III TM Nitrox System The Voyager III TM Nitrox System is a turnkey package that produces oxygen-rich air (Nitrox) and then compresses it with a High Pressure (HP) Compressor to fill Scuba Tanks or storage cylinders. The package is designed to be fully automatic, with a quieted enclosure for noise reduction and protection from moving parts while it is running. Although it is described as the Nitrox Compressor, it can also be used to pump air. The Nitrox System allows for efficient and cost effective Nitrox production using electric power, without the hazards or expense of blending with stored high-pressure oxygen (O 2 ). Instead, the system uses a Semi-Permeable Membrane to produce Nitrox from air. A portion of the nitrogen in air is separated out, leaving an oxygen rich Nitrox mixture. The Voyager III TM uses a Rotary Screw LP Compressor, Air/Oil Aftercooler, Refrigerated Air Dryer, and Filtration to provide the Membrane System with a source of clean, pressurized feed air for separation. The air is filtered to CGA Grade D or better air quality prior to entering the Membrane System so it will not damage or plug the Membrane fibers. Specifications for Grade D air are provided in the Appendix. The Voyager III TM s Membrane System is rated for a maximum feed air pressure of 300 P.S.I. (21 bar) and has been configured to work well with the 175 P.S.I (12 bar) maximum pressure delivered by the LP Compressor. A Back Pressure Regulator is used to adjust the amount of air the screw compressor produces to meet the appropriate levels for various %O 2 Nitrox production. The air is then heated to a temperature that provides stability over a wide range of ambient conditions, is optimal for Membrane permeation, and prevents moisture condensation. The heated air enters the Membrane, which is made up of thousands of miniature hollow fibers. The walls of these fibers are semi-permeable and designed for different gases to move through them (or permeate) at different speeds. The resulting gas mixture is known as the permeate. As air flows through the hollow fibers, both oxygen and nitrogen permeate through the fiber walls. The oxygen permeates faster than the nitrogen, which produces permeate with oxygen content greater than air. The gas that reaches the end of the hollow fibers without permeating is almost entirely nitrogen and is discharged. The flow rate of this discharge is set by the factory via a fixed orifice, which controls the permeate to contain a constant 44% O 2 under normal operating conditions. The permeate is a concentrated mixture that must be diluted with additional air prior to entering the HP Compressor. It exits the Membrane at ambient to slightly negative pressure and travels into the Mixing Tube, where it mixes homogeneously with filtered outside air. The amount of dilution, and thus final %O 2, is obtained by adjusting the amount of air produced by the compressor and supplied to the membrane, with the Back Pressure Regulator. As air flow to the membrane is increased, permeate flow increases and a higher %O 2 Nitrox is produced. As air intake flow to the membrane is decreased, permeate flow decreases, compressor intake air increases, and a lower %O 2 Nitrox is produced. This relationship between permeate flow and intake air flow exists because the total of these two flow rates will always equal the intake flow rate demanded by the HP Compressor. The resulting Nitrox mixture is analyzed for %O 2 before entering the HP Compressor for approximate content and again when pumping Nitrox for precise content. The HP Compressor pumps the Nitrox to a maximum pressure of 3600 psi (250 bar) to fill Scuba Tanks or storage cylinders. A unique feature of Nuvair Nitrox Systems is that the feed air pressure that correlates to a specific Nitrox %O 2 is repeatable. For example, if your HP Compressor pumps 36% O 2 when the feed air pressure is at 125 P.S.I. (9 bar), then adjusting the Back Pressure Regulator to 125 P.S.I. (9 bar) during the next use will produce the same mixture. Page 9

10 6.0 Low Pressure Compressor Technical Data See Separate Manual for Rotair RVK 8-20 Capacity and Power Consumption: Normal working pressure P.S.I. ( bar) Capacity at normal working pressure 43 cfm (1218 l/min) Shaft power at normal working pressure 15 hp (11 kw) Maximum working pressure 175 P.S.I. (12 bar) Minimum working pressure 44 P.S.I. (3 bar) Idling shaft power consumption 2.3 hp (1.7 kw) Transmission Belt drive Cooling: Allowed ambient temperature F (0-40 C) Compressed air temperature above cooling medium temperature 50 F (10 C) Cooling air flow 635 cfm (0.3 m³/s) Maximum cooling air pressure drop 0.12 in H 2 O (30 Pa) Cooling air temperature rise 64 F (18 C) Oil cooler heat rejection 324 BTU/min (5.7 kw) Aftercooler heat rejection 40 BTU/min (0.7 kw) 3 phase Motor Class F ODP and Electrical Values: Motor - F class, 15hp (11 kw) Speed of rotation 3450 rpm Fuse (max) v v Compressor current 24 A at 380 V / 50 Hz or / 440 volt /60Hz Control voltage 230 V General Technical Data: Oil Capacity 4 liters Maximum Oil Content in Air 3 mg/m 3 Page 10

11 7.0 High Pressure Compressor Technical Data See Separate Manual for Coltri HP Compressor Specs reflect MCH Model Capacity and Power Consumption: Normal working pressure 3600 P.S.I. (250 bar) F.A.D. Flow 11cfm (311 l/m) Charging Rate 13 SCFM (368 l/min) Compressor speed of rotation 950 rpm Maximum working pressure Air 5000 P.S.I. (354 bar), Nitrox 3600 P.S.I. (248 bar) Transmission Belt drive Cooling: Allowed ambient temperature F (0-40 C) Air Cooled Interstage & Aftercooler Motor and Electrical Values: Motor - 10hp 3 phase Speed of rotation 3450 rpm Compressor current 230V Hz/three phase 28A 440V Hz/three phase 14A General Technical Data: Number Of Stages 4 Number Of Cylinders 4 Lubrication Pressure & Splash Lubricated Oil Quantity 4.25 qt. (5 liters) HP Filtration Rating CGA Grade E, 65,000 cu. ft. at 68 o F (20 o C) Condensate Drains Automatic & Manual Interstage & Final Fill Pressure Stop Automatic & Manual Low Oil Level Shutdown High Temperature Shutdown Interstage Pressure Gauges Page 11

12 8.0 System Components Low Pressure Compressor, including: Magnet Motor Starter Hour Meter External Lubricant Sight Gauge, Fill, and Drain Nuvair 546 TM Food Grade Rotary Screw Compressor Lubricant Large oil/air cooler with exhaust fan Refrigerated Air Dryer Automatic Condensate Drain Back Pressure Regulator that controls LP compressor feed air supply Supply Air Pressure Gauge P.S.I. (6-11 bar) depending on Nitrox %O 2 Low Pressure Feed Air Filtration, Grade D Breathing Air, including four stages: Coalescing & Particle Removal to 1 micron, auto drain, liquid level indicator Water & Oil Vapor Removal to 0.01 micron, auto drain, liquid level & service life indicators Oil Vapor Removal to PPM Heater including: (optional) not supplied with Nitrox Manager Thermostat Control Digital Temperature Gauge Pressure Switch 200 P.S.I. (14 bar) ASME Over Pressure Relief Semi-Permeable Membrane Mixing Tube & Air Intake Filter Nuvair Pro O 2 Remote TM Permeate Oxygen Analyzer Nitrogen Discharge Nuvair Pro O 2 TM Fill Oxygen Analyzer, including: High Pressure>Low Pressure Regulator Flow Restrictor, 1-5 L/min High Pressure Compressor, including Magnet Motor Starter Hour Meter Automatic Condensate Drains Automatic Fill Pressure Stop External Lubricant Sight Gauge, Fill, and Drain Nuvair 455 TM Food Grade Compressor Lubricant High Pressure Filtration, Grade E Breathing Air Air/Nitrox Quality Analysis Kit Page 12

13 9.0 Nitrox System Specifications LP Compressor Physical Specifications Full Load Amps 175 P.S.I. (12 bar) Horsepower Electric Height Width Depth Weight 230V/E3/50-60 Hz 440V/E3/50-60 Hz 43 cfm FA (1218 L/min) 15 hp (11 kw) 62 in (157 cm) 57 in (145 cm) 32 in (81 cm) 1400 lb (635 kg) 68A 34A Operating Pressure Range psi (6-12 bar) Membrane Input Maximum Input Pressure 300 psi (21 bar) Feed Air Volume Range 8-43 scfm ( L/min) LP Feed Air Quality Grade D Optimum Temperature 110 +/- 5 o F (43 +/- 3 o C) Nitrox %O 2 Range 24-40% HP Compresso r Charging Rate Horsepower Electric 13 SCFM (368l/min) 10 hp (7.46 kw) Page 13

14 10.0 Nitrox Voyager II System Component Identification Stage Pressure Gauges Fill Oxygen Analyzer Low Pressure Compressor Momentary On Switch & Hour Meter LP Back Pressure Regulator Adjustment Knob - Adjust Nitrox O 2 % Here Low Pressure Gauge Cabinet Temperature HP Oil Pressure Gauge Fill Pressure Gauge High Pressure Compressor On/Off Switch & Hour Meter Permeate Oxygen Analyzer Heater Thermostat Control LP Oil Temperature HP Compressor Filter Canisters Filter # X65247 Filter # X65677 HP Fill Outlet Condensate Container with Muffler & Drain HP Filter Pressure Bleed Page 14

15 Final HP Condensate Tower HP & LP Oil Fill LP Air Intake LP Oil Filter LP Oil/Air Separator HP Compressor Lubricant Level Sight Gauge HP & LP Oil Drains Membrane HP Air Intake Heater HP Motor Control Electric Box Refrigerated Air Dryer LP Feed Air Filtration (4 Stage) LP Motor Control Electric Box Page 15

16 11.0 System Drawing / Schematic Voyager III TM Nitrox System Components Shown Within Dashed Lines Page 16

17 12.0 System Flow Chart LP Compressor Produces LP Feed Air ( Supply Air ) LP Aftercooler Removes Moisture BP Regulator Controls the amount of Feed Air pumped by the compressor Voyager III TM Nitrox System Components Shown Within Dashed Lines Refrigerated Air Drier cools the air Moisture Separator in Drier removes moisture Thermostat Controlled Heater Heats Air to 110ºF (43ºC) LP Feed Air Filtration Produces Grade D Air Membrane Separates Supply Air Into Permeate and Nitrogen Rich Gas Nitrogen Rich Gas Exits Through Fixed Orifice located by exhaust cooling air vent Permeate Exits Membrane Containing 44% O2 Air Intake Delivers Filtered Ambient Air to Mixing Tube Optional Vacuum Pump or Blower Mixing Tube Mixes Air & Permeate to Create Nitrox Containing 24-40% O2 Permeate O2 Analyzer Monitors Nitrox before Compression to +/- 2% O2 HP Compressor with Moisture Removal & Filtration Compresses Nitrox Fill O2 Analyzer Monitors Nitrox Mixture to +/- 1% O2 HP Nitrox Delivered to Scuba Cylinder - OR - HP Nitrox Delivered to Storage Page 17

18 13.0 Installing the Voyager III Nitrox System If any information in this manual conflicts with any of the other manuals call Nuvair before proceeding. Ambient room temperature should never exceed 100 o F (38 o C) during operation of the Nitrox System. Operation at higher temperatures may lead to system damage and malfunction. A damaged membrane will not produce the correct Nitrox mixture which can lead to severe personal injury if the gas is used for diving purposes without proper analysis Precautions 1. Please read all information supplied before physically installing the Nitrox System. 2. Unpack the system and remove from the pallet. Visually inspect the system to make sure there has been no damage during shipping. If damaged, please call Nuvair to file a damage report. Please take photos and supply detailed information about the damage. 3. Place the system in a location that allows a minimum spacing of 18 from adjacent walls. Select a location where ambient room temperature will never exceed 100 o F (38 o C). 4. The Heater Thermostat has been set in the factory. Do not adjust Nitrogen Discharge Hose The nitrogen discharge from the Membrane on the Voyager III exits next to the exhaust air fan. The fan pushes over 3000 cfm of exhaust air and as long as the fan is functioning there will be no need for an outside optional discharge, unless installed in a properly ventilated room. Pure nitrogen is a colorless, odorless, tasteless gas that will not support life. Breathing gas mixtures containing more than 84% nitrogen at surface pressures will lead to unconsciousness and may cause death. The nitrogen discharge from the Membrane should be vented to a well-ventilated room or to open air with good circulation. Failure to isolate the discharge from the air intake of the Membrane System or LP Compressor could lead to incorrect Nitrox mixtures, resulting in serious personal injury or death. If you allow this pure nitrogen to accumulate in an enclosed space, anyone entering this space will quickly lose consciousness and will die if not immediately resuscitated. Page 18

19 13.3 Electrical Power Connection Never use extension cords to provide power to your Nitrox System. The system must be properly wired according to national and local electrical codes by a qualified electrician. Improper wiring may lead to fires, which can cause serious personal injury or death. Prior to making the electrical power connection, check all system specifications provided in this manual. When working on the Nitrox System the main breaker at the power source must be locked out in the Off position. The Nitrox System has electrical protection for the Compressor Motor and Membrane System Heater located inside the motor starter compartment. Amperage Load for System Approximately 68 A for 230 V three phase service Approximately 34 A for 440 V three phase service HP Hour Meter LP Hour Meter Compressor Rotation Check HP On/Off Switch LP On/Off Switch Always turn on (bump) starter for both LP and HP Compressors and run motor very briefly to check for proper direction of rotation (see arrow on belt guard and flywheel). HP Compressor Shown Note Proper Direction of Rotation Operation in reverse direction for extended periods of time will cause a Reciprocating Compressor to run hot and perform poorly and may cause permanent damage. Reverse rotation for a rotary screw compressor for even a short period of time will cause damage. Page 19

20 13.4 Check Compressor Lubricant Levels Check lubricant levels before starting the LP and HP Compressors, and add lubricant as required. Use only the lubricants specified. LP Oil Fill & Dip Stick Compressor Lubricant Level Sight Gauges Do not allow Nitrox to be discharged into the air storage system. Nitrox introduced into the air storage system could cause a diver to suffer from oxygen poisoning at depth. Oxygen poisoning is extremely dangerous and can lead to drowning. Do not allow air to be discharged into the Nitrox storage system. Air introduced into the Nitrox storage system could cause a diver to suffer decompression sickness if the Nitrox mixture is not analyzed properly and is used underwater under the assumption it is a different mix Control Panel Controls HP Compressor Oil Pressure Gauge O2 Analyzers LP Feed Air Regulator Adjustment Knob Feed Air Pressure Gauge Cabinet Temperature Gauge Stage Pressure Gauges Fill Pressure Gauge On/Off Switches Heater Temperature Gauge LP Compressor Oil Temperature Page 20

21 14 Pre-Operation of Compressor Before Producing Nitrox 14.1 Calibrate Oxygen Analyzers Gas production is monitored with the Permeate Oxygen Analyzer before entering the HP Compressor to obtain a rough estimate of %O 2 (+/- 2%); however, do not rely on this reading as an indication of %O 2 at the HP Compressor outlet. Prior to pumping Nitrox from the Compressor, it must be monitored with the Fill Oxygen Analyzer to obtain a precise measurement of %O 2 (+/- 1%). Both Oxygen Analyzers must be calibrated prior to each use. Oxygen Analyzers must be calibrated before each use. See Oxygen Analyzer manuals for correct calibration procedures. Improper calibration of the Fill Oxygen Analyzer may result in the use of incorrect Nitrox mixtures, which may cause serious injury or death to the diver using the gas mixture. At altitudes above sea level, a correction factor must be used when calibrating the Fill Oxygen Analyzer may not be achievable. See Fill Oxygen Analyzer manual for correcting analyzer readings at various altitudes. Improper calibration of the Fill Oxygen Analyzer may result in the use of incorrect Nitrox mixtures, which may cause serious injury or death to the diver using the gas mixture. The Permeate Oxygen Analyzer supplies oxygen readings that can vary +/- 2% O 2 due to heat, humidity, and pressure changes experienced in the Nitrox flow and therefore should only be used for rough estimates of %O 2. The Fill Oxygen Analyzer supplies more accurate oxygen readings, within +/- 1% O 2. For Scuba cylinder Nitrox fills, the user must always verify the final fill with a third independent Oxygen Analyzer. Page 21

22 Compressor Controls Voyager III TM Nitrox System On/Off Knob for HP Compressor Fill Oxygen Analyzer Provides Precise Reading Calibration Knob Permeate Oxygen Analyzer Provides Rough Reading 1) Turn on the High Pressure Compressor and allow to run for 1-2 minutes or until Analyzers stabilize. 2) Crack open the bleed valve on the side of the compressor so that the running HP Compressor maintains P.S.I. ( bar) outlet pressure. Air will now be flowing past both Oxygen Analyzers for calibration purposes. 3) Monitor all gauges for proper operating range and check all connections for leaks.(page 20) 4) Calibrate Oxygen Analyzers while the HP Compressor is pumping air. Refer to the Oxygen Analyzer manual included with the Nitrox System for details. Note that special calibration procedures may be required when operating at altitudes above sea level. Permeate Oxygen Analyzer Turn calibration knob so display reads 20.9%. a. Fill Oxygen Analyzer Remove the Flow Adapter Cap covering the Sensor. b. Expose the Sensor to ambient air for approximately 15 seconds. c. Adjust Calibration Knob until Display reading stabilizes at 20.9%. d. Reinstall the Flow Adapter Cap to the analyzer. e. The Fill Oxygen Analyzer is now ready for use. Different settings may be used depending on location, so verify your actual ambient conditions and refer to the Oxygen Analyzer manual for details. 5) Turn on the LP Compressor and increase the pressure to a minimum of 90 P.S.I. 6) Allow the Compressors to run for a 10 Minute warm up period for the Membranes to warm up and stabilize. Check the Heater Fill Oxygen Analyzer Sensor Cap Removed Calibration Knob Temperature Gauge to verify air temperature rises and is between ºF (40-49 ºC). 7) Turn off LP Compressor and Re-Calibrate The Fill Analyzer. 8) Now that the System Temperature has stabilized You must Re-Calibrate the Fill O 2 Sensors. See Step 4a above. The Oxygen Analyzers may require re-calibration after minutes of operation due to humidity and temperature change effects on the Sensor. To recalibrate, Turn off the LP Feed Air and follow calibration instructions. Page 22

23 15.0 Producing Nitrox Before using your Nitrox System to pump Nitrox, test a sample of the Nitrox produced using the Air/Nitrox Quality Analysis Kit provided to verify compliance with CGA standards. Quarterly testing is mandatory once the System is operational. The equipment you will be using to manufacture Nitrox (oxygen rich air) will expose you to both low and high-pressure gas. Gas, even under moderate pressures, can cause extreme bodily harm. Never allow any gas stream to be directed at any part of your body. Do not change the temperature setting on the Thermostat Control without contacting Nuvair. Changes in temperature settings may cause Membrane damage. A damaged membrane will not produce the correct Nitrox mixture which can lead to severe personal injury if the gas is used for diving purposes without proper analysis Flow to Membrane and Setting Proper Pressure The Membrane System feed air pressure determines the %O 2 of the Nitrox mixture. As pressure is increased, a higher %O 2 Nitrox is pumped. As pressure is decreased, a lower %O 2 is pumped. 1) Increase pressure by slowly turning the regulator Knob CW while monitoring the LP Pressure Gauge and Permeate Oxygen Analyzer. As the pressure rises, watch the corresponding increase in the analyzer %O 2 reading. 2) Increase or decrease pressure slowly until the Permeate Oxygen Analyzer displays the %O 2 desired in the final Nitrox mixture. Regulated Membrane System pressure range should be P.S.I ( bar), depending on Nitrox %O 2 being produced. Heater temperature range should be ºF (40-49 ºC) Final Adjustments Before Pumping Nitrox Permeate Oxygen Analyzer 1) As the Nitrox initially makes its way through the running HP Compressor, the %O 2 reading on the Fill Oxygen Analyzer will slowly increase to read approximately the same %O 2 as the Permeate Oxygen Analyzer. This should happen within 3-5 minutes. 2) When the two analyzers read within +/- 1%, make any final adjustments to the Membrane System feed air pressure necessary to obtain the exact Nitrox %O 2 desired as indicated on the Fill Oxygen Analyzer. 3) The system is now ready to pump Nitrox. 4) Now you re ready to close Bleed Valve and open Storage System. Fill Oxygen Analyzer Page 23

24 The use of enriched air Nitrox does not eliminate the risk of decompression sickness (DCS) in diving. Decompression sickness can lead to permanent disability or death.\ The Permeate O 2 Analyzer supplies oxygen readings that can vary +/- 2% O 2 due to heat, humidity, and pressure changes in the Nitrox flow and should only be used for rough estimates of %O 2. The Fill O 2 Analyzer supplies more accurate readings, within +/- 1% O 2. For Scuba cylinder fills, the user must always verify the fill with a third independent O 2 analyzer. Do not use this system to produce Nitrox mixtures containing more than 40% oxygen. Pumping Nitrox mixtures with higher concentrations of oxygen may lead to fires or explosions, which can cause serious personal injury or death. Do not pump Nitrox mixtures at pressures above the HP Compressor rating, and never above 3600 P.S.I. (250 bar). The system is not rated for pressures above 3600 P.S.I. (250 bar). Higher pressures may lead to explosions which may cause serious personal injury or death. No oxygen cleaning of standard cylinders or plumbing is mandatory when using the Nitrox System to produce Nitrox containing a maximum of 40% oxygen. When filling oxygen clean cylinders, hyper-purification of the Nitrox is required using an optional Oxygen Compatible Air purification system available from Nuvair. This Nitrox System does not produce Nitrox mixtures acceptable for 100% oxygen service. Never fill a cylinder that is marked, For Oxygen Service, with Nitrox that has been produced by anything other than 100% oxygen clean system. Filling an oxygen clean cylinder with breathing gas containing hydrocarbons can lead to explosions if the cylinder is subsequently filled with gas mixtures containing gas mixtures containing greater than 40% oxygen. Only provide Scuba cylinder Nitrox fills to customers who have proof of Nitrox training and certification. Improper use of Nitrox can be fatal. Page 24

25 This system is not cleaned for oxygen service and not all components are compatible with gas mixtures containing greater than 40% oxygen. Pumping gas mixtures containing greater than 40% oxygen will lead to explosions which may cause severe personal injury or death. Each Scuba cylinder belonging to a customer must be analyzed by that customer at the Nitrox filling facility, using an oxygen analyzer independent of those used with the Nitrox System. An employee must witness that the customer has properly analyzed the gas in each cylinder, noted the maximum operating depth for that mixture, and signed and dated the fill log. The time of day must also be included with the date, since some customers may fill the same cylinder more than once a day Pumping Nitrox 1) When filling a Scuba cylinder, follow all industry standards. Do not exceed rated pressure of cylinder, and do not exceed 3600 P.S.I. (250 bar) under any condition. 2) With fill whip bleed valve open and Nitrox flowing, verify that Fill Oxygen Analyzer %O 2 reading equals the desired Nitrox %O 2. 3) Close bleed valve, open cylinder valve, and fill cylinder. Monitor system for proper operation: a) Monitor Oxygen Analyzers and recalibrate as required b) Listen for proper operation of automatic condensate drains every minutes. c) Monitor all system gauges as shown in the table below. The Oxygen Analyzers may require re-calibration after minutes of operation due to humidity and temperature change effects on the Sensor. To recalibrate, turn off the LP Feed Air Switch and follow calibration instructions. When the HP Compressor auto drain engages and dumps condensate, the Fill Oxygen Analyzer reading will decrease momentarily due to the pressure drop in the system. It will return to its previous reading within seconds after the auto drain sequence stops. GAUGE Compressor Gauges Heater Temperature o F (40-49 o C) RECOMMENDED SETTING According to manufacturers recommendations Cabinet Temperature Less than 100 o F (38 o C) Membrane Feed Air Pressure psi ( bar) depending on Nitrox O2% Fill Oxygen Analyzer Nitrox Storage Pressure Showing the proper reading for intended fill DO NOT exceed rating of tank or 3600 P.S.I (250 bar) Page 25

26 15.1 Pumping Nitrox (continued) 4) After filling is complete, close cylinder valve, vent the bleed valve, and remove the cylinder. 5) Test the Nitrox %O 2 in the cylinder using an independent Oxygen Analyzer such as the Nuvair O 2 Quickstick TM. Calibrate analyzer before use in accordance with manufacturer s instructions. 6) Repeat steps 1-5 until you have filled all Scuba cylinders. 7) Mark each tank with fill date, %O 2, fill pressure, and MOD (Maximum Operating Depth). 8) Log every Nitrox fill to document the following information: Fill date and time of day Tank Number Supplier s check of oxygen content (%O 2 ) plus signature and date User s check of oxygen content (%O 2 ) plus signature and date Fill Pressure MOD (Maximum Operating Depth) in user s handwriting Nitrox certifying agency and card number 9) When filling a HP Nitrox storage tank, verify that Fill Oxygen Analyzer %O 2 reading equals the desired Nitrox %O 2. Open applicable line valves and tank valve, and fill with Nitrox. Do not exceed rated pressure of cylinder, and do not exceed 3600 P.S.I. (250 bar) under any condition. After filling is complete, close all valves and allow Nitrox System to shut down Pumping Air To use the System to pump air, simply turn off the LP Compressor. No Nitrox will be supplied to the HP Compressor, and it will pump air only. When the HP Compressor is pumping air, the Permeate Oxygen Analyzer and the Fill Oxygen Analyzer should both read 20.9% O 2. Use Independent Oxygen Analyzer for Verification On/Off Switches On/Off Knob for HP Compressor LP Compressor Control Always use Oxygen Analyzers to monitor oxygen content of any gas flowing through the System. Both air and Nitrox are subject to variations in oxygen content Shutting Down 1) When the Storage Banks are finished filling and tank valves are closed, the Nitrox System will automatically shut down at the pressure set on the pressure switch (3600 psi). 2) Manually shut off the Membrane System by turning the Feed Air Regulator adjustment knob CCW to reduce pressure to minimum setting and then turn off the LP & HP compressors. 3) The system will automatically drain all Filter, Compressor, and Volume Tank condensate. Page 26

27 16.0 Nitrox Operation Notes 16.1 Correlation of Feed air Pressure to Oxygen Content After the 10 hour break-in period for your Nitrox System, you will notice that specific Nitrox %O 2 s always match specific feed air pressures once the System has warmed up. These pressures will be repeatable. If you find that the Fill Oxygen Analyzer reads 36% O 2 when the feed air pressure is at 125 P.S.I. (9 bar), record this pressure or make a mark on the feed air pressure gauge indicating the %O 2. Do this for each %O 2 that you normally make, making sure System has warmed up first. The next time Nitrox with 36% O 2 is needed, adjust the regulator to 125 P.S.I. (9 bar) and wait for the Oxygen Analyzer reading to stabilize. You will find the analyzer reading to be very close to 36% O 2, requiring only minor adjustments of the regulator to achieve the exact desired %O 2. Use the Fill Oxygen Analyzer to verify the Nitrox oxygen percentage prior to pumping. When using the feed air pressure reading to obtain specific oxygen percentage, minor adjustments of the feed air pressure regulator may be required to obtain the exact percentage desired Hot Fills While in the process of filling HP Nitrox Storage Tanks, you may have a need to supply a walk-in customer with a Scuba Cylinder fill of a different Nitrox mix. You can change mixes as follows: 1) With the Nitrox System operating, isolate the HP Nitrox Storage Tanks from the HP Compressor by closing the appropriate valves. 2) Record the Membrane System feed air pressure reading. 3) Slightly open fill whip valve on the HP Compressor, and adjust so the running Compressor maintains P.S.I. ( bar) outlet pressure. 4) Adjust the B.P. feed air regulator to the pressure corresponding to the desired Nitrox %O 2 for the Scuba Cylinder fill. 5) Allow the Fill Oxygen Analyzer reading to stabilize, make any minor adjustments necessary to achieve the desired %O 2, and then fill cylinder in normal manner. 6) When finished return regulator to previous setting, and allow the Fill Oxygen Analyzer reading to stabilize. Make any minor adjustments necessary to achieve the desired %O 2, and then resume filling Storage Tanks. Page 27

28 17.0 Maintenance The following list of daily and routine maintenance items is intended as a guide. Refer to LP and HP Compressor manuals for complete maintenance requirements Daily Maintenance Be sure to check Compressor Lubricant levels prior to each day of operation. Failure to ensure the proper lubricant level will lead to system damage. 1) Check lubricant levels of both LP and HP Compressors and add proper lubricants as required. See Section 17.3 and Compressor manuals for details. 2) Slightly open each HP and LP Manual Condensate Drain Valve to verify that no condensate is present. 3) Check LP Air Filtration for condensate and proper operation of condensate drains. Condensate Tank Filter Pressure Drain Use only the specified Nuvair Lubricants in this system. The use of incompatible lubricants presents a risk of fire and/or explosion, and may result in system damage. This can lead to severe personal injury and death. Be sure that all pressure has been relieved from the system prior to opening any filtration canister. Failure to vent pressure from the system prior to opening the canister can lead to serious personal injury or death. If system is located in an area where there is high humidity and high heat, the life of all Filtration Elements may be as little as 35% of rated operating capacity. Check the Compressor manual and Appendix for details on Filter Element Life Factors. Page 28

29 15.1 Routine Maintenance 1) LP Compressor Lubricant: Change Compressor Lubricant every 1000 hours or annually. Only use lubricants rated for use with Nitrox, such as Nuvair 546 TM. Never mix Compressor Lubricants. See Section 17.3 and LP Compressor manual for details. 2) HP Compressor Lubricant: Change Compressor Lubricant every 100 hours or annually, whichever comes first. Only use lubricants rated for use with Nitrox, such as Nuvair 455 TM. Never mix Compressor Lubricants. See Section 17.4 and HP Compressor manual for details. 3) LP Air Filtration Inspection: On a weekly basis, inspect each Filter Bowl for the presence of moisture and each Element for any unusual degradation or wetness. See Section 17.5 for details. Evidence of any moisture in the HF1-20 filter indicates air is not cooling properly. 4) LP Air Filtration Elements: Change LP Filter Elements every 500 hours or annually to maintain CGA Grade D air standards. Visual liquid level and service life indicators assist with monitoring replacement intervals. See Section 17.5 for details. If the Nitrox System is operated in high humidity and/or high temperature, Filter Elements must be changed more often. See Appendix for details on Filter Element Life Factors. 5) HP Compressor Filtration Element: Change HP Filter Element every 60,000 cubic feet of air or Nitrox processing to maintain CGA Grade E air standards. See Section 17.6 for details. If the Nitrox System is operated in high humidity and/or high temperature the Filter Element must be changed more often. See Appendix for details on Filter Element Life Factors. 6) Condensate Drain Container: Check level and drain weekly or as needed. 7) Semi-Permeable Membrane: No maintenance required. Service life exceeds 20 years if LP Air Filtration is properly serviced to maintain Grade D standards. 8) Membrane System Air Intake Filter: Inspect filter element every 3 months for visible particles. Change every 12 months or sooner if particles are visible. 9) Oxygen Analyzers: Replace Oxygen Sensor and Battery as required. See manual included with Nitrox System. Condensate Drain Container. Check & Drain Weekly. 10) Air/Nitrox Quality Analysis: Take breathing air/nitrox samples quarterly for analysis to assure compliance with CGA Grade E breathing air standards. Do not swallow (ingest) either the electrolyte from the Oxygen Sensor or the Sensor itself. The Potassium Hydroxide chemical contained in the Sensor can cause severe injury or death. If electrolyte or the Sensor is swallowed, seek medical attention immediately. If after handling the Oxygen Analyzer or Sensor, you find that your fingers or other parts of your body feel slippery or the skin or eyes sting, immediately flush affected area with clean, fresh water for at least 15 minutes. The stinging or slippery sensation is an indication of a leaking Sensor. The Potassium Hydroxide chemical contained in the Sensor can cause severe injury or death. Seek immediate medical attention if eye contact is made or skin stinging persists. Page 29

30 Use only the specified Nuvair Lubricants in this system. The use of incompatible lubricants presents a risk of fire and/or explosion, and may result in system damage. This can lead to severe personal injury and death Compressor Lubricant ( see page for material spec sheets) The LP Compressor in your Nitrox System comes standard with Nuvair 546 TM Synthetic Food Grade Compressor Lubricant for Rotary Screw Compressors. The HP Compressor comes with the Nuvair 455 Synthetic Food Grade Lubricant. Check lubricant levels at each Sight Gauge and add lubricant as required through the appropriate Fill Plug. Lubricant is removed through the Drain Plugs. See LP and HP Compressor manuals for details on servicing Lubricant Never mix lubricants! Rotary and Reciprocating oil are different! Do not carry out these tasks if the compressor has only just shut down; wait for the compressor to cool. Pressure must be drained before opening LP Fill Plug. Any oil spilt during the oil/filter change could cause personnel to slip; wear protective garments and anti-slip footwear and remove traces of oil immediately. Both oil and filter are classified as special wastes and must therefore be disposed of in compliance with the anti-pollution laws in force. All maintenance work must be carried out with the compressor OFF and the power supply lead unplugged from the main socket. Lubricant Fill Plugs Page 30

31 17.4 LP Feed Air Filtration Special attention needs to be given to the arrangement of the four LP Feed Air Filtration Elements and Bowls. Properly reinstall each Element and Bowl to the correct Housing. Improper sequence can cause damage to downstream components The use of Grade D or better feed air is critical to prevent the passing of any residual oil vapor into the Membrane System. Four stages of Hankison LP filtration are used to produce Grade D air: 1) Coalescing Filter 2) Coalescing & Water/Oil Vapor Removal to 1 Particulate micron 3) Coalescing & Water/Oil Vapor Removal to 0.01 Particulate micron 4) Final Stage - Oil Vapor Removal to PPM LP Filtration Inspection Open each Filter and inspect as follows: 1) Inspect Bowl for the presence of moisture. A high level of moisture build-up in the HF11-20 or HF7-20 Filter indicates improper operation of auto-drain floats. Evidence of any moisture in the HF1=20 Filter indicates air is not cooling properly and moisture is not properly being removed. Excess moisture will prevent the final filter from operating properly and can lead to damage of the membrane. Air Flow Housing Air Flow HF1-20 HF5-20 HF7-20 HF11-20 Oil Coalescing Particle Vapor &Water/Oil & Coalescing Removal Vapor Moisture Removal Removal Replacement Element Part Number E1-20 E5-20 E7-20 E11-20 Bowl Element HF11-20 Filter with Auto-Drain Float & Liquid Level Indicator HF1-20 Filter with Manual Drain Should not Contain Moisture HF5-20Filters with Auto- Drain Float & Liquid Level/ Service Indicators HF7-20 Filter with Auto- Drain Float & Liquid Level Indicator Page 31

32 Changing LP Filtration Elements Change Filter Elements every 500 hours or annually. If the Nitrox System is operated in high humidity and/or high temperature, Filter Elements must be changed more often. See Appendix for details on Filter Element Life Factors. Visual service indicators on the HF5 & HF7 filters assist with monitoring replacement intervals. 1) Push up on Filter Bowl, rotate counter-clockwise, and lower to remove. 2) Gently unscrew Filter Element and pull down off mounting post. 3) Replace Element and reassemble in reverse order. Changing LP Filtration Element The interior of the Filter Bowls can be cleaned with a diluted solution of Simple Green TM and flushed thoroughly with clean water. This will assist to prolong the life of the element, bowl, and auto drain. Page 32

33 17.5 HP Compressor Filtration The HP Compressor comes standard with Triplex filtration, utilizing a single Filter Element. Do NOT use any substitute. Change Filter Element every 60,000 cubic feet of air or Nitrox processing. If the Nitrox System is operated in high humidity and/or high temperature, Filter Element must be changed more often. See Appendix for details on Filter Element Life Factors. 1) Shut down the Nitrox System 2) Open Manual Bleed Drain Valve to drain pressure. Leave Valve open. 3) Unscrew the Filter Canister Cap. 4) Remove expended Element from Filter Canister. 5) Install New Element place pressure on element to seat the element. 6) Reinstall Cap to Canister. 7) Close Manual Condensate Valves. Filter Canister Caps 3 Condensate Tank 4 5 Manual Bleed Drain Valve Page 33

34 17.6 Spare Parts List See LP and HP Compressor manuals for Compressor parts lists. Other Nitrox System components and related items are listed below. Nitrox System Components Type Part Number LP Compressor Consumables Rotary Screw Compressor Nuvair 546, 1 Gal 9409 Lubricant, Food Grade, Nitrox Compatible LP Filtration Element Hankison HF11-20 E11-20 Hankison` HF7-20 E7-20 Hankison HF5-20 E5-20 Hankison HF1-20 E1-20 Oil Filter Rotair S Air/Oil Seperator Rotair S Air Intake Filter Rotair S HP Compressor Consumables HP Compressor Lubricant, Nuvair 455, 1 Gal 9406 Food Grade, Nitrox Compatible HP Compressor Filtration Gas Drying Filter X65677 Element Breathing Air Filter, Grade E X65247 Heater Assembly 1200 Watt, 28" Length H1200 Heater Thermostat Control 220V Fahrenheit Gauge standard TS F TS C Heater Pressure Switch B Membrane 230 Series PPA230 Air Intake Filter Element CFM 18P Analyzers Oxygen Analyzer Pro O Pro O 2 Remote 9462 Oxygen Sensor Pro O 2 Pro O 2 Remote Related Components Air/Nitrox Quality Analysis Kit CGA Grade Required Specify: (1) Single Use or (2) Program Use Page 34

35 17.7 Service Record Log Date Technician Name Service Performed Page 35

36 Appendix Supply and Breathing Air Specifications All supply and breathing air must meet the following requirements of CGA G Supply air delivered to the Membrane System must be purified to meet Grade D or E quality, and periodic air quality testing to assure compliance is recommended. All breathing air for diving produced by the downstream Compressor must be purified to meet Grade E quality, and periodic air quality testing to assure compliance is mandatory. Item Grade D Grade E Oxygen % 20-22% Carbon Dioxide (maximum) 1000 PPM 1000 PPM Carbon Monoxide (maximum) 10 PPM 10 PPM Hydrocarbons (maximum) Not specified 25 PPM Water Vapor (maximum) Not specified Not specified Dew Point (maximum) (1) Not specified Not specified Oil & Particles (maximum) (2) 5 mg/m3 5 mg/m3 Odor None None Notes: (1) Dew Point of supply air must be >10 o F (6 o C) colder than coldest ambient air expected (2) Supply air delivered to the Membrane System must contain <0.003 PPM Oil Vapor All breathing Nitrox produced for diving must be purified to meet these same requirements, except for oxygen content. Nitrox oxygen content must measure within +/- 1% O 2 of the specified value of the mixture using a properly calibrated Oxygen Analyzer (i.e. Nitrox produced with a target content of 32% O 2 must measure in the range of 31-33% O 2 ). Periodic air quality testing to assure compliance is mandatory. Filter Element Life Factors Breathing air filter element life is typically rated by manufacturer based on an air temperature of 80ºF at the filter inlet. Under normal operation this temperature is 12ºF (5ºC) warmer than the ambient air, resulting in an equivalent ambient temperature rating at 68ºF (20ºC). To determine element life at a different ambient temperature, multiply the rated life by the life factor listed below: Filter Temperature Ambient Temperature Filter Element Life Factor 53ºF (12ºC) 41ºF (5ºC) 2.6 x Life 62ºF (17ºC) 50ºF (10ºC) 1.8 x Life 71ºF (23ºC) 59ºF (16ºC) 1.35 x Life 80ºF (27ºC) 68ºF (20ºC) 1 x Life 89ºF (32ºC) 77ºF (25ºC) 0.8 x Life 96ºF (36ºC) 84ºF (29ºC) 0.55 x Life 105ºF (41ºC) 93ºF (34ºC) 0.45 x Life 114ºF (46ºC) 102ºF (39ºC) 0.35 x Life Page 36

37 Effective Date: 03/19/2010 Material Safety Data Sheets Nuvair 455 Premium Synthetic Food Grade Air/Nitrox Compressor Lubricant Voyager III TM Nitrox System I. Product Identification: Trade Name:. Nuvair 455 Chemical Name:... Polyalphaolefin Chemical Family:..... Synthetic hydrocarbons/esters II. Components & Hazard Statement: This product is non-hazardous. This material is not considered hazardous by the OHSA Hazard Communication Standard (29 CFR ). III. Physical Data: Viscosity: C Specific Gravity (Water = 1.0): Boiling Point:... N.A. Vapor Pressure:... Negligible Appearance & Odor:... Clear with Mild odor Solubility in Water:... Negligible IV. Fire & Explosion Hazard Data: Flash point: F / 24 0C/ COC Autoignition Temperature:... Not Established Flammability Limits:... Not Established Extinguishing Media:... Dry Chemical; CO2 Foam; Water Spray Special Fire Fighting Procedure:.. Burning may produce irritating/noxious fumes. Firefighters should use NIOSH/MNSA approved self-contained breathing apparatus. Use water to cool fire-exposed containers to prevent pressure build-up. V. Reactivity Data: Stability:.... This product is stable and will not react with water. Materials to Avoid:... Avoid strong oxidizers Hazardous Decomposition Products:... Carbon monoxide, Carbon dioxide VI. Health Information: Eye Contact:... Flush eyes with water for 15 minutes. Call physician if irritation develops. Skin Contact:... Wash skin with soap and water. Inhalation:... Remove to fresh air. Ingestion:... First aid not normally required. If uncomfortable, call physician. VII. Health Hazard Data: Exposure Limit:... Not Applicable Effects of Overexposure:. Low oral and dermal toxicity. Prolonged or repeated exposure may cause irritation, nausea, and vomiting. VIII. Employee Protection: For general personal hygiene, wash hands thoroughly after handling material. Avoid contact with skin and eyes. Chemical impervious gloves are not required, but may be recommended for prolonged exposure. Use in a well ventilated area. IX. Storage, Spill, & Disposal Procedures: Storage:. Store in clean, dry area. Spills:. Use absorbent materials to soak up fluid. Disposal: Incinerate this product and all associated wastes in a licensed facility in accordance with Federal, state, and local regulations. X. Hazard Rating Information: NFPA Health:.. 0 Flammability:... 1 Reactivity: Personal Protection:.. B This information contained herein is based on the data available to us and is believed to be true and accurate. Nuvair makes no warranty, expressed or implied, regarding the accuracy of this data or the results to be obtained from the use thereof. Nuvair assumes no responsibility for injury from the use of this product. Page 37

38 Material Safety Data Sheet Nuvair 751 Premium Synthetic Diester Based Air/Nitrox Compressor Lubricant Effective Date: 3/10/2010 Supersedes: I. Product Identification: Trade Name: Nuvair 751 Chemical Name:.. Diester Chemical Family:. Diester II. Components & Hazard Statement: This product is non-hazardous. This material is not considered hazardous by the OHSA Hazard Communication Standard (29 CFR ). III. Physical Data: Viscosity: C Specific Gravity (Water = 1.0): Boiling Point:... Not determined Vapor Pressure:... Negligible Appearance & Odor:... Amber / Mild odor Solubility in Water:... Negligible Other Data:... Non-toxic USDA H-2 approved IV. Fire & Explosion Hazard Data: Flash point: F / 271 C COC ASTM D-92 Autoignition Temperature: F ASTM D-2155 Flammability Limits:... Not Established Extinguishing Media:... Dry Chemical; CO2 Foam; Water Spray Special Fire Fighting Procedure:.. Burning may produce irritating/noxious fumes. Firefighters should use NIOSH/MNSA approved self-contained breathing apparatus. Use water to cool fire-exposed containers to prevent pressure build-up. V. Reactivity Data: Stability:.... Stable under normal conditions. Materials to Avoid:... Incompatible with oxidizing agents. Hazardous Decomposition Products:... Carbon monoxide, Carbon dioxide VI. Health Information: Eye Contact:... Flush eyes with water for 15 minutes. Call physician if irritation develops. Skin Contact:... Wash skin with soap and water. Inhalation:... Remove to fresh air. Ingestion:... First aid not normally required. If uncomfortable, call physician. VII. Health Hazard Data: Exposure Limit:... Not Applicable Effects of Overexposure:. Low oral and dermal toxicity. Prolonged or repeated exposure may cause irritation, nausea, and vomiting. VIII. Employee Protection: For general personal hygiene, wash hands thoroughly after handling material. Avoid contact with skin and eyes. Chemical impervious gloves are not required, but may be recommended for prolonged exposure. Use in a well ventilated area. IX. Storage, Spill, & Disposal Procedures: Storage:. Store in clean, dry area. Spills:. Use absorbent materials to soak up fluid. Disposal: Incinerate this product and all associated wastes in a licensed facility in accordance with Federal, state, and local regulations. X. Hazard Rating Information: NFPA Health:.. 0 Flammability:... 1 Reactivity: Personal Protection:.. B This information contained herein is based on the data available to us and is believed to be true and accurate. Nuvair makes no warranty, expressed or implied, regarding the accuracy of this data or the results to be obtained from the use thereof. Nuvair assumes no responsibility for injury from the use of this product. Page 38

39 Effective Date: 03/19/2010 Supersedes: Material Safety Data Sheet Nuvair 546 Premium Synthetic Food Grade Air/Nitrox Compressor Lubricant Voyager III TM Nitrox System I. Product Identification: Trade Name:. Nuvair 546 Chemical Name:... Polyalphaolefin Chemical Family:..... Synthetic hydrocarbon II. Components & Hazard Statement: This product is non-hazardous. This material is not considered hazardous by the OHSA Hazard Communication Standard (29 CFR ) III. Physical Data: Viscosity: C Specific Gravity (Water = 1.0): Boiling Point:... Not Determined Vapor Pressure:... Negligible Appearance & Odor:... Clear & odor Mild Solubility in Water:... Negligible Other Data:... Non-Toxic USDA H-1 Approved IV. Fire & Explosion Hazard Data: Flash point: F / 260 C Autoignition Temperature:... Not Determined Flammability Limits:... Not Determined Extinguishing Media:... Dry Chemical; CO2 Foam; Water Spray Special Fire Fighting Procedure:.. Burning may produce irritating/noxious fumes. Firefighters should use NIOSH/MNSA approved self-contained breathing apparatus. Use water to cool fire-exposed containers to prevent pressure build-up. V. Reactivity Data: Stability:.... Stable under normal conditions. Materials to Avoid:... Incompatible with oxidizing agents. Hazardous Decomposition Products:... Carbon monoxide, Carbon dioxide VI. Health Information: Eye Contact:... Flush eyes with water for 15 minutes. Call physician if irritation develops. Skin Contact:... Wash skin with soap and water. Inhalation:... Remove to fresh air. Ingestion:... First aid not normally required. If uncomfortable, call physician. VII. Health Hazard Data: Exposure Limit:... Not Applicable Effects of Overexposure:. Low oral and dermal toxicity. Prolonged or repeated exposure may cause irritation, nausea, and vomiting. VIII. Employee Protection: For general personal hygiene, wash hands thoroughly after handling material. Avoid contact with skin and eyes. Chemical impervious gloves are not required, but may be recommended for prolonged exposure. Use in a well ventilated area. IX. Storage, Spill, & Disposal Procedures: Storage:. Store in clean, dry area. Spills:. Use absorbent materials to soak up fluid. Disposal: Incinerate this product and all associated wastes in a licensed facility in accordance with Federal, state, and local regulations. X. Hazard Rating Information: NFPA Health:.. 0 Flammability:... 1 Reactivity: Personal Protection:.. B This information contained herein is based on the data available to us and is believed to be true and accurate. Nuvair makes no warranty, expressed or implied, regarding the accuracy of this data or the results to be obtained from the use thereof. Nuvair assumes no responsibility for injury from the use of this product. Page 39

40 OWNER S WARRANTY RESPONSIBILITIES Voyager III TM Nitrox System Failure of the owner to prevent equipment damage by complying with the procedures outlined below and in the Operation Manual will void the Nitrox System warranty. Installation: All set up requirements and procedures provided in the Nitrox System Operation Manual must be followed in their entirety including supply air cleanliness, Compressor preparation, and installation of the Nitrox System. Supply air to the Membrane must be properly filtered to CGA Grade D air quality or better to prevent damage to the Membrane. Air quality testing of the supply air should be performed periodically and documented to assure compliance. If there is any doubt regarding the suitability of a HP or LP Compressor for compressing Nitrox, contact Nuvair or the Compressor manufacturer before you connect your Nitrox System. If an existing HP or LP Compressor is to be used for compressing Nitrox, all traces of the old lubricant must be removed and replaced with a Nitrox Compressor Lubricant approved by Nuvair. Electrical wiring and connections should be made by a qualified electrician in accordance with all national and local electrical codes. Do not change the temperature setting on the Heater Thermostat Control. Changes in temperature settings may cause Membrane damage. To prevent Compressor damage, only use the Compressor Intake Hose provided. If a longer hose is required, contact Nuvair for assistance. Compressors must be provided adequate ventilation to operate properly and prevent heat damage. This requires an ambient temperature below 100 o F (38 o C), sufficient clearance from adjacent walls, and proper rotation direction. Operation: Do not use the Nitrox System to supply a HP or LP Compressor with Nitrox mixtures containing more than 40% oxygen. Compressing higher concentrations of oxygen may cause severe Compressor damage. Do not pump Nitrox mixtures at pressures above the Compressor manufacturer s rating, and never above 3600 P.S.I. (250 bar). Compressing Nitrox at higher pressures may cause severe HP Compressor damage. To prevent Membrane damage, drain all low pressure filter and volume tank condensate on a daily basis. If you become aware of an operational fault, stop using the equipment immediately and contact Nuvair for assistance. Maintenance: Change low pressure filter elements on a schedule determined by filter capacity and ambient temperature and humidity. Contact Nuvair if you need assistance establishing a schedule for your equipment and location. Replace Membrane System Air Intake Filter on a regular basis to prevent flow obstruction. Keep all nuts, bolts, fittings, connectors, and clamps tight. Keep a service record book showing that regular maintenance work has been carried out. If a warranty claim becomes necessary, it will aid in demonstrating that damage has not been caused by insufficient maintenance. Proof of maintenance may be required prior to determining the validity of a warranty request. Page 40

41 NITROX SYSTEM WARRANTY Voyager III TM Nitrox System extends a limited warranty, which warrants the Nitrox System to be free from defects in materials and workmanship under normal use and service for a limited period. The specific Membrane Component of the Nitrox System is warranted according to the pro-rated terms as set forth below. All other Original Equipment Manufacturer (OEM) components used in the system are warranted only to the extent of the OEM s warranty to. makes no warranty with respect to these OEM components, and only warrants the workmanship that has employed in the installation or use of any OEM component. This warranty is not transferable. will, at it s discretion and according to the terms as set forth within, replace or repair any materials which fail under normal use and service and do not exhibit any signs of improper maintenance, misuse, accident, alteration, weather damage, tampering, or use for any other than the intended purpose. Determination of failure is the responsibility of, which will work together with the customer to adequately address warranty issues. When any materials are repaired or replaced during the warranty period, they are warranted only for the remainder of the original warranty period. This warranty shall be void and shall have no responsibility to repair or replace damaged materials resulting directly or indirectly from the use of repair or replacement parts not approved by. Pro-Rated Terms: warrants the Membrane Component of the Nitrox System to be free from defects in material and workmanship for a period of thirty-six (36) months from date of installation or forty-two (42) months from date of shipment by, whichever may occur first. The warranty covers parts only and is prorated as follows: First Year Repair or replacement free of charge Second Year Warranty allowance of 70% of the current Membrane Component list price Third Year Warranty allowance of 40% of the current Membrane Component list price A warranty registration card, supplied with system documentation, must be filled out and submitted to for the warranty to be in full effect. If the warranty registration card is not received within thirty (30) days of installation, the thirty-six (36) month warranty will begin with the date of shipment from. For warranty service to be considered, customer s account must be current or paid in full. Maintenance Items: Any materials which are consumed, or otherwise rendered not warrantable due to processes applied to them, are considered expendable and are not covered under the terms of this policy. This includes maintenance and consumable items listed as part of a suggested maintenance program included with system documentation. Return Policy: Application for warranty service can be made by contacting during regular business hours and requesting a Return Material Authorization number. Materials that are found to be defective must be shipped, freight pre-paid, to the office in Oxnard, California. Upon inspection and determination of failure, shall exercise its options under the terms of this policy. Warranty serviced materials will be returned to the customer via s preferred shipping method, at s expense. Any expedited return shipping arrangements to be made at customer s expense must be specified in advance. Limitation of Warranty and Liability: Repair, replacement or refund in the manner and within the time provided shall constitute S sole liability and the Purchaser s exclusive remedy resulting from any nonconformity or defect. shall not in any event be liable for any damages, whether based on contract, warranty, negligence, strict liability or otherwise, including without limitation any consequential, incidental or special damages, arising with respect to the equipment or its failure to operate, even if has been advised of the possibility thereof. makes no other warranty or representation of any kind, except that of title, and all other warranties, express or implied, including warranties of merchantability and fitness for a particular purpose, are hereby expressly disclaimed. No salesman or other representative of has authority to make any warranties. Page 41

42 Notes:

43

44 Nuvair Phone Fax Beacon Place Oxnard, CA Web: Revision 03.15

Operation Manual. Voyager TM. Nitrox System

Operation Manual. Voyager TM. Nitrox System Operation Manual Voyager TM Nitrox System If you have any questions on this equipment please contact Technical Support at: Nuvair 1600 Beacon Place Oxnard, CA 93033 Phone: 1-805-815-4044 FAX: 1-805-486-0900

More information

User Manual. Voyager II & Open Voyager II. Nitrox System Rev 03.19

User Manual. Voyager II & Open Voyager II. Nitrox System Rev 03.19 User Manual Voyager II & Open Voyager II Nitrox System Rev 03.19 If you have any questions on this equipment please contact Technical Support at: Nuvair 1600 Beacon Place Oxnard, CA 93033 Phone: +1 805

More information

Operation Manual. Element HP TM. Open Model Nitrox System

Operation Manual. Element HP TM. Open Model Nitrox System Operation Manual Element HP TM Open Model Nitrox System If you have any questions on this equipment please contact Technical Support at: Nuvair 1600 Beacon Place Oxnard, CA 93033 Phone: +1 805 815 4044

More information

Operation Manual. MCH 36D Nitrox System

Operation Manual. MCH 36D Nitrox System Operation Manual MCH 36D Nitrox System If you have any questions on this equipment please contact Technical Support at: Nuvair 1600 Beacon Place Oxnard, CA 93033 Phone: +1 805 815 4044 FAX: +1 805 486

More information

LP300 EK76 Air Cooled Marine Nitrox Generator

LP300 EK76 Air Cooled Marine Nitrox Generator User Manual LP300 EK76 Air Cooled Marine Nitrox Generator Rev 08.18 2 LP300 EK76 Air Cooled Marine Nitrox Generator If you have any questions on this equipment please contact Technical Support at: Nuvair

More information

Operation Manual. Nitrox System Rev Element LP TM Nitrox System

Operation Manual. Nitrox System Rev Element LP TM Nitrox System Operation Manual Element LP TM Nitrox System Rev 02.16 Element LP TM Nitrox System If you have any questions on this equipment please contact Technical Support at: Nuvair 1600 Beacon Place Oxnard, CA 93036

More information

Operation Manual. LP 280 Nitrox Generator With Nitrox Manager. Rotair RVG Version

Operation Manual. LP 280 Nitrox Generator With Nitrox Manager. Rotair RVG Version Operation Manual LP 280 Nitrox Generator With Nitrox Manager Rotair RVG Version If you have any questions on this equipment please contact Technical Support at: Nuvair 1600 Beacon Place Oxnard, CA 93033

More information

User Manual Nuvair LP280 EK76 Nitrox Generator Rev 08.18

User Manual Nuvair LP280 EK76 Nitrox Generator Rev 08.18 User Manual Nuvair LP280 EK76 Nitrox Generator Rev 08.18 If you have any questions on this equipment please contact Technical Support at: Nuvair 1600 Beacon Place Oxnard, CA 93033 Phone: +1 805 815 4044

More information

User Manual Nitrox Membrane System

User Manual Nitrox Membrane System User Manual Nitrox Membrane System 215, 230 & 250 Series Rated for 6 CFM, 10 CFM, 16 CFM, 20 CFM, 32 CFM and 50 CFM Low Pressure Supply Option High Pressure Supply Option This Operation Manual contains

More information

Operation Manual. LP 500D Nitrox Generator. Rotair Version

Operation Manual. LP 500D Nitrox Generator. Rotair Version Operation Manual LP 500D Nitrox Generator Rotair Version If you have any questions on this equipment please contact Technical Support at: Nuvair 1600 Beacon Place Oxnard, CA 93033 Phone: +1 805 815 4044

More information

Operation Manual. LP 280 Nitrox Generator TM Gardner Denver/Bottarini Version

Operation Manual. LP 280 Nitrox Generator TM Gardner Denver/Bottarini Version Operation Manual LP 280 Nitrox Generator TM Gardner Denver/Bottarini Version If you have any questions on this equipment please contact Technical Support at: Nuvair 2949 West 5 th St. Oxnard, CA 93030

More information

Operation Manual. RVK>Q325 LP 28.5hp Diesel or Electric Nitrox System

Operation Manual. RVK>Q325 LP 28.5hp Diesel or Electric Nitrox System Operation Manual RVK>Q325 LP 28.5hp Diesel or Electric Nitrox System 02062013 www.nuvair.com If you have any questions on this equipment please contact Technical Support at: Nuvair 2949 West 5 th St. Oxnard,

More information

User Manual. Nuvair Q-325 (Also Operation and Maintenance for Q-370) Diesel and Electric rev

User Manual. Nuvair Q-325 (Also Operation and Maintenance for Q-370) Diesel and Electric rev User Manual Q-325 (Also Operation and Maintenance for Q-370) Diesel and Electric rev. 12.18 Q-325 If you have any questions on this equipment please contact Technical Support at: 1600 Beacon Place Oxnard,

More information

Operation Manual. O2 Quickstick. Oxygen Analyzer 08.17

Operation Manual. O2 Quickstick. Oxygen Analyzer 08.17 Operation Manual O2 Quickstick Oxygen Analyzer 08.17 If you have any questions on this equipment please contact Technical Support at: Nuvair 1600 Beacon Place Oxnard, CA 93033 Phone: 805-815-4044 FAX:

More information

OPERATION MANUAL NTF-15

OPERATION MANUAL NTF-15 OPERATION MANUAL NTF-15 Nitrogen Tire Filling Valve Stem Caps (Qty=200) Order P/N 436075 RTI Technologies, Inc 10 Innovation Drive York, PA 17402 800-468-2321 www.rtitech.com 035-81235-00 (Rev B) TABLE

More information

Operation Manual. O2 Quickstick. Oxygen Analyzer

Operation Manual. O2 Quickstick. Oxygen Analyzer Operation Manual O2 Quickstick Oxygen Analyzer 01.11 www.nuvair.com If you have any questions on this equipment please contact Technical Support at: Nuvair 2949 West 5 th St. Oxnard, CA 93030 Phone: 805-815-4044

More information

OPERATION MANUAL NTF-60 Plus

OPERATION MANUAL NTF-60 Plus OPERATION MANUAL NTF-60 Plus Nitrogen Tire Filling Valve Stem Caps (Qty=200) Order P/N 436075 RTI Technologies, Inc 10 Innovation Drive York, PA 17402 800-468-2321 www.rtitech.com 035-81264-00 (Rev A)

More information

Operation Manual. Nuvair Q-325 (Also Operation and Maintence for Q-370) Diesel and Electric rev

Operation Manual. Nuvair Q-325 (Also Operation and Maintence for Q-370) Diesel and Electric rev Operation Manual Nuvair Q-325 (Also Operation and Maintence for Q-370) Diesel and Electric rev. 03.15 If you have any questions on this equipment please contact Technical Support at: Nuvair 1600 Beacon

More information

Brownie s. Commercial Series NMCS-30 NMCS NW 1st Street, Fort Lauderdale, FL PH Fx

Brownie s. Commercial Series NMCS-30 NMCS NW 1st Street, Fort Lauderdale, FL PH Fx Brownie s M A R I N E G R O U P Commercial Series NMCS-7.5 NMCS-10 NMCS-20 NMCS-30 940 NW 1st Street, Fort Lauderdale, FL 33311 PH. 954.462.5570 Fx. 954.462.6115 This information is believed to be accurate

More information

Operation Manual. Pro CO. Carbon Monoxide Analyzer. Rev

Operation Manual. Pro CO. Carbon Monoxide Analyzer. Rev Operation Manual Pro CO Carbon Monoxide Analyzer Rev. 10.17 Quick Reference Guide READ ENTIRE MANUAL BEFORE USE 1. To switch on, hold the On/Off button until the display powers up. 2. To turn off, hold

More information

Operation Manual. Pro O 2 Pro O 2 Remote. Oxygen Analyzers. Rev 08.17

Operation Manual. Pro O 2 Pro O 2 Remote. Oxygen Analyzers. Rev 08.17 Operation Manual Pro O 2 Pro O 2 Remote Oxygen Analyzers Rev 08.17 If you have any questions on this equipment please contact Technical Support at: Nuvair 1600 Beacon Place Oxnard, CA 93033 Phone: 1-805-815-4044

More information

Operation Manual. Pro CO Analyzer TM. Pro CO with High Temp Alarm Carbon Monoxide Analyzer

Operation Manual. Pro CO Analyzer TM. Pro CO with High Temp Alarm Carbon Monoxide Analyzer Operation Manual Pro CO Analyzer TM & Pro CO with High Temp Alarm Carbon Monoxide Analyzer 02.1.12 If you have any questions on this equipment please contact Technical Support at: Nuvair 2949 West 5 th

More information

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST OIL-LESS TYPE IMPORTANT: PLEASE READ CAREFULLY BEFORE STARTING OPERATIONS. THE CONTENTS ARE FOR GENERAL INFORMATION OF ALL THE SIMILAR MODELS. Record

More information

Operation Manual. Pro He Alarm TM. Helium Analyzer. Rev 08.17

Operation Manual. Pro He Alarm TM. Helium Analyzer. Rev 08.17 Operation Manual Pro He Alarm TM Helium Analyzer Rev 08.17 If you have any questions on this equipment please contact Technical Support at: Nuvair 1600 Beacon Place Oxnard, CA 93033 Phone: 805-815-4044

More information

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289 3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS Item #31289 The EASTWOOD 3 GALLON, OILLESS PANCAKE COMPRESSOR, with an Integral Air Regulator, efficiently supplies all compressed air requirements for

More information

Operating Manual. Model BAC-30RT30/BAC-30DC

Operating Manual. Model BAC-30RT30/BAC-30DC Model BAC-30RT30/BAC-30DC Manual No. BAC012 (Rev 1 October 2002) Operating Manual AIR SYSTEMS INTERNATIONAL, INC. 829 Juniper Crescent, Chesapeake, Va., 23320 Telephone (757) 424-3967 Toll Free 1-800-866-8100

More information

Technical Information

Technical Information Technical Information Installation, Operation, Installation, Operation and Maintenance and Maintenance Manual Manual Balston Model 75700-K728 Nitrogen Generator Figure 1-75700-K728 Overall Dimensions These

More information

PremAire INSTRUCTIONS FOR VORTEX TUBE MODE OF OPERATION

PremAire INSTRUCTIONS FOR VORTEX TUBE MODE OF OPERATION DUAL SUPPLY REGULATOR ESCAPE CYLINDER VORTEX MAIN INLET PremAire INSTRUCTIONS FOR VORTEX TUBE MODE OF OPERATION WARNING THIS MANUAL MUST BE READ CAREFULLY BY ALL PERSONS WHO HAVE OR WILL HAVE THE RESPONSIBILITY

More information

MODEL NUMBER: PSI AIR SOURCE KIT 200 PSI Compressor on 2.0 Gallon 200 PSI Air Tank

MODEL NUMBER: PSI AIR SOURCE KIT 200 PSI Compressor on 2.0 Gallon 200 PSI Air Tank IMPORTANT SAFETY INSTRUCTIONS CAUTION - To reduce risk of electrical shock or Electrocution: MODEL NUMBER: 20008 200 PSI AIR SOURCE KIT 200 PSI Compressor on 2.0 Gallon 200 PSI Air Tank IMPORTANT: It is

More information

Operation Manual. Pro CO O 2 Alarm. Carbon Monoxide and Oxygen Analyzer. Rev

Operation Manual. Pro CO O 2 Alarm. Carbon Monoxide and Oxygen Analyzer. Rev Operation Manual Pro CO O 2 Alarm Carbon Monoxide and Oxygen Analyzer Rev. 08.17 Quick Reference Guide for CO Analyzer READ ENTIRE MANUAL BEFORE USE 1. To switch on, hold the On/Off button until the display

More information

MODEL NUMBER: M20005 AIR SOURCE KIT. 30% Duty Compressor on. 2.0 Gallon Air Tank SAVE THIS MANUAL FOR FUTURE REFERENCE

MODEL NUMBER: M20005 AIR SOURCE KIT. 30% Duty Compressor on. 2.0 Gallon Air Tank SAVE THIS MANUAL FOR FUTURE REFERENCE MODEL NUMBER: M20005 AIR SOURCE KIT 30% Duty Compressor on 2.0 Gallon Air Tank SAVE THIS MANUAL FOR FUTURE REFERENCE USER MANUAL IMPORTANT SAFETY INSTRUCTIONS CAUTION - To reduce risk of electrical shock

More information

Operation Manual. Pro CO 2 Analyzer. Carbon Dioxide Analyzer. Rev

Operation Manual. Pro CO 2 Analyzer. Carbon Dioxide Analyzer. Rev Operation Manual Pro CO 2 Analyzer Carbon Dioxide Analyzer Rev. 10.17 Quick Reference Guide READ ENTIRE MANUAL BEFORE USE 1. To switch on, hold the On/Off button until the display powers up. 2. To turn

More information

User Manual. Pro CO LP Alarm. Carbon Monoxide Analyzer and Low Pressure Monitor with Alarm REV: 03.19

User Manual. Pro CO LP Alarm. Carbon Monoxide Analyzer and Low Pressure Monitor with Alarm REV: 03.19 User Manual Pro CO LP Alarm Carbon Monoxide Analyzer and Low Pressure Monitor with Alarm REV: 03.19 Quick Reference Guide READ ENTIRE MANUAL BEFORE USE 1. To switch on, hold the On/Off button until the

More information

200 PSI FAST-FILL AIR SOURCE KIT

200 PSI FAST-FILL AIR SOURCE KIT 200 PSI FAST-FILL AIR SOURCE KIT 55% Duty Compressor on 2.0 Gallon Air Tank PART NO. 20007 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of

More information

Installation, Operation, and Maintenance Manual Parker Balston Model N2-04 Nitrogen Generator

Installation, Operation, and Maintenance Manual Parker Balston Model N2-04 Nitrogen Generator Installation, Operation, and Maintenance Manual Parker Balston Figure 1 - N2-04 Nitrogen Generator These instructions must be thoroughly read and understood before installing and operating this product.

More information

200 PSI HIGH-FLOW AIR SOURCE KIT

200 PSI HIGH-FLOW AIR SOURCE KIT 200 PSI HIGH-FLOW AIR SOURCE KIT 50% Duty Compressor on 2.0 Gallon Air Tank PART NO. 20008 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of

More information

Operation Manual. Pro 4 Warn Analyzer TM Rev 08.17

Operation Manual. Pro 4 Warn Analyzer TM Rev 08.17 Operation Manual Pro 4 Warn Analyzer TM Rev 08.17 If you have any questions on this equipment please contact Technical Support at: Nuvair 1600 Beacon Place Oxnard, CA 93033 Phone: 805-815-4044 FAX: 805-486-0900

More information

SERVICE MANUAL MODEL BA600AMST-S1 BREATHING AIR PANEL

SERVICE MANUAL MODEL BA600AMST-S1 BREATHING AIR PANEL SERVICE MANUAL MODEL BA600AMST-S1 BREATHING AIR PANEL WARNING: Do not attempt to operate this equipment without first reading and understanding the service manual enclosed with this device. 2/05 GENERAL

More information

User Manual Open Horizontal Electric MCH22 Open Horizontal Electric MCH30 Open Horizontal Electric MCH36 & Open Vertical Electric MCH22 Open Vertical

User Manual Open Horizontal Electric MCH22 Open Horizontal Electric MCH30 Open Horizontal Electric MCH36 & Open Vertical Electric MCH22 Open Vertical User Manual Open Horizontal Electric MCH22 Open Horizontal Electric MCH30 Open Horizontal Electric MCH36 & Open Vertical Electric MCH22 Open Vertical Electric MCH30 Open Vertical Electric MCH36 Rev. 03.19

More information

AC1810 / AC1810-A TECHNICAL SPECIFICATIONS. Operating Pressure psi ( kgs/cm²) [AC1810] Displacement. Net Weight

AC1810 / AC1810-A TECHNICAL SPECIFICATIONS. Operating Pressure psi ( kgs/cm²) [AC1810] Displacement. Net Weight Technical Specifications Operating Instructions Maintenance Information Troubleshooting Guide Parts Diagrams AC1810 / AC1810-A THE EVOLUTION OF PERFECTION CAUTION: Before attempting to use or service this

More information

SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER

SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER SUPPLIMENT TO eom IMPORTANT READ THIS MANUAL BEFORE PRODUCT INSTALLATION, OPERATION, INSPECTION & MAINTENANCE Tougher and more rigid guidelines are being established

More information

Portable Oil Lube Air Compressors

Portable Oil Lube Air Compressors Portable Oil Lube Air Compressors 8003631 8003632 0410149 8018968 8018940 Owner s Manual Read and understand operating instructions before use Safety definitions The information listed below should be

More information

100C Air Compressor Kit

100C Air Compressor Kit 10010 100C Air Compressor (standard mounting bracket, CE Spec) 10014 100C Air Compressor (no leader hose or check valve, CE Spec) 10016 100C Air Compressor (with Omega Bracket, CE Spec) IMPORTANT: It is

More information

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1.

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1. 2 GALLON TWIN STACK AIR COMPRESSOR Model: 9526 DO NOT RETURN TO STORE. Please CALL 800-348-5004 for parts and service. CALIFORNIA PROPOSITION 65 WARNING: You can create dust when you cut, sand, drill or

More information

42045 Heavy Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor Only) Heavy Duty ADA Base Model Kit: 110/145 PSI (ADA Compressor Only)

42045 Heavy Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor Only) Heavy Duty ADA Base Model Kit: 110/145 PSI (ADA Compressor Only) 42045 Heavy Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor Only) 42047 Heavy Duty ADA Base Model Kit: 110/145 PSI (ADA Compressor Only) 45052 Constant Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor

More information

200 PSI COMPRESSORS - MODEL NUMBERS

200 PSI COMPRESSORS - MODEL NUMBERS 200 PSI COMPRESSORS - MODEL NUMBERS 380C AIR COMPRESSOR KIT PART NO. 38033 480C AIR COMPRESSOR KIT PART NO. 48043 380C 480C IMPORTANT: It is essential that you and any other operator of this product read

More information

AIR COMPRESSOR. Failure to follow all instructions as listed below may result in electrical shock, fire, and/or serious personal injury.

AIR COMPRESSOR. Failure to follow all instructions as listed below may result in electrical shock, fire, and/or serious personal injury. 2 GALLON AIR COMPRESSOR Model: 7517 DO NOT RETURN TO STORE. Please CALL 800-348-5004 for parts and service. CALIFORNIA PROPOSITION 65 WARNING: You can create dust when you cut, sand, drill or grind materials

More information

EGL-12 OIL-LESS COMPRESSOR

EGL-12 OIL-LESS COMPRESSOR Operator s Manual 2016 EGL-12 OIL-LESS COMPRESSOR EGL-12 / 2HP OIL-LESS COMPRESSOR INSTALLATION QUESTIONS? 1-800-240-5677 SIERRA DENTAL PRODUCTS, LLC. 1953 W. Gulf to Lake Hwy. Lecanto, FL 34461 www.dentalvacuums.com

More information

Budget Range Operators Handbook

Budget Range Operators Handbook Budget Range Operators Handbook BAMBI AIR COMPRESSORS LTD 152 Thimble Mill Lane Heartlands Birmingham B7 5HT United Kingdom Tel: 0121 322 2299 Fax: 0121 322 2297 Email: sales@bambi-air.co.uk www.bambi-air.co.uk

More information

NTF-230 OPERATION MANUAL

NTF-230 OPERATION MANUAL NTF-230 OPERATION MANUAL MAHLE Aftermarket Inc., Service Solutions 10 Innovation Drive York, Pennsylvania 17402 USA Phone: 717-840-0678 Toll Free: 800-468-2321 Web-site: www.servicesolutions.mahle.com

More information

2 GALLON TWIN STACK AIR COMPRESSOR W/ HOSE REEL

2 GALLON TWIN STACK AIR COMPRESSOR W/ HOSE REEL 2 GALLON TWIN STACK AIR COMPRESSOR W/ HOSE REEL Model: 52024 CALIFORNIA PROPOSITION 65 WARNING: You can create dust when you cut, sand, drill or grind materials such as wood, paint, metal, concrete, cement,

More information

TECHNICAL INFORMATION

TECHNICAL INFORMATION TECHNICAL INFORMATION Installation, Operation, and Maintenance Balston Model 75-77 Nitrogen Generator Figure 1-75-77 Overall Dimensions These instructions must be thoroughly read and understood before

More information

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO 97C COMPRESSOR KIT 12V PART NO. 00097 97C COMPRESSOR KIT 24V PART NO. 02497 98C COMPRESSOR KIT PART NO. 00098 97C 98C IMPORTANT: It is essential that you and any other operator of this product read and

More information

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO 420C AIR COMPRESSOR KIT PART NO. 42042 460C AIR COMPRESSOR KIT PART NO. 46043 420C 460C IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this

More information

TECHNICAL INFORMATION

TECHNICAL INFORMATION TECHNICAL INFORMATION Installation, Operation, and Maintenance Balston 75-96 and 75-98 Nitrogen Generation System Tower Pressure Gauge 5'-1" 3'-6" 7'-4" 6'-10 1/2" PLAN VIEW Figure 1 - Balston 75-96 and

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS MODEL GS2000 / GS2001 OIL-LESS REFRIGERANT RECOVERY UNIT NATIONAL REFRIGERATION PRODUCTS 985 WHEELER WAY LANGHORNE, PA 19047 (215) 638-8909 FAX (215) 638-9270 R01099 GS2000.DOC NRP-OM-GS2000

More information

450P AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES

450P AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES EXTREME SERIES PART NO. 45043 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual before installing and using this product. SAVE THIS

More information

IMPORTANT SAFETY INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS CAUTION - To reduce risk of electrical shock: - Do not disassemble. Do not attempt repairs or modifications. Refer to qualified service agencies for all service and repairs.

More information

INSTRUCTION MANUAL MST AFTERCOOLER SYSTEM MODEL

INSTRUCTION MANUAL MST AFTERCOOLER SYSTEM MODEL INSTRUCTION MANUAL MST AFTERCOOLER SYSTEM MODEL 8059601 To be used with MST Model 8050501 Ambient Air Pump 7/12/05 2 TABLE OF CONTENTS GENERAL INFORMATION... 3 WARNING...4,5 UNPACKING AND AFTERCOOLER ASSEMBLY

More information

Compressors for Paintball and Air Guns Catalog. The most convenient, efficient and effective way to fill your high pressure tanks.

Compressors for Paintball and Air Guns Catalog. The most convenient, efficient and effective way to fill your high pressure tanks. Compressors for Paintball and Air Guns Catalog The most convenient, efficient and effective way to fill your high pressure tanks. Rev. 0.19 TABLE OF CONTENTS Ordering... 1 High Pressure Compressors Coltri

More information

Operation Manual. Pro O 2 Alarm TM. Oxygen Analyzer. Rev

Operation Manual. Pro O 2 Alarm TM. Oxygen Analyzer. Rev Operation Manual Pro O 2 Alarm TM Oxygen Analyzer Rev. 08.17 If you have any questions on this equipment please contact Technical Support at: Nuvair 1600 Beacon Place Oxnard, CA 93033 Phone: 805-815-4044

More information

444C DUAL PERFORMANCE VALUE PACK

444C DUAL PERFORMANCE VALUE PACK (Chrome) PART NO. 44432 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual before installing and using this product. SAVE THIS MANUAL

More information

1020 Industrial Drive, Orlinda, TN fax

1020 Industrial Drive, Orlinda, TN fax Operation Manual Tank Distribution System A-UPT Series 615-654-4441 sales@specialtyh2o.com 615-654-4449 fax TABLE OF CONTENTS Section 1 GENERAL 1.2 Warnings and Cautions... 1 1.2 Theory of Operation...

More information

USER S INFORMATION MANUAL

USER S INFORMATION MANUAL USER S INFORMATION MANUAL UPFLOW, DOWNFLOW, UPFLOW/HORIZONTAL & HORIZONTAL ONLY INDUCED DRAFT GAS FURNACES Recognize this symbol as an indication of Important Safety Information If the information in this

More information

Marschalk Model # 94000

Marschalk Model # 94000 Marschalk Model # 94000 12-volt DC Portable oil-less Air Compressor Operation Manual 27250006 REV 1 9/13/05 Table of Contents CHAPTER 1: SYSTEM DESCRIPTION... 5 FUNCTION AND THEORY... 5 SYSTEM COMPONENTS...

More information

400C & 450C DUAL PERFORMANCE VALUE PACKS

400C & 450C DUAL PERFORMANCE VALUE PACKS (Chrome) PART NO. 40013 (Silver) PART NO. 45012 (Chrome) PART NO. 45013 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual before

More information

120 PSI FAST-FILL AIR SOURCE KIT 25% Duty Compressor on 1.5 Gallon Air Tank

120 PSI FAST-FILL AIR SOURCE KIT 25% Duty Compressor on 1.5 Gallon Air Tank 120 PSI FAST-FILL AIR SOURCE KIT 25% Duty Compressor on 1.5 Gallon Air Tank PART NO. 20003 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of

More information

PumpAgents.com - Click here for Pricing/Ordering Nominal psi (bar) Cut-In Cut-Out

PumpAgents.com - Click here for Pricing/Ordering Nominal psi (bar) Cut-In Cut-Out PumpAgents.com - Click here for Pricing/Ordering Model 31670-Series Dual Max 7.5 GPM (28 LPM) AUTOMATIC TWO STAGE WATER SYSTEM WITH ACCUMULATOR TANK AND PUMPGARD STRAINER IDEAL FOR PLEASURE AND COMMERCIAL

More information

MODEL NUMBER: P PORTABLE COMPRESSOR

MODEL NUMBER: P PORTABLE COMPRESSOR MODEL NUMBER: 44043-440P PORTABLE COMPRESSOR IMPORTANT: It is essential that you and any other operator of the product read and understand the contents of this manual before installing and using this product.

More information

Nitrogen Supply System

Nitrogen Supply System ATMOSCOPE Nitrogen Supply System NS500 Users Guide Copyright 2001 EDSYN, INC. ATMOSCOPE Nitrogen Supply Systems TABLE OF CONTENTS Introduction............................. 3 General Information.......................

More information

170-CG Feed Unit SPONGE-JET USER MANUAL. Sponge-Jet, Inc. (USA) 14 Patterson Lane Newington, NH

170-CG Feed Unit SPONGE-JET USER MANUAL. Sponge-Jet, Inc. (USA) 14 Patterson Lane Newington, NH SPONGE-JET 170-CG Feed Unit USER MANUAL Sponge-Jet, Inc. (USA) 14 Patterson Lane +1-603-610-7950 Newington, NH 03801 www.spongejet.com AUGUST 2014, Sponge-Jet 170-CG User Manual - REV A / DOC: M-MKTG-002ENG

More information

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1 Dry 131h 1. DESCRIPTION The Viking Model G-1 Maintenance Air Compressor is an electric motor-driven, aircooled, single-stage, oil-less compressor. The unit is equipped with a check valve and provides a

More information

MODEL NUMBER: P-A AUTOMATIC PORTABLE COMPRESSOR

MODEL NUMBER: P-A AUTOMATIC PORTABLE COMPRESSOR MODEL NUMBER: 45043-450P-A AUTOMATIC PORTABLE COMPRESSOR IMPORTANT: It is essential that you and any other operator of the product read and understand the contents of this manual before installing and

More information

MODEL NUMBER: P PORTABLE COMPRESSOR

MODEL NUMBER: P PORTABLE COMPRESSOR MODEL NUMBER: 30033-300P PORTABLE COMPRESSOR IMPORTANT: It is essential that you and any other operator of the product read and understand the contents of this manual before installing and using this product.

More information

Pressure Regulators. Operating Instructions. Instrumentation

Pressure Regulators. Operating Instructions. Instrumentation Pressure Regulators Operating Instructions FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THIS PRODUCT CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE. This document and other information from the

More information

OxyCheq Expedition-X Oxygen Analyzer. Operator s Manual

OxyCheq Expedition-X Oxygen Analyzer. Operator s Manual OxyCheq Expedition-X Oxygen Analyzer Operator s Manual OxyCheq 3528 Russell Road Marianna, Florida 32446 USA Tel: 850.482.0385 Email: oxy@oxycheq.com Web: http://oxycheq.com CONTENTS 1.0 Introduction..

More information

SERVICE MANUAL MODEL BA050BMST BREATHING AIR PANEL

SERVICE MANUAL MODEL BA050BMST BREATHING AIR PANEL www.modsafe.com SERVICE MANUAL MODEL BA050BMST BREATHING AIR PANEL WARNING: Do not attempt to operate this equipment without first reading and understanding the service manual enclosed with this device.

More information

CONGRATULATIONS ON YOUR PURCHASE OF YOUR THUNDER COMPRESSOR For your personal safety please read, understand and follow the information provided in

CONGRATULATIONS ON YOUR PURCHASE OF YOUR THUNDER COMPRESSOR For your personal safety please read, understand and follow the information provided in CONGRATULATIONS ON YOUR PURCHASE OF YOUR THUNDER COMPRESSOR For your personal safety please read, understand and follow the information provided in this instruction manual. 1 CONTENTS 3. Safety Precautions

More information

450P- RV AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES

450P- RV AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES 450P- RV AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES PART NO. 45053 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual before installing

More information

NTF-515. Operation Manual

NTF-515. Operation Manual NTF-515 Operation Manual RTI Technologies, Inc. 10 Innovation Drive York, Pennsylvania 17402 USA Phone: 717-840-0678 Toll Free: 800-468-2321 Web-site: www.rtitech.com Manual P/N: 035-81474-00 (RevA) TABLE

More information

Nitrogen Tyre Inflator Owner s Manual

Nitrogen Tyre Inflator Owner s Manual Nitrogen Tyre Inflator Owner s Manual Model:PN-8890 Please read this manual carefully before attempting assembly or use. 1 Suit for: Motorcycle, Car, Light Truck, Bus Manual Model Nitrogen Tyre Inflation

More information

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS Annex 3, page 2 ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS The text of existing chapter 15 is replaced by the following: "1 Application This

More information

TESCOM 50-4X Series Safety, Installation & Start-Up Procedures

TESCOM 50-4X Series Safety, Installation & Start-Up Procedures Operations & Service Manual TESCOM 50-4X Series Safety, Installation & Start-Up Procedures Do not attempt to select, install, use or maintain this product until you have read and fully understood this

More information

Freedom8 ShoeBox Compressor Manual

Freedom8 ShoeBox Compressor Manual Freedom8 ShoeBox Compressor Manual Warning!! This product is not a toy! Use or misuse can cause severe injury or death! Use only with adult supervision. This unit is only to be used with tanks, hoses and

More information

4-7 kw/ hp. Dual Output Compressors (Air/Nitrogen) Driving Nitrogen Forward

4-7 kw/ hp. Dual Output Compressors (Air/Nitrogen) Driving Nitrogen Forward GN 4-7 kw/5.5-10 hp Dual Output Compressors (Air/Nitrogen) Driving Nitrogen Forward Total capability, total responsibility Right at the heart of your business, Atlas Copco delivers quality compressed air

More information

PAINTBALL

PAINTBALL 02012 www.nuvair.com PAINTBALL Table of Contents Ordering Ordering...3 High Pressure Compressors Coltri/Nuvair Portable... Coltri/Nuvair Compact Portable...5 Coltri/Nuvair Standard Electric...6 Coltri/Nuvair

More information

Operating Manual. Models AQT-02 & AQT-COO2 Manual No. MON004 (Rev 2 April 2000)

Operating Manual. Models AQT-02 & AQT-COO2 Manual No. MON004 (Rev 2 April 2000) Models AQT-02 & AQT-COO2 Manual No. MON004 (Rev 2 April 2000) Operating Manual AIR SYSTEMS INTERNATIONAL, INC. 829 Juniper Crescent, Chesapeake, Va., 23320 Telephone (757) 424-3967 Toll Free 1-800-866-8100

More information

R E D I C O N T R O L S

R E D I C O N T R O L S R E D I C O N T R O L S Operation & Maintenance Manual Portable Service Purger for Low Pressure Chillers Model: PSP-LP-1B For Refrigerants R-11, R-113, R-114 & R-123 & Other Similar Refrigerants File Literature

More information

Model PSI Compressor with 3-Gallon Air Tank 12VDC

Model PSI Compressor with 3-Gallon Air Tank 12VDC Model 6350 150 PSI Compressor with 3-Gallon Air Tank 12VDC IMPORTANT: It is essential that you and any other operator of this product read and understandd the contents of this manual before installing

More information

400H HARDMOUNT AIR COMPRESSOR KIT PART NO H HARDMOUNT AIR COMPRESSOR KIT PART NO

400H HARDMOUNT AIR COMPRESSOR KIT PART NO H HARDMOUNT AIR COMPRESSOR KIT PART NO 400H HARDMOUNT AIR COMPRESSOR KIT PART NO. 40042 450H HARDMOUNT AIR COMPRESSOR KIT PART NO. 45042 400H 450H IMPORTANT: It is essential that you and any other operator of this product read and understand

More information

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO 250C-IG COMPRESSOR KIT 12V PART NO. 25050 250C-IG COMPRESSOR KIT 24V PART NO. 25058 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual

More information

Part IV: Troubleshooting

Part IV: Troubleshooting Part IV: Troubleshooting Excessive Oil Carryover Pump-Up Time Test Excessive oil carryover can have adverse effects on the performance of pneumatic climate control systems. Although some oil entrainment

More information

Oxford Instruments Plasma Technology. PlasmaPro NGP80. Installation Data Sheet. Original Instructions.

Oxford Instruments Plasma Technology. PlasmaPro NGP80. Installation Data Sheet. Original Instructions. Oxford Instruments Plasma Technology www.oxford-instruments.com About this data sheet This data sheet provides basic information about the installation of a tool. Floor and wall loadings Table 1 lists

More information

ECS Protector Nitrogen Generator PGEN-30 (PGEN-30E)

ECS Protector Nitrogen Generator PGEN-30 (PGEN-30E) ECS Protector PGEN-30 (PGEN-30E) Specifications For use under U.S. Patents 8,720,591, 9,144,700 and 9,186,533 Dimensions (cabinet): 24.5 (W) x 52.5 (H) x 8.5 (D) (622mm(W) x 1,334mm(H) x 216mm(D)) Dimensions

More information

Model Air Caddy Orig TABLE OF CONTENTS

Model Air Caddy Orig TABLE OF CONTENTS 92-0919 Orig. 020201 Model 75-0114 Air Caddy TABLE OF CONTENTS CUSTOMER MESSAGE Inside Front Cover SAFETY PRECAUTIONS 3 GENERAL DESCRIPTION 6 SPECIFICATIONS 7 MAINTENANCE 9 INSTALLATION AND OPERATION 11

More information

RIX COMPRESSORS. MICROBOOST Owner s Manual CONFIGURATION A MB-115 MB-230. November 21, 2002 APPLICABILITY [ A]

RIX COMPRESSORS. MICROBOOST Owner s Manual CONFIGURATION A MB-115 MB-230. November 21, 2002 APPLICABILITY [ A] RIX COMPRESSORS MICROBOOST Owner s Manual CONFIGURATION A MB-115 MB-230 November 21, 2002 APPLICABILITY [ A] INTRODUCTION Safety This electromechanical equipment is designed to produce high pressure gas.

More information

SERVICE MANUAL MODEL BA200AA-S1 BREATHING AIR PANEL

SERVICE MANUAL MODEL BA200AA-S1 BREATHING AIR PANEL SERVICE MANUAL MODEL BA200AA-S1 BREATHING AIR PANEL WARNING: Do not attempt to operate this equipment without first reading and understanding the service manual enclosed with this device. 1/00 2 GENERAL

More information

CNG FILLING STATIONS

CNG FILLING STATIONS CNG FILLING STATIONS GAS INLET 3/4 F EXIT CNG TO CAR TANK 5 mt / 16 feet HOSE AND FILLING NOZZLE REMOTE ELECTRIC PANEL THREE-PHASE height 40 cm / 15.7 width 30 cm / 11.8 depth 20 cm / 7.8 EQUIPPED WITH

More information

PC 1010 Electric Air Compressor

PC 1010 Electric Air Compressor PC 1010 Electric Air Compressor Operating Instructions Warnings for the safe use of this compressor are included in this manual. TABLE OF CONTENTS INTRODUCTION... 3 SAFETY INSTRUCTIONS...3 INSPECTION...

More information

OPERATION AND MAINTENANCE INSTRUCTION MANUAL

OPERATION AND MAINTENANCE INSTRUCTION MANUAL OPERATION AND MAINTENANCE INSTRUCTION MANUAL AA-74 AIRPAC COMPRESSOR - 120 VOLT - TABLE OF CONTENTS: Introduction.........................1 Package Contents....................1 Operation...........................2

More information