California Building Code Effective January 2014 HOUSING ACCESSIBILITY BATHING FACILITIES Title 24, Part A

Size: px
Start display at page:

Download "California Building Code Effective January 2014 HOUSING ACCESSIBILITY BATHING FACILITIES Title 24, Part A"

Transcription

1 One common use bathing facilities such as bathtubs or showers are provided for residents or guests, at least one of each type of fixture in each facility and not less than 1% of all fixtures shall comply for accessibility. The following are summarized excerpts from some of the new building codes for these accessible bathroom fixtures. Please refer to the 2013 California Building Code books for more details and drawings. ACCESSIBLE BATHTUBS Bathtub Clear Floor Space A clear space of 30 x 60 shall be provided in front of a bathtub or shower compartment to allow parallel or side approach A clear space of 48 x 60 shall be provided in front of a bathtub or shower compartment to allow forward approach Clearance in front of bathtubs shall extend the length of the bathtub and shall be 48 wide minimum for forward approach and 30 wide minimum for parallel approach. The entrance opening into a roll-in shower compartment shall be a minimum of 42 wide with clear floor space of 48 deep An alternate roll-in shower opening shall be 36 wide minimum on the long side of a 36 x 60 shower compartment Bathtub Seats The foot end of the tub where the controls and water entry are located. The head end of the tub is opposite the foot end. A removable in-tub seat or permanent seat at the head end of the tub shall be provided The structural strength of seats and their attachments shall support a 250-pound load The top of bathtub seats shall be 17 minimum and 19 maximum The depth of a removable seat shall be 15 minimum and 16 maximum Page 1 of 7

2 The depth of a permanent seats at the head end of the bathtub shall be 15 deep minimum and shall extend from the back wall to or beyond the outer edge of the bathtub (fig 11A-9E) A permanent seat at the head end of the bathtub shall extend 12 minimum beyond the wall at the head end of the bathtub (fig 11A-9E) Bathtub Grab Bars When separate grab bars are required at a common mounting height, an L-shaped or U-shaped grab bar meeting dimensional requirements shall be permitted. Three grab bars shall be required for bathtubs with permanent seats. o Two 48 long horizontal grab bars shall be installed on the back wall 15 maximum from the head end wall and 12 maximum from the control end wall o One grab bar shall be located 33 minimum and 36 maximum above the finished floor measured to the top of the gripping service o The second grab bar shall be located 8 minimum and 10 maximum above the rim of the bathtub o A 24 long minimum third grab bar shall be installed on the control end wall at the front edge of the bathtub Three grab bars shall be required for bathtubs with removable seats. o Two 24 long horizontal grab bars shall be installed on the back wall 24 maximum from the head end wall and 12 maximum from the control end wall o One grab bar shall be located 33 minimum and 36 maximum above the finished floor measured to the top of the gripping service o The second grab bar shall be located 8 minimum and 10 maximum above the rim of the bathtub o A 24 long minimum third grab bar shall be installed on the control end wall at the front edge of the bathtub Page 2 of 7

3 Bathtub Controls Faucets and controls other than drain stoppers shall be located on an end wall between the bathtub rim and grab bar and between the open side of the bathtub and centerline of the width of the bathtub. Controls, faucets, and shower spray units shall be operable with one hand and shall not require tight grasping, pinching or twisting of the wrist. The force required to activate operable parts shall be 5 pounds maximum Bathtub/Shower Spray Units The hose shall be at least 59 long that can be used both as a fixed shower head and a hand-held shower The spray unit shall have an on/off control with a non-positive shut-off An adjustable height shower head on a vertical bar shall not obstruct the use of the grab bars Bathtub Enclosures Enclosures shall not obstruct controls, faucets, shower and spray units Enclosures shall not obstruct transfer from wheelchair onto bathtub seats or into bathtubs Enclosures on bathtubs shall not have tracks installed on the rib of the open face of the bathtub ACCESSIBLE ROLL-IN SHOWERS Standard Roll-in Shower Compartment Sizes 30 minimum depth and70 minimum width between wall surfaces with a full opening width on the long side 42 in width between wall surfaces and 48 minimum in depth with an entrance opening of 42 Page 3 of 7

4 Alternate Roll-in Shower Compartment Size 36 minimum in depth and 60 minimum in width between wall surfaces with a 36 wide minimum entrance at one end of the long side of the compartment Shower Floor Clearance A clear space of 30 x 60 shall be provided in front of a shower compartment to allow parallel or side approach. A clear space of 48 x 60 shall be provided in front of a shower compartment to allow forward approach Shower Thresholds in a Roll-In Shower Compartment ½ maximum in height with a beveled slope no greater than one vertical units in two units horizontal (50% slope) Exception changes in level not exceeding 1/4 shall be permitted to be vertical Shower Floor Slope Shower compartment floor surfaces shall be stable, firm and slip resistant The maximum slope of the floor shall be ¼ per food in any directions Grate openings in drains shall be ¼ maximum and located flush with the floor surface Shower Controls Controls, faucets, and shower spray units shall be operable with one hand and shall not require tight grasping, pinching or twisting of the wrist. The force required to activate operable parts shall be 5 pounds maximum Page 4 of 7

5 All controls shall be a of a single-lever design Operable parts of standard roll-in shower compartment controls and faucets shall be located above the grab bar on the back wall o Controls and faucets shall be mounted no higher than 48 above the shower floor with their centerline at 39 minimum and 41 maximum above the shower floor o Shower spray units including the handle shall be installed on the back wall adjacent to the seat wall, 29 minimum and 27 maximum from the seat wall and shall be no higher than 48 above the shower floor Operable parts of alternative roll-in shower compartment controls and faucets shall be located above the grab bar on the side wall adjacent to the seat wall, 19 minimum and 27 maximum from the seat wall o Controls and faucets shall be mounted no higher than 48 above the shower floor with their centerline at 39 minimum and 41 maximum above the shower floor o Shower spray units including the handle shall be installed on the side wall adjacent to the seat wall, 17 minimum and 19 maximum from the seat wall and shall be no higher than 48 above the shower floor or on the back wall opposite the seat 15 maximum, left or right of the centerline of the seat and shall be no higher than 48 above the shower floor Page 5 of 7

6 Hand-held Shower Spray Units The hose shall be at least 59 long that can be used both as a fixed shower head and a hand-held shower The spray unit shall have an on/off control with a non-positive shut-off An adjustable height shower head on a vertical bar shall not obstruct the use of the grab bars Page 6 of 7

7 Shower compartment seats A seat shall be a folding type, installed on the side wall adjacent to the controls The seat in a standard roll-in shower compartment shall extend from the back wall to a point within 3 of the compartment entry A seat in an alternate roll-in shower compartment shall be a folding type installed on the front wall opposite the back wall and shall extend from the adjacent side wall to a point within 3 of the compartment entry Seats shall be located within 27 of the shower controls The top of the seat shall be 17 minimum and 19 maximum above the bathroom finish floor When folded, the seat shall not extend more than 6 from the mounting wall Rectangular seats o The rear edge shall be 2-1/2 maximum from the seat wall o The front edge shall be 15 minimum and 16 maximum from the seat wall o The side edge of the seat shall be 1-1/2 maximum from the adjacent wall L-shaped seats o The rear edge shall be 2-1/2 maximum from the seat wall o The front edge shall be 15 minimum and 16 maximum from the seat wall o The rear edge shall be 1-1/2 maximum from the wall o The front edge shall be 14 minimum and 15 maximum from the wall o The end of the L shall be 22 minimum and 23 maximum from the main seat wall Page 7 of 7

ADA STANDARD OVERVIEW AND SPEAKMAN APPLICABLE PRODUCTS

ADA STANDARD OVERVIEW AND SPEAKMAN APPLICABLE PRODUCTS ADA STANDARD OVERVIEW AND SPEAKMAN APPLICABLE PRODUCTS ADA PRODUCT TRAINING PG. 1 Specs are for reference only. Please refer ADA.gov for the latest requirements. ADA What is the Americans with Disabilities

More information

ADA COMPLIANCE CHECKLIST (RESTAURANT) Meet Fail N/A. Parking Lot

ADA COMPLIANCE CHECKLIST (RESTAURANT) Meet Fail N/A. Parking Lot ADA COMPLIANCE CHECKLIST (RESTAURANT) Parking Lot Tow away warning at entrance to lot Accessible spaces - minimum 1, and at least 1 for each 25 spaces (e.g., 26 spaces requires 2 accessible spaces) Accessible

More information

Location: Cariboo, One Hundred Mile House, Cariboo Chilcotin Coast - Provincial : Park (Heritage Discovery Circle Route)

Location: Cariboo, One Hundred Mile House, Cariboo Chilcotin Coast - Provincial : Park (Heritage Discovery Circle Route) Mt Robson Visitors Centre Information Date of Audit: 2016-08-04 Park Name: Emerald Bay Sunset View Key Features: Camping,Picnic_Site,Beach,Trails,Playground,Fishing Location: Cariboo, One Hundred Mile

More information

REVIEW OF ACCESSIBILITY FEATURES

REVIEW OF ACCESSIBILITY FEATURES Developed by London's Municipal Accessibility Advisory Committee 1 REVIEW OF ACCESSIBILITY FEATURES Updated 2008-01-01 According to FADS 2007 Page 1 of 20 Developed by London's Municipal Accessibility

More information

City of Los Angeles Department of Building & Safety Disabled Access Section Supplemental Plan Review Checklist No. 8 RECREATION FACILITIES

City of Los Angeles Department of Building & Safety Disabled Access Section Supplemental Plan Review Checklist No. 8 RECREATION FACILITIES AMUSEMENT RIDES, BOAT SLIPS, BOWLING LANES, COURT SPORTS, FISHING PIERS Plan Check No. 1. Amusement rides required to comply with 11B-234, Amusement Rides shall provide accessible routes in accordance

More information

ACCESSIBILITY CHECKLIST

ACCESSIBILITY CHECKLIST ACCESSIBILITY CHECKLIST WASHINGTON STATE Northwest ADA Center University of Washington 6912 220 th Street SW Suite 105 Mountlake Terrace, WA 98043 Toll Free (800) 949-4232 TTD (425) 771-7426 www.nwadacenter.org

More information

Chapter 5. General Site and Building Elements

Chapter 5. General Site and Building Elements AMERICAN NATIONAL STANDARD Chapter 5. General Site and Building Elements Chapter 5. General Site and Building Elements 501 General 501.1 Scope. General site and building elements required to be accessible

More information

Example Applications of the Proposed Medical Diagnostic Equipment Accessibility Standards

Example Applications of the Proposed Medical Diagnostic Equipment Accessibility Standards Example Applications of the Proposed Medical Diagnostic Equipment Accessibility Standards January 23, 2012 U N I T E D S T A T E S A C C E S S B O A R D A FEDERAL AGENCY COMMITTED TO A C CESSIBLE DESIGN

More information

Accessible Swimming Pools and Spas

Accessible Swimming Pools and Spas Accessible Swimming Pools and Spas Introduction Accessible Swimming Pools and Spas Accessible Routes Types of Facilities and Required Means of Entry into the Water Pool Lifts Sloped Entries Transfer Walls

More information

ADA Library Accessibility Checklist

ADA Library Accessibility Checklist A. LIBRARIES Reading and Study Areas Do at least 5% (but not less than one) of fixed seating, tables, or study carrels have... Clear floor or ground spaces for wheelchairs? Clear space of 60" in diameter

More information

ADA Access Standards for Swimming Pools, Wading Pools, and Spas

ADA Access Standards for Swimming Pools, Wading Pools, and Spas ADA Access Standards for Swimming Pools, Wading Pools, and Spas The sports, places of amusement, and outdoor developed areas subcommittees each provided recommendations in this area. The recommendations

More information

CHAPTER 5: GENERAL SITE AND BUILDING ELEMENTS

CHAPTER 5: GENERAL SITE AND BUILDING ELEMENTS CHAPTER 5: GENERAL SITE AND BUILDING ELEMENTS 501 General 501.1 Scope. The provisions of Chapter 5 shall apply where required by Chapter 2 or where referenced by a requirement in this document. 502 Parking

More information

CURRENT ADA AND ICC COMPLIANCE DATA AN INTRODUCTION TO BOBRICK S ADA- COMPLIANT PRODUCTS, AS WELL AS BASIC MOUNTING HEIGHTS AND REACH RANGES

CURRENT ADA AND ICC COMPLIANCE DATA AN INTRODUCTION TO BOBRICK S ADA- COMPLIANT PRODUCTS, AS WELL AS BASIC MOUNTING HEIGHTS AND REACH RANGES CURRENT ADA AND ICC COMPLIANCE DATA AN INTRODUCTION TO BOBRICK S ADA- COMPLIANT PRODUCTS, AS WELL AS BASIC MOUNTING HEIGHTS AND REACH RANGES CURRENT ADA AND ICC COMPLIANCE DATA AN INTRODUCTION TO BOBRICK

More information

Global Lift ADA Compliance

Global Lift ADA Compliance February 9, 2012 Global Lift ADA Compliance All Global Lift Corp products comply with the ADA guidelines in 242.2 swimming pools and 242.4 spas 1009.2 pool lifts when installed following the specific Global

More information

SECTION SHOWER AND BATH ENCLOSURES. Display hidden notes to specifier by using Tools / Options / View / Hidden Text.

SECTION SHOWER AND BATH ENCLOSURES. Display hidden notes to specifier by using Tools / Options / View / Hidden Text. SECTION 10185 SHOWER AND BATH ENCLOSURES Display hidden notes to specifier by using Tools / Options / View / Hidden Text. PART 1 GENERAL 1.1 SECTION INCLUDES A. Bathtub wall enclosures. B. Shower wall

More information

Performance-Oriented Environmental Mobility Screen (POEMS)

Performance-Oriented Environmental Mobility Screen (POEMS) AMBULATION BEDROOM Gait is continuous, without hesitation. Gait is noncontinuous, with hesitation (1) (2). Gait is straight, without deviation from the Gait deviates from a straight path (1) (2) (5). path.

More information

ACCESSIBILITY CHECKLIST

ACCESSIBILITY CHECKLIST ACCESSIBILITY CHECKLIST WASHINGTON DEPARTMENT OF CORRECTIONS 2010 ADA STANDARDS FOR ACCESSIBLE DESIGN AND WASHINGTON STATE BUILDING CODE MARCH 2015 NORTHWEST ADA CENTER University of Washington 6912 220th

More information

Segment Number Quick Pathways Accessibility Tool. Name of Street: Segment Identification:

Segment Number Quick Pathways Accessibility Tool. Name of Street: Segment Identification: Quick Pathways Accessibility Tool Name of Street: Segment Identification: Date of survey: / / Name of surveyor(s): About this assessment: QPAT UIC Dept. of Disability and Human Development Page 1 of 15

More information

PUBLIC SPA CHECKLIST. Planning and Building Department City of Mississauga 300 City Centre Drive, 3th Floor Mississauga ON L5B 3C1

PUBLIC SPA CHECKLIST. Planning and Building Department City of Mississauga 300 City Centre Drive, 3th Floor Mississauga ON L5B 3C1 Planning and Building Department City of Mississauga 300 City Centre Drive, 3th Floor Mississauga ON L5B 3C1 PUBLIC SPA CHECKLIST This checklist is prepared for purposes of convenience only. For accurate

More information

Welcome to the AccessibilityOnline Webinar Series

Welcome to the AccessibilityOnline Webinar Series Welcome to the AccessibilityOnline Webinar Series A collaborative program between the ADA National Network and the US Access Board The Session is Scheduled to begin at 2:30pm Eastern Time We will be testing

More information

ROCKDALE COUNTY NEW SWIMMING POOL PLAN REVIEW

ROCKDALE COUNTY NEW SWIMMING POOL PLAN REVIEW ROCKDALE COUNTY NEW SWIMMING POOL PLAN REVIEW Pool Name: Address: Contractor: Phone: Number of Pools Applied for: The following is a list of facility requirements for opening a public pool. Read each requirement

More information

Aquatic Facility Evaluation City of Merriam, Kansas. Kyle A. McCawley, P.E. Larkin Aquatics 4/9/2014

Aquatic Facility Evaluation City of Merriam, Kansas. Kyle A. McCawley, P.E. Larkin Aquatics 4/9/2014 2014 Aquatic Facility Evaluation City of Merriam, Kansas Kyle A. McCawley, P.E. Larkin Aquatics 4/9/2014 Table of Contents Introduction... 2 Executive Summary... 2 Applicable Codes and Standards... 3 Facility

More information

United States Patent (19) Lotta

United States Patent (19) Lotta United States Patent (19) Lotta 54 SEATING UNIT FORA BATHTUB, SHOWER STALL OR THE LIKE 76 Inventor: Russell P. Lotta, 1632 Regina La., Rockford, Ill. 61102 21 Appl. No.: 790,401 22 Filed: Apr. 25, 1977

More information

ADA on Construction. Guidance for Section C Plan Preparers

ADA on Construction. Guidance for Section C Plan Preparers ADA on Construction Guidance for Section C Plan Preparers Some impacts cannot be avoided and those impacts apply to residents, businesses, motorists, and pedestrians alike. However, good planning can minimize

More information

Accommodating Pedestrians in the Work Zone

Accommodating Pedestrians in the Work Zone Accommodating Pedestrians in the Work Zone Guidance for Section C Plan Preparers Some impacts cannot be avoided and those impacts apply to residents, businesses, motorists, and pedestrians alike. However,

More information

Swimming Pool Fence Guide Kodiak Iron

Swimming Pool Fence Guide Kodiak Iron Swimming Pool Fence Guide Kodiak Iron Exceptional Fencing Extraodinary Customer Service BOCA National Building Code (Building Officials and Code Administrators International Inc.) This nonprofit agency

More information

Choosing a Walk-in or Accessible Bathtub

Choosing a Walk-in or Accessible Bathtub Choosing a Walk-in or Accessible Bathtub by Shari McDowell Buying an Accessible Bathtub is a major decision. It involves a substantial amount of money, and the inconvenience of a bathroom renovation. It

More information

Unit # ± 5,514 SF Width ± 85' Depth ± 68' Plans produced by: ID Plans 10/12/2016 (813)

Unit # ± 5,514 SF Width ± 85' Depth ± 68' Plans produced by: ID Plans 10/12/2016 (813) ±50' Lease Line ±20' ±15' Lease Outline Drawing ±65' Lease Line ±68' Lease Line Sunnymead Plaza 24949 Sunnymead Blvd., Moreno Valley, CA 92553 Unit # 24949 ± 5,514 SF Width ± 85' Depth ± 68' Plans produced

More information

SWIMMING POOLS/SPAS/HOT TUBS PLAN REVIEW GUIDE SHEET

SWIMMING POOLS/SPAS/HOT TUBS PLAN REVIEW GUIDE SHEET SWIMMING POOLS/SPAS/HOT TUBS PLAN REVIEW GUIDE SHEET Sect. 106-748, City Code of Ordinances: Regulations are applicable to both above and inground swimming pools, spas and hot tubs. POOL PLACEMENT Measurement

More information

Portland Peninsula Sidewalk and Ramp Inventory

Portland Peninsula Sidewalk and Ramp Inventory Portland Peninsula Sidewalk and Ramp Inventory Conducted June and July of 2008 By Anne Krikorian and Ryan Carmichael Performed under the authority of: Greater Portland Council of Governments And with the

More information

ada compliance swimming pool Compliance guide

ada compliance swimming pool Compliance guide swimming pool Compliance guide accessibility equipment pool lifts S.R. Smith is your source for 3rd party tested and ADA compliant pool lifts that work for virtually any pool design or application. From

More information

GWINNETT COUNTY SWIMMING POOL PLAN REVIEW CHECKLIST

GWINNETT COUNTY SWIMMING POOL PLAN REVIEW CHECKLIST GWINNETT COUNTY SWIMMING POOL PLAN REVIEW CHECKLIST Pool Name: Address: Contractor: Phone: Number of Pools Applied for: GENERAL INFORMATION Plan review paid Pool Piping plan stamped by Design Professional.

More information

FINDLAY TOWNSHIP BUILDING INSPECTION DEPT

FINDLAY TOWNSHIP BUILDING INSPECTION DEPT Page 1 of 7 FINDLAY TOWNSHIP BUILDING INSPECTION DEPT. RESIDENTIAL SWIMMING POOLS Permit application submittal requirements (As per the 2009 International Residential Code) NOTE: A building permit is required

More information

SNT Installation of a SNT Walk In Bath Tub follows the basic steps below. SNT: $2,248.00

SNT Installation of a SNT Walk In Bath Tub follows the basic steps below. SNT: $2,248.00 PRICE: $5,862.00 SNT WHIRLPOOL ADA WALK IN TUB Want a walk-in bathtub that has all the bells and whistles? Need a safe solution for bathing that's also luxurious and relaxing? The Sanctuary Whirlpool Duo

More information

RESIDENTIAL SWIMMING POOLS AND SPAS A GUIDE FOR HOMEOWNERS

RESIDENTIAL SWIMMING POOLS AND SPAS A GUIDE FOR HOMEOWNERS RESIDENTIAL SWIMMING POOLS AND SPAS A GUIDE FOR HOMEOWNERS City of Redding 777 Cypress Avenue Redding CA 96001 Telephone: (530) 225-4013 FAX: (530) 225-4360 A Swimming Pool is any body of water 18 inches

More information

RESOLUTION A.1045(27) RECOMMENDATION ON PILOT TRANSFER ARRANGEMENTS

RESOLUTION A.1045(27) RECOMMENDATION ON PILOT TRANSFER ARRANGEMENTS RESOLUTION A.1045(27) RECOMMENDATION ON PILOT TRANSFER ARRANGEMENTS 1 GENERAL Ship designers are encouraged to consider all aspects of pilot transfer arrangements at an early stage in design. Equipment

More information

Swimming Pool Plans and Specification Report

Swimming Pool Plans and Specification Report Swimming Pool Plans and Specification Report For TCHD Use Only Date Received by Employee Number: *Plans Received Yes No *$120.00 Plan Review Fee Paid Yes No *Facility Name: Phone: *Address: *Owner: *Phone:

More information

Standards vs. Guidelines. Public Right-of Way Accessibility Guidelines (PROWAG)

Standards vs. Guidelines. Public Right-of Way Accessibility Guidelines (PROWAG) www.access-board.gov Public Right-of Way Accessibility Guidelines (PROWAG) Juliet Shoultz, P.E Transportation Systems Engineer US Access Board Standards vs. Guidelines Guidelines are developed by the Access

More information

Swimming Pools, Hot Tubs and Spas

Swimming Pools, Hot Tubs and Spas OLATHE FIRE DEPARTMENT BUILDING CODES 1225 S. Hamilton Circle Olathe, KS 66061 / Main: (913) 971-7900 / Fax: (913) 971-9812 Swimming Pools, Hot Tubs and Spas Definitions: Swimming Pool- Any structure intended

More information

SWIMMING POOL CERTIFICATE GUIDE

SWIMMING POOL CERTIFICATE GUIDE SWIMMING POOL CERTIFICATE GUIDE FEBRUARY BUILDING DRAWING - KEY PLAN POOL DRAWINGS - / Longitudinal Section / Floor Plan / Cross Section / MEASUREMENT CRITERIA.- The measurements shall be done by a ceritfied

More information

Invacare Top End Recreation Handcycles Tutorial

Invacare Top End Recreation Handcycles Tutorial Invacare Top End Recreation Handcycles Tutorial Invacare Top End XLT Handcycle Invacare Top End Excelerator Stock Handcycle Invacare Top End Excelerator Custom Handcycle Invacare Top End Lil' Excelerator

More information

BP 344 IMPLEMENTING RULES AND REGULATIONS (IRR) AMENDMENTS MINIMUM REQUIREMENTS FOR ACCESSIBILITY

BP 344 IMPLEMENTING RULES AND REGULATIONS (IRR) AMENDMENTS MINIMUM REQUIREMENTS FOR ACCESSIBILITY BP 344 IMPLEMENTING RULES AND REGULATIONS (IRR) AMENDMENTS MINIMUM REQUIREMENTS FOR ACCESSIBILITY A. GENERAL PROVISIONS 1. Accessible Ramps 1.1 Changes in level shall require a ramp except when served

More information

Chapter 10 SWIMMING POOLS

Chapter 10 SWIMMING POOLS 4-10-1: COMPLIANCE REQUIRED: Chapter 10 SWIMMING POOLS It shall be unlawful to construct, maintain, install or enlarge any swimming pool in the City except in compliance with the provisions of this Chapter.

More information

Revisions to the Regulations for Agility Trials

Revisions to the Regulations for Agility Trials Revisions to the Regulations for Agility Trials Effective January 2, 2018 Equipment changes may be done prior to January 2, 2018, but must be completed by January 2, 2018 This insert is issued as a supplement

More information

Residential Swimming pools

Residential Swimming pools City of Republic Community Development Department Residential Swimming pools REVISION DATE: JANUARY 2017 Swimming Pool Safety Definitions: Barrier Requirements: A) Application All swimming pools over 24

More information

Building Code Guidelines For Home Pools

Building Code Guidelines For Home Pools Building Code Guidelines For Home Pools KEEP YOUR POOL SAFE Department of Inspections 17140 Monument Circle Suite 100 Isle of Wight, Virginia 23397 757-365-6213/6215 CODE REQUIREMENTS FOR SWIMMING POOLS

More information

Swimming Pool Requirements

Swimming Pool Requirements Swimming Pool Requirements 8040 S. 6th Street Oak Creek, WI 53154 (414) 766-7000 www.oakcreekwi.org Revised: August 8. 2017 PERMITS A permit from the Inspection Department is required prior to putting

More information

REQUIREMENTS FOR NEW AND EXISTING DOMESTIC SWIMMING POOLS

REQUIREMENTS FOR NEW AND EXISTING DOMESTIC SWIMMING POOLS Lismore City Council REQUIREMENTS FOR NEW AND EXISTING DOMESTIC SWIMMING POOLS (Swimming Pools Act 1992) Introduction The purpose of this pamphlet is to inform the community about the requirements of the

More information

Discus Technical Model

Discus Technical Model Discus Technical Model Progression related to Multi-Events Development (aged 8/9-12 years) can be referenced to Athletics 365 stages Red, Yellow & Green Whole Sequence Preparation Momentum Building Delivery

More information

Small. Regulation Reference: (see page 23 for link to the regulation)

Small. Regulation Reference: (see page 23 for link to the regulation) The Requirements of this Section apply to: Government of Ontario, Legislative Assembly, and Designated Public Sector Organizations Private / Not-for-Profit Sector Organizations Large Small Regulation Reference:

More information

Palmer township, Pennsylvania. Pool & Fence Details Based on the 2009 International Residential Code (Designed and Printed January 2012)

Palmer township, Pennsylvania. Pool & Fence Details Based on the 2009 International Residential Code (Designed and Printed January 2012) Palmer township, Pennsylvania Pool & Fence Details Based on the 2009 International Residential Code (Designed and Printed January 2012) CONTENTS General Information... 2 Prohibited Barrier Locations..

More information

Field guide for Accessible Public Rights-of-Way Edition

Field guide for Accessible Public Rights-of-Way Edition Field guide for Accessible Public Rights-of-Way 2017 Edition CONTENTS PEDESTRIAN FACILITIES IN THE PUBLIC RIGHT-OF-WAY Pedestrian access routes 3 Components 3 Continuous width 3 Median and pedestrian refuge

More information

Operator Interface Enclosures

Operator Interface Enclosures ` www.hammfg.com s - NEMA 12, 13 Tara Plus 600 (135.2 lbs) 500 (112.4 lbs) Weight in Newtons 400 (90.1 lbs) 300 (67.4 lbs) 200 (45.1 lbs) 100 (22.5 lbs) 0.50 (1.6 ft) 1.00 (3.28 ft) Extension in Meters

More information

Florida Building Code 6 th Edition (2017) Residential. Broward County Edition Loose-leaf Supplement

Florida Building Code 6 th Edition (2017) Residential. Broward County Edition Loose-leaf Supplement Board of Rules and Appeals FBC 6 th Edition (2017)- Residential - Supplement No. 1 January 1, 2018 Florida Building Code 6 th Edition (2017) Residential File removed pages for reference. Broward County

More information

HIP PRECAUTIONS INFORMATION

HIP PRECAUTIONS INFORMATION HIP PRECAUTIONS INFORMATION PAGE Hip Precautions Sitting Safely Following Precautions 1-2 Hip Safety: Sleeping Positions Safe Sleeping 3-4 Hip Safety: Getting Into and Out of Bed 5-6 Hip Safety Sitting

More information

Palmer township, Pennsylvania. Pool Fence Details Based on the 2009 International Residential Code (Designed and Printed January 2012)

Palmer township, Pennsylvania. Pool Fence Details Based on the 2009 International Residential Code (Designed and Printed January 2012) Palmer township, Pennsylvania Pool Fence Details Based on the 2009 International Residential Code (Designed and Printed January 2012) CONTENTS General Information... 2 Above-Ground Pool. 4 Barrier Requirements....

More information

SPECIAL LAUNCHING METHODS

SPECIAL LAUNCHING METHODS CHAPTER 18 SPECIAL LAUNCHING METHODS Special launching methods are needed when a restricted site prevents normal roller layout and launching by the standard skeleton launchingnose method. Space on either

More information

Chung Yong Hapkido Kup Grade Syllabus

Chung Yong Hapkido Kup Grade Syllabus 2009 Chung Yong Hapkido Kup Grade Syllabus This document outlines the basic requirements for students to progress from white belt to red belt. An exam to prove a student s proficiency should be undertaken

More information

SWIMMING POOL, SPA, & HOT TUB GUIDELINES

SWIMMING POOL, SPA, & HOT TUB GUIDELINES SWIMMING POOL, SPA, & HOT TUB GUIDELINES A. Adopted construction codes and installation requirements 1. 2015 edition of the International Residential Code and Appendix Q, 2. 2014 edition of the National

More information

ADA Design Overview. Section 2. ADA Design Overview. Pedestrian Access Routes. Pedestrian Access Routes. Overview

ADA Design Overview. Section 2. ADA Design Overview. Pedestrian Access Routes. Pedestrian Access Routes. Overview ADA Design Overview Section 2 ADA Design Overview Overview Accessible Pedestrian Signals Alternate Fall, 2017 Ann Johnson, PE Services Brady Rutman, SRF Consulting Group 2 Pedestrian Access Route (PAR)

More information

RULES PUBLICATION NO. 44//P PILOT TRANSFER ARRANGEMENTS July

RULES PUBLICATION NO. 44//P PILOT TRANSFER ARRANGEMENTS July RULES PUBLICATION NO. 44//P PILOT TRANSFER ARRANGEMENTS 2016 July Publications P (Additional Rule Requirements) issued by Polski Rejestr Statków complete or extend the Rules and are mandatory where applicable.

More information

Field guide for Accessible Public Rights-of-Way Edition

Field guide for Accessible Public Rights-of-Way Edition Field guide for Accessible Public Rights-of-Way 2015 Edition BRIEFING MEMO SUBJECT: Department of Justice/Department of Transportation Joint Technical Assistance on Title II of the Americans with Disabilities

More information

OLD GI PART 3, FIXED LADDERS COMPARISON TO NEW RULES

OLD GI PART 3, FIXED LADDERS COMPARISON TO NEW RULES This table compares the rescinded rules for fixed ladders from old GI Part 3 with the new rules for fixed ladders in GI Part 2, Walking-Working Surfaces. The first column contains the rescinded rule (struckthrough).

More information

POOL BARRIER AMENDMENTS & GUIDELINES: APPENDIX G SWIMMING POOLS, SPAS AND HOT TUBS

POOL BARRIER AMENDMENTS & GUIDELINES: APPENDIX G SWIMMING POOLS, SPAS AND HOT TUBS SECTION AG101 - GENERAL POOL BARRIER AMENDMENTS & GUIDELINES: APPENDIX G SWIMMING POOLS, SPAS AND HOT TUBS AG101.1 General. The requirements of this appendix shall apply to the design and construction

More information

Swimming Pool Requirements

Swimming Pool Requirements Swimming Pool Requirements 1. Definitions: Approved Safety Pool Cover. Means a manually or power-operated safety pool cover that meets all of the performance standards of the American Society for Testing

More information

Thrower s Maintenance Program

Thrower s Maintenance Program Thrower s Maintenance Program Elbow at 90 and fixed at side. Pull out with arm keeping elbow at side Elbow at 90 and fixed at side. Pull arm into body keeping elbow at side. Shoulder at 90 and elbow at

More information

Pool Submittal & Inspection Packet

Pool Submittal & Inspection Packet Pool Submittal & Inspection Packet Submit all applications online at www.mckinneytexas.org/css Residential Pool Plans Submittal Requirements 1. Pool permits are applied for online at www.mckinneytexas.org/css.

More information

Shoulder Exercises for Combined Labrum Repair Rehabilitation Protocol

Shoulder Exercises for Combined Labrum Repair Rehabilitation Protocol Shoulder Exercises for Combined Labrum Repair Rehabilitation Protocol The exercises illustrated and described in this document should be performed only after instruction by your physical therapist or Dr.

More information

Circular Turning Space. 8 Significant Changes to the ICC A

Circular Turning Space. 8 Significant Changes to the ICC A 8 Significant Changes to the ICC A117.1 2017 304.3.1 Circular Turning Space CHANGE TYPE: Modification CHANGE SUMMARY: Within new buildings, the size of a circular turning space has been increased from

More information

RESIDENTIAL SWIMMING POOL REQUIREMENTS

RESIDENTIAL SWIMMING POOL REQUIREMENTS CITY OF GRANDVIEW / BUILDING SERVICES 1200 MAIN STREET, GRANDVIEW, MO 64030 PHONE: (816) 316-4817 FAX: (816) 316-4809 WWW.GRANDVIEW.ORG RESIDENTIAL SWIMMING POOL REQUIREMENTS Community Development Department

More information

Design Overview. Section 4 Standard Plans for Design. Pedestrian Access Routes. Pedestrian Access Routes. Overview. Cross Slope

Design Overview. Section 4 Standard Plans for Design. Pedestrian Access Routes. Pedestrian Access Routes. Overview. Cross Slope Design Overview Section 4 Standard Plans for Design Fall, 2017 Ann Johnson, PE Services Brady Rutman, SRF Consulting Group Overview Design Basics Recommendations: The Zone System Driveway Crossings Pedestrian

More information

Saskatchewan Health S A WHIRLPOOL DESIGN/OPERATIONAL T C H E W STANDARDS. Updated 02/00

Saskatchewan Health S A WHIRLPOOL DESIGN/OPERATIONAL T C H E W STANDARDS. Updated 02/00 Saskatchewan Health S A S K A T C H E W A N WHIRLPOOL DESIGN/OPERATIONAL STANDARDS Updated 02/00 FOREWORD These standards should be read in conjunction with The Swimming Pool Regulations, 1999. Saskatchewan

More information

CITY OF MISSION VIEJO BUILDING SERVICES DIVISON 200 CIVIC CENTER MISSION VIEJO, CA (949)

CITY OF MISSION VIEJO BUILDING SERVICES DIVISON 200 CIVIC CENTER MISSION VIEJO, CA (949) CITY OF MISSION VIEJO BUILDING SERVICES DIVISON 200 CIVIC CENTER MISSION VIEJO, CA 92691 (949) 470-3054 RESIDENTIAL BARRIERS FOR SWIMMING POOLS, SPAS AND HOT TUBS BARRIERS FOR SWIMMING POOLS, SPAS AND

More information

California Conference of Directors of Environmental Health Recreational Health Technical Advisory Committee September 17, 2003

California Conference of Directors of Environmental Health Recreational Health Technical Advisory Committee September 17, 2003 California Conference of Directors of Environmental Health Recreational Health Technical Advisory Committee September 17, 2003 RECREATIONAL WATER PARKS GUIDELINES Definitions. ACTIVITY POOL means a pool

More information

Chapter BICYCLE PARKING REQUIREMENTS

Chapter BICYCLE PARKING REQUIREMENTS The following are proposed text changes to Chapter 17.117. Additions to the chapter are underlined; deletions are in strikeout. Chapter 17.117 BICYCLE PARKING REQUIREMENTS Sections: Article I. - General

More information

Building Code Guidelines For Home Pools

Building Code Guidelines For Home Pools Building Code Guidelines For Home Pools KEEP YOUR POOL SAFE Department of Development and Permits 306 Cedar Road, City Hall 2 nd Floor Chesapeake, VA 23322 Phone: (757) 382-6018 E-mail: develop-permits@cityofchesapeake.net

More information

GENERAL. 1. Description

GENERAL. 1. Description GENERAL 1. Description This standard identifies minimum requirements that shall be met for all Bus Stops in the design and construction of elements for Arlington County Horizontal Design Standards. This

More information

How-To-Buy Guide for Bathtubs & Whirlpools

How-To-Buy Guide for Bathtubs & Whirlpools Bathrooms, they re what life s made of How-To-Buy Guide for Bathtubs & Whirlpools By Gray Uhl Brand Education Director American Standard BATHROOM FAUCETS HOW-TO-BUY GUIDE FOR BATHtubs and whirlpools 1

More information

NO wiring shall be above the pool within 10, measured horizontally, or under a pool within 5, measured horizontally.

NO wiring shall be above the pool within 10, measured horizontally, or under a pool within 5, measured horizontally. CITY OF PARK RIDGE 505 BUTLER PLACE PARK RIDGE, IL 60068 TEL: 847/ 318-5291 FAX: 847/ 318-6411 TDD:847/ 318-5252 URL:http://www.parkridge.us DEPARTMENT OF COMMUNITY PRESERVATION AND DEVELOPMENT BUILDING

More information

ACCESSIBILITY STANDARDS for the BUILT ENVIRONMENT

ACCESSIBILITY STANDARDS for the BUILT ENVIRONMENT ACCESSIBILITY STANDARDS for the BUILT ENVIRONMENT City of Kitchener 200 King Street West, Kitchener, ON N2G 4G7 P. 519.741.2200 TTY. 1.866.969.2624 The City of Kitchener is committed to providing accessible

More information

dpd Seattle Permits Tip Getting a Grip on Handrails PURPOSE OF HANDRAILS

dpd Seattle Permits Tip  Getting a Grip on Handrails PURPOSE OF HANDRAILS dpd Department of Planning and Development Tip 319 Seattle Permits part of a multi-departmental City of Seattle series on getting a permit Getting a Grip on Handrails Updated March 2, 2007 PURPOSE OF HANDRAILS

More information

GUARDIAN EQUIPMENT Emergency Eye Wash and Shower Equipment. ANSI Z358.1 Compliance Checklist

GUARDIAN EQUIPMENT Emergency Eye Wash and Shower Equipment. ANSI Z358.1 Compliance Checklist GUARDIAN EQUIPMENT Emergency Eye Wash and Shower Equipment ANSI Z358.1 Compliance Checklist Compliance Checklist Introduction The selection of emergency eye wash and shower equipment is often a complicated

More information

Inflatable Dock Slide Owner s Manual

Inflatable Dock Slide Owner s Manual Inflatable Dock Slide Owner s Manual Introduction Water sports can be safe and fun for all levels of enthusiasts. The Owner s Manual is presented to enhance your enjoyment of the sport. It is intended

More information

MUGAS Please contact us directly for pricing.

MUGAS Please contact us directly for pricing. MUGAS Fencing Options Explained PREMIERSHIP FENCING MUGAs A strong, high quality, durable rebound fencing option perfect for high intensity rebound requirements or areas where high the highest vandal resistance

More information

ARCHITECTURAL AND TRANSPORTATION BARRIERS COMPLIANCE BOARD

ARCHITECTURAL AND TRANSPORTATION BARRIERS COMPLIANCE BOARD Page 1 of 107 ARCHITECTURAL AND TRANSPORTATION BARRIERS COMPLIANCE BOARD 36 CFR Part 1191 [Docket No. 98-5] RIN 3014-AA16 Published in the Federal Register on September 3, 2002. Summary Background General

More information

At Home. SCI Arm Workout

At Home. SCI Arm Workout At Home SCI Arm Workout Just because your therapy may be over doesn t mean that your workouts should be. Use this packet to get an effective workout at home 1 of 2 ways: -theraband or -free weights Also

More information

NEW SWIMMING POOL PLAN APPROVAL REQUIREMENTS

NEW SWIMMING POOL PLAN APPROVAL REQUIREMENTS University of California Santa Barbara Environmental Health & Safety- Environmental Health Program 565 Mesa Rd. Santa Barbara, CA 93106 (805) 893-2471 NEW SWIMMING POOL PLAN APPROVAL REQUIREMENTS This

More information

Requirements for Swimming Pools

Requirements for Swimming Pools Requirements for Swimming Pools A B-100 permit from Northeast District Dept. of Health, a Zoning Permit and a Building Permit are required. An Engineered Stamped plan must be submitted with any permit

More information

10-MINUTE "EXPERT" MTI Edition

10-MINUTE EXPERT MTI Edition 10-MINUTE "EXPERT" MTI Edition A brief training brochure for busy plumbing industry professionals (Revised 02/17) Western Sales Company sales@western-sales.com 408-353-9000 western-sales.com Overview Brief

More information

How Do I Install My Garden Master Bucket Garden?

How Do I Install My Garden Master Bucket Garden? How Do I Install My Garden Master Bucket Garden? 1. On the arrival of your Bucket Garden open the bucket and remove the 4 screws from the outside of the bucket rim and pull the 2 buckets apart. Check the

More information

FEE SCHEDULE POOL PERMIT FEES. Refundable Security (Cash of L.C.) 1 Hot Tub, Spa, etc. $ nil 2 Above Ground Pool $ nil

FEE SCHEDULE POOL PERMIT FEES. Refundable Security (Cash of L.C.) 1 Hot Tub, Spa, etc. $ nil 2 Above Ground Pool $ nil FEE SCHEDULE POOL PERMIT FEES Type of Pool Total Fee Refundable Security (Cash of L.C.) 1 Hot Tub, Spa, etc. $100.00 nil 2 Above Ground Pool $200.00 nil 3 Inground Pools (assumed $350.00 $1500.00 subdivision)

More information

SWIMMING POOL REQUIREMENTS

SWIMMING POOL REQUIREMENTS PERMITS A permit from the Inspection Department is required prior to putting up a permanent pool. A permit is required for permanent pools, such as the following: SWIMMING POOL REQUIREMENTS The pool is

More information

Installation/Care/Use Manual

Installation/Care/Use Manual Installation/Care/Use Manual EMASM Surface Mount Bottle Filling Station IMPORTANT THIS IS AN INDOOR APPLICATION ONLY! ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSONNEL. TOOLS/ITEMS REQUIRED

More information

AKIT1901LM (Metal levers) AKIT1901XM (Cross Handles)

AKIT1901LM (Metal levers) AKIT1901XM (Cross Handles) PALLADIAN EXPOSED TUB SET WITH HANDSHOWER AKIT1901LM (Metal levers) AKIT1901XM (Cross Handles) COLORS/FINISHES WARRANTY FEATURES Palladian metal levers or cross handles Floor mounted exposed two handle

More information

BATHS SHOWERS WALK-IN TUBS

BATHS SHOWERS WALK-IN TUBS BATHS SHOWERS WALK-IN TUBS HOW WE COMPARE WEST SHORE HOME NATIONAL BRAND MILDEW PREVENTION TECHNICIANS INSTALLATION METHOD INTERACTIVE DESIGN TOOL In-House Employee Full Replacement YES Subcontractor Liner

More information

Swimming Pool Installation

Swimming Pool Installation Swimming Pool Installation The following information is provided to assist in the planning and installation of swimming pools and hot tubs within the City of Vandalia, OH. Zoning, Fence and Electric Permits

More information

ADA Transition Plan. Washington County. Inventory Manual. June, 2014 DRAFT

ADA Transition Plan. Washington County. Inventory Manual. June, 2014 DRAFT ADA Transition Plan Washington County Inventory Manual June, 2014 DRAFT ADA Transition Plan Washington County Inventory Manual Client Washington County Consultant Team SRF Consulting Group, Inc. Consulting

More information

Dragon Boats NSW Inc.

Dragon Boats NSW Inc. Dragon Boats NSW Inc. (Incorporated under the Associations Incorporation Act, 2009) (Registered Number: Y2086230) (ABN 31 936 733 882) Boat Handling and Storage Policy Thanks to Mavericks and FFB Dragon

More information

Premiership MUGAs. 1m Sides. 2m Sides MC16201 MC MC MC12101/MC16201/MC18101 Multi Courts MC12102 MC16202 MC185102

Premiership MUGAs. 1m Sides. 2m Sides MC16201 MC MC MC12101/MC16201/MC18101 Multi Courts MC12102 MC16202 MC185102 614448 01296 Premiership MUGAs MUGAs or Multi Use Games Areas, are a perfect addition to any community, School, University, College or Leisure space. To encourage fitness and keeping fit these contained

More information

Ordinance amendments are included below. New language is underlined in red. Deleted language is lined-through.

Ordinance amendments are included below. New language is underlined in red. Deleted language is lined-through. City staff, with the assistance of National Inspection Corporation (NIC), has reviewed current requirements for swimming pools from the 2011 National Electric Code (NEC), advisory regulations from the

More information