ADA STANDARD OVERVIEW AND SPEAKMAN APPLICABLE PRODUCTS

Size: px
Start display at page:

Download "ADA STANDARD OVERVIEW AND SPEAKMAN APPLICABLE PRODUCTS"

Transcription

1 ADA STANDARD OVERVIEW AND SPEAKMAN APPLICABLE PRODUCTS ADA PRODUCT TRAINING PG. 1 Specs are for reference only. Please refer ADA.gov for the latest requirements.

2 ADA What is the Americans with Disabilities Act (ADA)? THE ADA STANDARD WAS DEVELOPED TO ENSURE that the built environment was accessible to people with disabilities. The ADA Standards Water Closet Diagram establish the necessary design requirements for the construction and alteration of facilities subject to the law. These enforceable standards apply to places of public accommodation, commercial facilities, and state and local government facilities. Speakman Company takes care to follow these guidelines and designs our products to comply with them. The ADA Standards apply nationwide, in addition to any applicable state or local codes, where facilities are newly built or altered...the Access Board s 2004 ADA Accessibility Guidelines, upon which the current ADA Standards are based, have been harmonized to a significant extent with industry standards and model building codes... Considering this, our products comply with both the ADAAG TOWEL RACK Robe Hook 42 min. and ICC/ANSI A117.1 requirements. The United States Access Board is responsible for the development and maintenance of the guidelines. These guidelines, are known as ADA Accessibility Guidelines or ADAAG for short. Chapter 6 of the Standard is for TOILET Plumbing Elements & Facilities. Source: BATHROOM sites/about-the-ada-standards FIG ADA PRODUCT TRAINING PG. 2 Specs are for reference only. Please refer to ADA.gov for the latest requirements.

3 ADA WATER CLOSET REQUIREMENTS 603 Toilet & Bathing Rooms COAT HOOKS AND SHELVES: Coat hooks shall be located within one of the reach ranges specified in Section 308. Shelves shall be 40 minimum and 48 maximum above the floor. General Note: Throughout Chapter 6 is the exception that Grab bars are not required to be installed in private washrooms for a single occupant, washrooms that can only REAR WALL S: 36 In. minimum length installed horizontally. There are exceptions to this length where wall space does not permit for a 36 In. length bar COAT HOOKS & SHELVES: Coat Hooks: Mounted maximum 48 In. above the floor Shelves: Mounted minimum 40 In. & maximum 48 In. above the floor be accesses via a private office or that are not for common or public use. 604 Water Closets & Toilet Compartments SPEAKMAN ACCESSORY SOLUTIONS: Robe Hooks Towel Racks Note: this outlines the specification for an adult washroom, section is specific to Water Closets & Toilet Compartments for Children s Use. SA-1008 SA-1008-BN SA-2003 SA-2003-BN S: Grab Bars for water closets shall comply with Section 609 and shall be provided in accordance with Sections & Grab bars shall be provided on the rear wall & on the side wall closest to the water closet. SA-1306 SA-1406 SA-1607-PC SA-2203 SA-2203-BN SA-2303 SA-2403 SA-2403-BN FIXED SIDE WALL S: 42 In. minimum length installed horizontally. 18 In. minimum length bar installed vertically FIXED SIDE WALL S: 42 In. minimum length installed horizontally. 18 In. minimum length bar installed vertically. SA-2006 SA-2006-BN SA-2306 SA-2406 SA-2406-BN SA-2408 SA-2408-BN ADA Grab Bars SA SA BN SA SA BN SA SA BN SA SA BN SA SA BN SA SA BN ADA PRODUCT TRAINING PG. 3 Specs are for reference only. Please refer ADA.gov for the latest requirements.

4 ADA COMPLIANT FAUCETS 606 Lavatories & Sinks SB-1821-E SB-1821-E-BN SC-3004-FC-LD S-8728-CA-E FAUCETS: S-8828-CA-E Faucets shall comply with Section 309. Hand-operated metering faucets shall SB-2011-E SB-2011-E-BN SC-3004-LD-E S-8729-CA-E remain open for 10 seconds minimum. S-8829-CA-E SECTION 309 OPERABLE PARTS: SB-1711-E SB-1711-E-BN SC-3044-LD-E S-9100-CA-E S-9200-CA-E HEIGHT: Height ranges as outlined in section 308 of the standard apply. S-9101-CA-E S-9201-CA-E OPERATION: Operable Parts shall be operable with one hand and shall SB-1721-E SB-1721-E-BN S-9010-CA-E S-9110-CA-E not require tight grasping, pinching or twisting of the wrist. The force required S-9210-CA-E to activate operable parts shall be 5.0 pounds (22.2 N) maximum. SB-2111-E S-8700-CA-E S-9111-CA-E SPEAKMAN FAUCET SOLUTIONS: SB-2111-LD-BO S-8800-CA-E S-8701-CA-E S-8801-CA-E S-9211-CA-E SC-3084-LD-E S-8710-CA-E S-9112-CA-E Faucets S-8810-CA-E S-8711-CA-E S-9212-CA-E SB-2401 SB-2401-BN SB-1021-E SB-1021-E-BN SC-4072-E-LD S-8811-CA-E S-8712-CA-E S-9117-CA-E S-9217-CA-E S-8812-CA-E S-9118-CA-E SB-2421 SB-2421-BN SB-1311-E SC-4074-E-LD S-8717-CA-E S-9218-CA-E S-9120-CA-E S-8817-CA-E S-9220-CA-E S-8718-CA-E S-9121-CA-E SB-1621-E-PC SB-1321-E SC-5724-E S-8818-CA-E S-8720-CA-E S-9221-CA-E S-9122-CA-E S-8820-CA-E S-8721-CA-E S-9222-CA-E SB-1003-E SB-1003-E-BN SB-1811-E SB-1811-E-BN SC LD-E S-8821-CA-E S-8722-CA-E S-8822-CA-E S-9127-CA-E S-9227-CA-E S-9128-CA-E S-9228-CA-E SC LD-E S-8727-CA-E S-9129-CA-E S-9229-CA-E S-8827-CA-E ADA PRODUCT TRAINING PG. 4 Specs are for reference only. Please refer to ADA.gov for the latest requirements.

5 ADA BATHTUB COMBINATIONS 607 Bathtubs S: Grab bars shall comply with Section 609 and shall be provided in accordance with section & There are two types of Bathtubs covered: BATHTUB WITH PERMANENT SEATS Back Wall: Two horizontal grab bars shall be provided on the back wall, First one complying with Section SHOWER HOSE 15 max. with permanent seats Second located 8 minimum and 10 maximum above the rim of the bathtub. Each grab bar shall be located 15 maximum from the head end wall & extend to 12 maximum from the control end wall min. 59 min. 12 max. 24 min. 24 max. without permanent seats : CONTROL END WALL: Control end wall grab bars shall comply with Section EXCEPTION: An L-shaped continuous grab bar of equivalent dimensions & positioning shall be permitted to serve the function of separate vertical 18 min. & horizontal grab bars. BATHTUB HORIZONTAL : A horizontal grab bar 24 minimum in length shall be provided on the control end wall beginning near the front edge of the bathtub and extending toward the inside corner of the bathtub VERTICAL : SHOWER FIG /2 A vertical grab bar 18 minimum in length shall be provided on the control end wall 3 minimum & 6 above the horizontal grab bar, and 4 inches (100 mm) maximum inward from the front edge of the bathtub. ADA PRODUCT TRAINING PG. 5 Specs are for reference only. Please refer ADA.gov for the latest requirements.

6 ADA BATHTUB COMBINATIONS 12 max (305 mm) 15 max (380 mm) BATHTUB WITHOUT PERMANENT SEATS: For bathtubs without permanent seats, grab bars complying with Section shall be provided BACK WALL. Two horizontal grab bars shall be provided on the back wall. BACK WALL First one complying with Section and the other Control END WALL 24 min (610 mm) 6 (150 mm) END WALL BATHTUB PermANENT SEAT HEAD END WALL Second located 8 minimum and 10 maximum above the rim of the bathtub. Each grab bar shall be 24 minimum in length, located 24 maximum from the head end wall & extend to 12 maximum from the control end wall Control End Wall. Control end wall grab bars shall comply with Section max (100 mm) FIG Head End Wall. A horizontal grab bar 12 minimum in length shall be provided on the head end wall at the front edge of the bathtub CONTROLS: Controls (other than drain stoppers) shall be provided on an end wall, located between the bathtub rim & grab bar, & between the open side of the bathtub & the centerline of the width 12 max (305 mm) 24 min (610 mm) 24 max (610 mm) of the bathtub. Controls shall comply with Section BACK WALL HAND SHOWER: Control END WALL 24 min (610 mm) 6 (150 mm) 4 max (100 mm) END WALL BATHTUB FIG SEAT HEAD END WALL 12 min. (305 mm) A hand shower with a hose 59 minimum in length, that can be used as both a fixed shower head and as a hand shower, shall be provided. The hand shower shall have a control with a non-positive shut-off feature. Where provided, an adjustable-height hand shower mounted on a vertical bar shall be installed so as to not obstruct the use of grab bars. ADA PRODUCT TRAINING PG. 6 Specs are for reference only. Please refer to ADA.gov for the latest requirements.

7 ADA BATHTUB COMBINATIONS Shower/Tub Applications SPEAKMAN SHOWER/TUB SOLUTIONS: SM-X490-ADA-P combinations are intended for shower/tub applications. X in model number above allows you to designate collection, (I.E. 1 is Neo) These bundles include the following (shown in Neo style): SHOWER ARM AND FLANGE, S HAND SHOWER with Hose and bracket, VS PAUSE/TRICKLE ADAPTER non-posistive shut-off, VS-156. S-2540 Shower Arm and Flange Bracket VS-3010 Hand Shower with Hose VS-153-ADA Slide Bar ADA SLIDE BAR: VS-153-ADA. Please note an ADA Slide bar is NOT the same as a Grab Bar. The Slide bar ONLY meets the pull force requirement of the ADA Spec. VS-156 Pause/Trickel Adapter ADA Bathrooms still need to have ADA Grab Bars included as the bar needs to be free from obstructions that may prevent someone from being able to grab the bar. DIVERTER PRESSURE BALANCE SHOWER VALVE with integral stops and Valve Trim: the small diverter handle on the valve trim diverts the water to either the hand shower or tub spout. SM-1400-P. TUB SPOUT, S WHEN TO SPEC: SM-X490-ADA-P Packages: when the project is a shower/tub combination. S-1557 Tub Spout SM-1400-P Diverter Pressure Balance Shower Valve ADA PRODUCT TRAINING PG. 7 Specs are for reference only. Please refer ADA.gov for the latest requirements.

8 ADA BATHTUB COMBINATIONS Shower/Tub Applications SPEAKMAN SHOWER/TUB SOLUTIONS: There are no pre-packaged combinations for ADA with two shower heads and a tub spout. The following items can be ordered to make up a package (Shown in Neo style): SHOWER ARM AND FLANGE, S FIXED SHOWERHEAD, S SHOWER ELBOW connection point for Hand Shower to water supply behind the wall, VS-155. HAND SHOWER with Hose, VS PAUSE/TRICKLE ADAPTER non-posistive shut-off, VS-156. SLIDE BAR: VS-153-ADA. Please note an ADA Slide bar is NOT the same as a Grab Bar. The Slide bar ONLY meets the pull force requirement of the ADA Spec. S-2540 Shower arm and flange S-3010 Fixed Showerhead VS-155 Shower Elbow S-1183 Transfer Valve VS-3010 Hand Shower with Hose VS-153-ADA Slide Bar VS-156 Pause/Trickel Adapter ADA Bathrooms still need to have ADA Grab Bars included as the bar needs to be free from obstructions that may prevent someone from being able to grab the bar. TRANSFER VALVE, S DIVERTER PRESSURE BALANCE SHOWER VALVE with integral stops and Valve Trim: the small diverter handle on the valve trim diverts the water to either the hand shower or tub spout. SM-1400-P. TUB SPOUT, S S-1557 Tub Spout SM-1400-P Diverter Pressure Balance Shower Valve WHEN TO SPEC: when you have an ADA application with both a hand shower and fixed showerhead with Tub. ADA PRODUCT TRAINING PG. 8 Specs are for reference only. Please refer to ADA.gov for the latest requirements.

9 ADA BATHTUB COMBINATIONS Shower/Tub Applications SPEAKMAN SHOWER/TUB SOLUTIONS: There are no pre-packaged combinations for ADA with two shower heads and a tub spout. The following items can be ordered to make up a package(shown in Neo style): SHOWER ARM AND FLANGE, S FIXED SHOWERHEAD, S SHOWER ELBOW connection point for Hand Shower to water supply behind the wall, VS-155. HAND SHOWER with Hose, VS PAUSE/TRICKLE ADAPTER non-posistive shut-off, VS-156. SLIDE BAR: VS-153-ADA. Please note an ADA Slide bar is NOT the same as a Grab Bar. The Slide bar ONLY meets the pull force requirement of the ADA Spec. S-2540 Shower arm and flange S-3010 Fixed Showerhead VS-155 Shower Elbow S-1183 Transfer Valve VS-3010 Hand Shower with Hose VS-153-ADA Slide Bar VS-156 Pause/Trickel Adapter ADA Bathrooms still need to have ADA Grab Bars included as the bar needs to be free from obstructions that may prevent someone from being able to grab the bar. TRANSFER VALVE, S PRESSURE BALANCE SHOWER VALVE with integral stops and valve trim, SM-1000-P. DIVERTER TUB SPOUT, S WHEN TO SPEC: when you have an ADA application with both a hand shower and fixed showerhead with Tub. S-1558 Diverter Tub Spout SM-1000-P Pressure Balance Shower Valve ADA PRODUCT TRAINING PG. 9 Specs are for reference only. Please refer ADA.gov for the latest requirements.

10 ADA SHOWER COMPARTMENT 608 Shower Compartments: There are several types of shower compartments covered by Section S: Grab bars shall comply with Section 609 & shall be provided in accordance with Section Where multiple grab bars are used, required horizontal grab bars shall be installed at the same height above the floor TRANSFER-TYPE SHOWERS: Grab bars for transfer type showers shall comply with Section HORIZONTAL S. Horizontal grab bars shall be provided across 6 (150 mm) the control wall and on the back wall to a point 18 from the control wall. BACK WALL VERTICAL. A vertical grab bar 18 minimum in length shall be provided on the control end wall 3 minimum & 6 maximum above the horizontal grab 6 (150 mm) bar, and 4 maximum inward from the front edge of the shower STANDARD ROLL-IN-TYPE SHOWERS: END WALL SEAT END WALL Grab bar shall be provided on the back wall beginning at the edge of the seat. Grab bars shall not be provided above the seat. Back wall grab bar shall extend the length of the wall but shall not be required to FIG exceed 48 in length. Where a side wall is provided opposite the seat within 72 of the seat wall, a grab bar shall be provided on the side wall opposite the seat. The side wall grab bar shall extend the length of the wall but shall not be required to exceed 30 in length. Grab bars shall be 6 maximum from the adjacent wall. ADA PRODUCT TRAINING PG. 10 Specs are for reference only. Please refer to ADA.gov for the latest requirements.

11 with permanent seats ADA SHOWER COMPARTMENT 18 min. 9 min. 12 max. 24 min. 24 max. without permanent seats Fig ALTERNATE ROLL-IN-TYPE SHOWERS: 6 (150 mm) 6 (150 mm) BACK WALL 6 (150 mm) 6 (150 mm) Grab bars shall be provided on the back wall & the end wall adjacent to the seat. 18 min. Grab bars shall not be provided above the seat. Grab bars shall be 6 maximum from the adjacent wall Controls & Hand Showers: Controls and hand showers shall comply with Sections & TRANSFER-TYPE SHOWERS: BATHTUB SHOWER Controls & hand shower shall be located: Fig /2 1. On the control wall opposite the seat. 2. At a height of 38 minimum and 48 maximum above the shower floor maximum, from the centerline of the control wall toward the shower opening. 6 6 (150 (150 mm) mm) END WALL END WALL GRAB BAR SEAT SEAT BACK WALL FIG FIG SIDE WALL SIDE WALL STANDARD ROLL-IN SHOWERS: Controls & hand shower shall be located on the back wall above the grab bar 48 maximum above the shower floor and 16 minimum & 27 maximum from the end wall behind the seat. TOWEL RACK ALTERNATE ROLL-IN SHOWERS: Robe Hook 42 min. BACK WALL 27 max (685 mm) SPACE FOR HAND SHOWER AND CONTROL 16 max (405 mm) Controls & hand shower shall be located 38 minimum & 48 maximum above the shower floor. In alternate roll-in showers with controls & hand shower located on the end wall adjacent to the seat: Controls & hand shower shall be 27 maximum from the seat wall. In alternative roll-in showers with TOILET controls and hand shower located on the back wall opposite the seat: SEAT Above Grab Bar 48 max (1220 mm) Controls and hand shower shall be located within 15, left of right, of the centerline of the seat. BATHROOM ADA PRODUCT TRAINING PG. 11 Fig FIG Fig Specs are for reference only. Please refer ADA.gov for the latest requirements.

12 ADA BATHTUB COMBINATIONS HAND SHOWERS: A hand shower with a hose 59 minimum in length, that can be used both as a fixed Shower/Tub Diagram shower head & as a hand shower, shall be provided. The hand shower shall have a control with a non-positive shut-off feature. Where provided, an adjustable-height hand shower mounted on a vertical bar shall be installed so as to not obstruct the use of grab bars. EXCEPTION: In other than Accessible units and Type A units, a fixed shower head located 48 inches (1220 mm) maximum above the shower floor shall be permitted in lieu of a hand shower. SPEAKMAN SHOWERING SOLUTIONS: SHOWER HOSE 59 min. Hand Showers VS-1240 VS-1240-BN VS-1240-E2 VS-1240-BN-E2 VS-3010 VS-3010-BN VS-3010-E2 VS-3010-BN-E2 VS-3011 VS-3011-BN VS-3011-E2 VS-3011-BN-E2 Hand Showers VS-142 VS-145 VS-157 VS-157-BN Other VS-156 VS-156-BN VS-100-PC FIG ADA PRODUCT TRAINING PG. 12 Specs are for reference only. Please refer to ADA.gov for the latest requirements.

13 ADA SHOWER COMBINATIONS Shower Applications SPEAKMAN SHOWER SOLUTIONS: There are no pre-packaged combinations for ADA with two shower heads. The following items can be ordered to make up a package (Shown in Neo style): SHOWER ARM AND FLANGE, S FIXED SHOWERHEAD, S SHOWER ELBOW connection point for Hand Shower to water supply behind the wall, VS-155. HAND SHOWER with Hose, VS PAUSE/TRICKLE ADAPTER, VS-156. SLIDE BAR: VS-153-ADA. Please note an ADA Slide bar is NOT the same as a Grab Bar. The Slide bar ONLY meets the pull force requirement of the ADA Spec. S-2540 Shower arm and flange S-3010 Fixed Showerhead VS-155 Shower Elbow VS-3010 Hand Shower with Hose VS-153-ADA Slide Bar VS-156 Pause/Trickel Adapter ADA Bathrooms still need to have ADA Grab Bars included as the bar needs to be free from obstructions that may prevent someone from being able to grab the bar. DIVERTER PRESSURE BALANCE SHOWER VALVE Integral diverter allows switching between the fixed and hand held showers, SM-1400-P. WHEN TO SPEC: when you have an ADA application with both a hand shower and fixed showerhead, no tub. SM-1400-P Diverter Pressure Balance Shower Valve ADA PRODUCT TRAINING PG. 13 Specs are for reference only. Please refer ADA.gov for the latest requirements.

14 ADA SHOWER COMBINATIONS Shower Applications SPEAKMAN SHOWER SOLUTIONS: There are no pre-packaged combinations for ADA when two shower heads are desired. The following items can be ordered to make up a ADA two shower head package: (Shown in Neo style). SHOWER ARM AND FLANGE, S FIXED SHOWERHEAD, S SHOWER ELBOW connection point for Hand Shower to water supply behind the wall, VS-155. HAND SHOWER with Hose, VS S-2540 Shower arm and flange S-3010 Fixed Showerhead VS-155 Shower Elbow VS-3010 Hand Shower with Hose VS-153-ADA Slide Bar PAUSE/TRICKLE ADAPTER, VS-156. SLIDE BAR: VS-153-ADA. Please note an ADA Slide bar is NOT the same as a Grab Bar. The Slide bar ONLY meets the pull force requirement of the ADA Spec. S-1183 Transfer Valve VS-156 Pause/Trickel Adapter ADA Bathrooms still need to have ADA Grab Bars included as the bar needs to be free from obstructions that may prevent someone from being able to grab the bar. TRANSFER VALVE diverts the water from fixed to hand shower, S PRESSURE BALANCE SHOWER VALVE with integral stops and Valve Trim, SM-1000-P. SM-1000-P Pressure Balance Shower Valve WHEN TO SPEC: this is the direction to go in when you have an ADA application with both a hand shower and fixed showerhead, no tub. ADA PRODUCT TRAINING PG. 14 Specs are for reference only. Please refer to ADA.gov for the latest requirements.

15 ADA SHOWER COMBINATIONS Shower Applications SPEAKMAN SHOWER/TUB SOLUTIONS: SM-X090-ADA-P combinations are intended for shower/tub applications. X in model number above allows you to designate collection, (I.E. 1 is Neo) These bundles include the following: SHOWER ARM AND FLANGE, S HAND SHOWER with Hose and bracket, VS ADA SLIDE BAR: VS-153-ADA, Please note an ADA Slide bar is NOT the same as a Grab Bar. The Slide bar ONLY meets the pull force requirement of the ADA Spec. ADA Bathrooms still need to have ADA Grab Bars included as the bar needs to be free from obstructions that may prevent someone from being able to grab the bar. S-2540 Shower Arm and Flange Bracket VS-3010 Hand Shower with Hose VS-153-ADA Slide Bar VS-156 Pause/Trickel Adapter PAUSE/TRICKLE ADAPTER, VS-156. PRESSURE BALANCE SHOWER VALVE with integral stops and Valve Trim, SM-1000-P. DIVERTER TUB SPOUT: Diverter on spout controls water flow from either the hand shower or the tub spout, S WHEN TO SPEC: SM-X090-ADA-P Packages: when the project is a shower/tub combination. SM-1000-P Pressure Balance Shower Valve S-1558 Diverter Tub Spout ADA PRODUCT TRAINING PG. 15 Specs are for reference only. Please refer ADA.gov for the latest requirements.

16 ADA S 609 Grab Bars: Grab bars in accessible toilet or bathing facilities shall comply with Section CROSS SECTION: Circular Cross Section: Bars with circular cross section shall have outside diameter of 1-1/4 minimum & 2 maximum Noncircular Cross Section: Bars with noncircular cross section shall have cross section dimension of 2 maximum & a perimeter dimension of 4 minimum & 4.8 maximum Spacing: Space between wall & grab bar shall be 1.5 Space between grab bar & projecting objects below and at the ends of grab bar shall be 1.5 minimum. Space above the bar & projecting objects shall be 12 minimum SURFACE HAZARDS: Grab bars & any wall or other surfaces adjacent to grab bars, shall be free of sharp or abrasive elements. Edges shall be rounded FITTINGS: Grab bars shall not rotate within their fittings INSTALLATION AND CONFIGURATION: Grab bars shall be installed in any manner that provides a gripping surface at the locations specified in this standard & does not obstruct the clear floor space. Horizontal & vertical grab bars shall be permitted to be separate bars, a single piece bar, or combination thereof STRUCTURAL STRENGTH: Allowable stresses shall not be exceeded for materials used where a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the grab bar, fastener mounting device, or supporting structure Position of Grab Bars General Grab bars shall be installed in a horizontal position, 33 minimum & 36 maximum above the floor measured to the top of the gripping surface or shall be installed as required by Items 1 through 3: The lower grab bar on the back wall of a bathtub shall comply with Section or Vertical grab bars shall comply with Sections , , & / mm - 51 mm perimiter 100 mm mm 2 max. 51 mm Grab bars at water closets primarily for children s use shall comply with Section FIG ADA PRODUCT TRAINING PG. 16 Specs are for reference only. Please refer to ADA.gov for the latest requirements.

17 ADA S Speakman Grab Bar Solutions: AVAILABLE IN 3 LENGTHS: 24 INCHES, SA-1X INCHES, SA-1X INCHES, SA-1X09-48 SA Neo Polished Chrome * Custom lengths available per request TWO STYLES: NEO, SA-1009-XX RAINIER, SA-1309-XX TWO FINISHES STANDARD: SA Rainier Brushed Nickel POLISHED CHROME BRUSHED NICKEL, -BN * Specialty finishes available per request ADA S SA SA BN SA SA BN SA SA BN ADA S SA SA BN SA SA BN SA SA BN ADA PRODUCT TRAINING PG. 17 Specs are for reference only. Please refer ADA.gov for the latest requirements.

18 For additional assistance or service please contact: SPEAKMAN Company 400 Anchor Mill Road New Castle, DE

California Building Code Effective January 2014 HOUSING ACCESSIBILITY BATHING FACILITIES Title 24, Part A

California Building Code Effective January 2014 HOUSING ACCESSIBILITY BATHING FACILITIES Title 24, Part A One common use bathing facilities such as bathtubs or showers are provided for residents or guests, at least one of each type of fixture in each facility and not less than 1% of all fixtures shall comply

More information

SECTION SHOWER AND BATH ENCLOSURES. Display hidden notes to specifier by using Tools / Options / View / Hidden Text.

SECTION SHOWER AND BATH ENCLOSURES. Display hidden notes to specifier by using Tools / Options / View / Hidden Text. SECTION 10185 SHOWER AND BATH ENCLOSURES Display hidden notes to specifier by using Tools / Options / View / Hidden Text. PART 1 GENERAL 1.1 SECTION INCLUDES A. Bathtub wall enclosures. B. Shower wall

More information

CURRENT ADA AND ICC COMPLIANCE DATA AN INTRODUCTION TO BOBRICK S ADA- COMPLIANT PRODUCTS, AS WELL AS BASIC MOUNTING HEIGHTS AND REACH RANGES

CURRENT ADA AND ICC COMPLIANCE DATA AN INTRODUCTION TO BOBRICK S ADA- COMPLIANT PRODUCTS, AS WELL AS BASIC MOUNTING HEIGHTS AND REACH RANGES CURRENT ADA AND ICC COMPLIANCE DATA AN INTRODUCTION TO BOBRICK S ADA- COMPLIANT PRODUCTS, AS WELL AS BASIC MOUNTING HEIGHTS AND REACH RANGES CURRENT ADA AND ICC COMPLIANCE DATA AN INTRODUCTION TO BOBRICK

More information

ACCESSIBILITY CHECKLIST

ACCESSIBILITY CHECKLIST ACCESSIBILITY CHECKLIST WASHINGTON STATE Northwest ADA Center University of Washington 6912 220 th Street SW Suite 105 Mountlake Terrace, WA 98043 Toll Free (800) 949-4232 TTD (425) 771-7426 www.nwadacenter.org

More information

Chapter 5. General Site and Building Elements

Chapter 5. General Site and Building Elements AMERICAN NATIONAL STANDARD Chapter 5. General Site and Building Elements Chapter 5. General Site and Building Elements 501 General 501.1 Scope. General site and building elements required to be accessible

More information

Accessible Swimming Pools and Spas

Accessible Swimming Pools and Spas Accessible Swimming Pools and Spas Introduction Accessible Swimming Pools and Spas Accessible Routes Types of Facilities and Required Means of Entry into the Water Pool Lifts Sloped Entries Transfer Walls

More information

sensible sophistication

sensible sophistication d e s i g n e r f a u c e t s & a c c e s s o r i e s sensible sophistication A rare collection of artistic expressions for the distinctive home environment. Mirabelle is a fusion of form, craftsmanship

More information

DESIGNER FAUCETS & ACCESSORIES

DESIGNER FAUCETS & ACCESSORIES DESIGNER FAUCETS & ACCESSORIES sensible sophistication A rare collection of artistic expressions for the distinctive home environment. Mirabelle is a fusion of form, craftsmanship and function designed

More information

CHAPTER 5: GENERAL SITE AND BUILDING ELEMENTS

CHAPTER 5: GENERAL SITE AND BUILDING ELEMENTS CHAPTER 5: GENERAL SITE AND BUILDING ELEMENTS 501 General 501.1 Scope. The provisions of Chapter 5 shall apply where required by Chapter 2 or where referenced by a requirement in this document. 502 Parking

More information

ADA Access Standards for Swimming Pools, Wading Pools, and Spas

ADA Access Standards for Swimming Pools, Wading Pools, and Spas ADA Access Standards for Swimming Pools, Wading Pools, and Spas The sports, places of amusement, and outdoor developed areas subcommittees each provided recommendations in this area. The recommendations

More information

City of Los Angeles Department of Building & Safety Disabled Access Section Supplemental Plan Review Checklist No. 8 RECREATION FACILITIES

City of Los Angeles Department of Building & Safety Disabled Access Section Supplemental Plan Review Checklist No. 8 RECREATION FACILITIES AMUSEMENT RIDES, BOAT SLIPS, BOWLING LANES, COURT SPORTS, FISHING PIERS Plan Check No. 1. Amusement rides required to comply with 11B-234, Amusement Rides shall provide accessible routes in accordance

More information

ADA COMPLIANCE CHECKLIST (RESTAURANT) Meet Fail N/A. Parking Lot

ADA COMPLIANCE CHECKLIST (RESTAURANT) Meet Fail N/A. Parking Lot ADA COMPLIANCE CHECKLIST (RESTAURANT) Parking Lot Tow away warning at entrance to lot Accessible spaces - minimum 1, and at least 1 for each 25 spaces (e.g., 26 spaces requires 2 accessible spaces) Accessible

More information

REVIEW OF ACCESSIBILITY FEATURES

REVIEW OF ACCESSIBILITY FEATURES Developed by London's Municipal Accessibility Advisory Committee 1 REVIEW OF ACCESSIBILITY FEATURES Updated 2008-01-01 According to FADS 2007 Page 1 of 20 Developed by London's Municipal Accessibility

More information

Circular Turning Space. 8 Significant Changes to the ICC A

Circular Turning Space. 8 Significant Changes to the ICC A 8 Significant Changes to the ICC A117.1 2017 304.3.1 Circular Turning Space CHANGE TYPE: Modification CHANGE SUMMARY: Within new buildings, the size of a circular turning space has been increased from

More information

Banyan Air Service November 18, 2011 AVE Aviation and Commerce Center Building 1 Miami, FL

Banyan Air Service November 18, 2011 AVE Aviation and Commerce Center Building 1 Miami, FL SECTION 10801 - TOILET AND BATH ACCESSORIES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions apply to this Section.

More information

DIVISION 10 SPECIALTIES

DIVISION 10 SPECIALTIES DIVISION 10 SPECIALTIES UCSC Campus Standards Handbook Chalkboards and Tackboard Standards 10100 1 SECTION 10100: CHALKBOARD AND TACKBOARD STANDARDS A. Verify all locations of chalkboards and bulletin

More information

Location: Cariboo, One Hundred Mile House, Cariboo Chilcotin Coast - Provincial : Park (Heritage Discovery Circle Route)

Location: Cariboo, One Hundred Mile House, Cariboo Chilcotin Coast - Provincial : Park (Heritage Discovery Circle Route) Mt Robson Visitors Centre Information Date of Audit: 2016-08-04 Park Name: Emerald Bay Sunset View Key Features: Camping,Picnic_Site,Beach,Trails,Playground,Fishing Location: Cariboo, One Hundred Mile

More information

Aquatic Facility Evaluation City of Merriam, Kansas. Kyle A. McCawley, P.E. Larkin Aquatics 4/9/2014

Aquatic Facility Evaluation City of Merriam, Kansas. Kyle A. McCawley, P.E. Larkin Aquatics 4/9/2014 2014 Aquatic Facility Evaluation City of Merriam, Kansas Kyle A. McCawley, P.E. Larkin Aquatics 4/9/2014 Table of Contents Introduction... 2 Executive Summary... 2 Applicable Codes and Standards... 3 Facility

More information

Standards vs. Guidelines. Public Right-of Way Accessibility Guidelines (PROWAG)

Standards vs. Guidelines. Public Right-of Way Accessibility Guidelines (PROWAG) www.access-board.gov Public Right-of Way Accessibility Guidelines (PROWAG) Juliet Shoultz, P.E Transportation Systems Engineer US Access Board Standards vs. Guidelines Guidelines are developed by the Access

More information

California Conference of Directors of Environmental Health Recreational Health Technical Advisory Committee September 17, 2003

California Conference of Directors of Environmental Health Recreational Health Technical Advisory Committee September 17, 2003 California Conference of Directors of Environmental Health Recreational Health Technical Advisory Committee September 17, 2003 RECREATIONAL WATER PARKS GUIDELINES Definitions. ACTIVITY POOL means a pool

More information

Welcome to the AccessibilityOnline Webinar Series

Welcome to the AccessibilityOnline Webinar Series Welcome to the AccessibilityOnline Webinar Series A collaborative program between the ADA National Network and the US Access Board The Session is Scheduled to begin at 2:30pm Eastern Time We will be testing

More information

table of contents bath accessories Cable Drains...19 Cover Plates Drains Drain Conversion Kits...20

table of contents bath accessories Cable Drains...19 Cover Plates Drains Drain Conversion Kits...20 table of contents kitchen accessories Air Gaps.............3 Basket Strainers.........3 Disposal Flanges....... 3-4 Faucet Hole Covers....... 4 Soap & Lotion Dispensers.... 4 Water Dispensers........ 4

More information

Unit # ± 5,514 SF Width ± 85' Depth ± 68' Plans produced by: ID Plans 10/12/2016 (813)

Unit # ± 5,514 SF Width ± 85' Depth ± 68' Plans produced by: ID Plans 10/12/2016 (813) ±50' Lease Line ±20' ±15' Lease Outline Drawing ±65' Lease Line ±68' Lease Line Sunnymead Plaza 24949 Sunnymead Blvd., Moreno Valley, CA 92553 Unit # 24949 ± 5,514 SF Width ± 85' Depth ± 68' Plans produced

More information

- Written price quotations are valid for 30 days from the date of the quote unless otherwise noted.

- Written price quotations are valid for 30 days from the date of the quote unless otherwise noted. SPECIFICATIONS - All material is solid brass with a #8 mirror finish unless otherwise noted. - All material sold by length is priced in one foot increments. ORDERING PROCEDURE - Use a Purchase Order number.

More information

ada compliance swimming pool Compliance guide

ada compliance swimming pool Compliance guide swimming pool Compliance guide accessibility equipment pool lifts S.R. Smith is your source for 3rd party tested and ADA compliant pool lifts that work for virtually any pool design or application. From

More information

Technical data sheet. Type overview. Technical data. Safety notes. T5-R2.. Open-close en v Subject to changes 1 / 3

Technical data sheet. Type overview. Technical data. Safety notes.   T5-R2.. Open-close en v Subject to changes 1 / 3 Technical data sheet R2.. Open-close ball valves, 2-way, with internal thread for open and closed cold and warm water systems for shut-off functions on the water side and 2-point controls in air-handling

More information

Decorative Accessories Guide

Decorative Accessories Guide Decorative Accessories Guide Monogram Brass is a trademark of Ferguson Enterprises, Inc. Monogram Brass Finishes Brushed Nickel* (BN) Oil Rubbed Bronze (ORB) Polished Brass* (PB) Chrome (CP) Biscuit (BISC)

More information

Palmer township, Pennsylvania. Pool & Fence Details Based on the 2009 International Residential Code (Designed and Printed January 2012)

Palmer township, Pennsylvania. Pool & Fence Details Based on the 2009 International Residential Code (Designed and Printed January 2012) Palmer township, Pennsylvania Pool & Fence Details Based on the 2009 International Residential Code (Designed and Printed January 2012) CONTENTS General Information... 2 Prohibited Barrier Locations..

More information

POOL AND SPA REPLASTERING AND/OR REMODELING REQUIREMENTS

POOL AND SPA REPLASTERING AND/OR REMODELING REQUIREMENTS POOL AND SPA REPLASTERING AND/OR REMODELING REQUIREMENTS Effective January 1, 2017 PLAN SUBMITTAL Any person proposing to renovate, replaster, reconstruct or alter a public pool or its ancillary facilities,

More information

Stand-N-Fish FULL DETAIL INSTALLATION INSTRUCTIONS

Stand-N-Fish FULL DETAIL INSTALLATION INSTRUCTIONS 1 Stand-N-Fish FULL DETAIL INSTALLATION INSTRUCTIONS Thank you for purchasing the incredible new Stand-N-Fish Kayak Fishing System. Once installed on your kayak the Stand-N-Fish will take your kayak fishing

More information

Palmer township, Pennsylvania. Pool Fence Details Based on the 2009 International Residential Code (Designed and Printed January 2012)

Palmer township, Pennsylvania. Pool Fence Details Based on the 2009 International Residential Code (Designed and Printed January 2012) Palmer township, Pennsylvania Pool Fence Details Based on the 2009 International Residential Code (Designed and Printed January 2012) CONTENTS General Information... 2 Above-Ground Pool. 4 Barrier Requirements....

More information

Decorative Accessories Guide

Decorative Accessories Guide Decorative Accessories Guide Monogram Brass is a trademark of Ferguson Enterprises, Inc. Monogram Brass Finishes Brushed Nickel* (BN) Oil Rubbed Bronze (ORB) Polished Brass* (PB) Chrome (CP) Biscuit (BISC)

More information

SNT Installation of a SNT Walk In Bath Tub follows the basic steps below. SNT: $2,248.00

SNT Installation of a SNT Walk In Bath Tub follows the basic steps below. SNT: $2,248.00 PRICE: $5,862.00 SNT WHIRLPOOL ADA WALK IN TUB Want a walk-in bathtub that has all the bells and whistles? Need a safe solution for bathing that's also luxurious and relaxing? The Sanctuary Whirlpool Duo

More information

Engineering Excellence. Installation Guide

Engineering Excellence. Installation Guide Engineering Excellence Installation Guide Two Handle Kitchen Faucet: 2DM200 2DM201 This product meets the following standards: ASME A112.18.1 ANSI A117.1 ANSI / NSF 61, SECTION 9 CUPC / IAPMO LISTED /

More information

dpd Seattle Permits Tip Getting a Grip on Handrails PURPOSE OF HANDRAILS

dpd Seattle Permits Tip  Getting a Grip on Handrails PURPOSE OF HANDRAILS dpd Department of Planning and Development Tip 319 Seattle Permits part of a multi-departmental City of Seattle series on getting a permit Getting a Grip on Handrails Updated March 2, 2007 PURPOSE OF HANDRAILS

More information

THE KEENEY MANUFACTURING COMPANY

THE KEENEY MANUFACTURING COMPANY Brass Tubular P Traps 1-8 Repair Traps 8-9 S Traps 9-11 Sink Traps 11-15 Bath Traps 15 Washing Machine Traps 16 J Bends 16-17 Sink Trap J Bends 17-18 Wall Bends 19 Floor Tubes 19 Center Outlet Continuous

More information

BASIN AND WALL MIXER INSTALLATION INSTRUCTIONS

BASIN AND WALL MIXER INSTALLATION INSTRUCTIONS BASIN AND WALL MIXER INSTALLATION INSTRUCTIONS IMPORTANT INFORMATION IMPORTANT All tapware and showers to be installed by a licensed plumber and to Australian Standards. Fit tempering and pressure reduction

More information

AKIT1901LM (Metal levers) AKIT1901XM (Cross Handles)

AKIT1901LM (Metal levers) AKIT1901XM (Cross Handles) PALLADIAN EXPOSED TUB SET WITH HANDSHOWER AKIT1901LM (Metal levers) AKIT1901XM (Cross Handles) COLORS/FINISHES WARRANTY FEATURES Palladian metal levers or cross handles Floor mounted exposed two handle

More information

Storage Systems and Accessories

Storage Systems and Accessories Storage Systems and Accessories High Pressure Air and Inert Gases 4500-6000 PSIG DOT and ASME Cylinders High Pressure Storage Systems If an application requires storage, either in the form of a single

More information

SWIMMING POOLS/SPAS/HOT TUBS PLAN REVIEW GUIDE SHEET

SWIMMING POOLS/SPAS/HOT TUBS PLAN REVIEW GUIDE SHEET SWIMMING POOLS/SPAS/HOT TUBS PLAN REVIEW GUIDE SHEET Sect. 106-748, City Code of Ordinances: Regulations are applicable to both above and inground swimming pools, spas and hot tubs. POOL PLACEMENT Measurement

More information

Building Code Guidelines For Home Pools

Building Code Guidelines For Home Pools Building Code Guidelines For Home Pools KEEP YOUR POOL SAFE Department of Development and Permits 306 Cedar Road, City Hall 2 nd Floor Chesapeake, VA 23322 Phone: (757) 382-6018 E-mail: develop-permits@cityofchesapeake.net

More information

Field guide for Accessible Public Rights-of-Way Edition

Field guide for Accessible Public Rights-of-Way Edition Field guide for Accessible Public Rights-of-Way 2015 Edition BRIEFING MEMO SUBJECT: Department of Justice/Department of Transportation Joint Technical Assistance on Title II of the Americans with Disabilities

More information

KTM OM-2 SPLIT BODY FLOATING BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

KTM OM-2 SPLIT BODY FLOATING BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS Before installation these instructions must be fully read and understood SECTION 1 - STORAGE 1.1 Preparation and preservation for storage All valves should be properly packed in order to protect the parts

More information

Swimming Pool Fence Guide Kodiak Iron

Swimming Pool Fence Guide Kodiak Iron Swimming Pool Fence Guide Kodiak Iron Exceptional Fencing Extraodinary Customer Service BOCA National Building Code (Building Officials and Code Administrators International Inc.) This nonprofit agency

More information

B LCTV_v3 4/27/04 10:54 AM Page 1 Series e700

B LCTV_v3 4/27/04 10:54 AM Page 1 Series e700 Series e700 ADA compliant 1016 listed B125 Certified Self-contained cartridge installs in minutes Cartridge retrofits into all Powers Series 900 Pressure Balancing Valves - Model 3 Integral checkstops

More information

Building Code Guidelines For Home Pools

Building Code Guidelines For Home Pools Building Code Guidelines For Home Pools KEEP YOUR POOL SAFE Department of Inspections 17140 Monument Circle Suite 100 Isle of Wight, Virginia 23397 757-365-6213/6215 CODE REQUIREMENTS FOR SWIMMING POOLS

More information

ADA Library Accessibility Checklist

ADA Library Accessibility Checklist A. LIBRARIES Reading and Study Areas Do at least 5% (but not less than one) of fixed seating, tables, or study carrels have... Clear floor or ground spaces for wheelchairs? Clear space of 60" in diameter

More information

Differential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN

Differential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN Differential Pressure Regulator Type 45-6 Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN Edition March 2008 Contents Contents Page 1 Design and principle of operation...................

More information

Accessible Swimming Pools and Spas. Welcome to the Accessibility Online Webinar Series. Webinar Features

Accessible Swimming Pools and Spas. Welcome to the Accessibility Online Webinar Series. Webinar Features Welcome to the Accessibility Online Webinar Series A collaborative program between the ADA National Network and the US Access Board The Session is Scheduled to begin at 2:30pm Eastern Time We will be testing

More information

Effective Date: May Rev. 6/18/2018- Void After: May Product: Plumbing Fixture Fittings File No. 3489

Effective Date: May Rev. 6/18/2018- Void After: May Product: Plumbing Fixture Fittings File No. 3489 IAPMO Research and Testing, Inc. is a product certification body which tests and inspects samples taken from the supplier's stock or from the market or a combination of both to verify compliance to the

More information

Swimming Pool Plans and Specification Report

Swimming Pool Plans and Specification Report Swimming Pool Plans and Specification Report For TCHD Use Only Date Received by Employee Number: *Plans Received Yes No *$120.00 Plan Review Fee Paid Yes No *Facility Name: Phone: *Address: *Owner: *Phone:

More information

APPENDIX A RECOMMENDED RULES FOR SIZING THE WATER SUPPLY SYSTEMS CHART A-1 FRICTION LOSSES FOR DISK-TYPE WATER METERS 1-1/2"

APPENDIX A RECOMMENDED RULES FOR SIZING THE WATER SUPPLY SYSTEMS CHART A-1 FRICTION LOSSES FOR DISK-TYPE WATER METERS 1-1/2 RECOMMENDED RULES FOR SIZING THE WATER SUPPLY SYSTEMS Because of the variable conditions encountered, it is impractical to lay down definite detailed rules of procedure for determining the sizes of water

More information

ORNAMENTAL CANTILEVER GATE INSTRUCTIONS

ORNAMENTAL CANTILEVER GATE INSTRUCTIONS U.S.A. Patent Number 5,36,83 ORNAMENTAL CANTILEVER GATE INSTRUCTIONS *NOTICE: Ornamental Cantilever Gates are supplied with rolls of 2 mesh safety screening in sufficient quantities to cover the entire

More information

Building Code Guidelines for Residential Pools

Building Code Guidelines for Residential Pools Building Code Guidelines for Residential Pools KEEP YOUR POOL SAFE Department of Development and Permits 306 Cedar Road, City Hall 2 nd Floor Chesapeake, VA 23322 Phone: (757) 382-6018 E-mail: develop-permits@cityofchesapeake.net

More information

POOL BARRIER AMENDMENTS & GUIDELINES: APPENDIX G SWIMMING POOLS, SPAS AND HOT TUBS

POOL BARRIER AMENDMENTS & GUIDELINES: APPENDIX G SWIMMING POOLS, SPAS AND HOT TUBS SECTION AG101 - GENERAL POOL BARRIER AMENDMENTS & GUIDELINES: APPENDIX G SWIMMING POOLS, SPAS AND HOT TUBS AG101.1 General. The requirements of this appendix shall apply to the design and construction

More information

VERTICAL BLADDER TANK

VERTICAL BLADDER TANK Balanced Pressure Proportioning System Reliable Foam System Requiring Only Water Power Perfect For Tight Spaces UL Listed, ASME, National Board Registered Bladder-UL162 Approved, High Tensile Pressure

More information

Series e700 Combination T/P Valve Provides Unsurpassed Protection from Temperature & Pressure

Series e700 Combination T/P Valve Provides Unsurpassed Protection from Temperature & Pressure Series e700 Combination T/P Valve Provides Unsurpassed Protection from Temperature & Pressure Bacteria/Legionella Protection Is Lower Better? The Other Side to the Coin. It s truly a double-edged sword.

More information

Horizontal Bladder Tanks

Horizontal Bladder Tanks DATA SHEET Horizontal Bladder Tanks Features UL Listed and FM Approved for use with various ANSUL proportioners and foam concentrates 175 psi (12.1 bar) maximum allowable working pressure (design pressure)

More information

Fluid Dispensing Systems H O S E R E E L S H O S E S HOSE REELS

Fluid Dispensing Systems H O S E R E E L S H O S E S HOSE REELS Fluid Dispensing Systems H O S E R E E L S H O S E S HOSE REELS HOSE REELS SIGNATURE SERIES H O S E S R E E L S FEATURES & BENEFITS Eight position locking precision die cast latch mechanism, with secure

More information

SECTION WASHROOM ACCESSORIES

SECTION WASHROOM ACCESSORIES Bobrick offers over 750 products for public washroom facilities and five series of toilet partitions. If you are not familiar with the Bobrick product line, please view the Full Catalog at or contact your

More information

GENO -Flushing Compressor Product Data Sheet F 02

GENO -Flushing Compressor Product Data Sheet F 02 GENO -flushing compressor 1988 K Fig. 1: GENO -flushing compressor 1988 K Designated application is suitable for the following fields of application: Flushing of pipes with water/air mix prior to the start-up

More information

New and Upcoming Products Update

New and Upcoming Products Update New and Upcoming Products Update Issue 13 December 14, 2007 As we come to the close of another year, TOTO s momentum remains intact as we prepare to add several new and exciting products to our ever-expanding

More information

STAD-C. Balancing valves DN 15-50

STAD-C. Balancing valves DN 15-50 STAD-C Balancing valves 15-50 IMI TA / Balancing valves / STAD-C STAD-C The STAD-C balancing valve has been specially developed for use in indirect cooling systems but performs just as effectively in refrigerated

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS COUNTER-CURRENT SWIMMING Hurricane Turbo Swim Jet INSTALLATION INSTRUCTIONS PACKET NO.1 With a COUNTER-CURRENT SWIMMING device your swimming pool is no longer a simple man-made lake. It becomes the most

More information

Example Applications of the Proposed Medical Diagnostic Equipment Accessibility Standards

Example Applications of the Proposed Medical Diagnostic Equipment Accessibility Standards Example Applications of the Proposed Medical Diagnostic Equipment Accessibility Standards January 23, 2012 U N I T E D S T A T E S A C C E S S B O A R D A FEDERAL AGENCY COMMITTED TO A C CESSIBLE DESIGN

More information

U.S. Patent No. 7,922,246. Patents Pending

U.S. Patent No. 7,922,246. Patents Pending U.S. Patent No. 7,922,246 Patents Pending 2 Table of Contents Page General Information... 3 Warnings and Cautions... 4 Tools... 6 SmartDock Parts... 6 Initial Set-Up and Adjustment... 7 Select Valve Retaining

More information

FILTER REGULATORS MODEL NO: CAT155 & CAT156 FITTING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS

FILTER REGULATORS MODEL NO: CAT155 & CAT156 FITTING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS FILTER REGULATORS MODEL NO: CAT155 & CAT156 PART NO: 3120169 & 3120170 FITTING & MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS GC0117 INTRODUCTION Thank you for purchasing this CLARKE Filter/Regulator.

More information

TAPS + ACCessories. an everyday luxury

TAPS + ACCessories. an everyday luxury TAPS + ACCessories an everyday luxury Sometimes to get the most out of life, you just have to go with the flow. Posh taps and mixers will help you do just that. They re designed to cope with the demands

More information

Model MTB-ASME Vertical Bladder Tanks

Model MTB-ASME Vertical Bladder Tanks DATA SHEET Model MTB-ASME Vertical Bladder Tanks Features n UL Listed for use with various proportioners and foam concentrates n 175 psi (12.1 bar) maximum allowable working pressure (design pressure)

More information

Model MTB-ASME Horizontal Bladder Tanks

Model MTB-ASME Horizontal Bladder Tanks DATA SHEET Model MTB-ASME Horizontal Bladder Tanks Features n UL Listed and FM Approved for use with various proportioners and foam concentrates n 175 psi (12.1 bar) maximum allowable working pressure

More information

CRANE WITH WINCH USE AND MAINTENANCE MANUAL. Code Rev. Release MD /03

CRANE WITH WINCH USE AND MAINTENANCE MANUAL. Code Rev. Release MD /03 CRANE WITH WINCH Code Rev. Release MD.0.097 0 06/03 USE AND MAINTENANCE MANUAL CONTENTS 1 FOREWORD page 3 1.1 Description of the crane with winch page 3 2 USE OF THE CRANE WITH WINCH page 3 2.1 General

More information

Check with local zoning official for property line distance requirements.

Check with local zoning official for property line distance requirements. RESIDENTIAL POOL PLAN SUBMITTAL GUIDELINES The following guidelines are intended to assist municipal residents with the permit acquisition process with regard to pools, spas and hot tubs for single family

More information

E. Test, and if needed, adjust tips of antenna. 1. Mark will test antennas with meter at ground end of feedline bundle. Will take 10 minutes.

E. Test, and if needed, adjust tips of antenna. 1. Mark will test antennas with meter at ground end of feedline bundle. Will take 10 minutes. Project Steps Overview: A. Prepare: B. Raise up small antenna. C. Raise up large antenna. D. Connect to new bundle of 4-feedlines pulled up from ground. E. Test, and if needed, adjust tips of large antenna.

More information

Model MTB-ASME Vertical Bladder Tanks

Model MTB-ASME Vertical Bladder Tanks DATA SHEET Model MTB-ASME Vertical Bladder Tanks Features n UL Listed for use with various proportioners and foam concentrates n 175 psi (12.1 bar) maximum allowable working pressure (design pressure)

More information

accessible swimming pools & spas

accessible swimming pools & spas amusement rides boating facilities f ishing piers & platforms golf courses miniature golf sports facilities swimming pools & spas accessible swimming pools & spas a summary of ac c e s sibilit y guideline

More information

SECTION BUTTERFLY VALVES

SECTION BUTTERFLY VALVES SECTION 15112 BUTTERFLY VALVES PART 1 GENERAL 1.01 SUMMARY A. All butterfly valves shall be of the tight closing, rubber seated type and fully comply with the latest revision of AWWA Standard C504, Class

More information

appendix a recommended rules For sizing the water supply system PRE-PRINT Chart a 1.2 FriCtion losses For Disk-type water Meters

appendix a recommended rules For sizing the water supply system PRE-PRINT Chart a 1.2 FriCtion losses For Disk-type water Meters recommended rules For sizing the water supply system Because of the variable conditions encountered, it is impractical to lay down definite detailed rules of procedure for determining the sizes of water

More information

APPENDIX A RECOMMENDED RULES FOR SIZING THE WATER SUPPLY SYSTEM CHART A 1.2 FRICTION LOSSES FOR DISK-TYPE WATER METERS 1-1/2"

APPENDIX A RECOMMENDED RULES FOR SIZING THE WATER SUPPLY SYSTEM CHART A 1.2 FRICTION LOSSES FOR DISK-TYPE WATER METERS 1-1/2 RECOMMENDED RULES FOR SIZING THE WATER SUPPLY SYSTEM Because of the variable conditions encountered, it is impractical to lay down definite detailed rules of procedure for determining the sizes of water

More information

KC Series Gas Components and Supply Design Guide

KC Series Gas Components and Supply Design Guide Technical Bulletin KC Series Gas Components and Supply Design Guide GF-1030 General AERCO KC Series gas fired potable water heaters and boilers are modulating input devices that require an adequate volume

More information

Transfer Chain (SA-1002) & Adjustable I-Beam Clamp (SA-1039 or SA-1040) Operating Instructions

Transfer Chain (SA-1002) & Adjustable I-Beam Clamp (SA-1039 or SA-1040) Operating Instructions Transfer Chain (SA-1002) & Adjustable I-Beam Clamp (SA-1039 or SA-1040) Operating Instructions SPIDER Page 1 of 8 702127 Rev A Using Transfer Chain with Adjustable I-Beam Clamp Safety Notes Do not use

More information

Vertical Bladder Tanks

Vertical Bladder Tanks DATA SHEET Vertical Bladder Tanks Features UL Listed and FM Approved for use with various ANSUL proportioners and foam concentrates 175 psi (12.1 bar) maximum allowable working pressure (design pressure)

More information

Hatch cover securing and tightness

Hatch cover securing and tightness (1986) (Rev 1 1996) (Corr.1 June 2000) (Rev.2 July 2005) (Corr.1 Oct 2005) Hatch cover securing and tightness 1. Application 1.1 The following recommendations apply to steel hatch covers that are fitted

More information

Department of Public Works Office of Disability Affairs February 23, 2017 Presented by Mark Zwoyer, PE

Department of Public Works Office of Disability Affairs February 23, 2017 Presented by Mark Zwoyer, PE ADA Ramp Construction Department of Public Works Office of Disability Affairs February 23, 2017 Presented by Mark Zwoyer, PE Agenda Opening Statements/Welcome PROWAG, ADAAG, INDOT and DPW Standards Inspector

More information

Water Weir Flow Controller. Introduction. Safety Precautions. Mounting the Hardware

Water Weir Flow Controller. Introduction. Safety Precautions. Mounting the Hardware 57007-88 Introduction Safety Precautions This instruction sheet describes how to set up and use the Hach (Figure 1). A water weir is a device that raises or diverts water to regulate the flow. Hach s water

More information

User Instruction Manual Fixed Beam Anchor

User Instruction Manual Fixed Beam Anchor Instructions for the following series products: FIXED BEAM ANCHOR Model Numbers: The Ultimate in Fall Protection 2108406 2108407 2108408 2108409 2108410 2108411 User Instruction Manual Fixed Beam Anchor

More information

Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange

Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange Data sheet Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange Description VF 2 VF 3 VF 2 and VF 3 valves provide a quality, cost effective solution for most water and chilled applications.

More information

Agilent 1220 Infinity II LC Mobile Upgrade Kit

Agilent 1220 Infinity II LC Mobile Upgrade Kit Agilent 1220 Infinity II LC Mobile Upgrade Kit Note 1220 Infinity II LC Mobile Upgrade Kit This note describes the procedures to install an Mobile Upgrade kit to an existing Agilent 1220 Infinity II LC.

More information

Type overview. R B2 en-gb subject to changes 1

Type overview.   R B2 en-gb subject to changes 1 Technical data sheet R30..-..-..-B2 Characterised control valve, 6-way, Internal thread Two sequences (cooling/heating) with one 90 rotary actuator Switching or modulating control on the water side of

More information

Installation, Operation and Maintenance Manual for Back Pressure Regulator

Installation, Operation and Maintenance Manual for Back Pressure Regulator Installation, Operation and Maintenance Manual for Back Pressure Regulator Model 8860 2009 Groth Corporation IOM-8860 Rev. B 12541 Ref. ID: 95565 Page 2 of 13 Table of Contents I. INTRODUCTION 3 II. DESIGN

More information

1 & 3 Meter Tower CAT 1M 203R RIGHT MOUNT CAT 3M 203R CAT 1M 203L LEFT MOUNT CAT 3M 203L CAT 1M 203D DUAL MOUNT CAT 3M 203D

1 & 3 Meter Tower CAT 1M 203R RIGHT MOUNT CAT 3M 203R CAT 1M 203L LEFT MOUNT CAT 3M 203L CAT 1M 203D DUAL MOUNT CAT 3M 203D 1 & 3 Meter Tower CAT 1M 203R RIGHT MOUNT CAT 3M 203R CAT 1M 203L LEFT MOUNT CAT 3M 203L CAT 1M 203D DUAL MOUNT CAT 3M 203D CAT 1M 203H HEEL MOUNT CAT 3M 203H WARNING CAUTION: DIVING BOARD AND TOWER COMBINATIONS

More information

Global Lift ADA Compliance

Global Lift ADA Compliance February 9, 2012 Global Lift ADA Compliance All Global Lift Corp products comply with the ADA guidelines in 242.2 swimming pools and 242.4 spas 1009.2 pool lifts when installed following the specific Global

More information

How-To-Buy Guide for Bathtubs & Whirlpools

How-To-Buy Guide for Bathtubs & Whirlpools Bathrooms, they re what life s made of How-To-Buy Guide for Bathtubs & Whirlpools By Gray Uhl Brand Education Director American Standard BATHROOM FAUCETS HOW-TO-BUY GUIDE FOR BATHtubs and whirlpools 1

More information

Seated valves (PN 6) VL 2 2-way valve, flange VL 3 3-way valve, flange

Seated valves (PN 6) VL 2 2-way valve, flange VL 3 3-way valve, flange Data sheet Seated valves (PN 6) VL 2 2-way valve, flange VL 3 3-way valve, flange Description VL 2 VL 3 VL 2 and VL 3 valves provide a quality, cost effective solution for most water and chilled applications.

More information

SIZING OF WATER PIPING SYSTEM

SIZING OF WATER PIPING SYSTEM SIZING OF WATER PIPING SYSTEM (This appendix is informative and is not part of the code.) SECTION AP101 GENERAL AP101.1 Scope. AP101.1.1 This appendix outlines two procedures for sizing a water piping

More information

Department of Public Services Building Engineering Planning Water & Sewer POOL, HOT TUB & FENCE REQUIREMENT CHECKLIST

Department of Public Services Building Engineering Planning Water & Sewer POOL, HOT TUB & FENCE REQUIREMENT CHECKLIST Department of Public Services Building Engineering Planning Water & Sewer Address: Lot# POOL, HOT TUB & FENCE REQUIREMENT CHECKLIST 1. Complete Application a. Page 1, filled out accordingly b. Signed in

More information

-SWEPT AWAY- Description & Overview. VEX Classroom Competition Swept Away

-SWEPT AWAY- Description & Overview. VEX Classroom Competition Swept Away -SWEPT AWAY- Description & Overview Swept Away is a head-to-head robotics competition designed and scaled to be run in a classroom environment by a single teacher. This game provides a challenge for designers

More information

RESIDENTIAL SWIMMING POOL

RESIDENTIAL SWIMMING POOL MAIL PICK-UP A. SWIMMING POOL PERMIT TYPE ABOVE-GROUND POOL B. IDENTIFICATION PROJECT LOCATION (ADDRESS): NORTH WHITEHALL TOWNSHIP 3256 LEVANS ROAD, COPLAY, PA 18037 610-799-3411 610-799-9629 FAX www.northwhitehall.org

More information

MUELLER. A Wall Type. Indicator Post. Reliable Connections. General Information 2. Technical Data/ Dimensions 3. Installation 4-5.

MUELLER. A Wall Type. Indicator Post. Reliable Connections. General Information 2. Technical Data/ Dimensions 3. Installation 4-5. Installation Instructions manual MUELLER table of contents PAGE A-20814 Wall Type General Information 2 Technical Data/ Dimensions Installation 4-5 Maintenance 6 Parts 7 Indicator Post! WARNING: 1. Read

More information

SIGNATURE DEF REELS Models: Bare Reel Reel Reel Reel

SIGNATURE DEF REELS Models: Bare Reel Reel Reel Reel SERVICE BULLETIN SB2023 Rev C 7/11 SIGNATURE DEF REELS Models: 2400-006 Bare Reel 2400-007 16 Reel 2400-008 20 Reel 2400-009 30 Reel Thoroughly read and understand this manual before installing, operating

More information

HIP PRECAUTIONS INFORMATION

HIP PRECAUTIONS INFORMATION HIP PRECAUTIONS INFORMATION PAGE Hip Precautions Sitting Safely Following Precautions 1-2 Hip Safety: Sleeping Positions Safe Sleeping 3-4 Hip Safety: Getting Into and Out of Bed 5-6 Hip Safety Sitting

More information