Water Weir Flow Controller. Introduction. Safety Precautions. Mounting the Hardware
|
|
- Arthur Willis
- 5 years ago
- Views:
Transcription
1 Introduction Safety Precautions This instruction sheet describes how to set up and use the Hach (Figure 1). A water weir is a device that raises or diverts water to regulate the flow. Hach s water weir relies on gravity feed and head pressure to maintain a constant flow rate through the particle counting sensor. A constant flow rate allows a computer or particle counter to calculate the particle concentration. The vertical mounting position, relative to the water level in the filter, determines the head pressure. The particle sensor is mounted to the water weir so that the sensor plumbing connectors are lower than the water weir overflow drain. This allows the sensor to prime by gravity feed. Please read this instruction sheet before unpacking, setting up, or operating this instrument. To ensure your safety, use and install the only as specified in this instruction sheet. Figure 1 Mounting the Hardware Using Vertical Position to Set the Required Head The head pressure at the water weir inlet should be greater than four feet even when the water filter is at maximum head loss. If the maximum head loss of the filter is six feet, then adding the six feet of head loss to the required four-foot head yields 10 feet. Therefore, with six feet of head loss the water weir inlet would have to be positioned 10 feet below the water level in the filter. Thus the water weir will probably be positioned near the floor. (See Figure 2.)
2 , continued Four feet of head will maintain a sensor flow greater than or equal to 100 ml/min. Manually enter flow rates other than 100 ml/min. into the controlling computer to obtain correct particle concentration readings. Avoid tapping small diameter tubing, such as head-loss sensor tubing. Using small diameter tubing for the water weir input line can cause increased head loss and further lower the mounting height. In addition, bubbles may accumulate in the smaller line and prevent the water weir from priming after a filter backwash. If an optional strainer is used with the water weir, the strainer should be checked for clogging on a regular basis to minimize head loss. Selecting the Best Mounting Position After selecting the proper height for the water weir and sensor enclosure, determine the horizontal position of other components. Two factors influence the horizontal position: Length of sample tubing from tap Available wall space for each component The 2200 PCX ships with a 10-foot length of black, semi-rigid tubing that connects the sample tap and the water weir inlet. Do not lengthen this tubing. (Refer to Connecting the Plumbing for more information.) When selecting a tap location, make sure that the 10-foot sample tube will reach the particle counter and the water weir. Each particle counting component requires wall space for itself and the associated cables and plumbing connectors. Brackets and pre-drilled holes for mounting the water weir directly to the sensor s clips are provided for your convenience. Mount the water weir and sensor enclosure very close to each other. The water weir must be mounted vertically, but the sensor can be mounted in any position as long as the plumbing connectors on the sensor are lower than the water weir overflow. Mount the power supply enclosure above the flood level of the pipe gallery. If the six-foot long power supply-to-sensor cable is not long enough to elevate the power supply above flood level, use a longer cable (up to 25 feet, available only with a NEMA 4X enclosure). The required wall space and relative position of each component are shown in Figure 3. Page 2
3 , continued Figure 2 Determining the Required Head Maximum Head Loss plus 4 feet AC Power Adapter Power Counting Alarm Clean Sensor 2200 PCX Particle Counter Filter Sample Inlet tubing should not extend beyond 10 feet. Plumbing Tap with Shut Off Drain Page 3
4 , continued Figure 3 Mounting the PCX Plug-In AC Power Adapter 5.5 inches x 3.9 inches x 2.6 inches deep Note: Water Weir Flow Controller requires additional space mm 8.30 inches mm 7.00 inches mm 6.00 inches mm inches Power Counting Alarm Clean Sensor mm inches 2200 PCX Particle Counter 9.52 mm.375 inches 4 places Connecting the Plumbing Plumbing connections involve connecting the particle counter (large enclosure) and a flow controller to the water system. The most important part of connecting the plumbing is tapping the best sampling location in the water system. A good sampling location ensures a meaningful measurement. Use the guidelines below to tap the best location: The tap location must be able to supply more than 100 ml/min. flow with at least four feet of head. Tap upstream of a pressure reduction valve or a point where the plumbing becomes larger. These locations tend to create bubbles that can be erroneously counted as particles. Page 4
5 , continued Tap 18-inches downstream of a bend in the plumbing. Bends create turbulence, which mixes the particles, giving a better particle-size distribution. The 18 in. distance from the bend restores an even flow, making sure the mixing is complete, but not allowing enough time for the larger particles to settle. Tap a location that has a fast flow rate. This keeps the heavy particles suspended. Tap the pipe as shown in Figure 4 to avoid air or sediment contamination of the sample: Figure 4 Tapping the Best Sampling Location Air (Typical) Sediment (Typical) Poor Good Best Poor Connecting the Water Weir to the Tap 1. Install a separate plumbing tap, including a shut-off valve, for the water weir. Locate the best sample location as shown in Figure Attach the compression fitting to the plumbing tap. A white compression fitting for ¼ tubing is provided. Note: Do not remove the nut from the compression fitting. Removing the nut may result in small washers and ferrules falling out of the fitting and becoming lost. 3. Route the black, semi-rigid tubing to the water weir controller. Do not lengthen the tubing. Tubing lengths longer than 10 feet will cause the larger particles to drop out of the sample and distort the accuracy of particle-size readings. 4. Purge the sample tap and tubing of debris and sediment before connecting to the water weir. 5. Attach the remaining end of the ¼ tubing to the water weir as shown in Figure 5. Page 5
6 , continued Figure 5 Installing the Tubing in the Inlet Fitting Connecting the Water Weir to the Sensor 1. Cut another segment of black, semi-rigid tubing one inch longer than the length required to reach the inlet fitting on the bottom of the water weir. 2. Insert the tubing into the inlet fitting using the Quick Disconnect shown in Figure 6. Finger tighten the nut, then tighten until snug (no more than ¼ turn). 3. Attach the remaining end of the tubing to the water weir using a compression fitting. 4. Repeat steps 1 3 for the tubing that connects the sensor outlet fitting to the flow meter. Figure 6 Installing the Tubing in the Quick Disconnect Fitting Connecting the Water Weir Drain 1. Attach clear flexible tubing to connect the particle counter outlet (front side of sensor) and the water weir return. See Figure Install the drain on the water weir. Slide a clear, ½ in. I.D. hose over the barbed fitting on the water weir drain and route to the appropriate drain. 3. Open the shut-off valve on the plumbing tap and check for leaks. Page 6
7 , continued Adjusting the Flow Rate Initial Use of the Water Weir Adjust the flow rate to 100 ml/min. by changing the head. To decrease the head, move the white cap up; move it down to increase the head. See Figure 7. Nominal 100 ml/min. flow is typically achieved at 33 in. separation from the overflow port to the end of the sensor outlet line. Move the cap two or three inches to change the flow rate by approximately 1 ml/min. Measure the flow using a 100-mL graduated cylinder and a stopwatch. Purge the water weir and particle counter until any initial burst of sediment or debris is removed. This may take several minutes to several hours depending on the contamination and particle sizes being monitored. Particle counting may be performed during this cleanup period, but may be inaccurate due to this contamination. Figure 7 Water Weir and Particle Counter Configuration Sensor Sensor Outlet Flow Control Device (Water Weir) 2200 PCX Particle Counter To adjust the flow rate, slide this cap up or down mm (1 inch) = 1-2 ml/min To measure the flow rate, rotate the cap as shown and use a graduated cylinder and a stop watch. Measure for one minute mm (33 inches) from the overflow to the white cap is about 100-mL/minute. To Drain or Waste Page 7
8 , continued Technical Data The following table provides the head height for a specific flow rate. Table 1 Sensor Flow Table Sensor Model Head Height (inches) Flow Rate (ml/min.) PCX Hach Company, All rights reserved. Printed in the U.S.A. aa/dp 12/99 1ed
Blue River Technologies Port-A-Poly Mixer w/2.5 GPH LMI Pump And Secondary Water Dilution Line INSTALLATION AND OPERATION
Blue River Technologies Port-A-Poly Mixer w/2.5 GPH LMI Pump And Secondary Water Dilution Line INSTALLATION AND OPERATION Install your Blue River Technologies Port-A-Poly mixing system in a clean dry area.
More informationInstallation Operating Instructions for Simple Duplex Manual Manifolds PX-TSD Series
Introduction Powerex manifolds are cleaned, tested and prepared for the indicated gas service and are built in accordance with the Compressed Gas Association guidelines. The manifold consists of a regulator
More informationOPERATION MANUAL RTI RHS650 RTI TECHNOLOGIES, INC East Market Street York, PA Manual P/N
OPERATION MANUAL RTI RHS650 RTI TECHNOLOGIES, INC. 4075 East Market Street York, PA 17402 Manual P/N 035-80589-02 Table of Contents Components... 2 Test... 4 Recovery/Recycling... 5 Evacuation... 7 Charging...
More informationInstallation Operation Maintenance. Bermad Level Control Valve with Modulating Horizontal Float Pilot valve One Way Flow IOM.
Bermad Level Control Valve with Modulating Horizontal Float Pilot valve One Way Flow Model: FP 450-80 Installation Operation Maintenance PAGE 1 OF 5 1. Safety First BERMAD believes that the safety of personnel
More informationPRO SINK -R 1 and 2. Dilution system CONTENTS
PRO SINK -R 1 and 2 Dilution system CONTENTS 1.0 Product description 2 2.0 Warnings.. 3 3.0 Installation procedure 4 4.0 Plumbing connections 4 5.0 Technical features.. 5 6.0 Maintenance... 6 7.0 Troubleshooting......6
More informationIMPORTANT PLEASE READ BEFORE COMMENCING INSTALLATION
IMPORTANT PLEASE READ BEFORE COMMENCING INSTALLATION This Fitting Guide is designed to assist in the Installation of your Reverse Osmosis System. Some of the parts that are supplied with each system may
More informationFOR INSTALLING CO 2 BLENDER KIT (P/N IN BEER SYSTEM
IMI CORNELIUS INC One Cornelius Place Anoka, MN 55303-623 Telephone (800) 238-3600 Facsimile (612) 22-326 INSTALLATION INSTRUCTIONS FOR INSTALLING CO 2 BLENDER KIT (P/N 111612000 IN BEER SYSTEM SECONDARY
More informationAREA VALVE SERVICE UNITS
AREA VALVE SERVICE UNITS. Unit 8, McKenzie Industrial Park, Tel No.: 44 (0) 161 428 7200 Bird Hall Lane, Fax No.: 44 (0) 161 428 7010 Stockport, Email: info@p3-phoenix.com U.K., SK3 0SB www.p3-phoenix.com
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS HIGH PRESSURE PUMP To minimize vibration, it is best to build brackets on the motor itself, similar to alternator brackets. Use cardboard to construct a pattern first before making
More informationOperation Manual. Diaphragm Sensed Gas Pressure Regulators
687 Technology Way Napa, CA 94558 Phone: (707) 259-0102 FAX: (707) 259-0117 www.aptech-online.com Diaphragm Sensed Gas (AP/AZ/AK Models: 20, 100, 500, 1000, 1000T 10PA, 1100, 1200, 12PA, 1300, 1400T, 14PA,
More informationUltRo Dual Flow Reverse Osmosis Water System
UltRo Dual Flow Reverse Osmosis Water System Congratulations on this great investment to your health. **IMPORTANT NOTE BEFORE YOU BEGIN** We recommend you call your local friendly plumber to ensure proper
More informationSterisil Ac+ Installation & Operating Manual
Sterisil Ac+ Installation & Operating Manual 719 622 7200 Sterisil.com Arbor Dental Associates 2 Table of Contents Introduction 4 Sterisil Ac + Features 5 Installation Instructions 6 Maintenance 10 Troubleshooting
More informationRHPS Series RD(H)F40 User Manual. Read the complete manual before installing and using the regulator.
RHPS Series RD(H)F40 User Manual Read the complete manual before installing and using the regulator. 2 WARNING Before removing a regulator from the system for service, you must depressurize system purge
More informationINSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION
INSTALLATION INSTRUCTIONS CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION The CVS Controls 67CFR Filter regulator is a pressure reducing supply regulator typically used for pneumatic
More informationINSTALLATION INSTRUCTIONS FOR GRT75-PF-RFS PET FOUNTAIN
INSTALLATION INSTRUCTIONS FOR GRT75-PF-RFS PET FOUNTAIN Important: Read all instructions and refer to local codes prior to installation. l Local soil conditions may require more gravel for drainage. l
More informationACCESSORY KIT INSTALLATION INSTRUCTIONS
ACCESSORY KIT INSTALLATION INSTRUCTIONS 1NP0680 - PROPANE CONVERSION FOR USE WITH MODELS: PM8, PC8, PM9, PC9, FL9M, FL9C, FC9M, FC9C This conversion kit is to be installed by a qualified service agency
More informationInstallation Operating Instructions for Duplex Manual Manifolds PX-TMD Series
Introduction Powerex manifolds are cleaned, tested and prepared for the indicated gas service and are built in accordance with the Compressed Gas Association guidelines. The manifold consists of a regulator
More informationHyquest Solutions Pty Ltd
INSTRUCTION MANUAL BUBBLERS MODELS HS23SL / HS23DL / HS23DO QUALITY SYSTEM ISO: 9001 CERTIFIED HYQUEST SOLUTIONS PTY LTD PO BOX 332, LIVERPOOL B.C NSW 1871, AUSTRALIA Phone:(Int.) 612 9601 2022 Fax: :(Int.)
More informationCover Page for Lab Report Group Portion. Head Losses in Pipes
Cover Page for Lab Report Group Portion Head Losses in Pipes Prepared by Professor J. M. Cimbala, Penn State University Latest revision: 02 February 2012 Name 1: Name 2: Name 3: [Name 4: ] Date: Section
More informationSERVICE MANUAL SALAMANDER BROILERS RADIANT AND INFRARED 36RB 36IRB VULCAN C36RB C36IRB WOLF
SERVICE MANUAL SALAMANDER BROILERS RADIANT AND INFRARED VULCAN 36RB 36IRB WOLF C36RB C36IRB This Manual is prepared for the use of trained Vulcan Service Technicians and should not be used by those not
More informationInstalling a Probe. Typical Installation
for hazardous locations. Prior to any installation in a Classified Hazardous Location, verify installation methods by the Control Drawing referenced on the product s name tag 2. The Feed Through Assemblies
More informationAir Bubbler Depth Gauge DG2200 Installation and Reference Manual
Air Bubbler Depth Gauge DG2200 Installation and Reference Manual Rev. 3.2.2 06/2011 Installation and Reference Manual Page 2 Contents Chapter 1: Installation and Overview... 3 1.1 DG2200 Location Diagram...
More informationNeedle valve. Contents. User s Manual. (1) Be sure to read the following warranty clauses of our product 1. (2) General operating instructions 2
Serial No. H-V024-E-7 Needle valve User s Manual Contents (1) Be sure to read the following warranty clauses of our product 1 (2) General operating instructions 2 (3) General instructions for transportation,
More information36H SERIES Combination Gas Valve
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE. DESCRIPTION The 36H series combination gas valve is
More informationACCUMULATOR OPERATING & MAINTENANCE INSTRUCTIONS
ACCUMULATOR OPERATING & MAINTENANCE INSTRUCTIONS READ ALL INSTRUCTIONS PRIOR TO INSTALLATION AND OPERATION TO AVOID POSSIBLE INJURY Warning: Always consider any accumulator to contain pressure until proven
More informationTROUBLESHOOTING GUIDELINES
TROUBLESHOOTING GUIDELINES PROBLEM: Performance 1. The most common problem in this area comes from inadequate flow to the LAKOS Separator(s). All LAKOS Separators operate within a prescribed flow range
More informationINSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model 50 Systems Outfitted with ABM-725 Monitor C O M P A N Y
INSTALLATION and INSTRUCTION MANUAL for QUALITY AIR BREATHING SYSTEMS Model 50 Systems Outfitted with ABM-725 Monitor M A R T E C H S E R V I C E S C O M P A N Y OFFICE: (507) 843-4700 P.O. BOX 7079 Toll
More informationVessel Installation and Operating Manual
For In-ground and Aboveground Pools Vessel Installation and Operating Manual Important Safety Information Please read this manual prior to installation. Nature 2 Express is designed to sanitize in-ground
More informationTri-Tech Medical Inc.
Introduction Tri-Tech Medical manifolds are cleaned, tested and prepared for the indicated gas service and are built in accordance with the Compressed Gas Association guidelines. The manifold consists
More informationSingle and Triple Rain Barrel Setup
Single and Triple Rain Barrel Setup Introduction The following guide will enable you to prepare a rainwater collection system where there is an already established downspout. The construction is intended
More informationVAPOMATIC ANESTHETIC VAPORIZER
VAPOMATIC ANESTHETIC VAPORIZER INSTRUCTION MANUAL SOLD FOR VETERINARY USE ONLY BY: A.M. BICKFORD, INC. 12318 BIG TREE ROAD WALES CENTER, NY 14169 1-800-795-3062 Fax: 716-652-2046 www.ambickford.com sales@ambickford.com
More informationATD LB PRESSURE BLASTER INSTRUCTION MANUAL
ATD-8402 90LB PRESSURE BLASTER INSTRUCTION MANUAL SAVE THESE INSTRUCTIONS SAFETY INSTRUCTIONS FOR SANDBLASTER 1. Before opening the tank release the air pressure on the sand tank. To do this, turn off
More informationEngineering Excellence. Installation Guide
Engineering Excellence Installation Guide Two Handle Kitchen Faucet: 2DM200 2DM201 This product meets the following standards: ASME A112.18.1 ANSI A117.1 ANSI / NSF 61, SECTION 9 CUPC / IAPMO LISTED /
More informationHalsey Taylor Owners Manual 4410 Freeze Resistant Tubular Fountain STOP!
Halsey Taylor Owners Manual 4410 Freeze Resistant Tubular Fountain STOP! PLEASE READ THE FOLLOWING INFORMATION. ITALLATION ITRUCTIO FOR THE 4410FR FTN. WITH 97243C SINGLE VALVE CONTROL ASSEMBLY ARE LOCATED
More informationINSTALLATION and OPERATION INSTRUCTIONS
INSTALLATION and OPERATION INSTRUCTIONS FLOJET Beer Pump Panels MODEL NO. 66134-1 66134-2 66134-3 66134-4 IMPORTANT INFORMATION This manual has been prepared to assist you in the operation of Perlick Beer
More informationInstallation Instructions
Installation Instructions COLONY SOFT 7.0 Centerset Lavatory Faucet 7.0 with Speed Connect Drain Congratulations on purchasing your American Standard faucet with the Speed Connect drain, a features found
More informationExperiment 8: Minor Losses
Experiment 8: Minor Losses Purpose: To determine the loss factors for flow through a range of pipe fittings including bends, a contraction, an enlargement and a gate-valve. Introduction: Energy losses
More informationWW-720. Pressure Reducing Control Valve
WW-720 Pressure Reducing Control Valve (Size Ranges: 2-4 and 6-14 ) Installation Operation & Maintenance Page 1 of 6 1. DESCRIPTION The Model 720 Pressure Reducing is an automatic control valve (powered
More informationModel 420-HY Pressure Regulating Hydrant Valve
Model 420-HY Pressure Regulating Hydrant Valve INSTALLATION OPERATION MAINTENANCE 1. Safety First BERMAD believes that the safety of personnel working with and around our equipment is the most important
More informationBermad Model:
Bermad Model: 405-02 Manually Operated Hydraulic Valve INSTALLATION OPERATION MAINTENANCE Application Engineering BERMAD 1. Safety First BERMAD believes that the safety of personnel working with and around
More informationAir Operated Hydraulic Pumping Systems to 50,000 psi
High Pressure Equipment Air Operated Hydraulic Pumping Systems to 50,000 psi PS-10: 10,000 psi PS-20: 20,000 psi PS-30: 30,000 psi PS-40: 40,000 psi PS-50: 50,000 psi PS-90: 90,000 psi High Pressure air
More informationOperation Manual - PN A MENSOR MODEL 73 SHOP AIR BOOSTER
Operation Manual - PN 0017946001 A MENSOR MODEL 73 SHOP AIR BOOSTER Mensor Model 73 Shop Air Booster System (750 psi Version) April 23, 2012 Trademarks / Copyright Mensor is a registered trademark of Mensor
More informationInstallation, Operation and Maintenance Manual for Back Pressure Regulator
Installation, Operation and Maintenance Manual for Back Pressure Regulator Model 8860 2009 Groth Corporation IOM-8860 Rev. B 12541 Ref. ID: 95565 Page 2 of 13 Table of Contents I. INTRODUCTION 3 II. DESIGN
More informationINSTALLATION & START-UP INSTRUCTIONS. Clack WS1 & WS1.25 METER WATER SOFTENER SYSTEMS
INSTALLATION & START-UP INSTRUCTIONS Clack WS1 & WS1.25 METER WATER SOFTENER SYSTEMS 1999-2009 QualityWaterForLess.com - 1 - info@qualitywaterforless.com Preface: Thank you for your purchase of a new Water
More informationInstallation and Operating Manual
Safety Instructions Important Information Please read prior to installation ATTENTION! ELECTRICAL HAZARD FOR INGROUND POOLS AND ABOVEGROUND POOLS Installation and Operating Manual IMPORTANT Pool Owner,
More informationExercise 2-3. Flow Rate and Velocity EXERCISE OBJECTIVE C C C
Exercise 2-3 EXERCISE OBJECTIVE C C C To describe the operation of a flow control valve; To establish the relationship between flow rate and velocity; To operate meter-in, meter-out, and bypass flow control
More informationLAKOS Waterworks. PWC Series Sand Separators. Installation & Operation Manual LS-829 (10/12)
LAKOS Waterworks PWC Series Sand Separators Installation & Operation Manual LS-829 (10/12) Table of Contents Separator Operation... 3 Individual Model Details.... 4 Flow vs. Pressure Loss Chart 4 Installation
More informationAcornVac Vacuum Plumbing Systems - Trouble Shooting Guide
AcornVac Vacuum Plumbing Systems - Trouble Shooting Guide 1. Accumulators Problem Accumulator is overflowing If Accumulator continues to overflow Correction 1. Push and hold the manual activation button
More informationV8200A,C,H,M and VR8200A,C,H,M Continuous Pilot Combination Gas Controls
V800A,C,H,M and VR800A,C,H,M Continuous Pilot Combination Gas Controls APPLICATION These continuous pilot combination gas controls are used in gas-fired appliances up to 00 cfh capacity of natural gas.
More informationEasy Nest Kits. Installation Suggestions
Easy Nest Kits Installation Suggestions 2 General Recommendations Hydraulics Vacuum breakers should be installed to prevent siphoning. Flexible connectors should follow FRP tank manufacturers recommendations.
More informationFlashGARD HP Reverse Osmosis Filtration System Model Number FSTMO75 Part Number
3M Water Filtration Products FlashGARD HP Reverse Osmosis Filtration System Model Number FSTMO75 Part Number 56123-06 Installer: Please leave this manual with owner/operator. End User: Please retain for
More information14. Exploded View. Page 68
14. Exploded View Page 68 15. View of housing Page 69 11. Spare Parts HY05 HY13 55 E-2124010 Keys for safety, set=2pc. 54 E-2124012 Safety lock incl. 2 keys 1 B-3204031 1 B-2204101 1 B-2204111 1 2 B-2204105
More informationHalsey Taylor Owners Manual STOP!
Halsey Taylor Owners Manual 4710 Freeze Resistant Floor Mounted Steel Fountain STOP! PLEASE READ THE FOLLOWING INFORMATION. ITALLATION ITRUCTIO FOR THE 4710FR FTN. WITH 97243C SINGLE VALVE CONTROL ASSEMBLY
More informationTypes 749B and R130 Changeover Manifolds
Instruction Manual MCK-1179 Types 749B and R130 June 2012 Types 749B and R130 Changeover Manifolds TYPE HSRL-749B TYPE 64SR/122 TYPE R130/21 TYPE 749B/21 Figure 1. Changeover Manifolds and Regulator Assemblies
More informationWW-720. Pressure Reducing Control Valve
WW-720 Pressure Reducing Control Valve (Size Ranges: 2-4 and 6-14 ) Installation Operation & Maintenance Page 1 of 6 1. DESCRIPTION The Model 720 Pressure Reducing is an automatic control valve (powered
More informationOperating Instructions Model and Hydrostatic Test Pump
Operating Instructions Model 29200 and 2920 Hydrostatic Test Pump Dimension Weight Pump Pressure for 29200 Pump Pressure for 2920 Gauge for 29200 Gauge for 2920 Inlet Connection Outlet Connection Hose
More informationJacuzzi. J-CQ420 Cartridge Filter Installation and Operating Instructions
Jacuzzi J-CQ420 Cartridge Filter Installation and Operating Instructions IMPORTANT SAFETY PRECAUTIONS ATTENTION INSTALLER: This guide contains important information about the installation, operation and
More informationHGC-200 Hydro Gas Chlorinator
HGC-200 Hydro Gas Chlorinator ProMinent Fluid Controls Pty Ltd Head Office: Unit 4, 4 Narabang Way BELROSE NSW 2085 AUSTRALIA (PO Box 85, BELROSE WEST NSW 2085) Phone: (02) 9450 0995 Fax: (02) 9450 0996
More informationChemical Injection Technologies Installation/Service Bulletin
Bulletin 4002 Chemical Injection Technologies Installation/Service Bulletin SUPERIOR Series CL-16/26/56 Automatic Switchover Gas Chlorinator - Installation & Operation IMPORTANT!! READ THESE PRECAUTIONS
More informationRD(H)20/25 Pressure-Reducing Regulator User Manual
RD(H)20/25 Pressure-Reducing Regulator User Manual Read the complete manual before installing and using the regulator. 2 Safe Product Selection When selecting a product, the total system design must be
More informationBS Series Basket Strainer
BS Series Basket Strainer Operating, Installation, & Maintenance Manual Corrosion Resistant Fluid and Air Handling Systems. Dated 04-26-12 PRESSURE DROP SIMTECH strainers are engineered to offer the lowest
More informationInstallation Instructions
Installation Instructions S65-135 (Circular) S65-136 (Semi-Circular) Air Valve Retrofit For Non-Sectional Classic Washfountain Table of Contents.......................2-6 Metering Air Valve Parts List....................6
More informationicon i150 / i350 Installation / Operation Manual
i150 Concentrator i350 Concentrator icon i150 / i350 Installation / Operation Manual www.iconcentrator.com What You Will Need to Install Your icon In order to install your icon you will have to consider
More informationInstructions for Use
Select-380 T-Auto T-Auto Contents Page Instructions for Use Ref: 3.0 IFU 380 T-Auto Mar 18 2 Schematic layout of the doser 3 Quick-fit instructions 4 Description/Installation/Operation Pump tubes & Water
More information200 / 300 Upgrade Kits
NEXUS 210 / 310 UPGRADE KIT INSTALLATION 200 / 300 Upgrade Kits Installation and instruction manual for: Type 2 - Nexus 200 and 300 Upgrade Kit (Upgrades Nexus 200 and 300 Models Manufactured Between 2006-2009
More informationInstruction Manual MicroChem 2 Chlorine Probes Series CL4000
Instruction Manual MicroChem 2 Chlorine Probes Series CL4000-1 - 210.6405.15 These instructions describe the installation, operation and maintenance of the subject equipment. Failure to strictly follow
More informationOPERATING INSTRUCTIONS
OPERATING INSTRUCTIONS Tempe Pressure Cell June 1995 Fig. 1a 1400 Tempe Pressure Cells with 3cm cylinders and 6cm cylinders) mounted on the Tempe Cell Stand Fig. 1b Disassembled 1400 Tempe Pressure Cell
More informationModel VR6 System. Installation, Operation & Maintenance
Model VR6 System Installation, Operation & Maintenance General: All Archer Instruments chlorination systems are carefully designed and tested for years of safe, accurate field service. All Archer Instruments
More informationStandard Grout Header. Protected Pressure Gauge. High Pressure Gauge. In-Line Grout Header. Inline Protected Pressure Gauge
G A U G E S G R O U T H E A D E R S Protected Pressure Gauge In-line mounting accurately measures grout discharge pressure. Gauge is equipped with quick disconnect fittings that easily snaps into grout
More informationULTIMATE REVERSE OSMOSIS SYSTEM
ULTIMATE REVERSE OSMOSIS SYSTEM INSTALLATION INSTRUCTION & OWNER S MANUAL Ver 3.7 www.freedrinkingwater.com All Rights Reserved APEC Water Systems Please keep this Owner s Manual for future reference.
More informationInstallation Instructions
Installation Instructions COLONY SOFT 7.0 Single Control Lavatory Faucet with Speed Connect Drain Congratulations on purchasing your American Standard faucet with the Speed Connect drain, a feature found
More informationInstallation Guide & Owner s Manual. Model V4700. Water Filtration for Dental & Medical Instrument Washing Equipment
Installation Guide & Owner s Manual Model V4700 Water Filtration for Dental & Medical Instrument Washing Equipment Safety Guides & General Information Please read this manual completely before attempting
More informationCommercial Softeners. Installation, Operation & Maintenance Guide. Manual 002.1
Commercial Softeners Installation, Operation & Maintenance Guide Manual 002.1 Contents Page 1. Unpacking Instructions 3 2. Installation 3 Pre-installation checks Fitting the bottom distribution system
More informationWIDDER TOOLS. HPICAL Calibration Station 1 (203)
WIDDER TOOLS HPICAL-15000 Calibration Station WWW.WIDDERTOOLS.COM 1 1. TEST SET-UP a. Be sure air and water supply lines are installed per basic set-up & installation instructions supplied with calibration
More informationV48 Series 3-Way Pressure-Actuated Water-Regulating Valves With Union Fittings
Installation Instructions V48 Issue Date 08/30/01 V48 Series 3-Way Pressure-Actuated Water-Regulating Valves With Union Fittings Application IMPORTANT: The V48 Series 3-Way Pressure-Actuated Water-Regulating
More informationINSTALLATION, CARE & USE MANUAL. EMASMB & LMASMB Surface Mount Bottle Filling Stations
INSTALLATION, CARE & USE MANUAL EMASMB & LMASMB Surface Mount Bottle Filling Stations IMPORTANT THIS IS AN INDOOR APPLICATION ONLY! ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSONNEL. TOOLS/ITEMS
More informationCover Page for Lab Report Group Portion. Pump Performance
Cover Page for Lab Report Group Portion Pump Performance Prepared by Professor J. M. Cimbala, Penn State University Latest revision: 02 March 2012 Name 1: Name 2: Name 3: [Name 4: ] Date: Section number:
More informationINSTALLATION INSTRUCTIONS
EDGEMERE CENTERSET LAVATORY FAUCET INSTALLATION INSTRUCTIONS 708.0 Thank you for selecting American Standard... the benchmark of fine quality for over 00 years. To ensure that your installation proceeds
More informationSUMMITTM 400 & 600. Natural Gas Barbecues. Step-By-Step Guide
SUMMITTM 400 & 600 Natural Gas Barbecues Step-By-Step Guide W E B E R W E B E R W E B E R W E B E R Summit 400 NG Summit 600 NG CANADIAN GAS ASSOCIATION R A P P R O V E D WARNING: Follow all leak check
More information2. Determine how the mass transfer rate is affected by gas flow rate and liquid flow rate.
Goals for Gas Absorption Experiment: 1. Evaluate the performance of packed gas-liquid absorption tower. 2. Determine how the mass transfer rate is affected by gas flow rate and liquid flow rate. 3. Consider
More informationThe Discussion of this exercise covers the following points:
Exercise 3-2 Orifice Plates EXERCISE OBJECTIVE In this exercise, you will study how differential pressure flowmeters operate. You will describe the relationship between the flow rate and the pressure drop
More informationUsing the Akta Prime plus October 22, 2012
Some starting precautions: 1. Vacuum filter all buffers. Removes any large particles/debris that may clog your column De-gases the buffers 2. Clarify lysates first by centrifugation and then filtration
More informationInstallation and commissioning instructions 255 series and 256 series
Installation and commissioning instructions 255 series and 256 series Table of contents 1 General information... 3 1.1 About these instructions... 3 1.2 About this product... 3 1.3 Appropriate usage...
More informationABRASIVE SYSTEM ABRASIVE REGULATOR II 800# BULK ABRASIVE DELIVERY POT Abrasive Regulator II and 800# Pot Manual
ABRASIVE SYSTEM ABRASIVE REGULATOR II 800# BULK ABRASIVE DELIVERY POT TABLE OF CONTENTS Contact Information and Customer & Technical Service... 1 1 Introduction... 1 2 Abrasive Regulator... 1 Description:...
More informationHow Do I Install My Garden Master Bucket Garden?
How Do I Install My Garden Master Bucket Garden? 1. On the arrival of your Bucket Garden open the bucket and remove the 4 screws from the outside of the bucket rim and pull the 2 buckets apart. Check the
More informationP5513. Users Manual. Pneumatic Comparison Test Pump. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.
Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 TestEquipmentDepot.com P5513 Pneumatic Comparison Test Pump Users Manual PN 3963372 November 2010 2010 Fluke Corporation. All
More informationREVERSE OSMOSIS WATER FILTRATION SYSTEM MODEL EWR 4075 INSTRUCTION MANUAL
REVERSE OSMOSIS WATER FILTRATION SYSTEM MODEL EWR 4075 INSTRUCTION MANUAL Excalibur Water Systems 142 Commerce Park Drive, Unit M & N Barrie, Ontario L4N 8W8 CANADA www.excaliburwater.com 2013.05.7446
More informationVR8200A Continuous Pilot Combination Gas Controls
SUPER TRADELINE VR800A Continuous Pilot Combination Gas Controls Application These continuous pilot combination gas controls are used in gas-fired appliances that have up to 00 cfh capacity of natural
More informationInstalling ASI Umbilical Delivery Systems
Rev A 05 Nov 2015 Page 1 of 10 PURPOSE This guide provides an overview of tubing connections into an ASI wall-mounted Junction Box that has already been plumbed with a compressed air connection including
More informationV46 Series 2-Way Pressure-Actuated Water-Regulating Valves With Union Fittings
Installation Instructions V46 Issue Date 11//1 V46 Series -Way Pressure-Actuated Water-Regulating Valves With Union Fittings Application IMPORTANT: The V46 Series -Way Pressure-Actuated Water-Regulating
More informationInstallation and Instructions 2. Product Features 3-6. Key Pad Functions 7. Distributor Information Programming Guide 8. Master Programming Guide 9-14
Installation and Instructions 2 Product Features 3-6 Key Pad Functions 7 Distributor Information Programming Guide 8 Master Programming Guide 9-14 Dimensional Drawing 15 D-STC & D-SMM Valve Assembly 16-17
More informationSpecialists in HTM Medical Gas Pipeline Equipment AVSU/Module Operating and Maintenance Instructions
The Area Value Service Units and Module format (AVSU) provide a local gas isolation facility for use during normal installation and maintenance or in the event of an emergency. They are built in accordance
More informationEndo-Flush Order # ZUTR30004 OPERATION MANUAL. Zutron Medical, LLC W 98 th St #40-27 Lenexa, KS Phone Fax
OPERATION MANUAL Zutron Medical, LLC 17501 W 98 th St #40-27 Lenexa, KS 66219 Phone 877-343-5873 Fax 913-967-5944 ZUT-Lab-004-30004 REV. 03312017 Table of Contents 2 Introduction 1. Intended Use 2. Labels,
More informationSPECIFICATIONS CAPACITY
DMV-ZRD(LE)/6 SERIES Installation Instructions SPECIFICATIONS DMV-ZRD/6 DMV-ZRDLE/6 Two normally closed safety shutoff valves in one housing. V1 and V2 are fast opening, fast closing. Two stage and adjustable
More information4 IN. BALL LAUNCHER Engine Mounted / PTO Driven
4 IN. BALL LAUNCHER Engine Mounted / PTO Driven OPERATOR S PARTS and MAINTENANCE MANUAL 2006 EDITION BL-MAN-4EN Creation Revision date: 10MAR06 date: by: Ivon LeBlanc by: Table of Contents Table of Contents...
More informationInstallation Instructions for NP100 Series Nitrogen Control Panels
Installation Instructions for NP100 Series Nitrogen Control Panels Installation of the Nitrogen Control Panel involves installing the rough-in box and making the necessary piping connections in accordance
More informationOperating Manual. R280 Pressure regulator made of brass. 1. Intended Use
Pressure regulator made of brass Operating Manual 1. Intended Use Line or outlet pressure regulators- /reducer for Air, gases and liquids which is designed to effect reduction to a downstream pressure
More informationCentriFlow Meter Integrated Air Entrainment System
CentriFlow Meter Integrated Air Entrainment System INSTALLATION & OPERATION MANUAL January 2004 Revision 021-4 EASTERN INSTRUMENTS 416 LANDMARK DR. WILMINGTON, NC 28412 910-392-2490 Fax: 910-392-2123 website:
More informationHalsey Taylor Owners Manual
Halsey Taylor Owners Manual Wall Mount Steel Refrigerated Fountains INSTALLER These series fountains are among the easiest to install Fountains on the market today. To assure you install these models easily
More informationAppendix B Harris County Standard Operating Procedure for Determining In Situ Hydraulic Performance of High Flow Rate Bioretention Media
Objective Appendix B Harris County Standard Operating Procedure for Determining In Situ Hydraulic Performance of High Flow Rate Bioretention Media Provide as-built confirmation of proper installation and
More information