Test design for Tyco pressure relief valve
|
|
- Jemimah Lewis
- 6 years ago
- Views:
Transcription
1 Test design for Tyco pressure relief valve Design Team Ben Felix, Adrienne Jalbert, Ryan Lussier Josh Martin, Alicia Zollinger Design Advisor Prof. Mohammad Taslim Abstract Pressure relief valves with soft seals sometimes stick to the metal valve seat preventing the valve from opening at the correct pressure. This can cause serious damage to the system that the valve is supposed to be protecting. The design team assisted Tyco Flow Control in designing a test to identify the cause of sticking for the Electric Power Research Institute (EPRI). Specifically Crosby Series 800/900 valves were tested. Air was the working fluid. The variables tested include the amount of time the valve has remained closed, the material of the soft seat O-ring, the durometer of the O-ring, and the set pressure of the valve. Tests were performed at Tyco s ASME lab. Data was taken and statistical analysis was performed. In addition, the team did a set of independent tests to better establish how the soft seat design could be improved. To minimize sticking the team recommends using a high durometer (75 Shore A) O-ring with a circular crosssection which can be paired with an original valve opening device that reduces contact. Rod holds O-ring above metal seat O-ring soft seat Cap screws onto bottom of valve
2 The Need for Project Soft-seated valves often experience sticking that causes them to open at unacceptable pressures. Standards laid out by the American Society of Mechanical Engineers (ASME) require pressure relief valves (PRVs) to open within 3% of the set pressure (pressure at which PRVs are designed to open). The Electric Power Research Institute (EPRI) has noticed an industry wide issue within nuclear plants that valves are opening above this 3% specification. If a valve fails to open at the correct pressure, damage can be done to the system creating leaks or catastrophic failure. Because the valves under investigation are commonly used in nuclear power plants, leaks can involve hazardous materials and costly clean up. By determining the cause, steps can be made to prevent sticking and all of the consequences involved. Valve cross section illustrating O-ring soft seat (O-ring in red) The Design Project Objectives and Requirements The objective is to determine the Design Objective cause of sticking in valves and The objective of this project was to determine the cause of sticking use the results to make design in PRVs. This was done by studying the effect of the length of time recommendations to reduce the valve sits closed, the material of the soft-seat O-ring and the sticking. durometer of the soft-seat O-ring on sticking. From these results we were able to recommend the best O-ring to use in a Crosby 800/900 valve. Design Requirements The key requirement is that the redesigned PRV must conform to ASME codes. Most importantly, the valve must open within 3% of its set pressure. Also the valve must not leak and the working medium must be able to flow efficiently through the valve body, reaching full flow capacity by 10% above the set pressure.
3 Design Concepts Considered Testing was done on differing O- Changes in O-ring material, durometer, and cross section were all ring materials, durometers, and considered for their effectiveness in reducing the sticking in the valve. cross-sections. Additionally, the Viton is the current O-ring material used in the nuclear power team designed a fixture to hold industry. Ethylene Propylene Rubber (EPR) is another polymer that the valve open. provides an alternative to Viton that can also be used. EPR may be a better material to reduce the sticking force. Increasing the durometer of the O-ring material from 60 to 75 on the Shore A hardness scale will make the O-ring less apt to pinch or deform. Deformation leads to higher surface area between the seating surfaces, which may cause more sticking. While a higher durometer may reduce sticking, it is also less effective in preventing leakage. Currently, a circular O-ring cross-section is being used in the valve seat. With three O-ring shapes readily available for purchase we also considered square and quad O-ring cross-sections to reduce sticking. The square or quad cross-section may change valve seat geometry in a way that reduces sticking. Since they are not axisymmetric, alternate O-ring geometries may lead to poor performance due to poor Three O-ring cross sections installation. According to Tyco, sticking appears to mostly affect valves that have been sitting on a shelf with the full spring force pressing on the soft seat rather than the valves installed on a system. From this we concluded that the problem may be fixed by a fixture that holds the valve open during shipping and storage, eliminating O-ring contact. Recommended Design Concept In order to prevent sticking we Design Description recommend the use of a high Our recommended design concept consists of two phases: a durometer (75 Shore A) O-ring. recommended O-ring configuration and a fixture that will keep the To further reduce sticking we valve open when not installed on a system. recommend the use of a device The recommendations for O-ring configuration are a circular that prevents pressure on the O- cross section made of Viton with a durometer of 75 Shore A. These ring while the valve is being recommendations were made based on two sets of testing. The first stored. set of testing was performed at Tyco. It tested different O-ring materials, durometers, and valve set pressures. Originally twenty-four valves were to be tested but due to complications only eleven could be used. For independent testing, a fixture was designed and produced to
4 Independent test setup Independent test fixture mimicking Tyco valve seat mimic the valve seat to O-ring interactions and different O-ring cross sections were tested. In addition to this O-ring configuration we recommend the use of a valve opening device (VOD) that will hold the valve slightly open prior to its installation on the intended system. The VOD will be installed after the valve is fully manufactured and calibrated to its intended set pressure. The part consists of an opening rod which comes in direct contact with the disk of the valve, and a pipe cap which screws on to the nozzle of the valve and pushes the rod upward, opening the valve. Analytical Investigations A fractional regression analysis was performed on the results from the testing performed at Tyco. This found the factor most related to the sticking as well as how the factors interacted with each other. Finite element analysis was performed on our independent test fixture. This analysis showed that the pressure distribution was comparable to that of a PRV as well as establishing that the fixture would not fail under loading. A simple buckling analysis was done for the shaft of the opening VOD to confirm the structural integrity. Stainless steel was used for both the shaft and the pipe cap to match the material currently used in the valve. Experimental Investigations Testing was done at the Tyco facilities in Mansfield, MA to determine the leading factors in sticking of the soft seat to support our O-ring configuration recommendation and also to support the need for the valve opening design. The results showed that higher durometers of both Viton and EPR had a lower tendency to develop sticking forces. Regression analysis showed that durometer was the most significant factor. Of all the valves tested, those that sat for the longest period of time had the highest average sticking force. This inspired the idea of the VOD that keeps the valve open right up until it is installed on the system.
5 Pressure Relief Valve Compressed Air Source Digital Pressure Readout Outlet Drum Tyco Test Setup New O-ring Testing was also done to determine the best cross sectional shape of the O-ring to minimize sticking. These tests showed that the circular cross section currently in use was the best for this application as it showed the least average sticking force. Visual O-ring inspections showed visual wear and degradation in the form of surface irregularities. In Figure 5, the top image shows a new O-ring which shows consistent striations from left to right. The image on the bottom is a used O-ring with an irregular surface showing that there has been a physical change to the O-ring material as it sits in a valve over a nine month period. Used O-ring Comparison of new and used O-rings Key Advantages of Recommended Concept The greatest advantage to the VOD is that it requires no change to the current valve design. Also it uses standard parts with minimal manufacturing which results in low additional costs. The VOD has two configurations that are capable of fitting both the 800 and 900 series valves.
6 Financial Issues Money spent on independent testing was approximately $200. All other testing costs were financed by Tyco. The fixture to hold the valve open cost $ All testing done at the Tyco facility was financed by Tyco. The VOD prototype consists of two stainless steel parts, an end cap and a rod. These standard parts require minimal machining to meet their needs in the VOD. The cost of the end cap is $15.69 from MSC Industrial Supply and the steel rod cost $4.30 from McMaster- Carr. It would be feasible to cast this as one part if it were mass produced in order to reduce the cost. Recommended Improvements Future testing should include a For future testing done by Tyco, we recommend that our original full factorial analysis. Future test plan involving twenty-four valves is followed. This will allow the fixtures should be universal to all tester to draw conclusions about sticking with greater confidence than valves instead of specialized. the conclusions found using the fractional regression analysis. There is room for improvement with the VOD design. Future iterations could include a collar that would minimize the time involved in attaching the VOD to a valve to prepare it for shipping or removing the VOD to prepare a valve for installation. An adjustable design could also be implemented to make manufacturing and fitting the VOD to different valves a simpler process.
Bio-sample testing on an adaptation to a tensile testing machine
Bio-sample testing on an adaptation to a tensile testing machine Design Team Collin Creegan, Sarah Chamberland Kristine Murphy, Christine Sniezek Design Advisor Prof. Kai-Tak Wan Abstract The purpose of
More informationCOMMITTEE DRAFT. API 520 Part I 10 th Edition Ballot Item 2.1. This ballot covers the following item:
This ballot covers the following item: API 520 Part I 10 th Edition Ballot Item 2.1 2008 12 Modify guidance to PRV datasheets (Line 17) to assist user s with determining the temperature to use for selecting
More information776 Cryogenic Safety Valve
776 Cryogenic Safety Valve INTRODUCTION 776 Cryogenic Safety Valve The effects of exceeding safe pressure levels in an unprotected pressure vessel or system, can have catastrophic effects on both plant
More informationAtmospheric relief valve type 1100 Installation and maintenance instructions
SAPAG 1. Description Sapag atmospheric relief valves type 1100 have been selected for installation because of their performance features, reliability and ease of maintenance. They are designed to protect
More informationModel 1800 PFM Series Regulator. Technical Bulletin
Model 0 PFM Series Regulator Technical Bulletin Model 0 PFM Series Regulator 0 Elster American Meter The 0 PFM Series regulators are designed to control natural gas, air, nitrogen, carbon dioxide, propane
More informationFUNDAMENTALS OF PRESSURE RELIEF VALVES IN NATURAL GAS INSTALLATION - OPERATION - MAINTENANCE. Gary S. Beckett
FUNDAMENTALS OF PRESSURE RELIEF VALVES IN NATURAL GAS INSTALLATION - OPERATION - MAINTENANCE Gary S. Beckett Flow Safe Supply 10727 Tower Oaks Boulevard Houston, Texas 77070 What Are They and Why Are They
More informationLinear Compressor Discharge Manifold Design For High Thermal Efficiency
Purdue University Purdue e-pubs International Compressor Engineering Conference School of Mechanical Engineering 2016 Linear Compressor Discharge Manifold Design For High Thermal Efficiency Dietmar E.
More informationEASTERN ENERGY SERVICES PTE LTD. 60 Kaki Bukit Place #02-19 Eunos Tech Park Singapore, SG Singapore Telephone: Fax:
2 Table Of Contents 1. Introduction 3 2. About this Manual 3 3. Contacting YZ Systems 3 4. Vessel Components 4 5. Specifications 5 6. Application 6 7. Theory of Operation 7 8. DuraSite Installation & Use
More informationProduct Manual. Description. Specifications. CVS Type 1301F and CVS Type 1301G Regulator. Introduction
Product Manual CVS Type 1301F and CVS Type 1301G Regulator Introduction This CVS Controls product manual includes instructions for the installation, adjustment, maintenance and parts ordering of the CVS
More informationTHE BP-301 SERIES. Operating and Service Manual. Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv)
THE BP-301 SERIES Operating and Service Manual Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv) Issue B October 2015 1 TABLE OF CONTENTS 1. Description... 3 2. Installation... 3 3. Operation...
More informationWhat is pressure relief valve? Pressure relief valve
What is pressure relief valve? Pressure relief valve What is: Relief valve Safety valve Safety relief valve Type of pressure relief valve Pressure relief valve sizing base What are the sizing basis of
More informationCash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified
Cash Valve PILOT OPERATED BACK PRESSURE VALVE ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 01 Certified KP HIGH CAPACITY PILOT OPERATED BACK PRESSURE VALVE DESCRIPTION The Cash Valve Type KP is a pilot
More information6.6 Relief Devices. Introduction
6.6 Relief Devices Introduction Relief devices are used to help prevent a catastrophic failure of equipment and/or minimize the effects of any unanticipated or uncontrolled events. As such, relief devices
More informationModel PRS-07i. Stainless Steel Low Pressure, In-Line Pressure Regulator (Reducing Valve)
Phone (toll-free): (888) 380-9660 Phone (local): (973) 340-9955 Fax: (973) 340-9933 Web: www.straval.com 21 Columbus Avenue Garfield, NJ 07026 Model PRS-07i Stainless Steel Low Pressure, In-Line Pressure
More information1 SE/P-02. Experimental and Analytical Studies on Thermal-Hydraulic Performance of a Vacuum Vessel Pressure Suppression System in ITER
1 SE/P-2 Experimental and Analytical Studies on Thermal-Hydraulic Performance of a Vacuum Vessel Pressure Suppression System in ITER K. Takase 1), H. Akimoto 1) 1) Japan Atomic Energy Research Institute,
More informationFluid Sealing Association
Fluid Sealing Association STANDARD FSA-PSJ-701-06 PIPING SYSTEMS NON-METALLIC EXPANSION JOINT HYDROTESTING AND VACUUM TESTING 994 Old Eagle School Road, Suite 1019 Wayne, Pennsylvania 19087-1866 Phone:
More informationA New Piston Gauge to Improve the Definition of High Gas Pressure and to Facilitate the Gas to Oil Transition in a Pressure Calibration Chain
A New iston Gauge to Improve the Definition of High Gas ressure and to Facilitate the Gas to Oil Transition in a ressure Calibration Chain ierre Delajoud, Martin Girard DH Instruments, Inc. 4765 East Beautiful
More informationTHE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401
THE MF-400 SERIES Operating and Service Manual Series includes all variants of MF-400/401 Issue A October 2013 1 TABLE OF CONTENTS 1. Description... 3 2. Installation... 3 3. Operation... 4 4. Special
More informationSUPPLY OF ISOLATION AND APPLIANCE VALVES PTS - APPLIANCE BALL VALVE
PTS - APPLIANCE BALL VALVE 2 30.06.17 Issued for Tender AS ADE GS 1 12.04.17 Issued for Tender AS AD GS 0 06.03.17 Issued for Client s Comments AS AD GS Rev. Date Subject of revision Author Checked Approved
More information756 Safety Relief Valves
756 S a fe t y R e l i e f Va l ve s INTRODUCTION 756 Safety Relief Valves The effects of exceeding safe pressure levels in an unprotected pressure vessel or system, can have catastrophic effects on both
More informationCanNeed-DSST-100 Digital Secure Seal Tester --- To evaluate the secure seal quality of PET bottles, glass bottles and cans
CanNeed-DSST-100 Digital Secure Seal Tester --- To evaluate the secure seal quality of PET bottles, glass bottles and cans New piercing mode Traditional Piercing Mode The CanNeed -DSST-100 Digital Secure
More informationPOP Safety Valve. POP Safety Valve INTRODUCTION DEFINITIONS
POP Safety Valve POP Safety Valve INTRODUCTION The effects of exceeding safe pressure levels in an unprotected pressure vessel or system, can have catastrophic effects on both plant and personnel. Safety
More informationLeak testing of Valves. Standards for acceptable Rates of Valve Leakage
Leak testing of Valves Standards for acceptable Rates of Valve Leakage American Petroleum Institute (API) The API standard 598: Valve Inspection and Testing, covers the testing and inspection requirements
More informationSABERINDO PACIF SABERINDO PACIFIC CIFIC SABERINDO PA. A Tyco International Company
CIF A Tyco International Company 1 Foam Concentrate CIF 3% AFFF -UL Listed -UL Canada Listed 6% AFFF 6 parts AFFF concentrate to 94 parts water -UL Listed- Foam Liquid -UL Canada Listed 3% FLUOROPROTEIN
More informationDiscontinued. Powers Controls. Technical Instructions Document No P25 RV Rev. 1, May, RV 201 Pressure Reducing Valves.
Powers Controls RV 201 Pressure Reducing Valves Description Features Product Numbers Dual Pressure PRV Technical Instructions Document No. 155-049P25 RV 201-1 Single Pressure PRV The RV 201 Pressure Reducing
More informationBulletin /06/2012 Supersedes 10/23/00. Installation of John Crane Type 73 Inflatable Mechanical Seal. Page 01 of 10
01 of 10 1. Carefully read all instructions and notes before installation. 2. Bench Pre-assembly: a. Insert the support ring (item #1) inside the inflatable boot (item #2) to form inflatable seal assembly
More informationHermetic Compressor Manifold Analysis With the Use of the Finite Element Method
Purdue University Purdue e-pubs International Compressor Engineering Conference School of Mechanical Engineering 2008 Hermetic Compressor Manifold Analysis With the Use of the Finite Element Method Rinaldo
More informationPNEUMATIC PRESSURE CONTROLLERS
PNEUMATIC PRESSURE CONTROLLERS VARIABLE VOLUME PRESSURE CONTROLLER MODELS: V-1 R AND V-2R The 3D Variable Volume Pressure Controller is available for requirements of 0-1,000 psi and 0-6,000 psi in absolute
More informationKube Engineering Quinn E. Eddins, B.S.E.E Phone
Process Information: There are four ph assemblies used to monitor the ph value on a Sulfur Dioxide absorber. The chemical composition is approximately 20-30% Sodium Bisulfite, 4% Sodium Sulfite, and the
More informationNirvana Variable-Speed Drive, Contact-Cooled Rotary Screw Air Compressors
Variable-Speed Drive, Contact-Cooled Rotary Screw Air Compressors Exceptional Reliability Introducing - A True Variable-Speed Drive Compressor Now Available in Single- and Two-Stage. By matching a standard
More informationRS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.
RS(H)10,15 USER MANUAL Read the complete manual before installing and using the regulator. WARNING INCORRECT OR IMPROPER USE OF THIS PRODUCT CAN CAUSE SERIOUS PERSONAL INJURY AND PROPERTY DAMAGE. Due to
More informationDesign of an Automated Perfusion Pump James J Higham
Design of an Automated Perfusion Pump James J Higham Abstract Department of Gastroenterology Repatriation General Hospital The design and construction of an automated perfusion pump commenced as part of
More informationAmerican Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM
American Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM ASSE STANDARD #1003 - REVISED: 2009 Water Pressure Reducing Valves for Domestic Water Distribution Systems MANUFACTURER: CONTACT
More informationANDERSON GREENWOOD. Provides reliable overpressure protection in a cost effective package. Flow Control
ANDERSON GREENWOOD Provides reliable overpressure protection in a cost effective package. Product Overview Anderson Greenwood s LCP Series pilot operated safety valve is designed to provide the reliable
More informationSERIES 30. Spring Operated Tank Blanketing Valve PROTECTOSEAL.
SERIES 30 PROTECTOSEAL 1 2" NPT inlet and outlet standard Direct acting valve mechanism Optional flanged or threaded inlet and outlet connections available Inlet gas pressures from 10 PSIG to 200 PSIG
More informationProportional Relief Valves
www.swagelok.com Proportional Relief Valves R Series Liquid or gas service Set pressures from 10 to 6000 psig (0.68 to 413 bar) 1/4 and 1/2 in. and 6 to 12 mm end connections 2 Proportional Relief Valves
More informationOWNER S TECHNICAL MANUAL
EL SERIES OWNER S TECHNICAL MANUAL DP7002 1 Air Operated Diaphragm Pump Description The DP7002 1 air operated diaphragm pump is the ideal device for the pumping, transfer and dispensing of chemical liquids,
More informationInstallation Instructions
Installation Instructions S65-135 (Circular) S65-136 (Semi-Circular) Air Valve Retrofit For Non-Sectional Classic Washfountain Table of Contents.......................2-6 Metering Air Valve Parts List....................6
More informationTHE PROCESS OF JOINT INTEGRITY
BOLTED JOINTS A.333 THE PROCESS OF JOINT INTEGRITY To assist in managing a process, ask yourself the following questions: why, what, who, and how? Why do we need a Flange Joint Integrity program? This
More informationWarning: NEVER ALTER TEST EQUIPMENT
PAGE 1 OF 6 General: Pressure Testing Shop Built Tanks Pressure testing tanks with either positive pressure or vacuum can be a very dangerous exercise. It is important to understand the equipment involved
More informationCartridges for pressure relief functions Hard seated ND 16 to 32 for water and oil up to 350bar
Stainless Steel Cartridge valves according to DIN44 The valves are designed for use with water, water and oil emulsions, oil and gases. Their roust construction and compact design provide long life, ease
More informationThe flow direction must be observed during installation. It can be recognized by the following features: Flow direction. Gasket
6.2 Installation of the Safety Valve The correct installation within a plant is essential for the proper operation of a safety valve. Installation in this sense is e.g. - the choice of the gaskets - the
More informationFUNDAMENTALS OF PRESSURE REGULATORS ROBERT BENNETT MANAGER OF TRAINING ELSTER AMERICAN METER
FUNDAMENTALS OF PRESSURE REGULATORS ROBERT BENNETT MANAGER OF TRAINING ELSTER AMERICAN METER SUPPLY = DEMAND FUNCTION OF A REGULATOR A regulator may be defined as a "mechanism for controlling or governing
More informationGas Pressure Regulator HON 300
Gas Pressure Regulator HON 300 OPERATING AND MAINTENANCE INSTRUCTIONS/ SPARE PARTS Serving the Gas Industry Worldwide 300.20 EDITION 01/2017 1. General The "General description 300.00" for the gas pressure
More informationWastewater combination air valve in stainless steel AISI 316 Mod. SCS
Wastewater combination air valve in Mod. SCS The air valve guarantees the proper operation of sewage/industrial lines allowing the entrance of large quantity of air in case of pipe bursting or draining,
More informationErgonomic Handle for a 2DoF Robotic Hand Rehabilitation Device
Ergonomic Handle for a 2DoF Robotic Hand Rehabilitation Device Design Team Steven Adams, Kyle Hackmeister Lucas Johnson, Daniel Lau, Nicholas Pappas Design Advisor Prof. Constantinos Mavroidis Co-Advisors
More informationArt PRESSURE REDUCER
FUNCTION ICMA pressure reducers are devices that reduce and stabilize the incoming pressure from the water supply. Pressure reducers allow correct use on domestic systems, reducing malfunctions due to
More informationPRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.
PRS(TC)4,8 USER MANUAL Read the complete manual before installing and using the regulator. WARNING INCORRECT OR IMPROPER USE OF THIS PRODUCT CAN CAUSE SERIOUS PERSONAL INJURY AND PROPERTY DAMAGE. Due to
More informationPRO-50 Instrument Supply Regulator
Features CRN Approved The PRO-50 Regulator has been granted a Canadian Registration Number. Sour Service Capability Available in NACE configurations that comply with NACE MR0175/MR0103. Environmental limits
More informationProtecting your punching tool investment. Application-related problems and solutions
Protecting your punching tool investment Application-related problems and solutions Article reprinted with permission from the May 2000 issue of The FABRICATOR. By Nick Tarkany Economic shortcuts in the
More informationBy E. Smith - BP Amoco Exploration, Sunbury, England, and J. McAleese - City University, London, England
SET POINT TESTING An investigation of safety relief valve set point testing techniques By E. Smith - BP Amoco Exploration, Sunbury, England, and J. McAleese - City University, London, England Introduction
More informationDevelopment of a High Pressure, Oil Free, Rolling Piston Compressor
Purdue University Purdue e-pubs International Compressor Engineering Conference School of Mechanical Engineering 1994 Development of a High Pressure, Oil Free, Rolling Piston Compressor S. J. Delmotte
More information1805 Series Relief Valves
Instruction Manual Form 1211 1805 Series October 2011 1805 Series Relief Valves! WARNING Failure to follow these instructions or to properly install and maintain this equipment could result in an explosion
More informationMinimizing valve seat leakage
Minimizing valve seat leakage Dipl. Phys. Patrick Michel November 18, 2005 Abstract A mathematical model has been developed to simulate pressure relief valve seat leakage und conditions of angular and
More informationROTATING DISK VALVES INSTALLATION AND MAINTENANCE 1. SCOPE 3 2. INFORMATION ON USAGE 3 3. VALVE TYPES 3 4. OPERATORS 5 5. VALVE CONSTRUCTION 6
Sub Section INDEX Page Number 1. SCOPE 3 2. INFORMATION ON USAGE 3 3. VALVE TYPES 3 4. OPERATORS 5 5. VALVE CONSTRUCTION 6 6. INSTALLATION AND OPERATION 6 7. MAINTENANCE 8 8. REPAIR 9 9. ASSEMBLY 10 10.
More informationSecond Generation Bicycle Charging Station. Engineering Analysis
Second Generation Bicycle Charging Station By Jonathan Jerome, Michael Klinefelter, Connor Kroneberger, Kori Molever, and Robert Rosenberg Team 22B Engineering Analysis Document Submitted towards partial
More informationBACK PRESSURE / SUSTAINING
In many liquid piping systems, it is vital that line pressure is maintained within relatively narrow limits. This is the function of the 108 Pressure Relief / Back Pressure Series of the OCV control valves.
More informationRELIEF VALVES IN PARALLEL
RELIEF VALVES IN PARALLEL Mary Kay O'Connor Process Safety Center International Symposium BEYOND REGULATORY COMPLIANCE MAKING SAFETY SECOND NATURE October 26-28, 2010 James R. Lawrence Sr. Why use a Relief
More informationAcoustical Modeling of Reciprocating Compressors With Stepless Valve Unloaders
Acoustical Modeling of Reciprocating Compressors With Stepless Valve Unloaders Kelly Eberle, P.Eng. Principal Engineer keberle@betamachinery.com Brian C. Howes, M.Sc., P.Eng. Chief Engineer bhowes@betamachinery.com
More informationType R622 Pressure Reducing Regulator
Type R622 Pressure Reducing Regulator June 2010 Compact Design Protective Inlet Screen High Capacity Internal Relief Light Weight W8806 Inlet and Outlet Pressure Gauge Taps Figure 1. Type R622 Pressure
More informationDS05C,D,G Dial Set Pressure Regulating Valves
DS05C,D,G Dial Set Pressure Regulating Valves APPLICATION The Honeywell DS05C,D,G Dial Set Pressure Regulating Valve is a high quality pressure regulating valve that maintains a constant outlet pressure
More informationImpact of imperfect sealing on the flow measurement of natural gas by orifice plates
Impact of imperfect sealing on the flow measurement of natural gas by orifice plates Rubens Silva Telles 1, Kazuto Kawakita 2 1 IPT Instituto de Pesquisas Tecnológicas, São Paulo, Brazil, rtelles@ipt.br
More informationBACK PRESSURE / SUSTAINING
SPECIFICATIONS DIMENSIONS In many liquid piping systems, it is vital that line pressure is maintained within relatively narrow limits. This is the function of the 108 Pressure Relief / Back Pressure Series
More informationENGINEERING TECHNICAL REPORT
SSP DUOLOK FITTINGS ON 1.000 x 0.139 WALL 316SS TUBING ENGINEERING TECHNICAL REPORT SSP 8250 Boyle Parkway Twinsburg, Ohio 44087 U.S.A. mysspusa.com 1.330.425.4250 1 TABLE OF CONTENTS 1.0 Introduction
More informationLRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator.
LRS(H)4 USER MANUAL Read the complete manual before installing and using the regulator. WARNING INCORRECT OR IMPROPER USE OF THIS PRODUCT CAN CAUSE SERIOUS PERSONAL INJURY AND PROPERTY DAMAGE. Due to the
More informationFlanged pressure reducer/stabilizer VRCD
Flanged pressure reducer/stabilizer VRCD 2 This unit reduces and stabilizes the upstream pressure by operating on its load losses with a constant downstream pressure irrespective of the rate of flow value.
More informationEssa Certified Pressure Filters
PRODUCT BULLETIN Essa Certified Pressure Filters Introducing a new range of Essa Certified Pressure Filters FLSmidth is releasing a new line of plant and laboratory pressure filters. The Essa Certified
More informationA soft sealed atmospheric safety valve with large flow capacity and soft seat tightness for steam condenser and turbine applications
SAPAG A soft sealed atmospheric safety valve with large flow capacity and soft seat tightness for steam condenser and turbine applications Features The Sapag Series 1100 steam safety valve is used for
More informationBall valve HKSF-W100. Ball valve HKSF-W100. RMA Kehl GmbH & Co. KG Oststrasse 17 D Kehl / Germany
Ball valve HKSF-W100 RMA Kehl GmbH & Co. KG Oststrasse 17 D-77694 Kehl / Germany info@rma-kehl.de www.rma-armaturen.de 1 Design Features: RMA-ball valves type HKSF-W are fully welded and completely maintenance-free
More informationGREIG FILTERS, INC. OPERATION MANUAL
GREIG FILTERS, INC. OPERATION MANUAL MODEL DCFH 3P 15/3 100 S4 DOE/222 DUAL CARTRIDGE FILTER HOUSING TABLE OF CONTENTS I. INTRODUCTION II. CARTRIDGE FILTER HOUSING UNIT A. OPERATION B. INSTALLATION C.
More informationHigh Performance BSP Dial Up Pattern Pressure Reducing Valve
See our full range online at: www.vip-ltd.co.uk High Performance BSP Dial Up Pattern Pressure Reducing Valve VIP Product Code 31/0103 FUNCTION Pressure reducing valves are devices which, when installed
More informationANDERSON GREENWOOD SERIES 9000 POSRV INSTALLATION AND MAINTENANCE INSTRUCTIONS
Procedure-assembly-functional test and performance requirements 1 SCOPE 1.1 This document establishes the general procedure for assembly, functional testing and normal performance requirements of low Series
More informationPropor tional Re lief Valve s
www.swagelok.com Propor tional Re lief Valve s R Series Liquid or gas service Set pressures from 10 to 6000 psig (0.68 to 413 bar) 1/4 and 1/2 in. and 6 to 12 mm end connections Proportional Relief Valves
More informationNEW TYPE M PRESSURE RELIEF DEVICE
NEW TYPE M PRESSURE RELIEF DEVICE M PRESSURE RELIEF DEVICE ACCORDING TO EN 50216-5/A2 PATENTED 2 PRESSURE RELIEF DEVICE TYPE 50 M Section A-A 170 139 Transformer tank F 41.5 3 ø48.3 ø166 A P.R.D. TAG A
More informationE 158 E 198 E 248. Tank top mounting Connection up to G11 / 4 Nominal flow rate up to 250 l/min e d
R e t u r n - S u c t i o n F i l t e rs E 158 E 198 E 248 Tank top mounting Connection up to G11 / 4 Nominal flow rate up to 250 l/min 20.90-5e 0.0-2d D e s c r i p t i o n Application For operation in
More informationFUGITIVE EMISSIONS EXPERIMENTAL MEASUREMENTS AND EQUIVALENCY
FUGITIVE EMISSIONS EXPERIMENTAL MEASUREMENTS AND EQUIVALENCY ABSTRACT Jay Abrahimzadeh Joe Steinke Control Components Inc. Fugitive Emissions requirements, compliance, and use have gained momentum in the
More informationB L A C K H A L L. larner-johnsonvalve presentation
larner-johnsonvalve presentation History! The Larner-Johnson valve was originally designed and developed in 1920 s for use on hydraelectric power plants in the U.S.A., where it pioneered the application
More informationInstallation Operation Maintenance
682 Seal Cooler New generation seal cooler to meet and exceed the seal cooler requirements stated in the 4th Edition of API Standard 682 Installation Operation Maintenance Experience In Motion Description
More informationStructural Design of Tank Weighing Systems
Structural Design of Tank Weighing Systems 1. Initial observations Some essential rules must be followed when installing load cells in tanks. For example, tanks are frequently subject to weather conditions
More informationDESIGN OPTIMIZATION OF WORK ROLL CHOCK AND BACKUP ROLL CHOCK IN COLD ROLLING MILL
DESIGN OPTIMIZATION OF WORK ROLL CHOCK AND BACKUP ROLL CHOCK IN COLD ROLLING MILL Tukesh Sahu 1, Prof. G.R.Kesheory 2 1M.Tech Scholar, Department of Mechanical Engineering, VITS Indore, MP, India 2Assistant
More informationDesign Review Agenda
Design Review Agenda 1) Introduction, Motivation, and Previous Work a. Previous Work and Accomplishments i. Platform Launches ii. Successful Test Firings 2) More In-Depth Design Overview of the Existing
More informationBlue River Technologies Port-A-Poly Mixer w/2.5 GPH LMI Pump And Secondary Water Dilution Line INSTALLATION AND OPERATION
Blue River Technologies Port-A-Poly Mixer w/2.5 GPH LMI Pump And Secondary Water Dilution Line INSTALLATION AND OPERATION Install your Blue River Technologies Port-A-Poly mixing system in a clean dry area.
More informationHP/UHP Spring-Loaded Regulator
Description HP (High Purity) and UHP (Ultra High Purity) products are for service where the product must be kept free of contamination. The design is kept simple to minimise dead areas where contaminants
More informationAnderson Greenwood Type 4142 piped away pressure relief valves
7 Anderson Greenwood Type 4142 piped away pressure relief valves High capacity weight or spring loaded pressure relief valves that pipe away to a closed header system. Designed to work closer to a tank's
More informationPressure Dump Valve Service Kit for Series 2300 Units
Instruction Sheet Pressure Dump Valve Service Kit for Series 00 Units. Overview The Nordson pressure dump valve is used to relieve hydraulic pressure instantly in Series 00 applicator tanks when the unit
More informationCarter Pressure Fueling Nozzle Model 64201
Carter Pressure Fueling Nozzle Model 64201 Design Concepts Eaton s Carter product line is the leading supplier of nozzles qualified in accordance with SAE AS5877 (MIL-N-5877). Carter Model 64201H is listed
More informationTECHNICAL DATA. than the water inlet pressure to the concentrate
Foam102a 1. DESCRIPTION The Viking Low Flow Foam/Water proportioning system, is a UL Listed and FM Approved system, for use with 3M foam concentrates. This system consists of a standard wet pipe sprinkler
More informationSAPAG. Safety valves, type 5700 Storage, Use, Operation and Maintenance Instructions. IMPORTANT NOTICE
SAPAG IMPORTANT NOTICE Contents Important notice 1 0 Valve identification 2 1 Storage 2 2 Installation 2 3 Operation 2 4 Maintenance 3 4.1 Dismantling 3 4.2 Inspection 3 4.3 Repair 3 4.4 Assembly 4 4.5
More informationAmerican Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM
American Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM ASSE STANDARD #1048 - REVISED: 2009 Double Check Detector Fire Protection Backflow Prevention Assemblies Separate, complete laboratory
More informationPROCEDURES FOR REPAIRS TO ASME NV STAMPED PRESSURE RELIEF DEVICES OF NUCLEAR SAFETY RELATED PRESSURE RELIEF VALVES
NB16 0603 NR Task Group 1 9 16 1. One update by NR task group page 3: 7/17/19 2. Two updates to S6.1 and S6.3 on page 1: 7/19/17 SUPPLEMENT 6 PROCEDURES FOR REPAIRS TO ASME NV STAMPED PRESSURE RELIEF DEVICES
More informationMECHANICAL EQUIPMENTS: COMPRESSORS, PUMPS, SEALS, SPEED DRIVES, CONTROL VALVES & ACTUATORS & SAFETY RELIEF VALVES
Training Title MECHANICAL EQUIPMENTS: COMPRESSORS, PUMPS, SEALS, SPEED DRIVES, CONTROL VALVES & ACTUATORS & SAFETY RELIEF VALVES Training Duration 5 days Training Venue and Dates REF Mechanical Equipments:
More informationSV5 Safety Valve Installation and Maintenance Instructions
3120036/3 IM-S13-12 CH Issue 3 SV5 Safety Valve Installation and Maintenance Instructions 1. General specification 2. Supply 3. Before fitting the valve 4. Installation 5. Damage prevention 6. Commissioning
More informationFUNDAMENTAL PRINCIPLES OF SELF-OPERATED PRESSURE REDUCING REGULATORS. John R. Anderson Emerson Process Management Fluid Controls Institute
FUNDAMENTAL PRINCIPLES OF SELF-OPERATED PRESSURE REDUCING REGULATORS John R. Anderson Emerson Process Management Fluid Controls Institute For pressure control in process or utility applications, control
More informationSECTION BUTTERFLY VALVES
SECTION 15112 BUTTERFLY VALVES PART 1 GENERAL 1.01 SUMMARY A. All butterfly valves shall be of the tight closing, rubber seated type and fully comply with the latest revision of AWWA Standard C504, Class
More informationInstallation Instructions and valve Maintenance Rev. 0 of 21/09/15
ASSEMBLING PROCEDURE AND VALVE MAINTENANCE 1.0.... Safety Information 2.0.. INTRODUCTION 3.0 VARIATIONS 4.0..ASSEMBLING PROCEDURE FOR THE STEM 5.0 ASSEMBLING PROCEDURE FOR OUTLET CONNECTIONS 6.0 PROCEDURE
More informationDescription Advanced Features Typical Applications
Series single stage, brass barstock line regulator Description Advanced Features Typical Applications The Series regulators are intended for secondary pressure control of noncorrosive, high purity or liquefied
More informationPressure Reducing Valves Pressure Reducing with. Broady Flow Control. D Series Range. Pressure Reducing Valves. Broady Flow Control
Pressure Reducing Valves 00 Pressure Reducing with Broady Flow Control D Series Range Pressure Reducing Valves Broady Flow Control The Company Broady Flow Control is an Independent Valve Manufacturer,
More informationCrosby style JCE Safety Valve Installation, Maintenance and Adjustment Instructions CROSBY
CROSBY Table of contents 1. Installation 1 1.1. Drainage 1 1.2. Discharge pipework 1 1.3. Preparation for installation 1 2. Pressure adjustment 1 3. Maintenance 1 4. Dismantling 1 4.1. All valve types
More information1700ESL Kamvalok Coupler
PART #H32138PA November 2008 1700ESL Kamvalok Coupler OPW Transport Series Dry Disconnect Couplings are considered the standard of the industry. For use on multi-compartment petroleum, solvent and chemical
More informationSimplicity in VRU by using a Beam Gas Compressor
Simplicity in VRU by using a Beam Gas Compressor By Charlie D. McCoy and Mark Lancaster Abstract: Vapor Recovery Units are often expensive, complicated to operate and unable to deal with High H2S and liquids.
More information