Healthcare HTM and HBM Compliant Products
|
|
- Nicholas Oliver
- 5 years ago
- Views:
Transcription
1 HTM and HBM Compliant Products Optimal setup for a wall mounted automatic tap Aquarius automatic tap head Specially lengthened surgeons scrub-up taps* The problem of Acquired Infection is very high on the agenda of the Department of Health. There is increasing recognition of the problems and the areas where the most impact can be made and Hand Hygiene is top of the agenda. No-touch products have been identified by the NHS as offering significant benefit subject to the reliability of the specified products. Dart Valley Systems have achieved the level of reliability and value for money that no other company has matched. Many building guidelines (HBN s) recommend no-touch taps and WC Flushvalves. The HPA and DOH acknowledge that no-touch taps reduce the risk of cross contamination. DVS believe that the ease of use also encourages handwashing thus increasing compliance. Water Conservation Dart Valley Systems have hundreds of studies showing dramatic reductions achieved in water bills and with fast payback, demonstrating a good business case to invest in water saving products. As well as providing optimum water savings DVS provide scientifically proven solutions that can assist with reduction in biofilms. Electronic taps use the "optimum" amount of water as the taps only run when the hands are placed under the spout, limiting the water use to the precise time required and preventing taps being left running. Typical Savings with DVS Products Include: Clinical automatic no-touch taps: Up to 65% No-touch WC Flushvalve: Up to 30% Electronic urinal controls: Up to 80% Self-closing push taps: Up to 50% No-Touch Automatic Taps Hygiene Automatic taps are the most hygienic option available for hand washing. This is a very important aspect for all washrooms, but of increased importance for hospitals where cross-contamination needs to be avoided. Reliability DVS automatic taps have been extensively developed and tested to achieve the current high levels of reliability. Dean Hazell of James Paget Hospita commented,l "Dart Valley Systems automatic taps have been totally reliable and are good value for money. Whilst the main consideration is hygiene to avoid cross contamination, automatic taps also make significant savings on water". James Paget Hospital now have over 600 taps and have experienced outstanding performance from DVS taps. The hospital is also the most water efficient in their sector, medium acute outside London. Water Quality DVS designs offer optimum solutions to help maintain bacteria free water. Options available include automatic purging to avoid deadlegs and stagnent water, and thermal shock disinfection. Copper tails for taps can be provided if preferred to flexible connections. DVS have however carried out scientific evaluation at Plymouth University and recommend PEX lined hoses. More Information For more information on clinical automatic taps, urinal controls, WC flushing and self-closing push taps please see their respective sections in this catalogue. HTM and HBM Compliant Products 73
2 HTM and HBM Compliant Products Hands-Off Approach to Water savings and Associated Infections (HAI) are both Government and NHS Priorities. There are cost-effective solutions that can make significant contributions to improving hygiene and also reduce water consumption. Dorset County Hospital trialled DVS no-touch WC Flushvalves and no-touch taps. The water savings and the respose from the infection control team were very positive. The Trust concluded that it was a worthwhile investment to change all hand wash taps and all WC flushing devices throughout the hospital to no-touch. With the installation of no-touch clinical hand wash taps, the reduction in water costs will pay for the investments which will make an important contribution to reducing HAI. A major proportion of avoidable hospital-acquired infections are transferred to the patient via the hands of carers. The two most important aspects of improving hand hygiene are to increase the frequency and improve the effectiveness of hand washing. No-touch taps will help to achieve both of these objectives. Dr Peter Wilson, consultant microbiologist, University College Hospital, London, said: "Traditionally, elbow-operated taps have been used, but some dexterity is often needed to use them properly. Many still operate taps with fingers, risking spread of pathogens. An innovative solution is the use of infrared operated taps. No physical contact with the tap is then needed and recontamination is avoided. Provided they are reliable, these should reduce cross-infection, particularly in the intensive care unit. The Health Building Note (Number 57) recommends that these taps be installed in all intensive care units." James Paget NHS Trust is one of the hospitals that has recognised the benefits, and has now installed over 600 no-touch taps. The initiative has been keenly supported by the infectioncontrol team, and Linda Hawtin, clinical specialist - infection control, stated: "From an infection-control perspective, the taps are excellent because they reduce the risk of hand contamination after washing, and they are quick to use because the water is warm immediately, therefore encouraging staff to wash their hands more often." DVS no-touch surgeon taps (Ref: D606/SCRUB) at James Paget Hospital* Complies with HBN26 and HTM64. *Photos courtesy of James Paget. Recent trials in large hospitals showed a 65% reduction in the water used per hand wash with no-touch taps compared to leveroperated taps. The number of hand washes doubled, confirming the views that no-touch taps are so much easier to use and encourage hand-washing. Even for retro-fit, where the original taps have to be removed, payback on water savings alone can be as short as three years. There are other products that improve hygiene and save water, such as no-touch, wave-on, electronic WC flushing systems. These are hygienic, easy to operate (which helps the disabled and young children) and use 30% less water. Clients Dart Valley Systems has a strong NHS client base, including: Addenbrookes NHS Trust Birmingham Heartlands NHS Trust Blackpool Victoria Hospital NHS Trust Cornwall Trust Dorchester Hospital East Yorkshire Hospitals NHS Harefield Hospital Hereford Hospitals NHS Trust Invicta Community Care NHS Trust James Paget NHS Trust Northampton General Hospital Poole Hospital NHS Trust Tonvale Hospital Walgrave Hospital Westmorlands Hospital NHS West Dorset Hospitals NHS Trust Wrightington Hospital NHS Wycombe General Hospital 74 HTM and HBM Compliant Products
3 Surgeons Scrub-Up Troughs HTM 64 Compliant Surgeons Scrub-Up Troughs Features include: Hygienic and vandal resistant design Concealed pipework Constructed from 316 stainless steel Single, 2 or 3 station designs Specifically designed and developed for use with DVS surgeons scrub-up automatic taps HTM 64 compliant Pre-drilled holes for mounting taps (optional) D615/TR/1STN Single station surgeons scrub-up trough D615/TR/2STN 2 station surgeons scrub-up trough D615/TR/3STN 3 station surgeons scrub-up trough No-touch surgeons scrub-up automatic taps with DVS wash trough and Bushboard module No-touch surgeons scrub-up automatic taps with DVS 3 station scrub-up wash trough Surgeons Scrub-Up Troughs 75
4 PURGE CONTROLLER Clinical Automatic Taps The Aquarius range of taps are manufactured from stainless steel, and with a solid mm stainless steel ingot for the head assembly. Standard finish for these taps is brushed, but polished is available as an extra. Copper tails for taps can be provided if preferred to flexible connections. Aquarius WM Straight Tap With its modern and simple design, the Aquarius wall mount tap ensures the ultimate in hygiene for the most discerning of clients. Surgeons Scrub-Up D606/S WM straight - Brushed D606/SCRUB/S Surgeons scrub-up - Brushed The Surgeons scrub-up tap is based on the Aquarius WM tap but has additional features designed specifically for surgeons scrub-up areas. The tap has a longer reach and also incorporates the surgeons scrub-up chip providing longer sensing range and run-on time, meaning that surgeons can wash their hands and forearms easier and for longer. This tap is available in three lengths, 150mm, 200mm and 250mm. Aquarius High Neck The Aquarius High Neck offers a clinical deck mounted solution for hand wash or scrub-up. With its extra high body and long reach design the Aquarius High Neck makes it easier for surgeons and hospital staff to wash their hands and forearms. Its simple but unique design also makes it exceptionally easy to clean. Aquarius WM Filter Tap D670/HN High Neck - Brushed Twyford Bushboard D606/FLTR Aquarius WM with point-of-use filter - Brushed DVS have teamed up with specialists Twyford to help provide an easier all-round solution to purchasing complete washroom suites. The combination of Twyford Bushboard and DVS products ensure the client obtains optimum solutions from a single source, with technical specialist support for all of the products. For more information about DVS products incorporated with Twyford Bushboard ready plumbed modules, please contact DVS technical sales staff. Ready plumbed modules are ideal for retro-fit as well as new installations. Boxed out ready plumbed units such as that shown below are ideal for retro-fitting handwash stations. There may be certain high risk areas where point of use filters may be considered. DVS have specially designed this automatic tap to accept point-of-use filters. Disposable water filters for taps protect against Legionella and other bacteria in the water supply. The validated 0.2 µm filter membrane protects against Legionella spp, which are known contaminants of hospital water supplies and can lead to nosocomial infections. Filter features include: Quick connection Instant protection Validated 0.2 µm filter membrane Individually tested Pre-sterilised - Ready to use Cabling and plumbing for DVS automatic taps and WCs can be safely hidden away and easily accessed with ready plumbed modules 76 Clinical Automatic taps
5 Maintaining Good Water Quality Automatic Tap Purge Controller The automatic tap purge controller reduces maintenance and the risk of Legionella by purging the taps if they have not been operated for a predefined time. Purge run times are adjustable and delay can be set to detect non-use between 6 hours and 15 days. Purge can be set between 5 seconds and 5 minutes. A periodic purge can be switched on or off. D615/PURGE Automatic tap purge controller Features include: Simple to set up Saves manually running taps Readout monitors operations Easy to use Avoids stagnation Overcomes human error D615/PURGE/COUNTER Automatic tap purge controller with LCD counter PURGE CONTROLLER With Bushboard modules the purge controller can be situated out of sight and also easily accessed for timing adjustments if necessary. Hot Tap Surgical Purge (Thermal Shock) It is important to avoid touching taps during handwashing to avoid cross-contamination. It is also important to ensure the risk of bacteria in the water is controlled, particularly in areas with high risk patients. There are a number of ways to decontaminate water supplies, however the most common is to rely on having the hot water temperature at 60 c+ up to the thermostatic mixing valve. Some hospitals D615/THERMAL Hot tap surgical purge system have maintenance regimes where they raise this temperature periodically to a much higher temperature, such as 80 c once per month which reduces further the risk of bacteria build up in the hot water systems. Cold water systems require alternative measures to ensure limitation of bacterial growth. Wherever the thermostatic mixing valve is fitted the tap spout and outlet is an area of risk and requires consideration. There is significant awareness of legionella in hospitals but other waterborne bacteria such as pseudomonas auroginosa also need to be given serious consideration. There are common factors such as materials, water temperature and stagnation that affect the growth of many waterborne bacteria. Certain bacteria will proliferate in less favourable conditions, and some form of water treatment and maintenance should always be considered. Cold water supplies and tap outlets are sometimes neglected. DVS have devised a system that ensures all the components of the automatic tap system can easily be decontaminated using thermal shock treatment. The treated areas include the thermostatic mixing valve, solenoid valve, tap spout and tap outlet. This is a maintenance responsibility and a keyswitch is provided to ensure safe operation by a responsible person. The engineer (or an appointed person) should be present during the purging operation, however there is a red warning light that also confirms that hot water is being purged through the tap. Cabling and plumbing for the D615/THERMAL thermal shock system can be safely hidden away and easily accessed with ready plumbed modules. Maintaining Good Water Quality 77
6 Dimensions Not to scale HTM 64 Compliant Scrub-Up Troughs D615/TR/3STN Scrub-up trough - 3 station - Stainless steel D615/TR/2STN Scrub-up trough - 2 station - Stainless steel D615/TR/1STN Scrub-up trough - Single station - Stainless steel 78 Dimensions
7 Dimensions Not to scale Clinical Automatic Taps and Purge Controllers / / (HBN Preferred) Aquarius WM filter tap Fixing: 3/4" BSP (28mmø clearance drill hole) Aquarius WM Straight taps Fixing: 3/4" BSP (28mmø clearance drill hole) Surgeons scrub-up tap Fixing: 3/4" BSP (28mmø clearance drill hole) Note: With surgeons scrub taps the water runs for 20 seconds after use 500 D026/15/15 Pex hose WARNING HOT WATER THERMAL PURGING IN PROGRESS WHILST LIGHT IS FLASHING D670/HN Aquarius High Neck tap Fixing: 3/4" BSP (28mmø clearance drill hole) D615/PURGE Purge controller D615/PURGE/COUNTER Purge controller with LCD counter D615/THERMAL Hot tap surgical purge For more information on other automatic taps and accessories please refer to the automatic taps section on page 21. Hospital ensuite with DVS Flushvalve and Aquarius automatic tap. Dimensions 79
8 Price Guide Product Specific Sections For more information on other automatic taps and accessories please refer to the automatic taps section on page 20. For more information on safe ensuites please refer to the safe ensuites section on page 58. Automatic Tap Prices *For automatic tap prices please refer to the automatic tap price guide on page 30 where you will also find prices for accessories such as leads and power supplies. Important Clinical Automatic Taps Scrub taps have 20 seconds run-on time. For normal hand wash taps refer to pages Profile - Not to scale Code Description Price (RRP) DS D606/SCRUB/150 Surgeons scrub-up WM tap - Single station kit in S/Steel - 150mm length - Battery A D615/SCRUB/150 Surgeons scrub-up WM tap - Single station kit in S/Steel - 150mm length - Mains A D615/SCRUB/2STN/150 Surgeons scrub-up WM tap - 2 station kit in S/Steel - 150mm length - Mains A D615/SCRUB/3STN/150 Surgeons scrub-up WM tap - 3 station kit in S/Steel - 150mm length - Mains A D606/SCRUB/200 Surgeons scrub-up WM tap - Single station kit in S/Steel - 200mm length - Battery A D615/SCRUB/200 Surgeons scrub-up WM tap - Single station kit in S/Steel - 200mm length - Mains A D615/SCRUB/2STN/200 Surgeons scrub-up WM tap - 2 station kit in S/Steel - 200mm length - Mains A D615/SCRUB/3STN/200 Surgeons scrub-up WM tap - 3 station kit in S/Steel - 200mm length - Mains A D606/SCRUB Surgeons scrub-up WM tap - Single station kit in S/Steel - 250mm length - Battery A D615/SCRUB Surgeons scrub-up WM tap - Single station kit in S/Steel - 250mm length - Mains A D615/SCRUB/2STN Surgeons scrub-up WM tap - 2 station kit in S/Steel - 250mm length - Mains A D615/SCRUB/3STN Surgeons scrub-up WM tap - 3 station kit in S/Steel - 250mm length - Mains A D615/SCRUB/SPT/150 Surgeons scrub-up WM tap spout only in S/Steel - 150mm length A D615/SCRUB/SPT/200 Surgeons scrub-up WM tap spout only in S/Steel - 200mm length A D615/SCRUB/SPT Surgeons scrub-up WM tap spout only in S/Steel - 250mm length A Wall mounted. Standard finish is brushed stainless steel. Approx 200mm sensitivity range. D606/S/200/FLTR Aquarius WM filter tap - Single station kit - Battery (not Including filter or adaptor) A D615/FLTR Aquarius WM filter tap - Single station kit - Mains (not Including filter or adaptor) A D615/FLTR/2STN Aquarius WM filter tap - 2 station kit - Mains (not Including filters or adaptor) A D615/FLTR/3STN Aquarius WM filter tap - 3 station kit - Mains (not Including filters or adaptor) A D615/FLTR/SPT Aquarius WM filter tap spout only (not Including filter or adaptor)* A /POLISH Extra to have tap polished - Please add /POLISH to the end of your tap code A D615/PAL/FILTER PAL filter for use with Aquarius WM filter tap D D615/PAL/ADAPTOR Adaptor for PAL filters D Notes: Wall mounted. Standard finish is brushed stainless steel. Tap price does not include filter or adaptor. Note: above taps 230 o/a length. 280 o/a length for surgeons scrub also available Note: Standard taps have 2 second run-on time. Filter taps have 5 second run-on time For alternative Automatic Taps please refer to pages Profile - Not to scale Description Aquarius WM straight tap - all lengths available Notes: Wall mounted. Standard finish is brushed stainless steel. Polished finish available at an additional cost. Aquarius High Neck tap Notes: Deck mounted. Standard finish is brushed stainless steel. Polished finish available at an additional cost. Optional surgeons scrub-up chip for longer run-on time and further sensitivity range at an additional cost. 80 Price Guide
9 Price Guide Ready Plumbed Modules Profile - Not to scale Code Description Price (RRP) DS D615/TB/1400 Short unit with shelf, automatic tap and basin POA - D615/TB/2450 Full height unit with automatic tap and basin POA - Notes: Ready plumbed modules ideal for retro-fitting handwash stations. For special heights or hinged doors etc please contact our sales team for options. Also available with tap spout and wave-on sensors for warm and cold water. Purge Controllers Profile - Not to scale Code Description Price (RRP) DS D615/PURGE Automatic tap purge controller A D615/PURGE/COUNTER Automatic tap purge controller with LCD counter A D615/THERMAL/1STN Hot tap surgical purge system (thermal shock) - Single station A D615/THERMAL/2STN Hot tap surgical purge system (thermal shock) - 2 station A Notes: Includes parts to enable thermal purge of 2 taps using common TMV3 mixing valve. WARNING HOT WATER THERMAL PURGING IN PROGRESS WHILST LIGHT IS FLASHING D615/THERMAL/3STN Hot tap surgical purge system (thermal shock) - 3 station A D178/NC/3P 3 Port Valve - 6 Volt DC A Notes: Includes parts to enable thermal purge of 3 taps using common TMV3 mixing valve. The system includes the electrical control box, face plate, tap operation counter, keyswitch, solenoid valve and fittings. Automatic purge for avoiding stagnation when not in use and keyswitch thermal decontamination. HTM 64 Compliant Scrub-Up Troughs Profile - Not to scale Code Description Price (RRP) DS D615/TR/1STN Stainless steel scrub-up trough - Single station D D615/TR/2STN Stainless steel scrub-up trough - 2 station D D615/TR/3STN Stainless steel scrub-up trough - 3 station D D615/TR/SP Stainless steel scrub-up trough - Made to measure POA D Notes: Pre-drilled holes for taps are optional, please specify D615/TR/1STN/PP Extra cost to have scrub-up trough pre-plumbed - Single station (extra cost to above) A D615/TR/2STN/PP Extra cost to have scrub-up trough pre-plumbed - 2 station (extra cost to above) A D615/TR/3STN/PP Extra cost to have scrub-up trough pre-plumbed - 3 station (extra cost to above) A Notes: Pre-plumbed extra includes 4in1 TMV3 thermostatic mixing valve and 250mm long surgeons scrub-up tap kit/s. Price Guide 81
10 Patient Ensuites Low Risk Patient Ensuites Some Trusts may consider that low risk areas do not justify the substantial extra cost for the specialist unbreakable sanitary ware supplied by DVS. Twyford ceramic Sola Spectrum basins and Galerie WC Pans are therefore proposed for these areas. An alternative high security backplate specially designed for the Twyford Sola Spectrum basin is also part of the Low Risk ensuite. Otherwise the proposals are identical for the High Risk and Low Risk ensuites. In every other respect it is proposed that the High Risk and Low Risk safe ensuites are to the same specification. This means that the operation, technology, products and maintenance are standard throughout. Twyford Spectrum Backplate The Spectrum backplate has been designed specifically to match the Twyford Sola Spectrum clinical basin. One area of use is low risk MHU where the porcelain basin is considered acceptable but anti-ligature taps are required. The extra reach on this backplate has also been found to suit other applications where taps have to be removed and replaced with an anti-ligature solution. The design is also quite clinical and may be considered suitable for other areas where a no-touch wave-on solution for warm and cold water is required, such as patients ensuites. Patient Ensuites Sensor Options There are two options for operating the shower and WC Flushvalve. Both are vandal proof and virtually ligature free. D102/AV/B Anti-vandal wave-on sensor with 50mmø chrome bezel for WC Packages 5 and 6 show solutions for patient ensuites which are very similar to the safe ensuites but have an adjustable rail in the shower, shower handset and option of conventional water spout. The spectrum backplate however offers a neat solution. DVS have cooperated with a pod manufacturer to mould this into the pod wall. Most installations use the wave-on sensor but some prefer the push button tactile switch to reduce the risk of accidentally turning on the shower. D104/50/B Tactile switch with 50mmø s/steel bezel D800/WB/A/TWY Spectrum backplate (shown with Sola Spectrum ceramic basin) D606/S WM straight - Brushed Package 5 Includes: 9 D800/ENSUITE/LR5 Package 5 - Patient excl. shower Package 6 Includes: D800/ENSUITE/LR6 Package 6 - Patient incl. shower x Washroom control system 1 x TMV3 Thermostatic mixing valve 2 x Solenoid valves 1 x Aquarius WM spout 1 x Twyford Sola Spectrum ceramic basin 1 x WC Anti-vandal wave-on sensor 1 x WC Flushvalve 1 x Concealed cistern kit 1 x Twyford Galerie ceramic WC pan All of Package 5 plus: x Shower sensor for showerhead x Shower rail and handset x Additional TMV3 mixing valve x Additional solenoid valve Image outlines = Low Risk Twyford Sanitaryware 82 Patient Ensuites
11 Price Guide Patient Ensuite Package 5 - Patient (excl shower) Ref: D800/ENSUITE/LR5 Ensuite package 5 includes all of the individual items listed below except non-standard fixing lengths and optional extras. If longer fixing threads are required please specify. Fixing threads are available in 150mm, 200mm and 300mm. Image outlines = Low Risk Twyford Sanitaryware Ensuite Package 5 - Patient (excluding shower) Code Description Total (RRP) DS Breakdown DS D800/ENSUITE/LR5 Complete ensuite package 5 - Patient (excluding shower) - Standard A Notes: Includes standard Twyford fixing kits suitable for IPS panels. Excludes optional extras B Package Breakdown - Individual Items Code Description Price (RRP) DS TW/AVALONBTW Twyford Avalon ceramic WC pan (Includes fixings) B TW/AVALON/S Twyford Avalon - Seat and cover only B TW/SPECT500/1 Twyford Sola Spectrum 500 ceramic basin B TW/SPECT500/F Twyford Sola Spectrum 500 basin fixing kit B D600 Aquarius WM tap spout with no electronics A D107/AV/V2 Washroom control system kit - For when DVS high security backplates are not being used A D811/TALL/KIT/2 Concealed tall cistern kit A D214/TMV3/4/15 DVS thermostatic mixing valve (for basin) A Fixings and Extensions (Not included in the standard package) Code Description Price (RRP) DS D102/AV/EXT/150 Sensor thread extension for 100mm wall thickness (for WC sensor) A D102/AV/EXT/200 Sensor thread extension for 150mm wall thickness (for WC sensor) A D102/AV/EXT/300 Sensor thread extension for 250mm wall thickness (for WC sensor) A Notes: When ordering sensor extensions please specify for use with WC sensor. Optional Extras (Not included in the standard package) - Prices additional to package cost Code Description Price (RRP) Package Extra DS D800/M High security mirror with white moulded frame A D710/KEYSW Key switch for re-setting lock-outs A...continued on next page Patient Ensuites 83
12 Price Guide Patient Ensuite Package 6 - Patient (incl shower) Ref: D800/ENSUITE/LR6 Ensuite package 6 includes all of the individual items listed below except non-standard fixing lengths and optional extras. If longer fixing threads are required please specify. Fixing threads are available in 150mm, 200mm and 300mm. Please Note: Fixing extensions for shower sensor need to be specified below separately due to possible variations in wall thicknesses across installation locations. Image outlines = Low Risk Twyford Sanitaryware Ensuite Package 6 - Patient (including shower) Code Description Total (RRP) DS Breakdown DS D800/ENSUITE/LR6 Complete ensuite package 6 - Patient (including shower) - Standard A Notes: Includes standard Twyford fixing kits suitable for IPS panels. Excludes optional extras B Package Breakdown - Individual Items Code Description Price (RRP) DS TW/AVALONBTW Twyford Avalon ceramic WC pan (Includes fixings) B TW/AVALON/S Twyford Galerie - Seat and cover only B TW/SPECT500/1 Twyford Sola Spectrum 500 ceramic basin B TW/SPECT500/F Twyford Sola Spectrum 500 basin fixing kit B D600 Aquarius WM tap spout with no electronics A D107/AV/V2 Washroom control system kit - For when DVS high security backplates are not being used A D811/TALL/KIT/2 Concealed tall cistern kit A D214/TMV3/4/15/22 (X2) TMV3 thermostatic mixing valve x 2 (1 for basin and 1 for showerhead) A D173/SRH Showerhead with rail and handset A D102/SH/V2 Anti-vandal shower sensor for showerhead A D184 Solenoid valve for showerhead A Fixings and Extensions (Not included in the standard package) Code Description Price (RRP) DS D800/WB/EXT/150 Backplate fixing kit for 100mm wall thickness A D800/WB/EXT/200 Backplate fixing kit for 150mm wall thickness.00 A D800/WB/EXT/300 Backplate fixing kit for 250mm wall thickness A D102/AV/EXT/150 Sensor or showerhead thread extension for 100mm wall thickness A D102/AV/EXT/200 Sensor or showerhead thread extension for 150mm wall thickness A D102/AV/EXT/300 Sensor or showerhead thread extension for 250mm wall thickness A Notes: Please specify whether for use with WC sensor, shower sensor or showerhead. Optional Extras (Not included in the standard package) - Prices additional to package cost Code Description Price (RRP) Package Extra DS D173/AL/CM High security ceiling showerhead (instead of rail & handset) A D213/ADJ Showerhead temperature blending valve A D800/M High security mirror with white moulded frame A D710/KEYSW Key switch for re-setting lock-outs A 84 Price Guide
safe ensuites Tested at the HMP test centre
safe ensuites safe ensuites Designed for the toughest environments and manufactured using advanced technologies, safe-ensuite sanitaryware is robust yet designed to look domestic, making it ideal for therapeutic
More informationLigature Resistant Head
Ligature Resistant Head PRODUCT MANUAL IMPORTANT INSTALLER: This product manual is the property of the customer and must be retained with the product for maintenance and operational purposes. 1 Contents
More informationself closing tapware and bubblers AUTOMATIC SHUT-OFF REDUCE WATER WASTE IMPROVE HYGIENE VANDAL RESISTANT Spring Action Series Time Flow Series
self closing tapware and bubblers Spring Action Series AUTOMATIC SHUT-OFF REDUCE WATER WASTE IMPROVE HYGIENE VANDAL RESISTANT Time Flow Series A joint government and industry program When tested at, 2
More informationWater Temperature Control - Groups of Fixtures
Digital - Outlook ASSE 1070 Certified Up to six outlets from a single valve Programmable timed flow (independent for each outlet) On/Off or preset timed flow control with either touch or no touch sensors
More informationthe Professional Range of Baths An integrated range designed specifically to assist bathing in hospitals, care homes and at home
the Professional Range of Baths An integrated range designed specifically to assist bathing in hospitals, care homes and at home the Professional Range Integrated bathing systems by Gainsborough Baths
More informationTEMPERATURE STABILISED THERMOSTATIC SHOWER PANEL
Product Support Guarantee This product is guaranteed against faulty materials and workmanship for 12 months from date of purchase. For the guarantee to be valid, the unit must be installed by a competent
More informationHORNE T109A/306A/307A THERMOSTATIC SHOWER VALVE FOR SURFACE MOUNTING WITH TIMED FLOW CONTROL INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS
Horne Engineering Ltd PO Box 7, Rankine Street Johnstone, PA5 8BD Tel: +44 (0)1505 321455 Fax: +44 (0)1505 336287 Email: Technical@horne.co.uk Web: www.horne.co.uk HORNE T109A/306A/307A THERMOSTATI SHOWER
More informationHydraulic Valve. Installation guide. Please keep this booklet for future reference.
Hydraulic Valve Installation guide Please keep this booklet for future reference. Installer, when you have read these instructions please ensure you leave them with the user. HYD_B-01 1. Introduction The
More informationHydraulic Valve Installation Guide
Hydraulic Valve Installation Guide 1. Introduction The Hydraulic Valve is an automatic urinal flush control valve. The valve uses a unique and simple mechanism which prevents water waste by ensuring that
More informationIntroduction. Legal Duties. Risk Assessment
All Hampstead Hill School Policies are always to be read and considered in conjunction with Equal Opportunities, Race Equality and Inclusion Policies. This Policy of Hampstead Hill School applies to all
More informationSpecialists in HTM Medical Gas Pipeline Equipment AVSU/Module Operating and Maintenance Instructions
The Area Value Service Units and Module format (AVSU) provide a local gas isolation facility for use during normal installation and maintenance or in the event of an emergency. They are built in accordance
More informationURINAL FLUSHING SYSTEM WITH MICROWAVE SENSOR
URINAL FLUSHING SYSTEM WITH MICROWAVE SENSOR Installation & Maintenance Instructions EMF303M I00013_Aug 15 Call 1300 369 273 www.enware.com Enware Australia Pty Limited 9 Endeavour Rd Caringbah NSW 2229
More informationGemini Assisted Bath Product Care & User Operating Instructions
Gemini Assisted Bath Product Care & User Operating nstructions Technical Product Specification Minimum rim height Lift range (combined) Fill volume Time to fill Total weight (including 80kg patient) Electric/hydraulic
More informationbathrooms.com Concentric Thermostatic Shower Mixers Cleaning and Care Installation Manual Contents
bathrooms.com Concentric Thermostatic Shower Mixers Contents Page 3 - General Information & Safety Page 4 - Installation Page 5 - Concentric Valve Set-up Page 6 - Exposed fitting of Concentric Mixer Valves
More informationInfrared Linescanners
Thermal Imaging and Temperature Profiles for Continuous Process Monitoring and Quality Control HD Infrared Linescanners PROCESS & ANALYTICAL INSTRUMENTS Mountings and Accessories LSPHD Mountings and Accessories
More informationDB 61 Dolphin TMV3 Integrated Thermostatic Mixing Valve
INSTALLATION AND MAINTENANCE GUIDE DB 61 Dolphin TMV3 Integrated Thermostatic Mixing Valve Saving water, saving power, promoting hygiene Important: Read carefully before installing product DOLPHIN Revision
More informationBASIN AND WALL MIXER INSTALLATION INSTRUCTIONS
BASIN AND WALL MIXER INSTALLATION INSTRUCTIONS IMPORTANT INFORMATION IMPORTANT All tapware and showers to be installed by a licensed plumber and to Australian Standards. Fit tempering and pressure reduction
More informationLocator Locator-D-Lux Air-Saver G1 Air-Saver G2
170663_air_saving_products 17-02-2011 16:42 Pagina 1 Locator Locator-D-Lux Air-Saver G1 Air-Saver G2 AIR SAVING PRODUCTS 170663_air_saving_products 17-02-2011 16:42 Pagina 2 170663_air_saving_products
More informationPneumatic spool valve islands
Pneumatic spool valve islands P7.GB.R MEGA SPOOL VALVE ISLANDS MEGA pneumatic spool valve islands offer maximum performance along with flexibility, easy installation and simple operation. Due to their
More informationSECTION SHOWER AND BATH ENCLOSURES. Display hidden notes to specifier by using Tools / Options / View / Hidden Text.
SECTION 10185 SHOWER AND BATH ENCLOSURES Display hidden notes to specifier by using Tools / Options / View / Hidden Text. PART 1 GENERAL 1.1 SECTION INCLUDES A. Bathtub wall enclosures. B. Shower wall
More informationTB 42. Low maintenance effort saves on time and costs. High variability for vehicle types, construction and expan- sion options
TB 42 TB 42 commercial vehicle wash for automatic exterior cleaning. The 3-brush gantry allows a washing height of 4.25 m and offers total flexibility for different vehicle sizes and types. 1 Low maintenance
More informationInstallation and Use Manual
Installation and Use Manual EMASMB & LMASMB Surface Mount Bottle Filling Stations Model EMASMB IMPORTANT THIS IS AN INDOOR APPLICATION ONLY! ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSONNEL.
More informationRecommended Retail Price List
Hansgrohe P ty Ltd 1/ 123 Cam berwell Rd East Hawthorn 3123 Australia Tel: 03 9811 9971 P a g e 1 Recommended Retail Price List Effective December 2017 Hansgrohe P ty Ltd 1/ 123 Cam berwell Rd East Hawthorn
More informationMEDIANA HEARTON AED A15. Mediana Automated External Defibrillator A15
AED A5 Mediana Automated External Defibrillator A5 AED A5 COVER Protected icon sheet, shock button, adult/paediatric mode switch. 7 BATTERY Disposable LiMnO2 Non-Rechargeable. 2yrs shelf life, 5yrs standby
More informationthe Professional Range of Baths
the Professional Range of Baths An integrated range designed specifically to assist bathing in hospitals, care homes and at home the Professional Range Bathing systems by Gainsborough Specialist Bathing
More informationTwin & Triple Control Concealed Thermostatic Shower Valve
Twin & Triple Control Concealed Thermostatic Shower Valve Installation & Operating Guide Please leave this installation & user guide with the end user CONTENTS: 1. Introduction & Safety 1 2. Dimensions
More informationLegionella Guidance. Property managers specialising in residential, apartment, block and estate management
Legionella Guidance Legionnaires disease is a potentially fatal lung infection - pneumonia, that is caused by the legionella bacteria. It can be caught by breathing in small droplets of contaminated water.
More informationIssue date: July 2012 Issue 1
Guide to commissioning, in-service inspection, in-service test and frequency of testing Thermostatic Mixing Valves (TMV) for use in health and social care establishments as Type 3 valves (TMV3 approved).
More informationAREA VALVE SERVICE UNITS
AREA VALVE SERVICE UNITS. Unit 8, McKenzie Industrial Park, Tel No.: 44 (0) 161 428 7200 Bird Hall Lane, Fax No.: 44 (0) 161 428 7010 Stockport, Email: info@p3-phoenix.com U.K., SK3 0SB www.p3-phoenix.com
More informationOWNER S GUIDE DUAL CONTROL THERMOSTATIC SHOWER VALVE. Shower Control. may differ depending on choice of Model. Concealing Plate. Handles and ISSUE 01
DUAL CONTROL THERMOSTATIC SHOWER VALVE Shower Control Handles and Concealing Plate may differ depending on choice of Model OWNER S GUIDE ISSUE 01 These instructions cover all exposed or concealed versions
More informationPlasma Cleaner. Yamato Scientific America. Contents. Innovating Science for Over 125 Years. Gas Plasma Dry Cleaner PDC200/210/510 PDC610G.
Yamato Scientific America Innovating Science for Over 125 Years Plasma Cleaner Contents Gas Plasma Dry Cleaner PDC200/210/510 PDC610G Gas Plasma Reactor 145 146 147 149 144 Gas Plasma Dry Cleaner Plasma
More informationThe CompacSas BAH airlock is the ideal solution for transforming an existing door into an airlock
CompacSas BAH Improved filtering for existing accesses Manual Attack Resistance Ballistic Resistance Access Flow Recyclable product Energy savings Models: CompacSas BAH IMPROVED FILTERING The CompacSas
More informationInstallation Guide - C01202 & C01203 Thermostatic Mixing Valve TMV2
The following information is required for use when the Saracen range of thermostatic mixing valves is used in a TMV2 Applications under the requirements of BS EN 1111: 1999 Sanitary tap ware Thermostatic
More informationMiniMag. 1 of 8. The MiniMag scrubber s 2 recover drain are 80% larger than a 1.5, making the MiniMag scrubber s drain hose less likely to clog.
MiniMag Scrubber tank doesn t bolt to the frame, and so is less likely to be damaged or risk to stripped out inserts. The heavy duty and thick walled poly tank, pivots on smooth bosses. The MiniMag scrubber
More informationShandon Cryotome Cryostat Series
Shandon Cryotome Cryostat Series Shandon Cryotome FSE Shandon Cryotome FE Shandon Cryotome SME Analyze Detect Measure Control Shandon Cryotome Cryocassettes Cryocassettes for the Shandon Cryotome FSE /
More informationVegas Easyfit Kitchen Sink Mixer
Vegas Easyfit Kitchen Sink Mixer Installation Instructions & User Guide Please keep these instructions for future reference Contents Thank you for choosing Bristan, the UK s leading taps and showers expert.
More informationAIR-SAVER G1 AIR-SAVER G2 LOCATOR LOCATOR-EV COMPRESSED AIR CONDENSATE MANAGEMENT AND ENERGY SAVING PRODUCTS AIR SAVING PRODUCTS
AIR-SAVER G1 AIR-SAVER G2 LOCATOR LOCATOR-EV ENVIRONMENT ADDING VALUE SAFEGUARD RELIABLE COMPRESSED AIR CONDENSATE MANAGEMENT AND ENERGY SAVING PRODUCTS AIR SAVING PRODUCTS AIR SAVING PRODUCTS INDEX Chapter
More informationANZAI AZ-733VI. Respiratory Gating System. since 1976
ANZAI since 1976 Respiratory Gating System AZ-733VI Specifications AZ-733VI Dimension Configuration Options Sensor Port W:260 D:230 H:126mm Sensor Port Laser Sensor & Fixing Arm Relay Box Wave Monitor
More informationFIRE PROTECTION PRODUCTS
AGF Manufacturing Inc. FIRE PROTECTION PRODUCTS PRODUCT CATALOG CAT-AGF_V002 1/15 Reliability, Versatility, Code Compatibility AGF Product Catalog Table of Contents COLLECTa ndrain Auxiliary Drains Model
More informationPEDESTAL MOUNTED EMERGENCY EYE & EYE/FACE WASH
PEDESTAL MOUNTED EMERGENCY EYE & EYE/FACE WASH Installation, Operating & Maintenance Instructions EEE180 EEE210 EFE360 EFE390 ENBE180 ENBE210 ENBE360 ENBE390 I00011_Apr 18 NOTE: THIS DOCUMENT IS TO BE
More informationPremium Series. Economical Price & Reliable Performance. High Quality. Rust-Resistant. Long Life. Tamper-Resistant locking Screw.
Premium Series High Quality Forged Brass Body Rust-Resistant Nickel Plated Finish Long Life Corrosion Resistant Valve Seat Economical Price & Reliable Performance Tamper-Resistant locking Screw Reduces
More informationMEDUMAT Standard a MEDUMAT Standard. The Ventilation Standard for Professionals
a The Ventilation Standard for Professionals a The Ventilation Standard for Professionals a offers you everything you need for reliable emergency ventilation. Users around the world are impressed by its
More informationPhuel Modular Control Units
Phuel Modular Phuel Modular, like our market leading Modular BOPs, provide an efficient flexible solution to suit any customer s needs. Each unit is constructed from the best of materials and supportable,
More informationIHEA HFMC Stuart Lloyd. Managing Legionella: Achieving Best Practice. Legionella background
Stuart Lloyd worked in the industry since 1986 worked for 7 years with the water treatment arm of a Maintenance Contractor undertaking Legionella Risk Assessments including costing of any associated remedial
More informationControl of Legionella Policy. July 2017 ORCHARD ACADEMY TRUST. Control of Legionella Policy -Page 1
Control of Legionella Policy July 2017 Control of Legionella Policy -Page 1 ORCHARD ACADEMY TRUST Control of Legionella Policy This policy sets out the control of legionella in hot and cold water systems
More informationAbout. providing superior performance and reliability. Bromic regulators are AGA or UL144 approved.
REGULATORS 1 About Bromic Plumbing & Gas provide a wide variety of regulators to suit applications from recreational to professional, in both Natural Gas & LPG (propane). Our range of regulators includes
More informationApricot Kitchen Sink Tap
Apricot Kitchen Sink Tap Installation Instructions & User Guide Please keep these instructions for future reference and request of replacement parts Contents Thank you for choosing Bristan, the UK s leading
More informationCOMPRESSED AIR SAVING PRODUCTS INDEX. Useful information AIR-SAVER G1 AIR-SAVER G2 LOCATOR. Condensate Management Specialist
INDEX Useful information AIR-SAVER G1 AIR-SAVER G2 LOCATOR COMPRESSED AIR SAVING PRODUCTS Condensate Management Specialist Information provided herewith is believed to be accurate and reliable. However,
More informationOperation manual Level sensor DC-LS-50 Operation Manual Level Sensor DC-LS-50
Operation Manual Level Sensor DC-LS-50 Rev.02 (2014.06) OL Page 1 of 8 Table of contents I. STRUCTURE OF THE MANUAL / CLARIFICATION... 3 II. SAFETY AND HEALTH CONCERNS... 4 1 INTRODUCTION... 5 1.1 Use
More informationBanyan Air Service November 18, 2011 AVE Aviation and Commerce Center Building 1 Miami, FL
SECTION 10801 - TOILET AND BATH ACCESSORIES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions apply to this Section.
More informationHL2024 Constant Flow Solutions
HL2024 Constant Flow Solutions For domestic and professional use Product guide The world s best performing constant flow regulator HL2024 Constant Flow Regulator (cross section) HL2024 constant flow solutions
More informationInstallation Instructions and User Guide 15mm & 22mm Thermostatic Mixing Valve
Installation Instructions and User Guide 15mm & 22mm Thermostatic Mixing Valve TMV3 / TMV2 Combined Valve C85079 C85081 C85080 C85082 It is important that these guidance notes are read and fully understood
More informationDESIGNER FAUCETS & ACCESSORIES
DESIGNER FAUCETS & ACCESSORIES sensible sophistication A rare collection of artistic expressions for the distinctive home environment. Mirabelle is a fusion of form, craftsmanship and function designed
More informationSeries Environmental Chambers
3119-600 Series Environmental Chambers Challenges in Non-Ambient Testing Testing at non-ambient temperatures adds another layer of challenges to your testing laboratory. Ensuring you get accurate and stable
More informationSummary of Substantive Changes between the 2012 and 2018 editions of CSA B125.3 Plumbing Fittings
Summary of Substantive Changes between the 2012 and 2018 editions of CSA B125.3 Plumbing Fittings Presented to the IAPMO Standards Review Committee on October 15, 2018 General: The changes to this standard
More informationOpening and closing force guidelines
Opening and closing force guidelines This document has been complied under guidance of ASDMA membership to provide information on the requirements of Part M of the Building regulations with regards to
More informationOptions Concentric Petite
Options Concentric Petite Thermostatic Mixer Valve with Exposed and Concealed Fitting Options Fitting Instructions IMPORTANT This Step-by-Step guide should be retained after installation. 1. INTRODUCTION
More informationInfection is caused by breathing in small droplets of water contaminated by the bacteria. The disease cannot be passed from one person to another.
DCH05 - Legionella Policy and Procedure Page: 1 of 6 Purpose Scope Policy Protect staff and patients from the risks from legionella. Service Provider and Registered Manager. What is Legionnaires disease?
More informationQUICK CONNECT FOR 2.0, 4.0 & 5.0 GASES
BROEN LAB QUICK CONNECT FOR 2.0, 4.0 & 5.0 ES BROEN LAB QUICK CONNECT FOR 2.0, 4.0 & 5.0 ES BROEN LAB QUICK CONNECT FOR 2.0, 4.0 & 5.0 ES LAB TABLE OF CONTENTS Content Page Table of Content 2 BROEN-LAB
More informationAIR SAVING PRODUCTS ADDING VALUE AIR-SAVER LOCATOR LOCATOR-EV
AIR SAVING PRODUCTS AIR-SAVER LOCATOR LOCATOR-EV ADDING VALUE REL LIABLE COMPRESSED AIR CONDENSATE MANAGEMENT AND ENERGY SAVING PRODUCTS Air saving products INDEX Chapter Content 1 Introduction to compressed
More informationQi Litre Ultrasonic Cleaner
Qi-300 17Litre Ultrasonic Cleaner Ultrawave s Qi-Series are robust and reliable, delivering outstanding cleaning performance in a wide range of industries. From precision, pharmaceutical and medical device
More informationOverview of types. T5-R B2/R B2 en v Subject to changes 1 / 4. k vs (Sequence 2)
Technical data sheet R3015-..-..-B2 / R3020-..-..-B2 Characterised control valves, 6-way, with internal threads Two sequences (cooling/heating) With a rotary actuator 90 Water-side switching or modulating
More informationRAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions
RAM 4021-PR Operation Manual Worldwide Manufacturer of Gas Detection Solutions TABLE OF CONTENTS RAM 4021-PR For Your Safety... 2 Description.... 2 Setup Mode.... 2 Lights/Alarms.... 3 Operation.... 4
More informationRAK Bathrooms. MacDonald Industries Ltd are proud to offer the elegant sanitaryware RAK Ceramics for commercial bathroom.
RAK Bathrooms MacDonald Industries Ltd are proud to offer the elegant sanitaryware RAK Ceramics for commercial bathroom. Wall Faced Toilet Pans Wall Faced Toilet Suites Wall Hung Toilet Pans Accessible
More information1. Introduction. The Easy Guide to TMV3 Approval
THE EASY GUIDE TO TMV3 APPROVAL 1. Introduction NSF approves two categories of Thermostatic Mixing Valves; TMV2 and TMV3. The different valve types are explained in Table 1. TMV3 approval is for thermostatic
More informationCLEANSPACE PRODUCT LIST
PAFtec Australia Pty Ltd Grd Floor, 16-18 Carlotta St Atarmon, NSW 2064 Australia sales@paftec.com CLEANSPACE PRODUCT LIST RESPIRATORS PAF-0034 PAF-0060 EX PAF-0070 ULTRA MASKS PAF-0033 HALF MASK SMALL
More informationUBEC 1AT. AUTO TANK Fill System Installation, Operation, & Setup Instructions
Document Number: XE-ATA5PM-R1A UBEC 1AT AUTO TANK Fill System 08899155 Installation, Operation, & Setup Instructions Rev170906-EB-FRC PHYSICAL: 1302 WEST BEARDSLEY AVE ELKHART, IN 46514 WWW.ELKHARTBRASS.COM
More informationbook : t95575.fm Seite 1 Mittwoch, September 20, :10 AM. Avensys. Exposed Single Lever Mixer
955751.book : t95575.fm Seite 1 Mittwoch, September 20, 2000 10:10 AM Avensys Exposed Single Lever Mixer 33 389 33 396 Installation Instructions and Operating Guide Please leave this document with the
More informationOperating instructions Capacitive sensors KG AC (M18) / / 2010
Operating instructions Capacitive sensors KG AC (M18) UK 704923 / 00 09 / 2010 Contents 1 Preliminary note 3 2 Safety instructions 3 3 Functions and features 3 3.1 Application examples 4 4 Installation
More informationDTG - LCD Digital Temperature Gauge USER MANUAL
DTG - LCD USER MANUAL Page 1 of 7 USERS GUIDE page 1. Description 3 2. Function 3 3. Safety Instruction 3 3.1. Safety Conventions 3 3.2. Proper Use 3 4. Installation 4 4.1. Unpacking 4 4.2. Storage 4 4.3.
More informationOperation and Maintenance of the EPV200 Portable Ventilator
Operation and Maintenance of the EPV200 Portable Ventilator 1 Applications of the EPV200 The EPV200 Portable Ventilator is a gas powered electronically controlled mechanical ventilator, designed to provide
More informationmullen shower base LIFE TIME Suitable for: ALL Floor Types Floor Coverings V Vinyl Wood Flooring Concrete Slab C Ceramic Tiles
mullen shower base Suitable for: ALL Floor Types Wood Flooring Concrete Slab Floor Coverings V Vinyl C Ceramic Tiles L WA R R A N T Y The Mullen 49 7 /8 x 30 1 /8 installed with vinyl floor covering (Altro
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS HIGH PRESSURE PUMP To minimize vibration, it is best to build brackets on the motor itself, similar to alternator brackets. Use cardboard to construct a pattern first before making
More informationhydraulic valve 1 Introduction
CF Range (Cistern Flushing Range) hydraulic valve 1 Introduction the hydraulic valve is an automatic urinal flush control valve. The valve uses a simple patented mechanism which prevents water waste by
More informationGTX. 1 of 9. The GTX scrubber s 2 recover drain and hose are larger than those on many other machines, making the GTX scrubber less likely to clog.
The scrubber uses larger (8 stainless) hinges and bolt directly into the heavy gage steel frame. This provides better durability than other machines that use smaller tank hinges bolted to plastic tanks.
More informationINSTALLATION, CARE & USE MANUAL. EMASMB & LMASMB Surface Mount Bottle Filling Stations
INSTALLATION, CARE & USE MANUAL EMASMB & LMASMB Surface Mount Bottle Filling Stations IMPORTANT THIS IS AN INDOOR APPLICATION ONLY! ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSONNEL. TOOLS/ITEMS
More informationHorne Engineering Ltd
Horne Engineering Ltd Po Box 7, Rankine Street Johnstone, Renfrewshire Scotland, PA5 8BD Tel: 01505 321455 Fax: 01505 336287 Email: technical@horne.co.uk Web: www.horne.co.uk HORNE T105A/106A/107A/108A
More informationPRISM GK Assisted Bathing Systems
PRISM GK Assisted Bathing Systems Superior As sisted Bathing Systems. Highest quality build at value for money prices The Prism GK Assisted Bath Range provides a multitude of bathing solutions for a wide
More informationRAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions
RAM 4021 Operation Manual Worldwide Manufacturer of Gas Detection Solutions TABLE OF CONTENTS RAM 4021 For Your Safety... 2 Description.... 2 Setup Mode.... 2 Lights/Alarms.... 3 Operation.... 4 Calibration....
More informationUltrasonic baths. XUB range of digital ultrasonic baths. XUBA range of analogue ultrasonic baths. Digitally controlled range with a choice of 5 baths
7 Ultrasonic baths XUB range of digital ultrasonic baths Digitally controlled range with a choice of 5 baths XUBA range of analogue ultrasonic baths Entry level baths with analogue controls Ultrasonic
More informationPrecision matters. HiQ equipment for specialty gases.
Precision matters. HiQ equipment for specialty gases. Pure, precise, reliable solutions. HiQ equipment. The application of specialty gases demands well-founded expertise and professional know-how. HiQ
More informationRada Sense Shower T3 DMV PRODUCT MANUAL IMPORTANT
Rada Sense Shower T3 DMV PRODUCT MANUAL IMPORTANT Installer: This Manual is the property of the customer and must be retained with the product for maintenance and operational purposes. 1 CONTENTS Description...3
More informationSEQUENTIAL SHOWER VALVE INSTRUCTION MANUAL PLEASE LEAVE THIS MANUAL WITH THE END USER
SEQUENTIAL SHOWER VALVE INSTRUCTION MANUAL PLEASE LEAVE THIS MANUAL WITH THE END USER CONTENTS 1. INTRODUCTION & SAFETY 1 2. DIMENSIONS 2 3. TECHNICAL DATA 3 4. OPERATION 4 5. COMPONENTS 5 6. SITE INSTALLATION
More informationThermostatic Concentric Mixer Valve. with Exposed and Concealed Fitting Options. Fitting Instructions
Atmos Fusion Thermostatic Concentric Mixer Valve with Exposed and Concealed Fitting Options Fitting Instructions IMPORTANT This Step-by-Step guide should be retained after installation. 1. INTRODUCTION
More informationAmerican Standard. Selectronic Remote Control Operating Manual M965370
American Standard Selectronic Remote Control Operating Manual M9670 Transmission Area DISPLAY OPERATION: The remote programmer has 4 keys: Enter or validate Cancel Scroll UP Scroll Down Mini-USB Port The
More informationMEDICAL EQUIPMENT CATALOG
THE MOST TRUSTED MEDICAL EQUIPMENT IN NORTH AMERICA MEDICAL EQUIPMENT CATALOG Total Components Including Bulk Oxygen Supply, Back up and Delivery Equipment Designs for High Pressure, Liquid or Bulk Applications
More informationDräger PSS 7000 SCBA Self-Contained Breathing Apparatus
Dräger PSS 7000 SCBA Self-Contained Breathing Apparatus Before you can protect the lives of others, you have to protect yourself. The Dräger PSS 7000 SCBA breathing apparatus provides unmatched comfort,
More informationModel PSI Compressor with 3-Gallon Air Tank 12VDC
Model 6350 150 PSI Compressor with 3-Gallon Air Tank 12VDC IMPORTANT: It is essential that you and any other operator of this product read and understandd the contents of this manual before installing
More informationWater Pressure Reducing Valves
Water Pressure Reducing Valves Controlling Water Pressure in Residential, Commercial, and OEM Applications Watts.com The One-stop Shop for Pressure Regulators Watts is the manufacturer of choice for Water
More informationABB MEASUREMENT & ANALYTICS DATA SHEET. AP100 ph/redox (ORP) cartridge sensors with water-wash option
ABB MEASUREMENT & ANALYTICS DATA SHEET AP100 ph/redox (ORP) cartridge sensors with water-wash option 2 AP100 P H / R EDOX ( ORP ) CART RI D GE SE NSORS WITH WATE R-WASH OPTION DS/AP100-E N RE V. K Measurement
More informationbetter measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.
Simply a question of better measurement SCHMIDT Flow Sensor SS 20.261 The cost-effective alternative in pressurised systems up to 10 bars. Compressed air technology Industrial processes A cost analysis
More informationWHATEVER YOUR NEEDS, WE HAVE A STYLE TO SUIT YOU
WHATEVER YOUR NEEDS, WE HAVE A STYLE TO SUIT YOU ALL INCLUSIVE WALK-IN BATHS 3 Commonwealth Close, Leigh Business Park, Leigh WN7 3BD T: 0800 012 4257 www.localmobility.co.uk CONTENTS LOCAL MOBILITY ALL
More informationRada-Presto TF2020 and TF2020S
Rada-Presto TF2020 and TF2020S PRODUCT MANUAL IMPORTANT Installer: This Manual is the property of the customer and must be retained with the product for maintenance and operational purposes. 1 INDEX Page
More informationDirect Operated Precision Regulator Modular Style. Standard Specifications
1 Direct Operated Precision Regulator Modular Style Series P3 Courtesy of Steven Engineering, Inc.-23 Ryan Way, South San Francisco, CA 948-637-Main Office: (65) 588-92-Outside Local Area: (8) 258-92-www.stevenengineering.com
More informationNIMBUS range. with people in mind
NIMBUS range Advanced Mattress Replacement systems with people in mind OPTIMUM PRESSURE RELIEF AND COMFORT In clinical use for more than 20 years, Nimbus Alternating Mattress Replacement Systems have consistently
More informationRecommendations on Checking Anaesthesia Delivery Systems
Page 1 of 11 Recommendations on Checking Anaesthesia Delivery Version Effective Date 1 Oct 1992 (reviewed Feb 07, Feb 02) 2 2004 3 Nov 2011 4 Dec 2016 Document No. HKCA T1 v4 Prepared by College Guidelines
More informationLatvin Luxury Shower Panel. Telephone Product Specification. ~ Minimum Working Pressure 1.0 bar ~ Maximum Working Pressure 3.
Product Specification ~ Minimum Working Pressure 1.0 bar ~ Maximum Working Pressure 3.0 bar Latvin Luxury Shower Panel ~ Fixing Centres 150mm +/- 10mm ~ Outlet size 1/2" Bottom Outlet Always maintain a
More informationPresented to the IAPMO Standards Review Committee on March 7, 2016
Summary of Substantive Changes between the 2015 edition of ASSE 1070/ASME A112.1070/CSA B125.70, Water Temperature Limiting Devices, the 2004 edition of ASSE 1070, Water Temperature Limiting Devices, and
More informationInstallation/Care/Use Manual
Installation/Care/Use Manual EMASM Surface Mount Bottle Filling Station IMPORTANT THIS IS AN INDOOR APPLICATION ONLY! ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSONNEL. TOOLS/ITEMS REQUIRED
More informationIBEDA GAS MIXERS HIGHEST PRECISION FOR YOUR WELDING AND CUTTING PROCESSES
IBEDA GAS MIXERS HIGHEST PRECISION FOR YOUR WELDING AND CUTTING PROCESSES GAS SAFETY ENGINEERING GAS MANIFOLD SYSTEMS AUTOGENOUS ENGINEERING FLAME SPRAYING GAS MIXERS IBEDA GAS MIXERS FOR MANY AREAS OF
More information