Filter Housings. Universal & Compact Multi-Chamber Filter Housings

Size: px
Start display at page:

Download "Filter Housings. Universal & Compact Multi-Chamber Filter Housings"

Transcription

1 Filter Housings engineer approved Universal & Compact Multi-Chamber Filter Housings White Knight dual- and quad-chamber filter housings fit standard filter cartridges offered by major suppliers. They provide high-flow performance, and reliable sealing that can be tightened after initial compression loads. These compact filter housings eliminate additional plumbing and welding, and offer various fitting options. Advanced Technologies Fits major filter cartridges Reliable double O-ring seals Compact layouts reduce footprint Adjustable seals Eliminates additional plumbing and welding Various fitting options 2 PURITY ULTRA HIGH RECIRC. / DELIVERY Low pressure drop Easy to install Greater filtration surface area with up to 3.2-in diameter filters Features & Benefits Compatible with major filter cartridges Nonmetal PTFE/PFA liquid paths Compact layouts with configurable fitting locations, sizes and types Filters in parallel or series operation Up to 3.2-in filter diameters for greater filtration surface area Eliminates leak paths and the need to plumb or weld many housings together to reduce costs, save time, and save valuable space. Easy to configure, install and service Compact, durable design with minimal parts Leak-free dual-static crush seals Low pressure drop (1-in flow path) Max pressure at 25 C is 7 Bar, 100 psi Max pressure at 100 C is 3 Bar, 45 psi 10 in. 20 in. Dual-Static Crush Seal Two O-rings in an angled load system ensure reliable seals to prevent leaks. Sealing pressure can be adjusted beyond initial compression loads. UP TO 7 BAR / 100 PSI TEMPERATURE Why White Knight? UP TO 100 C 212 F Our PTFE/PFA filter housing fit all standard filter cartridges and sizes offered by major suppliers. They have port options on the front, back, sides, and bottom/ top. They include inlet and outlet fittings, vent and drains. Their unique design provides greater surface area and eliminates leak paths and the need to plumb or weld multiple housings together. This reduces costs, saves time, and may reduce footprint by 50%. Dual-static crush seals maintain pressure and prevent leaks, which improves reliability, and eliminates costly downtime and expensive cleanup. Version: Published: 7 Jun 2017 P. 1

2 Dual-Chamber Parallel (FHA-02-P) Fluid goes through all chambers simultaneously greatly reducing pressure drop. Compare to traditional filter housings 2-Chamber Parallel Filter Housing Liquid Inlet Pre-Filter Vent/Drain Post Filter Vent/Drain FHA-02 Traditional 2-Chamber Parallel Filter Housing FHA-02-P Dimensions Traditional Parallel Housing Version: Published: 7 Jun 2017 P. 2

3 Quad-Chamber Parallel (FHA-04-P) Fluid goes through all chambers simultaneously greatly reducing pressure drop. Compare to traditional filter housings 4-Chamber Parallel Filter Housings FHA-04 Four Traditional Housings in Parallel Liquid Inlet Pre-Filter Vent/Drain Post Filter Vent/Drain Traditional Parallel Housing FHA-04-P Dimensions Version: Published: 7 Jun 2017 P. 3

4 Dual-Chamber Series/In-Line (FHA-02-S) Fluid goes through first chamber and then through an additional chamber, which increases filtration and reduces pressure drop. Compare to traditional filter housings 2-Chamber Series Filter Housing Liquid Inlet Pre-Filter Vent/Drain Post Filter Vent/Drain Intermediate Filter Vent/Drain FHA-02 Two Traditional Housings in Series FHA-02-S Dimensions Traditional In-Line Housing Version: Published: 7 Jun 2017 P. 4

5 Quad-Chamber Series/In-Line (FHA-02-S) Fluid flows through first two chambers and then through the next two chambers, which increases filtration and reduces pressure drop. Compare to traditional filter housings 4-Chamber Series Filter Housing FHA-04 Liquid Inlet Pre-Filter Vent/Drain Post Filter Vent/Drain Intermediate Filter Vent/Drain Four Traditional Housings in Series FHA-04-S Dimensions Traditional In-Line Housing Version: Published: 7 Jun 2017 P. 5

/ /

/ / GN 4- kw/5.5-0 hp Dual Output Compressors (Air/Nitrogen) Driving Nitrogen Forward GN: the dual output solution From cargo blanketing in LNG vessels to the inflation of Formula tires, nitrogen is used in

More information

www.ompressedairsystems.com ultra-high purity nitrogen generators nitrogen purity: 95% to 99.999% www.ompressedairsystems.com ultra-high purity nitrogen generators nitrogen purity: 95% to 99.999% Leading

More information

Design. Pompetravaini-NSB API SB Liquid Ring Compressor for Gas Processing. Working Principle

Design. Pompetravaini-NSB API SB Liquid Ring Compressor for Gas Processing. Working Principle SB Pompetravaini-NSB API SB Liquid Ring Compressor for Gas Processing A family of API liquid ring compressors has been developed and has been in the market for nearly a decade, they are specifically made

More information

FIK In-Tank Filters FIK. Max Flow: 170 gpm (643 lpm) Working Pressures to: Rated Static Burst to: Flow Range to:

FIK In-Tank Filters FIK. Max Flow: 170 gpm (643 lpm) Working Pressures to: Rated Static Burst to: Flow Range to: LOW PRESSURE FILTERS Max Flow: gpm ( lpm) In-Tank Filters Working Pressures to: Rated Static Burst to: psi kpa bar psi kpa bar Flow Range to: gpm lpm Features STYLE C STYLE D STYLE E in-tank filters are

More information

GREIG FILTERS, INC. OPERATION MANUAL

GREIG FILTERS, INC. OPERATION MANUAL GREIG FILTERS, INC. OPERATION MANUAL MODEL DCFH 3P 15/3 100 S4 DOE/222 DUAL CARTRIDGE FILTER HOUSING TABLE OF CONTENTS I. INTRODUCTION II. CARTRIDGE FILTER HOUSING UNIT A. OPERATION B. INSTALLATION C.

More information

4-7 kw/ hp. Dual Output Compressors (Air/Nitrogen) Driving Nitrogen Forward

4-7 kw/ hp. Dual Output Compressors (Air/Nitrogen) Driving Nitrogen Forward GN 4-7 kw/5.5-10 hp Dual Output Compressors (Air/Nitrogen) Driving Nitrogen Forward Total capability, total responsibility Right at the heart of your business, Atlas Copco delivers quality compressed air

More information

Your local gas generation partner. Precision series Modular gas generation solution for GC.

Your local gas generation partner. Precision series Modular gas generation solution for GC. Your local gas generation partner Precision series Modular gas generation solution for GC www.peakscientific.com Perform with Precision Specifically designed and engineered for GC laboratory applications,

More information

Calibrated or locked versions available. TREATMENT > Series MD regulators GENERAL DATA. New

Calibrated or locked versions available. TREATMENT > Series MD regulators GENERAL DATA. New > Series MD regulators Series MD pressure regulators New Ports with interchangeable cartridges: threaded (1/8, 1/4, /8) or integrated with super-rapid fitting for tube with Ø 6, 8 and 10 mm Versions: single,

More information

Description Advanced Features Typical Applications

Description Advanced Features Typical Applications Series single stage, brass barstock line regulator Description Advanced Features Typical Applications The Series regulators are intended for secondary pressure control of noncorrosive, high purity or liquefied

More information

Reverse Osmosis System Installation Guide and Operation Manual.

Reverse Osmosis System Installation Guide and Operation Manual. Reverse Osmosis System Installation Guide and Operation Manual. Table of Contents 1 Introduction...2 2 Installation...3 2.1 Feed water connection...3 2.2 Permeate and concentrate plumbing...3 2.3 Electrical

More information

SPECIFICATIONS. Approximate Weight: 10 oz. Surface Finish: Ra micro inch or less MATERIALS OF CONSTRUCTION

SPECIFICATIONS. Approximate Weight: 10 oz. Surface Finish: Ra micro inch or less MATERIALS OF CONSTRUCTION DIFFUSION-RESISTANT, DIAPHRAGM SEAL, EXCESS FLOW SHUT-OFF VALVES (FS SERIES) FS Series Excess Flow Shut-Off Valves are designed to automatically shut-off the delivery of gas in a line if the flow exceeds

More information

Eaton Filtration, LLC

Eaton Filtration, LLC Eaton Filtration, LLC 900 Fairmount Avenue, Elizabeth, NJ 07207 Phone: 908-787-1000 Fax: 908-351-7893 E-Mail: filtration@eaton.com Web: www.filtration.eaton.com Installation, Operation & Service Manual

More information

Eaton Filtration, LLC

Eaton Filtration, LLC Eaton Filtration, LLC 900 Fairmount Avenue, Elizabeth, NJ 07207 Phone: 908-787-1000 Fax: 908-351-7893 E-Mail: filtration@eaton.com Web: www.filtration.eaton.com Installation, Operation & Service Manual

More information

Flow control valves Series RFU - RFO 2/

Flow control valves Series RFU - RFO 2/ CATALOGUE > Release 8.5 > Valves Series RFU - RFO Flow control valves Series RFU - RFO Unidirectional and bidirectional flow control valves Ports: M5, G1/8, G1/4, G3/8 and G1/ Nominal diameter: M5 = 1,5

More information

Providing the Benefits of Seitz Filter Media in the Most Versatile Capsule Format Available

Providing the Benefits of Seitz Filter Media in the Most Versatile Capsule Format Available Rev. Date: 23-Jun-2010 Supracap 100 Depth Filter Capsules Description Providing the Benefits of Seitz Filter Media in the Most Versatile Capsule Format Available Scalability is critical to safe and reliable

More information

Chemgard Filter Housings

Chemgard Filter Housings Contamination Control Solutions Chemgard Filter Housings Installation and use manual Table of Contents Introduction... 2 Safety... 2 Specifications... 3 PVDF... 3 PP... 3 PFA In-line... 3 Installation...

More information

Operation Manual. Diaphragm Sensed Gas Pressure Regulators

Operation Manual. Diaphragm Sensed Gas Pressure Regulators 687 Technology Way Napa, CA 94558 Phone: (707) 259-0102 FAX: (707) 259-0117 www.aptech-online.com Diaphragm Sensed Gas (AP/AZ/AK Models: 20, 100, 500, 1000, 1000T 10PA, 1100, 1200, 12PA, 1300, 1400T, 14PA,

More information

Simplicity in VRU by using a Beam Gas Compressor

Simplicity in VRU by using a Beam Gas Compressor Simplicity in VRU by using a Beam Gas Compressor By Charlie D. McCoy and Mark Lancaster Abstract: Vapor Recovery Units are often expensive, complicated to operate and unable to deal with High H2S and liquids.

More information

HIGH PRESSURE FILTERS DFDK Series Inline Duplex Filters 4568 psi up to 90 gpm

HIGH PRESSURE FILTERS DFDK Series Inline Duplex Filters 4568 psi up to 90 gpm DFDK Series Inline Duplex Filters 4568 psi up to 9 gpm Hydraulic Symbol DFDK QL L Ball Valve A DFDK QT T Ball Valve (sizes 33 or larger) A B B Features The DFDK Filters have a filter head of ductile iron

More information

Your local gas generation partner. Precision series Modular gas generation solution for GC.

Your local gas generation partner. Precision series Modular gas generation solution for GC. Your local gas generation partner Precision series Modular gas generation solution for GC www.peakscientific.com Perform with Precision Specifically designed and engineered for GC laboratory applications,

More information

Load Controls Screw In Cartridge Valves Pressures to 350 bar (5000 psi) Flows to 190 l/min (50 USgpm)

Load Controls Screw In Cartridge Valves Pressures to 350 bar (5000 psi) Flows to 190 l/min (50 USgpm) Vickers Cartridge Valves Load Controls Screw In Cartridge Valves Pressures to 50 bar (5000 psi) Flows to 90 l/min (50 USgpm) Rev. 2/99 722 Contents MODEL DESCRIPTION TYP. APPLICATION PRESSURE bar (psi)

More information

REFRIGERATION SYSTEM COMPONENTS

REFRIGERATION SYSTEM COMPONENTS REFRIGERATION SYSTEM COMPONENTS henrytech.com Conventional Oil Separators The function of an Oil Separator is to remove oil from the discharge gas and return it to the Compressor either directly or through

More information

Manual. Bypass Feeder. Installation Maintenance Repair Manual. Chemical Addition and Filtering

Manual. Bypass Feeder. Installation Maintenance Repair Manual. Chemical Addition and Filtering Manual Bypass Feeder Chemical Addition and Filtering Installation Maintenance Repair Manual Advantage Controls P.O. Box 1472 Muskogee, OK 74402 Phone: 918-686-6211 Fax: 918-686-6212 www.advantagecontrols.com

More information

Your local gas generation partner. Precision series Modular gas generation solution for GC.

Your local gas generation partner. Precision series Modular gas generation solution for GC. Your local gas generation partner Precision series Modular gas generation solution for GC www.peakscientific.com Perform with Precision Specifically designed and engineered for GC laboratory applications,

More information

FILTER REGULATORS MODEL NO: CAT155 & CAT156 FITTING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS

FILTER REGULATORS MODEL NO: CAT155 & CAT156 FITTING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS FILTER REGULATORS MODEL NO: CAT155 & CAT156 PART NO: 3120169 & 3120170 FITTING & MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS GC0117 INTRODUCTION Thank you for purchasing this CLARKE Filter/Regulator.

More information

SERVICE MANUAL MODEL BA020ANM-S1 BREATHING AIR PANEL

SERVICE MANUAL MODEL BA020ANM-S1 BREATHING AIR PANEL SERVICE MANUAL MODEL BA020ANM-S1 BREATHING AIR PANEL WARNING: Do not attempt to operate this equipment without first reading and understanding the service manual enclosed with this device. 6/08 2 GENERAL

More information

Change-Over Pressure Filter DFDK

Change-Over Pressure Filter DFDK Change-Over Pressure Filter up to 8 l/min, up to 35 bar 3 6 4 6 4 8 33 5 66.x 66.x 99.x 3.x 3 3.x 64 3.x 396 3.x. TECHNICAL SPECIFICATIONS. FILTER HOUSING Construction The filter housings are designed

More information

Full Range Pressure Compensating Variable Flow Control

Full Range Pressure Compensating Variable Flow Control Engineering & Manufacturing Solutions Specifications: See flow chart for capacity. Rated for 3000 psi (207 bar). Weighs 7- ¾ lbs. (3.52 kg). 30-Micron Filtration Recommended. Torque to turn side lever

More information

1020 Industrial Drive, Orlinda, TN fax

1020 Industrial Drive, Orlinda, TN fax Operation Manual Ultrafiltration for High Purity Distribution K-A-HPTUF Series 615-654-4441 sales@specialtyh2o.com 615-654-4449 fax TABLE OF CONTENTS Section 1 GENERAL 1.1 Warnings and Cautions... 1 1.2

More information

HP/UHP Spring-Loaded Regulator

HP/UHP Spring-Loaded Regulator Description HP (High Purity) and UHP (Ultra High Purity) products are for service where the product must be kept free of contamination. The design is kept simple to minimise dead areas where contaminants

More information

SERVICE MANUAL MODEL BA020AMST BREATHING AIR PANEL

SERVICE MANUAL MODEL BA020AMST BREATHING AIR PANEL SERVICE MANUAL MODEL BA020AMST BREATHING AIR PANEL WARNING: Do not attempt to operate this equipment without first reading and understanding the service manual enclosed with this device. 5/08 2 GENERAL

More information

TechTalk. Purging for Delayed Coking. Understanding purging system design in heavy-fouling applications. Outline

TechTalk. Purging for Delayed Coking. Understanding purging system design in heavy-fouling applications. Outline Page 1 of 6 TechTalk Understanding purging system design in heavy-fouling applications Purging for Delayed Coking Outline Introduction In high-fouling applications such as heavy oil processing and What

More information

Kinetics Fluid Systems - Process Flow Products. 18 February

Kinetics Fluid Systems - Process Flow Products. 18 February 18 February 2002 1 THE MODULAR SYSTEM - History 1995 -Unit Instruments, Inc. introduced Z-Z Block Modular system for Semiconductor marketplace 1997 - Increasing acceptance of modular technology in semiconductor

More information

Detector Carrier Gas Comments Detector anode purge or reference gas. Electron Capture Nitrogen Maximum sensitivity Nitrogen Argon/Methane

Detector Carrier Gas Comments Detector anode purge or reference gas. Electron Capture Nitrogen Maximum sensitivity Nitrogen Argon/Methane Gas requirements Gases for packed columns The carrier gas you use depends upon the type of detector and the performance requirements. Table 520-1 lists gas recommendations for packed column use. In general,

More information

Tradition & Technology

Tradition & Technology Gaterotor Support Gaterotor Single Screw Compressors Design & Operation Bearing Bearings Main Screw Parallex Slide System The VSM Single Screw Compressor has one main rotor and two gaterotors. All bearings

More information

829S1 Series Flexflo Pilot

829S1 Series Flexflo Pilot REDQ Regulators The Model 829S1 Provides Versatile Pressure Regulation At An Economical Price. The Model 829S1 Flexflo Pilot is a reversible pressure control regulator (seat & nozzle) that is used in conjunction

More information

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator. RS(H)10,15 USER MANUAL Read the complete manual before installing and using the regulator. WARNING INCORRECT OR IMPROPER USE OF THIS PRODUCT CAN CAUSE SERIOUS PERSONAL INJURY AND PROPERTY DAMAGE. Due to

More information

shutoff valves 900 Series psig Manual Shutoff Valves

shutoff valves 900 Series psig Manual Shutoff Valves 0 6000 psig Manual Shutoff Valves Features Zero leakage Protected o-ring Full flow passages Freedom from wire drawing Panel mount standard Hand wheel or toggle handle How it Works Closed O-ring seal on

More information

F68G - Olympian Plus plug-in system General purpose filter

F68G - Olympian Plus plug-in system General purpose filter > > Port size: /... / (ISO G/ PTF) > > Olympian Plus plug in system > > Large filter element area provides minimum pressure drop > > Effective liquid removal and positive solid particle filtration Technical

More information

First Stage Regulators

First Stage Regulators DOMESTIC First stage regulators are typically used to reduce tank pressure to an intermediate pressure, usually 5 to 10 PSI for further pressure reduction by a second stage regulator located closer to

More information

Quality filter cartridges and customized housings.

Quality filter cartridges and customized housings. Single Cartridge & Plastic Housings Multi Cartridge Housings Bag Housings & MicroSentry Bags Jumbo Housings & Cartridges Quality filter cartridges and customized housings. www.shelco.com Stacked Disc Housings

More information

1200 Series Pressure Regulators

1200 Series Pressure Regulators SEE MORE AT SORInc.com Request Quote 1200 Series Pressure SOR pressure regulators are durable, high performing instruments that are designed to provide reliable control of pressure in various stages of

More information

TROUBLESHOOTING GUIDELINES

TROUBLESHOOTING GUIDELINES TROUBLESHOOTING GUIDELINES PROBLEM: Performance 1. The most common problem in this area comes from inadequate flow to the LAKOS Separator(s). All LAKOS Separators operate within a prescribed flow range

More information

e G) GOVERNOR t,5 ii:i! Line Pressure Regulators

e G) GOVERNOR t,5 ii:i! Line Pressure Regulators Line Pressure Regulators @ - c - e G) t,5 ii:i! 1rlr1t APPLICATION NOTES 1rlr1t A. The Governor regulator is ANSI Z21.80a and ANSI Z21.18 certified for vent limited installations (indoor installations

More information

CHE Well Testing Package/Service:

CHE Well Testing Package/Service: CHE Well Testing Package/Service: CHE delivers well testing package And services, trailer mounted well testing package and offshore/onshore well testing services with over 10 years experience. Our testing

More information

FloWash. Industrial Filter Cart

FloWash. Industrial Filter Cart OPERATION AND MAINTENANCE MANUAL FloWash Industrial Filter Cart Read all instructions before installation or operation of equipment. Failure to comply with these instructions could result in bodily injury

More information

e G) GOVERNOR t,5 ii:i! Line Pressure Regulators

e G) GOVERNOR t,5 ii:i! Line Pressure Regulators Line Pressure Regulators @ - c - e G) t,5 ii:i! 1rlr1t APPLICATION NOTES 1rlr1t A. The Governor regulator is ANSI Z21.80a and ANSI Z21.18 certified for vent limited installations (indoor installations

More information

THE DELIVERY OF GAS SUPPLY

THE DELIVERY OF GAS SUPPLY GAS ASSIST INJECTION MOLDING THE DELIVERY OF GAS SUPPLY April 2010 www.bauerptg.com THE DELIVERY OF GAS SUPPLY Gas assist requires a source of high-pressure nitrogen gas that can be controlled and delivered

More information

Water Pressure Reducing Valves

Water Pressure Reducing Valves Water Pressure Reducing Valves Controlling Water Pressure in Residential, Commercial, and OEM Applications Watts.com The One-stop Shop for Pressure Regulators Watts is the manufacturer of choice for Water

More information

Table of Contents - ALpHA Filters

Table of Contents - ALpHA Filters ALpHA Filters 1 Table of Contents - ALpHA Filters Materials of Construction 3 Dimensions 4 Operating Characteristics 5 Particle Retention Data 6 Cartridge Installation Instructions 7 Autoclave Instructions

More information

LAKOS Waterworks. PWC Series Sand Separators. Installation & Operation Manual LS-829 (10/12)

LAKOS Waterworks. PWC Series Sand Separators. Installation & Operation Manual LS-829 (10/12) LAKOS Waterworks PWC Series Sand Separators Installation & Operation Manual LS-829 (10/12) Table of Contents Separator Operation... 3 Individual Model Details.... 4 Flow vs. Pressure Loss Chart 4 Installation

More information

Product Sheet Spraymist Unit

Product Sheet Spraymist Unit Product Sheet Spraymist Unit DESCRIPTION The Spraymist unit is perfectly adapted for use with differents liquids for applications as metalcutting, drilling, grinding, cooling or wetting processes and chain

More information

Modular Venturi Vacuum Pumps Miniature Venturi Vacuum Pump with Silencer Fastvac Mini Series: VP00 VP00-60H picks and places IC chips on circuit board

Modular Venturi Vacuum Pumps Miniature Venturi Vacuum Pump with Silencer Fastvac Mini Series: VP00 VP00-60H picks and places IC chips on circuit board iniature Venturi Vacuum Pump with Silencer Fastvac ini Series: VP00 VP00-60 picks and places IC chips on circuit boards Standard Pump: The VP00 Fastvac ini Series air-powered venturi vacuum pumps are highly

More information

SDV Single Diaphragm Valve On/Off Manual/Pneumatic Flare, S-300, FNPT, Tube 58 psi 1/4-1/ psi 3/4-1

SDV Single Diaphragm Valve On/Off Manual/Pneumatic Flare, S-300, FNPT, Tube 58 psi 1/4-1/ psi 3/4-1 Diaphragm Valves Excellent durability and reliability Ideal for CMP Slurry, DI water & Chemical Process Easily incorporated into OEM equipment Specific solutions for your application SDV Single Diaphragm

More information

Integrity Testing LifeASSURE BNA045 and BNA065 Series Filter Cartridges

Integrity Testing LifeASSURE BNA045 and BNA065 Series Filter Cartridges Integrity Testing LifeASSURE BNA045 and BNA065 Series Filter Cartridges SAFETY INFORMATION Read, understand, and follow all safety information contained in these instructions and the instructions provided

More information

Air Operated Hydraulic Pumping Systems to 50,000 psi

Air Operated Hydraulic Pumping Systems to 50,000 psi High Pressure Equipment Air Operated Hydraulic Pumping Systems to 50,000 psi PS-10: 10,000 psi PS-20: 20,000 psi PS-30: 30,000 psi PS-40: 40,000 psi PS-50: 50,000 psi PS-90: 90,000 psi High Pressure air

More information

HighVac Pumps. High Vacuum Venturi Pumps. Modular Venturi Vacuum Pumps with Solenoid-Operated Vacuum and Blow-Off

HighVac Pumps. High Vacuum Venturi Pumps. Modular Venturi Vacuum Pumps with Solenoid-Operated Vacuum and Blow-Off Modular Venturi Vacuum Pumps with Solenoid-Operated Vacuum and Blow-Off Vaccon offers a High Vacuum Venturi Pump in a variety of performance ranges. Each HighVac Series Pump is capable of 29.5 Hg [999mbar]

More information

Operation Manual Piston Sensed Gas Pressure Regulators

Operation Manual Piston Sensed Gas Pressure Regulators 687 Technology Way Napa, CA 94558 Phone: (707) 259-0102 FAX: (707) 259-0117 www.aptech-online.com Operation Manual Piston Sensed Gas Pressure Regulators (Models KT9, KT10, Welded KT10, KT12) Table of Contents:

More information

SERVICE MANUAL MODEL BA200AMST-S1 BREATHING AIR PANEL

SERVICE MANUAL MODEL BA200AMST-S1 BREATHING AIR PANEL 1 SERVICE MANUAL MODEL BA200AMST-S1 BREATHING AIR PANEL WARNING: Do not attempt to operate this equipment without first reading and understanding the service manual enclosed with this device. 2 GENERAL

More information

Balston Nitrogen Generation Systems

Balston Nitrogen Generation Systems Lower cost...eliminates the need for costly gas cylinders Complete package with prefilters, final filters, and receiving tank Compact - frees up valuable floor space Eliminates unexpected shutdowns due

More information

Pharmaceutical Bubble Trap Standard Design Features

Pharmaceutical Bubble Trap Standard Design Features Pharmaceutical Bubble Trap Standard Design Features CLICK TO PLAY Mouse over for details 7 taper Self enclosed tie rod threads Shouldereded tie rods 7 taper Smooth welds Soft radii Crevice free design

More information

LRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator.

LRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator. LRS(H)4 USER MANUAL Read the complete manual before installing and using the regulator. WARNING INCORRECT OR IMPROPER USE OF THIS PRODUCT CAN CAUSE SERIOUS PERSONAL INJURY AND PROPERTY DAMAGE. Due to the

More information

Table of Contents - Ultradyne Filters

Table of Contents - Ultradyne Filters Ultradyne Filters 1 Table of Contents - Ultradyne Filters Materials of Construction 3 Dimensions 4 Operating Characteristics 5 Cartridge Installation Instructions 6 Integrity Test: Manual Bubble Point

More information

Desiccant Air Breathers DBE. Section 3: TNK SCHROEDER INDUSTRIES ACCESSORIES 21

Desiccant Air Breathers DBE. Section 3: TNK SCHROEDER INDUSTRIES ACCESSORIES 21 Desiccant Air Breathers DBE Section 3: SCHROEDER INDUSTRIES ACCESSORIES 21 Reservoir Accessories A hydraulic systems reservoir can play a significant role in the ingression of contamination into the system.

More information

JSR Series. Sanitary Valves JSR Series Ultra-High Pressure Reducing Valves. High Purity Bio-Pharma Gas Pressure Reducing Valves.

JSR Series. Sanitary Valves JSR Series Ultra-High Pressure Reducing Valves. High Purity Bio-Pharma Gas Pressure Reducing Valves. JSR Series High Purity Bio-Pharma Gas Pressure Reducing Valves JSR is the first high purity gas pressure regulator designed and built specifically for hygienic, ASME BPE gas applications. Traditionally,

More information

Installation, Operation, and Maintenance Manual

Installation, Operation, and Maintenance Manual Installation, Operation, and Maintenance Manual Welker Dehydration Assembly Model DA-1 Drawing No.: AD079CO, AD285CR Manual No.: IOM-018 The information in this manual has been carefully checked for accuracy

More information

Series MX pressure regulators 3/

Series MX pressure regulators 3/ CATALOGUE > Release 8.8 > Series MX regulators Series MX pressure regulators MX2 ports: G/8, G1/2, G/4 - MX ports: G/4, G1 Manifold ports: G1/2 (MX2 only) Modular - Available with built-in pressure gauges

More information

PULSATION DAMPENER / SUPPRESSOR SERIES PDS PROVIDES MULTIPLE SYSTEM SAFEGUARDS

PULSATION DAMPENER / SUPPRESSOR SERIES PDS PROVIDES MULTIPLE SYSTEM SAFEGUARDS PULSATION / SUPPRESSOR SERIES PDS PROVIDES MULTIPLE SYSTEM SAFEGUARDS FUNCTIONS: 1. Pulsation Dampener smooths pump flow 2. Surge Suppressor absorbs shocks and vibrations 3. Water Hammer Arrestor eliminates

More information

Discontinued. Powers Controls. Technical Instructions Document No P25 RV Rev. 1, May, RV 201 Pressure Reducing Valves.

Discontinued. Powers Controls. Technical Instructions Document No P25 RV Rev. 1, May, RV 201 Pressure Reducing Valves. Powers Controls RV 201 Pressure Reducing Valves Description Features Product Numbers Dual Pressure PRV Technical Instructions Document No. 155-049P25 RV 201-1 Single Pressure PRV The RV 201 Pressure Reducing

More information

MF2M Monnier Miniature Compressed Air Filter

MF2M Monnier Miniature Compressed Air Filter 5040050 / 2 IM-P504-02 CH Issue 2 MF2M Monnier Miniature Compressed Air Filter Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation and commissioning

More information

Standard Operating and Maintenance Instructions for Pumping System Model PS-90

Standard Operating and Maintenance Instructions for Pumping System Model PS-90 Standard Operating and Maintenance Instructions for Pumping System Model PS-90 High Pressure Equipment Company 2955 West 17th Street, Suite 6 PO Box 8248 Erie, PA 16505 USA 814-838-2028 (phone) 814-838-6075

More information

JSRH Series. Sanitary Valves JSRH Series High Flow Pressure Reducing Valves. High Flow Bio-Pharma Clean Gas Pressure Reducing Valves

JSRH Series. Sanitary Valves JSRH Series High Flow Pressure Reducing Valves. High Flow Bio-Pharma Clean Gas Pressure Reducing Valves JSRH Series High Flow Bio-Pharma Clean Gas Pressure Reducing Valves The JSRH Series high purity gas pressure regulator was designed and built specifically for Bio-Pharma gas applications. It may also be

More information

AIR DRIVEN. Gas Boosters & SYSTEMS. Accepting VISA, MasterCard and American Express

AIR DRIVEN. Gas Boosters & SYSTEMS. Accepting VISA, MasterCard and American Express AIR DRIVEN Gas Boosters & SYSTEMS Accepting VISA, MasterCard and American Express Gas Boosters AIR DRIVEN FROM 30 PSI TO 21,750 PSI MAXIMATOR Maximator gas boosters are an excellent alternative to high

More information

Nitrogen Tyre Inflator Owner s Manual

Nitrogen Tyre Inflator Owner s Manual Nitrogen Tyre Inflator Owner s Manual Model:PN-8890 Please read this manual carefully before attempting assembly or use. 1 Suit for: Motorcycle, Car, Light Truck, Bus Manual Model Nitrogen Tyre Inflation

More information

Refrigerant Gases Valves

Refrigerant Gases Valves Refrigerant Gases Valves RUS series Single Outlet Compact Refrigerant Recovery Valves 46 RDU series Diaphragm Packless Multivalves for Refrigerant Gases 47 RBV series Single Outlet Diaphragm Packless Valves

More information

Variable Area Flow Meters

Variable Area Flow Meters Variable Area Flow Meters Over sixty years of variable area meter expertise Brooks started designing and manufacturing variable area (VA) meters, also referred to as rotameters, in 1946. Now, with more

More information

5k Slickline Lightweight Pressure Control Equipment 4 ID

5k Slickline Lightweight Pressure Control Equipment 4 ID 5k Slickline Lightweight Pressure Control Equipment 4 ID Table of Contents 5k Slickline Lightweight Pressure Control Equipment 4 ID... 1 Hydraulic Slickline Stuffing Box... 3 Wireline Lubricators... 4

More information

PLD 03 T A CASAPPA S.p.A.

PLD 03 T A CASAPPA S.p.A. GEAR FLOW DIVIDERS INDEX Section Page GENERAL FEATURES... 3 GENERAL DATA... 5 FLOW EQUALIZER... 6 FLOW DIVIDERS... 8 TYPICAL CIRCUITS... 10 NOTES ABOUT COMPOSITION... 12 PORTS DIMENSIONS.... 14 GROUP DIMENSIONS...

More information

2 I All-Flo Pump Co.

2 I All-Flo Pump Co. 2 I All-Flo Pump Co. 3I All-Flo Pump Co. Model Designation Matrix Pump Dimensions A B C D F H I J K L P300 18.90" 22.83" 31.50" 3.94" 15.28" 27.17" 1.57" 2.95" 15.55" 19.49" (480 mm) (580 mm) (800 mm)

More information

TRADITIONAL HIGH VIBRATION HOSE SYSTEM THE STANDARD FOR MANY AUTOMOTIVE APPLICATIONS

TRADITIONAL HIGH VIBRATION HOSE SYSTEM THE STANDARD FOR MANY AUTOMOTIVE APPLICATIONS O-Ring Face Seal Hose TRADITIONAL HIGH VIBRATION HOSE SYSTEM THE STANDARD FOR MANY AUTOMOTIVE APPLICATIONS O-Ring Face Seal METAL FORMING SOLUTIONS THE STANDARD FOR MANY AUTOMOTIVE APPLICATIONS Table of

More information

B84G - Excelon Plus Modular System General purpose filter/regulator

B84G - Excelon Plus Modular System General purpose filter/regulator > Port size: 3/8... 3/4 (ISO G/PTF) > Excelon Plus design allows in-line installation or modular installation with other Excelon Plus products > Push to lock adjusting knob with built in tamper resistant

More information

Membrane dryers. Series airfit dry G1/2. with/without patented purge air regulation. Overview Description. Characteristics Dimensions

Membrane dryers. Series airfit dry G1/2. with/without patented purge air regulation. Overview Description. Characteristics Dimensions Overview Description Membrane fitting the airfit comfort series Page Characteristics Dimensions 146 10 11 13 14 Order instructions Type overview Membrane A4P006E-October 2007 14 Membrane Characteristics

More information

ECS Protector Nitrogen Generator PGEN-30 (PGEN-30E)

ECS Protector Nitrogen Generator PGEN-30 (PGEN-30E) ECS Protector PGEN-30 (PGEN-30E) Specifications For use under U.S. Patents 8,720,591, 9,144,700 and 9,186,533 Dimensions (cabinet): 24.5 (W) x 52.5 (H) x 8.5 (D) (622mm(W) x 1,334mm(H) x 216mm(D)) Dimensions

More information

Aquarium Sealing CHALLENGES. & How to Solve Them

Aquarium Sealing CHALLENGES. & How to Solve Them 3 Aquarium Sealing CHALLENGES & How to Solve Them As any zoo, aquarium or aquaculture environment operator can attest to, the safety and wellbeing of the animals and other marine life is the highest priority

More information

SELECTION GUIDE SELECTION GUIDE. Pressure, Flow, Level & Temperature Products for Ultra-Clean Processing P R E C I S I O N S E N S O R S

SELECTION GUIDE SELECTION GUIDE. Pressure, Flow, Level & Temperature Products for Ultra-Clean Processing P R E C I S I O N S E N S O R S SELECTION GUIDE SELECTION GUIDE Pressure, Flow, Level & Temperature Products for Ultra-Clean Processing P R E C I S I O N S E N S O R S S t a i n l e s s S t e e l P r e s s u r e S w i t c h e s f o r

More information

SERVICE MANUAL MODEL BA200AA-S1 BREATHING AIR PANEL

SERVICE MANUAL MODEL BA200AA-S1 BREATHING AIR PANEL SERVICE MANUAL MODEL BA200AA-S1 BREATHING AIR PANEL WARNING: Do not attempt to operate this equipment without first reading and understanding the service manual enclosed with this device. 1/00 2 GENERAL

More information

Nitrogen Generators. PMNG Commercial Series. Section 50 Bulletin A -20

Nitrogen Generators. PMNG Commercial Series. Section 50 Bulletin A -20 Nitrogen Generators PMNG Commercial Series Section 50 Bulletin A -20 2 All nitrogen generators Whatever the problem; Pneumatech has the solution. are not created equal. Some may cost less and appear great

More information

PANACEA P200 STAINLESS STEEL USER MANUAL

PANACEA P200 STAINLESS STEEL USER MANUAL Basic Features Stainless Steel body with 1.75 outside diameter. Will fit into wells down to 2 (schedule 80). Has an internal chamber volume of 200mL. Maximum depth below ground surface of 3000ft. Other

More information

LRS(H)4 Pressure-Reducing Regulator User Manual

LRS(H)4 Pressure-Reducing Regulator User Manual LRS(H)4 Pressure-Reducing Regulator User Manual Read the complete manual before installing and using the regulator. 2 Safe Product Selection When selecting a product, the total system design must be considered

More information

BL68 - Olympian Plus, plug-in system Filter/regulators and lubricators

BL68 - Olympian Plus, plug-in system Filter/regulators and lubricators >> Port size: 3/4... /2 (ISO G/ PTF) >> Complete air processing units pre-assembled, ready to install Technical features Medium: Compressed air only Maximum operating pressure: 7 bar (246 psi) Pressure

More information

KEYSTONE. A C E C O E n v i r o n m e n t a l C o m p a n y. Bulletin 10-B

KEYSTONE. A C E C O E n v i r o n m e n t a l C o m p a n y. Bulletin 10-B KEYSTONE Filtration Solutions A C E C O E n v i r o n m e n t a l C o m p a n y Bulletin 10-B Standard Housings The 11N, 21N and 23N filter housings are tested and certified by NSF International under

More information

Schilling Robotics TITAN 4 Manipulator

Schilling Robotics TITAN 4 Manipulator PRODUCT DATASHEET SUBSEA TECHNOLOGIES Schilling Robotics TITAN 4 Manipulator We put you first. And keep you ahead. Thousands of our manipulator systems are in use worldwide every day. TITAN manipulators

More information

COMPACT TRIPLE WALL OUTLET STATION MODEL INSTALLATION AND OPERATING INSTRUCTIONS

COMPACT TRIPLE WALL OUTLET STATION MODEL INSTALLATION AND OPERATING INSTRUCTIONS COMPACT TRIPLE WALL OUTLET STATION MODEL 6255-1 INSTALLATION AND OPERATING INSTRUCTIONS To assure safe operation and conformation to local fire codes, all Porter Outlet Stations are designed to be used

More information

ACTUATORS AND INSTRUMENTS

ACTUATORS AND INSTRUMENTS ACTUATORS AND 03 ADVANCED ACTUATORS AND FOR A COMPLETE VALVE CONTROL SOLUTION Koso Kent Introl LIMITED (KKI) supplies a full range of advanced actuators and associated instrumentation to complement its

More information

CARTRIDGE FILTERS. Models: CF50, CF75, CF100, CF150,

CARTRIDGE FILTERS. Models: CF50, CF75, CF100, CF150, CARTRIDGE FILTERS Models: CF50, CF75, CF00, CF50, The installation of this product should be carried out by a qualified pool technician, following the installation instructions provided in this manual.

More information

Customer Responsibilities

Customer Responsibilities Thank you for purchasing an Agilent instrument. To get you started and to assure a successful and timely installation, please refer to this specification or set of requirements. Correct site preparation

More information

COMPAFLOW. Compressed Air. Volumetric flow. Gas. Mass flow. Steam. Net volumetric flow. Liquid

COMPAFLOW. Compressed Air. Volumetric flow. Gas. Mass flow. Steam. Net volumetric flow. Liquid Volumetric flow Compressed Air Mass flow Gas Net volumetric flow Steam Liquid Universal compact orifice flow meter combines a compact orifice flow sensor and sotiphicated converter One-piece flow sensor,

More information

THE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301

THE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301 THE HF-300 SERIES Operating and Service Manual Series includes all variants of HF-300/301 Issue A July 2015 1 TABLE OF CONTENTS 1. Description... 3 2. Installation... 3 3. Operation... 4 3.1. Spring Loaded...

More information

CONTROL VALVE TESTING

CONTROL VALVE TESTING The optimal functioning of the Control valve not only exists of sufficient body & seat tightness, but more important, the total "performance" of the valve and its controls! For an accurate and reliable

More information

NEW EDGE SERIES REGULATORS & OUTFITS

NEW EDGE SERIES REGULATORS & OUTFITS WE LISTENED. WE DELIVERED. NEW EDGE SERIES REGULATORS & OUTFITS Victor Introduces the Newest Addition to the EDGE Series: The EHP3 High Pressure Regulator. EDGE Regulators Now Include These Models EHP3

More information