PRELIMINARY PIPE STRESS ANALYSIS OF HIGH PRESSURE, HIGH TEMPERATURE EXPERIMENTAL HELIUM COOLING SYSTEM

Size: px
Start display at page:

Download "PRELIMINARY PIPE STRESS ANALYSIS OF HIGH PRESSURE, HIGH TEMPERATURE EXPERIMENTAL HELIUM COOLING SYSTEM"

Transcription

1 A.K. VERMA, B.K. YADAV, A. GANDHI, A. SARASWAT, S. VERMA, E.R. KUMAR PRELIMINARY PIPE STRESS ANALYSIS OF HIGH PRESSURE, HIGH TEMPERATURE EXPERIMENTAL HELIUM COOLING SYSTEM A.K.VERMA Institute for Plasma Research Bhat, Gandhinagar, Gujarat, India B.K. YADAV, A. GANDHI, A. SARASWAT, S. VERMA, E. R. KUMAR Institute for Plasma Research Bhat, Gandhinagar, Gujarat, India Abstract Institute for Plasma Research (IPR) is developing an Experimental Helium Cooling Loop (EHCL) as a part of R&D activities in fusion blanket technologies. EHCL is similar to the First Wall Helium Cooling System (FWHCS) of LLCB TBM and in this loop first wall mock ups up to one fourth size of blanket can be tested. The Test Section Module (TSM) of EHCL is designed to remove heat load of ~75 kw. Similar to the FWHCS, EHCL is also high-pressure high-temperature system which produces significant moments in the piping system. This leads to forces and moments in the piping support and equipment nozzles. During the earthquake, a high acceleration acts on the piping system due to this the deflection of pipes may increase the difficulty of loop operation. The paper describes the optimized loop layout of EHCL, methodology and results of pipe stress analysis. EHCL process layout is designed in a limited space (64 m 2 ). All major equipment are installed and connected through the piping and associated valves. For the protection from high energy pipes and other safety reasons, entire process area is protected by strong barricade. The pipe stress analysis is performed for sustained and occasional (earthquake) load combinations of various operating cases envisaged for TSM mock ups. The process piping code ASME B31.3 is referred for pipe stress analysis. The calculated stresses are in acceptable limit. The least available value of stress margin (about 0.29 times the allowable stress) and the corresponding displacement of 9.8 mm (x direction), mm (y direction) and mm (z direction) is observed in heater to TSM line. The obtained reaction and moment force results are needed as an input for the selection of pipe supports and location of supports. This pipe stress analysis results are used in the optimization of EHCL layout and further these inputs would be utilized in final design phase. 1. INTRODUCTION Experimental Helium Cooling Loop (EHCL) is a high-pressure high-temperature closed loop helium gas system [1]. This helium loop is similar to the FWHCS and designed mainly for testing various component mock-ups, which are cooled by high temperature and high pressure helium [2], [3]. The Test Section Module (TSM) mockups will undergo a series of mock-ups qualification tests for design and performance validations. The design of EHCL shall also allow experiments with any other high heat flux helium-cooled components that can be operated within the loop operating range. Major objectives of EHCL are to study the dynamics of the system at different operating conditions (shown in Table 1) and to understand the loop operation & control with associated safety aspects. To take care of pressure fluctuations & loss of inventory, the process loop is also equipped with Pressure and Inventory Control System (PICS). The integrated operation of process loop with PICS, and the understanding of high pressure high temperature piping behavior are essential for final development of EHCL. The paper mainly presents EHCL optimized loop layout and results of pipe stress analysis. 2. SYSTEM DESCRIPTION EHCL is designed for 10 MPa pressure, 450 C temperature and 0.4 kg/s flow rate. The selected size for the connection pipes is DN 50 schedule 80. The maximum operating pressure and temperature are 8 MPa and 400 C respectively [1]. The details of process parameters of EHCL are shown in Table 1. Table 1. Details of process parameters of EHCL Parameters Operating Design Heat load for TSM, kw Temperature at TSM, C Coolant pressure (Helium), MPa Coolant flow rate (Helium), kg/s 0.4, 0.3, 0.2,

2 IAEA-CN-123/45 EHCL loop consists of circulators, heater, recuperator, coolers, compressors, vacuum pumps, control and safety valves, associated piping, and necessary instrumentation and control systems (shown in Fig. 1 & 4). FIG. 1. Process flow diagram of EHCL The P&ID of EHCL is presented in Fig. 1.The loop consists of a hot leg and cold leg, which are connected by recuperator. In the hot leg, TSM and electrical heater are placed, while in the cold leg circulators, dust filters and coolers are placed. In the TSM outlet line, the hot helium temperature is first reduced by the recuperator and then by the cooler. This scheme enables cold leg operation in a temperature range of C and allows the components in the cold leg to operate in a lower temperature environment which simplifies the design of the components. In the cold leg between the recuperator and cooler, helium temperature range is C, while between cooler and circulator discharge line, the temperature range is C. The hot leg is designed to accommodate maximum operating temperature of 400 C and in this portion of loop helium operating temperature range is C. Maintaining low temperature helium to the suction of the helium circulator reduces circulator power requirement. In the loop, two parallel circulators, each of 0.2 kg/s mass flow rate capacity are assembled. Based on the flow rate requirements, one or both the circulators shall be operated. Before the circulators, dust filters are installed to filter the metallic dust of the system. 3. MODELLING AND METHODOLOGY EHCL plant layout is prepared with the help of CATIA V5 modelling tool [4]. 3D layout of EHCL consists of equipment arrangement, pipe routing, supports, cable tray routing, instrumentation arrangement and impulse tube routing. The EHCL lab is constructed in 324 m 2 area, which consists of process loop, control & monitoring room, panel room, storage and maintenance area. The entire process area is fenced with metallic barricade (shown in Fig. 2).

3 A.K. VERMA, B.K. YADAV, A. GANDHI, A. SARASWAT, S. VERMA, E.R. KUMAR FIG. 2. EHCL internal arrangement (Process area with protective grid) High temperature pipes are routed from the top part of the facility. The necessary flexible supports and pipe looping are also foreseen in the loop layout. The high temperature lines of EHCL are insulated with CERAWOOL [5]. Insulation covers 20% more volume of the process area, but as estimated, sufficient space is still available for maintenance activities within the process area. For the routine inspection, 0.5 m space margin is available surrounding to all major components. FIG. 3. Access for inspection in EHCL process area The Reliability, Availability, Maintainability and Inspectability (RAMI) aspects are also taken into account during EHCL layout preparation. The inspection and maintenance access is shown in Fig. 3. The optimized layout is simplified for the piping analysis as shown in Fig. 4.The coordinates of EHCL pipes are used to recreate pipe models in CAESAR II software. The data exchange tools are not utilized in order to avoid common problems such as loss of bodies from the assemblies, displacement of original positions, and modification in the graphic information [6]. 3

4 IAEA-CN-123/45 FIG. 4. Simplified EHCL model for piping analysis CAESAR II version 5.30 is used as an analysis tool and ASME B31.3 as a reference code chosen for the analysis of EHCL pipes [7]. The modelled EHCL pipes in CAESAR II software are shown in Fig.5. FIG. 5. Modelling of EHCL pipes in CAESAR II for piping analysis

5 A.K. VERMA, B.K. YADAV, A. GANDHI, A. SARASWAT, S. VERMA, E.R. KUMAR The pipe stress analysis is performed for maximum operating conditions of EHCL (refer Table 1). The analysis is performed for sustained and occasional load cases. The sustain loads are due to the pressure, temperature & dead weight while the occasional loads are the additional seismic loads (earthquake loads) on the sustained loads. The input parameters considered for the analysis are illustrated in the Table 2. Table 2. Details of input data for CAESAR II analysis CAESAR Parameters Input values Design Code ASME B31.3 Pipe material SS 316 L Pipe size DN 50 schedule 80 Hot leg Temperature values, C 25,300,350,400 Cold leg Temperature values, C 25, 80, 100 Coolant pressure values, MPa 6.0,8.0,8.5, 10.0 Pipe density, kg /m Fluid density, kg /m CERAWOOL density, kg /m Mill tolerance % 12.5 Thermal Cycles 60,000 Allowable Stress at room temperature, MPa 115 Thermal insulation thickness for hot leg pipes, mm 100 The insulation thickness is calculated for minimum heat loss, maximum efficiency and personnel protection. The insulation thickness is estimated from 3EPlus software [8].The EHCL pipes are designed in compliance with ASME B31.3 code considering various loading conditions (operational state, maintenance and standby) [9]. The load combinations for the analysis of EHCL pipes are shown in Table 3. Table 3. Load combinations of EHCL pipes Load combination Loads Max. events Normal operation (Sustained Load Case) DW+P+T 60,000 Normal operation+ SL (Occasional Load Case) DW+P+T+ Occasional 1 IPR lies in seismic zone III and the process loop is planned to be located at ground floor of EHCL lab at IPR. FRS of Gandhinagar was used to find out the induced stress in the process loop during seismic event. The considered operational states, process parameters and load combinations for the pipe stress analysis are presented in the Table 4. Table 4. Load combinations of process piping as per planned operational states Mock-ups operational States Operational States Process parameters Load Combinations Sustain Loads Occasional Case Operation State (POS) Normal Operation State P= MPa, T= C, F = kg/s L1= DW+P1 (Sustain Case) L2= DW+P2 (Sustain Case) L3= DW+T1+P1 (Operating Case) L4= DW+T2+P2 (Operating Case) L5= L3-L1 (Expansion Case) L6= L4-L2 (Expansion Case) L1+ Occasional L2+ Occasional L3+ Occasional L4+ Occasional L5+ Occasional L6+ Occasional Short Term Standby (STS) Cold Standby State RP = MPa T = C, L1= DW+P1 (Sustain Case) L2= DW+T1+P1 (Operating Case) L1+ Occasional L2+ Occasional 5

6 IAEA-CN-123/45 RF = 0.2 kg/s, Ramping Baking state RP = 1.0 MPa, Temp. = C, RF ~ 10% of F L3= DW+T2+P1 (Operating Case) L4= L2-L1 (Expansion Case) L5= L3-L1 (Expansion Case) L1= DW+P1 (Sustain Case) L2= DW+T1+P1 (Operating Case) L3= L2-L1 (Expansion Case) L3+ Occasional L4+ Occasional L5+ Occasional L1+ Occasional L2+ Occasional L3+ Occasional Long Term Maintenance (LTM) Maintenance state Ambient conditions L1= DW+P1 (Sustain Case) L1+ Occasional DW= Dead weight, P = Pressure, T = Temperature, F = Flow, RP = Reduced Pressure, RF = Reduced Flow. 4. RESULTS The major equipment of EHCL are connected with DN 50 schedule 80 pipes. The pipe material SS316 L is used for connection pipes. The temperature dependent properties of SS316 L are considered for the analysis. The summary of pipe stresses and displacements results during normal operation conditions are shown in Fig. 6. FIG. 6. Pipe stresses and displacements during normal operation condition The summary results of EHCL pipes for sustained, thermal and occasional load cases are presented in Table 5. The stress margin is calculated as margin = (1 - Stress ratio) 100. Whereas; Stress ratio = Calculated Stress / Allowable Stress. Table 5. Summary of results for pipe stresses, displacements and reaction forces Load Cases Available Stress margin % Calculated Stress % Dx, mm Displacements Dy, mm Dz, mm Fx, N Reaction Forces Fy, N Fz, N

7 A.K. VERMA, B.K. YADAV, A. GANDHI, A. SARASWAT, S. VERMA, E.R. KUMAR Sustained Load (W+P) 68.5 (1560) 31.5 (1560) (1470) (2460) (2460) 598 (1200) -318 (630) -792 (520) Thermal Load (T) 43.1 (1100) 56.9 (1100) (1680) (1470) (2460) (1380) (630) (970) Occasional Load (W+P+ Occasional) 29.4 (1470) 70.6 (1470) 9.80 (2394) (2390) (2390) 1638 (1200) 1044 (2020) 1024 (520) The highest value of stress about times of allowable stress limit is estimated for Electric heater to TSM line. The maximum displacement of 9.8 mm (x direction), mm (y direction) and mm (z direction) is also observed in the same line. The pipe displacements would be considered during the installation of mechanical supports. The obtained reaction force results would be utilized as an input for the pipe support design. The natural frequency of the integrated EHCL piping system is 4.1 Hz. The dominating natural frequencies in X, Y & Z directions are mentioned in the Table 6. Table 6. Dominating natural frequencies and mass participation factor in X, Y & Z directions Directions Natural Frequency, Hz Mass Participation factor X Y Z The parameters used for the EHCL pipe stress analysis are the maximum allowable temperature and pressure. EHCL piping qualifies to meet the code stress criteria as per the process piping code paragraphs for sustained loads, for occasional loads and for thermal expansion loads for all static and dynamic load conditions. 5. CONCLUSIONS The 3D loop layout of EHCL is modelled in CATIA V5 software. The layout also addresses clash and RAMI aspects. The piping network is used for pipe stress analysis using CAESAR II version 5.30 in accordance with process piping code ASME B31.3. In contemplation of high temperature facility, this loop is also associated with flexible looping patterns (e.g. C and S type) to avoid excess stresses in the piping network. Further, the pipe stresses are checked for sustained loads, thermal expansion loads and occasional loads at maximum operating conditions of process loop. The calculated stresses are below the allowable values for all the cases mentioned in Table 4 and sufficient margins are available in the pipes. The accepted code stress criteria verifies the integrity of piping system. The present design is to be further analyzed for whip load, fire load and other assembly loads. This analysis may lead to slight change the loop layout and accordingly the stresses would be reassessed. REFERENCES [1] B. K. Yadav, A. Gandhi, A. K. Verma, et al., Conceptual design of experimental helium cooling loop for Indian TBM R&D experiments, world academy of science, engineering and technology Int. J. Physical and Mathematical Sciences, 8 (2) (2014). [2] B.K. Yadav, A. Gandhi, A.K. Verma, et al., Helium Cooling Systems for Indian LLCB TBM, Fusion Engineering and Design, 124 (2017) [3] A.K. Verma, B.K. Yadav, A. Gandhi, E.R. Kumar, et al., Pipe stress analysis of first wall helium cooling system for conceptual design development of IN LLCB TBM, Volume 137, December 2018, Pages [4] 3D Modeling Solutions CATIA - Dassault Systèmes 7

8 IAEA-CN-123/45 [5] Ceramic fibre blankets - Morgan Thermal Ceramics ( [6] Lubomir DIMITROV, Fani Valchkova, Problems With 3d Data Exchange Between Cad Systems Using Neutral Formats, Proceedings in Manufacturing Systems, Volume 6, Issue 3, 2011 ISSN [7] CAESAR II - Pipe Stress Analysis coade [8] Pipe Insulation Calculate Thickness 3E Plus Software [9] Process Piping Code ASME B31.3

Helium Loop Karlsruhe (HELOKA) large experimental facility for the in-vessel ITER and DEMO components

Helium Loop Karlsruhe (HELOKA) large experimental facility for the in-vessel ITER and DEMO components 1 /7-12 Helium Loop Karlsruhe (HELOKA) large experimental facility for the in-vessel IER and DEMO components M. Ionescu-Bujor, B.E. Ghidersa, G. Janeschitz, X. Jin orschungszentrum Karlsruhe, Germany e-mail:

More information

Profile LFR-43 HELENA ITALY. Italian National Agency for New Technologies, Energy and Sustainable Economic Development, C.R. ENEA Brasimone, Italy

Profile LFR-43 HELENA ITALY. Italian National Agency for New Technologies, Energy and Sustainable Economic Development, C.R. ENEA Brasimone, Italy Profile LFR-43 HELENA ITALY GENERAL INFORMATION NAME OF THE FACILITY ACRONYM COOLANT(S) OF THE FACILITY LOCATION (address): OPERATOR CONTACT PERSON (name, address, institute, function, telephone, email):

More information

Start-up of the Three-shaft Closed Loop

Start-up of the Three-shaft Closed Loop Start-up of the Three-shaft Closed Loop Brayton Cycle Model of the PBMR Power Plant PG Rousseau, GP Greyvenstein & WMK van Niekerk, School of Mechanical and Materials Engineering, Potchefstroom University

More information

Preliminary Failure Mode and Effect Analysis for CH HCSB TBM

Preliminary Failure Mode and Effect Analysis for CH HCSB TBM Preliminary Failure Mode and Effect Analysis for CH HCSB TBM Presented by: Chen Zhi Contributors by HCSB TBM Safety Group, in China June 21, 2007 E-mail: chenz@swip.ac.cn Outline Introduction FMEA Main

More information

Dynamic Operation of a 4 K Pulse Tube Cryocooler with Inverter Compressors

Dynamic Operation of a 4 K Pulse Tube Cryocooler with Inverter Compressors Dynamic Operation of a 4 K Pulse Tube Cryocooler with Inverter Compressors C. Wang Cryomech, Inc. Syracuse, NY 13211 ABSTRACT This paper introduces the concept of operating a 4 K pulse tube cryocooler

More information

Customer Responsibilities

Customer Responsibilities Thank you for purchasing an Agilent instrument. To get you started and to assure a successful and timely installation, please refer to this specification or set of requirements. Correct site preparation

More information

23.1 Functions, Basic Configuration, and Interfaces

23.1 Functions, Basic Configuration, and Interfaces 23 (6.6.D) SF 6 and Other Special Gases 23.1 Functions, Basic Configuration, and Interfaces 23.1.1 Functions The primary function performed by the SF 6 and other special gases system is to provide SF 6

More information

Customer Responsibilities

Customer Responsibilities Thank you for purchasing an Agilent instrument. To get you started and to assure a successful and timely installation, please refer to this specification or set of requirements. Correct site preparation

More information

Technical Specifications of Hydrogen Isotope Handling and Recovery System

Technical Specifications of Hydrogen Isotope Handling and Recovery System SECTION - C TECHNICAL SPECIFICATIONS OF STORES AND DRAWINGS. Technical Specifications of Hydrogen Isotope Handling and Recovery System INSTITUTE FOR PLASMA RESEARCH GANDHINAGAR, GUJARAT 382428 ANNEXURE-I

More information

Oil-Lubricated Compressors for Regenerative Cryocoolers Using an Elastic Membrane

Oil-Lubricated Compressors for Regenerative Cryocoolers Using an Elastic Membrane Oil-Lubricated Compressors for Regenerative Cryocoolers Using an Elastic Membrane E.C. Luo, Z.H. Wu, G.Y. Yu, J.Y. Hu, and W. Dai Technical Institute of Physics and Chemistry Chinese Academy of Sciences

More information

UltraLo 1800 Alpha Particle Counter

UltraLo 1800 Alpha Particle Counter XIA LLC UltraLo 1800 Alpha Particle Counter Site Requirements & Planning Version: 0.4 Friday, February 15, 2013 Table of Contents I. Site Preparation Tasks... 3 A. Instrument Overview... 3 B. Installation

More information

Experimental Analysis on Vortex Tube Refrigerator Using Different Conical Valve Angles

Experimental Analysis on Vortex Tube Refrigerator Using Different Conical Valve Angles International Journal of Engineering Research and Development e-issn: 7-067X, p-issn: 7-00X, www.ijerd.com Volume 3, Issue 4 (August ), PP. 33-39 Experimental Analysis on Vortex Tube Refrigerator Using

More information

Design and Analysis of Pressure Safety Release Valve by using Finite Element Analysis

Design and Analysis of Pressure Safety Release Valve by using Finite Element Analysis Design and Analysis of Pressure Safety Release Valve by using Finite Element Analysis Mr.V.D.Rathod* 1, Prof.G.A.Kadam* 2, Mr.V. G. Patil* 3 * 1 M.E. Design (Pursuing), SKN Sinhgad Institute of Technology&

More information

HTR Systems and Components

HTR Systems and Components IAEA Course on HTR Technology Beijing, 22-26.October 2012 HTR Systems and Components Dr. Gerd Brinkmann Dieter Vanvor AREVA NP GMBH Henry-Dunant-Strasse 50 91058 Erlangen phone +49 9131 900 96840/95821

More information

OPERATION AND SIMULATION OF A THREE-SHAFT, CLOSED-LOOP, BRAYTON CYCLE MODEL OF THE PBMR POWER PLANT

OPERATION AND SIMULATION OF A THREE-SHAFT, CLOSED-LOOP, BRAYTON CYCLE MODEL OF THE PBMR POWER PLANT OPERATION AND SIMULATION OF A THREE-SHAFT, CLOSED-LOOP, BRAYTON CYCLE MODEL OF THE PBMR POWER PLANT WMK van Niekerk, PG Rousseau & GP Greyvenstein School of Mechanical and Materials Engineering Potchefstroom

More information

Serving. Petrochemicals Power Semiconductor Waste Treatment Oil & Gas Transmission Lines Bulk Gas Plants

Serving. Petrochemicals Power Semiconductor Waste Treatment Oil & Gas Transmission Lines Bulk Gas Plants Serving Petrochemicals Power Semiconductor Waste Treatment Oil & Gas Transmission Lines ulk Gas Plants Mining & Metals Pharmaceuticals Pulp & Paper Mills Sugar Mills Nuclear Desalinization Plants NOTES:

More information

RELIABILITY ASSESSMENT, STATIC AND DYNAMIC RESPONSE OF TRANSMISSION LINE TOWER: A COMPARATIVE STUDY

RELIABILITY ASSESSMENT, STATIC AND DYNAMIC RESPONSE OF TRANSMISSION LINE TOWER: A COMPARATIVE STUDY RELIABILITY ASSESSMENT, STATIC AND DYNAMIC RESPONSE OF TRANSMISSION LINE TOWER: A COMPARATIVE STUDY Yusuf Mansur Hashim M. Tech (Structural Engineering) Student, Sharda University, Greater Noida, (India)

More information

Serving. Petrochemicals Power Semiconductor Waste Treatment Oil & Gas Transmission Lines Bulk Gas Plants

Serving. Petrochemicals Power Semiconductor Waste Treatment Oil & Gas Transmission Lines Bulk Gas Plants Serving Petrochemicals Power Semiconductor Waste Treatment Oil & Gas Transmission Lines ulk Gas Plants Mining & Metals Pharmaceuticals Pulp & Paper Mills Sugar Mills Nuclear Desalinization Plants NOTES:

More information

IJSRD - International Journal for Scientific Research & Development Vol. 4, Issue 06, 2016 ISSN (online):

IJSRD - International Journal for Scientific Research & Development Vol. 4, Issue 06, 2016 ISSN (online): IJSRD - International Journal for Scientific Research & Development Vol. 4, Issue 06, 2016 ISSN (online): 2321-0613 Design Optimization and Fabrication of a Low Pressure Vessel Bhagatsinh Verma 1 Ankur

More information

University of Cincinnati

University of Cincinnati Mapping the Design Space of a Recuperated, Recompression, Precompression Supercritical Carbon Dioxide Power Cycle with Intercooling, Improved Regeneration, and Reheat Andrew Schroder Mark Turner University

More information

Customer Responsibilities

Customer Responsibilities Thank you for purchasing an Agilent instrument. To get you started and to assure a successful and timely installation, please refer to this specification or set of requirements. Correct site preparation

More information

Design, Static Structural & Model Analysis of Water Ring Vacuum Pump Impeller

Design, Static Structural & Model Analysis of Water Ring Vacuum Pump Impeller IJSRD - International Journal for Scientific Research & Development Vol. 6, Issue 03, 2018 ISSN (online): 2321-0613 Design, Static Structural & Model Analysis of Water Ring Vacuum Pump Impeller Ajay A.

More information

FUNDAMENTAL SAFETY OVERVIEW VOLUME 2: DESIGN AND SAFETY CHAPTER I: AUXILIARY SYSTEMS. A high-capacity EBA system [CSVS] [main purge]

FUNDAMENTAL SAFETY OVERVIEW VOLUME 2: DESIGN AND SAFETY CHAPTER I: AUXILIARY SYSTEMS. A high-capacity EBA system [CSVS] [main purge] PAGE : 1 / 9 5. CONTAINMENT PURGE (EBA [CSVS]) The Reactor Building purge system comprises the following: A high-capacity EBA system [CSVS] [main purge] A low-capacity EBA system [CSVS] [mini-purge] 5.1.

More information

EDEXCEL NATIONALS UNIT 6 MECHANICAL PRINCIPLES and APPLICATIONS. ASSIGNMENT No. 4

EDEXCEL NATIONALS UNIT 6 MECHANICAL PRINCIPLES and APPLICATIONS. ASSIGNMENT No. 4 EDEXCEL NATIONALS UNIT 6 MECHANICAL PRINCIPLES and APPLICATIONS ASSIGNMENT No. 4 NAME: I agree to the assessment as contained in this assignment. I confirm that the work submitted is my own work. Signature

More information

IMPROVED XENON LOADING EQUIPMENT WITH LOADING CAPACITY UP TO 1200 KG FOR ALPHABUS

IMPROVED XENON LOADING EQUIPMENT WITH LOADING CAPACITY UP TO 1200 KG FOR ALPHABUS IMPROVED XENON LOADING EQUIPMENT WITH LOADING CAPACITY UP TO 1200 KG FOR ALPHABUS Patrick BRAVAIS, Roland SALOME +, Cécile GELAS + * AIR LIQUIDE DTA + CNES Toulouse Abstract Plasmic propulsion systems

More information

Remotely-installed Hydraulic Module

Remotely-installed Hydraulic Module Remotely-installed Hydraulic Module HDM 1.1-2.2 Single or twin pump ACC-PRC001E-GB Table of Contents Application Considerations Unit sizing...4 Unit placement... 4 Minimum water volume... 4 Selection Procedure...5

More information

Best Practices for Installation of Gaseous Sample Pumps

Best Practices for Installation of Gaseous Sample Pumps Best Practices for Installation of Gaseous Sample Pumps Goal of the Gas Sample Pump Transport a clean, reliable, sample of the process gas to the analyzer, in the safest and easiest way possible, to ensure

More information

ISSN: Page 410

ISSN: Page 410 Study of Structural Stability of Globe Valve in Petroleum and Sugar Industries Anil Rathod 1, Dr. S N Kurbet 2 1 PG Student Mechanical branch (machine Design) BEC Bagalkot, Karnataka India, 2 HOD of Mechanical

More information

Figure 1 The LHC cryogenic islands and plants layout

Figure 1 The LHC cryogenic islands and plants layout The LHC cryogenic operation for first collisions and physics run Brodzinski K, Barth K, Benda V, Bremer J, Casas-Cubillos J, Claudet S, Delikaris D, Ferlin G, Fernandez Penacoba G, Perin A, Pirotte O,

More information

Overflow valves Type OFV REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Overflow valves Type OFV REFRIGERATION AND AIR CONDITIONING. Technical leaflet Overflow valves Type OFV 20-25 REFRIGERATION AND AIR CONDITIONING Technical leaflet Contents Page Introduction....................................................................................... 3 Features...........................................................................................

More information

Oxford Instruments Plasma Technology. PlasmaPro NGP80. Installation Data Sheet. Original Instructions.

Oxford Instruments Plasma Technology. PlasmaPro NGP80. Installation Data Sheet. Original Instructions. Oxford Instruments Plasma Technology www.oxford-instruments.com About this data sheet This data sheet provides basic information about the installation of a tool. Floor and wall loadings Table 1 lists

More information

OPTIMIZATION OF SINGLE STAGE AXIAL FLOW COMPRESSOR FOR DIFFERENT ROTATIONAL SPEED USING CFD

OPTIMIZATION OF SINGLE STAGE AXIAL FLOW COMPRESSOR FOR DIFFERENT ROTATIONAL SPEED USING CFD http:// OPTIMIZATION OF SINGLE STAGE AXIAL FLOW COMPRESSOR FOR DIFFERENT ROTATIONAL SPEED USING CFD Anand Kumar S malipatil 1, Anantharaja M.H 2 1,2 Department of Thermal Power Engineering, VTU-RO Gulbarga,

More information

Step 1: Step 2: psi psi

Step 1: Step 2: psi psi General Tutorial on Evaluation of Nozzles by computing Local Shell Stresses as per WRC 537 and Stress Evaluation as per ASME Section VIII Division 2 using CAEPIPE Whenever Pressure Vessel or Heat exchanger

More information

Experimental Verification of Integrated Pressure Suppression Systems in Fusion Reactors at In-Vessel Loss-of -Coolant Events

Experimental Verification of Integrated Pressure Suppression Systems in Fusion Reactors at In-Vessel Loss-of -Coolant Events Experimental Verification of Integrated Pressure Suppression Systems in Fusion Reactors at In-Vessel Loss-of -Coolant Events K. Takase 1), H. Akimoto 1) 1) Japan Atomic Energy Research Institute (JAERI),

More information

Cooling Characteristics of GM-type Pulse Tube Refrigerator with Neon as Working Gas

Cooling Characteristics of GM-type Pulse Tube Refrigerator with Neon as Working Gas Cooling Characteristics of GM-type Pulse Tube Refrigerator with Neon as Working Gas J. Ko, Y.J. Hong, H. Kim, H. Yeom, S.J. Park, D.Y. Koh Korea Institute of Machinery & Materials Daejeon, Korea (S), 305-343

More information

Overflow valves Type OFV Type OFV-SS REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Overflow valves Type OFV Type OFV-SS REFRIGERATION AND AIR CONDITIONING. Technical leaflet Overflow valves Type OFV 20-25 Type OFV-SS 20-25 REFRIGERATION AND AIR CONDITIONING Technical leaflet Contents Page Introduction.......................................................................................

More information

ECONORESS ELECTRONIC EPS & EPT - ENHANCED PRESSURISATION SET INSTALLATION OPERATION & MAINTENANCE DOCUMENTATION

ECONORESS ELECTRONIC EPS & EPT - ENHANCED PRESSURISATION SET INSTALLATION OPERATION & MAINTENANCE DOCUMENTATION ECONORESS ELECTRONIC EPS & EPT - ENHANCED PRESSURISATION SET INSTALLATION OPERATION & MAINTENANCE DOCUMENTATION OCT2010 STOKVIS ENERGY SYSTEMS 96R WALTON ROAD EAST MOLESEY SURREY KT8 0DL TEL: 020 87833050

More information

Earlier Lecture. In the earlier lecture, we have seen Kapitza & Heylandt systems which are the modifications of the Claude System.

Earlier Lecture. In the earlier lecture, we have seen Kapitza & Heylandt systems which are the modifications of the Claude System. 17 1 Earlier Lecture In the earlier lecture, we have seen Kapitza & Heylandt systems which are the modifications of the Claude System. Collins system is an extension of the Claude system to reach lower

More information

International Journal of Advance Engineering and Research Development DESIGN CALCULATIONS TO EVALUATE PERFORMANCE PARAMETERS OF COMPRESSOR VALVE

International Journal of Advance Engineering and Research Development DESIGN CALCULATIONS TO EVALUATE PERFORMANCE PARAMETERS OF COMPRESSOR VALVE Scientific Journal of Impact Factor (SJIF): 4.72 International Journal of Advance Engineering and Research Development Volume 4, Issue 7, July -2017 e-issn (O): 2348-4470 p-issn (P): 2348-6406 DESIGN CALCULATIONS

More information

SAMSON SOLUTIONS Energy and Power (Critical Applications)

SAMSON SOLUTIONS Energy and Power (Critical Applications) SAMSON SOLUTIONS Energy and Power (Critical Applications) Speakers: Ing. Gianluigi Rossi Ing. Stefano Salvadori Managing Director - SAMSON Italy Head of Sales and Project Department - SAMSON Italy MARKET

More information

1 SE/P-02. Experimental and Analytical Studies on Thermal-Hydraulic Performance of a Vacuum Vessel Pressure Suppression System in ITER

1 SE/P-02. Experimental and Analytical Studies on Thermal-Hydraulic Performance of a Vacuum Vessel Pressure Suppression System in ITER 1 SE/P-2 Experimental and Analytical Studies on Thermal-Hydraulic Performance of a Vacuum Vessel Pressure Suppression System in ITER K. Takase 1), H. Akimoto 1) 1) Japan Atomic Energy Research Institute,

More information

RICK FAUSEL, BUSINESS DEVELOPMENT ENGINEER TURBOMACHINERY CONTROL SYSTEM DESIGN OBJECTIVES

RICK FAUSEL, BUSINESS DEVELOPMENT ENGINEER TURBOMACHINERY CONTROL SYSTEM DESIGN OBJECTIVES RICK FAUL, BUSINESS DEVELOPMENT ENGINEER TURBOMACHINERY CONTROL SYSTEM DESIGN OBJECTIVES The primary design objective for any turbomachinery control system should be to maintain or maximize machine and

More information

Two-way Fluid Structure Interaction (FSI) Analysis on the Suction Valve Dynamics of a Hermetic Reciprocating Compressor

Two-way Fluid Structure Interaction (FSI) Analysis on the Suction Valve Dynamics of a Hermetic Reciprocating Compressor Volume 118 No. 18 2018, 4241-4252 ISSN: 1311-8080 (printed version); ISSN: 1314-3395 (on-line version) url: http://www.ijpam.eu ijpam.eu Two-way Fluid Structure Interaction (FSI) Analysis on the Suction

More information

Pressure regulating valves Types OFV, OFV-SS

Pressure regulating valves Types OFV, OFV-SS Data sheet Pressure regulating valves Types OFV, OFV-SS OFV are angle-way pressure regulating valves, which have ajustable opening pressure and cover the differential pressure range ( P): 2-8 bar (29 116

More information

PVP Copyright 2009 by ASME

PVP Copyright 2009 by ASME Proceedings of PVP 009 009 ASME Pressure Vessel and Piping Division Conference July 6-30, 009, Prague, Czech Republic PVP009-7746 UPDATE OF THE TABULATED «M AND Y» VALUES IN THE NEW REVISIONS OF FRENCH

More information

Influencing Factors Study of the Variable Speed Scroll Compressor with EVI Technology

Influencing Factors Study of the Variable Speed Scroll Compressor with EVI Technology Purdue University Purdue e-pubs International Compressor Engineering Conference School of Mechanical Engineering 2016 Influencing Factors Study of the Variable Speed Scroll Compressor with EVI Technology

More information

NORMAL OPERATING PROCEDURES Operating Parameter Information

NORMAL OPERATING PROCEDURES Operating Parameter Information Operating Parameter Information Each operator performing the normal operating procedures (routine checks) of the facility should be familiar with the current normal operating parameters of all systems

More information

Control & Maintenance. INT69 Diagnose INT69 TM Diagnose. Protect the heart of your system

Control & Maintenance. INT69 Diagnose INT69 TM Diagnose. Protect the heart of your system Control & Maintenance INT69 Diagnose INT69 TM Diagnose Protect the heart of your system R INT69 DIAGNOSE The widely known protective system INT69 and INT69 TM present on all Frascold compressors is now

More information

AN EVALUATION OF ENCAPSULATED OIL FLOODED SCREW COMPRESSOR SYSTEMS. Nikola Stosic, Ahmed Kovacevic, ian K Smith and Elvedin Mujic

AN EVALUATION OF ENCAPSULATED OIL FLOODED SCREW COMPRESSOR SYSTEMS. Nikola Stosic, Ahmed Kovacevic, ian K Smith and Elvedin Mujic Proceedings of IMECE2007 2007 ASME International Mechanical Engineering Congress and Exposition November 11-15, 2007, Seattle, Washington, USA IMECE2007-43027 AN EVALUATION OF ENCAPSULATED OIL FLOODED

More information

University of Cincinnati

University of Cincinnati Mapping the Design Space of a Recuperated, Recompression, Precompression Supercritical Carbon Dioxide Power Cycle with Intercooling, Improved Regeneration, and Reheat Andrew Schroder Mark Turner University

More information

[Barve, 4(7): July, 2015] ISSN: (I2OR), Publication Impact Factor: 3.785

[Barve, 4(7): July, 2015] ISSN: (I2OR), Publication Impact Factor: 3.785 IJESRT INTERNATIONAL JOURNAL OF ENGINEERING SCIENCES & RESEARCH TECHNOLOGY PARAMETRIC STUDY TO UNDERSTAND THE SEISMIC BEHAVIOUR OF INTZE TANK SUPPORTED ON SHAFT Prasad S. Barve *, Ruchi P. Barve * Civil

More information

International Journal of Technical Research and Applications e-issn: , Volume 4, Issue 3 (May-June, 2016), PP.

International Journal of Technical Research and Applications e-issn: ,  Volume 4, Issue 3 (May-June, 2016), PP. DESIGN AND ANALYSIS OF FEED CHECK VALVE AS CONTROL VALVE USING CFD SOFTWARE R.Nikhil M.Tech Student Industrial & Production Engineering National Institute of Engineering Mysuru, Karnataka, India -570008

More information

Improving distillation tower operation

Improving distillation tower operation Improving distillation tower operation Measuring differential pressure across long sections of distillation columns has always been challenging, but purpose-built sensor systems provide a solution Fast

More information

ADVANCES in NATURAL and APPLIED SCIENCES

ADVANCES in NATURAL and APPLIED SCIENCES ADVANCES in NATURAL and APPLIED SCIENCES ISSN: 1995-0772 Published BYAENSI Publication EISSN: 1998-1090 http://www.aensiweb.com/anas 2017 June 11(8): pages 408-415 Open Access Journal Design of Absorptive

More information

Development of High Efficiency 4K Two-Stage Pulse Tube Cryocooler

Development of High Efficiency 4K Two-Stage Pulse Tube Cryocooler Development of High Efficiency 4K Two-Stage Pulse Tube Cryocooler M. Xu, H. Takayama and K. Nakano Sumitomo Heavy Industries, Ltd. Nishi-tokyo-city, Tokyo, Japan 188-8585 ABSTRACT Sumitomo Heavy Industries

More information

First Experimental Data of the Cryogenic Safety Test Facility PICARD

First Experimental Data of the Cryogenic Safety Test Facility PICARD First Experimental Data of the Cryogenic Safety Test Facility PICARD C. Heidt, A. Henriques, M. Stamm and S. Grohmann 26 th International Cryogenic Engineering Conference 2016 in New Delhi, India KIT,

More information

Efficiency Improvement of Rotary Compressor by Improving the Discharge path through Simulation

Efficiency Improvement of Rotary Compressor by Improving the Discharge path through Simulation Purdue University Purdue e-pubs International Compressor Engineering Conference School of Mechanical Engineering 2014 Efficiency Improvement of Rotary Compressor by Improving the Discharge path through

More information

Gas Vapor Injection on Refrigerant Cycle Using Piston Technology

Gas Vapor Injection on Refrigerant Cycle Using Piston Technology Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2012 Gas Vapor Injection on Refrigerant Cycle Using Piston Technology Sophie

More information

Pressure Systems Safety Regulation

Pressure Systems Safety Regulation Pressure Systems Safety Regulation Introduction This document informs Faculty of the key requirements of the UK and Chinese Pressure Systems Safety regulations. The aim of these regulations is to prevent

More information

An Investigative and Synoptic Review on Helium Liquefaction Using a Commercial 4 K Gifford- McMahon Cryocooler

An Investigative and Synoptic Review on Helium Liquefaction Using a Commercial 4 K Gifford- McMahon Cryocooler An Investigative and Synoptic Review on Helium Liquefaction Using a Commercial 4 K Gifford- McMahon Cryocooler Mahesh N 1, S A Mohan Krishna 2 1 PG Student, Vidyavardhaka College of Engineering, Mysore,

More information

ASERCOM guidelines for the design of multiple compressor racks using frequency inverters

ASERCOM guidelines for the design of multiple compressor racks using frequency inverters ASERCOM guidelines for the design of multiple compressor racks using frequency inverters Contents 1 SCOPE AND PURPOSE 2 SELECTION OF COMPRESSORS 3 DESIGN FEATURES 4 CONTROL FEATURES 5 STABILITY OF WORKING

More information

S-CO 2 Brayton Recompression Loop Design and Control

S-CO 2 Brayton Recompression Loop Design and Control S-CO 2 Brayton Recompression Loop Design and Control 1) Background 2) Recommended Design Features 3) Modeling Strategy IST Model Changes Transient Results Prepared by: Mike Hexemer Advanced Concepts Knolls

More information

Flexible Metal Hose Products

Flexible Metal Hose Products Flexible Metal Hose Products Specialty Flexible Hose Solutions of Stainless Steel The AEROCOM Advantage Aerocom offers engineered solutions that address specific flexible piping challenges such as vibration,

More information

E 328 E 498 Tank top mounting Connection up to G1½ / -24 SAE and SAE 2 Nominal flow rate up to 600 l/min / gpm

E 328 E 498 Tank top mounting Connection up to G1½ / -24 SAE and SAE 2 Nominal flow rate up to 600 l/min / gpm Return-Suction Filters E 8 E 98 Tank top mounting Connection up to G½ / - SE and SE Nominal flow rate up to 6 l/min / 8. gpm Description pplication For operation in units with hydrostatic drives, when

More information

Developments on Flow Rate And High Pressure Stability of Peroxide Dosing Pumps For The Chemical Industry

Developments on Flow Rate And High Pressure Stability of Peroxide Dosing Pumps For The Chemical Industry Developments on Flow Rate And High Pressure Stability of Peroxide Dosing Pumps For The Chemical Industry Franz Trieb, Reinhard Karl, Rene Moderer Bohler Hochdrucktechnik GmbH Kapfenberg, Austria www.bhdt.at

More information

Low GWP R-404A Alternatives for Commercial Refrigeration. Barbara H. Minor Dr. Frank Rinne DuPont Fluorochemicals

Low GWP R-404A Alternatives for Commercial Refrigeration. Barbara H. Minor Dr. Frank Rinne DuPont Fluorochemicals Low GWP R-404A Alternatives for Commercial Refrigeration Barbara H. Minor Dr. Frank Rinne DuPont Fluorochemicals Chillventa Nűrnberg October 9-11, 2012 Topics Regulatory Environment Properties of New Refrigerants

More information

E 328 E 498 Tank top mounting Connection up to G1½ and SAE 2 Nominal flow rate up to 600 l/min

E 328 E 498 Tank top mounting Connection up to G1½ and SAE 2 Nominal flow rate up to 600 l/min Return-Suction Filters E 8 E 98 Tank top mounting Connection up to G½ and SE Nominal flow rate up to 6 l/min Description pplication For operation in units with hydrostatic drives, when the return flow

More information

LP Separator Level Control by Variable Speed and Multi Stage Brine Reinjection Pumps at Kawerau and Nga Awa Purua Geothermal Projects, New Zealand

LP Separator Level Control by Variable Speed and Multi Stage Brine Reinjection Pumps at Kawerau and Nga Awa Purua Geothermal Projects, New Zealand Proceedings World Geothermal Congress 2010 Bali, Indonesia, 25-29 April 2010 LP Separator Level Control by Variable Speed and Multi Stage Brine Reinjection Pumps at Kawerau and Nga Awa Purua Geothermal

More information

S265 Remote seals with capillary tube. 2600T Series Pressure Transmitters. Engineered solutions for all applications

S265 Remote seals with capillary tube. 2600T Series Pressure Transmitters. Engineered solutions for all applications Contents Data Sheet S265 2600T Series Pressure Transmitters Engineered solutions for all applications Wide range of remote seal types Allows optimum design for each application without compromising performance

More information

Research of Variable Volume and Gas Injection DC Inverter Air Conditioning Compressor

Research of Variable Volume and Gas Injection DC Inverter Air Conditioning Compressor Purdue University Purdue e-pubs International Compressor Engineering Conference School of Mechanical Engineering 2016 Research of Variable Volume and Gas Inection DC Inverter Air Conditioning Compressor

More information

Cable in Conduit Conductor (CICC) quench modelling

Cable in Conduit Conductor (CICC) quench modelling DEMO SAMPLE Cable in Conduit Conductor (CICC) quench modelling This demo gives an example of quench simulation for a Central Solenoid (CS). CS is divided into geometrically identical sections (see Fig.

More information

DESIGN AND THERMAL-HYDRAULIC PERFORMANCE OF A HELIUM COOLED TARGET FOR THE PRODUCTION OF MEDICAL ISOTOPE 99M TC

DESIGN AND THERMAL-HYDRAULIC PERFORMANCE OF A HELIUM COOLED TARGET FOR THE PRODUCTION OF MEDICAL ISOTOPE 99M TC DESIGN AND THERMAL-HYDRAULIC PERFORMANCE OF A HELIUM COOLED TARGET FOR THE PRODUCTION OF MEDICAL ISOTOPE 99M TC Keith Woloshun, Gregory E. Dale, Charles T. Kelsey IV, Eric R. Olivas, Michael A. Holloway,

More information

Linear Compressor Suction Valve Optimization

Linear Compressor Suction Valve Optimization Purdue University Purdue e-pubs International Compressor Engineering Conference School of Mechanical Engineering 2016 Linear Compressor Suction Valve Optimization Rinaldo Puff Embraco, Brazil, rinaldo.puff@embraco.com

More information

Fitness for Service Assessment of Ageing Pressure Vessel Experiencing External Corrosion: A Case Study

Fitness for Service Assessment of Ageing Pressure Vessel Experiencing External Corrosion: A Case Study The International Journal Of Engineering And Science (IJES) Volume 6 Issue 2 Pages PP 12-16 2017 ISSN (e): 2319 1813 ISSN (p): 2319 1805 Fitness for Service Assessment of Ageing Pressure Vessel Experiencing

More information

Products for Cryogenic Applications

Products for Cryogenic Applications Products for Cryogenic Applications Cryogenic valves, self-operated regulators, differential pressure meters SMART IN FLOW CONTROL. Designed for cryogenic service Industry, medicine, supply engineering

More information

Information Sheet. About this information sheet. Floor and wall loadings. Attachment of process module to floor. PlasmaPro Estrelas100

Information Sheet. About this information sheet. Floor and wall loadings. Attachment of process module to floor. PlasmaPro Estrelas100 Information Sheet PlasmaPro Estrelas100 About this information sheet This data sheet provides basic information about the installation of a PlasmaPro Estrelas100 tool. Some of the information in this sheet

More information

Design. Pompetravaini-NSB API SB Liquid Ring Compressor for Gas Processing. Working Principle

Design. Pompetravaini-NSB API SB Liquid Ring Compressor for Gas Processing. Working Principle SB Pompetravaini-NSB API SB Liquid Ring Compressor for Gas Processing A family of API liquid ring compressors has been developed and has been in the market for nearly a decade, they are specifically made

More information

Customer Responsibilities. Important Customer Information. Cary 4000/5000/6000i UV-Vis spectrophotometer Site Preparation Checklist

Customer Responsibilities. Important Customer Information. Cary 4000/5000/6000i UV-Vis spectrophotometer Site Preparation Checklist Thank you for purchasing an Agilent instrument. To get you started and to assure a successful and timely installation, please refer to this specification or set of requirements. Correct site preparation

More information

Liquid Lead-Bismuth Materials Test Loop

Liquid Lead-Bismuth Materials Test Loop Liquid Lead-Bismuth Materials Test Loop Valentina Tcharnotskaia, Curtt Ammerman, Timothy Darling, Joe King, Ning Li, Don Shaw, Leon Snodgrass, Keith Woloshun. Los Alamos National Laboratory, P.O. Box 1663,

More information

Inspection Credit for PWSCC Mitigation via Peening Surface Stress Improvement

Inspection Credit for PWSCC Mitigation via Peening Surface Stress Improvement Inspection Credit for PWSCC Mitigation via Peening Surface Stress Improvement Glenn A. White, Kyle P. Schmitt, Kevin J. Fuhr, Markus Burkardt, and Jeffrey A. Gorman Dominion Engineering, Inc. Paul Crooker

More information

FUNDAMENTAL SAFETY OVERVIEW VOLUME 2: DESIGN AND SAFETY CHAPTER F: CONTAINMENT AND SAFEGUARD SYSTEMS 7. CONTAINMENT HEAT REMOVAL SYSTEM (EVU [CHRS])

FUNDAMENTAL SAFETY OVERVIEW VOLUME 2: DESIGN AND SAFETY CHAPTER F: CONTAINMENT AND SAFEGUARD SYSTEMS 7. CONTAINMENT HEAT REMOVAL SYSTEM (EVU [CHRS]) PAGE : 1 / 16 7. CONTAINMENT HEAT REMOVAL SYSTEM (EVU [CHRS]) 7.0. SAFETY REQUIREMENTS 7.0.1. Safety functions The main functions of the EVU system [CHRS] are to limit the pressure inside the containment

More information

44 (0) E:

44 (0) E: FluidFlow Relief Valve Sizing Handbook Flite Software 2016 Flite Software N.I. Ltd, Block E, Balliniska Business Park, Springtown Rd, Derry, BT48 0LY, N. Ireland. T: 44 (0) 2871 279227 E: sales@fluidflowinfo.com

More information

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units Models: EPS Single Pump EPT Twin Pump EPS-HP EPT-HP Single Pump High Pressure Twin Pump High Pressure

More information

Recirculating Coolers

Recirculating Coolers (Chillers) - Basic type Low Temp. - General Type Low Temp. - Intelligent type Selection Guide Recirculating Cooler Basic type General type (Low temp.) Intelligent type (Low temp.) Working Temp. Range (

More information

2600T Series Pressure Transmitters Plugged Impulse Line Detection Diagnostic. Pressure Measurement Engineered solutions for all applications

2600T Series Pressure Transmitters Plugged Impulse Line Detection Diagnostic. Pressure Measurement Engineered solutions for all applications Application Description AG/266PILD-EN Rev. C 2600T Series Pressure Transmitters Plugged Impulse Line Detection Diagnostic Pressure Measurement Engineered solutions for all applications Increase plant productivity

More information

Two-stage pulse tube refrigerator with step displacer as phase shifter

Two-stage pulse tube refrigerator with step displacer as phase shifter IOP Conference Series: Materials Science and Engineering PAPER OPEN ACCESS Two-stage pulse tube refrigerator with step displacer as phase shifter To cite this article: Shaowei Zhu 2015 IOP Conf. Ser.:

More information

PERFORMANCE AND CHARACTERISTICS OF COMPRESSOR/EXPANDER COMBINATION FOR CO 2 CYCLE ABSTRACT

PERFORMANCE AND CHARACTERISTICS OF COMPRESSOR/EXPANDER COMBINATION FOR CO 2 CYCLE ABSTRACT PERFORMANCE AND CHARACTERISTICS OF COMPRESSOR/EXPANDER COMBINATION FOR CO 2 CYCLE M. FUKUTA, T. YANAGISAWA, S. NAKAYA (b), and Y. OGI Shizuoka University, 3-5-1 Johoku Hamamatsu, 432-8561, Japan Fax +81-53-478-158,

More information

Liquid ring compressors

Liquid ring compressors Liquid ring compressors KPH 95652 Compression pressures: 6 to 12 bar(g) Suction volume flow: 2960 to 3600 m³/h 78 to 174 psig 1742 to 2119 cfm DESIGN TYPE SIHI liquid ring compressors are displacement

More information

Identification and Screening of Scenarios for LOPA. Ken First Dow Chemical Company Midland, MI

Identification and Screening of Scenarios for LOPA. Ken First Dow Chemical Company Midland, MI Identification and Screening of Scenarios for LOPA Ken First Dow Chemical Company Midland, MI 1 Layers of Protection Analysis (LOPA) LOPA is a semi-quantitative tool for analyzing and assessing risk. The

More information

Application of Computational Fluid Dynamics to Compressor Efficiency Improvement

Application of Computational Fluid Dynamics to Compressor Efficiency Improvement Purdue University Purdue e-pubs International Compressor Engineering Conference School of Mechanical Engineering 1994 Application of Computational Fluid Dynamics to Compressor Efficiency Improvement J.

More information

Selection of ICF made easy Save even more time with ICF

Selection of ICF made easy Save even more time with ICF MAKING MODERN LIVING POSSIBLE Selection of ICF made easy Save even more time with ICF ICF stands for valve trains and for over five years installation and service has never been easier. This quick guide

More information

HumiSys HF High Flow RH Generator

HumiSys HF High Flow RH Generator HumiSys HF High Flow RH Generator Designed, built, and supported by InstruQuest Inc. Versatile Relative Humidity Generation and Multi-Sensor System The HumiSys HF is a high flow version of the previously

More information

Operational Behaviour of Safety Valves with Constant Superimposed Backpressure

Operational Behaviour of Safety Valves with Constant Superimposed Backpressure Operational Behaviour of Safety Valves with Constant Superimposed Backpressure Arne Gastberg Albert Richter ARI-Armaturen GmbH & Co. KG When selecting spring loaded safety valves, an accurate knowledge

More information

WP2 Fire test for toxicity of fire effluents

WP2 Fire test for toxicity of fire effluents Pagina 3 di 89 TRA SFEU VTT 22.6.2009 v.2 WP2 Fire test for toxicity of fire effluents Task 2.1.2 Development of small-scale test method for fire effluents Step 1: Use of modeling Plans according to DoW:

More information

CNS In-Pool Assembly Mechanical Design for OYSTER Project

CNS In-Pool Assembly Mechanical Design for OYSTER Project CNS In-Pool Assembly Mechanical Design for OYSTER Project JINBOK CHOI, JUNGHYUN RYU Korea Atomic Energy Research Institute (KAERI) 111 Deadeok-daero 989Beon-gil, Yuseong-gu, Daejeon, Republic of Korea

More information

CONTAINMENT OF CO2 REFRIGERATION INSTALLATIONS

CONTAINMENT OF CO2 REFRIGERATION INSTALLATIONS CONTAINMENT OF CO2 REFRIGERATION INSTALLATIONS X. CAZAURAN, S. GUYOT, C. HERMON CETIM, Centre Technique des Industries Mécaniques, 74 route de la Jonelière, 44326 Nantes, France Fax : +33 ()251 86 73,

More information

Design and optimization of a low pressure vessel

Design and optimization of a low pressure vessel Abstract Research Journal of Engineering Sciences ISSN 2278 9472 Design and optimization of a low pressure vessel Available online at: www.isca.in, www.isca.me Received 8 th April 2017, revised 11 th July

More information

Schedule of Requirements THERMODYNAMICS LABORATORY- CHEMICAL ENGINEERING DEPARTMENT

Schedule of Requirements THERMODYNAMICS LABORATORY- CHEMICAL ENGINEERING DEPARTMENT S. No 1 Description Calorimeter The Unit should be designed for the accurate determination of the calorific value of liquid and solid hydrocarbons and other fuels. Specifications: A temperature-controlled

More information

Hazard Operability Analysis

Hazard Operability Analysis Hazard Operability Analysis Politecnico di Milano Dipartimento di Energia HAZOP Qualitative Deductive (search for causes) Inductive (consequence analysis) AIM: Identification of possible process anomalies

More information

SALT RSS-NIR MID-TERM REVIEW MAY 20 & 21, 2009 THERMAL SYSTEM DESIGN

SALT RSS-NIR MID-TERM REVIEW MAY 20 & 21, 2009 THERMAL SYSTEM DESIGN SALT RSS-NIR MID-TERM REVIEW MAY 20 & 21, 2009 THERMAL SYSTEM DESIGN DOUG ADLER UNIVERSITY OF WISCONSIN NIR THERMAL SYSTEMS Three primary thermal systems: Predewar, Dewar, and Electronics NIR instrument

More information