Prestige Water Equipment Ltd.
|
|
- Godwin Perry
- 5 years ago
- Views:
Transcription
1 The Prestige range of water softeners complements the range of water pre-treatment products and services. Use of water softening minimises the problems caused by hard water scale such as reduced heat transfer and pipe work blockages. The models 350 to 1300 provide a maximum flow rate range of 14 to 42m 3 /hour. Regeneration Control for simplex models is via either timer (T) or meter (M) control. Features and Benefits Microprocessor Electronic Controls Quality materials of construction to maximise plant life. 24V operation for safety. Safety Brine Valve to prevent salt tank overflow. Full range of ancillary equipment available for a packaged installation. Equipment, Service and all Water Treatment Equipment needs covered from one point of contact. Minimal control interfaces for straightforward ease of installation. Local and remote status indication available to achieve accountability at all times.
2 SPECIFICATION The following items shall be supplied as part of each duplex softener. Pressure Vessel One seamless pressure vessel complete with support skirt constructed from composite material. Regeneration Control Valve One five cycle mechanically operated regeneration control valve fabricated from corrosion resistant bronze with 560CD rubber seals and `O' rings and PTFE coated pistons. Complete with microprocessor electronic control timing and staging motors, an integrated injector, drain line flow controller and integral water meter (on W versions only). Ion Exchange Resin An appropriate quantity of potable quality ion exchange resin. Regeneration Equipment One HDPE salt storage tank complete with brine well, safety brine valve, brine line flow controller and suction line. Electrical Supply: A mains isolator, fused at 5 amps, must be provided to the unit supplying either 110V or 240V, single phase 50Hz AC. A transformer provides 24V to softener control valve and solenoid valve, if fitted. Volt free contacts are available for remote monitoring and control of optional service valve isolator. Water Quality Test Set One test set to ascertain hardness content of treated water. Instructions One set of installation and operating instructions. INSTALLATION The range of softeners is designed with ease of installation in mind. To that end installation of the units should normally be straightforward if the following points are adhered to. Alternatively, PWE can provide a full installation service for all the water treatment plant. Pressure The inlet water pressure to the unit must be between 1.8 and 8.5 bar at all times i.e. service and regeneration.
3 If the minimum pressure cannot be guaranteed, the performance of the softener unit will be impaired and, in particular, the regeneration process will almost certainly not operate efficiently leading to a malfunctioning of the softening procedure. Consideration should also be given to the pressure available at the outlet from the softener, to ensure that this is sufficient to deliver the required duty to service. If low pressure is likely to adversely affect the performance of the softening equipment, a break tank and booster set should be installed. If the maximum pressure is exceeded, damage is likely to occur to the softening equipment. In these circumstances, pressure-reducing equipment should be installed. PWE can supply suitable equipment to overcome any such pressure problems. Positioning The units are free standing and require a solid, level base capable of supporting the full working weight. Ensure the maximum recommended access dimensions are available and consider the salt re-fill requirement. Salt is normally supplied in 25kg bags. Particular attention must be paid to ensuring that there is a suitable drain, local to the softener, capable of taking the maximum flow from the unit during a regeneration period. Pipe work The installer should run pipe work and drains to and from the softener as detailed in the enclosed schematics. Plastic or copper pipe is preferable. Galvanised pipe should be avoided.
4 F 1415 G 1415 A C J 2.7 m E D H A B BRINE TANK Model 350 B Dimensions (mm) A Overall height B Overall width Softener vessel diameter C Height of salt and brine measure tanks * Diameter of salt and brine measure tanks * D Drain connection ¾ ¾ ¾ E Brine draw connection ½ ½ ½ F Overall depth G Front access requirement H Side access requirement J Height to inlet & outlet connection Inlet Connection BSP Female Outlet Connection BSP Female Salt tank overflow connection ½ hose connector Minimum headroom requirement 500
5 n.b. * twin tanks or separate bulk salt saturators are recommended for 1000 litre softener and above due to the large quantities of salt used per regeneration. Softener Range Performance Data 350, 500,700, 800, 1000 & 1300 litre Capacity Cold Water Simplex Units Model Resin Volume (litres) Valve Type Maximum Service Flow (m 3 /hr) Minimum Service Flow (m 3 /hr) Capacity (grams) Maximum Operating Pressure (bar) Minimum Operating Pressure (bar) Pressure 100% Flow (bar) Pressure 50% Flow (bar) Regeneration Volume to Drain (m 3 ) Regeneration Time (minutes) Salt Used/Regeneration (kg) Salting Level (grams/litre) Maximum Operating Temperature ( o C) Inlet/outlet Connections - BSPM Working Weight (kg) Shipping Weight (kg) NOTES: 1. Volume of water between regenerations (m 3 ) = Capacity (grams)/raw Water Hardness (as ppm CaCO3). 2. Drain Capacity should be 110% of Regeneration Flow. 3. Weights are approximate (excludes salt storage weight)
Prestige Water Equipment Ltd.
The Prestige range of water softeners complements the range of water pretreatment products and services. Use of water softening minimises the problems caused by hard water scale such as reduced heat transfer
More informationInstallation Operation Maintenance Manual
Installation Operation Maintenance Manual Duplex Water Softeners With WS1, 1.5 & 2 Series Valve Models 20 ltr - 750 ltr 1.0 PARTS LIST... 3 1.1 BASIC PARTS LIST... 3 1.2 MISSING OR DAMAGED GOODS... 3 2.0
More informationInstallation Operation Maintenance Manual
Installation Operation Maintenance Manual Simplex Water Softeners With WS1, 1.5 & 2 Series Valve Models 20 ltr - 750 ltr SIMPWS1 REV3 13/07/11 PAGE 1 OF27 1.0 PARTS LIST...3 1.1 BASIC PARTS LIST...3 1.2
More informationInstallation Operation Maintenance Manual
2910 & 3900 DX 2050 Series Installation Operation Maintenance Manual Duplex Softener (Simplex Option) With 2910 & 3900 Series Downflow Brining Valve 150-1250 litres Resin Cold Water & Hot Water Versions
More informationInstructions for SILEX 1C Mixed bed cartridge filter
D01B-30A-UK1 January 2017 Instructions for SILEX 1C Mixed bed cartridge filter With conductivity sensor Gravity flow or pressure installation SILHORKO-EUROWATER A/S Phone +45 86 57 12 22 DK-8660 Skanderborg
More informationInstallation Operation Maintenance Manual
9000/9100/9500 Duplex Series Installation Operation Maintenance Manual Duplex Softener With 9000/9100/9500 Series Downflow Brining Valve 20-350 litres Resin Inc. Measuring Tank Option Models: Mechanical
More informationThe ultimate in water softening
Calming troubled waters Metered Water Softener Specification MODEL: CALSOFT M The ultimate in water softening Due to Calmag s commitment to new product development the photographs contained within these
More informationDuplex Commercial Softeners
Duplex Commercial Softeners Installation, Operation & Maintenance Guide Manual 003.1 Contents Page 1. Unpacking Instructions 3 2. Installation 4 Pre-installation checks Fitting the bottom distribution
More informationMONARCH WATER: ASSEMBLY AND INSTALLATION INSTRUCTIONS EDC Models Simplex Water Softeners Effective January 2014.
MONARCH WATER: ASSEMBLY AND INSTALLATION INSTRUCTIONS EDC Models Simplex Water Softeners Effective January 2014. Please read these instructions carefully before the assembly and installation of your water
More informationInstallation Operation Maintenance Manual
5600SE Series Installation Operation Maintenance Manual Cabinet Water Softener With 5600SE Series Valve Models 4 lit 7 lit 10 lit 14 lit 20 lit 25 lit 30 lit Rev 2.0 01/01/06 CONTENTS NOS. PAGE 1.0 GENERAL
More informationInstallation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units
Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units Models: EPS Single Pump EPT Twin Pump EPS-HP EPT-HP Single Pump High Pressure Twin Pump High Pressure
More informationCommercial Softeners. Installation, Operation & Maintenance Guide. Manual 002.1
Commercial Softeners Installation, Operation & Maintenance Guide Manual 002.1 Contents Page 1. Unpacking Instructions 3 2. Installation 3 Pre-installation checks Fitting the bottom distribution system
More informationInstallation Operation Maintenance Manual
5600SE Simplex Series Installation Operation Maintenance Manual Simplex Softener With 5600SE Series Downflow Brining Valve Models 10 lit 14 lit 20 lit 25 lit 30 lit 40 lit 50 lit 60 lit 75 lit Rev 0 01/03/05
More informationO&M Receiving and Inspection. Storage of Water Treatment Media
O&M 105.1 Receiving and Inspection 1. Equipment should be checked against the Bill of Lading to verify that the number of pieces received matches those shipped. 2. Equipment should be carefully inspected
More informationSXT NITRATE Simplex Series Installation Operation Maintenance Manual. Installation Operation Maintenance Manual
Installation Operation Maintenance Manual Simplex Nitrate Removal With 5600, 2750, 280, 2910SXT Valve Series Models 10 lit 14 lit 20 lit 25 lit 30 lit 40 lit 50 lit 60 lit 75 lit 100 lit 150 lit 250 lit
More informationECONORESS ELECTRONIC EPS & EPT - ENHANCED PRESSURISATION SET INSTALLATION OPERATION & MAINTENANCE DOCUMENTATION
ECONORESS ELECTRONIC EPS & EPT - ENHANCED PRESSURISATION SET INSTALLATION OPERATION & MAINTENANCE DOCUMENTATION OCT2010 STOKVIS ENERGY SYSTEMS 96R WALTON ROAD EAST MOLESEY SURREY KT8 0DL TEL: 020 87833050
More informationUSE AND MAINTENANCE MANUAL V260
USE AND MAINTENANCE MANUAL V260 S.A.T.I.A. srl Società Italiana apparecchiatura trattamento acqua MAN0034 BOZZA Pag. 1 di 21 DOCUMENT REVISION REVISION NOTE DATE MAN0034 DRAFT S.A.T.I.A. srl Società Italiana
More informationTechnical Topics. Softener Elution Studies TT
Technical Topics TT-035-1204 Water softeners are critical components in many commercial and industrial water-using systems. By removing calcium and magnesium ions (hardness) from a facility s or system
More informationUSE AND MAINTENANCE MANUAL V360
USE AND MAINTENANCE MANUAL V360 S.I.A.T.A. S.r.l Società Italiana apparecchiature trattamento acqua MAN0031 BOZZA Pag. 1 of Document Revision Revision note Date MAN0031 A Draft S.I.A.T.A. S.r.l Società
More informationInstallation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units
Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units Micro-S / Micro-S Digital Wall Hung Unit Please fulfil all listed requirements prior to and during
More informationINSTRUCTION MANUAL. Demineralizer. 24R Two Stage Deioniser. Brand :
INSTRUCTION MANUAL Demineralizer Model : 24R Two Stage Deioniser Brand : 24R Two Stage Deioniser Operating Instructions 24R Two Stage Deionisers Page 1 IMPORTANT It is most important that this instruction
More informationV230 VALVE OPERATING MANUAL
V230 VALVE OPERATING MANUAL S.I.A.T.A. srl Società Italiana apparecchiature trattamento acqua MAN0021 Rev. B Pag 1 di 27 DOCUMENT REVISION REVISION NOTES DATE MAN0029 A BOZZA 19/06/98 MAN0029 B EMISSIONE
More informationV230 VALVE OPERATING MANUAL
V230 VALVE OPERATING MANUAL S.I.A.T.A. srl Società Italiana apparecchiature trattamento acqua MAN0021 Rev. B Pag 1 di 24 DOCUMENT REVISION REVISION NOTES DATE MAN0029 A BOZZA 19/06/98 MAN0029 B EMISSIONE
More informationDRS4-RM Manual. Set Up Instructions for DRS4 Series Single Tank
Set Up Instructions for DRS4 Series Single Tank Inspect the packaging of the equipment to confirm that nothing was damaged during shipping. (Figure 1) Remove the resin tank(s) and valve(s) from the packaging.
More informationThe Compact, Portable, Efficient and Economical Solution to boost Shop Compressed Air Pressure by 2 or 3 times
Tseries Series AB AB Air Air Boosters Boosters The Compact, Portable, Efficient and Economical Solution to boost Shop Compressed Air Pressure by 2 or 3 times.01/1 MANIFOLD MOUNTED VALVES FOR EASY SERVICING
More informationPressVal Pressurisation Units. Packaged Pressurisation Units with expansion vessels for heating systems.
PressVal Packaged with expansion s for heating systems. lamco Basepak LEXILLER lamco Basepak LEXILLER POWER AULT MUTE/ RESET SYSTEM OK lamco ON / O lamco Basepak LEXILLER PressVal SM skid mounted units
More informationGROUTEC SCOTT VICKERS. Grouting Equipment
GROUTEC SCOTT VICKERS Grouting Equipment SCOTT VICKERS manufacturers a range of cement and chemical grouting equipment including:- PUMPS - The Cement Grout Pumps are all diaphragm-type. These diaphragms,
More informationTECHNICAL ACCESSORIES
A.R.I. VALVES S-050P AIR PLASTIC RELEASE 16 BAR Automatic Component A.R.I patent, Rolling Seal Mechanism: Dramatically reduces the possibility of obstruction by debris. Discharges high air flow rates upto
More informationInstallation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units Digital Range
Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units Digital Range Models: DS 126 Single Pump / Single System DT 126 Twin Pump / Single System DS 160
More informationSOFTENER D-DF & D-UF Series
Water conditioning System. SOFTENER D-DF & D-UF Series INSTRUCTION MANUAL, OPERATION & MAINTENANCE 1. - PRESENTATION. In this manual, what is described are the required actions for the instalment, start
More informationEasy Nest Kits. Installation Suggestions
Easy Nest Kits Installation Suggestions 2 General Recommendations Hydraulics Vacuum breakers should be installed to prevent siphoning. Flexible connectors should follow FRP tank manufacturers recommendations.
More informationSofteners Clack Model V125DTH Medical / Industrial Series Operation and Service Manual
Softeners Clack Model V125DTH Medical / Industrial Series Operation and Service Manual www.ameriwater.com 800-535-5585 AmeriWater LLC 3345 Stop 8 Rd. Dayton, OH 45414 Clack Softener Manual, 98-0180 Rev.
More informationSystem Pressure Manager Standard & System Pressure Manager Plus
System Pressure Manager Standard & System Pressure Manager Plus Installation, Commissioning & Servicing Instructions Note: THESE INSTRUCTIONS MUST BE READ AND UNDERSTOOD BEFORE INSTALLING, COMMISSIONING,
More informationNORMAL OPERATING DISPLAYS GENERAL OPERATION
SunTapWat e rsys t e ms WS1Cl ac kwat e rsof t ne r Owne r smanual MAIN COMPONENTS Your water treatment system is a point of entry (POE) system composed of three components: A. The control valve and computer
More informationINSTRUCTION MANUAL. Automatic Water Softener System. Model: PSE-08. Xsential Water Filtration Systems
INSTRUCTION MANUAL Automatic Water Softener System Model: PSE-08 Xsential Water Filtration Systems 78 Daly Street Ascot Western Australia 6104 Ph: 1300 366 295 Fax: (08) 9277 2266 www.xsential.com.au Welcome
More informationElectronic Single and Twin Pump System Pressure Managers
Electronic Single and Twin Pump System Pressure Managers Installation, Commissioning & Servicing Instructions Note: THESE INSTRUCTIONS MUST BE READ AND UNDERSTOOD BEFORE INSTALLING, COMMISSIONING, OPERATING
More informationLiquid ring vacuum pumps in compact design
Liquid ring vacuum pumps in compact design, Pressure range: Suction volume flow: 33 to 113 mbar 3 to 58 m³/h CONSTRUCTION TYPE SIHI liquid ring vacuum pumps are displacement pumps of uncomplicated and
More informationPerforma Cv Twin Alternating and High Flow Systems. Manual Supplement
Performa Cv Twin Alternating and High Flow Systems Manual Supplement Table of Contents 1.0 Installation and Start-Up.............. 3 Water Line Connection Brine Tank Turbine Connection Connecting Manifold
More informationmikrofill PRESSURISATION UNIT
IN SPIR E D PRESSURISATION E F F I CI E NCY UNIT MIKR O F IL L 3 P R E SSUR I SAT I O N U NI T mikrofill PRESSURISATION UNIT INTRODUCTION Renowned for developing innovative products, Mikrofill has built
More informationGENO -Flushing Compressor Product Data Sheet F 02
GENO -flushing compressor 1988 K Fig. 1: GENO -flushing compressor 1988 K Designated application is suitable for the following fields of application: Flushing of pipes with water/air mix prior to the start-up
More informationWITH PUMPMASTER 3+3 PUMPS - 20 AND 50 Kg.
MOBILE GREASE UNITS WITH PUMPMASTER 3+3 PUMPS - AND Kg. 01 AIR OPERATED OIL PUMPS AND KITS Iquip modit iriuscidunt nos niam ver ip AIR OPERATED PISTON PUMPS FOR OIL AND LUBRICANTS............... 000...
More informationWATER SOFTENER. Instructions Manual Use and Maintenance
WATER SOFTENER Instructions Manual Use and Maintenance Thank you for purchasing the H+WS WATER SOFTENER from HYDROCARE... Thanks to the water softener, your water system, heating system, boiler as well
More informationWatMan WATER RO SYSTEMS FOR DESALINATION
WatMan WATER RO SYSTEMS FOR DESALINATION The WatMan reverse osmosis systems produce from 1 to 2000 m 3 per day of high quality water suitable for communities, marine environment, boiler feed and general
More informationLiquid ring vacuum pumps in compact design
Liquid ring vacuum pumps in compact design LEM 25, LEM 5 Pressure range: Suction volume flow: 33 to 113 mbar 4 to 6 m³/h CONSTRUCTION SIHI liquid ring vacuum pumps are displacement pumps of uncomplicated
More informationAIR-SAVER G1 AIR-SAVER G2 LOCATOR-EV COMPRESSED AIR CONDENSATE MANAGEMENT AND ENERGY SAVING PRODUCTS AIR SAVING PRODUCTS
AIR-SAVER G1 AIR-SAVER G2 LOCATOR-EV ENVIRONMENT ADDING VALUE SAFEGUARD RELIABLE COMPRESSED AIR CONDENSATE MANAGEMENT AND ENERGY SAVING PRODUCTS AIR SAVING PRODUCTS Air saving products INDEX Chapter Content
More informationVACUUM REGULATORS CONTENTS
CAD drawing data catalog is available. ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS CONTENTS Small Regulators Features 759 Specifications, Order Codes, Flow Rate
More informationKSB Delta Compact Type Series Booklet
Pressure Booster System KSB Delta Compact Type Series Booklet Legal information/copyright Type Series Booklet KSB Delta Compact All rights reserved. The contents provided herein must neither be distributed,
More informationAQUAMATIC EASY NEST KITS INSTALLATION SUGGESTIONS
AQUAMATIC EASY NEST KITS INSTALLATION SUGGESTIONS TABLE OF CONTENTS TABLE OF CONTENTS...2 GENERAL RECOMMENDATIONS...2 TROUBLESHOOTING GUIDE...3 EXISTING EASY NEST SYSTEM TROUBLESHOOTING GUIDE...4 COMPONENT
More informationScrew Compressors 11-22kW
INDUSTRIALS GROUP Screw Compressors 11-22kW KSA Plus Fixed Speed, KSV Variable Speed Smart and affordable CHAMPION COMPRESSED AIR TECHNOLOGIES KSA Plus Screw Compressors Up to 45 C ambient temperature
More informationINSTALLATION & START-UP INSTRUCTIONS. Clack WS1 & WS1.25 METER WATER SOFTENER SYSTEMS
INSTALLATION & START-UP INSTRUCTIONS Clack WS1 & WS1.25 METER WATER SOFTENER SYSTEMS 1999-2009 QualityWaterForLess.com - 1 - info@qualitywaterforless.com Preface: Thank you for your purchase of a new Water
More informationInstallation, Operation and Maintenance Instructions for Mild Steel Buffer Vessel
OM006 Installation, Operation and Maintenance Instructions for Mild Steel Buffer Vessel The operating and maintenance instructions contained within this package are for standard mild steel buffer vessels
More informationES 2070 SV. Electronic controller for water softening units. Instruction Manual. Software version 1.00
ES 2070 SV Electronic controller for water softening units Instruction Manual Software version 1.00 CONTENTS System Description... 1 Illustration... 2 Status and Regeneration.... 3 Messages... 3 LED -
More informationInnovDos Foam proportioning system
InnovDos Lorrie 9 NL - 1724 BL Oudkarspel T: +31 88 9112 112 F: +31 88 9112 119 info@innovfoam.com www.innovfoam.com 1 1. General Information System Composition The InnovDos is made up of two main components
More informationTECHNICAL DATA. Trimpac 244a. September 16, 2013
September 16, 2013 Trimpac 244a 1. DEsCrIpTION DESCRIPTION TRIMPAC Model B-1 and B-1B is a factory-assembled trim package with an electric release module in a metal enclosure. The standard trim normally
More informationInnoVfoam B.V. InnovDos Foam Proportioning System
1724 BL Oudkarspel F. +31 (0)88 9112 119 info@innovfoam.com 1 1. GENERAL INFORMATION SYSTEM COMPOSITION The InnovDos system is made up of two main components (see flow schedule on page 4) that can be integrated
More informationAccessories for Sanitary Installations
5. Accessories for Sanitary Installations Flamco s Prescor B safety valves protect potable water systems from exceeding the maximum design operating pressure. Once the set pressure has been reached the
More informationINSTALLATION & START-UP INSTRUCTIONS FLECK 9100SXT METER TWIN ALTERNATING WATER SOFTENER SYSTEMS
INSTALLATION & START-UP INSTRUCTIONS FLECK 9100SXT METER TWIN ALTERNATING WATER SOFTENER SYSTEMS 1999-2007 QualityWaterForLess.com - 1 - info@qualitywaterforless.com Preface: Thank you for your purchase
More informationAirless-spraying equipment. SuperFinish 23. Solid. Profitable. Innovative QLS technology
Airless-spraying equipment SuperFinish 23 Solid Profitable Innovative QLS technology The easily transported Airless spraying equipment for flexible use on the building site Innovative QLS technology reliable
More informationDS MZ, MZF, MJF THREE-PORT SEAT VALVES
DS 4.610 11/99, F, THREE-PORT SEAT VALVES Specification No. 626-3-XXX These seat valves are of 'globe' construction with a linear moving spindle and a modified parabolic characterised plug operating against
More informationTECHNICAL DATA. Trimpac 251a. Spetember 16, 2013
Spetember 16, 2013 Trimpac 251a 1. DEsCrIpTION DESCRIPTION TRIMPAC Model B-6 and B-6B is a factory assembled trim package for a double interlocked preaction system with an electric/pneu-lectric release
More informationKSB Delta Compact Type Series Booklet
Pressure Booster System KSB Delta Compact Type Series Booklet Legal information/copyright Type Series Booklet KSB Delta Compact All rights reserved. The contents provided herein must neither be distributed,
More informationTECHNICAL DATA. Trimpac 257a. September 16, 2013
September 16, 2013 Trimpac 257a 1. DESCrIpTION DESCRIPTION The Viking Double SUREFIRE SIngle Interlock Preaction TRIMPAC Model D-2 and D-2B used with either a Model E or F Deluge Valve (A.1), a Viking
More informationCAT Course Trust Your Water
CAT Course Trust Your Water Introduction Kinetico features and softened water benefits Cocurrent and countercurrent regeneration Check the correct installation Field Analysis Installation instructions
More informationCO 2 radial piston compressor (transcritical)
CO 2 radial piston compressor (transcritical) At a glance Operating limits and performance data Technical data Dimensions and connections Scope of supply 124 126 129 130 131 Radial piston compressor (transcritical)
More informationManual Actuated Boiler Blowdown Valves
Manual Actuated Boiler Blowdown Valves Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4. Operation 5. Maintenance 6. Spare parts p.1 1. Safety
More information1 Exam Prep NSF/ANSI Tabs and Highlights
1 Exam Prep NSF/ANSI 50 2015 Tabs and Highlights These 1 Exam Prep Tabs are based on ANSI/NSF 50-2015, Equipment for Swimming Pools, Spas, Hot Tubs and Other Recreational Water Facilities. Each 1 Exam
More informationPOP Safety Valve. POP Safety Valve INTRODUCTION DEFINITIONS
POP Safety Valve POP Safety Valve INTRODUCTION The effects of exceeding safe pressure levels in an unprotected pressure vessel or system, can have catastrophic effects on both plant and personnel. Safety
More informationSelf-supporting hot water high pressure cleaner on trailer Hudson 315
Self-supporting hot water high pressure cleaner on trailer Hudson 315 High pressure system mounted in a Waterkracht single-axle trailer, with flip top. The trailer is made of stainless steel top and galvanised
More informationBREATHERS VC Series. The best-selling traditional breather type, with mechanical valve.
BREATHERS VC Series The best-selling traditional breather type, with mechanical valve www.cedaspe.com AIR DEHYDRATING BREATHERS threaded and/or flanged connection, with mechanical valve type VCP 10 30
More informationMFP14-PPU (Vented) Automatic Packaged Pump Units
681060/2 IM-P681-02 ST Issue 2 MFP14-PPU (ented) Automatic Packaged Pump Units Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Single MFP14 - PPU installation
More informationWater Solenoids Safety Valves Air. Meters. Butterfly Ball Gate Globe Strainers Pressure Gauges Thermometers
Water Solenoids Safety Valves Air Valves Meters Butterfly Ball Gate Globe Strainers Pressure Gauges Thermometers Pneumatics Steam Traps Fire Hydrants Boiler Valves Water Metering Systems By combining high
More informationwater purification cylinders & accessories
water purification cylinders & accessories The exchange cylinder concept If you require purified water with low expenditure, then the SUEZ Cylinder Exchange Service is for you. Simply purchase the required
More informationAUTOMATIC SOFTENERS SERIES: AM/DT AM/RDT AM/DV AM/RDV AM/D METER AM/RD METER INSTRUCTIONS MANUAL WARNING!
AUTOMATIC SOFTENERS SERIES: AM/DT AM/RDT AM/DV AM/RDV AM/D METER AM/RD METER INSTRUCTIONS MANUAL WARNING! The equipment must be used only for the utilization for which they have been designed, as shown
More informationInstallation and Instructions 2. Product Features 3-6. Key Pad Functions 7. Distributor Information Programming Guide 8. Master Programming Guide 9-14
Installation and Instructions 2 Product Features 3-6 Key Pad Functions 7 Distributor Information Programming Guide 8 Master Programming Guide 9-14 Dimensional Drawing 15 D-STC & D-SMM Valve Assembly 16-17
More informationBIMBAR INFLATABLE PACKERS AND ACCESSORIES
BIMBAR INFLATABLE PACKERS AND ACCESSORIES Geopro supplies a complete range of inflatable packers in nine different diameters from 28 up to 170mm. All our packers made of BIMBAR rubber technology are reinforced
More informationMZX. Three-Port Seat Valves SPECIFICIATIONS AND GUIDE TO SELECTION
01 These seat valves are of globe construction with a linear moving spindle and a modified parabolic characterised plug operating against the upper seat which controls flow quantity to suit the load. The
More informationOwner s Manual. R&M Water Group TM. Models: SA-TECH PLUS 40 DB SA-TECH PLUS 48 DB
TM Owner s Manual Models: SA-TECH PLUS 40 DB SA-TECH PLUS 48 DB R&M Water Group TM Water Conditioning & Purification Systems A Division of Water Technologies, Inc. 28 South 1550 West, Lindon, Utah 84042
More informationSpectraPure PUMPED RO SYSTEMS (PSP) User s Manual for PSP-1500 Systems
SpectraPure PUMPED RO SYSTEMS (PSP) User s Manual for PSP-1500 Systems 2 3 PSP-1500 SYSTEM DESCRIPTION Reverse Osmosis RO Reverse Osmosis utilizes the unique properties of a semi-permeable membrane to
More informationOIL SUPPLY SYSTEMS ABOVE 45kW OUTPUT 4.1 Oil Supply
OIL SUPPLY SYSTEMS ABOVE 45kW OUTPUT 4.1 Oil Supply 4.1.1 General The primary function of a system for handling fuel oil is to transfer oil from the storage tank to the oil burner at specified conditions
More informationmulti-boost the EPS range of multi-boost water systems Owners Manual Installation Operation Maintenance demand special treatment
multi-boost the EPS range of multi-boost water systems Owners Manual Installation Operation Maintenance demand special treatment Table of Contents Introduction... Health & Safety Health. Safety. Designs
More informationOPTIPOW 105 OPTIPOW 105 ; MAIN PARTS. Our Ref: PSE, Bernt Andersson
Page 1 (6) Our Ref: PSE, Bernt Andersson OPTIPOW 105 OPTIPOW 105, the compact pulse valve for the Optipulse fabric filters of different types: is a result of many years of experiences within the fabric
More informationCAST IRON SAFETY VALVE TYPE 6301
CHARACTERISTICS The 6301 safety valve is dedicated to protect the equipment from potential overpressure. This is an automatic device that closes when the pressure conditions are back to normal. It is a
More informationTECHNICAL DATA. TRIMPAC Model B-5 & B-5B
September 16, 2013 Trimpac 250a 1. DESCRIPTION DEsCRIPTIoN is a factory assembled trim package for a ed an electric/pneumatic release module in a metal enclosure. The standard trim normally required on
More informationAirfix. Flamco. Flamco. Pressure expansion vessels for sanitary appliances and potable water systems AIRFIX A AIRFIX D AIRFIX D-E
AIRFIX EXPANSION VESSELS Flamco Airfix Pressure expansion vessels for sanitary appliances and potable water systems AIRFIX A AIRFIX AIRFIX -E Flamco Edition 2005 / EXP Flamco Flamco offers you a wide choice
More informationMAGNA-CHEM AUTOMATIC CHLORINATOR - MODEL: CSA-2P MAGNA ORP Chlorine Pump
A. PARTS MAGNA-CHEM AUTOMATIC CHLORINATOR - MODEL: CSA-2P MAGNA ORP Chlorine Pump Assembly & Operating Instructions Parts for liquid chlorine pump head 1pc. 1/4 poly delivery tubing, 4 meters 1pc. drum
More informationTECHNICAL DATA. Trimpac 256a. October 31, 2013
October 31, 2013 Trimpac 256a 1. DESCRIPTION The Viking SUREFIRE SIngle Interlock Preaction TRIMPAC Model D-1 and D- 1B used with either a Model E or F Deluge Valve (A.1), a Viking Easy Riser check valve
More informationINSTRUCTION MANUAL FOR. Chlorinator M 3600 C Controlmatik ABW
INSTRUCTION MANUAL FOR Chlorinator M 3600 C 2014 Controlmatik ABW 1 CONTENTS 1. General... 3 2. Operation... 4 2.1 Automatic control... 6 2.2 Manual control - 1... 6 2.3 Manual control - 2... 6 3. Motor
More informationIAPMO GUIDE CRITERIA FOR BALL VALVES IAPMO IGC PURPOSE
INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS IAPMO GUIDE CRITERIA FOR BALL VALVES IAPMO IGC 157-20067 1 PURPOSE 1.1 The purpose of this standard is to establish an acceptable standard
More informationPressure reducing valves Index
Index General information page Introduction 506 General introduction 507 for a steam plant 509 Product information BSP thread page Brass 510 ; BSP female thread 511 ; BSP male thread 513 Stainless steel
More informationInstallation of Ballast Water Management Systems
(Sept 2015) (Rev.1 May 2016) Installation of Ballast Water Management Systems 1. Application In addition to the requirements contained in BWM Convention (2004), the following requirements are applied to
More informationTHE COMPACT LINE. Mobile power packs in convincing BAUER quality l/min 225 / 330 bar TOUGH RELIABLE WELL ESTABLISHED
THE COMPACT LINE Mobile power packs in convincing BAUER quality 100 140 l/min 225 / 330 bar TOUGH RELIABLE WELL ESTABLISHED COMPACT LINE mobile breathing air compressors for high demands Due to its legendary
More informationWater make-up systems & water treatment technology
Water make-up systems & water treatment technology Fillcontrol, Fillset, Fillsoft We are only satisfied if you are Refle has set itself the goal of supporting you with well thought-out solutions. Whatever
More informationHose Reel Unit, OMM. Discipline: TECHNIC Configuration control: X. Rev. Purpose Date Prep. Check. Appr. Changeorder No.
OPERATION AND MAINTENANCE MANUAL Doc.No.: Hose Reel Unit, OMM Discipline: TECHNIC Configuration control: X Yes No Access: KOS Rev. Purpose Date Prep. Check. Appr. Changeorder No. 02 AS BUILT 111298 ID
More informationIntroduction Advantages of cooperating with Our service - our conditions Our standard central control valve
Introduction Advantages of cooperating with Our service - our conditions Our standard central control valve Gravel-Filter Deferrisation Systems Pressure filter EKF, made of stainless steel (V4A) Pressureless
More informationMASS TRANSFER LAB. Make & Model. S. No. Equipment
MASS TRANSFER LAB S. No. Equipment Make & Model Manufacture Qty 1 Liquid / Liquid Extraction Unit UOP5-A Armfield 1 2 Gas Liquid Absorption UOP7-A Armfield 1 3 Diffusion of a Liquid Apparatus CER A-A Armfield
More informationSTAINLESS STEEL GRAND SERIES
STAINLE STEEL GRAND SERIES STAINLE STEEL GRAND SERIES DEEPWELL SUBMERSIBLE PUMPS STAINLE STEEL - GRAND SERIES C.R.I. Always equips itself in advance to face the exponentially growing technological challenges
More information265 Series Valve Operation Manual
265 Series Valve Operation Manual Note: 1. Read all instructions carefully before operation. 2. Avoid pinched o-rings during installation by applying (provided with install kit) NSF certified lubricant
More informationSummary of the MRA LPG Codes of Practice
Summary of the MRA LPG Codes of Practice COP A1 DESIGN and INSTALLATION Code COP A1 deals with above ground installations where LPG is stored under pressure at ambient temperatures in fixed vessels larger
More informationPortable Dosing Unit
Portable Dosing Unit The purpose of this project is to provide trailer mounted portable hypochlorite dosing units that can be used on Melbourne Water mains where mains pressures are less than 100 MWG or
More informationOperating Instructions Model and Hydrostatic Test Pump
Operating Instructions Model 39300 and 39301 Hydrostatic Test Pump Dimension Weight Pump Style Capacity Pressure Motor Lubrication Control Gauge Inlet Connection Outlet Connection Discharge Hose Hose Ends
More information