P800/PX800. Advanced Series PLASTIC Pumps. Advance your process. Engineering Operation & Maintenance WIL E-04 TO REPLACE WIL E-03

Size: px
Start display at page:

Download "P800/PX800. Advanced Series PLASTIC Pumps. Advance your process. Engineering Operation & Maintenance WIL E-04 TO REPLACE WIL E-03"

Transcription

1 P800/PX800 Advanced Series PLASTIC Pumps Engineering Operation & Maintenance Advance your process WIL E-04 TO REPLACE WIL E-03

2 TABLE OF CONTENTS SECTION 1 CAUTIONS READ FIRST! SECTION 2 WILDEN PUMP DESIGNATION SYSTEM SECTION 3 HOW IT WORKS PUMP & AIR DISTRIBUTION SYSTEM SECTION 4 DIMENSIONAL DRAWINGS SECTION 5 PERFORMANCE A. P800 Performance Curves Rubber-Fitted TPE-Fitted Reduced Stroke PTFE-Fitted Full Stroke-Fitted Ultra-Flex -Fitted Suction Lift Curve B. PX800 Performance Curves Operating Principal How to Use this EMS Curve Performance Curves Rubber-Fitted TPE-Fitted Reduced Stroke PTFE-Fitted Full Stroke-Fitted Ultra-Flex -Fitted Suction Lift Curve SECTION 6 SUGGESTED INSTALLATION, OPERATION & TROUBLESHOOTING SECTION 7 DISASSEMBLY/REASSEMBLY Pump Disassembly Pro-Flo Air Valve / Center Section Disassembly Pro-Flo X TM Air Valve / Center Section Disassembly Reassembly Hints & Tips SECTION 8 EXPLODED VIEW & PARTS LISTING P800 PLASTIC P800 Full Stroke-Fitted P800 Reduced Stroke-Fitted P800 PLASTIC PX800 Full Stroke-Fitted PX800 Reduced Stroke-Fitted SECTION 9 ELASTOMER OPTIONS

3 Section 1 CAUTIONS READ FIRST! CAUTION: Do not apply compressed air to the exhaust port pump will not function. CAUTION: Do not over-lubricate air supply excess lubrication will reduce pump performance. Pump is pre-lubed. TEMPERATURE LIMITS: Neoprene 17.7 C to 93.3 C 0 F to 200 F Buna-N 12.2 C to 82.2 C 10 F to 180 F EPDM 51.1 C to C 60 F to 280 F Viton 40 C to C 40 F to 350 F Saniflex 28.9 C to C 20 F to 220 F Polytetrafluoroethylene (PTFE) 4.4 C to C 40 F to 220 F Polyurethane 12.2 C to 65.6 C 10 F to 150 F Tetra-Flex PTFE w/neoprene Backed 4.4 C to C 40 F to 225 F Tetra-Flex PTFE w/epdm Backed -10 C to 137 C 14 F to 280 F Wil-Flex -40 C to C (-40 F to 225 F) NOTE: Not all materials are available for all models. Refer to Section 2 for material options for your pump. CAUTION: When choosing pump materials, be sure to check the temperature limits for all wetted components. Example: Viton has a maximum limit of C (350 F) but polypropylene has a maximum limit of only 79 C (175 F). CAUTION: Maximum temperature limits are based upon mechanical stress only. Certain chemicals will significantly reduce maximum safe operating temperatures. Consult Chemical Resistance Guide (E4) for chemical compatibility and temperature limits. WARNING: Prevention of static sparking If static sparking occurs, fire or explosion could result. CAUTION: Always wear safety glasses when operating pump. If diaphragm rupture occurs, material being pumped may be forced out air exhaust. CAUTION: Before any maintenance or repair is attempted, the compressed air line to the pump should be disconnected and all air pressure allowed to bleed from pump. Disconnect all intake, discharge and air lines. Drain the pump by turning it upside down and allowing any fluid to flow into a suitable container. CAUTION: Blow out air line for 10 to 20 seconds before attaching to pump to make sure all pipeline debris is clear. Use an in-line air filter. A 5µ (micron) air filter is recommended. CAUTION: If the pipe plug in the inlet or discharge manifold on the 51 mm (2") Advanced plastic center-ported model is removed, a triple density (red) PTFE pipe tape is recommended to ensure adequate sealing. NOTE: When installing PTFE diaphragms, it is important to tighten outer pistons simultaneously (turning in opposite directions) to ensure tight fit. (See torque specifications in Section 7.) NOTE: Before starting disassembly, mark a line from each liquid chamber to its corresponding air chamber. This line will assist in proper alignment during reassembly. CAUTION: Pro-Flo pumps cannot be used in submersible applications. Pro-Flo X is available in both submersible and non-submersible options. Do not use non-submersible Pro-Flo X models in submersible applications. CAUTION: Tighten all hardware prior to installation. CAUTION: Do not exceed 8.6 bar (125 psig) air supply pressure. CAUTION: The process fluid and cleaning fluids must be chemically compatible with all wetted pump components. Consult Chemical Resistance Guide (E4). CAUTION: Do not exceed 82 C (180 F) air inlet temperature for Pro-Flo X models. WIL E-04 1 WILDEN PUMP & ENGINEERING, LLC

4 Section 2 WILDEN PUMP DESIGNATION SYSTEM P800/PX800 PLASTIC 51 mm (2") Pump Maximum Flow Rate: 693 lpm (183 gpm) LEGEND PX800 / XXXXX / XXX / XX / XXX / XXXX MODEL O-RINGS VALVE SEAT VALVE BALLS DIAPHRAGMS AIR VALVE CENTER BLOCK AIR CHAMBERS WETTED PARTS & OUTER PISTON SPECIALTY CODE (if applicable) MATERIAL CODES MODEL P800 = PRO-FLO PX800 = PRO-FLO X WETTED PARTS KK = PVDF / PVDF PK = POLYPROPYLENE / PVDF AIR CHAMBERS P = POLYPROPYLENE CENTER BLOCK P = POLYPROPYLENE AIR VALVE P = POLYPROPYLENE L = ACETAL (P800 only) DIAPHRAGMS BNS = BUNA-N (Red Dot) BNU = BUNA-N, ULTRA-FLEX EPS = EPDM (Blue Dot) EPU = EPDM, ULTRA-FLEX FSS = SANIFLEX [Hytrel (Cream)] NES = NEOPRENE (Green Dot) NEU = NEOPRENE, ULTRA-FLEX PUS = POLYURETHANE (Clear) TEU = PTFE W/EPDM BACK-UP (White) TNU = PTFE W/NEOPRENE BACK-UP (White) TSU = PTFE W/SANIFLEX BACK-UP (White) VTS = VITON (White Dot) VTU = VITON, ULTRA-FLEX WFS = WIL-FLEX [Santoprene (Orange Dot)] TSS = FULL STROKE PTFE W/SANIFLEX BACK-UP TWS = FULL STROKE PTFE W/WIL-FLEX BACK-UP VALVE BALL BN = BUNA-N (Red Dot) EP = EPDM (Blue Dot) FS = SANIFLEX [Hytrel (Cream)] NE = NEOPRENE (Green Dot) PU = POLYURETHANE (Clear) TF = PTFE (White) VT = VITON (White Dot) WF = WIL-FLEX [Santoprene (Orange Dot)] VALVE SEAT K = PVDF P = POLYPROPYLENE VALVE SEAT & FLANGE O-RING BN = BUNA-N TV = PTFE ENCAP. VITON WF = WIL-FLEX (Santoprene) SPECIALTY CODES 0100 Wil-Gard 110V 0102 Wil-Gard sensor wires ONLY 0103 Wil-Gard 220V 0206 PFA coated hardware, Wil-Gard II sensor wires ONLY 0480 Pump Cycle Monitor (sensor & wires) 0483 Pump Cycle Monitor (module, sensor & wires) 0485 Pump Cycle Monitor (module, sensor & wires), DIN flange 0502 PFA Coated 0504 DIN Flange 0506 DIN Flange, PFA Coated 0513 SS outer pistons 0604 DIN flange Wil-Gard II 0608 PFA coated hardware, Wil-Gard II 220V 0690 Center-Ported ANSI/DIN Combo 0691 Center-ported, ANSI/DIN combo flange, PFA coated fasteners 0733 Center-ported, Reversed ANSI/DIN combo flange (inlet facing air inlet/discharge facing exhaust) 0734 Center-ported, Reversed ANSI/DIN combo flange (inlet facing air inlet/discharge facing exhaust), PFA coated fasteners NOTE: MOST ELASTOMERIC MATERIALS USE COLORED DOTS FOR IDENTIFICATION. NOTE: Not all models are available with all material options. Viton is a registered trademark of DuPont Dow Elastomers. WILDEN PUMP & ENGINEERING, LLC 2 WIL E-04

5 Section 3 HOW IT WORKS PUMP The Wilden diaphragm pump is an air-operated, positive displacement, self-priming pump. These drawings show flow pattern through the pump upon its initial stroke. It is assumed the pump has no fluid in it prior to its initial stroke. FIGURE 1 The air valve directs pressurized air to the back side of diaphragm A. The compressed air is applied directly to the liquid column separated by elastomeric diaphragms. The diaphragm acts as a separation membrane between the compressed air and liquid, balancing the load and removing mechanical stress from the diaphragm. The compressed air moves the diaphragm away from the center of the pump. The opposite diaphragm is pulled in by the shaft connected to the pressurized diaphragm. Diaphragm B is on its suction stroke; air behind the diaphragm has been forced out to atmosphere through the exhaust port of the pump. The movement of diaphragm B toward the center of the pump creates a vacuum within chamber B. Atmospheric pressure forces fluid into the inlet manifold forcing the inlet valve ball off its seat. Liquid is free to move past the inlet valve ball and fill the liquid chamber (see shaded area). FIGURE 2 When the pressurized diaphragm, diaphragm A, reaches the limit of its discharge stroke, the air valve redirects pressurized air to the back side of diaphragm B. The pressurized air forces diaphragm B away from the center while pulling diaphragm A to the center. Diaphragm B is now on its discharge stroke. Diaphragm B forces the inlet valve ball onto its seat due to the hydraulic forces developed in the liquid chamber and manifold of the pump. These same hydraulic forces lift the discharge valve ball off its seat, while the opposite discharge valve ball is forced onto its seat, forcing fluid to flow through the pump discharge. The movement of diaphragm A toward the center of the pump creates a vacuum within liquid chamber A. Atmospheric pressure forces fluid into the inlet manifold of the pump. The inlet valve ball is forced off its seat allowing the fluid being pumped to fill the liquid chamber. FIGURE 3 At completion of the stroke, the air valve again redirects air to the back side of diaphragm A, which starts diaphragm B on its exhaust stroke. As the pump reaches its original starting point, each diaphragm has gone through one exhaust and one discharge stroke. This constitutes one complete pumping cycle. The pump may take several cycles to completely prime depending on the conditions of the application. HOW IT WORKS AIR DISTRIBUTION SYSTEM The Pro-Flo patented air distribution system incorporates two moving parts: the air valve spool and the pilot spool. The heart of the system is the air valve spool and air valve. This valve design incorporates an unbalanced spool. The smaller end of the spool is pressurized continuously, while the large end is alternately pressurized then exhausted to move the spool. The spool directs pressurized air to one air chamber while exhausting the other. The air causes the main shaft/diaphragm assembly to shift to one side discharging liquid on that side and pulling liquid in on the other side. When the shaft reaches the end of its stroke, the inner piston actuates the pilot spool, which pressurizes and exhausts the large end of the air valve spool. The repositioning of the air valve spool routes the air to the other air chamber. WIL E-04 3 WILDEN PUMP & ENGINEERING, LLC

6 Section 4 DIMENSIONAL DRAWINGS P800 Plastic Side-Ported DIMENSIONS ITEM METRIC (mm) STANDARD (inch) A B C D E F G H J K L M N P R S DIN FLANGE T 125 DIA. 4.9 DIA. U 165 DIA. 6.5 DIA. V 18 DIA. 0.7 DIA. ANSI FLANGE T 122 DIA. 4.8 DIA. U 152 DIA. 6.0 DIA. V 20 DIA. 0.8 DIA. P800 Plastic Center-Ported DIMENSIONS ITEM METRIC (mm) STANDARD (inch) A B C D E F G H J K L M N P R S T U DIN / ANSI COMBO V 152 DIA. 6.0 DIA. W 122 DIA. 4.8 DIA. X 20 DIA. 0.8 DIA. WILDEN PUMP & ENGINEERING, LLC 4 WIL E-04

7 DIMENSIONAL DRAWING PX800 Plastic Side-Ported DIMENSIONS ITEM METRIC (mm) STANDARD (inch) A B C D E F G H J K L M N P R S DIN FLANGE T 125 DIA. 4.9 DIA. U 165 DIA. 6.5 DIA. V 18 DIA..7 DIA. ANSI FLANGE T 122 DIA. 4.8 DIA. U 154 DIA. 6.0 DIA. V 20 DIA..8 DIA. PX800 Plastic Center-Ported DIMENSIONS ITEM METRIC (mm) STANDARD (inch) A B C D E F G H J K L M N P R S T U DIN / ANSI COMBO V 152 DIA. 6.0 DIA. W 122 DIA. 4.8 DIA. X 20 DIA..8 DIA. WIL E-04 5 WILDEN PUMP & ENGINEERING, LLC

8 Section 5A P800 PLASTIC RUBBER-FITTED PERFORMANCE Height mm (31.7") Width mm (23.8") Depth mm (13.9") Est. Ship Weight Polypropylene 32 kg (70 lbs) PVDF 45 kg (99 lbs) Air Inlet...13 mm (1 2") Inlet mm (2") Outlet mm (2") Suction Lift m Dry (20.4') 8.65 m Wet (28.4') Displacement/Stroke 2.75 l (0.727 gal.) 1 Max. Flow Rate lpm (165 gpm) Max. Size Solids mm (1 4") 1 Displacement per stroke was calculated at 4.8 Bar (70 psig) air inlet pressure against a 2 bar (30 psig) head pressure. Example: To pump 246 lpm (65 gpm) against a discharge head pressure of 2.8 Bar (40 psig) requires 4.1 bar (60 psig) and 85 Nm 3 /h (50 scfm) air consumption. (See dot on chart.) Caution: Do not exceed 8.6 bar (125 psig) air supply pressure. Flow rates indicated on chart were determined by pumping water. For optimum life and performance, pumps should be specified so that daily operation parameters will fall in the center of the pump performance curve. P800 PLASTIC TPE-FITTED Height mm (31.7") Width mm (23.8") Depth mm (13.9") Est. Ship Weight Polypropylene 32 kg (70 lbs) PVDF 45 kg (99 lbs) Air Inlet...13 mm (1 2") Inlet mm (2") Outlet mm (2") Suction Lift m Dry (18.16') 8.66 m Wet (28.4') Displacement/Stroke l (0.735 gal.) 1 Max. Flow Rate lpm (162 gpm) Max. Size Solids mm (1 4") 1 Displacement per stroke was calculated at 4.8 bar (70 psig) air inlet pressure against a 2 bar (30 psig) head pressure. Example: To pump lpm (85 gpm) against a discharge head pressure of 1.2 bar (17 psig) requires 2.8 bar (40 psig) and 85 Nm 3 /h (50 scfm) air consumption. (See dot on chart.) Caution: Do not exceed 8.6 bar (125 psig) air supply pressure. Flow rates indicated on chart were determined by pumping water. For optimum life and performance, pumps should be specified so that daily operation parameters will fall in the center of the pump performance curve. WILDEN PUMP & ENGINEERING, LLC 6 WIL E-04

9 PERFORMANCE P800 PLASTIC REDUCED STROKE PTFE-FITTED Height mm (31.7") Width mm (23.8") Depth mm (13.9") Est. Ship Weight Polypropylene 32 kg (70 lbs) PVDF 45 kg (99 lbs) Air Inlet...13 mm (1 2") Inlet mm (2") Outlet mm (2") Suction Lift m Dry (13.62') 8.65 m Wet (28.4') Displacement/Stroke l (0.457 gal.) 1 Max. Flow Rate lpm (133 gpm) Max. Size Solids mm (1 4") 1 Displacement per stroke was calculated at 4.8 bar (70 psig) air inlet pressure against a 2 bar (30 psig) head pressure. Example: To pump lpm (58 gpm) against a discharge head pressure of 3.4 Bar (50 psig) requires 5.5 bar (80 psig) and 128 Nm 3 /h (75 scfm) air consumption. (See dot on chart.) Caution: Do not exceed 8.6 bar (125 psig) air supply pressure. Flow rates indicated on chart were determined by pumping water. For optimum life and performance, pumps should be specified so that daily operation parameters will fall in the center of the pump performance curve. P800 PLASTIC FULL STROKE PTFE-FITTED Height mm (31.7 ) Width mm (23.8 ) Depth mm (13.9 ) Ship Weight. Polypropylene 32 kg (70 lbs.) PVDF 45 kg (99 lbs.) Air Inlet...13 mm (1/2 ) Inlet...51 mm (2 ) Outlet...51 mm (2 ) Suction Lift m Dry (19.5 ) 9.0 m Wet (29.5 ) Disp. Per Stroke l (0.67 gal.) 1 Max. Flow Rate lpm (162 gpm) Max. Size Solids mm (1/4 ) 1 Displacement per stroke was calculated at 4.8 bar (70 psig) air inlet pressure against a 2.1 bar (30 psig)head pressure. Example: To pump 98 GPM against a discharge head of 40 psigrequires 80 psig and 92 scfm air consumption. Caution: Do not exceed 8.6 bar (125 psig) air supply pressure. 20 [34] 40 [68] 60 [102] 80 [136] 100 [170] 120 [204] [76] [151] [227] [303] [379] [454] [530] [606] Flow rates indicated on chart were determined by pumping water. For optimum life and performance, pumps should be specified so that daily operation parameters will fall in the center of the pump performance curve. WIL E-04 7 WILDEN PUMP & ENGINEERING, LLC

10 P800 PLASTIC ULTRA-FLEX -FITTED PERFORMANCE Height mm (31.7") Width mm (23.8") Depth mm (13.9") Est. Ship Weight Polypropylene 32 kg (70 lbs) PVDF 45 kg (99 lbs) Air Inlet...13 mm (1 2") Inlet mm (2") Outlet mm (2") Suction Lift m Dry (15.89') 8.65 m Wet (28.4') Displacement/Stroke l (0.457 gal.) 1 Max. Flow Rate lpm (155 gpm) Max. Size Solids mm (1 4") 1 Displacement per stroke was calculated at 4.8 bar (70 psig) air inlet pressure against a 2 bar (30 psig) head pressure. Example: To pump 265 lpm (70 gpm) against a discharge head pressure of 1.7 bar (24 psig) requires 2.8 bar (40 psig) and 85 Nm 3 /h (50 scfm) air consumption. (See dot on chart.) Caution: Do not exceed 8.6 bar (125 psig) air supply pressure. Flow rates indicated on chart were determined by pumping water. For optimum life and performance, pumps should be specified so that daily operation parameters will fall in the center of the pump performance curve. WILDEN PUMP & ENGINEERING, LLC 8 WIL E-04

11 Section 5A SUCTION LIFT CURVE P800 PLASTIC SUCTION LIFT CAPABILITY WIL E-04 9 WILDEN PUMP & ENGINEERING, LLC

12 NOTES

13 PX800 P L A S T I C PX800 PERFORMANCE WIL E WILDEN PUMP & ENGINEERING, LLC

14 Section 5B Pro-Flo X TM Operating Principal The Pro-Flo X air distribution system with the revolutionary Efficiency Management System (EMS) offers flexibility never before seen in the world of AODD pumps. The patent-pending EMS is simple and easy to use. With the turn of an integrated control dial, the operator can select the optimal balance of flow and efficiency that best meets the application needs. Pro-Flo X provides higher performance, lower operational costs and flexibility that exceeds previous industry standards. AIR CONSUMPTION $$$ Turning the dial changes the relationship between air inlet and exhaust porting. Each dial setting represents an entirely different flow curve Pro-Flo X pumps are shipped from the factory on setting 4, which is the highest flow rate setting possible Moving the dial from setting 4 causes a decrease in flow and an even greater decrease in air consumption. When the air consumption decreases more than the flow rate, efficiency is improved and operating costs are reduced. WILDEN PUMP & ENGINEERING, LLC 12 PX800 Performance

15 HOW TO USE THIS EMS CURVE Example 1 SETTING 4 PERFORMANCE CURVE EMS CURVE Figure 1 Figure 2 flow multiplier Example data point = 8.2 GPM Example data point = air multiplier This is an example showing how to determine flow rate and air consumption for your Pro-Flo X pump using the Efficiency Management System (EMS) curve and the performance curve. For this example we will be using 4.1 bar (60 psig) inlet air pressure and 2.8 bar (40 psig) discharge pressure and EMS setting 2. Step 1: Identifying performance at setting 4. Locate the curve that represents the flow rate of the pump with 4.1 bar (60 psig) air inlet pressure. Mark the point where this curve crosses the horizontal line representing 2.8 bar (40 psig) discharge pressure. (Figure 1). After locating your performance point on the flow curve, draw a vertical line downward until reaching the bottom scale on the chart. Identify the flow rate (in this case, 8.2 gpm). Observe location of performance point relative to air consumption curves and approximate air consumption value (in this case, 9.8 scfm). Step 2: Determining flow and air X Factors. Locate your discharge pressure (40 psig) on the vertical axis of the EMS curve (Figure 2). Follow along the 2.8 bar (40 psig) horizontal line until intersecting both flow and air curves for your desired EMS setting (in this case, setting 2). Mark the points where the EMS curves intersect the horizontal discharge pressure line. After locating your EMS points on the EMS curve, draw vertical lines downward until reaching the bottom scale on the chart. This identifies the flow X Factor (in this case, 0.58) and air X Factor (in this case, 0.48). Step 3: Calculating performance for specific EMS setting. Multiply the flow rate (8.2 gpm) obtained in Step 1 by the flow X Factor multiplier (0.58) in Step 2 to determine the flow rate at EMS setting 2. Multiply the air consumption (9.8 scfm) obtained in Step 1 by the air X Factor multiplier (0.48) in Step 2 to determine the air consumption at EMS setting 2 (Figure 3). Figure gpm (flow rate for Setting 4) gpm (Flow rate for setting 2) 9.8 scfm scfm (Flow X Factor setting 2) (air consumption for setting 4) (Air X Factor setting 2) (air consumption for setting 2) The flow rate and air consumption at Setting 2 are found to be 18.2 lpm (4.8 gpm) and 7.9 Nm 3 /h (4.7 scfm) respectively. PX800 Performance 13 WILDEN PUMP & ENGINEERING, LLC

16 HOW TO USE THIS EMS CURVE Example 2.1 SETTING 4 PERFORMANCE CURVE EMS CURVE EMS Flow Settings 1 & 2 Figure 4 Example data point = 10.2 gpm 0.49 flow multiplier Figure 5 This is an example showing how to determine the inlet air pressure and the EMS setting for your Pro-Flo X pump to optimize the pump for a specific application. For this example we will be using an application requirement of 18.9 lpm (5 gpm) flow rate against 2.8 bar (40 psig) discharge pressure. This example will illustrate how to calculate the air consumption that could be expected at this operational point. DETERMINE EMS SETTING Step 1: Establish inlet air pressure. Higher air pressures will typically allow the pump to run more efficiently, however, available plant air pressure can vary greatly. If an operating pressure of 6.9 bar (100 psig) is chosen when plant air frequently dips to 6.2 bar (90 psig) pump performance will vary. Choose an operating pressure that is within your compressed air system's capabilities. For this example we will choose 4.1 bar (60 psig). Step 2: Determine performance point at setting 4. For this example an inlet air pressure of 4.1 bar (60 psig) inlet air pressure has been chosen. Locate the curve that represents the performance of the pump with 4.1 bar (60 psig) inlet air pressure. Mark the point where this curve crosses the horizontal line representing 2.8 bar (40 psig) discharge pressure. After locating this point on the flow curve, draw a vertical line downward until reaching the bottom scale on the chart and identify the flow rate. In our example it is 38.6 lpm (10.2 gpm). This is the setting 4 flow rate. Observe the location of the performance point relative to air consumption curves and approximate air consumption value. In our example setting 4 air consumption is 24 Nm 3 /h (14 scfm). See figure 4. Step 3: Determine flow X Factor. Divide the required flow rate 18.9 lpm (5 gpm) by the setting 4 flow rate 38.6 lpm (10.2 gpm) to determine the flow X Factor for the application. 5 gpm / 10.2 gpm = 0.49 (flow X Factor) Step 4: Determine EMS setting from the flow X Factor. Plot the point representing the flow X Factor (0.49) and the application discharge pressure 2.8 bar (40 psig) on the EMS curve. This is done by following the horizontal 2.8 bar (40 psig) psig discharge pressure line until it crosses the vertical 0.49 X Factor line. Typically, this point lies between two flow EMS setting curves (in this case, the point lies between the flow curves for EMS setting 1 and 2). Observe the location of the point relative to the two curves it lies between and approximate the EMS setting (figure 5). For more precise results you can mathematically interpolate between the two curves to determine the optimal EMS setting. For this example the EMS setting is 1.8. WILDEN PUMP & ENGINEERING, LLC 14 PX800 Performance

17 HOW TO USE THIS EMS CURVE Example 2.2 SETTING 4 PERFORMANCE CURVE EMS CURVE EMS Air Settings 1 & 2 Figure 6 Example data point = 10.2 gpm Example data point = 0.40 air multiplier Figure 7 Determine air consumption at a specific EMS setting. Step 1: Determine air X Factor. In order to determine the air X Factor, identify the two air EMS setting curves closest to the EMS setting established in example 2.1 (in this case, the point lies between the air curves for EMS setting 1 and 2). The point representing your EMS setting (1.8) must be approximated and plotted on the EMS curve along the horizontal line representing your discharge pressure (in this case, 40 psig). This air point is different than the flow point plotted in example 2.1. After estimating (or interpolating) this point on the curve, draw a vertical line downward until reaching the bottom scale on the chart and identify the air X Factor (figure 7). Step 2: Determine air consumption. Multiply your setting 4 air consumption (14 scfm) value by the air X Factor obtained above (0.40) to determine your actual air consumption. 14 scfm x 0.40 = 5.6 SCFM In summary, for an application requiring 18.9 lpm (5 gpm) against 2.8 bar (40 psig) discharge pressure, the pump inlet air pressure should be set to 4.1 bar (60 psig) and the EMS dial should be set to 1.8. The pump would then consume 9.5 Nm 3 /h (5.6 scfm) of compressed air. For this example the air X Factor is 0.40 PX800 Performance 15 WILDEN PUMP & ENGINEERING, LLC

18 PERFORMANCE PX800 PLASTIC RUBBER-FITTED SETTING 4 PERFORMANCE CURVE EMS CURVE TECHNICAL DATA Height mm (31.7 ) Width mm (23.8 ) Depth mm (14.0 ) Ship Weight Polypropylene 33 kg (70 lbs.) PVDF 45 kg (99 lbs.) Air Inlet mm (3/4 ) Inlet mm (2 ) Outlet mm (2 ) Suction Lift m Dry (19.9 ) m Wet (29.5 ) Disp. Per Stroke l (0.70 gal.) 1 Max. Flow Rate lpm (183 gpm) Max. Size Solids mm (1/4 ) 1 Displacement per stroke was calculated at 4.8 bar (70 psig) air inlet pressure against a 2.1 bar (30 psig)head pressure. The Efficiency Management System (EMS) can be used to optimize the performance of your Wilden pump for specific applications. The pump is delivered with the EMS adjusted to setting 4, which allows maximum flow. The EMS curve allows the pump user to determine flow and air consumption at each EMS setting. For any EMS setting and discharge pressure, the X factor is used as a multiplier with the original values from the setting 4 performance curve to calculate the actual flow and air consumption values for that specific EMS setting. Note: you can interpolate between the setting curves for operation at intermediate EMS settings. Example: A PX800 polypropylene, rubber-fitted pump operating at EMS setting 4, achieved a flow rate of 303 lpm (80 gpm) using 88 Nm3/h (52 scfm) of air when run at 4.1 bar (60 psig) air inlet pressure and 2.1 bar (30 psig) discharge pressure (See dot on performance curve). The end user did not require that much flow and wanted to reduce air consumption at his facility. He determined that EMS setting 1 would meet his needs. At 1.4 bar (20 psig) discharge pressure and EMS setting 1, the flow X factor is 0.28 and the air X factor is 0.19 (see dots on EMS curve). Multiplying the original setting 4 values by the X factors provides the setting 1 flow rate of 85 lpm (22 gpm) and an air consumption of 17 Nm3/h (10 scfm). The flow rate was reduced by 72% while the air consumption was reduced by 81%, thus providing increased efficiency. For a detailed example for how to set your EMS, see beginning of performance curve section. Caution: Do not exceed 8.6 bar (125 psig) air supply pressure. WILDEN PUMP & ENGINEERING, LLC 16 PX800 Performance

19 PERFORMANCE PX800 PLASTIC TPE-FITTED SETTING 4 PERFORMANCE CURVE EMS CURVE TECHNICAL DATA Height mm (31.7 ) Width mm (23.8 ) Depth mm (14.0 ) Ship Weight Polypropylene 33 kg (70 lbs.) PVDF 45 kg (99 lbs.) Air Inlet mm (3/4 ) Inlet mm (2 ) Outlet mm (2 ) Suction Lift m Dry (17.6 ) m Wet (29.5 ) Disp. Per Stroke l (0.70 gal.) 1 Max. Flow Rate lpm (182 gpm) Max. Size Solids mm (1/4 ) 1 Displacement per stroke was calculated at 4.8 bar (70 psig) air inlet pressure against a 2.1 bar (30 psig)head pressure. The Efficiency Management System (EMS) can be used to optimize the performance of your Wilden pump for specific applications. The pump is delivered with the EMS adjusted to setting 4, which allows maximum flow. The EMS curve allows the pump user to determine flow and air consumption at each EMS setting. For any EMS setting and discharge pressure, the X factor is used as a multiplier with the original values from the setting 4 performance curve to calculate the actual flow and air consumption values for that specific EMS setting. Note: you can interpolate between the setting curves for operation at intermediate EMS settings. EXAMPLE A PX800 polypropylene, TPE-fitted pump operating at EMS setting 4, achieved a flow rate of 522 lpm (138 gpm) using 170 Nm 3 /h (100 scfm) of air when run at 6.9 bar (100 psig) air inlet pressure and 1.4 bar (20 psig) discharge pressure (See dot on performance curve). The end user did not require that much flow and wanted to reduce air consumption at his facility. He determined that EMS setting 2 would meet his needs. At 1.4 bar (20 psig) discharge pressure and EMS setting 2, the flow X factor is 0.68 and the air X factor is 0.48 (see dots on EMS curve). Multiplying the original setting 4 values by the X factors provides the setting 2 flow rate of 355 lpm (94 gpm) and an air consumption of 82 Nm 3 /h (48 scfm). The flow rate was reduced by 32% while the air consumption was reduced by 52%, thus providing increased efficiency. For a detailed example for how to set your EMS, see beginning of performance curve section. Caution: Do not exceed 8.6 bar (125 psig) air supply pressure. PX800 Performance 17 WILDEN PUMP & ENGINEERING, LLC

20 PERFORMANCE PX800 PLASTIC REDUCED STROKE PTFE-FITTED SETTING 4 PERFORMANCE CURVE EMS CURVE TECHNICAL DATA Height mm (31.7 ) Width mm (23.8 ) Depth mm (14.0 ) Ship Weight Polypropylene 33 kg (70 lbs.) PVDF 45 kg (99 lbs.) Air Inlet mm (3/4 ) Inlet mm (2 ) Outlet mm (2 ) Suction Lift m Dry (14.8 ) m Wet (23.8 ) Disp. Per Stroke l (0.46 gal.) 1 Max. Flow Rate lpm (153 gpm) Max. Size Solids mm (1/4 ) 1 Displacement per stroke was calculated at 4.8 bar (70 psig) air inlet pressure against a 2.1 bar (30 psig)head pressure. The Efficiency Management System (EMS) can be used to optimize the performance of your Wilden pump for specific applications. The pump is delivered with the EMS adjusted to setting 4, which allows maximum flow. The EMS curve allows the pump user to determine flow and air consumption at each EMS setting. For any EMS setting and discharge pressure, the X factor is used as a multiplier with the original values from the setting 4 performance curve to calculate the actual flow and air consumption values for that specific EMS setting. Note: you can interpolate between the setting curves for operation at intermediate EMS settings. EXAMPLE A PX800 polypropylene, reduced stroke PTFE-fitted pump operating at EMS setting 4, achieved a flow rate of 439 lpm (116 gpm) using 146 Nm 3 /h (86 scfm) of air when run at 5.5 bar (80 psig) air inlet pressure and 0.7 bar (10 psig) discharge pressure (See dot on performance curve). The end user did not require that much flow and wanted to reduce air consumption at his facility. He determined that EMS setting 2 would meet his needs. At 0.7 bar (10 psig) discharge pressure and EMS setting 2, the flow X factor is 0.67 and the air X factor is 0.46 (see dots on EMS curve). Multiplying the original setting 4 values by the X factors provides the setting 2 flow rate of 294 lpm (78 gpm) and an air consumption of 67 Nm 3 /h (40 scfm). The flow rate was reduced by 33% while the air consumption was reduced by 54%, thus providing increased efficiency. For a detailed example for how to set your EMS, see beginning of performance curve section. Caution: Do not exceed 8.6 bar (125 psig) air supply pressure. WILDEN PUMP & ENGINEERING, LLC 18 PX800 Performance

21 PERFORMANCE PX800 PLASTIC FULL STROKE PTFE-FITTED SETTING 4 PERFORMANCE CURVE EMS CURVE TECHNICAL DATA Height mm (31.7 ) Width mm (23.8 ) Depth mm (14.0 ) Ship Weight Polypropylene 33 kg (70 lbs.) PVDF 45 kg (99 lbs.) Air Inlet mm (3/4 ) Inlet mm (2 ) Outlet mm (2 ) Suction Lift m Dry (19.5 ) m Wet (29.5 ) Disp. Per Stroke l (0.67 gal.)1 Max. Flow Rate lpm (175.4 gpm) Max. Size Solids mm (1/4 ) 1 Displacement per stroke was calculated at 4.8 bar (70 psig) air inlet pressure against a 2.1 bar (30 psig)head pressure. The Efficiency Management System (EMS) can be used to optimize the performance of your Wilden pump for specific applications. The pump is delivered with the EMS adjusted to setting 4, which allows maximum flow. The EMS curve allows the pump user to determine flow and air consumption at each EMS setting. For any EMS setting and discharge pressure, the X factor is used as a multiplier with the original values from the setting 4 performance curve to calculate the actual flow and air consumption values for that specific EMS setting. Note: you can interpolate between the setting curves for operation at intermediate EMS settings. EXAMPLE A PX800 plastic, full stroke PTFE fitted pump operating at EMS setting 4, achieved a flow rate of 416 lpm (110 gpm) using 129 Nm 3 /h (76 scfm) of air when run at 5.5 bar (80 psig) air inlet pressure and 2.1 bar (30 psig) discharge pressure (See dot on performance curve). The end user did not require that much flow and wanted to reduce air consumption at his facility. He determined that EMS setting 3 would meet his needs. At 2.1 bar (30 psig) discharge pressure and EMS setting 3, the flow X factor is 0.74 and the air X factor is 0.66 (see dots on EMS curve). Multiplying the original setting 4 values by the X factors provides the setting 3 flow rate of 308 lpm (81 gpm) and an air consumption of 85 Nm 3 /h (50 scfm). The flow rate was reduced by 26% while the air consumption was reduced by 34%, thus providing increased efficiency. For a detailed example for how to set your EMS, see beginning of performance curve section. Caution: Do not exceed 8.6 bar (125 psig) air supply pressure. PX800 Performance 19 WILDEN PUMP & ENGINEERING, LLC

22 PERFORMANCE PX800 PLASTIC ULTRA-FLEX TM FITTED SETTING 4 PERFORMANCE CURVE EMS CURVE TECHNICAL DATA Height mm (31.7 ) Width mm (23.8 ) Depth mm (14.0 ) Ship Weight Polypropylene 33 kg (70 lbs.) PVDF 45 kg (99 lbs.) Air Inlet mm (3/4 ) Inlet mm (2 ) Outlet mm (2 ) Suction Lift m Dry (15.9 ) m Wet (26.1 ) Disp. Per Stroke l (0.45 gal.) 1 Max. Flow Rate lpm (167 gpm) Max. Size Solids mm (1/4 ) 1 Displacement per stroke was calculated at 4.8 bar (70 psig) air inlet pressure against a 2.1 bar (30 psig) head pressure. The Efficiency Management System (EMS) can be used to optimize the performance of your Wilden pump for specific applications. The pump is delivered with the EMS adjusted to setting 4, which allows maximum flow. The EMS curve allows the pump user to determine flow and air consumption at each EMS setting. For any EMS setting and discharge pressure, the X factor is used as a multiplier with the original values from the setting 4 performance curve to calculate the actual flow and air consumption values for that specific EMS setting. Note: you can interpolate between the setting curves for operation at intermediate EMS settings. EXAMPLE A PX800 polypropylene, Ultra-Flex-fitted pump operating at EMS setting 4, achieved a flow rate of 220 lpm (58 gpm) using 131 Nm3/h (77 scfm) of air when run at 6.9 bar (100 psig) air inlet pressure and 4.1 bar (60 psig) discharge pressure (See dot on performance curve). The end user did not require that much flow and wanted to reduce air consumption at his facility. He determined that EMS setting 3 would meet his needs. At 4.1 bar (60 psig) discharge pressure and EMS setting 3, the flow X factor is 0.89 and the air X factor is 0.81 (see dots on EMS curve). Multiplying the original setting 4 values by the X factors provides the setting 3 flow rate of 195 lpm (52 gpm) and an air consumption of 106 Nm3/h (62 scfm). The flow rate was reduced by 11% while the air consumption was reduced by 19%, thus providing increased efficiency. For a detailed example for how to set your EMS, see beginning of performance curve section. Caution: Do not exceed 8.6 bar (125 psig) air supply pressure. WILDEN PUMP & ENGINEERING, LLC 20 PX800 Performance

23 Section 5C SUCTION LIFT CURVE PX800 PLASTIC SUCTION LIFT CAPABILITY Traditional Rubber Diaphragms TPE Diaphragms UltraFlex Diaphragms Reduced Stroke PTFE Diaphragms Full Stroke PTFE Diaphragms PX800 Performance 21 WILDEN PUMP & ENGINEERING, LLC

24 22069 Van Buren St. Grand Terrace, CA Tel Fax Take control of your process today with

25 Section 6 SUGGESTED INSTALLATION Wilden pumps are designed to meet the performance requirements of even the most demanding pumping applications. They have been designed and manufactured to the highest standards and are available in a variety of liquid path materials to meet your chemical resistance needs. Refer to the performance section of this manual for an in-depth analysis of the performance characteristics of your pump. Wilden offers the widest variety of elastomer options in the industry to satisfy temperature, chemical compatibility, abrasion resistance and flex concerns. The suction pipe size should be at least the equivalent or larger than the diameter size of the suction inlet on your Wilden pump. The suction hose must be non-collapsible, reinforced type as these pumps are capable of pulling a high vacuum. Discharge piping should also be the equivalent or larger than the diameter of the pump discharge which will help reduce friction losses. It is critical that all fittings and connections are airtight or a reduction or loss of pump suction capability will result. INSTALLATION: Months of careful planning, study, and selection efforts can result in unsatisfactory pump performance if installation details are left to chance. Premature failure and long term dissatisfaction can be avoided if reasonable care is exercised throughout the installation process. LOCATION: Noise, safety, and other logistical factors usually dictate where equipment will be situated on the production floor. Multiple installations with conflicting requirements can result in congestion of utility areas, leaving few choices for additional pumps. Within the framework of these and other existing conditions, every pump should be located in such a way that six key factors are balanced against each other to maximum advantage. ACCESS: First of all, the location should be accessible. If it s easy to reach the pump, maintenance personnel will have an easier time carrying out routine inspections and adjustments. Should major repairs become necessary, ease of access can play a key role in speeding the repair process and reducing total downtime. AIR SUPPLY: Every pump location should have an air line large enough to supply the volume of air necessary to achieve the desired pumping rate. Use air pressure up to a maximum of 8.6 bar (125 psig) depending on pumping requirements. For best results, the pumps should use a 5µ (micron) air filter, needle valve and regulator. The use of an air filter before the pump will ensure that the majority of any pipeline contaminants will be eliminated. SOLENOID OPERATION: When operation is controlled by a solenoid valve in the air line, three-way valves should be used. This valve allows trapped air between the valve and the pump to bleed off which improves pump performance. Pumping volume can be estimated by counting the number of strokes per minute and then multiplying the figure by the displacement per stroke. MUFFLER: Sound levels are reduced below OSHA specifications using the standard Wilden muffler. Other mufflers can be used to further reduce sound levels, but they usually reduce pump performance. ELEVATION: Selecting a site that is well within the pump s dynamic lift capability will assure that loss-of-prime issues will be eliminated. In addition, pump efficiency can be adversely affected if proper attention is not given to site location. PIPING: Final determination of the pump site should not be made until the piping challenges of each possible location have been evaluated. The impact of current and future installations should be considered ahead of time to make sure that inadvertent restrictions are not created for any remaining sites. The best choice possible will be a site involving the shortest and straightest hook-up of suction and discharge piping. Unnecessary elbows, bends, and fittings should be avoided. Pipe sizes should be selected to keep friction losses within practical limits. All piping should be supported independently of the pump. In addition, the piping should be aligned to avoid placing stress on the pump fittings. Flexible hose can be installed to aid in absorbing the forces created by the natural reciprocating action of the pump. If the pump is to be bolted down to a solid location, a mounting pad placed between the pump and the foundation will assist in minimizing pump vibration. Flexible connections between the pump and rigid piping will also assist in minimizing pump vibration. If quick-closing valves are installed at any point in the discharge system, or if pulsation within a system becomes a problem, a surge suppressor (SD Equalizer ) should be installed to protect the pump, piping and gauges from surges and water hammer. If the pump is to be used in a self-priming application, make sure that all connections are airtight and that the suction lift is within the model s ability. Note: Materials of construction and elastomer material have an effect on suction lift parameters. Please refer to the performance section for specifics. When pumps are installed in applications involving flooded suction or suction head pressures, a gate valve should be installed in the suction line to permit closing of the line for pump service. Pumps in service with a positive suction head are most efficient when inlet pressure is limited to bar (7 10 psig). Premature diaphragm failure may occur if positive suction is 0.7 bar (10 psig) and higher. SUBMERSIBLE APPLICATIONS: Pro-Flo X pumps can be used for submersible applications, when using the Pro-Flo X single point exhaust option. NOTE: Pro-Flo and Accu-Flo pumps are not submersible. ALL WILDEN PUMPS ARE CAPABLE OF PASSING SOLIDS. A STRAINER SHOULD BE USED ON THE PUMP INTAKE TO ENSURE THAT THE PUMP'S RATED SOLIDS CAPACITY IS NOT EXCEEDED. CAUTION: DO NOT EXCEED 8.6 BAR (125 PSIG) AIR SUPPLY PRESSURE. WIL E WILDEN PUMP & ENGINEERING, LLC

26 SUGGESTED INSTALLATION This illustration is a generic representation of an air-operated double-diaphragm pump. NOTE: In the event of a power failure, the shut off valve should be closed, if the restarting of the pump is not desirable once power is regained. AIR OPERATED PUMPS: To stop the pump from operating in an emergency situation, simply close the shut off valve (user supplied) installed in the air supply line. A properly functioning valve will stop the air supply to the pump, therefore stopping output. This shut off valve should be located far enough away from the pumping equipment such that it can be reached safely in an emergency situation. WILDEN PUMP & ENGINEERING, LLC 24 WIL E-04

27 SUGGESTED OPERATION & MAINTENANCE OPERATION: The P800 and PX800 are pre-lubricated, and do not require in-line lubrication. Additional lubrication will not damage the pump, however if the pump is heavily lubricated by an external source, the pump s internal lubrication may be washed away. If the pump is then moved to a non-lubricated location, it may need to be disassembled and re-lubricated as described in the ASSEMBLY/DISASSEMBLY INSTRUCTIONS. Pump discharge rate can be controlled by limiting the volume and/or pressure of the air supply to the pump. An air regulator is used to regulate air pressure. A needle valve is used to regulate volume. Pump discharge rate can also be controlled by throttling the pump discharge by partially closing a valve in the discharge line of the pump. This action increases friction loss which reduces flow rate. (See Section 5.) This is useful when the need exists to control the pump from a remote location. When the pump discharge pressure equals or exceeds the air supply pressure, the pump will stop; no bypass or pressure relief valve is needed, and pump damage will not occur. The pump has reached a deadhead situation and can be restarted by reducing the fluid discharge pressure or increasing the air inlet pressure. The Wilden P800 and PX800 pumps run solely on compressed air and do not generate heat, therefore your process fluid temperature will not be affected. MAINTENANCE AND INSPECTIONS: Since each application is unique, maintenance schedules may be different for every pump. Frequency of use, line pressure, viscosity and abrasiveness of process fluid all affect the parts life of a Wilden pump. Periodic inspections have been found to offer the best means for preventing unscheduled pump downtime. Personnel familiar with the pump s construction and service should be informed of any abnormalities that are detected during operation. RECORDS: When service is required, a record should be made of all necessary repairs and replacements. Over a period of time, such records can become a valuable tool for predicting and preventing future maintenance problems and unscheduled downtime. In addition, accurate records make it possible to identify pumps that are poorly suited to their applications. TROUBLESHOOTING Pump will not run or runs slowly. 1. Ensure that the air inlet pressure is at least 0.4 bar (5 psig) above startup pressure and that the differential pressure (the difference between air inlet and liquid discharge pressures) is not less than 0.7 bar (10 psig). 2. Check air inlet filter for debris (see recommended installation). 3. Check for extreme air leakage (blow by) which would indicate worn seals/bores in the air valve, pilot spool, main shaft. 4. Disassemble pump and check for obstructions in the air passageways or objects which would obstruct the movement of internal parts. 5. Check for sticking ball check valves. If material being pumped is not compatible with pump elastomers, swelling may occur. Replace ball check valves and seals with proper elastomers. Also, as the check valve balls wear out, they become smaller and can become stuck in the seats. In this case, replace balls and seats. 6. Check for broken inner piston which will cause the air valve spool to be unable to shift. 7. Remove plug from pilot spool exhaust. Pump runs but little or no product flows. 1. Check for pump cavitation; slow pump speed down to allow thick material to flow into liquid chambers. 2. Verify that vacuum required to lift liquid is not greater than the vapor pressure of the material being pumped (cavitation). 3. Check for sticking ball check valves. If material being pumped is not compatible with pump elastomers, swelling may occur. Replace ball check valves and seats with proper elastomers. Also, as the check valve balls wear out, they become smaller and can become stuck in the seats. In this case, replace balls and seats. Pump air valve freezes. 1. Check for excessive moisture in compressed air. Either install a dryer or hot air generator for compressed air. Alternatively, a coalescing filter may be used to remove the water from the compressed air in some applications. Air bubbles in pump discharge. 1. Check for ruptured diaphragm. 2. Check tightness of outer pistons (refer to Section 7). 3. Check tightness of fasteners and integrity of o-rings and seals, especially at intake manifold. 4. Ensure pipe connections are airtight. Product comes out air exhaust. 1. Check for diaphragm rupture. 2. Check tightness of outer pistons to shaft. WIL E WILDEN PUMP & ENGINEERING, LLC

28 Section 7 PUMP DISASSEMBLY Tools Required: 3/4" Wrench Adjustable Wrench Vise equipped w/soft jaws (such as plywood, plastic or other suitable material) CAUTION: Before any maintenance or repair is attempted, the compressed air line to the pump should be disconnected and all air pressure allowed to bleed from the pump. Disconnect all intake, discharge, and air lines. Drain the pump by turning it upside down and allowing any fluid to flow into a suitable container. Be aware of any hazardous effects of contact with your process fluid. NOTE: The model photographed for these instructions incorporates PTFE diaphragms, balls, and seats. Models with rubber diaphragms, balls and seats are the same except where noted. Step 1 Please note alignment marks on liquid chambers. Use to properly align center section with liquid chamber. Step 2 Using a 3/4" wrench, loosen the discharge manifold from the liquid chambers. Step 3 Remove the discharge manifold to expose the valve balls, valve seats and valve seat o-rings. WILDEN PUMP & ENGINEERING, LLC 26 WIL E-04

29 PUMP DISASSEMBLY Step 4 Step 5 Step 6 Inspect valve balls, valve seats, and valve seat o-rings for nicks, gouges, chemical attack or abrasive wear. Using a 3/4" wrench, lossen the inlet manfold from the liquid chambers. Remove the inlet manifold, valve balls, valve seats and valve seat o-rings and inspect for nicks, gouges, chemical attack or abrasive wear. Step 7 Using a 3/4" wrench, remove the liquid chamber fasteners that secure the liquid chamber to the center section. Step 8 Remove the liquid chamber to expose the diaphragm and outer piston. Step 9 Using two adjustable wrenches, or rotating both diaphragms by hand (counterclockwise), remove the diaphragm assembly from the center section assembly. WIL E WILDEN PUMP & ENGINEERING, LLC

30 PUMP DISASSEMBLY Step 10 Due to varying torque values, one of the following two situations may occur: 1) The outer piston, diaphragm and inner piston remain attached to the shaft and the entire assembly can be removed from the center section. 2) The outer piston, diaphragm and inner piston separate from the shaft, which remains connected to the opposite side diaphragm assembly. Step 11 Remove diaphragm assembly from shaft, secure shaft with soft jaws (a vise fitted with plywood, plastic or other suitable material) to ensure shaft is not nicked, scratched or gouged. Using an adjustable wrench or rotating counterclockwise by hand, remove diaphragm assembly from shaft. WILDEN PUMP & ENGINEERING, LLC 28 WIL E-04

31 Section 7B PRO-FLO AIR DISTRIBUTION SYSTEM (ADS) DISASSEMBLY Tools Required: 3/16" Wrench O-ring Pick CAUTION: Before any maintenance or repair is attempted, the compressed air line to the pump should be disconnected and all air pressure allowed to bleed from the pump. Disconnect all intake, discharge, and air lines. Drain the pump by turning it upside down and allowing any fluid to flow into a suitable container. Be aware of hazardous effects of contact with your process fluid. Step 1 Using a 3/16 hex head wrench, loosen air valve bolts. Step 2 Remove muffler plate and air valve bolts from air valve assembly, exposing muffler gasket for inspection. Replace if necessary. Step 3 Lift away air valve assembly and remove air valve gasket for inspection. Replace if necessary. WIL E WILDEN PUMP & ENGINEERING, LLC

32 PRO-FLO AIR DISTRIBUTION SYSTEM (ADS) DISASSEMBLY Step 4 Remove air valve end cap to expose air valve spool by simply lifting up on end cap once air valve bolts are removed. Note: Pro-Flo V air valve incorporates an end cap at both end of the air valve. Step 5 Remove the air valve spool from the air valve body by threading one air valve bolt into the end of the air valve spool and gently sliding the spool out of the air valve body. Inspect seals for signs of wear and replace entire assembly if necessary. Use caution when handling air valve spool to prevent damaging seals. Note: Seals should not be removed from assembly. Seals are not sold separately. Step 6 Remove pilot sleeve from center section. To do so, the air chambers must be remove from thecenter block which will expose the pilot spool sleeve. WILDEN PUMP & ENGINEERING, LLC 30 WIL E-04

33 PRO-FLO AIR DISTRIBUTION SYSTEM (ADS) DISASSEMBLY NOTCHED END Step 7 Using an o-ring pick, gently remove the o-ring from the opposite side of the notched end on one side of the pilot spool. Gently remove the pilot spool from pilot spool sleeve and inspect for nicks, gouges and wear. Replace pilot sleeve or outer sleeve o-rings if necessary. During re-assembly, never insert the pilot spool into the sleeve with the notched end first, this end incorporates the urethane o-ring and will be damaged as it slides over the ports cut in the sleeve. Note: Seals should not be removed from pilot spool. Seals are not sold separately. Step 8 Inspect center section seals for signs of wear. If necessary, remove seals with o-ring pick and replace. WIL E WILDEN PUMP & ENGINEERING, LLC

34 Section 7C PRO-FLO X AIR DISTRIBUTION SYSTEM (ADS) DISASSEMBLY Step 1. Figure 1 Loosen the air valve bolts using a 3/16" hex wrench. Step 2. Figure 2 Remove air valve bolts, muffler plate, and air valve assembly exposing muffler gasket and air valve gasket. Replace if necessary. Step 3. Figure 3 Remove air valve end cap to expose the large end of air valve spool by simply lifting up on the air valve end cap once the bolts have been removed. Step 4. Figure 4 Step 5. Figure 5 Step 6-6A. Figure 6 Remove air valve spool from air valve body by threading one air valve bolt into the end of the spool and gently sliding the spool out of the air valve body. Inspect seals for signs of wear and replace entire assembly if necessary. Use caution when handling air valve spool to prevent damaging seals. NOTE: Seals should not be remove from assembly. Seals are not sold separately. Remove pilot spool retaining snap ring on both sides of the center section using snap ring pliers. Remove the air chamber bolts using a 1/4" hex wrench. WILDEN PUMP & ENGINEERING, LLC 32 WIL E-04

35 PRO-FLO X AIR DISTRIBUTION SYSTEM (ADS) DISASSEMBLY Step 7. Figure 7 Remove the air chamber and inspect air chamber gaskets (2). Replace if necessary. Step 8. Figure 8 Remove the pilot spool from the center section. Step 9. Figure 9 With o-ring pick, gently remove the o- ring from the opposite side of the center hole cut on the spool. Gently remove the pilot spool from sleeve and inspect for nicks or gouges and other signs of wear. Replace pilot sleeve assembly or outer sleeve o-rings if necessary. During re-assembly never insert the pilot spool into the sleeve with the center cut side first, this end incorporates the urethane o-ring and will be damaged as it slides over the ports cut in the sleeve. NOTE: Seals should not be removed from pilot spool. Seals are not sold separately. Step 10. Figure 10 Once the air chambers have been removed, the square air valve nuts (6) may be removed or replaced if necessary. Step 11. Figure 11 Remove and inspect the shaft bushings (2) replace if necessary. Step 12. Figure 12 Inspect center block Glyd rings (2) for wear. If replacement is necessary, use an o-ring pick to remove the used Glyd rings then replace with genuine Wilden replacement parts. WIL E WILDEN PUMP & ENGINEERING, LLC

36 Section 7 REASSEMBLY HINTS & TIPS ASSEMBLY: Upon performing applicable maintenance to the air distribution system, the pump can now be reassembled. Please refer to the disassembly instructions for photos and parts placement. To reassemble the pump, follow the disassembly instructions in reverse order. The air distribution system needs to be assembled first, then the diaphragms and finally the wetted path. Please find the applicable torque specifications on this page. The following tips will assist in the assembly process. Lubricate air valve bore, center section shaft and pilot spool bore with NLGI grade 2 white EP bearing grease or equivalent. Clean the inside of the center section shaft bore to ensure no damage is done to new seals. A small amount NLGI grade 2 white EP bearing grease can be applied to the muffler and air valve gaskets to locate gaskets during assembly. Make sure that the exhaust port on the muffler plate is centered between the two exhaust ports on the center section. Stainless bolts should be lubed to reduce the possibility of seizing during tightening. Use a mallet to tamp lightly on the large clamp bands to seat the diaphragm before tightening. PRO-FLO MAXIMUM TORQUE SPECIFICATIONS Description of Part Pro-Flo Air Valve Bolts Air Chamber to Center Block Outer Piston, Ultra-Flex Outer Piston, Rubber & TPE Manifold to Liquid Chamber Liquid Chamber to Air Chamber Torque P N m (45 in-lbs) / PX N m (45 in-lbs) 27.1 N m (20 ft-lbs) 47.5 N m (35 ft-lbs) 81.3 N m (60 ft-lbs) 44.7 N m (33 ft-lbs) 44.7 N m (33 ft-lbs) SHAFT SEAL INSTALLATION: PRE-INSTALLATION Once all of the old seals have been removed, the inside of the groove should be cleaned to ensure no debris is left that may cause premature damage to the new seals. INSTALLATION The following tools can be used to aid in the installation of the new seals: Needle Nose Pliers Phillips Screwdriver Electrical Tape Wrap electrical tape around each leg of the needle nose pliers (heat shrink tubing may also be used). This is done to prevent damaging the inside surface of the new seal. With a new seal in hand, place the two legs of the needle nose pliers inside the seal ring. (See Figure A.) Open the pliers as wide as the seal diameter will allow, then with two fingers pull down on the top portion of the seal to form kidney bean shape. (See Figure B.) Lightly clamp the pliers together to hold the seal into the kidney shape. Be sure to pull the seal into as tight of a kidney shape as possible, this will allow the seal to travel down the bushing bore easier. With the seal clamped in the pliers, insert the seal into the bushing bore and position the bottom of the seal into the correct groove. Once the bottom of the seal is seated in the groove, release the clamp pressure on the pliers. This will allow the seal to partially snap back to its original shape. After the pliers are removed, you will notice a slight bump in the seal shape. Before the seal can be properly resized, the bump in the seal should be removed as much as possible. This can be done with either the Phillips screwdriver or your finger. With either the side of the screwdriver or your finger, apply light pressure to the peak of the bump. This pressure will cause the bump to be almost completely eliminated. Lubricate the edge of the shaft with NLGI grade 2 white EP bearing grease. Slowly insert the center shaft with a rotating motion. This will complete the resizing of the seal. Perform these steps for the remaining seal. Figure A SHAFT SEAL Figure B NEEDLE NOSE PLIERS TAPE SHAFT SEAL TAPE WILDEN PUMP & ENGINEERING, LLC 34 WIL E-04

37 E L A S T O M E R K I T S Program Details: Elastomer & ADS Repair Kits All Sizes Available PTFE, Rubber & TPE Elastomers One Part Number Simplifies Inventory Eliminates Order Errors Reduces Re-Build Time Rejuvenates Your Pump NOTE: See Section 9.

P400/PX400. Advanced Series METAL Pumps. Advance your process. Engineering Operation & Maintenance WIL E-07 REPLACES WIL E-06

P400/PX400. Advanced Series METAL Pumps. Advance your process. Engineering Operation & Maintenance WIL E-07 REPLACES WIL E-06 P400/PX400 Advanced Series METAL Pumps Engineering Operation & Maintenance Advance your process WIL-11210-E-07 REPLACES WIL-11210-E-06 TABLE OF CONTENTS SECTION 1 CAUTIONS READ FIRST!..............................................1

More information

EOM PX1500. Engineering Operation & Maintenance. Advanced Series Metal Pump. WIL E-10 Replaces WIL E-09

EOM PX1500. Engineering Operation & Maintenance. Advanced Series Metal Pump.  WIL E-10 Replaces WIL E-09 EOM Engineering Operation & Maintenance PX1500 Advanced Series Metal Pump W h e r e I n n o v a t i o n F l o w s. www.wildenpump.com WIL-11230-E-10 Replaces WIL-11230-E-09 TABLE OF CONTENTS SECTION 1

More information

P400/PX400. Advanced Series METAL Pumps. Advance your process. Engineering Operation & Maintenance WIL E-12 REPLACES WIL E-11

P400/PX400. Advanced Series METAL Pumps. Advance your process. Engineering Operation & Maintenance WIL E-12 REPLACES WIL E-11 P400/PX400 Advanced Series METAL Pumps Engineering Operation & Maintenance Advance your process WIL-11210-E-12 REPLACES WIL-11210-E-11 TABLE OF CONTENTS SECTION 1 CAUTIONS READ FIRST!..............................................1

More information

P800/PX800. Advanced Series METAL Pumps. Advance your process. Engineering Operation & Maintenance WIL E-12 REPLACES WIL E-11

P800/PX800. Advanced Series METAL Pumps. Advance your process. Engineering Operation & Maintenance WIL E-12 REPLACES WIL E-11 P800/PX800 Advanced Series METAL Pumps Engineering Operation & Maintenance Advance your process WIL-11220-E-12 REPLACES WIL-11220-E-11 TABLE OF CONTENTS SECTION 1 CAUTIONS READ FIRST!..............................................1

More information

P8/PX8. Original Series PLASTIC Pumps. Simplify your process. Engineering Operation & Maintenance WIL E-04 TO REPLACE WIL E-03

P8/PX8. Original Series PLASTIC Pumps. Simplify your process. Engineering Operation & Maintenance WIL E-04 TO REPLACE WIL E-03 P8/PX8 Original Series PLASTIC Pumps Engineering Operation & Maintenance Simplify your process WIL-10131-E-04 TO REPLACE WIL-10131-E-03 TABLE OF CONTENTS SECTION 1 CAUTIONS READ FIRST!..............................................1

More information

PX1500. Advanced Series METAL Pumps. Advance your process. Engineering Operation & Maintenance. WIL E-02 Replaces WIL E-01

PX1500. Advanced Series METAL Pumps. Advance your process. Engineering Operation & Maintenance. WIL E-02 Replaces WIL E-01 PX1500 Advanced Series METAL Pumps Engineering Operation & Maintenance Advance your process WIL-11230-E-02 Replaces WIL-11230-E-01 TABLE OF CONTENTS SECTION 1 CAUTIONS READ FIRST!..............................................1

More information

P4/PX4. Original Series METAL Pumps. Simplify your process. Engineering Operation & Maintenance. WIL E-07 Replaces WIL E-06

P4/PX4. Original Series METAL Pumps. Simplify your process. Engineering Operation & Maintenance. WIL E-07 Replaces WIL E-06 P4/PX4 Original Series METAL Pumps Engineering Operation & Maintenance Simplify your process WIL-10310-E-07 Replaces WIL-10310-E-06 TABLE OF CONTENTS SECTION 1 CAUTIONS READ FIRST!..............................................1

More information

EOM P800/PX800. Advanced Series METAL Pumps. Advance your process. Engineering Operation & Maintenance WIL E-04 REPLACES WIL E-03

EOM P800/PX800. Advanced Series METAL Pumps. Advance your process. Engineering Operation & Maintenance WIL E-04 REPLACES WIL E-03 P800/PX800 Advanced Series METAL Pumps EOM Engineering Operation & Maintenance Advance your process WIL-11220-E-04 REPLACES WIL-11120-E-03 TABLE OF CONTENTS SECTION 1 CAUTIONS READ FIRST!..............................................1

More information

P800/PX800. Advanced Series METAL Pumps. Advance your process. Engineering Operation & Maintenance WIL E-05 REPLACES WIL E-04

P800/PX800. Advanced Series METAL Pumps. Advance your process. Engineering Operation & Maintenance WIL E-05 REPLACES WIL E-04 P800/PX800 Advanced Series METAL Pumps Engineering Operation & Maintenance Advance your process WIL-11220-E-05 REPLACES WIL-11220-E-04 TABLE OF CONTENTS SECTION 1 CAUTIONS READ FIRST!..............................................1

More information

PX4 P L A S T I C PX4 PERFORMANCE WIL T-02

PX4 P L A S T I C PX4 PERFORMANCE WIL T-02 PX4 P L A S T I C PX4 PERFORMANCE WIL-10161-T-02 Section 5B Pro-Flo X TM Operating Principal The Pro-Flo X air distribution system with the revolutionary Efficiency Management System (EMS) offers flexibility

More information

PX1 PX1 PERFORMANCE M E T A L WIL T-12

PX1 PX1 PERFORMANCE M E T A L WIL T-12 PX1 M E T A L PX1 PERFORMANCE WIL-10300-T-12 Pro-Flo X TM Operating Principal The Pro-Flo X air distribution system with the revolutionary Efficiency Management System (EMS) offers flexibility never before

More information

OPERATION MANUAL. ALUMINUM Models 316 S.S. Models AIR-OPERATED DOUBLE DIAPHRAGM PUMPS

OPERATION MANUAL. ALUMINUM Models 316 S.S. Models AIR-OPERATED DOUBLE DIAPHRAGM PUMPS OPERATION MANUAL 2 METALLIC PUMP (BOLTED) PWR-FLO TM AIR DISTRIBUTION SYSTEM NPF50 AIR-OPERATED DOUBLE DIAPHRAGM PUMPS ALUMINUM Models 316 S.S. Models A JDA Global Company CAUTIONS - READ FIRST CAUTION:

More information

P400/PX400. Advanced Series PLASTIC Pumps. Advance your process. Engineering Operation & Maintenance WIL E-02 TO REPLACE WIL E-01

P400/PX400. Advanced Series PLASTIC Pumps. Advance your process. Engineering Operation & Maintenance WIL E-02 TO REPLACE WIL E-01 P400/PX400 Advanced Series PLASTIC Pumps Engineering Operation & Maintenance Advance your process WIL-11240-E-02 TO REPLACE WIL-11240-E-01 TABLE OF CONTENTS SECTION 1 CAUTIONS READ FIRST!.............................................1

More information

EOM PX4. Engineering Operation & Maintenance. Saniflo Hygienic Series Metal Pumps. WIL E-04 TO REPLACE WIL E-03

EOM PX4. Engineering Operation & Maintenance. Saniflo Hygienic Series Metal Pumps.  WIL E-04 TO REPLACE WIL E-03 EOM Engineering Operation & Maintenance PX4 Saniflo Hygienic Series Metal Pumps W h e r e I n n o v a t i o n F l o w s www.wildenpump.com WIL-12300-E-04 TO REPLACE WIL-12300-E-03 TABLE OF CONTENTS SECTION

More information

PX400 P L A S T I C PX400 PERFORMANCE WIL T-02

PX400 P L A S T I C PX400 PERFORMANCE WIL T-02 PX400 P L A S T I C PX400 PERFORMANCE WIL-11240-T-02 Section 5B Pro-Flo X TM Operating Principal The Pro-Flo X air distribution system with the revolutionary Efficiency Management System (EMS) offers flexibility

More information

PX800 M E T A L PX800 PERFORMANCE WIL T-08

PX800 M E T A L PX800 PERFORMANCE WIL T-08 PX800 M E T A L PX800 PERFORMANCE WIL-11220-T-08 Section 5B Pro-Flo X TM Operating Principal The Pro-Flo X air distribution system with the revolutionary Efficiency Management System (EMS) offers flexibility

More information

EOM. PX2 Saniflo Hygienic Series Metal Pumps. Engineering Operation & Maintenance. WIL E-06 REPLACES WIL E-05

EOM. PX2 Saniflo Hygienic Series Metal Pumps. Engineering Operation & Maintenance.  WIL E-06 REPLACES WIL E-05 EOM Engineering Operation & Maintenance PX2 Saniflo Hygienic Series Metal Pumps W h e r e I n n o v a t i o n F l o w s www.wildenpump.com WIL-12330-E-06 REPLACES WIL-12330-E-05 TABLE OF CONTENTS SECTION

More information

EOM PX15. Engineering Operation & Maintenance. Saniflo Hygienic Series Metal Pumps. WIL E-04 TO REPLACE WIL E-03

EOM PX15. Engineering Operation & Maintenance. Saniflo Hygienic Series Metal Pumps.  WIL E-04 TO REPLACE WIL E-03 EOM Engineering Operation & Maintenance PX15 Saniflo Hygienic Series Metal Pumps W h e r e I n n o v a t i o n F l o w s www.wildenpump.com WIL-12320-E-04 TO REPLACE WIL-12320-E-03 TABLE OF CONTENTS SECTION

More information

EOM PX2. Engineering Operation & Maintenance. Saniflo Hygienic Series. WIL E-05 TO REPLACE WIL E-04

EOM PX2. Engineering Operation & Maintenance. Saniflo Hygienic Series.  WIL E-05 TO REPLACE WIL E-04 EOM Engineering Operation & Maintenance PX2 Saniflo Hygienic Series Metal Pumps W h e r e I n n o v a t i o n F l o w s www.wildenpump.com WIL-12330-E-05 TO REPLACE WIL-12330-E-04 TABLE OF CONTENTS SECTION

More information

PX4. Original Series PLASTIC Pumps. Simplify your process. Engineering Operation & Maintenance WIL E-02 TO REPLACE WIL E-01

PX4. Original Series PLASTIC Pumps. Simplify your process. Engineering Operation & Maintenance WIL E-02 TO REPLACE WIL E-01 PX4 Original Series PLASTIC Pumps Engineering Operation & Maintenance Simplify your process WIL-10161-E-02 TO REPLACE WIL-10161-E-01 TABLE OF CONTENTS SECTION 1 CAUTIONS READ FIRST!............................................

More information

EOM. PX420 / PX430 Advanced FIT Metal Pumps. Engineering Operation & Maintenance. REPLACES WIL E-01

EOM. PX420 / PX430 Advanced FIT Metal Pumps. Engineering Operation & Maintenance.   REPLACES WIL E-01 EOM Engineering Operation & Maintenance PX420 / PX430 Advanced FIT Metal Pumps W h e r e I n n o v a t i o n F l o w s www.wildenpump.com WIL-11530-E-02 REPLACES WIL-11530-E-01 TABLE OF CONTENTS SECTION

More information

P1/PX1. Original Series METAL Pumps. Simplify your process. Engineering Operation & Maintenance LISTED 79 WIL E-15 REPLACES WIL E-14

P1/PX1. Original Series METAL Pumps. Simplify your process. Engineering Operation & Maintenance LISTED 79 WIL E-15 REPLACES WIL E-14 P1/PX1 Original Series METAL Pumps Engineering Operation & Maintenance Simplify your process LISTED 79 WIL-10300-E-15 REPLACES WIL-10300-E-14 TABLE OF CONTENTS SECTION 1 CAUTIONS READ FIRST!..............................................1

More information

EOM PX8. Sanifl o Hygienic Series METAL Pumps. Refine your process. Engineering Operation & Maintenance WIL E-01

EOM PX8. Sanifl o Hygienic Series METAL Pumps. Refine your process. Engineering Operation & Maintenance WIL E-01 PX8 Sanifl o Hygienic Series METAL Pumps EOM Engineering Operation & Maintenance Refine your process WIL-12310-E-01 TABLE OF CONTENTS SECTION 1 CAUTIONS READ FIRST!..............................................1

More information

EOM. P1/PX1 Original Series Metal Pump. Engineering Operation & Maintenance. WIL E-16 REPLACES WIL E-15

EOM. P1/PX1 Original Series Metal Pump. Engineering Operation & Maintenance.   WIL E-16 REPLACES WIL E-15 EOM Engineering Operation & Maintenance P1/PX1 Original Series Metal Pump W h e r e I n n o v a t i o n F l o w s www.wildenpump.com WIL-10300-E WIL-10300-E-16 REPLACES WIL-10300-E-15 TABLE OF CONTENTS

More information

OPERATION MANUAL AIR-OPERATED DOUBLE DIAPHRAGM PUMPS 1.5 POLYPROPYLENE PUMP PWR-FLO TM AIR DISTRIBUTION SYSTEM NPF40 CLAMPED. A JDA Global Company

OPERATION MANUAL AIR-OPERATED DOUBLE DIAPHRAGM PUMPS 1.5 POLYPROPYLENE PUMP PWR-FLO TM AIR DISTRIBUTION SYSTEM NPF40 CLAMPED. A JDA Global Company OPERATION MANUAL 1.5 POLYPROPYLENE PUMP PWR-FLO TM AIR DISTRIBUTION SYSTEM NPF40 CLAMPED AIR-OPERATED DOUBLE DIAPHRAGM PUMPS A JDA Global Company CAUTIONS - READ FIRST CAUTION: Do not apply compressed

More information

PX1510. Advanced Series METAL Pumps. Advance your process. Engineering Operation & Maintenance WIL E-01

PX1510. Advanced Series METAL Pumps. Advance your process. Engineering Operation & Maintenance WIL E-01 PX1510 Advanced Series METAL Pumps Engineering Operation & Maintenance Advance your process WIL-11270-E-01 TABLE OF CONTENTS SECTION 1 CAUTIONS READ FIRST!..............................................1

More information

PX810. Advanced Series METAL Pumps. Advance your process. Engineering Operation & Maintenance WIL E-01

PX810. Advanced Series METAL Pumps. Advance your process. Engineering Operation & Maintenance WIL E-01 PX810 Advanced Series METAL Pumps Engineering Operation & Maintenance Advance your process WIL-11280-E-01 TABLE OF CONTENTS SECTION 1 CAUTIONS READ FIRST!..............................................1

More information

AIR-OPERATED DOUBLE DIAPHRAGM PUMP USER S MANUAL

AIR-OPERATED DOUBLE DIAPHRAGM PUMP USER S MANUAL 00, 0, 000 00, 000, 00 A. TECHNICAL INFORMATION Model 00 Inlet/Outlet " Air Inlet /" 0 / 000 /" /" 00 /" /" 000 /" /" 00 /" /" Flow Rate GPM/ 0LPM GPM/ 0LPM GPM/ LPM GPM/ LPM GPM/ 0LPM GPM/ 0LPM Maximum

More information

S a n i f l o S E R I E S R e f i n e y o u r p r o c e s s

S a n i f l o S E R I E S R e f i n e y o u r p r o c e s s Saniflo S E R I E S R e f i n e y o u r p r o c e s s Saniflo S E R I E S Your Needs Must be easy to clean & inspect Does not damage my product Minimize my water usage Maximize my reliability & efficiency

More information

OPERATOR S MANUAL

OPERATOR S MANUAL OPERATOR S MANUAL 1604619 INCLUDING: OPERATION, INSTALLATION & MAINTENANCE RELEASED: 11-1-13 REVISED: 3-03-14 (REV. B) 1/4" DIAPHRAGM PUMP 1:1 RATIO (NON-METALLIC) 1604628 READ THIS MANUAL CAREFULLY BEFORE

More information

A050-1/2 INCH AIR OPERATED double DIAPHRAGM PUMP

A050-1/2 INCH AIR OPERATED double DIAPHRAGM PUMP A050 - /2 INCH AIR OPERATED double DIAPHRAGM PUMP A050 /2 Pump /2 Aluminum NPT or BSP Connections Zinc Plated Hardware Non-Metallic Muffler Suction Right / Discharge Right Standard Porting SPECIFICATIONS

More information

XSD HS. Saniflo Hygienic Series Surge Dampener. Refine your process. Engineering Operation & Maintenance WIL E-01

XSD HS. Saniflo Hygienic Series Surge Dampener. Refine your process. Engineering Operation & Maintenance WIL E-01 XSD HS Saniflo Hygienic Series Surge Dampener Engineering Operation & Maintenance Refine your process WIL-12230-E-01 TABLE OF CONTENTS SECTION 1 CAUTIONS READ FIRST!.............................................1

More information

2 I All-Flo Pump Co.

2 I All-Flo Pump Co. 2 I All-Flo Pump Co. 3I All-Flo Pump Co. Model Designation Matrix PRODUCT SERIES PUMP SIZE FLUID CONNECTI INTERM INNER CHAM ON TYPE FLUID C HAMBER MANIFOLDS EDI A TE/ BER O-RINGS VAL VE SEAT VALVE/BAL

More information

TECHNICAL DATA Q= C. Table 1 - Specifications

TECHNICAL DATA Q= C. Table 1 - Specifications September 25, 2013 Pressure Regulation 537a 1. Description The Model B-3 Pilot Operated Pressure Control Valve is a factory assembled unit. The unit consists of a Model J-2 Halar coated Flow Control Valve,

More information

2 I All-Flo Pump Co.

2 I All-Flo Pump Co. 2 I All-Flo Pump Co. 3I All-Flo Pump Co. Model Designation Matrix Pump Dimensions A B C D F H I J K L P300 18.90" 22.83" 31.50" 3.94" 15.28" 27.17" 1.57" 2.95" 15.55" 19.49" (480 mm) (580 mm) (800 mm)

More information

OWNER S TECHNICAL MANUAL

OWNER S TECHNICAL MANUAL EL SERIES OWNER S TECHNICAL MANUAL DP7002 1 Air Operated Diaphragm Pump Description The DP7002 1 air operated diaphragm pump is the ideal device for the pumping, transfer and dispensing of chemical liquids,

More information

ACCU-PULSE Installation and Operation Instructions

ACCU-PULSE Installation and Operation Instructions ACCU-PULSE Installation and Operation Instructions Pump Discharge Installation: Chargeable Models Step 1: Mounting Position Mount ACCU-PULSE as close to the pump discharge as possible to absorb the pulse

More information

TECHNICAL DATA. the Viking Pilot Pressure Regulating Valve 1 Model A-1 Speed Control Assembly: OBSOLETE. the Viking Speed Control Assembly 1

TECHNICAL DATA. the Viking Pilot Pressure Regulating Valve 1 Model A-1 Speed Control Assembly: OBSOLETE. the Viking Speed Control Assembly 1 November 30, 1994 534 a 1. PRODUCT NAME VIKING 2" (50mm), 3" (75mm), 4" (100mm), 6" (150mm) 2. MANUFACTURER THE VIKING CORPORATION 210 N. Industrial Park Road Hastings, Michigan 49058 U.S.A. Telephone:

More information

Air Amplifiers & SYSTEMS

Air Amplifiers & SYSTEMS Air Amplifiers & SYSTEMS We Accept VISA, MasterCard and American Express Air Amplifiers Point-of-Use Air Solutions Maximator air amplifiers are designed to boost plant air pressure or increase the supply

More information

TECHNICAL DATA. Table 1 - Specifications

TECHNICAL DATA. Table 1 - Specifications Page 1 of 6 1. DESCRIPTION Model A-3 Pilot Operated Pressure Control Valves are factory assembled units. Each unit consists of a Model H-2 Halar coated Flow Control Valve, a Speed Control Valve, a Model

More information

FAST & FLEXIBLE EXPERTISE 100% ORDER FULFILLMENT LOW COST PROVIDER

FAST & FLEXIBLE EXPERTISE 100% ORDER FULFILLMENT LOW COST PROVIDER FAST & FLEXIBLE JDA Global LLC (EST. 0) serves as the world s largest & most experienced after-market diaphragm pump products provider. We leverage our deeply embedded industry knowledge each day to bring

More information

COMBINATION AIR RELEASE DEGASSING (CARD) VALVES INSTALLATION AND MAINTENANCE MANUAL

COMBINATION AIR RELEASE DEGASSING (CARD) VALVES INSTALLATION AND MAINTENANCE MANUAL COMBINATION AIR RELEASE DEGASSING (CARD) VALVES INSTALLATION AND MAINTENANCE MANUAL SPECIFICATIONS: The CARD series air valves are available in 3 pipe sizes, 1, 2 and 4 NPT or socket. Maximum inlet pressure

More information

SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER

SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER SUPPLIMENT TO eom IMPORTANT READ THIS MANUAL BEFORE PRODUCT INSTALLATION, OPERATION, INSPECTION & MAINTENANCE Tougher and more rigid guidelines are being established

More information

TECHNICAL DATA. Page 1 of 12

TECHNICAL DATA. Page 1 of 12 Page 1 of 12 1. DESCRIPTION The Viking Regulating Valve is a direct-acting, single-seated, spring-loaded diaphragm valve. When installed as a pilot regulating valve on a Viking Model H or J Flow Control

More information

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator. RS(H)10,15 USER MANUAL Read the complete manual before installing and using the regulator. WARNING INCORRECT OR IMPROPER USE OF THIS PRODUCT CAN CAUSE SERIOUS PERSONAL INJURY AND PROPERTY DAMAGE. Due to

More information

AN ISO 9001 COMPANY. Diaphragm Pump. DPB - 75 ALB Aluminium Buna N. Operation & Maintenance Guide. Sheet 1 of 10 FF - MM - 96 REV - 3

AN ISO 9001 COMPANY. Diaphragm Pump. DPB - 75 ALB Aluminium Buna N. Operation & Maintenance Guide. Sheet 1 of 10 FF - MM - 96 REV - 3 AN ISO 9001 COMPANY Diaphragm Pump DPB - 75 ALB Aluminium Buna N Operation & Maintenance Guide Sheet 1 of 10 Diaphragm Pump DPB-75 ALB Operation & Maintenance Guide Common Nomenclature for DP/DPB Series

More information

LRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator.

LRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator. LRS(H)4 USER MANUAL Read the complete manual before installing and using the regulator. WARNING INCORRECT OR IMPROPER USE OF THIS PRODUCT CAN CAUSE SERIOUS PERSONAL INJURY AND PROPERTY DAMAGE. Due to the

More information

Self-priming makes priming unnecessary Exhausts the air inside the suction pipe to suck up liquid. Air operated type.

Self-priming makes priming unnecessary Exhausts the air inside the suction pipe to suck up liquid. Air operated type. Process Pump Series 3/5 Automatically Operated Type (Internal Switching Type)/Air Operated Type (External Switching Type) High abrasion resistance and low particle generation o sliding parts in wetted

More information

TECHNICAL DATA. Pressure Regulation 531a. April 24, 2009

TECHNICAL DATA. Pressure Regulation 531a. April 24, 2009 April 24, 29 Pressure Regulation 531a 1. DESCRIPTION The Viking Regulating Valve is a direct-acting, single-seated, spring-loaded diaphragm valve. When installed as a pilot regulating valve on a Viking

More information

Bermad Pressure Reducing. Model: 42T

Bermad Pressure Reducing. Model: 42T Bermad Pressure Reducing Pilot Operated Pressure Control Valve Model: 42T Installation Operation Maintenance Manual (IOM) REV. 27.7.17 Page 1 of 12 Safety First BERMAD believes that the safety of personnel

More information

The Shand & Jurs Model Vapor Guard Tank Blanketing Valve

The Shand & Jurs Model Vapor Guard Tank Blanketing Valve Lower maintenance due to fewer parts Occupies less space, less stress to tank Teflon is inert to most chemicals; extends service life Simplifies and lowers maintenance cost Optimizes flow of blanketing

More information

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S Page 1 of 13 1. DESCRIPTION The Viking 6 Model G-6000 Dry Valve Riser Assembly consists of a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry sprinkler

More information

DataSheet. Series AA Electronic Metering Pumps. Configuration Data. Dimensions. Specifications. Model AA HI. ISO 9001 Certified

DataSheet. Series AA Electronic Metering Pumps. Configuration Data. Dimensions. Specifications. Model AA HI. ISO 9001 Certified DataSheet Series AA Electronic Metering Pumps Configuration Data Model AA 9 4 1-358HI Control Code 1 --- Manual Control: Speed (stroking frequency) and stroke length manually adjustable. 7 --- Instrument

More information

PULSATION DAMPENER / SUPPRESSOR SERIES PDS PROVIDES MULTIPLE SYSTEM SAFEGUARDS

PULSATION DAMPENER / SUPPRESSOR SERIES PDS PROVIDES MULTIPLE SYSTEM SAFEGUARDS PULSATION / SUPPRESSOR SERIES PDS PROVIDES MULTIPLE SYSTEM SAFEGUARDS FUNCTIONS: 1. Pulsation Dampener smooths pump flow 2. Surge Suppressor absorbs shocks and vibrations 3. Water Hammer Arrestor eliminates

More information

I T T Pressure Reducing Valve WARNING INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

I T T Pressure Reducing Valve WARNING INSTALLATION, OPERATION, AND MAINTENANCE MANUAL INSTALLATION, OPERATION, AND MAINTENANCE MANUAL I-867-4T 867-4T Pressure Reducing Valve HANG THESE INSTRUCTIONS ON THE INSTALLED VALVE FOR FUTURE REFERENCE WARNING Read and understand all instructions

More information

SERIES 30. Spring Operated Tank Blanketing Valve PROTECTOSEAL.

SERIES 30. Spring Operated Tank Blanketing Valve PROTECTOSEAL. SERIES 30 PROTECTOSEAL 1 2" NPT inlet and outlet standard Direct acting valve mechanism Optional flanged or threaded inlet and outlet connections available Inlet gas pressures from 10 PSIG to 200 PSIG

More information

Discharge Relief Valve Operation & Maint.

Discharge Relief Valve Operation & Maint. Relief Valve Operation & Maint. CZ Series Centrifugal Fire Relief svalve Operation and Maintenance Instructions 1410 Operation and Maintenance Form No. F-1031 Section 2302.6 2111 Issue Date 04/90 11/95

More information

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator. PRS(TC)4,8 USER MANUAL Read the complete manual before installing and using the regulator. WARNING INCORRECT OR IMPROPER USE OF THIS PRODUCT CAN CAUSE SERIOUS PERSONAL INJURY AND PROPERTY DAMAGE. Due to

More information

Model GP PRESSURE REDUCING VALVE Installation & Operation Manual

Model GP PRESSURE REDUCING VALVE Installation & Operation Manual Model GP-2000 PRESSURE REDUCING VALVE Installation & Operation Manual Please read this bulletin thoroughly before using the pressure reducing valve, so that you may do so correctly and safely. Please carefully

More information

Pressure on Demand. Air Pressure Amplifiers

Pressure on Demand. Air Pressure Amplifiers Pressure on Demand Air Pressure Amplifiers Introduction Haskel air pressure amplifiers offer the most comprehensive range in the industry combining simple principles of operation with rugged construction

More information

94270 Vapor Guard Tank Blanketing Valve Vapor Guard Tank Blanketing Valve What is Tank Blanketing? Features How does it work?

94270 Vapor Guard Tank Blanketing Valve Vapor Guard Tank Blanketing Valve What is Tank Blanketing? Features How does it work? 94270 What is Tank Blanketing? blanketing systems are used to prevent the escape of liquid vapors into the atmosphere or to prevent moisture from entering a tank and contaminating its contents. A tank

More information

Reduce pressure zone device suitable for high and medium hazard rated applications Flanged end connections

Reduce pressure zone device suitable for high and medium hazard rated applications Flanged end connections VALVCHEQ Backflow Preventers Reduce pressure zone device suitable for high and medium hazard rated applications Flanged end connections Features General application The RP03 provides protection from both

More information

PumpAgents.com - Click here for Pricing/Ordering Nominal psi (bar) Cut-In Cut-Out

PumpAgents.com - Click here for Pricing/Ordering Nominal psi (bar) Cut-In Cut-Out PumpAgents.com - Click here for Pricing/Ordering Model 31670-Series Dual Max 7.5 GPM (28 LPM) AUTOMATIC TWO STAGE WATER SYSTEM WITH ACCUMULATOR TANK AND PUMPGARD STRAINER IDEAL FOR PLEASURE AND COMMERCIAL

More information

FILTER BYPASS CONTROL

FILTER BYPASS CONTROL Differential Control Valve Series 110 The Series 110 Differential Control Valve is designed to accurately control the pressure difference between any two points. In some systems this means the valve remains

More information

VALVCHEQ BACKFLOW PREVENTERS FIGURE RP03

VALVCHEQ BACKFLOW PREVENTERS FIGURE RP03 Reduce pressure zone device suitable for high and medium hazard rated applications Flanged end connections FEATURES GENERAL APPLICATION The RP03 provides protection from both backsiphonage and backpressure

More information

RHPS Series RD(H)F40 User Manual. Read the complete manual before installing and using the regulator.

RHPS Series RD(H)F40 User Manual. Read the complete manual before installing and using the regulator. RHPS Series RD(H)F40 User Manual Read the complete manual before installing and using the regulator. 2 WARNING Before removing a regulator from the system for service, you must depressurize system purge

More information

Model: 720-UL INSTALLATION OPERATION MAINTENANCE. Bermad Pressure Reducing Valve IOM. Model: FP -720-UL Sizes: 2"-12" BERMAD. Application Engineering

Model: 720-UL INSTALLATION OPERATION MAINTENANCE. Bermad Pressure Reducing Valve IOM. Model: FP -720-UL Sizes: 2-12 BERMAD. Application Engineering Bermad Pressure Reducing Valve Model: 720-UL INSTALLATION OPERATION MAINTENANCE Application Engineering BERMAD 1. Safety First BERMAD believes that the safety of personnel working with and around our equipment

More information

TECHNICAL DATA CAUTION

TECHNICAL DATA CAUTION Page 1 of 12 1. DESCRIPTION The Viking Model C-2 Pilot Pressure Regulating Valve is a direct-acting, single-seated, spring-loaded diaphragm valve. When installed as a pilot regulating valve on a Viking

More information

Model: 43T. Bermad Pressure Relief Valve

Model: 43T. Bermad Pressure Relief Valve Model: 43T Bermad Pressure Relief Valve Installation Operation Maintenance Manual () Rev.C1_01.08.17 Page 1 of 10 Safety First BERMAD believes that the safety of personnel working with and around our equipment

More information

BACK PRESSURE / SUSTAINING

BACK PRESSURE / SUSTAINING In many liquid piping systems, it is vital that line pressure is maintained within relatively narrow limits. This is the function of the 108 Pressure Relief / Back Pressure Series of the OCV control valves.

More information

A CATALOUGE FOR Q B Y AIR OPERATION DIAPHRAGM PUMP. Factory Warranty. Food & Beverage. Mining. Paints & Dyes. Petrochemical.

A CATALOUGE FOR Q B Y AIR OPERATION DIAPHRAGM PUMP. Factory Warranty. Food & Beverage. Mining. Paints & Dyes. Petrochemical. Catalogue No. SIKO-QBY-003 A CATALOUGE FOR Q B Y AIR OPERATION DIAPHRAGM PUMP 1 Full Year Factory Warranty Food & Beverage Mining Paints & Dyes Petrochemical Pharmaceutical Pulp & Paper Power & Energy

More information

INSTALLATION, OPERATION AND MAINTENANCE GUIDE

INSTALLATION, OPERATION AND MAINTENANCE GUIDE INSTALLATION, OPERATION AND Placement in Pipeline System When installing Process Development & Control s ElastoTITE Elastomer-Hinged Check Valves in a pipeline, a minimum of five pipe diameters should

More information

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY Page 1 of 13 1. DESCRIPTION The Viking 3 Model G-3000 Dry Valve Riser Assembly is equipped with a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry

More information

Type S301 & S302 Gas Regulators INTRODUCTION INSTALLATION. Scope of Manual. Description. Specifications. Type S301 and S302. Instruction Manual

Type S301 & S302 Gas Regulators INTRODUCTION INSTALLATION. Scope of Manual. Description. Specifications. Type S301 and S302. Instruction Manual Fisher Controls Instruction Manual Type S301 & S302 Gas Regulators October 1981 Form 5180 WARNING Fisher regulators must be installed, operated, and maintained in accordance with federal, state, and local

More information

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13 Page 1 of 13 1. Description The Viking 2 Model G-2000 Dry Valve Riser Assembly consists of a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry sprinkler

More information

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S January 6, 2012 Preaction 333a 1. Description Viking supervised Surefire Preaction Systems Utilize the Viking G-3000P Valve. The small profile, lightweight, pilot-operated Viking G-3000P Valve comes complete

More information

BACK PRESSURE / SUSTAINING

BACK PRESSURE / SUSTAINING SPECIFICATIONS DIMENSIONS In many liquid piping systems, it is vital that line pressure is maintained within relatively narrow limits. This is the function of the 108 Pressure Relief / Back Pressure Series

More information

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly. Components preparation and pressure adjustment ABP Overview ABP is a component that enables boosting by s only up to twice primary pressure (.0MPa max.) in combination with using air tank but not using

More information

HAYWARD FLOW CONTROL Series PBV Back Pressure Valve and Series RPV Pressure Relief Valve INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS

HAYWARD FLOW CONTROL Series PBV Back Pressure Valve and Series RPV Pressure Relief Valve INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS HAYWARD FLOW CONTROL Series PBV Back Pressure Valve and Series RPV Pressure Relief Valve INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS Page 1 of 20 Page 2 of 20 TABLE OF CONTENTS Safety Warnings

More information

Waterous Relief Valve

Waterous Relief Valve Operating Instructions 1. Reduce pump discharge pressure with engine throttle. Make sure four way (On/Off) valve is OFF. 2. Open at least one discharge valve. Accelerate engine until pressure gage indicates

More information

BS Series Basket Strainer

BS Series Basket Strainer BS Series Basket Strainer Operating, Installation, & Maintenance Manual Corrosion Resistant Fluid and Air Handling Systems. Dated 04-26-12 PRESSURE DROP SIMTECH strainers are engineered to offer the lowest

More information

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S January 6, 2012 Preaction 348a 1. Description Viking supervised Surefire Preaction Systems utilize the Viking G-6000P Valve. The small profile, lightweight, pilot operated Viking G-6000P Valve comes complete

More information

Rate of Flow Valve Series 120

Rate of Flow Valve Series 120 SPECIFICATIONS Rate of Flow Valve Series DIMENSIONS The OCV Series 120 Rate of Flow control valve is designed to control or limit flow to a predetermined rate, regardless offl uctuations in downstream

More information

Process Pump Automatically Operated Type (Internal Switching Type) Air Operated Type (External Switching Type) How to Order

Process Pump Automatically Operated Type (Internal Switching Type) Air Operated Type (External Switching Type) How to Order Process Pump /5 Series Automatically Operated Type (Internal Switching Type)/Air Operated Type (External Switching Type) High abrasion resistance and low particle generation o sliding parts in wetted areas.

More information

HYDRAULIC INTENSIFIER Max. Pressure: See Intensifier Data Plate Weight: 16 Lbs. (7.26 kg)

HYDRAULIC INTENSIFIER Max. Pressure: See Intensifier Data Plate Weight: 16 Lbs. (7.26 kg) Form No. 102897 Operating Instructions for: HB443 HB444 HYDRAULIC INTENSIFIER Max. Pressure: See Intensifier Data Plate Weight: 16 Lbs. (7.26 kg) Definition: A devise that raises the inlet pressure to

More information

DANFLO Control Valves 400 Series Model 20

DANFLO Control Valves 400 Series Model 20 DANFLO Control Valves 400 Series Model 20 Back Pressure/Pressure Relief The DANFLO Model 20 is a pilot operated valve suitable for use in gas or liquid facilities and requires no outside power for operation.

More information

TECHNICAL DATA. Q= Cv S

TECHNICAL DATA. Q= Cv S Page 1 of 13 1. DESCRIPTION The Viking 4 inch Model G-4000 Dry Valve Riser Assembly consists of a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry

More information

Liquid Level Controllers

Liquid Level Controllers Liquid Level Controllers ALL PUMPS LLC-2Y For both pump up and down control. Variable On/Off set points. NDP-15/20/25/32, DP-10/15 & *NDP-40/50/80 LLC-1 Pump up and down versions available. 6 to 12 differential

More information

TOP VALVE. Pat. #5,857,486 & 5,944,050. High Temperature: max. 300 F (149 C) Back Pressure And Pressure Relief Valves. Instruction Manual

TOP VALVE. Pat. #5,857,486 & 5,944,050. High Temperature: max. 300 F (149 C) Back Pressure And Pressure Relief Valves. Instruction Manual TOP VALVE Pat. #5,857,486 & 5,944,050 High Temperature: max. 300 F (149 C) Back Pressure And Pressure Relief Valves Instruction Manual PLEASE NOTE: This instruction manual provides information and instructions

More information

ACCUMULATOR OPERATING & MAINTENANCE INSTRUCTIONS

ACCUMULATOR OPERATING & MAINTENANCE INSTRUCTIONS ACCUMULATOR OPERATING & MAINTENANCE INSTRUCTIONS READ ALL INSTRUCTIONS PRIOR TO INSTALLATION AND OPERATION TO AVOID POSSIBLE INJURY Warning: Always consider any accumulator to contain pressure until proven

More information

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S Preaction 346a 1. Description The 6 Model G-6000P Electric Release Preaction System Riser Assembly can be used as a Single Interlock Preaction System with Electric Release, or as a Double Interlock Preaction

More information

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S January 6, 2012 Preaction 347a 1. Description Viking supervised Double-Interlocked Electric/Pneumatic Release Preaction Systems utilize the Viking G-6000P Valve. The small profile, lightweight, pilot operated

More information

Combination Air Valve

Combination Air Valve Combination Air Valve For Sewage and Wastewater Model C50 Installation, Operation and Maintenance Manual (IOM) Table of Contents General... Page 2 Safety... Page 2 Operational Data... Page 3 Materials

More information

N2 Blanketing Valve DST100 / DST200 TYPE INSTRUCTION MANUAL CONTENTS K.S.P.C. General Description Operation. Installation Maintenance

N2 Blanketing Valve DST100 / DST200 TYPE INSTRUCTION MANUAL CONTENTS K.S.P.C. General Description Operation. Installation Maintenance DST100 / DST200 TYPE N2 Blanketing Valve INSTRUCTION MANUAL CONTENTS General Description Operation Installation Maintenance K.S.P.C 488-1 Wolha-ro, Tongjin-eup, Gimpo-si, Gyeonggi-Do, Korea Tel : +82-31-998-3825~7

More information

V43 Pressure Actuated Water Regulating Valve

V43 Pressure Actuated Water Regulating Valve FANs 125, 121 Product/Technical Bulletin V43 Issue Date 0996 V43 Pressure Actuated Water Regulating Valve The V43 Pressure Actuated Water Regulating Valves are designed to regulate water flow for water-cooled

More information

BUTTERFLY VALVES Series 800

BUTTERFLY VALVES Series 800 BUTTERFLY VALVES Series 800 WARNING Before proceeding read ALL instructions and become familiar with the equipment and associated drawings. Follow ALL applicable safety regulations and codes for pressurized

More information

Exercise 2-3. Flow Rate and Velocity EXERCISE OBJECTIVE C C C

Exercise 2-3. Flow Rate and Velocity EXERCISE OBJECTIVE C C C Exercise 2-3 EXERCISE OBJECTIVE C C C To describe the operation of a flow control valve; To establish the relationship between flow rate and velocity; To operate meter-in, meter-out, and bypass flow control

More information

OptiFlo Air operated double diaphragm pumps

OptiFlo Air operated double diaphragm pumps Instruction Manual OptiFlo Air operated double diaphragm pumps Read and understand this manual prior to operating or servicing this product. A.0200.401 IM-OF/04.00 EN (07/2009) EC Declaration of Conformity

More information

TECHNICAL DATA. TRIMPAC Model B-5 & B-5B

TECHNICAL DATA. TRIMPAC Model B-5 & B-5B September 16, 2013 Trimpac 250a 1. DESCRIPTION DEsCRIPTIoN is a factory assembled trim package for a ed an electric/pneumatic release module in a metal enclosure. The standard trim normally required on

More information

TITAN FLOW CONTROL, INC.

TITAN FLOW CONTROL, INC. PREFACE: This manual contains information concerning the installation, operation, and maintenance of Titan Flow Control (Titan FCI) Simplex Basket Strainers. To ensure efficient and safe operation of Titan

More information