The benefits of system solutions for valve users

Size: px
Start display at page:

Download "The benefits of system solutions for valve users"

Transcription

1 1/16 The benefits of system solutions for valve users 1. Introduction 2. System types 2.1. Pressure control 2.2. Temperature control 3. Technical process design 3.1. Checking of operating data 3.2. Selection of system type 3.3. Description and dimensioning using a pressure reducing station as an example 4. Documentation 5. Certification 6. Summary 7. Bibliography Pressure reducer PREDU Globe valves FABA / orifice plate Safety valve SAFE Strainer / seperator Steam trap CONA Other components

2 2/16 1. Introduction The correct functioning and right interplay of widely varying components e.g. valves in general installations, power plant stations, chemicals and petrochemicals and the processing industry, are essential for economical and smooth operation. The number of valves introduced runs from a few in small systems to several thousand in large and complex ones. These large systems must nevertheless be seen in respect of every detail not as a whole, but are able to be divided into individual subsystems. Since the functioning of these subsystems must also be able to be accurately and individually defined, it is possible to take these parts entirely out of the overall system and to project them on the basis of operating data to be accurately laid down. The planning department, which is responsible for the entire installation, is able to concentrate on the important main functions and so ensure that the overall position fulfils the actual principal task, for example energy conversion, or the production of a chemical base material. The detailed design and provisions of optimum coordination of individual components are the responsibility of the supplier of the subsystem. The subsystems can be delivered by the supplier in one of two different forms, depending on the position of incorporation, either as a complete assembly of the subsystem at the supplier s, or as components, which are then assembled at their destination. In either case, the subsystem is dimensioned by the supplier and the covering documents are created. 2. System types Standard systems for pressure and temperature control are set out below and can be varied individually as desired Pressure control A steam pressure reducing station without auxiliary energy is shown in Fig 1. Pressure control takes place via a special control valve, the pressure reducer PREDU (Pos. 1). This selfacting valve requires no auxiliary energy. For the operation of a pressure reducer, a series of other auxiliary and monitoring valves are required. The concept of "steam pressure reducing station" embraces all these components, including pipes. Two distinct sets of pipes are recognised, the main pipe divided into the upstream and downstream pipe, as well as the bypass pipe. The steam flows first of all through the upstream pipe, then the globe valve FABA (Pos. 4), the strainer (Pos. 5) and the steam trap (Pos. 3) before then reaching the pressure reducer. Following pressure reduction in the pressure reducer, it reaches a further globe valve (Pos. 6) in the downstream pipe to the station output, the safety valve SAFE (Pos. 2) being directly connected to this area. The nominal diameter of the pipe depends on the maximum admissible speed of flow.

3 3/16 Fig. 1: Steam pressure reducing station without auxiliary energy The exact dimensioning is described under point 3. Technical process design". On the admission of steam, the control pipe and the water seal pot (Pos. 7) must be filled with water. The diaphragm of the pressure reducer hanging downwards together with the actuator is thus protected from the high steam temperatures. The bypass pipe is required for the manual operation of the downstream system in the case of maintenance of the strainer and the pressure reducer. For this purpose, globe valves in front and behind the pressure reducer are closed and the globe valve in the bypass pipe (Pos. 8) is opened. Watching the manometer (Pos.10), the operation is to be maintained manually, with the safety valve performing the task of pressure protection in this case as well. In steam operation, condensate constantly forms in the pipes and must removed via the steam trap. Fig 1 clearly shows the diversion in the pressure pipe via the steam trap CONA -S (Pos. 13). The upper globe valve (Pos. 11) is normally open and is closed only in the case of a maintenance operation on the trap, the lower globe valve (Pos.14) being provided for the removal of sludge and is normally closed. Using the sight glass (Pos. 12) it is possible to observe the flow of condensate and thus to control the functioning of the trap. Condensate also forms in the downstream pipe. In particular in the case of a small flow and a almost closed pressure reducer, the condensate level can rise. In the case of a pressure reducer suddenly opened by increased output demand, water hammer occurs, which in principle is to be avoided. Fig. 1 shows the outflow using a bimetallic steam trap CONA -B (Pos. 17).

4 4/16 For controlling the reducing station, gauges in front and behind the pressure reducer are useful and the inlet pressure between the strainer and the pressure reducer should be measured, since a blockage of a strainer can be recognised by a pressure drop. For simplifying the setting and an easier recognition of any disruption, it is useful to arrange the measurement of the minimum pressure in the proximity of the pressure outlet point of the control pipe. Fig 2 shows a pressure reducing station with auxiliary energy, where instead of a pressure reducer, a pneumatic control valve (Pos.1) is introduced. In place of a outlet pressure pipe with a water seal pot, the pressure to be controlled is measured by a sensor and taken to an SPS control. Here, the actual measured value is compared with the preset value and the resulting control signal (e.g ma) is taken to the positioner of the control valve. In addition to the electrical energy for the SPS control and the positioner, the control valve requires a further source of auxiliary energy, in this case compressed air. In contrast with the pressure reducing station, the remaining valves are the same without auxiliary energy and are also needed to perform the same functions. Fig. 2: Pressure reducing station with auxiliary energy

5 5/ Temperature control Fig. 3 shows a temperature regulating station without auxiliary energy, with steam as heat transfer medium and a tube bank heat exchanger as the heat transfer device (Pos. 21). The temperature regulating valve TEMPTROL (Pos. 1) functioning as the central component of the installation is shown in Fig 4. It functions without auxiliary energy on the principle of liquid expansion. Temperatures on the sensor bring about a change in volume in the capillary tube system, which are converted into a lift change in the actuator. The set value can be accurately set on the display unit. The requirements for temperature regulators are given in [2]. Fig. 3: Temperature regulating station without auxiliary energy After having passed the globe valve FABA (Pos. 4), the strainer (Pos. 5) and the seperator (Pos. 3) the steam is taken to the temperature regulating valve. After passing through a further globe valve (Pos. 6) it reaches the heat exchanger. Here, the steam is completely condensed via heat transfer to the secondary circuit

6 6/16 Adjusting knob Indicator unit Set point indicator Valve Actuator Capillary tube Sensor Fig. 4: Temperature regulator TEMPTROL condensate collection system via the steam trap CONA-S (Pos.17). By reason of its construction, this trap adapts itself immediately to the quantities of condensate formed according to the opening of the temperature regulating valve. The drained condensate from the seperator is collected as in the case of the pressure reduction station, but due to its higher temperature, it is taken via a nozzle tube (Pos. 22) to the condensate collection system. For starting the installation, a vent (Pos. 23) is arranged between the temperature control valve and the input of the heat exchanger unit. The vacuum breaker (Pos. 24) next to the vent prevents an inadmissible vacuum, which may formed during the cooling of the installation. The temperature control station shown in Fig 5 differs from that shown in Fig 4 only through the use of a control valve with an electrical actuator and an integrated electronic temperature regulator (Pos. 1). This system accordingly functions with electrical auxiliary energy, a sensor (e.g. PT100) being used for temperature detection.

7 7/16 Fig. 5: Temperature regulating station with auxiliary energy 3. Technical process design 3.1. Checking of operating data An accurate design of a system is not possible without knowledge of exact and complete operating data. To ensure a rapid and correct design, the use of a checklist such as that shown in Fig 6 is useful. Mistakes can be avoided and the time needed for delivery shortened Selection of the system type The selection of the system type is determined in the first place by the principal requirements placed on the subsystem of the complete plant e.g. pressure control, temperature control and the like. The decision on "without auxiliary energy" or "with auxiliary energy" is governed by several factors. First of all, it is necessary to answer the question whether the required auxiliary energy is available in the location in question. Next, the requirements placed on control characteristic and accuracy must be checked. In the case of systems with auxiliary energy, the characteristic and accuracy can be

8 8/16 altered according to the regulators employed. Systems without auxiliary energy work with proportional regulators, where options of varying accuracy are limited. Behaviour, which may be required in the case of a failure of auxiliary energy is also a codeterminant of selection of installation type; for example, control valves with a safety function in the event of energy failure may be required. Fig. 6: Checklist for project planning

9 9/ Description and dimensioning, using the example of a pressure reducing station The basic procedure for the design of installation systems is described in detail below, using the example of a steam pressure reducing station (Fig 1) for individual valves/components. The dimensioning of the valves is given on the basis of the following installation data Medium : Saturated steam p 1 : 12 bar(g) p 2 : 8 bar (g) PS 1 : 14 bar(g) PS 2 : 10 bar(g) Capacity : 3000 kg/h It should be noted that the pressures p 1 and p 2 reproduce the normal operating conditions, whereas PS 1 is the protecting pressure of the feed system and PS 2 the protecting pressure of the system components behind the pressure reducer = set pressure of the safety valve of this pressure reducing station Pressure reducing valve PREDU The functioning of the pressure reducer is explained by means of the diagram (Fig 7). The minimum pressure reaches the diaphragm in the actuator and is converted into a Upstream pressure Downstream pressure Seat Water seal pot Disc Spring Actuator Diaphragm Control line Fig. 7: Pressure reducing valve PREDU

10 10/16 force, which is directed against the force of the spring. By means of setting it, it is possible to alter the pre-tension of the spring in such a way that at the desired minimum pressure the two forces are in balance. If the quantity of steam being extracted is then changed, the plug is moved until balance is again reached. To protect the diaphragm from excessive steam temperatures, the control pipe and the water seal pot are filled with water. The quick and accurate calculation of the pressure reducer PREDU is made possible through the computer programme ARI-VASI [3]. After the input of the before mentioned data and the selection of pipes according to the maximum speed of 25 m/s for saturated steam (D 1 : DN 80; D 2 : DN 100), a K v value of 22.7 is obtained. Taking into account a correction factor of 1.25, the programme selects a pressure reducer DN 50 with K vs 32. According to the catalogue [1], a choice of set value ranges of bar and 8-16 bar is available for this pressure reducer. Here, the range bar should preferably be selected, since the control accuracy will then be smaller Globe valves FABA / orifice plate The nominal sizes of the globe valves FABA (Pos. 4, 6) in front and behind the pressure reducer are made equal to the nominal diameters of the pipes described in The size of the bypass pipe is dimensioned as the pipe in front of the pressure reducer. In the event of the pressure reducer being taken out of service, the globe valve in the bypass pipe must allow the required capacity to pass through. Since, however, this valve is chosen to be of the same size as the bypass pipe, its output is usually greater than required; in the concrete case, the globe valve FABA DN 80 has a K vs value of 89.5 [1] and hence as against the required value of K vs = 22.7, an approximately 4 times output. The maximum flow-through quantity must accordingly by reduced by means of a orifice plate arranged at the output of the valve. The calculation gives a orifice plate diameter of 24.3 mm. To ensure an exact setting, this valve is to be equipped with a regulating plug. In order to prevent misuse, the hand wheel should be secured with a sealed cap Safety valve SAFE The safety valve SAFE serves for the protection of the downstream pressure installation part behind the pressure reducer, corresponding to the maximum possible pressure on the associated components and pipes. The arrangement must ensure that the downstream pressure pipe, the pressure reducer actuator and the bypass pipe are directly connected to the safety valve (see Fig 1, Pos. 2). Reference must be made here to the required blow-off pipe behind the safety valve, which for reasons of clarity of representation is not however shown in Fig 1. Like all steam pipes, this too must be drained and the drained condensate safely led away. The size of SAFE valve is determined as follows. First, the set pressure is laid down, using the general guide p %, but < PN actuator and/or < PN minimum pressure

11 11/16 system, in this case PS 2 = 10 bar(g). The maximum blow-off is obtained from the flowthrough capacity of the pressure reducer (see 3.4) calculated with ARI-VASI [4] (PS 1 +10% = 15,4 bar(g)/ps 2 = 10 bar(g) with Q = 5326 kg/h. The size determination of SAFE using the programme ARI-VASI gives figure 902 DN 50. The safety valve of this size is nevertheless only correctly dimensioned, if the bypass valve is not simultaneously open to the pressure reducer. Since, however, both pipes are able to be opened, the flow-through capacities of the pressure reducer and the bypass pipe must be added together. In this case, the blow-off output, which is to be removed, rises to 9191 kg/h and the required SAFE to DN 65. Since with the bypass pipe closed, the SAFE is overdimensioned, it is in this case recommended to introduce a second SAFE. The set pressure of the first SAFE should then be somewhat lower. The requirements placed on safety valves are defined in [4,5] Strainer/ seperator For the protection of the plug and the seat of the pressure reducer, the addition of a strainer (Pos. 5) is required. To prevent accumulations of condensate, the strainer should be mounted with the sieve lying on the side. The nominal width chosen should be the same as the diameter of the pipe. To remove the condensate drops carried by the flow, which may lead to erosion in the plug/seat area of the pressure reducer and its diversion, a seperator (Pos. 3) is placed in front of the pressure reducer. The associated drying of the steam has a certain simultaneous cleaning effect on any finely-divided dirt, which cannot be removed by the screen of the strainer Steam trap CONA The condensate, which collects in the seperator, must be removed without delay. This takes place via the steam trap CONA -S (Pos. 13). The size of this trap depends on the quantity of condensate in the area to be drained in front of the pressure reducing station. The determination of size will not be discussed here. The area behind the pressure reducer should also be drained and Fig 1 shows a bimetallic steam trap CONA -B (Pos. 17) used for this purpose Other components Further components are required for the monitoring of the functioning of the pressure reducing station (see Fig 1). The functioning of the steam trap can be controlled visually with the help of sight glasses (Pos. 12, 18). From time to time, it may become necessary to blow out the sludge, which may have collected in the condensate supports by the opening of the sludge valves (Pos. 14, 16), where a safe removal must be ensured. Using the gauges (Pos. 9, 10) in front and behind the pressure reducer, it is possible to check the control and possibly to correct the minimum pressure setting by means of moving the adjusting plate on the pressure reducer. Further information concerning the steam pressure reducing station and the valves for steam applications is given in [6,7].

12 12/16 4. Documentation To ensure perfect delivery, correct installation and commissioning, smooth service and many years of operation requiring only limited maintenance of an installation or of a system, a correct and complete documentation is needed. This includes first of all a general data sheet containing all the important information such as for example, versions and dimensions and the like as shown in Fig 8. Fig. 8: Data sheet for ARI pressure reducing station

13 13/16 Fig. 9: System specification sheet for ARI pressure reducing station

14 14/16 The current station is described in the installation specification sheet containing exact product data (see Fig 9). In addition, every installation has an operating and installation instruction, with all data concerning assembly and commissioning, including safetyrelevant instructions (Fig. 10). Fig. 10: Operating and installation instructions for ARI pressure reducing station

15 15/16 5. Certification A plant system, which is to be supplied and installed in Europe, is subject to various European guidelines. The most important is the "Pressure equipment directive" (PED) 97/23/EC [8], which specifies various conformity assessment procedures according to size of installation and the potential dangers. The assessment of an installation is governed by the highest category of an installation component (article 10 paragraph 2), with safety function valves such as safety valves not being taken into account. If the limits defined in article 3 paragraphs (1) and (2) (PS x l or PS x DN) are not exceeded, the installation is to comply with to article 3 paragraph (3) "Sound engineering practice" and does not receive any EC mark or conformity declaration. It is useful to document this by a manufacturer s certification. If these limits are exceeded, then various modules are to be chosen according to category. Starting with category I, a manufacturer s self-certification according to module A is provided, the installation receives an EC mark and a conformity declaration. In the case of higher categories the conformity assessment procedure and the certification are to be carried out alongside a nominated organisation. If, however, a part of the installation such as a pressure reducing station is not furnished by the supplier completely assembled, but in individual parts and only assembled at its destination, only the individual parts are to be assessed and possible certified according to the guideline. The certification of the subsystem is only given by the manufacturer of the complete installation. Depending on the type of the installation system, other European guidelines must also be observed; these will not be dealt with in detail here and include - Electromagnetic compatibility directive 89/336/EEC - Low voltage equipment directive 73/23/EEC - Machinery safety directive 98/37/EC

16 16/16 6. Summary In large systems the number of components to be obtained separately can be reduced considerably if parts of the system such as pressure reducing or temperature regulating stations are delivered in one unit. The planner then neither needs to deal with the details of component sizing and selection, as in the case of valves and pipes, for example, nor to verify that they comply with all rules and regulations, with the result that he can concentrate on his main task, the system. Once all requirements for the subsystem have been defined, the supplier is responsible for component sizing and selection, ensures correct certification, and compiles all the necessary documentation. The subsystem should preferably be delivered fully assembled, or in separate parts for on-site assembly. 7. Bibliography [1] ARI-Armaturen: Manufacturer s catalogue, 2005 [2] DIN 3440: Thermostats, temperature limiters and thermal cut-offs for heat generating systems [3] ARI Armaturen: Computer calculation programme ARI-VASI [4] TRD 421: Safety valves against excessive pressure safety valves for steam boilers [5] EN ISO : Safety devices for protection against excessive pressure Part 1: safety valves [6] Stork, E.: Steam pressure reducing station for process and plant engineering. Industriearmaturen 2/2000, Vulkan-Verlag, Essen [7] Stork, E.: Valves for steam facilities. Industriearmaturen International Edition 2004, Vulkan-Verlag, Essen [8] Pressure equipment directive (PED) 97/23/EC

Pressure reducing station. ARI-Pressure reducing station, self-acting or with electro-pneumatic control. ARI-PREsys -S. Pressure reducing station

Pressure reducing station. ARI-Pressure reducing station, self-acting or with electro-pneumatic control. ARI-PREsys -S. Pressure reducing station ARI-, self-acting or with electro-pneumatic control ARI-PREsys -S for steam ready for operation self-acting or with electro-pneumatic control Pipe material: P235GH 1.4571/1.4541 Valve materials: EN-JL1040

More information

Pressure reducing station. ARI-Pressure reducing station, self-acting or with electro-pneumatic control. ARI-PREsys -S. Pressure reducing station

Pressure reducing station. ARI-Pressure reducing station, self-acting or with electro-pneumatic control. ARI-PREsys -S. Pressure reducing station ARI-, self-acting or with electro-pneumatic control ARI-PREsys -S for steam ready for operation self-acting or with electro-pneumatic control Pipe material: P235GH 1.4571/1.4541 Valve materials: EN-JL1040

More information

PRESSURE REDUCING VALVE RP45 (EN)

PRESSURE REDUCING VALVE RP45 (EN) PRESSURE REDUCING VALVE RP45 (EN) DESCRIPTION The ADCA RP45 series pressure reducing valves are single seat bellows sealed controllers, operating without auxiliary energy, designed for use on steam, compressed

More information

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25 Self-operated Pressure Regulators Differential Pressure Regulators (opening) Type 42-20 Type 42-25 Type 42-20 Differential Pressure Regulator Type 42-25 Differential Pressure Regulator Mounting and Operating

More information

SAFE/REYCO. More than 35,000 variations in DIN EN and ASME. NEW! Now with zero leakage in combination with SHR premium soft seal* (now up to +220 C)

SAFE/REYCO. More than 35,000 variations in DIN EN and ASME. NEW! Now with zero leakage in combination with SHR premium soft seal* (now up to +220 C) NEW! Now with zero leakage in combination with SHR premium soft seal* (now up to +220 C) SAFE/REYCO More than 35,000 variations in DIN EN and ASME * Steam / Hot Water Resistance SAFE Full-lift safety valve

More information

PRESSURE REDUCING VALVE RP45 (ANSI)

PRESSURE REDUCING VALVE RP45 (ANSI) PRESSURE REDUCING VALVE RP45 (ANSI) DESCRIPTION The RP45 series pressure reducing valves are single seat bellows sealed controllers, operating without auxiliary energy, designed for use on steam, compressed

More information

Pressure Reducing Valve for Steam Type 2333 A

Pressure Reducing Valve for Steam Type 2333 A Pressure Reducing Valve for Steam Type 2333 A Fig. 1 Type 2333 A 1. Design and principle of operation The pressure reducing valve consists of a balanced control valve and a closing actuator equipped with

More information

Operational Behaviour of Safety Valves with Constant Superimposed Backpressure

Operational Behaviour of Safety Valves with Constant Superimposed Backpressure Operational Behaviour of Safety Valves with Constant Superimposed Backpressure Arne Gastberg Albert Richter ARI-Armaturen GmbH & Co. KG When selecting spring loaded safety valves, an accurate knowledge

More information

Mounting and Operating Instructions EB EN. Self-operated Pressure Regulators. Type 2335 Excess Pressure Valve with pilot valve

Mounting and Operating Instructions EB EN. Self-operated Pressure Regulators. Type 2335 Excess Pressure Valve with pilot valve Self-operated Pressure Regulators Type 2335 Excess Pressure Valve with pilot valve Type 2335 Excess Pressure Valve Mounting and Operating Instructions EB 2552-2 EN Edition January 2016 Definition of signal

More information

Operating and installation instructions

Operating and installation instructions Pressure reducing station ARI-PREsys (Type PRS) (Illustration example) Contents 1.0 General information on operating instructions... 2-2 2.0 Notes on possible dangers... 2-2 2.1 Significance of symbols...

More information

Ball Float Steam Trap UNA 45 MAX, UNA 46 MAX, UNA 46A MAX PN 40/Class 300 DN 40, 50, 65

Ball Float Steam Trap UNA 45 MAX, UNA 46 MAX, UNA 46A MAX PN 40/Class 300 DN 40, 50, 65 Data Sheet 819346-02 Issue Date: 05/17 Ball Float Steam Trap UNA 45 MAX, UNA 46 MAX, UNA 46A MAX PN 40/Class 300, 50, 65 UNA 45hl MAX, UNA 46hl MAX, UNA 46Ahl MAX UNA 45v MAX with cover for mounting electrode

More information

Differential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN

Differential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN Differential Pressure Regulator Type 45-6 Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN Edition March 2008 Contents Contents Page 1 Design and principle of operation...................

More information

Ball Float Steam Trap UNA 43 PN 16/CL 125/JIS 10K UNA 46 PN 40/CL 150/CL 300/JIS 10K/JIS 20K DN 80, 100, 150, 3", 4", 6"

Ball Float Steam Trap UNA 43 PN 16/CL 125/JIS 10K UNA 46 PN 40/CL 150/CL 300/JIS 10K/JIS 20K DN 80, 100, 150, 3, 4, 6 Data Sheet 819584-00 Issue Date: 01/17 Ball Float Steam Trap UNA 43 PN 16/C 125/JIS 10K UNA 46 PN 40/C 150/C 300/JIS 10K/JIS 20K DN 80, 100, 150, 3", 4", 6" UNA 43 hl, UNA 46 hl UNA 43 v, UNA 46 v with

More information

Pressure Reducing Valve for steam RP 45

Pressure Reducing Valve for steam RP 45 Pressure Reducing Valve for steam RP 45 DESCRIPTION The RP45 series pressure reducing valves are single seat bellows sealed controllers, operating without auxiliary energy,designed for use on steam, compressed

More information

Pressure Equipment Directive (PED) 97/23/EC Page 033 of 124

Pressure Equipment Directive (PED) 97/23/EC Page 033 of 124 Pressure Equipment Directive (PED) 97/23/EC Page 033 of 124 13.7 Pressure Equipment Directive (PED) 97/23/EC 1 The Pressure Equipment Directive (PED) 97/23/EC applies to the design, manufacturing and conformity

More information

GUIDELINES. Systems. Pressure. Guidelines Acceptance of equipment, establishment of safe operating limits and fitness for service

GUIDELINES. Systems. Pressure. Guidelines Acceptance of equipment, establishment of safe operating limits and fitness for service GUIDELINES Pressure Systems Guidelines Acceptance of equipment, establishment of safe operating limits and fitness for service Document Reference: PSG 16 Issue 04 Dated 13/09/16 The Safety Assessment Federation

More information

SV60 Safety valves. for use with steam, gas and liquids

SV60 Safety valves. for use with steam, gas and liquids SV60 Safety valves for use with steam, gas and liquids Spirax Sarco safety valves - protecting people, plant and profit The SV60 spring loaded full lift safety valve range from Spirax Sarco has been designed

More information

Pressure reducing valves Index

Pressure reducing valves Index Index General information page Introduction 506 General introduction 507 for a steam plant 509 Product information BSP thread page Brass 510 ; BSP female thread 511 ; BSP male thread 513 Stainless steel

More information

Mounting and operating instructions EB 2530 EN. Self-operated Pressure Regulator. Pressure Reducing Valve Type M 44-2

Mounting and operating instructions EB 2530 EN. Self-operated Pressure Regulator. Pressure Reducing Valve Type M 44-2 Self-operated Pressure Regulator Pressure Reducing Valve Type M 44-2 Type M 44-2, connection G 1 4, K VS = 0.15 Type M 44-2, connection G 1, K VS = 6 Fig. 1 Type M 44-2 Pressure Reducing Valve Mounting

More information

Self-operated Pressure Regulators for special applications

Self-operated Pressure Regulators for special applications Self-operated Pressure Regulators for special applications Type 2357-31 Pressure Build-up Regulator with safety function and integrated excess pressure valve Application Pressure regulators for cryogenic

More information

Mounting and Operating Instructions EB 3017 EN. Self-operated Regulators

Mounting and Operating Instructions EB 3017 EN. Self-operated Regulators Self-operated Regulars Flow and Differential Pressure Regular Type 42-37 Flow and Differential Pressure or Flow and Pressure Regular Type 42-39 Type 42-37 Type 42-39 Fig. 1 Flow and differential pressure

More information

Mounting and Operating Instructions EB 2558 EN. Self-operated Pressure Regulators. Type Pressure Build-up Regulator

Mounting and Operating Instructions EB 2558 EN. Self-operated Pressure Regulators. Type Pressure Build-up Regulator Self-operated Pressure Regulators Type 2357-31 Pressure Build-up Regulator with safety function and integrated excess pressure valve Type 2357-31 with non-return unit at port C Ports A and B with soldering

More information

CAST IRON SAFETY VALVE TYPE 6301

CAST IRON SAFETY VALVE TYPE 6301 CHARACTERISTICS The 6301 safety valve is dedicated to protect the equipment from potential overpressure. This is an automatic device that closes when the pressure conditions are back to normal. It is a

More information

Compiled by: B Beard. Approved by: SH Carstens. Description of requirements and procedures for compact provers to be used as verification standards.

Compiled by: B Beard. Approved by: SH Carstens. Description of requirements and procedures for compact provers to be used as verification standards. 1. Scope Description of requirements and procedures for compact provers to be used as verification standards. 2. Reference documents Trade Metrology Act SANS1698 3. Policy A. BASIC REQUIREMENTS Compact

More information

Type 4708 Supply Pressure Regulator

Type 4708 Supply Pressure Regulator Type 478 Pressure Regulator Application pressure regulator used to provide pneumatic measuring and control equipment with a constant air supply Set point ranges. to.6 bar ( to 4 psi) or. to 6 bar (8 to

More information

Norval Pressure regulator

Norval Pressure regulator Norval Pressure regulator NORVAL Classification and Field of Application The NORVAL is a downstream pressure regulator, self actuated, spring loaded for medium and low pressure applications. It is suitable

More information

Mounting and Operating Instructions EB 2172 EN. Series 43 Temperature Regulators. Type 43-5 and Type Type Type 43-6

Mounting and Operating Instructions EB 2172 EN. Series 43 Temperature Regulators. Type 43-5 and Type Type Type 43-6 Series 43 Temperature Regulators Type 43-5 and Type 43-7 Type 43-6 Type 43-6 Type 43-7 with flanged valve body, DN 32 to 50 Type 43-5 Type 43-7 with welding ends Mounting and Operating Instructions EB

More information

KTM 50 (DN ) Installation, maintenance and operating instructions

KTM 50 (DN ) Installation, maintenance and operating instructions 52 762-306 09.2014 KTM 50 (DN 100-200) Installation, maintenance and operating instructions General High-performing and compact, these pressure-independent control valves for variable flow heating and

More information

GUIDANCE IN-SERVICE INSPECTION PROCEDURES

GUIDANCE IN-SERVICE INSPECTION PROCEDURES GUIDANCE IN-SERVICE INSPECTION PROCEDURES Number: PEC 13 Prepared by: Pressure Equipment Committee (TC1) Status: Issue: 07 Date: 16 th January 2018 Reference: Guidance for safety valve examination. SITUATION:

More information

Series 42 Self-operated Regulators Differential Pressure Regulators with Type 2424/Type 2428 Actuator (closing) Type Type 42-28

Series 42 Self-operated Regulators Differential Pressure Regulators with Type 2424/Type 2428 Actuator (closing) Type Type 42-28 Series 42 Self-operated Regulators Differential Pressure Regulators with Type 2424/Type 2428 Actuator (closing) and balanced Type 2422 Valve Type 42-24 Type 42-28 Application Differential pressure regulators

More information

Pressure and/or Temperature Pilot Operated Steam Regulators Series 2000

Pressure and/or Temperature Pilot Operated Steam Regulators Series 2000 Hoffman Specialty Regulators Regulators Pressure and/or Temperature Operated Regulators Series 2000 The Hoffman Specialty Series 2000 consists of main valves, pilot valves, wells and hardware kits. They

More information

2-port and 3-port valves PN 16

2-port and 3-port valves PN 16 OEM 2-port valves VVP459.10-0.63 to VVP459.25-6.3 3-port valves VXP459.10-0.63 to VXP459.25-6.3 3-port valves with bypass VMP459.10-0.63 to VMP459.20-4 2-port valves VVP459.25-6.3 to VVP459.40-25 3-port

More information

Type 4708 Supply Pressure Regulator

Type 4708 Supply Pressure Regulator Type 478 Pressure Regulator Application pressure regulators used to provide pneumatic measuring and control equipment with a constant air supply Set point ranges. to. bar ( to 4 psi). to bar (8 to 9 psi)

More information

FLUID POWER FLUID POWER EQUIPMENT TUTORIAL ACCUMULATORS. This work covers part of outcome 2 of the Edexcel standard module:

FLUID POWER FLUID POWER EQUIPMENT TUTORIAL ACCUMULATORS. This work covers part of outcome 2 of the Edexcel standard module: FLUID POWER FLUID POWER EQUIPMENT TUTORIAL ACCUMULATORS This work covers part of outcome 2 of the Edexcel standard module: UNIT 21746P APPLIED PNEUMATICS AND HYDRAULICS The material needed for outcome

More information

Pressure Equipment Directive PED 2014/68/EU Commission's Working Group "Pressure"

Pressure Equipment Directive PED 2014/68/EU Commission's Working Group Pressure C. ASSEMBLIES Guideline C-03 Guideline related to: Article 4 paragraph 2 The effect of the derogation in Article 4 paragraph 2 from the introductory paragraph in the same article is not clear. In the circumstances,

More information

Installation, Operating and Maintenance Instructions. V914 Cast Iron Flanged Swing Check Valve V914

Installation, Operating and Maintenance Instructions. V914 Cast Iron Flanged Swing Check Valve V914 Installation, Operating and Maintenance Instructions V914 Cast Iron Flanged Swing Check Valve V914 THE PRESSURE EQUIPMENT DIRECTIVE 97/23/EC and CE MARKING The Pressure Equipment Regulations 1999 (SI 1999/2001)

More information

2-Port Seat Valves with Flange, PN 16

2-Port Seat Valves with Flange, PN 16 4 45 2-Port Seat Valves with Flange, PN 6 VVF45... dular cast iron EN-GJS-400-5 valve body DN 50...50 k vs 9...00 m /h Can be equipped with SKB...- or SKC...- electrohydraulic actuators Use For use in

More information

Type 4708 Supply Pressure Regulator

Type 4708 Supply Pressure Regulator Type 708 Pressure Regulator Application pressure regulator used to provide pneumatic measuring and control equipment with a constant air supply Set point range 0.5 to bar (8 to 90 psi) The pressure regulator

More information

NAF-Trimball Control Ball Valves

NAF-Trimball Control Ball Valves NAF-Trimball Control Ball Valves Size DN 50-500, Size 2-20 PN 10 40, ANSI Class 150 and 300 Fk 41.65(9)GB 11.04 Primary characteristics The NAF-Trimball represents an entirely new approach for addressing

More information

What is LPG? Released Energy in the narrowest area. Clean and sure in the practise

What is LPG? Released Energy in the narrowest area. Clean and sure in the practise since 1975 The company FAS (Flüssiggas-Anlagen GmbH, Salzgitter) was established in 1975 as commercial enterprise for LPG equipment (propane/butane). At the end of the seventies the safety idea gained

More information

Safety Valves Selecting Safety Valves

Safety Valves Selecting Safety Valves 1 History In 1679 Denis Papin developed a pressure cooker using pressurized steam. While demonstrating it the first time to the Royal Society this pressure cooker exploded. Only after Papin invented the

More information

Steam Trap BK BK 212-ASME. Original Installation Instructions English

Steam Trap BK BK 212-ASME. Original Installation Instructions English Steam Trap BK 212.. BK 212-ASME EN English Original Installation Instructions 810609-02 1 Contents Page Important Notes Usage for the intended purpose... 3 Safety note... 3 Danger... 3 Attention... 3 Application

More information

Series 44 Self-operated Pressure Regulators. Type 44-0 B Pressure Reducing Valve. ANSI version

Series 44 Self-operated Pressure Regulators. Type 44-0 B Pressure Reducing Valve. ANSI version Series 44 Self-operated Pressure Regulators Type 44-0 B Pressure Reducing Valve ANSI version Application Set points from 3 to 290 psi (0.2 to 20 bar) with valves ½ NPT to 1 NPT as well as NPS ½ and 1 Pressure

More information

Versions. Benefits. Balancing DN15-32 DN40 DN50 DN15, DN20, DN25, DN32, DN40, DN50. Dimensions

Versions. Benefits. Balancing DN15-32 DN40 DN50 DN15, DN20, DN25, DN32, DN40, DN50. Dimensions Ballorex Delta Description The Ballorex Delta is a differential pressure control valve used in hydronic heating or cooling systems. By ensuring a constant differential pressure across motorized or static

More information

2-Port Seat Valves with Flange, PN 16

2-Port Seat Valves with Flange, PN 16 4 40 2-Port Seat Valves with Flange, PN 6 VVF4... Grey cast iron EN-GJL-250 valve body DN 50...50 k vs 9...00 m /h Can be equipped with SQX- electromotoric or SKD...-, SKB...- or SKC...- electrohydraulic

More information

POP Safety Valve. POP Safety Valve INTRODUCTION DEFINITIONS

POP Safety Valve. POP Safety Valve INTRODUCTION DEFINITIONS POP Safety Valve POP Safety Valve INTRODUCTION The effects of exceeding safe pressure levels in an unprotected pressure vessel or system, can have catastrophic effects on both plant and personnel. Safety

More information

Pilot Operated Pressure Reducing Valve

Pilot Operated Pressure Reducing Valve OPTIONS: USE: Pilot Operated Pressure Reducing Valve Steam & Compressed Air PRV 37 (DN15-DN50) DESCRIPTION The ADCA PRV37 pilot operated pressure reducing valves are designed for use on steam, compressed

More information

Unit 24: Applications of Pneumatics and Hydraulics

Unit 24: Applications of Pneumatics and Hydraulics Unit 24: Applications of Pneumatics and Hydraulics Unit code: J/601/1496 QCF level: 4 Credit value: 15 OUTCOME 2 TUTORIAL 9 ACCUMULATORS The material needed for outcome 2 is very extensive so there are

More information

Electropneumatic Positioner Type 4763 Pneumatic Positioner Type 4765

Electropneumatic Positioner Type 4763 Pneumatic Positioner Type 4765 Electropneumatic Positioner Type 4763 Pneumatic Positioner Type 4765 Application Single-acting positioner for attachment to pneumatic control valves. Supplied with either an electric input signal from

More information

Pressure relief valve DHV 716 set range: 0,5-10,0 bar

Pressure relief valve DHV 716 set range: 0,5-10,0 bar Pressure relief valve DHV 7 set range: 0,5-0,0 bar Advantage pressure setting possible at any time, also during operation optimum monitoring valves high reproducibility of the set pressure high level of

More information

Pressure Systems Safety Regulation

Pressure Systems Safety Regulation Pressure Systems Safety Regulation Introduction This document informs Faculty of the key requirements of the UK and Chinese Pressure Systems Safety regulations. The aim of these regulations is to prevent

More information

T 2523 EN Type 2406 Excess Pressure Valve Self-operated Pressure Regulators ANSI version

T 2523 EN Type 2406 Excess Pressure Valve Self-operated Pressure Regulators ANSI version T 2523 EN Type 2406 Excess Pressure Valve Self-operated Pressure Regulators ANSI version Application Excess pressure valve for set points from 0.075 to 150 psi (5 mbar to 10 bar) Valve size NPS ½ to 2

More information

Bermad Pressure Reducing. Model: 42T

Bermad Pressure Reducing. Model: 42T Bermad Pressure Reducing Pilot Operated Pressure Control Valve Model: 42T Installation Operation Maintenance Manual (IOM) REV. 27.7.17 Page 1 of 12 Safety First BERMAD believes that the safety of personnel

More information

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS Annex 3, page 2 ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS The text of existing chapter 15 is replaced by the following: "1 Application This

More information

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Type Type Differential Pressure Regulators (opening)

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Type Type Differential Pressure Regulators (opening) Self-operated Pressure Regulators Type 42-20 Type 42-25 Differential Pressure Regulators (opening) Translation of original instructions Type 42-20 Differential Pressure Regulator Type 42-25 Differential

More information

Safety Relief Valve HON 832

Safety Relief Valve HON 832 Safety Relief Valve HON 832 product information serving the gas industry worldwide Application, characteristics, technical data Application 2 As leak gas SRV with internal vent connection (function class

More information

CLASS TLP Pressure Reducing Valve

CLASS TLP Pressure Reducing Valve CLASS TLP Pressure Reducing Valve CLASS TLP Direct Acting Pressure Reducing Valve The Class TLP balanced direct acting pressure regulator is designed for use on installations that have varying inlet pressures

More information

Installation, Operating and Maintenance Manual Overflow Regulator Type 94/ 94 E

Installation, Operating and Maintenance Manual Overflow Regulator Type 94/ 94 E Installation, Operating and Maintenance Manual Overflow Regulator Type 94/ 94 E Table of content 1. General information on installation, operating and maintenance instructions 1.1 Hazard notices 1.2 Qualified

More information

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars. Simply a question of better measurement SCHMIDT Flow Sensor SS 20.261 The cost-effective alternative in pressurised systems up to 10 bars. Compressed air technology Industrial processes A cost analysis

More information

Three-port valves. Special versions with special stem sealing gland for: High temperature hot water C Thermo oils

Three-port valves. Special versions with special stem sealing gland for: High temperature hot water C Thermo oils 4 440 Three-port valves with flange, PN6 VXF4... Three-port valves with flange, PN6 Can be used as mixing or diverting valves Grey cast iron GG-25 DN5...50 mm k vs.9...300 m 3 /h Stroke 20 or 40 mm Can

More information

HANDBOOK. Squeeze Off Unit SOU 250. Please refer any queries to:

HANDBOOK. Squeeze Off Unit SOU 250. Please refer any queries to: HANDBOOK Squeeze Off Unit SOU 250 Please refer any queries to: Hy Ram Engineering Co Ltd Pelham Street Mansfield Nottinghamshire NG18 2EY Telephone No: (01623) 422982 Please note all queries should state

More information

Tubes Components Valves Units Engineering SO EVERYTHING KEEPS FLOWING. Safety valves Bunging valves Vacuum valves Tank dome fittings

Tubes Components Valves Units Engineering SO EVERYTHING KEEPS FLOWING. Safety valves Bunging valves Vacuum valves Tank dome fittings SO EVERYTHING KEEPS FLOWING Safety valves Bunging valves Vacuum valves Tank dome fittings Reliable reaction at the right moment Safety components are part of our everyday life. Like anti-skid systems in

More information

TD45 Thermodynamic Steam Trap Installation and Maintenance Instructions

TD45 Thermodynamic Steam Trap Installation and Maintenance Instructions 0685255/1 IM-P068-47 ST Issue 1 TD45 Thermodynamic Steam Trap Installation and Maintenance Instructions 1 General safety information 2 General product information 3 Installation 4 Commissioning 5 Operation

More information

OIL SUPPLY SYSTEMS ABOVE 45kW OUTPUT 4.1 Oil Supply

OIL SUPPLY SYSTEMS ABOVE 45kW OUTPUT 4.1 Oil Supply OIL SUPPLY SYSTEMS ABOVE 45kW OUTPUT 4.1 Oil Supply 4.1.1 General The primary function of a system for handling fuel oil is to transfer oil from the storage tank to the oil burner at specified conditions

More information

2/2-Way Solenoid Control Valve

2/2-Way Solenoid Control Valve 2/2-Way Solenoid Control Valve Excellent range (1:200) Very good response Compact valve design Orifice sizes 0.05... 2.0 mm Port connection 1/8 or sub-base Type 2871 can be combined with Type 8605 Digital

More information

Self-operated Pressure Regulators Type 2405 Pressure Reducing Valve

Self-operated Pressure Regulators Type 2405 Pressure Reducing Valve Self-operated Pressure Regulators Type 2405 Pressure Reducing Valve Application Pressure reducing valve for set points from 5 mbar to 10 bar Nominal size DN 15 to 50 Nominal pressure PN 16 to 40 Suitable

More information

Two-port seat valves

Two-port seat valves 4 345 Two-port seat valves with flange, PN16 VVF45... Two-port seat valves with flange, PN16 Spheroidal cast iron GGG-40 DN50...150 mm k vs 19...300 m 3 /h Stroke 20 or 40 mm Can be equipped with actuators

More information

ASX 176 Axial Pressure regulator

ASX 176 Axial Pressure regulator ASX 176 Axial Pressure regulator ASX 176 Classification and Area of Application ASX 176 is a downstream pressure regulator, pilot controlled, for medium and high pressure applications. It is particularly

More information

Operating Manual FSV, FSÖV, SSVF

Operating Manual FSV, FSÖV, SSVF Contents 1. General Remarks... 1 1.1. Marking... 2 1.2. Tightness of the Quick-Closing Valve... 2 1.3. Medium... 2 1.4. Ambient and Medium Temperature... 3 1.5. Vibrations... 3 1.6. Pipe Tensions... 3

More information

Neotecha SAPRO - Aseptic sampling valve SV Installation, operation and maintenance instructions

Neotecha SAPRO - Aseptic sampling valve SV Installation, operation and maintenance instructions Before installation these instructions must be fully read and understood 2 Safety Please read these instructions carefully. 2.1 General danger potential Not paying attention to this instruction Incautious

More information

2-port and 3-port seat valves, PN16

2-port and 3-port seat valves, PN16 s 4 47 VVI47 VXI47 CVTIX 2-port and 3-port seat valves, PN6 with internally threaded connections VVI47.. VXI47.. ronze valve body CC49K (Rg5) DN 5...5 k vs 2.5...4 m 3 /h Internally threaded connections

More information

6301 TYPE CAST IRON SAFETY VALVES

6301 TYPE CAST IRON SAFETY VALVES Pressure (bar) 6301 TYPE CAST IRON SAFETY VALVES FEATURES The 6301 type safety valve is a device designed to protect installations against possible overpressure. It operates automatically and closes when

More information

Pilot HON 625. Entwurf. Product information. serving the gas industry worldwide

Pilot HON 625. Entwurf. Product information. serving the gas industry worldwide Pilot HON 62 Entwurf Product information serving the gas industry worldwide Pilot HON 62 Application, characteristics Application Pilot for the gas pressure regulator HON 02 Pilot for outlet pressure control

More information

Fig. Art. 515 121 Pressure reducing valve DVGW approved pressure: max. 25 bar (362,50 psi) Outlet pressure adjustable between 1,5 bar (21,8 psi) and 6 bar (87 psi) Factory pre-set to 4 bar ( psi) Temperature

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS 0/05 OPERATING INSTRUCTIONS for gas pressure regulators PN0 with integrated slam shut valve (SSV) and integrated limited capacity safety relief valve (RV) MR 25 F0, MR 25 SF0 p e 20 kpa - 0 MPa (0,2-0

More information

VGG... VGF... VGH... Gas Valves. Siemens Building Technologies HVAC Products VGG... VGF... VGH...

VGG... VGF... VGH... Gas Valves. Siemens Building Technologies HVAC Products VGG... VGF... VGH... 7 636 VGG... VGF... VGH... Gas Valves VGG... VGF... VGH... Single valves of class A for installation in gas trains Safety shutoff valves conforming to EN 161 in connection with SKP... actuators Suitable

More information

INSTALLATION OPERATION MAINTENANCE

INSTALLATION OPERATION MAINTENANCE Bermad Electrically Controlled On-Off Deluge Valve Model: 400E-3D INSTALLATION OPERATION MAINTENANCE Application Engineering BERMAD 1. Safety First BERMAD believes that the safety of personnel working

More information

Flamco Airfix D-E. Installation and operating instructions. 1999, Flamco eps

Flamco Airfix D-E. Installation and operating instructions. 1999, Flamco eps Airfix D-E 6442.eps GB Installation and operating instructions 1999, Exclusion of liability All operation and maintenance related technical information, data and instructions contained in these installation

More information

SCA Series Inverted Bucket Steam Traps

SCA Series Inverted Bucket Steam Traps 0770050/5 IM-P077-06 ST Issue 5 SCA Series Inverted Bucket Steam Traps Installation and Maintenance Instructions 1. General safety information 2. General product information 3. Installation 4. Commissioning

More information

Paul Ladage 26 September 2017 MOVING THINGS AROUND - LATEST TRENDS IN HONEYWELL FLAGSHIP REGULATORS

Paul Ladage 26 September 2017 MOVING THINGS AROUND - LATEST TRENDS IN HONEYWELL FLAGSHIP REGULATORS Paul Ladage 26 September 2017 MOVING THINGS AROUND - LATEST TRENDS IN HONEYWELL FLAGSHIP REGULATORS Agenda 1 What do we sell? Flagship Products HON 5020 HON R100 NG HON 512, class 150 Q&A Where Do Honeywell

More information

Self-operated Regulators Accessories Differential Pressure and Flow Regulators

Self-operated Regulators Accessories Differential Pressure and Flow Regulators Self-operated Regulators Accessories Differential Pressure and Flow Regulators Compression-type fittings Needle valves Compensation chambers Orifice plates Welding neck flanges Control lines Application

More information

Self-operated Pressure Regulators Type 2405 Pressure Reducing Valve

Self-operated Pressure Regulators Type 2405 Pressure Reducing Valve Self-operated Pressure Regulators Type 2405 Pressure Reducing Valve ANSI version Application Pressure reducing valve for set points from 0.075 to 150 psi (5 mbar to 10 bar) Valve size NPS ½ to 2 1) (DN

More information

Self-operated Pressure Regulators Type Universal Pressure Reducing Valve

Self-operated Pressure Regulators Type Universal Pressure Reducing Valve Self-operated Pressure Regulators Type 41-23 Universal Pressure Reducing Valve JIS version Application Pressure regulators for set points from 5 to 2800 kpa/0.05 to 28 bar Valve sizes ½B/15A to 4B/100A

More information

VGG... VGF... VGH... Gas Valves. Building Technologies HVAC Products VGG... VGF... VGH...

VGG... VGF... VGH... Gas Valves. Building Technologies HVAC Products VGG... VGF... VGH... 7 66 VGG... VGF... VGH... Gas Valves VGG... VGF... VGH... Single valves of class A for installation in gas trains Safety shutoff valves conforming to EN161 in connection with actuators Suitable for use

More information

Model: 43T. Bermad Pressure Relief Valve

Model: 43T. Bermad Pressure Relief Valve Model: 43T Bermad Pressure Relief Valve Installation Operation Maintenance Manual () Rev.C1_01.08.17 Page 1 of 10 Safety First BERMAD believes that the safety of personnel working with and around our equipment

More information

TEST SPECIFICATION NYT-909-C

TEST SPECIFICATION NYT-909-C 748 Starbuck Ave, Watertown, NY 13601 Phone: +1-315-786-5200 Engineering Fax: +1-315-786-5673 TEST SPECIFICATION NYT-909-C CODE OF TESTS FOR TESTING "AB" TEST RACK P/N 702546 & 702612 ISSUE NO. 5 1.0 THE

More information

776 Cryogenic Safety Valve

776 Cryogenic Safety Valve 776 Cryogenic Safety Valve INTRODUCTION 776 Cryogenic Safety Valve The effects of exceeding safe pressure levels in an unprotected pressure vessel or system, can have catastrophic effects on both plant

More information

Spirax Compact FREME Flash Recovery Energy Management Equipment

Spirax Compact FREME Flash Recovery Energy Management Equipment IM-UK-cFREME UK Issue 1 Spirax Compact FREME Flash Recovery Energy Management Equipment Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4.

More information

Description. Functions. Technical data. Applications. Tests. On-Off 2 levels float control valve, closing at high level and opening at low level.

Description. Functions. Technical data. Applications. Tests. On-Off 2 levels float control valve, closing at high level and opening at low level. DN 0 to 1000 - Serie K3 0 On-Off levels float control valve, closing at high level and opening at low level. Functions Prevents overflowing and closes at a constant and adjustable high level. Remains closed

More information

MAKING MODERN LIVING POSSIBLE. Pilot operated internal safety valves type POV REFRIGERATION AND AIR CONDITIONING DIVISION.

MAKING MODERN LIVING POSSIBLE. Pilot operated internal safety valves type POV REFRIGERATION AND AIR CONDITIONING DIVISION. MAKING MODERN LIVING POSSIBLE Pilot operated internal safety valves type POV REFRIGERATION AND AIR CONDITIONING DIVISION Technical leaflet Contents Page Introduction...3 Features...3 Design...4 Technical

More information

VG3000. Globe Valves Series for Terminal Units. Product Bulletin. 2-way PDTC (NO) with 6 bar close off pressure. Extend range of K VS

VG3000. Globe Valves Series for Terminal Units. Product Bulletin. 2-way PDTC (NO) with 6 bar close off pressure. Extend range of K VS VG3000 Globe Valves Series for Terminal Units Product ulletin The VG3000 brass valve series is primarily designed to regulate the flow of water in response to the demand of a controller in zone and terminal

More information

3-port seat valves with externally threaded connection, PN 16

3-port seat valves with externally threaded connection, PN 16 4 463 Acvatix 3-port seat valves with externally threaded connection, PN 16 VXG41.. ronze CuSn5Zn5Pb2 valve body DN 15 50 k vs 1.6 40 m 3 /h Flat sealing connections with external thread G to ISO 228-1

More information

C 10 Pressure Reducing Valve

C 10 Pressure Reducing Valve C 10 Pressure Reducing Valve C 10 Direct Acting Pressure Reducing Valve The C10 balanced pressure reducing valve range is designed for use on water/air (gas) applications and for installations which have

More information

Manual Actuated Boiler Blowdown Valves

Manual Actuated Boiler Blowdown Valves Manual Actuated Boiler Blowdown Valves Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4. Operation 5. Maintenance 6. Spare parts p.1 1. Safety

More information

VG3000. Globe Valves Series for Terminal Units. Product Bulletin. 2-way PDTC (NO) with 6 bar close off pressure. Extend range of K VS

VG3000. Globe Valves Series for Terminal Units. Product Bulletin. 2-way PDTC (NO) with 6 bar close off pressure. Extend range of K VS VG3000 Globe Valves Series for Terminal Units Product ulletin The VG3000 brass valve series is primarily designed to regulate the flow of water in response to the demand of a controller in zone and terminal

More information

Valves. Diaphragm shut-off valves, kidney-type

Valves. Diaphragm shut-off valves, kidney-type Valves Diaphragm shut-off valves, kidney-type Application When leakage of even the smallest quantities must be avoided with certainty For maximum requirements to operating safety For maximum requirements

More information

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS Electropneumatic Positioner and Pneumatic Positioner Type 3760 Application Single-acting positioners for direct attachment to pneumatic control valves. Supplied with an electric input signal of 4 to 20

More information

HANDBOOK. Squeeze Off Unit SOU 400. Please refer any queries to:

HANDBOOK. Squeeze Off Unit SOU 400. Please refer any queries to: HANDBOOK Squeeze Off Unit SOU 400 Please refer any queries to: Hy Ram Engineering Co Ltd Pelham Street Mansfield Nottinghamshire NG18 2EY Telephone No: (01623) 422982 Please note all queries should state

More information

VGG... VGF... VGH... Gas Valves. Building Technologies HVAC Products VGG... VGF... VGH...

VGG... VGF... VGH... Gas Valves. Building Technologies HVAC Products VGG... VGF... VGH... 7 66 VGG... VGF... VGH... Gas Valves VGG... VGF... VGH... Single valves of class A for installation in gas trains Safety shutoff valves conforming to EN 161 in connection with SKP... actuators Suitable

More information

Pressure relief valve DHV 712 DN 65-80: 0,5-10 bar, DN : 0,3-4 bar, DN 100: 0,5-6 bar

Pressure relief valve DHV 712 DN 65-80: 0,5-10 bar, DN : 0,3-4 bar, DN 100: 0,5-6 bar Pressure relief valve DHV 7 DN 5-80: 0,5-0 bar, DN 5-00: 0, - bar, DN 00: 0,5 - bar Advantage for high pressure stability reliable reduction of pressure peaks and pulsations pressure setting possible at

More information