10/2002 INERTING PROTOCOL

Size: px
Start display at page:

Download "10/2002 INERTING PROTOCOL"

Transcription

1 10/2002 INERTING PROTOCOL R

2

3 INERTING PROTOCOL Inerting a volume: Inerting a volume consists in replacing an unwanted gas (air or toxic substance) by an inert gas (i.e. nitrogen). This is done to avoid the degradation of the handled product, the oxygen content must generally be < 0,5%. Three methods can be applied to the enclosure: - Positive pressure cycle - Negative pressure cycle - Gas flushing. The positive pressure or negative pressure cycles are the most efficient. The principle is to place a volume successively under pressure with an inert gas and then decompress it to the air atmospheric pressure ( positive pressure cycle), or to create a vacuum and then restore pressure with an inert gas (negative pressure cycle). The most inaccessible gas pockets of the volume are in this way treated with the same efficiency as the main volume. However, these two methods can only be applied efficiently to enclosures that can resist to vacuum or pressure. For enclosures that can only resist to low pressure or negative pressure, flushing is the only method that can be used. Its principle is to introduce an inert gas into one end so as to repel the unwanted gas towards the other end. As far as the Captair pyramid is concerned, we recommend a combination of the three methods in order to obtain the most efficient result.

4 ZIP After having set up your pyramid, open the resealable zipper and introduce the samples or the equipment needed for your handling under inert atmosphere. You can then close the enclosure, but you must leave a small opening at the top of the zipper track with the help of the black cursor. Unhook the Captair pyramid from the L-shaped post.. Negative pressure cycle Slowly let the air out of the Captair pyramid so as to blow away the maximum amount of air through the small opening left at the top of the zipper track. When finished, close the enclosure completely with the zipper and its black Cursor.

5 Negative pressure cycle Connect a vacuum pump to the valve with a rigid plastic tubing using one of the two nozzles fixed to the Captair pyramid. Negative pressure cycle Switch the vacuum pump on so as to obtain the maximum negative pressure. Negative pressure cycle When finished, disconnect the nozzle and stop the vacuum pump.

6 Positive pressure cycle The inert gas cartridge must be equipped with a dual stage regulator possibly connected to a flow and pressure regulation device or equipped with a flow-regulating valve. The second level manometer must be adjusted to A maximum pressure of 1 bar. Connect the Captair pyramid valve with a plastic tubing and the other nozzle linked to the activated inert gas cartridge. Positive pressure cycle Slowly inflate the Captair pyramid to 100 mbar pressure until it has reached its normal shape with its sides slightly rounded. Positive pressure cycle When the Captair pyramid has returned to its normal shape, hook it up to the L-shaped Post.

7 Flushing After inflating, keep a flushing pressure of 10 mbar during your handling. Flushing The flushing pressure will keep an internal pressure of 5 mbar while compensating for possible leakages..

8

9

10 World Leader EUROPE FRANCE : GERMANY : SPAIN : ITALY : UK : NORTH AMERICA USA : ASIA MALAYSIA : erlab D. F. S. S.A. Parc d affaires des Portes BP Val de Reuil Cedex erlab D. F. S. S.A. Vertretungsbüro DeutschlandPostfach KÖLN erlab D. F. S. S.A. Oficina Comercial en España Ruiz Alarcón, Madrid erlab D. F. S. S.A. Officio di rappresentanza in Italia Via Cusani, Milano erlab D. F. S. S.A. UK and IRELAND representationoffice St Thomas s House / St Thomas s square Salisbury - SPI IBA Wiltshire erlab inc. One Elm Square 1980 Turnpike Street North Andover, MA erlab Asia sdn bhd 25 jalan Firma 2/1Kawasan Perindustrian - Terbrau Johor Bahru State Malaysia Tél : +33 (0) Fax : +33 (0) Ventes@erlab.net Tel : 0211 / Fax : 0211 / Verkauf@erlab.net Tel : Fax : Ventas@erlab.net Tel : Fax : Vendite@erlab.net Phone : Fax : SalesUK@erlab.net Phone : (800) Fax : 1 (978) CaptairSales@erlab.net Tél : +60 (0) Fax : +60 (0) erlab@tm.net.my

About us. We supply Industrial gases, calibration gases, Medical gas Fireman protection and equipment

About us. We supply Industrial gases, calibration gases, Medical gas Fireman protection and equipment About us AIRGAS TECHNOLOGY Sdn Bhd, We specialize in supply of all range of industrial gases, gas cylinder, valve, regulator, hoses, personal protection equipment s for fireman and industrial, firefighting

More information

MATERIAL SAFETY DATA SHEET. Product: PTFE/FEP

MATERIAL SAFETY DATA SHEET. Product: PTFE/FEP HYDRO SEALING TECHNOLOGY SDN BHD ( 426172-P ) ( Sales Tax ID No : J31-1808-21018370 ) No.5, Jalan Tiong Emas 4, Kawasan Perindustrian Tiong Nam, 81100, Johor Bahru, Johor, Malaysia. Tel : 07-362 0022 Fax

More information

RCV-125 REMOTE CONTROL SYSTEM IMPORTANT WARNING FOR SAFER BLAST CLEANING

RCV-125 REMOTE CONTROL SYSTEM IMPORTANT WARNING FOR SAFER BLAST CLEANING OWNER S MANUAL RCV-125 REMOTE CONTROL SYSTEM IMPORTANT WARNING FOR SAFER BLAST CLEANING 1. Use protective equipment: Abrasive-resistant clothing, safety shoes, leather gloves, ear protection, CE-approved

More information

Operating Guidelines for PermSelect Modules Liquid Contacting

Operating Guidelines for PermSelect Modules Liquid Contacting Operating Guidelines for PermSelect Modules Liquid Contacting PermSelect PDMSXA-2500 (0.25m 2 ) PermSelect PDMSXA-7500 (0.75m 2 ) PermSelect PDMSXA-1.0 (1m 2 ) PermSelect PDMSXA-2.1 (2.1m 2 ) PermSelect

More information

Tourniquet Systems Pressure Infusion

Tourniquet Systems Pressure Infusion Tourniquet Systems Pressure Infusion VBM Medizintechnik GmbH VBM 1 VBM 2 Summary Tourniquets and Accessories Digital Tourniquets... Compressed Air Tourniquets... Electronic Tourniquets... Application Tourniquets...

More information

Inert Air (N2) Systems Manual

Inert Air (N2) Systems Manual INSTRUCTION MANUAL Inert Air (N2) Systems Manual N2-MANUAL 2.10 READ AND UNDERSTAND THIS MANUAL PRIOR TO OPERATING OR SERVICING THIS PRODUCT. GENERAL INFORMATION Positive pressure nitrogen gas pressurizing

More information

Pressure gauges EN All stainless steel construction PBX100, PBX150 (1.18) Functional and constructive characteristics

Pressure gauges EN All stainless steel construction PBX100, PBX150 (1.18) Functional and constructive characteristics Pressure gauges FT PBX 100-150-E-9.02 All stainless steel construction PBX100, PBX150 (1.18) EN 837-1 These instruments are designed for use in food, beverage, pharmaceutical, cryogenics, chemical and

More information

COMPRESSOR REPLACEMENT PROCEDURE (R-134A)

COMPRESSOR REPLACEMENT PROCEDURE (R-134A) 372 ROUTE 4 BARRINGTON, NH 03825 USA TEL (603) 868-5720 FAX (603) 868-1040 1-800-435-6708 COMPRESSOR REPLACEMENT PROCEDURE (R-134A) [ ] If possible operate the compressor with proper charge for 5 minutes

More information

2013 YKK Asia Group Kids Football Clinic Supporting healthy Growth of Children through Sports A YKK ASIA GROUP CSR Project

2013 YKK Asia Group Kids Football Clinic Supporting healthy Growth of Children through Sports A YKK ASIA GROUP CSR Project 2013 YKK Asia Group Kids Football Clinic Supporting healthy Growth of Children through Sports A YKK ASIA GROUP CSR Project Press Release FOR IMMEDIATE RELEASE YKK Holding Asia Pte Ltd (YHA) partners with

More information

ZUERCHER TANK REGULATORS PRINCIPLES OF TANK VENTILATION

ZUERCHER TANK REGULATORS PRINCIPLES OF TANK VENTILATION Why Inertisation (blanketing) of Tanks? General Tank inertisation or blanketing is required in many applications where products or liquids stored in the tank are processed and/or filled into and emptied

More information

OPTIMA 7 - BIOGAS Calibrating the gas sensors SENSOR ADJUSTMENT. Diamond Scientific 625 Peachtree St., Cocoa, Florida /Tel:

OPTIMA 7 - BIOGAS Calibrating the gas sensors SENSOR ADJUSTMENT. Diamond Scientific 625 Peachtree St., Cocoa, Florida /Tel: SENSOR ADJUSTMENT The calibration of your OPTIMA 7 should be performed by experienced service personal only! MRU will not be responsible for any misuse or wrong interpretation of this calibration instruction.

More information

Advanced Test Equipment Rentals ATEC (2832)

Advanced Test Equipment Rentals ATEC (2832) Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) VS Series Leak Detectors for Vacuum Furnaces Rate of rise and vacuum decay tests will not locate leaks, they will only

More information

Pressure gauges EN Safety pressure gauges solid-front PBXSF100, PBXSF150 (1.20) Functional and constructive characteristics

Pressure gauges EN Safety pressure gauges solid-front PBXSF100, PBXSF150 (1.20) Functional and constructive characteristics Pressure gauges FT PBXSF 100-150-E-9.02 Safety pressure gauges solid-front PBXSF100, PBXSF150 (1.20) EN 837-1 These Solid-Front instruments are built in accordance with safety specifications of EN 837.1

More information

Accessories. Differential pressure gauges for air and gas MAG-A & MAG-G (E5275 rev /04/2010)

Accessories. Differential pressure gauges for air and gas MAG-A & MAG-G (E5275 rev /04/2010) Accessories Differential pressure gauges for air and gas MAG-A & MAG-G (E5275 rev. 02-12/04/2010) GENERAL WARNINGS: DISPOSAL: ¾ All installation, maintenance, ignition and setting must be performed by

More information

AMCA INTERNATIONAL CORPORATE CAPABILITIES. The International Authority on Air System Components Since 1917

AMCA INTERNATIONAL CORPORATE CAPABILITIES. The International Authority on Air System Components Since 1917 AMCA INTERNATIONAL CORPORATE CAPABILITIES The International Authority on Air System Components Since 1917 ABOUT AMCA The Air Movement and Control Association (AMCA) International, a not-for-profit association

More information

PRESSURE REDUCTION FLOWMETERING, QUICK COUPLING PROBES AND ACCESSORIES

PRESSURE REDUCTION FLOWMETERING, QUICK COUPLING PROBES AND ACCESSORIES PRESSURE REDUCTION FLOWMETERING, QUICK COUPLING PROBES AND ACCESSORIES 1 3 1 - ALPINOX: oxygen Regulator - Medical oxygen regulator with flowmeter. - Medical oxygen regulator with flowmeter and Quick

More information

For Air Pressure. AP-30 Series. Digital Display & Digital Control. EASY-TO-SEE 2-color display. Two-color digital display pressure sensor

For Air Pressure. AP-30 Series. Digital Display & Digital Control. EASY-TO-SEE 2-color display. Two-color digital display pressure sensor Cat No AP3-KA-C Two-color digital display pressure sensor AP-3 Series Digital Display & Digital Control For Air Pressure EASY-TO-SEE 2-color display Green and red two-color LED display clearly shows abnormal

More information

Product Catalogue. P-SERIES Pressure Gauges

Product Catalogue. P-SERIES Pressure Gauges Product Catalogue P-SERIES Pressure Gauges 2 3 CONTENT INTRODUCTION PRESSURE GAUGES...4 P-SERIES (Gauges for Pressure and Vacuum)...6-25 P-SERIES Model P1 (Stainless Steel Bourdon-Tube Pressure Gauge)...6

More information

Premium Solutions for Gas and Biogas Handling

Premium Solutions for Gas and Biogas Handling Premium Solutions for Gas and Biogas Handling Blower Solutions for Gas & Biogas Type of gas Applications Application requisites Specific characteristics of the blower unit Premium Solutions for Gas and

More information

AIRBLAST CLIMATE CONTROL TUBE

AIRBLAST CLIMATE CONTROL TUBE OWNER S MANUAL AIRBLAST CLIMATE CONTROL TUBE IMPORTANT WARNING FOR SAFER BLAST CLEANING 1. Use protective equipment: Abrasive-resistant clothing, safety shoes, leather gloves, ear protection, CE-approved

More information

T208VR Series Tank Blanketing Vacuum Regulator

T208VR Series Tank Blanketing Vacuum Regulator February 2014 T208VR Series Tank Blanketing Vacuum Regulator Figure 1. Typical T208VR Series Vacuum Regulator Introduction The T208VR Series direct-operated vacuum regulators are used where a decrease

More information

Manual Solvent Purification System. Innovative Technology, Inc.

Manual Solvent Purification System. Innovative Technology, Inc. Innovative Technology, Inc. 2 New Pasture Road, Newburyport, MA 01950-4054 USA Email: Info@gloveboxes.com TEL: +1 978 462 4415 FAX: +1 978 462 3338 Manual Solvent Purification System Copyright Innovative

More information

Alkylphosphines. Storage and Handling Recommendations

Alkylphosphines. Storage and Handling Recommendations Alkylphosphines Storage and Handling Recommendations 2 The Phosphine Specialties Group has been producing phosphine and phosphine derivatives on a large scale for a number of years and the handling procedures

More information

School of Chemistry SOP For Operation Of Glove Boxes

School of Chemistry SOP For Operation Of Glove Boxes School SOP for Operation of Glove Boxes: The following SOP provides guidelines on how to adequately and safely operating a standard laboratory glove box and its associated devices. General Information:

More information

POWER FLUSH KIT INSTRUCTIONS

POWER FLUSH KIT INSTRUCTIONS 1 GENERAL INFORMATION POWER FLUSH KIT INSTRUCTIONS ACE Power Flush is an ozone-safe solvent engineered specifically for flushing refrigeration and air conditioning systems. Used exactly like the old R-11

More information

Glove Box Installation Manual

Glove Box Installation Manual Glove Box Installation Manual 1998 by M. Braun Company File: GB-UNI-INS.DOC! Edition 08-00 by M. Boutin! Subject to be changed without notice Glovebox Installation Your Glove box has been fully assembled,

More information

OXY Integral. INTERCON ENTERPRISES INC Tel: Fax: Internet:

OXY Integral. INTERCON ENTERPRISES INC Tel: Fax: Internet: OXY Integral INTERCON ENTERPRISES INC Tel: 800 665 6655 Fax: 604 946 5340 E-Mail: sales@intercononline.com Internet: www.intercononline.com Manual Integral 2006 1 INDEX 2-3 PREFACE 4 INTRODUCTION 5 Principle

More information

MATERIAL SAFETY DATA SHEET Eversafe Extinguisher Sdn. Bhd.

MATERIAL SAFETY DATA SHEET Eversafe Extinguisher Sdn. Bhd. MATERIAL SAFETY DATA SHEET Eversafe Extinguisher Sdn. Bhd. 1. PRODUCT AND COMPANY IDENTIFICATION Product Name : Eversafe Dry Powder Cartridge Operated Portable Fire Extinguisher EED-12cMX (Fire Extinguisher

More information

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DATA SHEET N 186 N 186.1.2 ST.12 E Concept The diaphragm pumps from KNF are based on a simple principle an elastic diaphragm, ixed on its edge, moves up and down

More information

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DATA SHEET N 186 N 186.1.2 ST.12 E Concept The diaphragm pumps from KNF are based on a simple principle an elastic diaphragm, ixed on its edge, moves up and down

More information

REF REF REF

REF REF REF VBM INFUSOR (500 ml / 1000 ml / 3000 ml) completely transparent 360 visible Wrap-Around Design with hook fl uid bag can be replaced quickly and easily consistent pressure on the complete fl uid bag Three-Way

More information

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DATASHEET N 143 N 143 SP.12 E Concept The diaphragm pumps from KNF are based on a simple principle an elastic diaphragm, ixed on its edge, moves up and down its central

More information

PRODUCT NUMBER: Rd40 Aluminium Canister HgP3

PRODUCT NUMBER: Rd40 Aluminium Canister HgP3 Europe / Africa PRODUCT NUMBER: 1784140 Rd40 Aluminium Canister HgP3 The HgP3 canister is part of the broad choice of canisters offered to protect against many hazardous gases, vapors and/or particulates

More information

Type R622 Pressure Reducing Regulator

Type R622 Pressure Reducing Regulator Type R622 Pressure Reducing Regulator June 2010 Compact Design Protective Inlet Screen High Capacity Internal Relief Light Weight W8806 Inlet and Outlet Pressure Gauge Taps Figure 1. Type R622 Pressure

More information

OPERATION MANUAL NTF-15

OPERATION MANUAL NTF-15 OPERATION MANUAL NTF-15 Nitrogen Tire Filling Valve Stem Caps (Qty=200) Order P/N 436075 RTI Technologies, Inc 10 Innovation Drive York, PA 17402 800-468-2321 www.rtitech.com 035-81235-00 (Rev B) TABLE

More information

SOUTH AFRICAN NATIONAL STANDARD

SOUTH AFRICAN NATIONAL STANDARD ISBN 978-0-626-24871-0 SOUTH AFRICAN NATIONAL STANDARD The selection, use and maintenance of respiratory protective equipment Published by SABS Standards Division 1 Dr Lategan Road Groenkloof Private Bag

More information

OPERATION MANUAL NTF-60 Plus

OPERATION MANUAL NTF-60 Plus OPERATION MANUAL NTF-60 Plus Nitrogen Tire Filling Valve Stem Caps (Qty=200) Order P/N 436075 RTI Technologies, Inc 10 Innovation Drive York, PA 17402 800-468-2321 www.rtitech.com 035-81264-00 (Rev A)

More information

Equipment Operating Procedure Glove Box

Equipment Operating Procedure Glove Box Equipment Operating Procedure Glove Box Page 1 0.0 Changing the Compressed Gas Cylinder 1. Complete Compressed Gas Cylinder training from EHS website before manually exchanging gas cylinders. In order

More information

Better to have one OXYLOG 3000

Better to have one OXYLOG 3000 MT-0852-2008 Better to have one OXYLOG 3000 Oxylog 3000 MT-676-2003 MT-1233-2004 MT-0741-2008 Time and time again, Dräger has contributed to major advances in emergency medicine with innovative masterpieces

More information

Unit 24: Applications of Pneumatics and Hydraulics

Unit 24: Applications of Pneumatics and Hydraulics Unit 24: Applications of Pneumatics and Hydraulics Unit code: J/601/1496 QCF level: 4 Credit value: 15 OUTCOME 2 TUTORIAL 9 ACCUMULATORS The material needed for outcome 2 is very extensive so there are

More information

PRESSURE REGULATOR LBM SERIES

PRESSURE REGULATOR LBM SERIES VIRTUAL CATALOGUE FAIL TO OPEN REGULATOR HIGH FLOW COEFFICIENT WIDE PRESSURE-REGULATION RANGE FAST RESPONSE PRESSURE REGULATOR LBM SERIES FULL SEAL AT ZERO FLOW CAN BE SUPPLIED WITH MINIMUM / MAXIMUM PRESSURE

More information

A B isothermal compression at a temperature of 300 K. The work done on the air is 104 J.

A B isothermal compression at a temperature of 300 K. The work done on the air is 104 J. Q1. In an ideal hot air engine, a fixed mass of air is continuously taken through the following four processes: A B isothermal compression at a temperature of 300 K. The work done on the air is 104 J.

More information

Cambridge Refrigeration Technology

Cambridge Refrigeration Technology Cambridge Refrigeration Technology www.crtech.co.uk. Guide to Sample Taking and Flame Testing Refrigeration Units and Bottles for Chlorine Contamination 8 th May 2013 Cambridge Refrigeration Technology

More information

Automatic watering Designing my project

Automatic watering Designing my project Automatic watering Designing my project www.rainbird.eu www.rainbird.eu Plants do not receive all the water they need from nature. An automatic watering system allows you: - To regularly provide water

More information

2B Technologies, Inc.

2B Technologies, Inc. 2B Technologies, Inc. An InDevR Company Technical Note No. 018 Cleaning Procedure for Model 202 Ozone Monitor Date: 22 September 2008; Updated 8 July 2016 Author: John Birks Summary: It is recommended

More information

Transferring and Storage

Transferring and Storage Organometallics Transferring and Storage A dip tube is available for Container 2 which can be screwed into the neck to permit safe transfer of product. Small quantities of metal alkyl can be withdrawn

More information

Spiromatic Face Mask and breathing valve User manual

Spiromatic Face Mask and breathing valve User manual Spiromatic Face Mask and breathing valve User manual Contents Safety notice... 4 Mask and breathing valve... 5 Checking before use Leakage test Putting on the mask... 7 Testing of the positive pressure

More information

Y692VB Series Vacuum Breaker

Y692VB Series Vacuum Breaker Y692VB Series Vacuum Breaker Bulletin 71.3:Y692VB June 2009 W7429 Figure 1. Type Y692VB Vacuum Breaker Introduction The Y692VB Series direct-operated vacuum breakers are used for the precise control of

More information

ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE

ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE ATEX CHEMISTRY DIAPHRAGM PUMPS. ATEX VARIO CHEMISTRY DIAPHRAGM PUMPS. Chemistry diaphragm pumps, vacuum systems and gauges for use in

More information

SERIES 30. Spring Operated Tank Blanketing Valve PROTECTOSEAL.

SERIES 30. Spring Operated Tank Blanketing Valve PROTECTOSEAL. SERIES 30 PROTECTOSEAL 1 2" NPT inlet and outlet standard Direct acting valve mechanism Optional flanged or threaded inlet and outlet connections available Inlet gas pressures from 10 PSIG to 200 PSIG

More information

Some Furnace Questions I received an from a podcast listener with some furnace related questions. Based on the nature of the questions I figured

Some Furnace Questions I received an  from a podcast listener with some furnace related questions. Based on the nature of the questions I figured Some Furnace Questions I received an email from a podcast listener with some furnace related questions. Based on the nature of the questions I figured it would be better to ask an experienced furnace tech.

More information

HighVac Pumps. High Vacuum Venturi Pumps. Modular Venturi Vacuum Pumps with Solenoid-Operated Vacuum and Blow-Off

HighVac Pumps. High Vacuum Venturi Pumps. Modular Venturi Vacuum Pumps with Solenoid-Operated Vacuum and Blow-Off Modular Venturi Vacuum Pumps with Solenoid-Operated Vacuum and Blow-Off Vaccon offers a High Vacuum Venturi Pump in a variety of performance ranges. Each HighVac Series Pump is capable of 29.5 Hg [999mbar]

More information

TYPE 2800E EXTERNALLY MOUNTED, GAS LUBRICATED, NON-CONTACTING, DOUBLE CARTRIDGE SEAL

TYPE 2800E EXTERNALLY MOUNTED, GAS LUBRICATED, NON-CONTACTING, DOUBLE CARTRIDGE SEAL A Seat/Mating Ring B Face/Primary Ring (inboard) C Spring D Face/Primary Ring (outboard) E O-Ring F Drive Collar G Setting Ring H Sleeve TYPE 2800E B A D C H E Spiral Groove Technology G F Product Description

More information

Assembly-, installation- and maintenance instruction manual for bladder accumulators IBV / EBV , top reparable

Assembly-, installation- and maintenance instruction manual for bladder accumulators IBV / EBV , top reparable Page 1 von 8 Assembly-, installation- and maintenance instruction manual for bladder accumulators IBV / EBV 100-575, top reparable Content Seite 0 Legend 2 1 Overview 2 2 Accumulator assembly and installation

More information

Emergency Mobile Unit Medicinal gases everywhere, always on time

Emergency Mobile Unit Medicinal gases everywhere, always on time Emergency Mobile Unit Medicinal gases everywhere, always on time EMU Emergency Mobile Unit service consider a full management of medicinal gases emergency situations inside hospitals in different steps:

More information

Dräger TSW Elephant Diving Equipment

Dräger TSW Elephant Diving Equipment Dräger TSW Elephant Diving Equipment The world s first universal diving harness integrating the rebreather provides you with all four diving components needed for water depths up to 24 meters: basic vest,

More information

SIG SOUTHERN INDUSTRIAL GAS SDN BHD

SIG SOUTHERN INDUSTRIAL GAS SDN BHD SIG SOUTHERN INDUSTRIAL GAS SDN BHD SAFETY DATA SHEET NITROGEN DIOXIDE IN NITROGEN BALANCE 1. CHEMICAL PRODUCT AND COMPANY IDENTIFICATION Product name Dioxide 5ppm in balance Synonyms - Chemical Formula

More information

FLUID POWER FLUID POWER EQUIPMENT TUTORIAL ACCUMULATORS. This work covers part of outcome 2 of the Edexcel standard module:

FLUID POWER FLUID POWER EQUIPMENT TUTORIAL ACCUMULATORS. This work covers part of outcome 2 of the Edexcel standard module: FLUID POWER FLUID POWER EQUIPMENT TUTORIAL ACCUMULATORS This work covers part of outcome 2 of the Edexcel standard module: UNIT 21746P APPLIED PNEUMATICS AND HYDRAULICS The material needed for outcome

More information

University of Minnesota Nano Center Standard Operating Procedure

University of Minnesota Nano Center Standard Operating Procedure University of Minnesota Nano Center Standard Operating Procedure Equipment Name: Controlled Atmosphere Glove Box Model: Labconco Protector Location: PAN 185 Badger Name: Not on Badger Revision Number:

More information

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DATASHEET N 2400 N 2400.15 ST.9 E Concept The diaphragm pumps from KNF arebased on a simple principle an elastic diaphragm, ixed on its edge, moves up and down its

More information

CHEMICALLY RESISTANT DIAPHRAGM GAS SAMPLING PUMPS

CHEMICALLY RESISTANT DIAPHRAGM GAS SAMPLING PUMPS CHEMICALLY RESISTANT DIAPHRAGM GAS SAMPLING PUMPS DATA SHEET N 922 N 922 FTE Concept The diaphragm pumps from KNF are based on a simple principle - an elastic diaphragm, ixed on its edge, moves up and

More information

THE POWERFUL LEAK DETECTOR FOR ALL APPLICATIONS IN POWER PLANTS

THE POWERFUL LEAK DETECTOR FOR ALL APPLICATIONS IN POWER PLANTS THE POWERFUL LEAK DETECTOR FOR ALL APPLICATIONS IN POWER PLANTS Use of HeliTest GEN for location of leaks on the steam circuit of a turbine of a working power plant INTRODUCTION Power plant turbines, regardless

More information

Yokogawa s Rotameter Pricelist

Yokogawa s Rotameter Pricelist Yokogawa s Rotameter Pricelist Variable Area Flowmeter Rotameter The Original Pricelist valid from April 2010 RGC1 without adjustment valve, metering tube = 75mm Rotameter Catalogue - page 10 0,2-1 RGC1000

More information

Huat Siang Hardware Sdn. Bhd. Wire Mesh. Steel Sheet Piles. 1 of 33

Huat Siang Hardware Sdn. Bhd. Wire Mesh. Steel Sheet Piles. 1 of 33 Huat Siang Hardware Sdn. Bhd. Wire Mesh Steel Sheet Piles 1 of 33 2 of 33 Rails Purlins 3 of 33 4 of 33 Plates Plates 5 of 33 Hollow Sections HOLLOW SECTIONS SUPPLIER IN MALAYSIA - Huat Siang Hardware

More information

Traysealer T 100. Tray packaging in the smallest space

Traysealer T 100. Tray packaging in the smallest space Traysealer T 100 Tray packaging in the smallest space MULTIVAC T 100 Traysealer T 100 Tray packaging in the smallest space The compact, semiautomatic Traysealer T 100 easily and economically packs products

More information

GENERAL CATALOGUE 2O16

GENERAL CATALOGUE 2O16 GENERAL CATALOGUE 2O16 LABORATORY TAPS INDEX TECHNICAL INFORMATION PAGES DRY SERVICE CONTROLS PAGES PRESENTATION TECHNICAL INFORMATION DESIGN AND MANUFACTURING 1 2-3 4 BENCH MOUNTED WALL MOUNTED PENDANT

More information

Operating Instructions UCA Charging & Gauging Kit. For use with Piston, Bladder & Diaphragm Accumulators. Hydraulics. Effective: 01 July 2001

Operating Instructions UCA Charging & Gauging Kit. For use with Piston, Bladder & Diaphragm Accumulators. Hydraulics. Effective: 01 July 2001 Operating Instructions Charging & Gauging Kit Effective: 01 July 2001 For use with Piston, Bladder & Diaphragm Accumulators Warning FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR

More information

Eco Snow CO2 Clean System Operation

Eco Snow CO2 Clean System Operation Eco Snow CO2 Clean System Operation This equipment is to be operated only by individuals that have been trained and qualified by the MNFC staff. Do NOT use or attempt to use this tool unless you are qualified

More information

Accessories. Differential pressure gauges for air and gas MAG-A & MAG-G (E5275 rev /04/2010)

Accessories. Differential pressure gauges for air and gas MAG-A & MAG-G (E5275 rev /04/2010) Accessories Differential pressure gauges for air and gas MAG-A & MAG-G (E5275 rev. 02-12/04/2010) GENERAL WARNINGS: DISPOSAL: ¾ All installation, maintenance, ignition and setting must be performed by

More information

Appendix: Simplified Instructions for Operating the HP 5890 GC/FID and Air Sampling Systems

Appendix: Simplified Instructions for Operating the HP 5890 GC/FID and Air Sampling Systems Appendix: Simplified Instructions for Operating the HP 5890 GC/FID and Air Sampling Systems The bucket brigade air sampler. For the square Tedlar bags with the push/pull valves: Put the valve of a tedlar

More information

Dräger MSI P7 Combustion Gas Analysis

Dräger MSI P7 Combustion Gas Analysis Dräger MSI P7 Combustion Gas Analysis Fit for the new DVGW-TRGI 2008: The Dräger MSI P7 provides several methods for you to test pipelines and containers that are filled with gas or air. The device has

More information

TOURNIQUET SYSTEMS & PRESSURE INFUSION

TOURNIQUET SYSTEMS & PRESSURE INFUSION TOURNIQUET SYSTEMS & PRESSURE INFUSION VBM Medizintechnik 1 INDEX ELECTRIC TOURNIQUETS... 4-7, 10 COMPRESSED AIR TOURNIQUETS... 8-9 MANUAL TOURNIQUETS... 11 TOURNIQUET CUFFS & ACCESSORIES... 13-15 BLOOD

More information

Background information. normal force on a surface area of the surface

Background information. normal force on a surface area of the surface Experiment 5a Class: Name: ( ) Date: 5a Boyle s law Objective To investigate the relationship between the pressure and volume of a fixed mass of gas at a constant temperature. Background information Pressure

More information

Control Units for Oil+Air Lubrication

Control Units for Oil+Air Lubrication Control Units for Oil+Air Lubrication 1-1700-3-US Universal Control Unit The control units described in this leaflet are used for timeor pulse-dependent control of oil+air systems. The overview shows the

More information

Instructions For Use USD3156. Kleenpak Capsule with Pegasus Protect Prefiltration Membrane

Instructions For Use USD3156. Kleenpak Capsule with Pegasus Protect Prefiltration Membrane Instructions For Use USD3156 Kleenpak Capsule with Pegasus Protect Prefiltration Membrane Mini Kleenpak Capsule Filterability Tools are for filter-sizing studies and evaluation during process development

More information

CHEMICALLY RESISTANT DIAPHRAGM GAS SAMPLING PUMPS

CHEMICALLY RESISTANT DIAPHRAGM GAS SAMPLING PUMPS CHEMICALLY RESISTANT DIAPHRAGM GAS SAMPLING PUMPS DATA SHEET N 9 N 9 FTE Concept The diaphragm pumps from KNF are based on a simple principle an elastic diaphragm, ixed on its edge, moves up and down its

More information

ALU-CD 12, ALU-CD 25, ALU-CD 35, ALU-CD

ALU-CD 12, ALU-CD 25, ALU-CD 35, ALU-CD Operating Manual ALU-CD 12, ALU-CD 25, ALU-CD 35, ALU-CD 50 und ALU-CD 60 KGW - ISOTHERM Gablonzer Straße 6 76185 Karlsruhe Germany Tel: 0049 / 721 95897-0 Fax: 0049 / 721 95897-77 Internet: www.kgw-isotherm.com

More information

Pneumatic Conveying Principles BSH&E SEMINAR

Pneumatic Conveying Principles BSH&E SEMINAR Pneumatic Conveying Principles Definition What is Pneumatic Conveying? A method for conveying bulk material using gas (usually air) The material can be blown (pressure systems) or sucked (vacuum systems)

More information

SECTION 11 VACUUM GRIPPER

SECTION 11 VACUUM GRIPPER VACUUM GRIPPERS SECTION VACUUM GRIPPER EDCO USA. www.edcousa.net : CONTENTS GENERAL INFORMATION ER L-Series Coaxial Venturi Technology : Centralized Systems : Operating Pressure : Discrete Systems :4 Rugged

More information

Dräger PAS Micro Short Term Breathing Apparatus

Dräger PAS Micro Short Term Breathing Apparatus Dräger PAS Micro Short Term Breathing Apparatus Combining versatility, ease of use and the latest in breathing apparatus design, Dräger s PAS Micro is among the most technologically advanced short duration

More information

Entry to these spaces must be rigorously controlled to prevent serious injury or death.

Entry to these spaces must be rigorously controlled to prevent serious injury or death. Chapter 6 - Confined Spaces Chapter 6 Confined Spaces Definitions A confined space is defined as any structure that must be entered and that has or may contain dangerous concentrations of hazardous gases

More information

Corning HYPERStack Cell Culture Vessel Closed System

Corning HYPERStack Cell Culture Vessel Closed System Corning HYPERStack Cell Culture Vessel Closed System User Guide Corning HYPERStack Vessel Components Liquid Handling Section F E B M D G B K J I A Liquid handling manifold B 3/8" I.D. liquid handling tubing

More information

Series ZFC. Air Suction Filter In-line Type with One-touch Fittings

Series ZFC. Air Suction Filter In-line Type with One-touch Fittings CAT.E832- A Air Suction Filter In-line Type with One-touch Fittings Series ZFC An in-line type air suction filter that prevents trouble in vacuum equipment due to contaminants in the air IN/OUT straight

More information

Pump out insert (condenser and still lines) overnight with turbo pump

Pump out insert (condenser and still lines) overnight with turbo pump Running the Dilution Fridge Before starting a run: Pump out insert (condenser and still lines) overnight with turbo pump Make sure LN and LHe traps are clean pump out with He4 rotary pump Start He3 rotary

More information

SPACE TRAVEL. Focus: ROCKETS UNDERSTANDING THE BASICS

SPACE TRAVEL. Focus: ROCKETS UNDERSTANDING THE BASICS UNDERSTANDING THE BASICS Rocket engines are different from car engines and steam engines, which produce rotary motion to drive wheels. Rocket engines produce thrust. The reaction of the fuel combusting

More information

4-7 kw/ hp. Dual Output Compressors (Air/Nitrogen) Driving Nitrogen Forward

4-7 kw/ hp. Dual Output Compressors (Air/Nitrogen) Driving Nitrogen Forward GN 4-7 kw/5.5-10 hp Dual Output Compressors (Air/Nitrogen) Driving Nitrogen Forward Total capability, total responsibility Right at the heart of your business, Atlas Copco delivers quality compressed air

More information

Type ACE95jr Tank Blanketing Valve

Type ACE95jr Tank Blanketing Valve Type ACE95jr Tank Blanketing Valve Features Fully Balanced Plug Design Reduces Inlet Pressure Sensitivity Bulletin 74.1:ACE95JR May 2010 Stainless Steel Construction Available High Sensitivity Self-Contained

More information

Manual. Online Degasser DDG-75. Manual Degasser DDG-75 April DURATEC Analysentechnik GmbH Rheinauer Strasse 4 DE Hockenheim Germany

Manual. Online Degasser DDG-75. Manual Degasser DDG-75 April DURATEC Analysentechnik GmbH Rheinauer Strasse 4 DE Hockenheim Germany Manual Degasser DDG-75 April 2007 1 Manual Online Degasser DDG-75 DURATEC Analysentechnik GmbH Rheinauer Strasse 4 DE-68766 Hockenheim Germany Tel. +49-6205-9450-0 Fax. +49-6205-9450-33 email info@duratec.com

More information

User manual STARLOCK. Careways International - Innovation Quality Performance

User manual STARLOCK. Careways International - Innovation Quality Performance EN User manual LOCK Careways International - Innovation Quality Performance Content About this manual... 3 The Starlock cushion... 4 1 Warnings... 5 2 Important parts... 6 3 Use... 8 3.1 The right amount

More information

May 2016 Med Tips. Helpful Hints and FAQs. Replacing AirSep VisionAire Mixing Tank

May 2016 Med Tips. Helpful Hints and FAQs. Replacing AirSep VisionAire Mixing Tank May 2016 Med Tips Helpful Hints and FAQs Replacing AirSep VisionAire Mixing Tank CAIRE offers a kit designed to allow the replacement of any mixing tank originally installed in the AirSep VisionAire 5

More information

/ /

/ / GN 4- kw/5.5-0 hp Dual Output Compressors (Air/Nitrogen) Driving Nitrogen Forward GN: the dual output solution From cargo blanketing in LNG vessels to the inflation of Formula tires, nitrogen is used in

More information

Types ACE95 and ACE95Sr Tank Blanketing Valves

Types ACE95 and ACE95Sr Tank Blanketing Valves Types ACE95 and ACE95Sr Tank Blanketing Valves Bulletin 74.1:ACE95 May 2010 W9133 W8155 Figure 1. Type ACE95 Tank Blanketing Valve Figure 2. Type ACE95Sr Tank Blanketing Valve Features Fully Balanced Pilot

More information

PRESCODEM400, PRESCODEM400/220

PRESCODEM400, PRESCODEM400/220 Sinorix PRESCODEM400, PRESCODEM400/220 Sinorix CDT-V, Sinorix H2O Jet Removable contact pressure gauge with electrical connector Allows to visually check the pressure of the cylinder on which it is mounted

More information

Approved by Principal Investigator Date: Approved by Super User: Date:

Approved by Principal Investigator Date: Approved by Super User: Date: Approved by Principal Investigator Date: Approved by Super User: Date: Standard Operating Procedure BNC OAI 200 Lithographic Mask Aligner (Aligner 3) Version 2011 June 2 I. Purpose This Standard Operating

More information

Mitos Fluika Pressure and Vacuum Pumps Datasheet

Mitos Fluika Pressure and Vacuum Pumps Datasheet Unit 1, Anglian Business Park, Orchard Road, Royston, Hertfordshire, SG8 5TW, UK T: +44 (0)1763 242491 F: +44 (0)1763 246125 E: sales@dolomite-microfluidics.com W: www.dolomite-microfluidics.com Dolomite

More information

PRESSURE REDUCING STATION INSTALLATION, OPERATIONS & MAINTENANCE MANUAL

PRESSURE REDUCING STATION INSTALLATION, OPERATIONS & MAINTENANCE MANUAL PRESSURE REDUCING STATION INSTALLATION, OPERATIONS & MAINTENANCE MANUAL Company Registered Office: Crown House, Stockport, Cheshire, SK13RB No. 850 0700 67 Registered in England and Wales No. 05058855

More information

MATERIAL SAFETY DATA SHEET. Product: PTFE/FEP

MATERIAL SAFETY DATA SHEET. Product: PTFE/FEP HYDRO SEALING TECHNOLOGY SDN BHD ( 426172-P ) ( Sales Tax ID No : J31-1808-21018370 ) No.5, Jalan Tiong Emas 4, Kawasan Perindustrian Tiong Nam, 81100, Johor Bahru, Johor, Malaysia. Tel : 07-362 0022 Fax

More information

Operating Manual ALU 7 - ALU 10 - ALU 20 - ALU 26 ALU 35 - ALU 60 - ALU 100

Operating Manual ALU 7 - ALU 10 - ALU 20 - ALU 26 ALU 35 - ALU 60 - ALU 100 Operating Manual ALU 7 - ALU 10 - ALU 20 - ALU 26 ALU 35 - ALU 60 - ALU 100 KGW - ISOTHERM Gablonzer Str. 6 76185 Karlsruhe Germany Tel: 0049 / 721 95897-0 Fax: 0049 / 721 95897-77 Internet: www.kgw-isotherm.com

More information