A Multiplexer System for Measurement of Gaseous Emissions
|
|
- Isaac Anderson
- 6 years ago
- Views:
Transcription
1 A Multiplexer System for Measurement of Gaseous Emissions Cale Boriack Ronald Lacey, Saqib Mukhtar Atilla Mutlu, Sergio Capareda Bryan Shaw, Calvin Parnell, Jr.
2 Objectives Develop a method to increase productivity when sampling during a field campaign Automate data collection
3 Overview Sampling Methodology System Design Benefits of using a multiplexer Concluding remarks
4 Sampling Methodology Flux chambers 30 minute 7L/min input 30 minute 7L/min input 2L/min drawn from chamber vented
5 Sampling Setup Zero Air Generator Zero Air Air Compressor Multiplexer Analyzer Chamber Lift Vent Flux Chamber
6 Sampling Setup
7 Sampling Setup
8 Sampling Protocol each management area within the facility Grids placed in management area with one sample point in each boxed grid point order is random point within the box is random
9 Example Small Open lot 12 Grid points Start time is 9:00 am 1 multiplexer setup 3 chambers
10 9:01 am
11 9:05 am
12 9:31 am
13 9:35 am
14 10:01 am
15 10:05 am
16 10:31 am
17 10:35 am
18 11:01 am
19 11:05 am
20 11:31 am
21 11:35 am
22 12:01 pm
23 12:05 pm
24 12:31 pm
25 12:35 pm
26 1:01 pm
27 1:05 pm
28 1:31 pm
29 1:35 pm
30 2:01 pm
31 2:05 pm
32 2:31 pm
33 3:01 pm
34 System Design 23 solenoid valves 3 mass flow controllers 1 Mass flow meter 3 Flow valves Control system Outdoor Enclosure
35 System NC Solenoid Valve Design Mass Flow Controller, 15 L/min MFC1 S1 S2 S3 Zero air to Chamber Zero Air Generator S4 MFC2 Mass Flow Controller, 15 L/min S5 S6 To Additional Analyzers for Calibration Pressure Regulator MFC3 S7 Static Mixing Element S17 Calibration Gas Mass Flow Controller, 5 L/min S18 S19 Pressure Regulator Backflow Valve S8 NO Solenoid Valve MFM1 S20 S21 S22 To Chamber Lift System Dryer/Water Separator S9 S10 S16 Mass Flowmeter Vacuum Pump S23 S11 Air Compressor FV 1 S12 Mass Flowmeter Analyzer Flow From Chamber FV2 FV 3 S13 S14 MFM2 Teflon Vacuum Pump Adjustable Flow Valve, 2 L/min S15
36 Chamber Process Input: Start Chamber Check =0 =0 =0 Chamber ( = 1) Controller Chamber Processes Check = 0 Yes Write =1, =0 No Chamber mfc1 mfc2 T(chamber) : : sum Choose MFC If MFC 1 = 0 Write mfc 1 = 1 Else write mfc 2 = 1 Write Time = {current time} Input data Output Process information Yes Check Time () {current time} <Time+30 min No Write =0 =1 Input data Output Process information Yes Check Time () {current time} <time +60 min Output Log and save Data No Write = 0 mfc 1 =0 mfc 2 =0 End
37 Benefits of Multiplexing Ability to use equipment at full capacity Increase data collection capacity Increase sampling rate
38 Results from No multiplexer (2002) 16 hr/day, 4 days 29 samples 1 multiplexer (2003) 16 hr/day, 4 days 55 samples 1 multiplexer (2004) 24 hr/day, 4 days 127 samples
39 Additional requirements Computer control Error checking Data management Additional manpower
40 Concluding remarks Multiplexing allows more efficient use of resources Results in a lower cost to sample Multiplexer may be applicable to other gas sampling processes
41 Ya ll comin In here? I think they are!
Hazards associated with the gas system and how to mitigate them
Hazards associated with the gas system and how to mitigate them Do not enter the gas shack if the rotating red light at the entrance is on. This warns of an oxygen deficiency. In General the Gas Mixing
More informationTitle: Standard Operating Procedure for Dasibi Model 5008 Gas Dilution Calibrator
Procedure No: SOP-034 Revision No: 1.0 Revised Dec. 29, 2010 Page No.: 1 of 10 1. INTRODUCTION AND SCOPE This procedure is intended to describe the operations of the Dasibi model 5008 calibrator. The Dasibi
More informationAppendix D: SOP of INNOVA 1412 Photoacoustic Multi-Gas Monitor. Description and Principle of Operation
Page 1 of 19 : SOP of INNOVA 1412 Photoacoustic Multi-Gas Monitor Description and Principle of Operation The photoacoustic multi-gas monitor (INNOVA 1412, Innova AirTech Instruments, Denmark) is a highly
More informationMarc McMullen. Physics Detector Support Group
Marc McMullen Physics Detector Support Group Hall B Gaseous Detectors 1. Drift Chamber (DC) 2. Low Threshold Cherenkov Counter (LTCC) 3. High Threshold Cherenkov Counter (HTCC) 4. Silicon Vertex Tracker
More informationGenerating Calibration Gas Standards
Technical Note 1001 Metronics Inc. Generating Calibration Gas Standards with Dynacal Permeation Devices Permeation devices provide an excellent method of producing known gas concentrations in the PPM and
More informationVOC Emissions From the Drying of Red Alder Lumber
VOC Emissions From the Drying of Red Alder Lumber Report to Cascade Hardwoods Report by Michael R. Milota Department of Wood Science and Engineering Oregon State University Corvallis, OR 97331 February
More informationCASE STUDY. Elvington To Brayton Barff Air valve replacement Program
CASE STUDY Elvington To Brayton Barff Air valve replacement Program Vent-O-Mat Anti-Shock Air valves have helped Yorkshire Water reduce maintenance costs, reduces surge and improve flows in their trunk
More information2. Determine how the mass transfer rate is affected by gas flow rate and liquid flow rate.
Goals for Gas Absorption Experiment: 1. Evaluate the performance of packed gas-liquid absorption tower. 2. Determine how the mass transfer rate is affected by gas flow rate and liquid flow rate. 3. Consider
More informationPROTOCOL January 25, 2008
PROTOCOL 08-0002 SouthMedic Oxymask and a Non-Rebreather Mask with 80-20 Heliox as Measured at the Mouth January 25, 2008 Dave Piper, PE Piper Medical Products PO Box 993 Carmichael, CA 95609 Tel 916-834-3283
More informationHumiSys HF High Flow RH Generator
HumiSys HF High Flow RH Generator Designed, built, and supported by InstruQuest Inc. Versatile Relative Humidity Generation and Multi-Sensor System The HumiSys HF is a high flow version of the previously
More informationPEAPOD. Pneumatically Energized Auto-throttled Pump Operated for a Developmental Upperstage. Test Readiness Review
PEAPOD Pneumatically Energized Auto-throttled Pump Operated for a Developmental Upperstage Test Readiness Review Customer: Special Aerospace Services Chris Webber and Tim Bulk 1 Overview Project Overview
More informationThe Discussion of this exercise covers the following points:
Exercise 5-3 Wet Reference Leg EXERCISE OBJECTIVE Learn to measure the level in a vessel using a wet reference leg. DISCUSSION OUTLINE The Discussion of this exercise covers the following points: Measuring
More informationliving with the lab control of salinity 2012 David Hall
control of salinity 2012 David Hall General Idea The objective is to keep the salinity close to a setpoint which will provided by your instructor The salinity sensor measures the analog voltage output
More informationINSTRUCTION MANUAL. FLOW CONTROL DRAWERS MANUAL / PLC CONTROL SERIES Model Version Perma Pure LLC Tel:
PERMA PURE INSTRUCTION MANUAL FLOW CONTROL DRAWERS MANUAL / PLC CONTROL SERIES Model 3300 Version 4.06 Perma Pure LLC Tel: 732-244-0010 P.O. Box 2105, 8 Executive Drive Tel: 800-337-3762 (toll free US)
More informationTitle: Standard Operating Procedure for Sabio 2010 and 4010 Dilution Calibrator
Procedure No: SOP-012 Revision No: 1.2, January 27, 2011 Page No.: 1 of 7 1. INTRODUCTION AND SCOPE This procedure is intended to describe the operations of the Sabio model 2010 and 4010 dilution calibrators.
More informationPegas 4000 MF Gas Mixer InstructionManual Columbus Instruments
Pegas 4000 MF Gas Mixer InstructionManual Contents I Table of Contents Foreword Part I Introduction 1 2 1 System overview... 2 2 Specifications... 3 Part II Installation 4 1 Rear panel connections...
More informationAutomatic Isokinetic Sampler. ST5 Evo
Automatic Isokinetic Sampler ST5 Evo Automatic Isokinetic Sampler ST5 Evo Moreover, in case of pump failure, the CU can work with a spare Dado PU unit or with any pump capable to supply the needed flowrate,
More informationFeatures. Main Voltage: Vdc. Input Control Signal: 0-5 Vdc or 4-20 madc (Sourcing) Monitor Output Voltage: 0-5 Vdc or 4-20 madc (Sourcing)
1 X-Flow Mass Flow Controller Flow Range from 0.8 ml/min to 20 l/min Target Markets Laboratory and Process Instrumentation Pharma / Bio-Pharma Equipment Air Quality Monitoring Systems Furnace and Coatings
More informationMETHOD 21 - DETERMINATION OF VOLATILE ORGANIC COMPOUND LEAKS. 1.2 Scope. This method is applicable for the
1151 METHOD 21 - DETERMINATION OF VOLATILE ORGANIC COMPOUND LEAKS 1.0 Scope and Application. 1.1 Analytes. Analyte Volatile Organic Compounds (VOC) CAS No. No CAS number assigned 1.2 Scope. This method
More informationExercise 2-2. Second-Order Interacting Processes EXERCISE OBJECTIVE DISCUSSION OUTLINE. The actual setup DISCUSSION
Exercise 2-2 Second-Order Interacting Processes EXERCISE OBJECTIVE Familiarize yourself with second-order interacting processes and experiment with the finer points of controller tuning to gain a deeper
More informationMCQ Gas Blender 100 Series 3 Channels Gas Mixer
Channels Gas Mixer Revision 1.8 October 2016 High Performance Digital Gas flow Gas Dilutor Blender & Gas for Mixing flow Mixing Gases System and Calibration Routines Technical Data Sheet Lab in a box From
More informationModel 601CV. Mass Flow Controller. Product Features:
Model 601CV Mass Flow Controller Porter s Model 601CV Series II Mass Flow Controller (MFCs) is designed for precise control of virtually all conventional process gases. The MFC consists of a thermal mass
More informationACCURATE PRESSURE MEASUREMENT FOR STEAM TURBINE PERFORMANCE TESTING
ACCURATE PRESSURE MEASUREMENT FOR STEAM TURBINE PERFORMANCE TESTING Blair Chalpin Charles A. Matthews Mechanical Design Engineer Product Support Manager Scanivalve Corp Scanivalve Corp Liberty Lake, WA
More informationIntelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter
Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter Overview C % ppm 4~20mA Analog Output ppb Power Supply 100~240 VAC mg/l Dimensions 96 x 96 x 132mm RS-485 Digital Output (for DC-5310-RS only)
More informationAPPLICATION OF TOOL SCIENCE TECHNIQUES TO IMPROVE TOOL EFFICIENCY FOR A DRY ETCH CLUSTER TOOL. Robert Havey Lixin Wang DongJin Kim
Proceedings of the 2011 Winter Simulation Conference S. Jain, R.R. Creasey, J. Himmelspach, K.P. White, and M. Fu, eds. APPLICATION OF TOOL SCIENCE TECHNIQUES TO IMPROVE TOOL EFFICIENCY FOR A DRY ETCH
More informationProcedure for Operating Columbia (Nevis) LHe Electron Bubble Chamber Cryostat. Version 5.1
Project: Novel Electron Bubble Particle Detector Procedure for Operating Columbia (Nevis) LHe Electron Bubble Chamber Cryostat Version 5.1 (Using side filling line) Hand Processed Changes HPC No. Date
More informationHovacal DATASHEET JUNHO 2013
Hovacal DATASHEET JUNHO 2013 Ho va Cal digital MF Calibration gas generator with integrated mass flow sensor HovaCAL digital MF The calibration gas generator with integrated mass flow sensor For the generation
More informationTrion PECVD SOP IMPORTANT: NO PLASTIC, TAPE, RESISTS, OR THERMAL PASTE ARE ALLOWED IN THE CHAMBER
Trion PECVD SOP IMPORTANT: NO PLASTIC, TAPE, RESISTS, OR THERMAL PASTE ARE ALLOWED IN THE CHAMBER CAUTION: THE CHAMBER PLATE GETS EXTREMELY HOT Start Up Procedure 1) Open bottle and regulator for Helium,
More informationThe HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.
The HumiSys RH Generator Designed, built, and supported by InstruQuest Inc. Versatile Relative Humidity Generation and Multi-Sensor System The new HumiSys with single or dual RH probes capabilities is
More informationAera Industrial MFC Product Guide. Innovative Control at Work
Aera Industrial MFC Product Guide Innovative Control at Work c o n t e n t s 2 what is a mass flow controller? 3 fundamentals of mass flow measurement 4 nomenclature 5 operating principle 5 digital mass
More informationanalytical bulk flow distance FLOW level pressure temperature industrial communication
analytical bulk flow distance level pressure temperature industrial communication isolv THERMAL MASS METER Measuring Principle Self-heated Sensor Reference Sensor isolv Thermal Mass Flow Meters have two
More informationAnalogue and Digital Mass Flow Meters and Controllers for Gases MASS-STREAM
Analogue and Digital Mass Flow Meters and Controllers for Gases MASS-STREAM M+W Instruments Your partner Key Facts M+W Instruments was founded in 1988 and has always specialised in thermal mass flow meters
More informationTitle: Standard Operating Procedure for R&R Environmental Devices Model MFC201 Gas Dilution Calibrator
Procedure No: SOP-029 Revision No: 1.1 (December 29, 2010) Page No.: 1 of 7 1. INTRODUCTION AND SCOPE To obtain timely data for the purpose of air quality assessment, air quality trend reporting, air quality
More informationCO 2. (R744) Service Station Presentation. Contents. Goals Basic functions Specification Recovery R477 Vacuum Charge Safety Other features Prototype
(R744) Service Station Presentation Contents Goals Basic functions Specification Recovery R477 Vacuum Charge Safety Other features Prototype Page 1 (R744) Service Station Goals Usability Full automatic
More informationFlamco Flamco-Fill STA Flamco-Fill STM
STA STM Typ STA 5936 Typ STM 5937 GB Installation and operating instructions 1999, 2 Contents GB UK Limited P.O. Box 9, Washway Lane, St. Helens, Merseyside WA10 6FE United Kingdom Telephone: 01744 744744
More informationModel of a Standard Operating Procedure (SOP) for SO 2 measurements with a UV fluorescence analyzer
Model of a Standard Operating Procedure (SOP) for SO 2 measurements with a UV fluorescence analyzer How to use this specimen SOP This model SOP aims at giving support to network operators in setting-up
More informationThermo Environmental 48C Carbon Monoxide QA Plan Section I Electronic Calibration Branch Responsibilities
Page 1 of 12 Thermo Environmental 48C Carbon Monoxide QA Plan Section I Electronic Calibration Branch Responsibilities Page 2 of 12 Table of Contents 2.9.1 SAMPLE EQUIPMENT...3 2.9.1.1 Selection and Procurement...3
More informationliving with the lab control of salinity 2012 David Hall
control of salinity 2012 David Hall General Idea The objective is to keep the salinity close to a setpoint which will be provided by your instructor The salinity sensor measures the analog voltage output
More informationLAMINAR FLAME SPEED ANALYSIS USING PIV (PARTICLE IMAGE VELOCIMETRY)
LAMINAR FLAME SPEED ANALYSIS USING PIV (PARTICLE IMAGE VELOCIMETRY) OPERATIONAL PROCEDURES Venue: Project Room, Hopkinson Lab, CUED Experimental date: 25 March 2008 Prepared by: Cheng Tung Chong (ctc31@camacuk)
More informationUniCEM. Continuous Emissions Monitoring System
UniCEM Continuous Emissions Monitoring System UniCEM Continuous Emissions Monitoring System The UniCEM system is an up to five channel field mount Continuous Emissions Monitoring System designed to continuously
More informationPumping Apparatus Driver/Operator Apparatus Testing. Chapter Test. Directions: Write the correct letter on the blank before each question.
Chapter 15 Test Name: Date: Directions: Write the correct letter on the blank before each question. Objective 1: Distinguish among preperformance tests for pumping apparatus. 1. Which standard is commonly
More informationCHAPTER 3 : AIR COMPRESSOR
CHAPTER 3 : AIR COMPRESSOR Robotic & Automation Department FACULTY OF MANUFACTURING ENGINEERING, UTeM Learning Objectives Identify types of compressors available Calculate air capacity rating of compressor
More informationModel 8000 Automated Sampler. Operations and Maintenance Manual
Model 8000 Automated Sampler Operations and Maintenance Manual Version 20.00 March 19, 2014 2014 ATEC, 9727 Cotharin Road, Malibu, CA 90265-2112 ATEC Model 8000 Toxic Air Sampler Limited Warranty Atmospheric
More informationPorter Analytical & Industrial Products
Porter Analytical & Industrial Products Porter Analytical & Industrial Products Engineered to Excel in Critical Applications The Porter Instrument Division of Parker Hannifin Corporation is a leading manufacturer
More informationPhysical Analysis Model Report
Physical Analysis Model Report Developed by The University of Kentucky and KYPIPE LLC Prepared for the National Institute of Hometown Security 368 N. Hwy 27 Somerset, KY 42503 November 19, 2012 This research
More informationSCS Field Revision No. 1.0 June 2001 STANDARD OPERATING PROCEDURE (SOP) FOR FIELD OPERATION OF THE SEQUENTIAL CYCLONE SAMPLER (SCS)
STANDARD OPERATING PROCEDURE (SOP) FOR FIELD OPERATION OF THE SEQUENTIAL CYCLONE SAMPLER (SCS) Prepared by: Vincent A. Dutkiewicz Date: Reviewed by: Volker A. Mohnen (PMTACS-NY QA Officer) Date: Approved
More informationcontrol of salinity Thanks to David Hall, from LWTL
control of salinity Thanks to David Hall, from LWTL DI water (0.0% NaCl) salt water (1.0% NaCl) General Idea The objective is to keep the salinity close to a setpoint which will be provided by your instructor
More informationUser Manual for the Mars Calibration Bench
User Manual for the Mars Calibration Bench Fall 2013 Table of Contents Table of Contents Table of Contents... iii Introduction... v Chapter 1: The Mars Calibration Bench... 1 What Is the Mars Calibration
More informationMass Flow Meter (MFM) for Gases
873 Mass Flow Meter (MFM) for Gases Direct flow measurement by MEMS- Technology for nominal flow rates from 1 ml N /min to 8 l N /min (N 2 ) High accuracy Short response time Compact design and digital
More informationDrift-Chamber Gas System Controls Development for the CEBAF Large Acceptance Spectrometer
Drift-Chamber Gas System Controls Development for the CEBAF Large Acceptance Spectrometer M. F. Vineyard, T. J. Carroll, and M. N. Lack Department of Physics University of Richmond, VA 23173 ABSTRACT The
More informationT004.BioTector TOC Analyzer Pressure and Flow Test failure analysis
March 2013 PAGE 1 of 5 T004.BioTector TOC Analyzer Pressure and Flow Test failure analysis Section 1: Pressure Test. Theory of operation. The Mass Flow Controller (MFC) in the BioTector is used to confirm
More informationCT433 - Machine Safety
Rockwell Automation On The Move May 16-17 2018 Milwaukee, WI CT433 - Machine Safety Performance Level Selection and Design Realization Jon Riemer Solution Architect Safety & Security Functional Safety
More informationModel 3400 Toxic Air Sampler. Operations and Maintenance Manual
Model 3400 Toxic Air Sampler Operations and Maintenance Manual Version 1.40 June 17, 2007 2007 ATEC, 9727 Cotharin Road, Malibu, CA 90265-2112 ATEC Model 3400 Toxic Air Sampler Limited Warranty Atmospheric
More informationThermo Scientific Model 146i Principle of Operation
Thermo Scientific Model 146i Principle of Operation The Model 146i Multi-gas Calibrator dilutes calibration gases to precise concentrations. The diluted gases are used to perform zero, precision and Level
More informationTHERMAL MASS FLOW MEASUREMENT FOR GASES
THERMAL MASS MEASUREMENT FOR GASES Make the Wise Choice. Choose Sage Flow Meters. A Commitment to Higher Performance SAGE METERING is a manufacturer of high performance Thermal Mass Flow Meters which measure
More informationThe Cyclone Tire Deflation & Inflation Tool
The Cyclone Tire Deflation & Inflation Tool How it works; This tool operates on compressed air that activates our patent pending venturi that creates a ultra-high vacuum, that draws the air from inside
More informationData Sheet T 8389 EN. Series 3730 and 3731 Types , , , and. EXPERTplus Valve Diagnostic
Data Sheet T 8389 EN Series 3730 and 3731 Types 3730-2, 3730-3, 3730-4, 3730-5 and Type 3731-3 Electropneumatic Positioners EXPERTplus Valve Diagnostic Application Positioner firmware to detect potential
More informationMETHOD 25A - DETERMINATION OF TOTAL GASEOUS ORGANIC CONCENTRATION USING A FLAME IONIZATION ANALYZER
1250 METHOD 25A - DETERMINATION OF TOTAL GASEOUS ORGANIC CONCENTRATION USING A FLAME IONIZATION ANALYZER 1.0 Scope and Application. 1.1 Analytes. Analyte CAS No. Sensitivity Total Organic Compounds N/A
More informationLab 3 Introduction to Quantitative Analysis: Pumps and Measurements of Flow
Georgia Institute of Technology School of Earth and Atmospheric Sciences EAS 4641, Spring 2008 Lab 3 Introduction to Quantitative Analysis: Pumps and Measurements of Flow Purpose of Lab 3: 1) To gain a
More informationH 2 O Bubble Chamber Superheated Active Target System. Safety and Systems Overview B. DiGiovine
H 2 O Bubble Chamber Superheated Active Target System Safety and Systems Overview B. DiGiovine Physics Division and Bubble Chambers April 2009 First Bubble Chamber Received Full Operation Authorization
More informationDF-550E PROCESS ANALYSERS APPLICATIONS FEATURES
PROCESS ANALYSERS DF-550E The DF-550E Nano Trace oxygen analyser is a Coulometric sensor based analyser designed to measure oxygen as a contaminant at ultra trace levels in ultra high purity electronic
More informationVacuum Pumpdown and Venting Procedure, CRaTER Thermal Vacuum System. Dwg. No
Rev. ECO Description Checked Approval Date 01 32- Release M. Smith Vacuum Pumpdown and Venting Procedure, CRaTER Thermal Vacuum System Dwg. No. 32-06003.05 Revision 01 June 18, 2007 1 1. Introduction 1.1.
More information6200E Installation Requirements
Requirements When purchasing a standalone 6200E unit with the calibrator, the analyzer will be supplied as three 19 rack mount units. Analyzer Converter Calibrator Included with the unit are two lengths
More informationTest Report # Rev 0. Adiabatic Compression With Constant Bleed Valve
Test Report # 30016558 Rev 0 Adiabatic Compression With Constant Bleed Valve Scope: This test report contains test data on the effects of adiabatic compression in nitrogen service on AP3600 diaphragm valves,
More informationBAROMETER PRESSURE STANDARD PRESSURE CONTROLLER
BAROMETER PRESSURE STANDARD PRESSURE CONTROLLER Features ±0.01% FS Measurement & Control Accuracy ±0.001% /ºC Thermal Stability Pressure Ranges from ±1 psid to 1200 psia Applications Barometric Measurement
More informationENS-200 Energy saving trainer
ENS-200 Energy saving trainer Find out about the essential aspects of energy efficiency in compressed air installations Save money Put it into practice Take care of the environment Get training www.smctraining.com
More informationProject Title: Pneumatic Exercise Machine
EEL 4924 Electrical Engineering Design (Senior Design) Preliminary Design Report 27 January 2011 Project Title: Pneumatic Exercise Machine Team Members: Name: Gino Tozzi Name: Seok Hyun (John) Yun Email:
More informationExercise 8. Closed-Loop Pressure Control, Proportional-Plus-Integral Mode EXERCISE OBJECTIVE
Exercise 8 Closed-Loop Pressure Control, EXERCISE OBJECTIVE To understand open and closed-loop pressure control; To learn how to sense the pressure in a pneumatic circuit; To control the pressure in a
More informationExercise 4-2. Centrifugal Pumps EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Pumps
Exercise 4-2 Centrifugal Pumps EXERCISE OBJECTIVE Familiarize yourself with the basics of liquid pumps, specifically with the basics of centrifugal pumps. DISCUSSION OUTLINE The Discussion of this exercise
More information8.1 Calibration of gas sensors
8.1 Calibration of gas sensors! CAUTION! Calibration gas handling and precautions Observe safety regulation and accident prevention regulations when using or handling test gases. Use test gases in well-ventilated
More informationMMS Mercury Monitoring System for Natural Gas
MMS Mercury Monitoring System for Natural Gas Natural gas often contains mercury at concentrations that vary from below 1 to above 10000 µg/m 3. Mercury is both toxic and potentially damaging: it can corrode
More information1.1 Equipment: substrate, wafer tweezers, metal targets 1.2 Personal Protective Equipment: nitrile gloves, safety glasses 1.
Nanomaster NSC-3000 DC Magnetron Sputter Tool Standard Operating Procedure Faculty Supervisor: Prof. Robert White, Mechanical Engineering (x72210) Safety Office: Peter Nowak x73246 (Just dial this directly
More informationISQB1 INTRINSICALLY SAFE ELECTRO-PNEUMATIC CONTROL VALVE INSTALLATION & MAINTENANCE INSTRUCTIONS HAZARDOUS AREA CLASSIFICATION
PROPORTION AIR ISQB1 INTRINSICALLY SAFE ELECTRO-PNEUMATIC CONTROL VALVE INSTALLATION & MAINTENANCE INSTRUCTIONS Hazardous area classification Description / identification General specifications Connection
More informationExercise 5-2. Bubblers EXERCISE OBJECTIVE DISCUSSION OUTLINE. Bubblers DISCUSSION. Learn to measure the level in a vessel using a bubbler.
Exercise 5-2 Bubblers EXERCISE OBJECTIVE Learn to measure the level in a vessel using a bubbler. DISCUSSION OUTLINE The Discussion of this exercise covers the following points: Bubblers How to measure
More informationCover Page for Lab Report Group Portion. Pump Performance
Cover Page for Lab Report Group Portion Pump Performance Prepared by Professor J. M. Cimbala, Penn State University Latest revision: 02 March 2012 Name 1: Name 2: Name 3: [Name 4: ] Date: Section number:
More informationChemical Feed Equipment Floor-Mounted Gas Dispenser - Series CH4200
Specification Bulletin (rev.01) Series CH4200 Chemical Feed Equipment Floor-Mounted Gas Dispenser - Series CH4200 Easy, fast& accurate digital with 11 points calibration Laser sensor offering actual feed
More informationExercise 2-3. Flow Rate and Velocity EXERCISE OBJECTIVE C C C
Exercise 2-3 EXERCISE OBJECTIVE C C C To describe the operation of a flow control valve; To establish the relationship between flow rate and velocity; To operate meter-in, meter-out, and bypass flow control
More information3/2-way valve, Series CD07 Qn= 1400 l/min pipe connection compressed air connection output: G 1/4 - M14x1,5 suitable for ATEX
/-way valve, Series CD07 Version Spool valve, zero overlap Sealing principle soft sealing Working pressure min./max. -0.95 bar / 0 bar Ambient temperature min./max. -5 C / +80 C Medium temperature min./max.
More informationIBEDA GAS MIXERS HIGHEST PRECISION FOR YOUR WELDING AND CUTTING PROCESSES
IBEDA GAS MIXERS HIGHEST PRECISION FOR YOUR WELDING AND CUTTING PROCESSES GAS SAFETY ENGINEERING GAS MANIFOLD SYSTEMS AUTOGENOUS ENGINEERING FLAME SPRAYING GAS MIXERS IBEDA GAS MIXERS FOR MANY AREAS OF
More informationACV-10 Automatic Control Valve
ACV-10 Automatic Control Valve Installation, Operation & Maintenance General: The Archer Instruments ACV-10 is a precision automatic feed rate control valve for use in vacuum systems feeding Chlorine,
More informationDF-310E PROCESS ANALYSERS APPLICATIONS FEATURES
PROCESS ANALYSERS DF-310E The DF-310E is a Coulometric sensor based oxygen analyzer designed to measure trace and percent level oxygen in pure and multi-gas backgrounds for process and quality control
More informationTechnical Service Bulletin March 2015 TSB142.01
Technical Service Bulletin March 2015 TSB142.01 Commissioning Procedure for HYDRAcap This Technical Service Bulletin provides information for commissioning of a HYDRAcap membrane system in a water treatment
More informationProtocol Gas Verification For Compressed Gas Cylinders Containing Either SO 2, NO or CO. Quality Assurance Plan/Standard Operating Procedure
Page 1 of 4 Protocol Gas Verification For Compressed Gas Cylinders Containing Either SO 2, NO or CO Quality Assurance Plan/Standard Operating Procedure Page 2 of 4 Table of Contents 2.3.6 Protocol Gas
More informationExperimental Investigation on Transient Response of Two Stage Pressure Relief Valve
Experimental Investigation on Transient Response of Two Stage Pressure Relief Valve Prof. Basavaraj V.HUBBALLI 1, Dr. Vilas B.SONDUR 2 1 Jain College of Engineering, Belagavi Karnataka, India, bvhubliabhi@gmail.com
More informationSubparts AA and BB - The Other RCRA Air Rules. Beginners aabb
Subparts AA and BB - The Other RCRA Air Rules Beginners aabb 1 Background Subpart AA - Process vents Subpart BB - Equipment leaks Subpart CC - Tanks, surface impoundments, containers. Also includes Subpart
More informationAC : MEASUREMENT OF HYDROGEN IN HELIUM FLOW
AC 2010-2145: MEASUREMENT OF HYDROGEN IN HELIUM FLOW Randy Buchanan, University of Southern Mississippi Christopher Winstead, University of Southern Mississippi Anton Netchaev, University of Southern Mississippi
More informationDURRIDGE STAINLESS STEEL SOIL GAS PROBE
DURRIDGE STAINLESS STEEL SOIL GAS PROBE CONTENTS 1. Introduction... 3 2. Placement... 3 3. Connection... 4 4 Measurement... 4 4.1 GRAB Protocol... 5 4.2 Continuous Monitoring... 6 4.3 Thoron Protocol...
More informationPlant Air Energy Saving
Compressor power Figures show reliable effects. Company A performance Electricity CO2 Cost 1400 kw We help you save energy. We help you to improve and standardize your equipment, and adopt new equipment.
More informationEZ-Boom 2010 Automated Application Control System Quick Reference Card INTRODUCTION
INTRODUCTION This figure shows the front panel of the EZ-Boom 2010 automated application control system. Status indicator Rate switch Rate Adjustment (Inc/Dec) switch Master switch Boom section switches
More informationRunning the LiCor 6400 Infra Red Gas Analyzer (IRGA) with 4 whole-plant cuvettes attached
Running the LiCor 6400 Infra Red Gas Analyzer (IRGA) with 4 whole-plant cuvettes attached Note: You must read the Primer manual Sections 1-6 before using the IRGA. The manual is located in the wall cabinet
More informationGP1 & GP2. Electropneumatic Regulators FOR PRESSURE CONTROL TO 1,000 PSI
GP1 & GP2 Electropneumatic Regulators FOR PRESSURE CONTROL TO 1, PSI GP1 & GP2 Functional Description The GP series control valve is an electronic pressure regulator designed to precisely control the pressure
More informationThe latest automotive systems require innovative leak test methods and fixturing.
Leak Testing Auto Parts The latest automotive systems require innovative leak test methods and fixturing. In the past, automobile manufacturers only required basic forms of leak testing to check standard
More informationSRL Series. Oil-less Scroll Air Compressors. Pharmaceutical. Research & Development. Food & Beverage. Chemical. Electronic
Pharmaceutical SRL Series Oil-less Scroll Air Compressors Research & Development Food & Beverage Chemical Electronic Hitachi Industrial Equipment Product Brochure Hitachi SRL Series scroll compressors
More informationDIAPHRAGM PUMPS WITH KNF STABILIZATION SYSTEM
DIAPHRAGM PUMPS WITH KNF STABILIZATION SYSTEM DATA SHEET E 037 N 940.5 APE as AC version in IP 54 N 940.5 APE-W with multi-voltage power supply input (As an option adjustable with potentiometer or by external
More informationAirCannonPlans.Com. High Powered Water Cannon
High Powered Water Cannon My friend and I had water wars with our neighbors back in middle school. Standard water balloons just weren't doing the job. We knew we needed something with more power. I originally
More information7250 Sys. Ruska Multi-Range Pressure Calibration System. GE Sensing & Inspection Technologies. Features. Applications
GE Sensing & Inspection Technologies 7250 Sys Ruska Multi-Range Pressure Calibration System Features Fully integrated multi-range pressure test and calibration systems Select either an eight range or the
More informationMV5: Automated concentration system
MV5: Automated concentration system Abstract LabTech MV5 is the latest automatic nitrogen evaporator developed by our R&D Team able to process up to 54 samples simultaneously. This advanced instrument
More informationDigital Mass Flow Meters and Controllers for Gases
Digital Mass Flow Meters and Controllers for Gases A Bronkhorst company. M+W Instruments. Your specialists for inline measurement WORTH KNOWING M+W Instruments was founded in 1988 and has always specialised
More informationTitle: Xactix XeF2 Etcher Semiconductor & Microsystems Fabrication Laboratory Revision: A Rev Date: 03/23/2016
Approved by: Process Engineer / / / / Equipment Engineer 1 SCOPE The purpose of this document is to detail the use of the Xactix XeF2 Etcher. All users are expected to have read and understood this document.
More informationUsers Guide for the CableSoft Software Package
Issue 1.4: January, 2007 REF: CABLESOFT SOFTWARE MANUAL.DOC Users Guide for the CableSoft Software Package For Use with the Modified IEC 60332-3 Chamber for Measuring Heat Release Rate and Smoke Production
More information