AMAT Centura PVD System Config
|
|
- Charles Hodge
- 5 years ago
- Views:
Transcription
1 System with 2 Al PVD Chambers Vintage: mid 1990 s Originally built by AMAT USA Refurbished in 2011 Set up for 200mm substrates De-installed and crated in USA Complete working system Re-install services available Tool Configuration Information OEM = Applied Materials (AMAT) Platform = Centura 5200 Qty 2 narrow body load-locks Chamber A and C are PVD chambers o Standard body o Aluminum deposition o 4 finger heater o With back side gas Chamber D is an mark II etch (set up as pre-clean) Chamber F is an orienter/degas chamber Support Equipment Included o Neslab HX-750 chiller o Ebara cold traps (3) o Ebara cryo compressor o Ebara dry vacuum pumps o Ebara turbo pumps and controllers (6) o Integrated smaller foot print AC controller and gen rack (single unit) o All required umbilical s Notes The system was originally built by AMAT so it is a common mainframe and standard chambers. It does have a few modifications: o It has an older mark II etch chamber acting at the Pre-clean chamber (more custom as amat uses the PC or PCII chamber). This can be easily removed and a PC chamber added if need be. o This system has a standard orienter degas chamber (currently the customer didn t use so not configured in the software, but physically it is there, just need to turn on in the software). o The customer ran a special substrate so the robot blade was modified note, on the blade, so very easy to get this back to standard AMAT configuration can replace the blade if need be. Page 1
2 o Chambers have a cold trap (aka water pump) and turbo pumps. This was a standard configuration option from AMAT allows more process gas to be used and longer times between regens, actually the water pump regens very quickly. AMAT serial is 2506 estimated vintage is mid 90 s platform type is centura I with rev II facilities (so typical centura I mainframe for PVD 5200 and facilities points of connections are along the rear) NOTE: This tool was originally running in a Toshiba Japan fab and the tool vacuum system was designed to reduce maintenance/pump re-generation time and also to provide faster pump downs and elimination of moisture (water) from the entire system. The critical chambers use a combination of Ebara cold traps (similar to cryo-pump but much reduced down time) and turbo pumps. Cold traps are similar to cryo-pumps: they use a cryo-compressor to chill and trap moisture (water vapor) on the walls of the trap. They do not use a charcoal element so they do not accumulate vapors that then require re-generation. In fact these cold traps almost never require re-generation effort, hence reduce down time and increase production time. These traps operate at a slightly higher temperature than cryo-pumps. They can handle much larger gas volumes compared to cryo-pumps. They also are a must if the customer wants to run O2 gas in the process. This tool also has a combination of cold trap-turbo pump on the transfer module. The load locks have turbo pumps (one for each). Vacuum design details here: This system has 6 turbo pumps and 3 cold traps total: -loadlock A; turbo pump only -loadlock B; turbo pump only -transfer chamber; turbo pump and cold trap -PVD chamber A; turbo pump and cold trap -PVD chamber C; turbo pump and cold trap -Etch chamber D; turbo pump only Page 2
3 Photos Note Ebara cold trap-turbo pump locations Page 3
4 Note turbo pump mounted on load-lock, one per load-lock Page 4
5 The following photos are when the refurbishment was taking place in 2011; Note: this was before the addition of the etch chamber in position D. Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
http://www.globalfoundriesusedequipment.com/iinfo.cfm?itemno=178359 Promos Tool ID EE-EWE-06 Serial No 409611 Model AMAT Maker DPS II Metal W Location EA-04-100 Main Body (Front) Main Body (Side) Main
More informationOLED vacuum deposition cluster system Sunicel Plus 400 / Plus 400L (Sunic Systems)
OLED vacuum deposition cluster system Sunicel Plus 400 / Plus 400L (Sunic Systems) Gen2 substrate size : 370 (+/- 0.2) mm x 470 (+/- 0.2) mm. Thickness : 0.55 to 2.0mm. Supports the following deposition
More informationLam Rainbow and TCP Product Status Checklist. System Type: Poly Etcher System Model: 4420 D.O.M.:
System Type: Poly Etcher System Model: 4420 D.O.M.: Serial number: 3943 CTC Number: 1150 Machine Hours: ~29,428 1. System Control Software: Classic Envision 2. System Control Software Rev: Envision 1.5
More informationChapter 2 General description of the system
Chapter 2 General description of the system This system is a high density plasma etching system having a C to C load-lock system and an ISM (Inductive Super Magnetron) plasma source. The system consists
More information5.1.3 Mechanical Hazards Drive assemblies have sufficient power to cause injury. Keep hands, fingers, clothing and tools clear of moving parts.
Approved by: Process Engineer / / / / Equipment Engineer 1 SCOPE The purpose of this document is to detail the use of the PE4400. All users are expected to have read and understood this document. It is
More informationUniversity of Minnesota, MN Nano Center Standard Operating Procedure
Equipment Name: HDPCVD Revision Number: 2 Badger Name: HDPCVD Revisionist: L. von Dissen Model: Advanced Vacuum Date: 10/25/2016 Apex SLR ICP Location: PAN, Bay 3 1 Description The Apex SLR ICP is a high
More informationVertical Parylene Coating System
Technical Specification Vertical Parylene Coating System Overview Our standard Parylene vertical coating system offers users a range of standard feature and options that will meet all needs. The standard
More informationOerlikon Sputtering Evaporator SOP
Oerlikon Sputtering Evaporator SOP Short UNT Cleanroom 1. Taking out sample holder from Transport Chamber : Log in FOM to access the software Go to the software and log in with user1 and password user1
More informationUniversity of MN, Minnesota Nano Center Standard Operating Procedure
Equipment Name: University of MN, Minnesota Nano Center Deep Trench Etcher Badger Name: deeptrench Revision Number: 9 Model: SLR -770 Sofware Version: CORTEX v4.5 Revisionists: Paul Kimani Location: Bay
More informationLeaks, contamination and closed loop control how RGAs make coating processes more profitable
Leaks, contamination and closed loop control how RGAs make coating processes more profitable Backup: What s an RGA Residual Gas Analyzer An instrument that is measuring the gas composition in a chamber
More informationMicroscopy Cryogenic WORKSTATION. Performance by Design
CRYO Microscopy Cryogenic WORKSTATION Optical cryostat for use in microscopy and spectroscopy Performance by Design RC102-CFM Microscopy Cryostat offers fast cooldown, high efficiency, excellent temperature
More informationAngstrom Dielectric Sputterer Operation Manual
Angstrom Dielectric Sputterer Operation Manual I. System overview The Angstrom Dielectric Sputterer (ADS) has a similar interface as the Angstrom metal sputterer. It has two screens, the process screen
More informationStandard Operating Procedure. For. PVD E-Beam
P a g e 1 Standard Operating Procedure For PVD E-Beam P a g e 2 Introduction The PVD Electron-Beam Evaporator (E-Beam) thin film deposition machine uses a magnetically guided and collimated stream of electrons
More informationIntroduction of Vacuum Science & Technology. Diffusion pumps used on the Calutron mass spectrometers during the Manhattan Project.
Introduction of Vacuum Science & Technology Diffusion pumps used on the Calutron mass spectrometers during the Manhattan Project. 1 What is a vacuum? 760 mm Hg Vacuum ATM A vacuum is defined as less than
More informationOXFORD PLASMALAB 80PLUS (CLOEY)
Arizona State University NanoFab OXFORD PLASMALAB 80PLUS (CLOEY) Rev D Table of Contents Contents Table of Contents...1 1. Purpose / Scope...2 2. Reference Documents...2 3. Equipment / Supplies / Material...2
More informationVACUUM CHAMBER PM OBJECTIVE: Vacuum Vacuum STS-RIE / ETCH CAVITY. Chamber. Vacuum CHAMBER WALL. 5 to 6 days. Procedure: particle issues.
BEFORE AFTER VACUUM CHAMBER PM TECHNIQUE MULTIPLEX ICP STS-RIE CHAMBER WALL CLEAN OBJECTIVE: TO EFFECTIVELY PM THE ETCH STS-RIE CHAMBER IN A TIMELY MANNER, WHILE IMPROVING TOOL RECOVERY AND PARTICLE PERFORMANCE
More informationPRC CO ² -LASER PRESENTATION
Page 1 of 7 PRC CO ² -LASER PRESENTATION GENERAL CHARACTERISTICS - Embedded PC104 Electronics with exchangeable software allowing very easy integration of customer specified functions: such as eg. specific
More informationVACUUM CHAMBER PM TECHNIQUE LAM 9400 POLY ETCH WET SCRUB
VACUUM CHAMBER PM TECHNIQUE LAM 9400 POLY ETCH WET SCRUB OBJECTIVE: TO EFFECTIVELY PM THE LAM 9400 POLY ETCH CHAMBER, AND THE ASSOCIATED PARTS, IN A TIMELY MANNER TO IMPROVE PARTICLE PERFORMANCE, REDUCE
More informationNanofabrication Facility: ECR Etcher SOP Rev. 01b, March 06. Standard Operating Procedure for PlasmaQuest ECR II Etching
Standard Operating Procedure for PlasmaQuest ECR II Etching Authors: Rev. 00: Al Schmalz, Vighen Pacradouni and Jeff Young, December 21, 1998 Rev. 01: Dr. Andras G. Pattantyus-Abraham, May 24, 2005 Rev.
More informationBEST KNOWN METHODS. Transpector XPR3 Gas Analysis System. 1 of 6 DESCRIPTION XPR3 APPLICATIONS PHYSICAL INSTALLATION
BEST KNOWN METHODS Transpector XPR3 Gas Analysis System DESCRIPTION The Transpector XPR3 is a third-generation, quadrupole-based residual gas analyzer that operates at PVD process pressures and is the
More informationSTS ICP-RIE. Scott Munro (2-4826,
STS ICP-RIE LOCATION: Plasma Etch Area PRIMARY TRAINER: Scott Munro (2-4826, email@address.com) 1. OVERVIEW The STS ICP-RIE is available to users who require deep anisotropic silicon etching with near
More informationRHIC CRYOGENIC SYSTEMS MAINTENANCE PROGRAM
RHIC CRYOGENIC SYSTEMS MAINTENANCE PROGRAM Brookhaven National Laboratory Major Plant Equipment Categories / Locations Compressor Refrigerator Service Buildings The Maintenance program is based on the
More informationHumiSys HF High Flow RH Generator
HumiSys HF High Flow RH Generator Designed, built, and supported by InstruQuest Inc. Versatile Relative Humidity Generation and Multi-Sensor System The HumiSys HF is a high flow version of the previously
More informationRC102 & RC110 Sample in Vacuum Continuous Flow Cryogenic Workstation Cryostats
RC102 & RC110 Sample in Vacuum Continuous Flow Cryogenic Workstation Cryostats www.cryoindustries.com INDUSTRIES RC102 & RC110 Sample in Vacuum Continuous Flow Cryogenic Workstation Cryostats Designed
More informationShort Introduction to Cryo-Pumps and Refrigerators. Dr Graham Rogers Leybold UK Ltd.
Short Introduction to Cryo-Pumps and Refrigerators Dr Graham Rogers Leybold UK Ltd. Cryo Pumps Topics Physical principles of cryo-pumping Design and control of modern refrigerator cryo-pumps UHV and XHV
More informationThe HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.
The HumiSys RH Generator Designed, built, and supported by InstruQuest Inc. Versatile Relative Humidity Generation and Multi-Sensor System The new HumiSys with single or dual RH probes capabilities is
More informationCustomer Responsibilities
Thank you for purchasing an Agilent instrument. To get you started and to assure a successful and timely installation, please refer to this specification or set of requirements. Correct site preparation
More informationMANUAL FOR SPTS APS (DIELECTRICS ETCHER)
MANUAL FOR SPTS APS (DIELECTRICS ETCHER) To be read first: SPTS APS is an etcher dedicated to dielectrics (SiO 2, Si 3 N 4, glass types...). Dielectrics etching in AMS200 is no more CMi standard. AMS200
More informationNotes-PECVD: Chamber 1
plasmatherm (EML) STANDARD OPERATING PROCEDURE CORAL Name: Plasmatherm Model Shuttlelock System VII SLR-770/734 Number: Location: EML What it Deposits the following films via Plasma-Enhanced Chemical Vapor
More informationPLASMA ENHANCED CHEMICAL VAPOR DEPOSITION (PECVD) SOP OXFORD PLASMALAB SYSTEM 100
PLASMA ENHANCED CHEMICAL VAPOR DEPOSITION (PECVD) SOP OXFORD PLASMALAB SYSTEM 100 June 2013 Interface Overview. The Oxford software is divided into 5 main screens. 1) Pump Control page 2) Recipe page 3)
More informationIndian Institute of Technology Kanpur Samtel Centre for Display Technologies
Fax: + 91-0512-2596620 Phones: + 91-0512-2596622,6088 Indian Institute of Technology Kanpur Samtel Centre for Display Technologies Enquiry number: SCDT/FlexE/2016-17/02 Date:05/05/2016 Sealed Quotations
More informationHELIX. On-Board IS Cryopump Installation Instructions
HELIX On-Board IS Cryopump Installation Instructions 2005 Helix Technology CorporationPart Number 8040596, Revision 12, 03/29/05 ECO Number 17066 Printed in USA HELIX TECHNOLOGY CORPORATION http://www.helixtechnology.com
More informationUnifilm Technology PVD-300 Sputter Deposition Operation Instructions
Unifilm Technology PVD-300 Sputter Deposition Operation Instructions Contributors: Devin Brown, Kevin Klein, Ben King, Eric Woods Anything that is BOLD UNDERLINED ITALICS means that you should press that
More informationPRad Target. Chris Keith JLab Target Group
PRad Target Chris Keith JLab Target Group Target Overview & Components Target Software Hazard Analysis and Mitigation Target Status, Performance& Remaining Work Installation Schedule Nov. 12, 2015 PRad
More informationStandard Operating Manual
Standard Operating Manual Denton Explorer 14 RF/DC Sputter Version 1.0 Page 1 of 11 Contents 1. Picture and Location 2. Process Capabilities 1. Cleanliness Standard 2. Available for Sputtering Materials
More informationB. Assemble the Method-25 sample train with a heated probe/filter.
6/30/2015 VOC Reporting, Inc. Method 25 Heated Controller Operating Instructions. pg. 1 of 5 INSTRUCTIONS FOR EPA METHOD-25 FIELD SAMPLE COLLECTION USING A VRi HEATED PROBE AND FILTER ASSEMBLY Introduction:
More informationEdge Isolation Tool. Standard Operating Procedure. Version 1.1. Date: Prepared by, Sandeep S S. Department of Electrical Engineering
Edge Isolation Tool Standard Operating Procedure Version 1.1 Date: 20-9-2012 Prepared by, Sandeep S S Department of Electrical Engineering IIT Bombay This document is meant for internal circulation only
More informationCompressor Seal Replacement and Upgrades SERVICES
Compressor Seal Replacement and Upgrades SERVICES Compressor Seal Upgrades An Elliott Group compressor seal upgrade increases seal reliability and reduces process gas leakage to improve overall efficiency.
More informationCustomer Responsibilities. Important Customer Information Series Q-TOF LC/MS Systems Site Preparation Checklist
Thank you for purchasing an Agilent system. To get you started and to assure a successful and timely installation, please refer to this specification or set of requirements. Correct site preparation is
More informationStandard Operating Manual
Standard Operating Manual Oxford Plasmalab 80 Plus Plasma Etcher Page 1 of 24 Contents 1. Picture and Location 2. Process Capabilities 2.1 Cleanliness Standard 2.2 Available Etching Materials 2.3 Performance
More informationCustomer Responsibilities
Thank you for purchasing an Agilent instrument. To get you started and to assure a successful and timely installation, please refer to this specification or set of requirements. Correct site preparation
More informationIMPALA CONTROL PANEL CONVERSION KIT an ISO 9001:2008 Registered Company REV E 4/13/ IMPALA CNTRL PNL INST PG 1 OF 16
an ISO 9001:2008 Registered Company 1961-62 IMPALA CONTROL PANEL CONVERSION KIT 471062 20 30 40 50 60 70 80 90 100 110 120 C T E M P EF F U E L DEF AIR 901064 REV E 4/13/15 1961-62 IMPALA CNTRL PNL INST
More informationNITROGEN PURGING SYSTEMS FOR THE HVAC INDUSTRY VISION INNOVATION SOLUTION
NITROGEN PURGING SYSTEMS FOR THE HVAC INDUSTRY The Purge-N2-Test is a nitrogen regulator/cylinder system, utilizing a lightweight aluminum cylinder and a state of the art regulator with an integrated cylinder
More informationThe HumiPyc ( Model 2) - Gas Pycnometer; Density, Moisture, Permeation Analyzer; Filter Integrity Tester; RH sensor Calibrator
The HumiPyc ( Model 2) - Gas Pycnometer; Density, Moisture, Permeation Analyzer; Filter Integrity Tester; RH sensor Calibrator Designed, built, and supported by InstruQuest Inc. Universal pycnometer, no
More informationOxford Instruments Plasma Technology
Oxford Instruments Plasma Technology Issue 01_0D / December 2014 / www.oxford-instruments.com 2014. Oxford Instruments Plasma Technology. All rights reserved. Contents Section Page About this data sheet...
More informationTHERMAL EVAPORATION UNIT (for Al evaporation)
THERMAL EVAPORATION UNIT (for Al evaporation) System Owner: NeerajPanwar 9619507210 panwar.iitr@gmail.com System Operator: 1. Bhimraj Sable 9930189878 bhimrajsable71@gmail.com Authorized User: 1. Ramesh
More informationSNS BL-13B NPDGamma Experiment
SNS BL-13B NPDGamma Experiment Hydrogen Supply to Cryogenic Target, Relief and Vent System Design Review April 7, 2010 C-156 9:00 10:30 PM Hydrogen System Block Diagram Diagram of Major System Components
More informationHEATEC TEC-NOTE Publication No Revised
HEATEC TEC-NOTE Revised 6-17-10 Setting up Vega radar sensors for Heatec vertical asphalt tanks This document provides information for setting up Vega radar sensors installed on Heatec tanks that store
More informationCOMELEC C-30-S Parylene Coating System
COMELEC C-30-S Parylene Coating System Comelec C-30-S Parylene deposition system Introduction Parylene is a polymere deposited at room temperature in a vacuum chamber (few µb). Parylene coating is perfectly
More informationSTS DRIE User SOP Location: NRF Cleanroon, Dry Etch Bay
Page 1 of 20 STS DRIE User SOP Location: NRF Cleanroon, Dry Etch Bay Page 2 of 20 STS DRIE SOP The STS DRIE is an Inductively Coupled Plasma Process etcher designed and configured to etch deep high aspect
More informationSPUTTER STATION STANDARD OPERATING PROCEDURE
SPUTTER STATION STANDARD OPERATING PROCEDURE Purpose of this Instrument: This instrument is used for deposition of thin metal or oxide films. Source materials supplied by WVU Shared Research Facilities:
More informationNanofabrication Facility: Sputter Evaporator SOP Rev. 04, June 2007
Author: Rev. 00: David Webster, TRIUMF, February 22, 1995. Rev. 01: A. Schmalz, October 12, 1999 Rev. 02: Doug Wong, August 2, 2002 (STS File: S02-014) Rev. 03: Mario Beaudoin, April 2006 Rev. 04: Bahador
More informationCustomer Responsibilities
Thank you for purchasing an Agilent instrument. To get you started and to assure a successful and timely installation, please refer to this specification or set of requirements. Correct site preparation
More informationOxford Instruments Austin, Inc.
User's User s Manual Issue 01 / March 2013 / OIAI Cryo-Plex 10 Oxford Instruments Austin, Inc. Issue 01 / March 2013 / Original Instructions Oxford Instruments Austin, Inc. is a wholly-owned subsidiary
More informationVacuum Systems and Cryogenics for Integrated Circuit Fabrication Technology 01
INAOE. Tonantzintla, Mexico. 2010-06-23. June 23 rd, 2010 Vacuum Systems and Cryogenics for Integrated Circuit Fabrication Technology 01 Joel Molina INAOE Microelectronics Group jmolina@inaoep.mx 1 Vacuum
More informationSavannah S100 ALD at SCIF, UC Merced Standard operating Procedure
This document covers the procedure that should be followed for normal operation of the Cambridge NanoTech: Savannah S100 (Atomic Layer Deposition ALD). This tool is design to be used with whole 4inch wafers.
More informationKinetics Fluid Systems - Process Flow Products. 18 February
18 February 2002 1 THE MODULAR SYSTEM - History 1995 -Unit Instruments, Inc. introduced Z-Z Block Modular system for Semiconductor marketplace 1997 - Increasing acceptance of modular technology in semiconductor
More informationTIPPMANN MODEL 98 f/x
TIPPMANN MODEL 98 f/x OWNER'S GUIDE SUPPLEMENT PRO-TEAM PRODUCTS, INC. Technical Information: (904) 439-3600 Fax: (904) 439-0064 Tech@proteamproducts.com This document is to be used in conjunction with
More informationIssue: H Title: CHA E-Beam Evaporator Page 1 of 7. Table of Contents
Title: CHA E-Beam Evaporator Page 1 of 7 Table of Contents Purpose/Scope... 2 2.0 Reference Documents... 2 3.0 Equipment/Supplies/Material... 2 4.0 Safety... 2 5.0 Set Up Procedures... 2 5.1 PC Logon and
More informationStandard Operating Manual
Standard Operating Manual ARC12M Sputter Copyright 11.2015 by Hong Kong University of Science & Technology. All rights reserved. Page 1 Contents 1. Picture and Location 2. Process Capabilities 2.1 Cleanliness
More informationThe HumiPyc - Model 1 - Gas Pycnometer; Density, Moisture, Permeation Analyzer; RH sensor Calibrator
The HumiPyc - Model 1 - Gas Pycnometer; Density, Moisture, Permeation Analyzer; RH sensor Calibrator Designed, built, and supported by InstruQuest Inc. Temperature controlled, multi-technique volumetric
More informationOn-Board Waterpump Installation and Maintenance Instructions
On-Board Waterpump Installation and Maintenance Instructions 8040364 Revision AA On-Board Waterpump Cryo-Torr 8600 Compressor Operation, Installation and Maintenance Guide Information provided within this
More informationMMRC PVD Evaporator Instructions
Warnings MMRC PVD Evaporator Instructions (Updated Aug 2016) Under PVD conditions, even oils and greases are volatile. WEAR GLOVES, and if you touch your skin or anything else oily or wet, change them.
More informationApproved by Principal Investigator Date: Approved by Super User: Date:
Approved by Principal Investigator Date: Approved by Super User: Date: Standard Operating Procedure BNC Commonwealth Dual Ion Beam Deposition System (CDIBS) Version 2010 February 14 I. Purpose This Standard
More informationGun Safety Rules And Safe Range Operations
Gun Safety Rules And Safe Range Operations Knowledge Skill Attitude Safety is the number one priority on and off the range. Everyone must do their part to prevent accidents. In this sport, most incidents
More informationOxford Instruments Austin, Inc.
User User Manual Manual Issue 01 / November 2013 / Oxford Instruments Austin, Inc. Issue 01 / November 2013 / Original Instructions Original Instructions Issue 01 / November 2013 / Oxford Instruments Austin,
More informationActive Pulse Pressure Compensator APPC
PRODUCT DESCRIPTION: Design layout Cabinet mounted Active Pulse Pressure Compensator system. The system is installed to reduce/ eliminate surge pressure in firewater system caused by late fire pump start
More informationField Installed Options: * Louvered or non-louvered ceiling access panels. * Time delay relay.
Description: The High Efficiency Series air handlers are engineered to achieve or exceed today s demanding energy rating requirements. Specifically designed for horizontal mounting into a furred down ceiling.
More informationXactix Xenon Difluoride Etcher
Xactix Xenon Difluoride Etcher 1 Introduction This tool is a Xactix e1 series XeF2 (Xenon Difluoride) based vapor phase etch system for isotropic and selective silicon etching. The XeF2 reaction with silicon
More informationThe SPI Sputter Coater Handbook
The SPI Sputter Coater Handbook Coating of Specimens SPI-Module Sputter Coater with Etch Mode 1. Mount the specimens onto the SEM stub. Keep in mind that many adhesives have high vapor pressure solvents
More informationUsage Policies Notebook for AMST Molecular Vapor Deposition System MVD 100
Usage Policies Notebook for AMST Molecular Vapor Deposition System MVD 100 Revision date September 2014 2 Emergency Plan for AMST MVD 100 Standard Operating Procedures for Emergencies Contact information
More informationMarch CS-1701F Reactive Ion Etcher
March CS-1701F Reactive Ion Etcher Standard Operating Procedure Faculty Supervisor: Prof. Robert White, Mechanical Engineering (x72210) Safety Office: Peter Nowak x73246 (Just dial this directly on any
More informationNordiko Metal Sputtering System Standard Operating Procedure
Nordiko Metal Sputtering System Standard Operating Procedure Specifications : Target Size Gases used in the system Base pressure Sputtering pressure Substrates used Substrate size : 2 inch or 4 inch :
More informationOperating Procedures for the. SAMCO ICP RIE System
Operating Procedures for the SAMCO ICP RIE System General Overview: The purpose of the SAMCO Model 200iP Inductively Coupled Plasma Reactive Ion Etcher (ICP RIE) is to etch III-V compound semiconductors
More informationREPORT, RE0813, MIL, ENV, 810G, TEMP, IN HOUSE, , PASS
REPORT, RE0813, MIL, ENV, 810G, TEMP, IN HOUSE, TST 00191 REV. A Crystal Group Inc 850 Kacena Rd., Hiawatha, IA Phone: 877 279 7863 Fax: 319 393 2338 9/23/2014 Revision History REV Date Approved Description
More informationINSTRUCTION MANUAL FOR UNDERWATER OPERATION
INSTRUCTION MANUAL FOR UNDERWATER OPERATION FOR HYDRAULIC HAMMER MODELS: H3XA, H4XE/4XL, H6XA, H7X Use Genuine NPK Parts 7550 Independence Drive Walton Hills, OH 44146-5541 Phone (440) 232-7900 Toll-free
More information1)! DO NOT PROCEED BEYOND THIS MARK
Operating Instructions for X-ray Photoelectron Spectrometer: Physical Electronics Model 555 XPS/AES (John H. Thomas, III, Ph.D., Electron Spectroscopy) Sample Insertion: figure 1. Sample insertion rod
More information1.1 Equipment: substrate, wafer tweezers, metal targets 1.2 Personal Protective Equipment: nitrile gloves, safety glasses 1.
Nanomaster NSC-3000 DC Magnetron Sputter Tool Standard Operating Procedure Faculty Supervisor: Prof. Robert White, Mechanical Engineering (x72210) Safety Office: Peter Nowak x73246 (Just dial this directly
More informationCambridge NanoTech: Savannah S100. Table of Contents
Table of Contents 1.0 Purpose/Scope... 2 2.0 Reference Documents... 2 3.0 Equipment/Supplies/Material... 2 4.0 Safety... 2 5.0 Logbook... 3 6.0 Login and Launch Software... 3 7.0 Session Setup... 3 8.0
More informationBasic ICP Operating Procedures
Center for High Technology Materials 2 February, 2009 University of New Mexico Created by Beth Fuchs Basic ICP Operating Procedures INTRODUCTION: The ICP is an inductively coupled plasma etching system,
More informationMethods for Measuring Groundwater Elevation and Vacuum Pressure During Soil Vapor Extraction
Technical Note Methods for Measuring Groundwater Elevation and Vacuum Pressure During Soil Vapor Extraction Introduction Soil vapor extraction (SVE) is an easy and low-cost remediation method for removing
More informationArizona State University Center for Solid State Electronic Research. Table of Contents. Issue: C Title: Oxford Plasmalab 80plus (Floey) Page 1 of 8
Title: Oxford Plasmalab 80plus (Floey) Page 1 of 8 Table of Contents 1.0 Purpose/Scope... 2 2.0 Reference Documents... 2 3.0 Equipment/Supplies/Material... 2 4.0 Safety... 2 5.0 Set Up Procedures... 2
More informationMatching Vacuum Pump to Process
A Journal of Practical and Useful Vacuum Technology From By Phil Danielson Matching Vacuum Pump to Process What s the best vacuum pump? is one of those maddening questions that can only be answered with
More informationSINGULUS TECHNOLOGIES
Fast Vacuum for Optical Disc Metallization and Photovoltaic Coatings B. Cord, M. Hoffmann, O. Hohn, F. Martin SINGULUS Technologies AG, Kahl am Main SINGULUS TECHNOLOGIES June 2014 SINGULUS Overview 25-June-2014-2
More informationAirflow Options for Cisco MDS 9396S SAN Switch
Airflow Options for Cisco MDS 9396S SAN Switch This document describes how to configure, administer and troubleshoot airflow options in the MDS 9396S switch. Anyone can use this document along with hardware
More informationOPERATION MANUAL RTI RHS650 RTI TECHNOLOGIES, INC East Market Street York, PA Manual P/N
OPERATION MANUAL RTI RHS650 RTI TECHNOLOGIES, INC. 4075 East Market Street York, PA 17402 Manual P/N 035-80589-02 Table of Contents Components... 2 Test... 4 Recovery/Recycling... 5 Evacuation... 7 Charging...
More informationThermo K-Alpha XPS Standard Operating Procedure
Thermo K-Alpha XPS Standard Operating Procedure Quick Guide Draft v.0.1 Procedure overview 1. Vent the loadlock 2. Secure your sample to the stage using clips, check the height of the final assembly. 3.
More informationCaptains Meeting 2009 Introduction to Well Testing- Expro. Edwin Schoorl
Captains Meeting 2009 Introduction to Well Testing- Expro Edwin Schoorl Agenda Oil and Gas presence Well construction Well testing Welltest System Welltest Equipment Welltest Video Questions Oil and gas
More informationQuartz etch process to improve etch depth linearity and uniformity using Mask Etcher IV
Quartz etch process to improve etch depth linearity and uniformity using Mask Etcher IV Sunil Srinivasan *, Jason Plumhoff, Russ Westerman, Dave Johnson, Chris Constantine Unaxis USA, Inc. 10050 16 th
More information3M Steri-Vac Sterilizer/Aerator GSX Series. For Life Science Applications. Product. Profile
M Steri-Vac Sterilizer/Aerator GSX Series Product Profile Product Profile M Steri-Vac Sterilizer/Aerator GSX Series ethylene oxide (EO) sterilizer/aerators are designed to be used with M Steri-Gas EO Gas
More informationDisplacement 12, , Maximum flow rate (at 1450 rpm) bar.
00/07 ED PVD VARIABLE DISPLACEMENT VANE PUMPS SERIES 0 OPERATING PRINCIPLE The PVD pumps are variable displacement vane pumps with a mechanical type of pressure compensator. They allow instantaneous adjustment
More informationAngstrom E-Beam Instructions. PROCESS CHECKS: the tooling factors of each metal; Ti/Au layer for wire bonding pull test.
Angstrom E-Beam Instructions Tool Manager: Joe Palmer (jpalmer@princeton.edu) Office: 8-4706; Cell:609-751-1353 Backup: David Barth (dbarth@princeton.edu) Office: 8-4626; Cell: 610-405-8227 PROCESS CHECKS:
More informationMarch Asher Operation
March Asher Operation Roger Robbins 7/31/2006 The University of Texas at Dallas Erik Jonsson Engineering School of Engineering TITLE: March Asher Operation Page 1 of 13 March Asher Operation Roger Robbins
More informationTrillium US Inc. Cryo-Plex 10 Cryogenic High Vacuum Pump User s Manual Rev A / November 2015
97-00032-000 Trillium US Inc. Cryo-Plex 10 Cryogenic High Vacuum Pump User s Manual Rev A / November 2015 For information about Trillium US Inc., visit the Trillium US Inc. Web site at: http://www.trilliumus.com
More informationEarlier Lecture. In the earlier lecture, we have seen Kapitza & Heylandt systems which are the modifications of the Claude System.
17 1 Earlier Lecture In the earlier lecture, we have seen Kapitza & Heylandt systems which are the modifications of the Claude System. Collins system is an extension of the Claude system to reach lower
More informationCryogenics The Basics. Lesson 2 D. Kashy
Cryogenics The Basics Lesson 2 D. Kashy Lecture 1 Review Lesson 1 - Objectives Looked at common liquids and gases to get a feeling for their properties Looked at Nitrogen and Helium Discussed Pressure
More informationInert Air (N2) Systems Manual
INSTRUCTION MANUAL Inert Air (N2) Systems Manual N2-MANUAL 2.10 READ AND UNDERSTAND THIS MANUAL PRIOR TO OPERATING OR SERVICING THIS PRODUCT. GENERAL INFORMATION Positive pressure nitrogen gas pressurizing
More informationSomnoSuite FAQ. Setup. Calibration 4. What are the calibration requirements for the SomnoSuite? Settings
SomnoSuite FAQ V1.3 January 2015 Setup 1. How do I connect the SomnoSuite to my oxygen source? 2. Is there a way to speed up the downward movement of the pusher block when setting the empty position? 3.
More informationCS Controlled Dissolved Gas assembly with optional CS Air Aspirator assembly. Installation and Operation information
CS-425-01 Controlled Dissolved Gas assembly with optional CS-603-01 Air Aspirator assembly Installation and Operation information Serial # CS-XXX Date of shipment:, 2005 Shipped to: Purchase order #: xxxxxxx
More informationAPPS-160 Gen 2 User Manual
APPS-160 Gen 2 User Manual Applicable Products: PN 11914406 - APPS-160 10 to 50 PSIG operating pressure PN 11918618 - APPS-160 40 to 85 PSIG operating pressure Rev 9/16/2004 Chart Ind. www-chart-ind.com
More information