ACCU-PULSE I Pulsation Dampeners

Size: px
Start display at page:

Download "ACCU-PULSE I Pulsation Dampeners"

Transcription

1 ACCU-PULSE I Pulsation Dampeners Chargeable / Metal / Dome Top FEATURES CRN is available on certain metallic units extensive range of materials lightweight, compact design Technical Data remove pulsating flows from positive displacement pumps increase system efficiency and pump life decrease maintenance and costs protect pipes, meters, instruments, valves, gaskets and seals from pulsation and vibration ensure meter accuracy, longevity and repeatability reduce pressure fluctuations and diaphragm wear prevent foaming and splashing 300 psi rating easy in-line maintenance 2 year warranty Unit Capacity: 10 CU In Weight: 3 pounds Air Control: Gas Fill Valve Inlet Port: 3/8" NPTF, optional 1/2" NPTF Pressure Limit: 300 psi at 70 F ** Shell Materials: 316L Stainless Steel, Carbon Steel, Alloy 20, Hastelloy C Elastomers: Neoprene, Buna-N, EPDM, Viton, Hypalon, Teflon (150 max psi) **Caution: Temperature and pressure affect the strength and chemical resistance of plastic and rubber. PRIMARY FLUID Call Toll Free Tel (905) Fax (905) primary@primary fluid.com

2 ACCU-PULSE I Pulsation Dampeners Operation: ACCU-Pulse pulsation dampeners operate on the principal that volume is inversely proportional to pressure. Compressed air or gas is introduced into the top section of ACCU-Pulse to a specified pressure that must be lower than the pump's discharge pressure. When a pump or valve introduces a pulse, fluid enters the dampener and compresses the trapped gas. The fluid remains in the dampener until the system pressure returns to normal, when the valve is reopened or the pump begins its next cycle. The fluid is then pushed back into the system piping as the trapped gas expands. ACCU-Pulse does NOT restrict fluid flow, or increase system pressure. ACCU-Pulse fills the fluid voids and pressure fluctuations created by reciprocating pumps. Typical Installations: Dimensions: Parts Description: Item Part # Qty Description Material ^ 1 Wetted Housing 316 Stainless Steel ^ Wetted Housing Alloy ^ Wetted Housing Hastelloy C Bladder Neoprene Bladder EPDM Bladder Buna-N Bladder Hypalon Bladder Viton Bladder Aflas P Bladder Teflon 3A NonWetted Housing 316 Stainless Steel P NonWetted Housing Alloy 20 K NonWetted Housing Hastelloy C Fastener Assembly Stainless Steel T Chargeable Air Assembly Plastic, Brass, S/S ^ add suffix -0 for units with 3/8" connections ^ add suffix -1 for units with 1/2" connections Recommended Spare Parts Distributed by: PRIMARY FLUID Call Toll Free WA SA & NT VIC & TAS NSW & ACT Tel: QLD (905) (08) (08) (03) (02) Fax: (07) (905) hydramet@hydramet.com.au hydrasa@hydramet.com.au hydravic@hydramet.com.au hydransw@hydramet.com.au hydraqld@hydramet.com.au E:Mail: primary@primaryfluid.com Registered Trade Mark of Primary Fluid Systems Distribution Territories Available e 2

3 ACCU-PULSE II Pulsation Dampeners Chargeable / Metal / Dome Top PRIMARY FLUID FEATURES CRN is available on certain metallic units extensive range of materials lightweight, compact design Technical Data Call Toll Free Tel (905) Fax (905) remove pulsating flows from positive displacement pumps increase system efficiency and pump life decrease maintenance and costs protect pipes, meters, instruments, valves, gaskets and seals from pulsation and vibration ensure meter accuracy, longevity and repeatability reduce pressure fluctuations and diaphragm wear prevent foaming and splashing 300 psi rating easy in-line maintenance 2 year warranty Unit Capacity: 85 CU In Weight: pounds Air Control: Gas Fill Valve Inlet Port: 3/4" NPTF, optional 1" NPTF Pressure Limit: 300 psi at 70 F ** Shell Materials: 316L Stainless Steel, Alloy 20, Hastelloy C, Carbon Steel Elastomers: Neoprene, Buna-N, EPDM, Viton, Hypalon, Teflon (max 150 psi) **Caution: Temperature and pressure affect the strength and chemical resistance of plastic and rubber. primary@primary fluid.com

4 ACCU-PULSE II Pulsation Dampeners Operation: ACCU-Pulse pulsation dampeners operate on the principal that volume is inversely proportional to pressure. Compressed air or gas is introduced into the top section of ACCU-Pulse to a specified pressure that must be lower than the pump's discharge pressure. When a pump or valve introduces a pulse, fluid enters the dampener and compresses the trapped gas. The fluid remains in the dampener until the system pressure returns to normal, when the valve is reopened or the pump begins its next cycle. The fluid is then pushed back into the system piping as the trapped gas expands. ACCU-Pulse does NOT restrict fluid flow, or increase system pressure. ACCU-Pulse fills the fluid voids and pressure fluctuations created by reciprocating pumps. Typical Installations: Dimensions: Parts Description: Item Part # Qty Description Material ^ 1 W etted Housing 316 Stainless Steel ^ W etted Housing Alloy ^ W etted Housing Hastelloy C Bladder Neoprene Bladder Buna-N Bladder EPDM Bladder Viton Bladder Hypalon Bladder Aflas Bladder Teflon 3A NonW etted Housing 316 Stainless Steel NonW etted Housing Alloy NonW etted Housing Hastelloy C Gauge ( Teflon Bladders ) Plastic, Brass G40 Gauge ( Rubber Bladders ) S/S / Brass Fill Valve Stainless Steel Fastener Assem bly Stainless Steel Fastener Assem bly Stainless Steel ^ add suffix -2 for unit with 3/4" connections ^ add suffix -3 for units with 1" connections + only used with Teflon Bladders Recom m ended Spare Parts Distributed WA by: SA & NT VIC & TAS PRIMARY FLUID NSW Call & ACT Toll Free QLD (08) (08) (03) 9325 SYSTEMS 3900 INC. (02) Tel: (07) (905) Fax: (905) hydramet@hydramet.com.au hydrasa@hydramet.com.au hydravic@hydramet.com.au hydransw@hydramet.com.au hydraqld@hydramet.com.au Registered Trade Mark of Primary Fluid Systems Distribution Territories Available E:Mail: primary@primaryfluid.com e 2

5 ACCU-PULSE III Pulsation Dampeners Chargeable / Metal / Dome Top PRIMARY FLUID FEATURES CRN is available on certain metallic units extensive range of materials lightweight, compact design Technical Data Call Toll Free Tel (905) Fax (905) remove pulsating flows from positive displacement pumps increase system efficiency and pump life decrease maintenance and costs protect pipes, meters, instruments, valves, gaskets and seals from pulsation and vibration ensure meter accuracy, longevity and repeatability reduce pressure fluctations and diaphragm wear prevent foaming and splashing 300 psi rating easy in-line maintenance 2 year warranty Unit Capacity: 370 CU In Weight: pounds Air Control: Gas Fill Valve Inlet Port: 2 NPTF Pressure Limit: 300 psi at 70 F ** (optional F add suffix -H) Shell Materials: 316L Stainless Steel, Alloy 20, Hastelloy C, Carbon S teel Elastomers: Neoprene, Buna-N, EPDM, V iton, Hypalon, Teflon (max 150 p si) **Caution: Temperature and pressure affect the strength and chemical resistance of plastic and rubber. primary@primary fluid.com

6 ACCU-PULSE III Pulsation Dampeners Operation: ACCU-Pulse pulsation dampeners operate on the principal that volume is inversely proportional to pressure. Compressed air or gas is introduced into the top section of ACCU-Pulse to a specified pressure that must be lower than the pump's discharge pressure. When a pump or valve introduces a pulse, fluid enters the dampener and compresses the trapped gas. The fluid remains in the dampener until the system pressure returns to normal, when the valve is reopened or the pump begins its next cycle. The fluid is then pushed back into the system piping as the trapped gas expands. ACCU-Pulse does NOT restrict fluid flow, or increase system pressure. ACCU-Pulse fills the fluid voids and pressure fluctuations created by reciprocating pumps. Typical Installations: Dimensions: Parts Description: Item Part # Qty Description Material Wetted Housing Stainless Steel Wetted Housing Alloy Wetted Housing Hastelloy C Bladder Neoprene Bladder EPDM Bladder Buna - N Bladder Hypalon Bladder Viton Bladder Aflas Bladder Teflon 3A NonWetted Housing 316 Stainless Steel Gauge ( Teflon Bladders ) Plastic / Brass G40 Gauge ( Rubber Bladders ) S/S / Brass Fill Valve Stainless Steel Fastener Assembly Stainless Steel Recommended Spare Parts Distributed by: PRIMARY FLUID Call Toll Free WA SA & NT VIC & TAS NSW & ACT QLD Tel: (905) (08) (08) (03) (02) (07) Fax: 3802 (905) hydramet@hydramet.com.au hydrasa@hydramet.com.au hydravic@hydramet.com.au hydransw@hydramet.com.au hydraqld@hydramet.com.au E:Mail: primary@primaryfluid.com Distribution Territories Available Registered Trade Mark of Primary Fluid Systems e 23

FEATURES. **Caution: Temperature and pressure affect the strength and chemical resistance of plastic and rubber.

FEATURES. **Caution: Temperature and pressure affect the strength and chemical resistance of plastic and rubber. ACCU-PULSE I Pulsation Dampeners Chargeable / Plastic / Dome Top lightweight, compact design 150 psi rating extensive range of materials Technical Data FEATURES remove pulsating flows from positive displacement

More information

PULSATION DAMPENER / SUPPRESSOR SERIES PDS PROVIDES MULTIPLE SYSTEM SAFEGUARDS

PULSATION DAMPENER / SUPPRESSOR SERIES PDS PROVIDES MULTIPLE SYSTEM SAFEGUARDS PULSATION / SUPPRESSOR SERIES PDS PROVIDES MULTIPLE SYSTEM SAFEGUARDS FUNCTIONS: 1. Pulsation Dampener smooths pump flow 2. Surge Suppressor absorbs shocks and vibrations 3. Water Hammer Arrestor eliminates

More information

ACCU-PULSE Installation and Operation Instructions

ACCU-PULSE Installation and Operation Instructions ACCU-PULSE Installation and Operation Instructions Pump Discharge Installation: Chargeable Models Step 1: Mounting Position Mount ACCU-PULSE as close to the pump discharge as possible to absorb the pulse

More information

Model PRS-07i. Stainless Steel Low Pressure, In-Line Pressure Regulator (Reducing Valve)

Model PRS-07i. Stainless Steel Low Pressure, In-Line Pressure Regulator (Reducing Valve) Phone (toll-free): (888) 380-9660 Phone (local): (973) 340-9955 Fax: (973) 340-9933 Web: www.straval.com 21 Columbus Avenue Garfield, NJ 07026 Model PRS-07i Stainless Steel Low Pressure, In-Line Pressure

More information

TOP VALVE. Pat. #5,857,486 & 5,944,050. Mid-Range Pressure PSIG Back Pressure and Pressure Relief Valves. Instruction Manual

TOP VALVE. Pat. #5,857,486 & 5,944,050. Mid-Range Pressure PSIG Back Pressure and Pressure Relief Valves. Instruction Manual TOP VALVE Pat. #5,857,486 & 5,944,050 Mid-Range Pressure 50 232 PSIG Back Pressure and Pressure Relief Valves Instruction Manual Please Note: This instruction manual provides detailed information and instructions

More information

1200 Series Pressure Regulators

1200 Series Pressure Regulators SEE MORE AT SORInc.com Request Quote 1200 Series Pressure SOR pressure regulators are durable, high performing instruments that are designed to provide reliable control of pressure in various stages of

More information

TOP VALVE. Pat. #5,857,486 & 5,944,050. High Temperature: max. 300 F (149 C) Back Pressure And Pressure Relief Valves. Instruction Manual

TOP VALVE. Pat. #5,857,486 & 5,944,050. High Temperature: max. 300 F (149 C) Back Pressure And Pressure Relief Valves. Instruction Manual TOP VALVE Pat. #5,857,486 & 5,944,050 High Temperature: max. 300 F (149 C) Back Pressure And Pressure Relief Valves Instruction Manual PLEASE NOTE: This instruction manual provides information and instructions

More information

OPERATING INSTRUCTIONS MANUAL FOR QACV PNEUMATIC DOSING PUMP

OPERATING INSTRUCTIONS MANUAL FOR QACV PNEUMATIC DOSING PUMP This operating instructions contains safety information that if ignored can endanger life or result in serious injury. They are indicated by this icon. Use of this pump with radioactive chemicals is forbidden!

More information

Foreign language versions available online at:

Foreign language versions available online at: INSTALLATION & OPERATION MANUAL INLET STABILIZER DAMPENER ( J MODEL) SENTRY dampeners are pressure vessels containing a flexible bladder or bellows inside that separates an inert pressurized gas (air or

More information

Cash Valve. Type G-4. Pilot Operated Pressure Reducing Regulator for Steam, Air and Gases. Flow Control

Cash Valve. Type G-4. Pilot Operated Pressure Reducing Regulator for Steam, Air and Gases. Flow Control Cash Valve Type G-4 Pilot Operated Pressure Reducing Regulator for Steam, Air and Gases Issued - March 2001 CAVMC-0512-US-0609 ISO 9001 Certified Flow Control Description FIG 2042 - Bronze FIG 2043 - Bronze

More information

Cash Valve TYPE G-4 PILOT OPERATED PRESSURE REDUCING REGULATOR FOR STEAM, AIR AND GASES. ISSUED - MARCH 2001 CAVMC-0512-US-0208 ISO 9001 Certified

Cash Valve TYPE G-4 PILOT OPERATED PRESSURE REDUCING REGULATOR FOR STEAM, AIR AND GASES. ISSUED - MARCH 2001 CAVMC-0512-US-0208 ISO 9001 Certified Cash Valve TYPE G-4 PILOT OPERATED PRESSURE REDUCING REGULATOR FOR STEAM, AIR AND GASES ISSUED - MARCH 2001 CAVMC-0512-US-0208 ISO 9001 Certified TYPE G-4 DESCRIPTION FIG 2042 - Bronze FIG 2043 - Bronze

More information

DataSheet. Series AA Electronic Metering Pumps. Configuration Data. Dimensions. Specifications. Model AA HI. ISO 9001 Certified

DataSheet. Series AA Electronic Metering Pumps. Configuration Data. Dimensions. Specifications. Model AA HI. ISO 9001 Certified DataSheet Series AA Electronic Metering Pumps Configuration Data Model AA 9 4 1-358HI Control Code 1 --- Manual Control: Speed (stroking frequency) and stroke length manually adjustable. 7 --- Instrument

More information

Precision and Instrument Regulators 1/4" port size

Precision and Instrument Regulators 1/4 port size Section 8 Precision and Instrument Regulators /" port size Contents -8 Precision Air Pressure Regulator /" ports............ale-8-2 R38 Instrument Regulator Aluminum Model /" ports.........ale-8- -8 R38

More information

Installation and Operation Manual Chargeable Dampener Models

Installation and Operation Manual Chargeable Dampener Models Installation and Operation Manual Chargeable Dampener Models SENTRY dampeners are pressure vessels containing a flexible bladder or bellows inside that separates an inert pressurized gas (air or Nitrogen)

More information

OPERATION MANUAL. ALUMINUM Models 316 S.S. Models AIR-OPERATED DOUBLE DIAPHRAGM PUMPS

OPERATION MANUAL. ALUMINUM Models 316 S.S. Models AIR-OPERATED DOUBLE DIAPHRAGM PUMPS OPERATION MANUAL 2 METALLIC PUMP (BOLTED) PWR-FLO TM AIR DISTRIBUTION SYSTEM NPF50 AIR-OPERATED DOUBLE DIAPHRAGM PUMPS ALUMINUM Models 316 S.S. Models A JDA Global Company CAUTIONS - READ FIRST CAUTION:

More information

Installation and Operation Manual

Installation and Operation Manual Installation and Operation Manual Chargeable Dampener Models SENTRY dampeners are pressure vessels containing a flexible bladder or bellows inside that separates an inert pressurized gas (air or Nitrogen)

More information

Air Operated Hydraulic Pumping Systems to 50,000 psi

Air Operated Hydraulic Pumping Systems to 50,000 psi High Pressure Equipment Air Operated Hydraulic Pumping Systems to 50,000 psi PS-10: 10,000 psi PS-20: 20,000 psi PS-30: 30,000 psi PS-40: 40,000 psi PS-50: 50,000 psi PS-90: 90,000 psi High Pressure air

More information

Booster Regulator/Air Tank

Booster Regulator/Air Tank Booster Regulator/Air Tank Increase factory air pressure by up to 4 times! Air-only operation requires no power supply, reduces heat generation, and Boost pressure allows easy installation. NEW Renewed

More information

tel: fax: web:

tel: fax: web: Tri-Flex 2 Five-Cell Permeability Test System For high volume commercial laboratory testing, the Tri-Flex 2 Five-Cell Permeability Test System offers the user the capabilities to test up to five samples

More information

P400/PX400. Advanced Series METAL Pumps. Advance your process. Engineering Operation & Maintenance WIL E-07 REPLACES WIL E-06

P400/PX400. Advanced Series METAL Pumps. Advance your process. Engineering Operation & Maintenance WIL E-07 REPLACES WIL E-06 P400/PX400 Advanced Series METAL Pumps Engineering Operation & Maintenance Advance your process WIL-11210-E-07 REPLACES WIL-11210-E-06 TABLE OF CONTENTS SECTION 1 CAUTIONS READ FIRST!..............................................1

More information

FILTER TYPE PRESSURE SNUBBER

FILTER TYPE PRESSURE SNUBBER FILTER TYPE PRESSURE SNUBBER Pressure oscillations and other sudden pressure changes can affect the delicate mechanisms of a pressure gauge or pressure transmitter. This can result in either complete failure

More information

INDUSTRIAL TRANSFER PUMPS

INDUSTRIAL TRANSFER PUMPS INDUSTRIAL TRANSFER PUMPS Diaphragm Transfer Pumps - Plastic Body Pumps - Metal Body Pumps - Hygienic Pumps - High Pressure Pumps - Powder Pumps PLASTIC BODY PUMPS Diaphragm pumps also run trouble-free

More information

Best Practices for Installation of Gaseous Sample Pumps

Best Practices for Installation of Gaseous Sample Pumps Best Practices for Installation of Gaseous Sample Pumps Goal of the Gas Sample Pump Transport a clean, reliable, sample of the process gas to the analyzer, in the safest and easiest way possible, to ensure

More information

RESIDENTIAL - IRRIGATION - WATER TREATMENT OF FLORIDA PUMP PROTECTION - EFFICIENCY - ENERGY SAVER - COMFORT

RESIDENTIAL - IRRIGATION - WATER TREATMENT OF FLORIDA PUMP PROTECTION - EFFICIENCY - ENERGY SAVER - COMFORT OF FLORIDA Pressure Gauge Dry Pressure gauge DRY Steel casing Lower mount PG060L20D4M 1/4" LOWER MOUNT METAL 2" 0-60 PSI 100 0.21 PG100L20D4M 1/4" LOWER MOUNT METAL 2" 0-100 PSI 100 0.21 Pressure gauge

More information

PILOT OPERATED PRESSURE VACUUM RELIEF VALVE MODEL 1660

PILOT OPERATED PRESSURE VACUUM RELIEF VALVE MODEL 1660 PILOT OPERATED PRESSURE VACUUM RELIEF VALVE MODEL 1660 Patent Protected Premium Seat Tightness to Set Pressure Snap or Modulating Valve Action Provides Ability to Meet Clean Air Act Requirements 600 TYPICAL

More information

PRO-50 Instrument Supply Regulator

PRO-50 Instrument Supply Regulator Features CRN Approved The PRO-50 Regulator has been granted a Canadian Registration Number. Sour Service Capability Available in NACE configurations that comply with NACE MR0175/MR0103. Environmental limits

More information

INSTALLATION & OPERATION MANUAL

INSTALLATION & OPERATION MANUAL INSTALLATION & OPERATION MANUAL DAMPENER (XPX HIGH PRESSURE MODEL) SENTRY dampeners are pressure vessels containing a flexible bladder or bellows inside that separates an inert pressurized gas (air or

More information

FAST & FLEXIBLE EXPERTISE 100% ORDER FULFILLMENT LOW COST PROVIDER

FAST & FLEXIBLE EXPERTISE 100% ORDER FULFILLMENT LOW COST PROVIDER FAST & FLEXIBLE JDA Global LLC (EST. 0) serves as the world s largest & most experienced after-market diaphragm pump products provider. We leverage our deeply embedded industry knowledge each day to bring

More information

Pressure Reducing Valves Pressure Reducing with. Broady Flow Control. D Series Range. Pressure Reducing Valves. Broady Flow Control

Pressure Reducing Valves Pressure Reducing with. Broady Flow Control. D Series Range. Pressure Reducing Valves. Broady Flow Control Pressure Reducing Valves 00 Pressure Reducing with Broady Flow Control D Series Range Pressure Reducing Valves Broady Flow Control The Company Broady Flow Control is an Independent Valve Manufacturer,

More information

The Shand & Jurs Model Vapor Guard Tank Blanketing Valve

The Shand & Jurs Model Vapor Guard Tank Blanketing Valve Lower maintenance due to fewer parts Occupies less space, less stress to tank Teflon is inert to most chemicals; extends service life Simplifies and lowers maintenance cost Optimizes flow of blanketing

More information

SG3 Series Regulators - Pressure Reducing

SG3 Series Regulators - Pressure Reducing SG3 Series Regulators - Pressure Reducing DSG333X1 Specifications For questions about this product, please consult TESCOM. OPERATING PARAMETERS Pressure rating per criteria of CGA E-4; ASME B31; ASME BPVC

More information

Brooks Flow Controllers for Gas and Liquid Service Model FC 8744, Series FC 8800 and FC 8900

Brooks Flow Controllers for Gas and Liquid Service Model FC 8744, Series FC 8800 and FC 8900 Data Sheet Flow Controllers for Gas and Liquid Service Brooks Flow Controllers for Gas and Liquid Service Model FC 8744, Series FC 8800 and FC 8900 Features and Benefits Flow controllers for high pressure

More information

VACUUM REGULATORS CONTENTS

VACUUM REGULATORS CONTENTS CAD drawing data catalog is available. ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS CONTENTS Small Regulators Features 759 Specifications, Order Codes, Flow Rate

More information

Petro-Chemical & Analyzer Sampling Systems

Petro-Chemical & Analyzer Sampling Systems Petro-Chemical & Analyzer Sampling Systems Pressure control solutions for your industry. The Tescom brand offers a comprehensive range of regulators, valves and changeover systems that are ideal for analyzer

More information

Petro-Chemical & Analyzer Sampling Systems

Petro-Chemical & Analyzer Sampling Systems Petro-Chemical & Analyzer Sampling Systems Pressure control solutions for your industry. The Tescom brand offers a comprehensive range of regulators, valves and changeover systems that are ideal for analyzer

More information

HAYWARD FLOW CONTROL Series PBV Back Pressure Valve and Series RPV Pressure Relief Valve INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS

HAYWARD FLOW CONTROL Series PBV Back Pressure Valve and Series RPV Pressure Relief Valve INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS HAYWARD FLOW CONTROL Series PBV Back Pressure Valve and Series RPV Pressure Relief Valve INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS Page 1 of 20 Page 2 of 20 TABLE OF CONTENTS Safety Warnings

More information

OPERATOR S MANUAL

OPERATOR S MANUAL OPERATOR S MANUAL 1604619 INCLUDING: OPERATION, INSTALLATION & MAINTENANCE RELEASED: 11-1-13 REVISED: 3-03-14 (REV. B) 1/4" DIAPHRAGM PUMP 1:1 RATIO (NON-METALLIC) 1604628 READ THIS MANUAL CAREFULLY BEFORE

More information

P800/PX800. Advanced Series METAL Pumps. Advance your process. Engineering Operation & Maintenance WIL E-12 REPLACES WIL E-11

P800/PX800. Advanced Series METAL Pumps. Advance your process. Engineering Operation & Maintenance WIL E-12 REPLACES WIL E-11 P800/PX800 Advanced Series METAL Pumps Engineering Operation & Maintenance Advance your process WIL-11220-E-12 REPLACES WIL-11220-E-11 TABLE OF CONTENTS SECTION 1 CAUTIONS READ FIRST!..............................................1

More information

The "BETA AIR RELAY"

The BETA AIR RELAY SP251.C 1/9 The "BETA AIR RELAY" The pressure operated AIR RELAY Specially designed for: Valve Control Offshore & Onshore Zone 0 applications Products and specifications are liable to be changed without

More information

FLOAT OPERATED LEVEL CONTROLLER

FLOAT OPERATED LEVEL CONTROLLER PNEUMATIC LEVEL SWITCH APPLICATION: Liquid level controller for oil and gas separators, water knockouts, gas scrubbers and accumulators. FEATURES: Rated for 2000 psi working pressure Push-button dump valve

More information

Need the part number for an impeller, seal, gasket, or motor? It s all here.

Need the part number for an impeller, seal, gasket, or motor? It s all here. Check here for parts questions Flexible Impeller Reference Guide Service Parts & Kits Service & Warranty Information 92 Need the part number for an impeller, seal, gasket, or motor? It s all here. Highlights:

More information

Cash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified

Cash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified Cash Valve PILOT OPERATED BACK PRESSURE VALVE ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 01 Certified KP HIGH CAPACITY PILOT OPERATED BACK PRESSURE VALVE DESCRIPTION The Cash Valve Type KP is a pilot

More information

Direct Operated Precision Regulator Modular Style. Standard Specifications

Direct Operated Precision Regulator Modular Style. Standard Specifications 1 Direct Operated Precision Regulator Modular Style Series P3 Courtesy of Steven Engineering, Inc.-23 Ryan Way, South San Francisco, CA 948-637-Main Office: (65) 588-92-Outside Local Area: (8) 258-92-www.stevenengineering.com

More information

EOM PX1500. Engineering Operation & Maintenance. Advanced Series Metal Pump. WIL E-10 Replaces WIL E-09

EOM PX1500. Engineering Operation & Maintenance. Advanced Series Metal Pump.  WIL E-10 Replaces WIL E-09 EOM Engineering Operation & Maintenance PX1500 Advanced Series Metal Pump W h e r e I n n o v a t i o n F l o w s. www.wildenpump.com WIL-11230-E-10 Replaces WIL-11230-E-09 TABLE OF CONTENTS SECTION 1

More information

A050-1/2 INCH AIR OPERATED double DIAPHRAGM PUMP

A050-1/2 INCH AIR OPERATED double DIAPHRAGM PUMP A050 - /2 INCH AIR OPERATED double DIAPHRAGM PUMP A050 /2 Pump /2 Aluminum NPT or BSP Connections Zinc Plated Hardware Non-Metallic Muffler Suction Right / Discharge Right Standard Porting SPECIFICATIONS

More information

FLOAT OPERATED LEVEL CONTROLLER

FLOAT OPERATED LEVEL CONTROLLER PNEUMATIC LEVEL SWITCH NO RELAY APPLICATION: Liquid level controller for oil and gas separators, water knockouts, gas scrubbers and accumulators. FEATURES: Push-button dump valve override standard Float

More information

P400/PX400. Advanced Series METAL Pumps. Advance your process. Engineering Operation & Maintenance WIL E-12 REPLACES WIL E-11

P400/PX400. Advanced Series METAL Pumps. Advance your process. Engineering Operation & Maintenance WIL E-12 REPLACES WIL E-11 P400/PX400 Advanced Series METAL Pumps Engineering Operation & Maintenance Advance your process WIL-11210-E-12 REPLACES WIL-11210-E-11 TABLE OF CONTENTS SECTION 1 CAUTIONS READ FIRST!..............................................1

More information

Model 4000 Pressure Controller

Model 4000 Pressure Controller FEATURES Multiple Configurations The 4000 series pressure controller can be configured into either proportional only or proportional plus reset mode with a minimum of parts. Rugged Design Die cast aluminum

More information

Mark 630 Series. High Pressure Regulators Mark 630 High Pressure Regulators. High Pressure Regulators. Features

Mark 630 Series. High Pressure Regulators Mark 630 High Pressure Regulators. High Pressure Regulators. Features Mark 630 Series High Pressure Regulators The Jordan Mark 630 self-operated pressure reducing regulator is designed to provide tight shutoff and accurate regulation on high pressure gas systems. It can

More information

WHITE PAPER Overview of Diaphragm and Chemical Seals

WHITE PAPER Overview of Diaphragm and Chemical Seals WHITE PAPER Overview of Diaphragm and Chemical Seals WHITE PAPER Overview of Diaphragm and Chemical Seals Introduction A diaphragm or chemical seal is a device comprised of a thin membrane known as a diaphragm,

More information

SG1 Series Regulators - Pressure Reducing

SG1 Series Regulators - Pressure Reducing SG1 Series Regulators - Pressure Reducing DSG131X Specifications For questions about this product, please consult TESCOM. OPERATING PARAMETERS Pressure rating per criteria of CGA E-; ASME B31; ASME BPVC

More information

Product Data Screwed Valves

Product Data Screwed Valves Screwed Valves Brass and Chrome PVC Stainless Steel Flow Control Check Valves - 15mm Flow Control Check Valves - 25mm AUSTRALIA Maric Brass & Chrome Screwed Valves p. 28 Availability & Specifications Maric

More information

Liquid ring vacuum pumps in compact design

Liquid ring vacuum pumps in compact design Liquid ring vacuum pumps in compact design, Pressure range: Suction volume flow: 33 to 113 mbar 3 to 58 m³/h CONSTRUCTION TYPE SIHI liquid ring vacuum pumps are displacement pumps of uncomplicated and

More information

Technical Process Bulletin

Technical Process Bulletin Technical Process Bulletin RIDOLINE 53 Alkaline Immersion Cleaner 1. Introduction: Technical Process Bulletin No. 234242 This Revision: 23-11-1990 RIDOLINE 53 is a powdered, silicated, alkaline immersion

More information

Choosing the right miniature instrument and control valve is a snap

Choosing the right miniature instrument and control valve is a snap Choosing the right miniature instrument and control valve is a snap INVALCO Micro Valve The Micro Valve is a unique miniature valve offering versatility and rugged construction. Since its introduction

More information

ALE-40. R06 Miniature Brass Body Regulator. Water and Compressed Air Service 1/8" and 1/4" PTF Port Sizes. Air line equipment.

ALE-40. R06 Miniature Brass Body Regulator. Water and Compressed Air Service 1/8 and 1/4 PTF Port Sizes. Air line equipment. Air line equipment R Miniature Brass Body Regulator Water and Compressed Air Service 1/" and 1/" PTF Port Sizes Compact design, corrosion resistant construction Brass body with choice of plastic or brass

More information

FloWash. Industrial Filter Cart

FloWash. Industrial Filter Cart OPERATION AND MAINTENANCE MANUAL FloWash Industrial Filter Cart Read all instructions before installation or operation of equipment. Failure to comply with these instructions could result in bodily injury

More information

RK-IR Sample Draw Aspirator Adapter Operator s Manual

RK-IR Sample Draw Aspirator Adapter Operator s Manual 30-0951RK-IR Sample Draw Aspirator Adapter Operator s Manual Part Number: 71-0018RK Revision: A Released: 6/2/10 www.rkiinstruments.com Product Warranty RKI Instruments, Inc. warrants gas alarm equipment

More information

Diaphragm Accumulators

Diaphragm Accumulators Diaphragm Accumulators HYDAC Diaphragm Accumulators Index Page 1. Description 3 Introduction 3 Construction 3 2. Applications 4 3. Technical Data 6 Operation 6 Technical Specifications 6 Temperature Effect

More information

DEPA Air Operated Diaphragm Pumps

DEPA Air Operated Diaphragm Pumps DEPA Air Operated Diaphragm Pumps Series M Type DL Cast Metal Pumps DEPA air operated diaphragm pumps made of cast metal are the best suitable solution for most industrial applications. Many years experience

More information

CSA Sample Draw Aspirator Adapter Operator s Manual

CSA Sample Draw Aspirator Adapter Operator s Manual 30-0951-CSA Sample Draw Aspirator Adapter Operator s Manual Part Number: 71-0367 Revision: 0 Released: 4/30/15 www.rkiinstruments.com WARNING Read and understand this instruction manual before operating

More information

PRESSURE & TEMPERATURE GAUGES PRESSURE TEMPERATURE. Catalogue H20200a

PRESSURE & TEMPERATURE GAUGES PRESSURE TEMPERATURE. Catalogue H20200a PRESSURE & TEMPERATURE GAUGES PRESSURE Catalogue TEMPERATURE Applications The label Trafag Industrial Components extends the Trafag brand name to instruments manufactured by qualified partner companies.

More information

RK LEL Sample Draw Aspirator Adapter Operator s Manual

RK LEL Sample Draw Aspirator Adapter Operator s Manual 30-0951RK LEL Sample Draw Aspirator Adapter Operator s Manual Part Number: 71-0017RK Revision: A Released: 6/2/10 www.rkiinstruments.com Product Warranty RKI Instruments, Inc. warrants gas alarm equipment

More information

R133 HELYON. Brass high pressure regulator, suitable for compressed air, gas and liquid

R133 HELYON. Brass high pressure regulator, suitable for compressed air, gas and liquid R133 Brass high pressure regulator, suitable for compressed air, gas and liquid HELYON 5 Chemin du Jubin 6957 DARDILLY Tél. +33 () 7 5 16 7 - Fax +33 () 7 5 16 71 FEATURES High pressure regulator for cylinder

More information

TECHNICAL DATA. Page 1 of 12

TECHNICAL DATA. Page 1 of 12 Page 1 of 12 1. DESCRIPTION The Viking Regulating Valve is a direct-acting, single-seated, spring-loaded diaphragm valve. When installed as a pilot regulating valve on a Viking Model H or J Flow Control

More information

SG2 Series Regulators - Pressure Reducing

SG2 Series Regulators - Pressure Reducing SG2 Series Regulators - Pressure Reducing DSG2232X Specifications For questions about this product, please consult TESCOM. OPERATING PARAMETERS Pressure rating per criteria of CGA E-; ASME B31; ASME BPVC

More information

ANDERSON GREENWOOD SERIES 9000 POSRV INSTALLATION AND MAINTENANCE INSTRUCTIONS

ANDERSON GREENWOOD SERIES 9000 POSRV INSTALLATION AND MAINTENANCE INSTRUCTIONS Procedure-assembly-functional test and performance requirements 1 SCOPE 1.1 This document establishes the general procedure for assembly, functional testing and normal performance requirements of low Series

More information

FOAM TANK (1/2) DATA SHEET

FOAM TANK (1/2) DATA SHEET FIRE FIGHTING EQUIPMENT DATA SHEET FOAM TANK (1/) DATA SHEET JOB NO. : RFQ. NO. : ISSUE : SHEET OF 01 CUSTOMER : ITEM NO. : 0 PROJECT : QUANTITY : 0 LOCATION : SERVICE : FOAM SYSTEM 0 05 CODE & STANDARDS

More information

Pneumatic Powered - Plunger Pumps

Pneumatic Powered - Plunger Pumps Models 42/62/82 D Series P.O. Box 80769 Lafayette, LA 70598-0769 (337) 235-9838 FAX (337) 235-9852 www.sidewinderpumps.com Pneumatic Powered - Plunger Pumps Suggested Installation & Operating Instructions

More information

Diaphragm Accumulators

Diaphragm Accumulators Diaphragm Accumulators. DESCRIPTION.. FNCTION Fluids are practically incompressible and cannot therefore store pressure energy. The compressibility of a gas is utilised in HYDAC diaphragm accumulators

More information

Application and Sizing

Application and Sizing Application and Sizing Energy accumulator: It is improbable that an hydraulic system use all of its capacity without interruptions. An hydropneumatic accumulator can store a certain amount of fluid that

More information

SABERINDO PACIF SABERINDO PACIFIC CIFIC SABERINDO PA. A Tyco International Company

SABERINDO PACIF SABERINDO PACIFIC CIFIC SABERINDO PA. A Tyco International Company CIF A Tyco International Company 1 Foam Concentrate CIF 3% AFFF -UL Listed -UL Canada Listed 6% AFFF 6 parts AFFF concentrate to 94 parts water -UL Listed- Foam Liquid -UL Canada Listed 3% FLUOROPROTEIN

More information

Impeller Replacement -

Impeller Replacement - 10 www.jabsco.com Introduction Jabsco - The Original Impeller Jabsco flexible impellers can be fitted to most makes and models of bronze flexible impeller engine cooling, bilge, transfer and general purpose

More information

KDV HIGH ACCURACY GLASS TUBE ROTAMETER

KDV HIGH ACCURACY GLASS TUBE ROTAMETER KDV HIGH ACCURACY GLASS TUBE ROTAMETER Flow Pressure Level Temperature measurement monitoring control S2 Industrial and Sanitary Designs Body Sizes 1/2 Through 2 Reliable, Time Proven Glass Tube Design

More information

safety shut-off Valve HON 703 / HON 704

safety shut-off Valve HON 703 / HON 704 safety shut-off Valve HON 703 / HON 704 Product information serving the gas industry worldwide Applications, characteristics, technical data Applications Main safety device in gas pressure regulating systems

More information

OWNER S TECHNICAL MANUAL

OWNER S TECHNICAL MANUAL EL SERIES OWNER S TECHNICAL MANUAL DP7002 1 Air Operated Diaphragm Pump Description The DP7002 1 air operated diaphragm pump is the ideal device for the pumping, transfer and dispensing of chemical liquids,

More information

12 Impeller Replacement

12 Impeller Replacement 144 Impeller Replacement INTRODUCTION Jabsco The Original Impeller Jabsco Flexible Impellers can be fitted to most makes and models of bronze flexible impeller engine cooling, bilge, transfer and general

More information

Wallace & Tiernan Flow Measurement Equipment

Wallace & Tiernan Flow Measurement Equipment Water Technologies Wallace & Tiernan Flow Measurement Equipment Glass Tube Varea-Meter Units Features Rugged, One-Piece Enclosure The welded, deep-formed frame is heavy gauge 302 stainless steel. It protects

More information

Bladder Accumulators. General Information. Bladder Accumulators. Introduction. Accumulator Function. Why use a Bladder Accumulator?

Bladder Accumulators. General Information. Bladder Accumulators. Introduction. Accumulator Function. Why use a Bladder Accumulator? General Information Introduction Accumulator unction Bladder accumulators provide a means of regulating the performance of a hydraulic system. The design of the Stauff bladder accumulator makes use of

More information

Pressure Independent Control Series

Pressure Independent Control Series Document No. 155-522 Pressure Independent Control Series Two-Way Cast Iron Flanged Bodies, ANSI 125 and 250 Description Siemens Pressure Independent Control Valves integrate three functions into a single

More information

Bladder Accumulators High pressure

Bladder Accumulators High pressure Bladder Accumulators High pressure 1. DESCRIPTION 1.1. FUNCTION Fluids are practically incompressible and cannot therefore store pressure energy. The compressibility of a gas (nitrogen) is utilised in

More information

TECHNICAL DATA. Low-Flow Foam Preaction System with Hydraulically Actuated Concentrate Control Valve.

TECHNICAL DATA. Low-Flow Foam Preaction System with Hydraulically Actuated Concentrate Control Valve. Foam 302 a 1. DESCRIPTION (Refer to Figure 1 on page 302 e.) The Viking Low-Flow Foam/Water Proportioning System is a UL Listed and FM Approved system, for use with 3M and Viking brand foam concentrate.

More information

OPERATION MANUAL AIR-OPERATED DOUBLE DIAPHRAGM PUMPS 1.5 POLYPROPYLENE PUMP PWR-FLO TM AIR DISTRIBUTION SYSTEM NPF40 CLAMPED. A JDA Global Company

OPERATION MANUAL AIR-OPERATED DOUBLE DIAPHRAGM PUMPS 1.5 POLYPROPYLENE PUMP PWR-FLO TM AIR DISTRIBUTION SYSTEM NPF40 CLAMPED. A JDA Global Company OPERATION MANUAL 1.5 POLYPROPYLENE PUMP PWR-FLO TM AIR DISTRIBUTION SYSTEM NPF40 CLAMPED AIR-OPERATED DOUBLE DIAPHRAGM PUMPS A JDA Global Company CAUTIONS - READ FIRST CAUTION: Do not apply compressed

More information

FOAM TANK (1/2) DATA SHEET

FOAM TANK (1/2) DATA SHEET FIRE FIGHTING EQUIPMENT DATA SHEET FOAM TANK (1/2) DATA SHEET JOB NO. : RFQ. NO. : ISSUE : SHEET OF 01 CUSTOMER : ITEM NO. : 02 PROJECT : QUANTITY : 03 LOCATION : SERVICE : FOAM SYSTEM 04 05 CODE & STANDARDS

More information

INSTALLATION AND OPERATING INSTRUCTIONS

INSTALLATION AND OPERATING INSTRUCTIONS INSTALLATION AND OPERATING INSTRUCTIONS For 3D Instruments Direct Drive Pressure Gauges 3D Instruments Inc., 15542 Chemical Lane, Huntington Beach, CA, 92649, U.S.A. Tel. (714) 894-5351, Fax. (714) 895-4309

More information

PX1500. Advanced Series METAL Pumps. Advance your process. Engineering Operation & Maintenance. WIL E-02 Replaces WIL E-01

PX1500. Advanced Series METAL Pumps. Advance your process. Engineering Operation & Maintenance. WIL E-02 Replaces WIL E-01 PX1500 Advanced Series METAL Pumps Engineering Operation & Maintenance Advance your process WIL-11230-E-02 Replaces WIL-11230-E-01 TABLE OF CONTENTS SECTION 1 CAUTIONS READ FIRST!..............................................1

More information

Maximum 0.85 MPa pressure setting Long-life, high flow perfect for balancer applications

Maximum 0.85 MPa pressure setting Long-life, high flow perfect for balancer applications Outstanding performance in extremely low pressure and low pressure ranges from 0.003 to. Realizing high performance, energy saving, and compact size. Realize precise pressure control in a pressure range

More information

SERIES 30. Spring Operated Tank Blanketing Valve PROTECTOSEAL.

SERIES 30. Spring Operated Tank Blanketing Valve PROTECTOSEAL. SERIES 30 PROTECTOSEAL 1 2" NPT inlet and outlet standard Direct acting valve mechanism Optional flanged or threaded inlet and outlet connections available Inlet gas pressures from 10 PSIG to 200 PSIG

More information

Versa-Surge Surge Suppressors for Air-Driven Diaphragm Pumps

Versa-Surge Surge Suppressors for Air-Driven Diaphragm Pumps SER & OPERTG MUL ersa-surge Surge Suppressors for ir-driven Diaphragm Pumps Metallic Construction Table of Contents Product and Operating Principle... Product omenclature Description...2, 3 Materials and

More information

Series IRV1000/2000/3000

Series IRV1000/2000/3000 CAT.ES60-16 A Regulator Series /2000/3000 Allows adjustment of vacuum line pressure Regulator Series /2000/3000 3 sizes offered in the series Variations have been expanded to three sizes from only one

More information

OFI Testing Equipment - Aging Cell Instructions Page 1 of 4. Instructions OFITE AGING CELLS

OFI Testing Equipment - Aging Cell Instructions Page 1 of 4. Instructions OFITE AGING CELLS OFI Testing Equipment - Aging Cell Instructions Page 1 of 4 Instructions OFITE AGING CELLS The OFITE Aging Cell is a patented pressure vessel that enables samples to be subjected to temperatures higher

More information

TECHNICAL DATA. than the water inlet pressure to the concentrate

TECHNICAL DATA. than the water inlet pressure to the concentrate Foam102a 1. DESCRIPTION The Viking Low Flow Foam/Water proportioning system, is a UL Listed and FM Approved system, for use with 3M foam concentrates. This system consists of a standard wet pipe sprinkler

More information

553 Series.

553 Series. 38467.03 www.caleffi.com Pre-adjustable filling units Copyright 01 Caleffi 3 Series Function The automatic filling valve is a device consisting of a pressure reducing valve with compensating seat, visual

More information

Instruction Manual. Standard Surge Eliminator. Standard X. Flushable X - X

Instruction Manual. Standard Surge Eliminator. Standard X. Flushable X - X Standard Surge Eliminator Standard 104052 - X Flushable 104053 - X - X Page 2 of 16 Issue: 2.3 Index Section 1.1 General Description 1.2 Operating Principle 1.3 Specification 1.4 Fitting Selection - Standard

More information

PMI Advanced Automated. Pulse Decay Permeameter APDP-10K-HP-101. Not just products... Solutions!

PMI Advanced Automated. Pulse Decay Permeameter APDP-10K-HP-101. Not just products... Solutions! PMI Advanced Automated Pulse Decay Permeameter APDP-10K-HP-101 Not just products... Solutions! DESCRIPTION The PMI s Advanced automated pulse decay Permeameter is used to measure gas permeability of samples

More information

Test pumps. Pressure sources. Good reasons for proper and reliable calibration

Test pumps. Pressure sources. Good reasons for proper and reliable calibration Test pumps Pressure is one of the most commonly measured quantities in engineering, which is why exact and reliable pressure measurement is especially important. However, the characteristics of the even

More information

Description Advanced Features Typical Applications

Description Advanced Features Typical Applications Series single stage, brass barstock line regulator Description Advanced Features Typical Applications The Series regulators are intended for secondary pressure control of noncorrosive, high purity or liquefied

More information

Total Pressure Regulator Solutions.

Total Pressure Regulator Solutions. Total Pressure Regulator Solutions www.pressure-tech.com Working with customers to support their exact needs A pressure regulator is a critical component in any fluid control system. At Pressure Tech,

More information

MV-Series High-Pressure Valves USER GUIDE

MV-Series High-Pressure Valves USER GUIDE MV-Series High-Pressure Valves USER GUIDE 369 Syringa Ridge Sandpoint, ID 83864 281.782.8312 www.vindum.com support@vindum.com V:1.0 (6-27-17) This page is intentionally blank. Copyright 2017 Vindum Engineering,

More information

Buying more than 11 gauges? Call Lesman for additional discounts.

Buying more than 11 gauges? Call Lesman for additional discounts. Low Cost Liquid Filled Pressure Gauges Size: 1.5", 2", and 2.5" Accuracy: 2.5% of full scale Materials: Case and ring: 304 stainless steel; Window: Polycarbonate; Seals: Buna-N; Pointer: Black-finished

More information