ACCU-PULSE I Pulsation Dampeners
|
|
- Roy Lynch
- 5 years ago
- Views:
Transcription
1 ACCU-PULSE I Pulsation Dampeners Chargeable / Metal / Dome Top FEATURES CRN is available on certain metallic units extensive range of materials lightweight, compact design Technical Data remove pulsating flows from positive displacement pumps increase system efficiency and pump life decrease maintenance and costs protect pipes, meters, instruments, valves, gaskets and seals from pulsation and vibration ensure meter accuracy, longevity and repeatability reduce pressure fluctuations and diaphragm wear prevent foaming and splashing 300 psi rating easy in-line maintenance 2 year warranty Unit Capacity: 10 CU In Weight: 3 pounds Air Control: Gas Fill Valve Inlet Port: 3/8" NPTF, optional 1/2" NPTF Pressure Limit: 300 psi at 70 F ** Shell Materials: 316L Stainless Steel, Carbon Steel, Alloy 20, Hastelloy C Elastomers: Neoprene, Buna-N, EPDM, Viton, Hypalon, Teflon (150 max psi) **Caution: Temperature and pressure affect the strength and chemical resistance of plastic and rubber. PRIMARY FLUID Call Toll Free Tel (905) Fax (905) primary@primary fluid.com
2 ACCU-PULSE I Pulsation Dampeners Operation: ACCU-Pulse pulsation dampeners operate on the principal that volume is inversely proportional to pressure. Compressed air or gas is introduced into the top section of ACCU-Pulse to a specified pressure that must be lower than the pump's discharge pressure. When a pump or valve introduces a pulse, fluid enters the dampener and compresses the trapped gas. The fluid remains in the dampener until the system pressure returns to normal, when the valve is reopened or the pump begins its next cycle. The fluid is then pushed back into the system piping as the trapped gas expands. ACCU-Pulse does NOT restrict fluid flow, or increase system pressure. ACCU-Pulse fills the fluid voids and pressure fluctuations created by reciprocating pumps. Typical Installations: Dimensions: Parts Description: Item Part # Qty Description Material ^ 1 Wetted Housing 316 Stainless Steel ^ Wetted Housing Alloy ^ Wetted Housing Hastelloy C Bladder Neoprene Bladder EPDM Bladder Buna-N Bladder Hypalon Bladder Viton Bladder Aflas P Bladder Teflon 3A NonWetted Housing 316 Stainless Steel P NonWetted Housing Alloy 20 K NonWetted Housing Hastelloy C Fastener Assembly Stainless Steel T Chargeable Air Assembly Plastic, Brass, S/S ^ add suffix -0 for units with 3/8" connections ^ add suffix -1 for units with 1/2" connections Recommended Spare Parts Distributed by: PRIMARY FLUID Call Toll Free WA SA & NT VIC & TAS NSW & ACT Tel: QLD (905) (08) (08) (03) (02) Fax: (07) (905) hydramet@hydramet.com.au hydrasa@hydramet.com.au hydravic@hydramet.com.au hydransw@hydramet.com.au hydraqld@hydramet.com.au E:Mail: primary@primaryfluid.com Registered Trade Mark of Primary Fluid Systems Distribution Territories Available e 2
3 ACCU-PULSE II Pulsation Dampeners Chargeable / Metal / Dome Top PRIMARY FLUID FEATURES CRN is available on certain metallic units extensive range of materials lightweight, compact design Technical Data Call Toll Free Tel (905) Fax (905) remove pulsating flows from positive displacement pumps increase system efficiency and pump life decrease maintenance and costs protect pipes, meters, instruments, valves, gaskets and seals from pulsation and vibration ensure meter accuracy, longevity and repeatability reduce pressure fluctuations and diaphragm wear prevent foaming and splashing 300 psi rating easy in-line maintenance 2 year warranty Unit Capacity: 85 CU In Weight: pounds Air Control: Gas Fill Valve Inlet Port: 3/4" NPTF, optional 1" NPTF Pressure Limit: 300 psi at 70 F ** Shell Materials: 316L Stainless Steel, Alloy 20, Hastelloy C, Carbon Steel Elastomers: Neoprene, Buna-N, EPDM, Viton, Hypalon, Teflon (max 150 psi) **Caution: Temperature and pressure affect the strength and chemical resistance of plastic and rubber. primary@primary fluid.com
4 ACCU-PULSE II Pulsation Dampeners Operation: ACCU-Pulse pulsation dampeners operate on the principal that volume is inversely proportional to pressure. Compressed air or gas is introduced into the top section of ACCU-Pulse to a specified pressure that must be lower than the pump's discharge pressure. When a pump or valve introduces a pulse, fluid enters the dampener and compresses the trapped gas. The fluid remains in the dampener until the system pressure returns to normal, when the valve is reopened or the pump begins its next cycle. The fluid is then pushed back into the system piping as the trapped gas expands. ACCU-Pulse does NOT restrict fluid flow, or increase system pressure. ACCU-Pulse fills the fluid voids and pressure fluctuations created by reciprocating pumps. Typical Installations: Dimensions: Parts Description: Item Part # Qty Description Material ^ 1 W etted Housing 316 Stainless Steel ^ W etted Housing Alloy ^ W etted Housing Hastelloy C Bladder Neoprene Bladder Buna-N Bladder EPDM Bladder Viton Bladder Hypalon Bladder Aflas Bladder Teflon 3A NonW etted Housing 316 Stainless Steel NonW etted Housing Alloy NonW etted Housing Hastelloy C Gauge ( Teflon Bladders ) Plastic, Brass G40 Gauge ( Rubber Bladders ) S/S / Brass Fill Valve Stainless Steel Fastener Assem bly Stainless Steel Fastener Assem bly Stainless Steel ^ add suffix -2 for unit with 3/4" connections ^ add suffix -3 for units with 1" connections + only used with Teflon Bladders Recom m ended Spare Parts Distributed WA by: SA & NT VIC & TAS PRIMARY FLUID NSW Call & ACT Toll Free QLD (08) (08) (03) 9325 SYSTEMS 3900 INC. (02) Tel: (07) (905) Fax: (905) hydramet@hydramet.com.au hydrasa@hydramet.com.au hydravic@hydramet.com.au hydransw@hydramet.com.au hydraqld@hydramet.com.au Registered Trade Mark of Primary Fluid Systems Distribution Territories Available E:Mail: primary@primaryfluid.com e 2
5 ACCU-PULSE III Pulsation Dampeners Chargeable / Metal / Dome Top PRIMARY FLUID FEATURES CRN is available on certain metallic units extensive range of materials lightweight, compact design Technical Data Call Toll Free Tel (905) Fax (905) remove pulsating flows from positive displacement pumps increase system efficiency and pump life decrease maintenance and costs protect pipes, meters, instruments, valves, gaskets and seals from pulsation and vibration ensure meter accuracy, longevity and repeatability reduce pressure fluctations and diaphragm wear prevent foaming and splashing 300 psi rating easy in-line maintenance 2 year warranty Unit Capacity: 370 CU In Weight: pounds Air Control: Gas Fill Valve Inlet Port: 2 NPTF Pressure Limit: 300 psi at 70 F ** (optional F add suffix -H) Shell Materials: 316L Stainless Steel, Alloy 20, Hastelloy C, Carbon S teel Elastomers: Neoprene, Buna-N, EPDM, V iton, Hypalon, Teflon (max 150 p si) **Caution: Temperature and pressure affect the strength and chemical resistance of plastic and rubber. primary@primary fluid.com
6 ACCU-PULSE III Pulsation Dampeners Operation: ACCU-Pulse pulsation dampeners operate on the principal that volume is inversely proportional to pressure. Compressed air or gas is introduced into the top section of ACCU-Pulse to a specified pressure that must be lower than the pump's discharge pressure. When a pump or valve introduces a pulse, fluid enters the dampener and compresses the trapped gas. The fluid remains in the dampener until the system pressure returns to normal, when the valve is reopened or the pump begins its next cycle. The fluid is then pushed back into the system piping as the trapped gas expands. ACCU-Pulse does NOT restrict fluid flow, or increase system pressure. ACCU-Pulse fills the fluid voids and pressure fluctuations created by reciprocating pumps. Typical Installations: Dimensions: Parts Description: Item Part # Qty Description Material Wetted Housing Stainless Steel Wetted Housing Alloy Wetted Housing Hastelloy C Bladder Neoprene Bladder EPDM Bladder Buna - N Bladder Hypalon Bladder Viton Bladder Aflas Bladder Teflon 3A NonWetted Housing 316 Stainless Steel Gauge ( Teflon Bladders ) Plastic / Brass G40 Gauge ( Rubber Bladders ) S/S / Brass Fill Valve Stainless Steel Fastener Assembly Stainless Steel Recommended Spare Parts Distributed by: PRIMARY FLUID Call Toll Free WA SA & NT VIC & TAS NSW & ACT QLD Tel: (905) (08) (08) (03) (02) (07) Fax: 3802 (905) hydramet@hydramet.com.au hydrasa@hydramet.com.au hydravic@hydramet.com.au hydransw@hydramet.com.au hydraqld@hydramet.com.au E:Mail: primary@primaryfluid.com Distribution Territories Available Registered Trade Mark of Primary Fluid Systems e 23
FEATURES. **Caution: Temperature and pressure affect the strength and chemical resistance of plastic and rubber.
ACCU-PULSE I Pulsation Dampeners Chargeable / Plastic / Dome Top lightweight, compact design 150 psi rating extensive range of materials Technical Data FEATURES remove pulsating flows from positive displacement
More informationPULSATION DAMPENER / SUPPRESSOR SERIES PDS PROVIDES MULTIPLE SYSTEM SAFEGUARDS
PULSATION / SUPPRESSOR SERIES PDS PROVIDES MULTIPLE SYSTEM SAFEGUARDS FUNCTIONS: 1. Pulsation Dampener smooths pump flow 2. Surge Suppressor absorbs shocks and vibrations 3. Water Hammer Arrestor eliminates
More informationACCU-PULSE Installation and Operation Instructions
ACCU-PULSE Installation and Operation Instructions Pump Discharge Installation: Chargeable Models Step 1: Mounting Position Mount ACCU-PULSE as close to the pump discharge as possible to absorb the pulse
More informationModel PRS-07i. Stainless Steel Low Pressure, In-Line Pressure Regulator (Reducing Valve)
Phone (toll-free): (888) 380-9660 Phone (local): (973) 340-9955 Fax: (973) 340-9933 Web: www.straval.com 21 Columbus Avenue Garfield, NJ 07026 Model PRS-07i Stainless Steel Low Pressure, In-Line Pressure
More informationTOP VALVE. Pat. #5,857,486 & 5,944,050. Mid-Range Pressure PSIG Back Pressure and Pressure Relief Valves. Instruction Manual
TOP VALVE Pat. #5,857,486 & 5,944,050 Mid-Range Pressure 50 232 PSIG Back Pressure and Pressure Relief Valves Instruction Manual Please Note: This instruction manual provides detailed information and instructions
More information1200 Series Pressure Regulators
SEE MORE AT SORInc.com Request Quote 1200 Series Pressure SOR pressure regulators are durable, high performing instruments that are designed to provide reliable control of pressure in various stages of
More informationTOP VALVE. Pat. #5,857,486 & 5,944,050. High Temperature: max. 300 F (149 C) Back Pressure And Pressure Relief Valves. Instruction Manual
TOP VALVE Pat. #5,857,486 & 5,944,050 High Temperature: max. 300 F (149 C) Back Pressure And Pressure Relief Valves Instruction Manual PLEASE NOTE: This instruction manual provides information and instructions
More informationOPERATING INSTRUCTIONS MANUAL FOR QACV PNEUMATIC DOSING PUMP
This operating instructions contains safety information that if ignored can endanger life or result in serious injury. They are indicated by this icon. Use of this pump with radioactive chemicals is forbidden!
More informationForeign language versions available online at:
INSTALLATION & OPERATION MANUAL INLET STABILIZER DAMPENER ( J MODEL) SENTRY dampeners are pressure vessels containing a flexible bladder or bellows inside that separates an inert pressurized gas (air or
More informationCash Valve. Type G-4. Pilot Operated Pressure Reducing Regulator for Steam, Air and Gases. Flow Control
Cash Valve Type G-4 Pilot Operated Pressure Reducing Regulator for Steam, Air and Gases Issued - March 2001 CAVMC-0512-US-0609 ISO 9001 Certified Flow Control Description FIG 2042 - Bronze FIG 2043 - Bronze
More informationCash Valve TYPE G-4 PILOT OPERATED PRESSURE REDUCING REGULATOR FOR STEAM, AIR AND GASES. ISSUED - MARCH 2001 CAVMC-0512-US-0208 ISO 9001 Certified
Cash Valve TYPE G-4 PILOT OPERATED PRESSURE REDUCING REGULATOR FOR STEAM, AIR AND GASES ISSUED - MARCH 2001 CAVMC-0512-US-0208 ISO 9001 Certified TYPE G-4 DESCRIPTION FIG 2042 - Bronze FIG 2043 - Bronze
More informationDataSheet. Series AA Electronic Metering Pumps. Configuration Data. Dimensions. Specifications. Model AA HI. ISO 9001 Certified
DataSheet Series AA Electronic Metering Pumps Configuration Data Model AA 9 4 1-358HI Control Code 1 --- Manual Control: Speed (stroking frequency) and stroke length manually adjustable. 7 --- Instrument
More informationPrecision and Instrument Regulators 1/4" port size
Section 8 Precision and Instrument Regulators /" port size Contents -8 Precision Air Pressure Regulator /" ports............ale-8-2 R38 Instrument Regulator Aluminum Model /" ports.........ale-8- -8 R38
More informationInstallation and Operation Manual Chargeable Dampener Models
Installation and Operation Manual Chargeable Dampener Models SENTRY dampeners are pressure vessels containing a flexible bladder or bellows inside that separates an inert pressurized gas (air or Nitrogen)
More informationOPERATION MANUAL. ALUMINUM Models 316 S.S. Models AIR-OPERATED DOUBLE DIAPHRAGM PUMPS
OPERATION MANUAL 2 METALLIC PUMP (BOLTED) PWR-FLO TM AIR DISTRIBUTION SYSTEM NPF50 AIR-OPERATED DOUBLE DIAPHRAGM PUMPS ALUMINUM Models 316 S.S. Models A JDA Global Company CAUTIONS - READ FIRST CAUTION:
More informationInstallation and Operation Manual
Installation and Operation Manual Chargeable Dampener Models SENTRY dampeners are pressure vessels containing a flexible bladder or bellows inside that separates an inert pressurized gas (air or Nitrogen)
More informationAir Operated Hydraulic Pumping Systems to 50,000 psi
High Pressure Equipment Air Operated Hydraulic Pumping Systems to 50,000 psi PS-10: 10,000 psi PS-20: 20,000 psi PS-30: 30,000 psi PS-40: 40,000 psi PS-50: 50,000 psi PS-90: 90,000 psi High Pressure air
More informationBooster Regulator/Air Tank
Booster Regulator/Air Tank Increase factory air pressure by up to 4 times! Air-only operation requires no power supply, reduces heat generation, and Boost pressure allows easy installation. NEW Renewed
More informationtel: fax: web:
Tri-Flex 2 Five-Cell Permeability Test System For high volume commercial laboratory testing, the Tri-Flex 2 Five-Cell Permeability Test System offers the user the capabilities to test up to five samples
More informationP400/PX400. Advanced Series METAL Pumps. Advance your process. Engineering Operation & Maintenance WIL E-07 REPLACES WIL E-06
P400/PX400 Advanced Series METAL Pumps Engineering Operation & Maintenance Advance your process WIL-11210-E-07 REPLACES WIL-11210-E-06 TABLE OF CONTENTS SECTION 1 CAUTIONS READ FIRST!..............................................1
More informationFILTER TYPE PRESSURE SNUBBER
FILTER TYPE PRESSURE SNUBBER Pressure oscillations and other sudden pressure changes can affect the delicate mechanisms of a pressure gauge or pressure transmitter. This can result in either complete failure
More informationINDUSTRIAL TRANSFER PUMPS
INDUSTRIAL TRANSFER PUMPS Diaphragm Transfer Pumps - Plastic Body Pumps - Metal Body Pumps - Hygienic Pumps - High Pressure Pumps - Powder Pumps PLASTIC BODY PUMPS Diaphragm pumps also run trouble-free
More informationBest Practices for Installation of Gaseous Sample Pumps
Best Practices for Installation of Gaseous Sample Pumps Goal of the Gas Sample Pump Transport a clean, reliable, sample of the process gas to the analyzer, in the safest and easiest way possible, to ensure
More informationRESIDENTIAL - IRRIGATION - WATER TREATMENT OF FLORIDA PUMP PROTECTION - EFFICIENCY - ENERGY SAVER - COMFORT
OF FLORIDA Pressure Gauge Dry Pressure gauge DRY Steel casing Lower mount PG060L20D4M 1/4" LOWER MOUNT METAL 2" 0-60 PSI 100 0.21 PG100L20D4M 1/4" LOWER MOUNT METAL 2" 0-100 PSI 100 0.21 Pressure gauge
More informationPILOT OPERATED PRESSURE VACUUM RELIEF VALVE MODEL 1660
PILOT OPERATED PRESSURE VACUUM RELIEF VALVE MODEL 1660 Patent Protected Premium Seat Tightness to Set Pressure Snap or Modulating Valve Action Provides Ability to Meet Clean Air Act Requirements 600 TYPICAL
More informationPRO-50 Instrument Supply Regulator
Features CRN Approved The PRO-50 Regulator has been granted a Canadian Registration Number. Sour Service Capability Available in NACE configurations that comply with NACE MR0175/MR0103. Environmental limits
More informationINSTALLATION & OPERATION MANUAL
INSTALLATION & OPERATION MANUAL DAMPENER (XPX HIGH PRESSURE MODEL) SENTRY dampeners are pressure vessels containing a flexible bladder or bellows inside that separates an inert pressurized gas (air or
More informationFAST & FLEXIBLE EXPERTISE 100% ORDER FULFILLMENT LOW COST PROVIDER
FAST & FLEXIBLE JDA Global LLC (EST. 0) serves as the world s largest & most experienced after-market diaphragm pump products provider. We leverage our deeply embedded industry knowledge each day to bring
More informationPressure Reducing Valves Pressure Reducing with. Broady Flow Control. D Series Range. Pressure Reducing Valves. Broady Flow Control
Pressure Reducing Valves 00 Pressure Reducing with Broady Flow Control D Series Range Pressure Reducing Valves Broady Flow Control The Company Broady Flow Control is an Independent Valve Manufacturer,
More informationThe Shand & Jurs Model Vapor Guard Tank Blanketing Valve
Lower maintenance due to fewer parts Occupies less space, less stress to tank Teflon is inert to most chemicals; extends service life Simplifies and lowers maintenance cost Optimizes flow of blanketing
More informationSG3 Series Regulators - Pressure Reducing
SG3 Series Regulators - Pressure Reducing DSG333X1 Specifications For questions about this product, please consult TESCOM. OPERATING PARAMETERS Pressure rating per criteria of CGA E-4; ASME B31; ASME BPVC
More informationBrooks Flow Controllers for Gas and Liquid Service Model FC 8744, Series FC 8800 and FC 8900
Data Sheet Flow Controllers for Gas and Liquid Service Brooks Flow Controllers for Gas and Liquid Service Model FC 8744, Series FC 8800 and FC 8900 Features and Benefits Flow controllers for high pressure
More informationVACUUM REGULATORS CONTENTS
CAD drawing data catalog is available. ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS CONTENTS Small Regulators Features 759 Specifications, Order Codes, Flow Rate
More informationPetro-Chemical & Analyzer Sampling Systems
Petro-Chemical & Analyzer Sampling Systems Pressure control solutions for your industry. The Tescom brand offers a comprehensive range of regulators, valves and changeover systems that are ideal for analyzer
More informationPetro-Chemical & Analyzer Sampling Systems
Petro-Chemical & Analyzer Sampling Systems Pressure control solutions for your industry. The Tescom brand offers a comprehensive range of regulators, valves and changeover systems that are ideal for analyzer
More informationHAYWARD FLOW CONTROL Series PBV Back Pressure Valve and Series RPV Pressure Relief Valve INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS
HAYWARD FLOW CONTROL Series PBV Back Pressure Valve and Series RPV Pressure Relief Valve INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS Page 1 of 20 Page 2 of 20 TABLE OF CONTENTS Safety Warnings
More informationOPERATOR S MANUAL
OPERATOR S MANUAL 1604619 INCLUDING: OPERATION, INSTALLATION & MAINTENANCE RELEASED: 11-1-13 REVISED: 3-03-14 (REV. B) 1/4" DIAPHRAGM PUMP 1:1 RATIO (NON-METALLIC) 1604628 READ THIS MANUAL CAREFULLY BEFORE
More informationP800/PX800. Advanced Series METAL Pumps. Advance your process. Engineering Operation & Maintenance WIL E-12 REPLACES WIL E-11
P800/PX800 Advanced Series METAL Pumps Engineering Operation & Maintenance Advance your process WIL-11220-E-12 REPLACES WIL-11220-E-11 TABLE OF CONTENTS SECTION 1 CAUTIONS READ FIRST!..............................................1
More informationThe "BETA AIR RELAY"
SP251.C 1/9 The "BETA AIR RELAY" The pressure operated AIR RELAY Specially designed for: Valve Control Offshore & Onshore Zone 0 applications Products and specifications are liable to be changed without
More informationFLOAT OPERATED LEVEL CONTROLLER
PNEUMATIC LEVEL SWITCH APPLICATION: Liquid level controller for oil and gas separators, water knockouts, gas scrubbers and accumulators. FEATURES: Rated for 2000 psi working pressure Push-button dump valve
More informationNeed the part number for an impeller, seal, gasket, or motor? It s all here.
Check here for parts questions Flexible Impeller Reference Guide Service Parts & Kits Service & Warranty Information 92 Need the part number for an impeller, seal, gasket, or motor? It s all here. Highlights:
More informationCash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified
Cash Valve PILOT OPERATED BACK PRESSURE VALVE ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 01 Certified KP HIGH CAPACITY PILOT OPERATED BACK PRESSURE VALVE DESCRIPTION The Cash Valve Type KP is a pilot
More informationDirect Operated Precision Regulator Modular Style. Standard Specifications
1 Direct Operated Precision Regulator Modular Style Series P3 Courtesy of Steven Engineering, Inc.-23 Ryan Way, South San Francisco, CA 948-637-Main Office: (65) 588-92-Outside Local Area: (8) 258-92-www.stevenengineering.com
More informationEOM PX1500. Engineering Operation & Maintenance. Advanced Series Metal Pump. WIL E-10 Replaces WIL E-09
EOM Engineering Operation & Maintenance PX1500 Advanced Series Metal Pump W h e r e I n n o v a t i o n F l o w s. www.wildenpump.com WIL-11230-E-10 Replaces WIL-11230-E-09 TABLE OF CONTENTS SECTION 1
More informationA050-1/2 INCH AIR OPERATED double DIAPHRAGM PUMP
A050 - /2 INCH AIR OPERATED double DIAPHRAGM PUMP A050 /2 Pump /2 Aluminum NPT or BSP Connections Zinc Plated Hardware Non-Metallic Muffler Suction Right / Discharge Right Standard Porting SPECIFICATIONS
More informationFLOAT OPERATED LEVEL CONTROLLER
PNEUMATIC LEVEL SWITCH NO RELAY APPLICATION: Liquid level controller for oil and gas separators, water knockouts, gas scrubbers and accumulators. FEATURES: Push-button dump valve override standard Float
More informationP400/PX400. Advanced Series METAL Pumps. Advance your process. Engineering Operation & Maintenance WIL E-12 REPLACES WIL E-11
P400/PX400 Advanced Series METAL Pumps Engineering Operation & Maintenance Advance your process WIL-11210-E-12 REPLACES WIL-11210-E-11 TABLE OF CONTENTS SECTION 1 CAUTIONS READ FIRST!..............................................1
More informationModel 4000 Pressure Controller
FEATURES Multiple Configurations The 4000 series pressure controller can be configured into either proportional only or proportional plus reset mode with a minimum of parts. Rugged Design Die cast aluminum
More informationMark 630 Series. High Pressure Regulators Mark 630 High Pressure Regulators. High Pressure Regulators. Features
Mark 630 Series High Pressure Regulators The Jordan Mark 630 self-operated pressure reducing regulator is designed to provide tight shutoff and accurate regulation on high pressure gas systems. It can
More informationWHITE PAPER Overview of Diaphragm and Chemical Seals
WHITE PAPER Overview of Diaphragm and Chemical Seals WHITE PAPER Overview of Diaphragm and Chemical Seals Introduction A diaphragm or chemical seal is a device comprised of a thin membrane known as a diaphragm,
More informationSG1 Series Regulators - Pressure Reducing
SG1 Series Regulators - Pressure Reducing DSG131X Specifications For questions about this product, please consult TESCOM. OPERATING PARAMETERS Pressure rating per criteria of CGA E-; ASME B31; ASME BPVC
More informationProduct Data Screwed Valves
Screwed Valves Brass and Chrome PVC Stainless Steel Flow Control Check Valves - 15mm Flow Control Check Valves - 25mm AUSTRALIA Maric Brass & Chrome Screwed Valves p. 28 Availability & Specifications Maric
More informationLiquid ring vacuum pumps in compact design
Liquid ring vacuum pumps in compact design, Pressure range: Suction volume flow: 33 to 113 mbar 3 to 58 m³/h CONSTRUCTION TYPE SIHI liquid ring vacuum pumps are displacement pumps of uncomplicated and
More informationTechnical Process Bulletin
Technical Process Bulletin RIDOLINE 53 Alkaline Immersion Cleaner 1. Introduction: Technical Process Bulletin No. 234242 This Revision: 23-11-1990 RIDOLINE 53 is a powdered, silicated, alkaline immersion
More informationChoosing the right miniature instrument and control valve is a snap
Choosing the right miniature instrument and control valve is a snap INVALCO Micro Valve The Micro Valve is a unique miniature valve offering versatility and rugged construction. Since its introduction
More informationALE-40. R06 Miniature Brass Body Regulator. Water and Compressed Air Service 1/8" and 1/4" PTF Port Sizes. Air line equipment.
Air line equipment R Miniature Brass Body Regulator Water and Compressed Air Service 1/" and 1/" PTF Port Sizes Compact design, corrosion resistant construction Brass body with choice of plastic or brass
More informationFloWash. Industrial Filter Cart
OPERATION AND MAINTENANCE MANUAL FloWash Industrial Filter Cart Read all instructions before installation or operation of equipment. Failure to comply with these instructions could result in bodily injury
More informationRK-IR Sample Draw Aspirator Adapter Operator s Manual
30-0951RK-IR Sample Draw Aspirator Adapter Operator s Manual Part Number: 71-0018RK Revision: A Released: 6/2/10 www.rkiinstruments.com Product Warranty RKI Instruments, Inc. warrants gas alarm equipment
More informationDiaphragm Accumulators
Diaphragm Accumulators HYDAC Diaphragm Accumulators Index Page 1. Description 3 Introduction 3 Construction 3 2. Applications 4 3. Technical Data 6 Operation 6 Technical Specifications 6 Temperature Effect
More informationDEPA Air Operated Diaphragm Pumps
DEPA Air Operated Diaphragm Pumps Series M Type DL Cast Metal Pumps DEPA air operated diaphragm pumps made of cast metal are the best suitable solution for most industrial applications. Many years experience
More informationCSA Sample Draw Aspirator Adapter Operator s Manual
30-0951-CSA Sample Draw Aspirator Adapter Operator s Manual Part Number: 71-0367 Revision: 0 Released: 4/30/15 www.rkiinstruments.com WARNING Read and understand this instruction manual before operating
More informationPRESSURE & TEMPERATURE GAUGES PRESSURE TEMPERATURE. Catalogue H20200a
PRESSURE & TEMPERATURE GAUGES PRESSURE Catalogue TEMPERATURE Applications The label Trafag Industrial Components extends the Trafag brand name to instruments manufactured by qualified partner companies.
More informationRK LEL Sample Draw Aspirator Adapter Operator s Manual
30-0951RK LEL Sample Draw Aspirator Adapter Operator s Manual Part Number: 71-0017RK Revision: A Released: 6/2/10 www.rkiinstruments.com Product Warranty RKI Instruments, Inc. warrants gas alarm equipment
More informationR133 HELYON. Brass high pressure regulator, suitable for compressed air, gas and liquid
R133 Brass high pressure regulator, suitable for compressed air, gas and liquid HELYON 5 Chemin du Jubin 6957 DARDILLY Tél. +33 () 7 5 16 7 - Fax +33 () 7 5 16 71 FEATURES High pressure regulator for cylinder
More informationTECHNICAL DATA. Page 1 of 12
Page 1 of 12 1. DESCRIPTION The Viking Regulating Valve is a direct-acting, single-seated, spring-loaded diaphragm valve. When installed as a pilot regulating valve on a Viking Model H or J Flow Control
More informationSG2 Series Regulators - Pressure Reducing
SG2 Series Regulators - Pressure Reducing DSG2232X Specifications For questions about this product, please consult TESCOM. OPERATING PARAMETERS Pressure rating per criteria of CGA E-; ASME B31; ASME BPVC
More informationANDERSON GREENWOOD SERIES 9000 POSRV INSTALLATION AND MAINTENANCE INSTRUCTIONS
Procedure-assembly-functional test and performance requirements 1 SCOPE 1.1 This document establishes the general procedure for assembly, functional testing and normal performance requirements of low Series
More informationFOAM TANK (1/2) DATA SHEET
FIRE FIGHTING EQUIPMENT DATA SHEET FOAM TANK (1/) DATA SHEET JOB NO. : RFQ. NO. : ISSUE : SHEET OF 01 CUSTOMER : ITEM NO. : 0 PROJECT : QUANTITY : 0 LOCATION : SERVICE : FOAM SYSTEM 0 05 CODE & STANDARDS
More informationPneumatic Powered - Plunger Pumps
Models 42/62/82 D Series P.O. Box 80769 Lafayette, LA 70598-0769 (337) 235-9838 FAX (337) 235-9852 www.sidewinderpumps.com Pneumatic Powered - Plunger Pumps Suggested Installation & Operating Instructions
More informationDiaphragm Accumulators
Diaphragm Accumulators. DESCRIPTION.. FNCTION Fluids are practically incompressible and cannot therefore store pressure energy. The compressibility of a gas is utilised in HYDAC diaphragm accumulators
More informationApplication and Sizing
Application and Sizing Energy accumulator: It is improbable that an hydraulic system use all of its capacity without interruptions. An hydropneumatic accumulator can store a certain amount of fluid that
More informationSABERINDO PACIF SABERINDO PACIFIC CIFIC SABERINDO PA. A Tyco International Company
CIF A Tyco International Company 1 Foam Concentrate CIF 3% AFFF -UL Listed -UL Canada Listed 6% AFFF 6 parts AFFF concentrate to 94 parts water -UL Listed- Foam Liquid -UL Canada Listed 3% FLUOROPROTEIN
More informationImpeller Replacement -
10 www.jabsco.com Introduction Jabsco - The Original Impeller Jabsco flexible impellers can be fitted to most makes and models of bronze flexible impeller engine cooling, bilge, transfer and general purpose
More informationKDV HIGH ACCURACY GLASS TUBE ROTAMETER
KDV HIGH ACCURACY GLASS TUBE ROTAMETER Flow Pressure Level Temperature measurement monitoring control S2 Industrial and Sanitary Designs Body Sizes 1/2 Through 2 Reliable, Time Proven Glass Tube Design
More informationsafety shut-off Valve HON 703 / HON 704
safety shut-off Valve HON 703 / HON 704 Product information serving the gas industry worldwide Applications, characteristics, technical data Applications Main safety device in gas pressure regulating systems
More informationOWNER S TECHNICAL MANUAL
EL SERIES OWNER S TECHNICAL MANUAL DP7002 1 Air Operated Diaphragm Pump Description The DP7002 1 air operated diaphragm pump is the ideal device for the pumping, transfer and dispensing of chemical liquids,
More information12 Impeller Replacement
144 Impeller Replacement INTRODUCTION Jabsco The Original Impeller Jabsco Flexible Impellers can be fitted to most makes and models of bronze flexible impeller engine cooling, bilge, transfer and general
More informationWallace & Tiernan Flow Measurement Equipment
Water Technologies Wallace & Tiernan Flow Measurement Equipment Glass Tube Varea-Meter Units Features Rugged, One-Piece Enclosure The welded, deep-formed frame is heavy gauge 302 stainless steel. It protects
More informationBladder Accumulators. General Information. Bladder Accumulators. Introduction. Accumulator Function. Why use a Bladder Accumulator?
General Information Introduction Accumulator unction Bladder accumulators provide a means of regulating the performance of a hydraulic system. The design of the Stauff bladder accumulator makes use of
More informationPressure Independent Control Series
Document No. 155-522 Pressure Independent Control Series Two-Way Cast Iron Flanged Bodies, ANSI 125 and 250 Description Siemens Pressure Independent Control Valves integrate three functions into a single
More informationBladder Accumulators High pressure
Bladder Accumulators High pressure 1. DESCRIPTION 1.1. FUNCTION Fluids are practically incompressible and cannot therefore store pressure energy. The compressibility of a gas (nitrogen) is utilised in
More informationTECHNICAL DATA. Low-Flow Foam Preaction System with Hydraulically Actuated Concentrate Control Valve.
Foam 302 a 1. DESCRIPTION (Refer to Figure 1 on page 302 e.) The Viking Low-Flow Foam/Water Proportioning System is a UL Listed and FM Approved system, for use with 3M and Viking brand foam concentrate.
More informationOPERATION MANUAL AIR-OPERATED DOUBLE DIAPHRAGM PUMPS 1.5 POLYPROPYLENE PUMP PWR-FLO TM AIR DISTRIBUTION SYSTEM NPF40 CLAMPED. A JDA Global Company
OPERATION MANUAL 1.5 POLYPROPYLENE PUMP PWR-FLO TM AIR DISTRIBUTION SYSTEM NPF40 CLAMPED AIR-OPERATED DOUBLE DIAPHRAGM PUMPS A JDA Global Company CAUTIONS - READ FIRST CAUTION: Do not apply compressed
More informationFOAM TANK (1/2) DATA SHEET
FIRE FIGHTING EQUIPMENT DATA SHEET FOAM TANK (1/2) DATA SHEET JOB NO. : RFQ. NO. : ISSUE : SHEET OF 01 CUSTOMER : ITEM NO. : 02 PROJECT : QUANTITY : 03 LOCATION : SERVICE : FOAM SYSTEM 04 05 CODE & STANDARDS
More informationINSTALLATION AND OPERATING INSTRUCTIONS
INSTALLATION AND OPERATING INSTRUCTIONS For 3D Instruments Direct Drive Pressure Gauges 3D Instruments Inc., 15542 Chemical Lane, Huntington Beach, CA, 92649, U.S.A. Tel. (714) 894-5351, Fax. (714) 895-4309
More informationPX1500. Advanced Series METAL Pumps. Advance your process. Engineering Operation & Maintenance. WIL E-02 Replaces WIL E-01
PX1500 Advanced Series METAL Pumps Engineering Operation & Maintenance Advance your process WIL-11230-E-02 Replaces WIL-11230-E-01 TABLE OF CONTENTS SECTION 1 CAUTIONS READ FIRST!..............................................1
More informationMaximum 0.85 MPa pressure setting Long-life, high flow perfect for balancer applications
Outstanding performance in extremely low pressure and low pressure ranges from 0.003 to. Realizing high performance, energy saving, and compact size. Realize precise pressure control in a pressure range
More informationSERIES 30. Spring Operated Tank Blanketing Valve PROTECTOSEAL.
SERIES 30 PROTECTOSEAL 1 2" NPT inlet and outlet standard Direct acting valve mechanism Optional flanged or threaded inlet and outlet connections available Inlet gas pressures from 10 PSIG to 200 PSIG
More informationVersa-Surge Surge Suppressors for Air-Driven Diaphragm Pumps
SER & OPERTG MUL ersa-surge Surge Suppressors for ir-driven Diaphragm Pumps Metallic Construction Table of Contents Product and Operating Principle... Product omenclature Description...2, 3 Materials and
More informationSeries IRV1000/2000/3000
CAT.ES60-16 A Regulator Series /2000/3000 Allows adjustment of vacuum line pressure Regulator Series /2000/3000 3 sizes offered in the series Variations have been expanded to three sizes from only one
More informationOFI Testing Equipment - Aging Cell Instructions Page 1 of 4. Instructions OFITE AGING CELLS
OFI Testing Equipment - Aging Cell Instructions Page 1 of 4 Instructions OFITE AGING CELLS The OFITE Aging Cell is a patented pressure vessel that enables samples to be subjected to temperatures higher
More informationTECHNICAL DATA. than the water inlet pressure to the concentrate
Foam102a 1. DESCRIPTION The Viking Low Flow Foam/Water proportioning system, is a UL Listed and FM Approved system, for use with 3M foam concentrates. This system consists of a standard wet pipe sprinkler
More information553 Series.
38467.03 www.caleffi.com Pre-adjustable filling units Copyright 01 Caleffi 3 Series Function The automatic filling valve is a device consisting of a pressure reducing valve with compensating seat, visual
More informationInstruction Manual. Standard Surge Eliminator. Standard X. Flushable X - X
Standard Surge Eliminator Standard 104052 - X Flushable 104053 - X - X Page 2 of 16 Issue: 2.3 Index Section 1.1 General Description 1.2 Operating Principle 1.3 Specification 1.4 Fitting Selection - Standard
More informationPMI Advanced Automated. Pulse Decay Permeameter APDP-10K-HP-101. Not just products... Solutions!
PMI Advanced Automated Pulse Decay Permeameter APDP-10K-HP-101 Not just products... Solutions! DESCRIPTION The PMI s Advanced automated pulse decay Permeameter is used to measure gas permeability of samples
More informationTest pumps. Pressure sources. Good reasons for proper and reliable calibration
Test pumps Pressure is one of the most commonly measured quantities in engineering, which is why exact and reliable pressure measurement is especially important. However, the characteristics of the even
More informationDescription Advanced Features Typical Applications
Series single stage, brass barstock line regulator Description Advanced Features Typical Applications The Series regulators are intended for secondary pressure control of noncorrosive, high purity or liquefied
More informationTotal Pressure Regulator Solutions.
Total Pressure Regulator Solutions www.pressure-tech.com Working with customers to support their exact needs A pressure regulator is a critical component in any fluid control system. At Pressure Tech,
More informationMV-Series High-Pressure Valves USER GUIDE
MV-Series High-Pressure Valves USER GUIDE 369 Syringa Ridge Sandpoint, ID 83864 281.782.8312 www.vindum.com support@vindum.com V:1.0 (6-27-17) This page is intentionally blank. Copyright 2017 Vindum Engineering,
More informationBuying more than 11 gauges? Call Lesman for additional discounts.
Low Cost Liquid Filled Pressure Gauges Size: 1.5", 2", and 2.5" Accuracy: 2.5% of full scale Materials: Case and ring: 304 stainless steel; Window: Polycarbonate; Seals: Buna-N; Pointer: Black-finished
More information