Panel-Mounting Flowmeters Purge Set (Flowmeter with Constant Flow Valve)

Size: px
Start display at page:

Download "Panel-Mounting Flowmeters Purge Set (Flowmeter with Constant Flow Valve)"

Transcription

1 Panel-Mounting Flowmeters Purge Set (Flowmeter with Constant Flow Valve) When working pressure change, inside diaphragm and needle valve operates in order to always keeping a fixed flow rate for exact measurement of constant flow setting, level, density. FKP Series Specification: 1. Accuracy: ±2% of F.S Indicator ) 2. Max. Operating Pressure: Max. 10kgf/cm 2 G 3. Max. Operating Temperature: Max. 120 C (300 C Option) 4. Operating Differential Pressure Range: 0.5~3kgf/cm 2 G, 0.3~3kgf/cm 2 G, 0.6~4kgf/cm 2 G, 1~5kgf/cm 2 G Operation Principle: In the PRIMARY(INLET) PRESSURE VARIATION CONTROL TYPE, the fluid, of which inlet pressure varies, is introduced from IN to the lower chamber of the С series Constant Flow Valve. The load pressure (Secondary pressure) is connected to the upper chamber. The differential pressure between the lower chamber and the upper chamber is always constant thanks to the function of the Spring and the Diaphragm. The differential pressure across the needle valve is kept always constant and the flow rate of the fluid is proportional only to the opening of needle valve. The opposite action is taken for SECONDARY (OUTLET) PRESSURE VARIATION CONTROL TYPE and the flow rate is kept also constant even when the load pressure changes.

2 SUPPLY PRESSURE VARIATION LEVEL MEASUREMENT As shown above, in case one large supply line branches into several lines and the supply pressure changes because of stoppage of some branches. Primary Pressure Variation type Purge set will be suitable in keeping the purging volume of fluid. Liquid level in tanks is measured by the Backpressure at the edge of purging pipe. The outlet pressure at the tank bottom changes depending on the liquid level, and constant bubbling is required. Thus, Secondary Pressure Variation type purge set is used for this application. A Dp transmitter is often connected to pressure line instead of pressure gauge for remote transmission. PURGING FOR ORIFICE PLATE APPLICATION DENSITY MEASUREMENT For the measurement of flaw rate of corrosive liquids and/or liquids with solids by orifice plate, an equal pressure purging both to High and Low pressure parts so as not to introduce liquid and/or solids into Dp by pass line. Dual mount type purge set used. For continuous measurement of density of liquid in tanks. purging system is used as shown above.

3 Panel-Mounting Flowmeters FKP2 series (Purge Set) Model Code: FКР2 Code Description Indicator FKOI Glass Tube Indicator FKMS Metal Tube Indicator A 130mm of FKOI Series Connection С 200mm of FKOI Series Length D 240mm of FKOI Series MF 180mm of FKMS Series 1 SUS304 Material 2 SUS3I6 X Special Option IN Inlet Control OUT Outlet Control Standard Specification: Model Identification : Inlet pressure variation control type Outlet pressure variation control type Available Flow Ranges: Liquids:Max. 2L/min *1 Gases: Max. 50L/min (nor) *2 Max. Oper. Press.: 1.0 MPa (10kg/cm 2 G) Temp.: Max. I20 C Min. Required DP: 0.06MPa (0.6kg/cm 2 G) Max. Controllable DP : 0.4MPa (4kg/cm 2 ) Control Accuracy: ±3% of F.S *1: Water (Density 1.0 g/cm 2, Viscosity 1.0cP) *2:, 0 C, 1atm Standard Specification: Part Name Material Standard Option Body SCSI 4 - Diaphragm CR VITON Spring SUS304 SUS316 Seal NBR VITON, PTFE Standard Process Connection: PT 1/4 Thread

4 Structure & Dimensions: Inlet Pressure Variation Control Type (Also used for Outlet Pressure Variation in liquid applications) FKP2-FKOI-A-1-IN Water Min ~0.03L/min. Max. 0.4~2 L/min. Water Min ~0.07L/min. FKP2-FKOI-C-1-IN Max. 0.2~2 L/min. (0 C, 1atm.) Max. 5~50 NL/min. Inlet Pressure Variation Control Type (Also used for Outlet Pressure Variation in liquid applications) FKP2-FKOI-D-1-IN Water Min ~0.03L/min. Max. 0.4~2 L/min. Water Min ~0.07L/min. FKP2-FKMS-MF-1-IN Max. 0.2~2 L/min.

5 Outlet Pressure Variation Control Type FKP2-FKOI-A-1-OUT FKP2-FKOI-C-1-OUT Outlet Pressure Variation Control Type FKP2-FKOI-D-1-OUT FFKP2-FKMS-MF-1-OUT

C-21 C-22. Gases and liquids ~0.4 ±5 Rc 1/ It is general data, and the maximum temperature may change by terms of use and environment.

C-21 C-22. Gases and liquids ~0.4 ±5 Rc 1/ It is general data, and the maximum temperature may change by terms of use and environment. TO MATA CONSTANT FOW C Series PURGE SET FOWMETER WITH CONSTANT FOW VAVE GENERA C series Constant Flow Valves keep flow rate of gases or liquids even when the supply or load pressure changes. Control valve

More information

C-21 C-22. Gases and liquids ~0.4 5 Rc 1/4 thread 0.9

C-21 C-22. Gases and liquids ~0.4 5 Rc 1/4 thread 0.9 T MATA CNTANT FW C eries PURGE ET FWMETER WITH CNTANT FW VAVE GENERA C series Constant Flow Valves keep flow rate of gases or liquids even when the supply or load pressure changes. Control valve with diaphragm

More information

Model 2851 CONSTANT FLOW REGULATOR

Model 2851 CONSTANT FLOW REGULATOR CONSTANT FLOW REGULATOR Model 2851 The model 2851 constant flow regulator is designed to provide constant flow of liquids or gases regardless of pressure variations. It is intended for low liquid flows

More information

Measurement of Low GAS & Liquid Flows

Measurement of Low GAS & Liquid Flows Measurement of Low GAS & Liquid Flows The Measurement Measurement with a float in a tapered borosilicate glass tube. Series 2100 with a 100 mm flow tube Series 2150 with a 150 mm flow tube Series 2300

More information

Glass tube flowmeters Series 2000

Glass tube flowmeters Series 2000 Glass tube flowmeters Series 2000 Variable area flowmeter for low flows of liquids and gases Short mounting length and compact construction, especially indicated for control panels Easy installation. No

More information

Glass tube flowmeters Series 2000 Variable area flowmeter for low flows of liquids and gases

Glass tube flowmeters Series 2000 Variable area flowmeter for low flows of liquids and gases Glass tube flowmeters Series 2000 Variable area flowmeter for low flows of liquids and gases Short mounting length and compact construction, especially indicated for control panels Easy installation. No

More information

TC Series FOR THE MASS FLOW CONTROL OF ALL KIND OF GASES THERMAL MASS FLOW CONTROLLER GENERAL FEATURES OPERATION PRINCIPLE

TC Series FOR THE MASS FLOW CONTROL OF ALL KIND OF GASES THERMAL MASS FLOW CONTROLLER GENERAL FEATURES OPERATION PRINCIPLE FOR THE MASS FLOW CONTROL OF ALL KIND OF GASES TC Series THERMAL MASS FLOW CONTROLLER GENERAL TC series are thermal mass flow controllers, a combination of thermal mass flowmeter and control valve. TC

More information

CASH VALVE TYPE KP BACK PRESSURE VALVES

CASH VALVE TYPE KP BACK PRESSURE VALVES A high capacity pilot operated back pressure valve that offers accurate control and dependable protection against overpressure conditions FEATURES Automatically maintains maximum pressure in a vessel or

More information

Flow control valves Series RFU - RFO 2/

Flow control valves Series RFU - RFO 2/ CATALOGUE > Release 8.5 > Valves Series RFU - RFO Flow control valves Series RFU - RFO Unidirectional and bidirectional flow control valves Ports: M5, G1/8, G1/4, G3/8 and G1/ Nominal diameter: M5 = 1,5

More information

Description Advanced Features Typical Applications

Description Advanced Features Typical Applications Series single stage, brass barstock line regulator Description Advanced Features Typical Applications The Series regulators are intended for secondary pressure control of noncorrosive, high purity or liquefied

More information

TC Series FOR THE MASS FLOW CONTROL OF ALL KIND OF GASES THERMAL MASS FLOW CONTROLLER OUTLINE FEATURES OPERATION PRINCIPLE

TC Series FOR THE MASS FLOW CONTROL OF ALL KIND OF GASES THERMAL MASS FLOW CONTROLLER OUTLINE FEATURES OPERATION PRINCIPLE FOR THE MASS FLOW CONTROL OF ALL KIND OF GASES TC Series THERMAL MASS FLOW CONTROLLER OUTLINE TC series are thermal mass flow controllers, a combination of thermal mass flowmeter and control valve. TC

More information

The Discussion of this exercise covers the following points:

The Discussion of this exercise covers the following points: Exercise 3-2 Orifice Plates EXERCISE OBJECTIVE In this exercise, you will study how differential pressure flowmeters operate. You will describe the relationship between the flow rate and the pressure drop

More information

BULLETIN FOR ACCURATE INDICATION AND CONTROL OF GAS AND LIQUID FLOW IN LOW RANGES.

BULLETIN FOR ACCURATE INDICATION AND CONTROL OF GAS AND LIQUID FLOW IN LOW RANGES. BULLETIN 20-7000 ROTAMETERS PURGE FOR ACCURATE INDICATION AND CONTROL OF GAS AND LIQUID FLOW IN LOW RANGES. INTRODUCTION McCrometer purge rotameters are precision-made instruments designed to accurately

More information

MODEL HICV-130Ti7-331N. Lot NAGOYA JAPAN PAT.

MODEL HICV-130Ti7-331N. Lot NAGOYA JAPAN PAT. MODEL 9 The HICV Series of self control valves are highly accurate, maintaining a constant rate of outlet pressure and flow regardless of variations in pressure at the point of entry. Creation of reliable

More information

Multiple Tube Flowmeters

Multiple Tube Flowmeters Multiple Tube Flowmeters xp The model xp multiple tube flowmeter line offers, the convenience and simplicity of 2, 3, 4, 5 and 6 tube meters, retaining most of the unique design features associated with

More information

Radar, Ultrasonic and RF Level Transmitters

Radar, Ultrasonic and RF Level Transmitters Radar, Ultrasonic and RF Level Transmitters Both measures the time it takes the wave to travel between the transmitter and that reflected wave off the surface of the material to reach the transmitter again.

More information

LMU100/200 Series. Standard Specifications

LMU100/200 Series. Standard Specifications Mist Spray Unit MU/ Series Intermittent spray to cutting and press gear chains, etc. Standard Specifications Inlet air Oil tank set range Oil Dynamic viscosity of oil ( C) Oil tank capacity (cm ) mbient

More information

Displacement. from 2 up to 6 sections balanced, unbalanced from 0.8 to 31 ccm FLOW DIVIDERS

Displacement. from 2 up to 6 sections balanced, unbalanced from 0.8 to 31 ccm FLOW DIVIDERS Displacement from 2 up to 6 sections balanced, unbalanced from 0.8 to 31 ccm FLOW DIVIDERS DP Catalogue of flow dividers DP TABLE OF CONTENTS GENERAL DESCRIPTION........................................................................................................

More information

Pressure reducing valve, direct operated, type DR 5 DP Huade América 1

Pressure reducing valve, direct operated, type DR 5 DP Huade América 1 Pressure reducing valve, direct operated, type DR 5 DP Huade América 1 BEIJING HUADE HYDRAULIC INDUSTRIAL GROUP CO.,LTD. Pressure reducing valve, direct operated, type DR 5 DP Size 5 up to 31.5MPa up to

More information

Integral type Differential pressure flowmeter VNT Series

Integral type Differential pressure flowmeter VNT Series Integral type Differential pressure flowmeter VNT Series OUTLINE VH series Wafer-Cone differential pressure flowmeter and high precision differential pressure transmitter are integrated into one flowmeter.

More information

Pressure Equalising Valves Model , for Differential Pressure Gauges

Pressure Equalising Valves Model , for Differential Pressure Gauges Accessories Pressure Equalising Valves Model 910.25, for Differential Pressure Gauges WIKA Data Sheet AC 09.11 Applications T Isolating, pressure equalising as well as purging and air bleeding valves to

More information

Regulator: Modular Type with Back flow Mechanism. AR30K to 60K. Body size. Port size 1/4 3/8 1/2 3/4 AR40 AR50 3/4 1/2

Regulator: Modular Type with Back flow Mechanism. AR30K to 60K. Body size. Port size 1/4 3/8 1/2 3/4 AR40 AR50 3/4 1/2 Regulator: Modular Type with ack flow Mechanism R3 to 6 How to Order Regulator with a built-in mechanism that ensures a quick release of the outlet air pressure (built-in check valve with back flow mechanism).

More information

Types 1808 and 1808A Pilot-Operated Relief Valves or Backpressure Regulators

Types 1808 and 1808A Pilot-Operated Relief Valves or Backpressure Regulators Types 1808 and 1808A Pilot-Operated Relief Valves or Backpressure Regulators July 2010 W3716 W3507 Type 1808 Type 1808A Figure 1. Types 1808 and 1808A Pilot-Operated Relief Valves or Backpressure Regulators

More information

SPECIFICATIONS. Approximate Weight: 10 oz. Surface Finish: Ra micro inch or less MATERIALS OF CONSTRUCTION

SPECIFICATIONS. Approximate Weight: 10 oz. Surface Finish: Ra micro inch or less MATERIALS OF CONSTRUCTION DIFFUSION-RESISTANT, DIAPHRAGM SEAL, EXCESS FLOW SHUT-OFF VALVES (FS SERIES) FS Series Excess Flow Shut-Off Valves are designed to automatically shut-off the delivery of gas in a line if the flow exceeds

More information

Laboratory Flowmeters

Laboratory Flowmeters Laboratory Flowmeters Wide selection of flow ranges measure air from 0.02 ml/min to 675 LPM or water from 0.0002 ml/min to 20 LPM High-accuracy correlated flowmeters ±2% of reading! Excellent chemical

More information

Series MX pressure regulators 3/

Series MX pressure regulators 3/ CATALOGUE > Release 8.8 > Series MX regulators Series MX pressure regulators MX2 ports: G/8, G1/2, G/4 - MX ports: G/4, G1 Manifold ports: G1/2 (MX2 only) Modular - Available with built-in pressure gauges

More information

Purge Device KPTD/KPTK/KPTH

Purge Device KPTD/KPTK/KPTH Purge Device KPTD/KPTK/KPTH KPTD/KPTK/KPTH 2: principle as shown in figure blow:(invariableness inlet pressure) elasticity membrane have the up power P2A+P1a(1) elasticity membrane have the down power:

More information

Botlek Studiegroep Badotherm. Solving measurements issues with Diaphragm seals 3 Case Studies

Botlek Studiegroep Badotherm. Solving measurements issues with Diaphragm seals 3 Case Studies Botlek Studiegroep 9-4-2015 Badotherm Solving measurements issues with Diaphragm seals 3 Case Studies Prepared: 10/04/2015 Badotherm Company Summary Badotherm introduction Family owned company Founded

More information

Air Saving Valve reduction in 40% air consumption 40% air consumption Air consumption reduction ratio (%) Flow valve Flow valv

Air Saving Valve reduction in 40% air consumption 40% air consumption Air consumption reduction ratio (%) Flow valve Flow valv CAT.ES-173 A Air Saving Valve % reduction in air consumption Cuts air consumption by operating the return stroke at a reduced pressure. valve Pressure Air consumption reduction ratio (%) 3 1.1.1...3 pressure

More information

Pressure reducing valve, direct operated

Pressure reducing valve, direct operated Electric Drives and Controls Table of contents Hydraulics Pressure reducing valve, direct operated Model ZDR 6 D Nominal size 6 Series 4X Maximum operating pressure 20 bar (3050 PSI) Maximum flow 50 L/min

More information

Pressure reducing valve, direct operated, sandwich plate, type ZDR6D...40B/(New Series)

Pressure reducing valve, direct operated, sandwich plate, type ZDR6D...40B/(New Series) Pressure reducing valve, direct operated, sandwich plate, type ZDR6D...40B/(New Series) Huade América 1 BEIJING HUADE HYDRAULIC INDUSTRIAL GROUP CO.,LTD. Pressure reducing valve, direct operated, sandwich

More information

Type 310A-32A Pressure Reducing Regulator and Type 310A-32A-32A Working Monitor Regulator

Type 310A-32A Pressure Reducing Regulator and Type 310A-32A-32A Working Monitor Regulator January 2009 Type 310A-32A Pressure Reducing Regulator and Type 310A-32A-32A Working Monitor Regulator Introduction The Type 310A pilot-operated high-pressure regulator (Figure 1) is used where high capacity

More information

AFC. SDPROC and AFC Analog Mass Flow Controller ANALOG MASS FLOW CONTROLLERS. Principles of Operation. Design Features

AFC. SDPROC and AFC Analog Mass Flow Controller ANALOG MASS FLOW CONTROLLERS. Principles of Operation. Design Features ANALOG MASS FLOW CONTROLLERS Model AF mass fl ow controllers are designed to indicate fl ow rates and control set fl ow rates of gases. Each of these units incorporates an advanced straight tube sensor

More information

61 Series Pilots for Pilot-Operated Pressure Reducing Regulators

61 Series Pilots for Pilot-Operated Pressure Reducing Regulators 61 Series Pilots for Pilot-Operated Pressure Reducing Regulators June 2011 Introduction 61 Series pilots are used with Types 1098-EGR and EZL pressure reducing regulators. These pilots can also be integrally

More information

Power Valve: Precision Regulator. High precision, large capacity relief regulator

Power Valve: Precision Regulator. High precision, large capacity relief regulator Power Valve: Precision Regulator Series VEX High precision, large capacity relief regulator port large exhaust capacity pressure reducing valve which utilizes a nozzle flapper mechanism available as air

More information

PRESSURE REGULATORS AND FLOWMETERS, ALL MEDICAL GASES

PRESSURE REGULATORS AND FLOWMETERS, ALL MEDICAL GASES PRESSURE REGULATORS ALL MEDICAL GASES In this section we propose our pressure regulators (FM series, MU and MERCURY ) and our Rs flowmeters for applications other than oxygen therapy (presented in the

More information

Level MEASUREMENT 1/2016

Level MEASUREMENT 1/2016 Level MEASUREMENT 1/2016 AGENDA 2 A. Introduction B. Float method C. Displacer method D. Hydrostatic pressure method E. Capacitance method G. Ultrasonic method H. Radar method I. Laser method J. Level

More information

HAYWARD FLOW CONTROL Series PBV Back Pressure Valve and Series RPV Pressure Relief Valve INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS

HAYWARD FLOW CONTROL Series PBV Back Pressure Valve and Series RPV Pressure Relief Valve INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS HAYWARD FLOW CONTROL Series PBV Back Pressure Valve and Series RPV Pressure Relief Valve INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS Page 1 of 20 Page 2 of 20 TABLE OF CONTENTS Safety Warnings

More information

Rev. A Jul 07 Part # SS VD510-SS INSTRUCTION MANUAL DISPENSING VALVE MODEL VD510-SS INSTRUCTION MANUAL

Rev. A Jul 07 Part # SS VD510-SS INSTRUCTION MANUAL DISPENSING VALVE MODEL VD510-SS INSTRUCTION MANUAL DISPENSING VALVE MODEL VD510-SS INSTRUCTION MANUAL CONTENTS 1 Introduction page 3 2 Specifications page 3 3 Part Description page 4 4 Operation Principles page 5 5 Operating Procedure page 6 5-1 Setup

More information

Series IRV1000/2000/3000

Series IRV1000/2000/3000 CAT.ES60-16 A Regulator Series /2000/3000 Allows adjustment of vacuum line pressure Regulator Series /2000/3000 3 sizes offered in the series Variations have been expanded to three sizes from only one

More information

3-Way Pressure-Reducing Cartridge, Size 2 4

3-Way Pressure-Reducing Cartridge, Size 2 4 -Way Pressure-Reducing Cartridge, Size 2 Q max = 2 l/min, p max = 25 bar Spool-type design, direct acting, with manual adjustment 1 Description Compact construction for cavity type AM /- UNF to Bucher

More information

G type DUCTED EXHAUST SAFETY VALVE 2871 AND 288X SERIES. Model/Ref:

G type DUCTED EXHAUST SAFETY VALVE 2871 AND 288X SERIES. Model/Ref: Model/Ref: 28713 www.lauridsenindustri.com CHARACTERISTICS The G type safety valves are dedicated to protect the equipment from potential overpressure. They are automatic and close when the pressure conditions

More information

RCD - Ultra-Rugged Differential Pressure Flowmeter

RCD - Ultra-Rugged Differential Pressure Flowmeter 0.15-1 to 85-600 GPM Liquids 2.5-25 to 300-1700 SCFM Gases 1/2 to 3 Line Sizes Bronze or 316-Ti Stainless Steel Mechanical Indicator, Digital Indicator, Transmitters and Switches Available Custom Calibrations

More information

Design Features. General Description

Design Features. General Description Model thermal Mass Flow Controllers are designed to indicate and control set flow rates of gases. The combines the characteristics and accuracy of conventional mass flow devices into a unique compact design

More information

Rev. B Sept 06. VD510 INSTRUCTION MANUAL Part # DISPENSING VALVE MODEL VD510 INSTRUCTION MANUAL

Rev. B Sept 06. VD510 INSTRUCTION MANUAL Part # DISPENSING VALVE MODEL VD510 INSTRUCTION MANUAL DISPENSING VALVE MODEL VD510 INSTRUCTION MANUAL CONTENTS 1 Introduction page 3 2 Specifications page 3 3 Part Description page 4 4 Operation Principles page 5 5 Operating Procedure page 6 5-1 Setup page

More information

ALL-IN-ONE MINI THERMAL MASS FLOWMETER

ALL-IN-ONE MINI THERMAL MASS FLOWMETER INDICATION, TOTAIZATION, -POINT AARM, DC to ma AND PUSE OUTPUT BY ONE UNIT TF-T Series A-IN-ONE MINI TERMA MASS FOWMETER OUTINE TF-T MINI TERMA MASS FOWMETER is for the measurement of mass flow rate of

More information

Self-priming makes priming unnecessary Exhausts the air inside the suction pipe to suck up liquid. Air operated type.

Self-priming makes priming unnecessary Exhausts the air inside the suction pipe to suck up liquid. Air operated type. Process Pump Series 3/5 Automatically Operated Type (Internal Switching Type)/Air Operated Type (External Switching Type) High abrasion resistance and low particle generation o sliding parts in wetted

More information

Vol. IX, No. 8

Vol. IX, No. 8 Vol. IX, No. 8 www.flowcontrolnetwork.com WHEN COST IS A FACTOR Are you going down the right road with a rotameter? T hey re simple and inexpensive, performing as well or better than many high-tech flowmeters

More information

776 Cryogenic Safety Valve

776 Cryogenic Safety Valve 776 Cryogenic Safety Valve INTRODUCTION 776 Cryogenic Safety Valve The effects of exceeding safe pressure levels in an unprotected pressure vessel or system, can have catastrophic effects on both plant

More information

Membrane dryers. Series airfit dry G1/2. with/without patented purge air regulation. Overview Description. Characteristics Dimensions

Membrane dryers. Series airfit dry G1/2. with/without patented purge air regulation. Overview Description. Characteristics Dimensions Overview Description Membrane fitting the airfit comfort series Page Characteristics Dimensions 146 10 11 13 14 Order instructions Type overview Membrane A4P006E-October 2007 14 Membrane Characteristics

More information

Glass Variable Area Flowmeters

Glass Variable Area Flowmeters FLOW Product Data Sheet DS1112 Glass Variable Area Flowmeters GAPMETER TYPES LG/NG Easy to Use, high visibility scale Simple and reliable Gas or Liquid flow measurement Operator confidence from float rotation

More information

Gas Pressure Regulator HON 502

Gas Pressure Regulator HON 502 Gas Pressure Regulator HON 502 Product information serving the gas industry worldwide Gas Pressure regulator HON 502 Application, Characteristics, Technical Data Application for offtake stations in gas

More information

PREX3000 Pneumatic Differential Pressure Transmitter Model KDP

PREX3000 Pneumatic Differential Pressure Transmitter Model KDP OM2-5220-1101 PREX3000 Pneumatic Differential Pressure Transmitter Model KDP User's Manual NOTICE While the information in this manual is presented in good faith and believed to be accurate, Azbil Corporation

More information

MASFLO-OVAL Ⅱ THERMAL MASS FLOWMETER/CONTROL VALVE for GAS MEASUREMENT MODEL: FHC, FHD series

MASFLO-OVAL Ⅱ THERMAL MASS FLOWMETER/CONTROL VALVE for GAS MEASUREMENT MODEL: FHC, FHD series Gas EXPLOSIONPROOF MASFLO-OVAL Ⅱ THERMAL MASS FLOWMETER/CONTROL VALVE for GAS MEASUREMENT MODEL: FHC, FHD series GENERAL SPECIFICATION GS.No.GBF112E 1 GENERAL The explosionproof MASFLO-OVAL Ⅱ FHC series

More information

Gas Proportioners - Back Pressure Compensated

Gas Proportioners - Back Pressure Compensated Gas Proportioners - Back Pressure Compensated G To blend two or three gases in homogeneous infinitely variable concentrations, directly at the end use point, this instrument is unsurpassed in convenience

More information

Pilot HON 630a, HON 640

Pilot HON 630a, HON 640 product information serving the gas industry worldwide pplication, characteristics, technical data pplication pilot for gas pressure regulators HON 0, HON 0, HON 0, HON 0 suitable for natural gas and all

More information

Description Supply pressure Pressure range Connection Device Page max. bar bar thread

Description Supply pressure Pressure range Connection Device Page max. bar bar thread Pressure Regulators Supply pressure Pressure range onnection Device Page max. bar bar thread Maxi -Series, robust, interlockable 1 0. 1.8 / 17 G¼ - G1 R0, R1.0 made of plastic, also for liquids 1,5 0 4

More information

Bubble Tube Installations

Bubble Tube Installations Instruction MI 020-328 September 2013 Bubble Tube Installations For Liquid Level, Density, and Interface Level Measurements 2 Contents Introduction... 5 Abbreviations... 5 Principle of Operation... 5 Alternative

More information

Purgemaster Series 10A6100 SNAP-IN. Instruction Bulletin Replaceable Parts List. D184B003U35 Rev. 01 /

Purgemaster Series 10A6100 SNAP-IN. Instruction Bulletin Replaceable Parts List. D184B003U35 Rev. 01 / SNAP-IN Purgemaster Series 0A600 Instruction Bulletin Replaceable Parts List D84B003U35 Rev. 0 / 03.200 You have purchased a high quality, modern instrument from ABB Automation Products. We thank you for

More information

Self-operated Regulators Accessories Differential Pressure and Flow Regulators

Self-operated Regulators Accessories Differential Pressure and Flow Regulators Self-operated Regulators Accessories Differential Pressure and Flow Regulators Compression-type fittings Needle valves Compensation chambers Orifice plates Welding neck flanges Control lines Application

More information

L21S/SR/ST Glass Level Gauges

L21S/SR/ST Glass Level Gauges L21S/SR/ST Glass Level Gauges Doc. no.: 150, en_cat_l21s/sr/st, 12/2014 Type of code Example: L21ST/1450/AANSI 3/4 150Lb RF/Large chamber Code 1 Basic type L21 2 Type of gauge S Tubular level gauge SR

More information

Series 42 Self-operated Regulators Differential Pressure Regulators with Type 2424/Type 2428 Actuator (closing) Type Type 42-28

Series 42 Self-operated Regulators Differential Pressure Regulators with Type 2424/Type 2428 Actuator (closing) Type Type 42-28 Series 42 Self-operated Regulators Differential Pressure Regulators with Type 2424/Type 2428 Actuator (closing) and balanced Type 2422 Valve Type 42-24 Type 42-28 Application Differential pressure regulators

More information

How to Order RM0 0 Z. IN/OUT fitting type Metric size Inch size Straight Elbow Straight Elbow Straight Elbow Straight Elbow ø ø ø ø ø ø ø ø ø/ ø/ ø/ ø

How to Order RM0 0 Z. IN/OUT fitting type Metric size Inch size Straight Elbow Straight Elbow Straight Elbow Straight Elbow ø ø ø ø ø ø ø ø ø/ ø/ ø/ ø Series RM/ End lock RME Port Plug End block End block type Mounting position L Left side R Right side L side end block 0. L VVQ0000 Single unit regulator / Port plug for regulator block ø0 0 Options Note

More information

Model NDA Differential pressure transmitter. Deltapi N Series A complete range of pneumatic pressure transmitters

Model NDA Differential pressure transmitter. Deltapi N Series A complete range of pneumatic pressure transmitters Data Sheet DS/NDA-EN Rev. H Model NDA Differential pressure transmitter Deltapi N Series A complete range of pneumatic pressure transmitters Introduction The blind type differential pressure transmitter

More information

Rate of Flow Valve Series 120

Rate of Flow Valve Series 120 SPECIFICATIONS Rate of Flow Valve Series DIMENSIONS The OCV Series 120 Rate of Flow control valve is designed to control or limit flow to a predetermined rate, regardless offl uctuations in downstream

More information

THE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401

THE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401 THE MF-400 SERIES Operating and Service Manual Series includes all variants of MF-400/401 Issue A October 2013 1 TABLE OF CONTENTS 1. Description... 3 2. Installation... 3 3. Operation... 4 4. Special

More information

No E. General Information. Averaging Pitot Tube Flow Sensor HITROL CO., LTD.

No E. General Information. Averaging Pitot Tube Flow Sensor HITROL CO., LTD. No. 2000-03E Averaging Pitot Tube Flow Sensor HITROL CO., LTD. M e a s u r e m e n t Pr i n c i p l e Measurement principle of Hitbar sensor is explained below. When a Hitbar is installed in the pipeline

More information

Size 6 up to 31.5MPa 1) up to 25 L/min

Size 6 up to 31.5MPa 1) up to 25 L/min BEIJING HUADE HYDRAULICS INDUSTRIAL GROUP CO.,LTD. 2-way flow control valve Type 2FRM 6 Size 6 up to 31.5MPa 1) up to 25 L/min RC:28160/12.2004 Replaces RC28160/05.2001 Features: - External closing of

More information

Pressure reducing valve, pilot operated

Pressure reducing valve, pilot operated Pressure reducing valve, pilot operated RE 26928/09.07 Replaces: 10.97 1/8 Type 3DR Size 16 Component series 5X Maximum operating pressure 250 bar Maximum flow 220 l/min H5844 Table of contents Content

More information

Leak free Pipe Rupture Valve for Excavators

Leak free Pipe Rupture Valve for Excavators Leak free Pipe Rupture Valve for xcavators Series motion and progress Reference: 3 P 9575 1/11.6 Classification: 43.325.355...325.35 1/17 Contents Page 1 General description................................................................

More information

Air preparation units

Air preparation units Overview Description Page Characteristics Dimensions Order instructions Type overview unit three-piece 44, 45, 48 52 6 unit two piece 44, 45, 48 52 6 Filter-regulator 44, 45, 48 53 6 Filter-water-separator

More information

Regulator for 2 MPa ARX 20. How to Order. Bracket. Pressure gauge. Port size 1/8 1/4. Panel nut

Regulator for 2 MPa ARX 20. How to Order. Bracket. Pressure gauge. Port size 1/8 1/4. Panel nut Regulator for 2 MPa RX 2 How to Order RX2 1 Regulator 1 Regulating pressure.5 to.85mpa {.51 to 8.7kgf/cm²}.5 to.3mpa {.51 to 3.1kgf/cm²} Thread type Nil N F Rc(PT) NPT (PF) Port size 1 2 ccessories/options

More information

Nikuni KTM Series Pumps

Nikuni KTM Series Pumps Nikuni KTM Series Pumps ( Micro Bubble Generator for DAF System ) Client : Project : Model : KTM2N- (SS34 Material) Doc. No. : Date : Revision No. : Japan Headquarters : 843-5, Kuji, Takatsu-Ku, Kawasaki-Shi,

More information

Multiple Tube - Teflon PTFE-Glass Flowmeters

Multiple Tube - Teflon PTFE-Glass Flowmeters Multiple Tube - Teflon PTFE-Glass Flowmeters xt Model xt Multiple Tube Teflon PTFE-Glass Flowmeters combine the convenience of multiple tube meters with the unique design features of single tube Teflon

More information

Versions. Benefits. Balancing DN15-32 DN40 DN50 DN15, DN20, DN25, DN32, DN40, DN50. Dimensions

Versions. Benefits. Balancing DN15-32 DN40 DN50 DN15, DN20, DN25, DN32, DN40, DN50. Dimensions Ballorex Delta Description The Ballorex Delta is a differential pressure control valve used in hydronic heating or cooling systems. By ensuring a constant differential pressure across motorized or static

More information

Instrumentation & Data Acquisition Systems

Instrumentation & Data Acquisition Systems Instrumentation & Data Acquisition Systems Section 3 -Level Robert W. Harrison, PE Bob@TheHarrisonHouse.com Made in USA 1 Level Section Question Which level measuring technology is the best solution when

More information

Variable Area Flow Meters

Variable Area Flow Meters Variable Area Flow Meters Over sixty years of variable area meter expertise Brooks started designing and manufacturing variable area (VA) meters, also referred to as rotameters, in 1946. Now, with more

More information

BDT20 Safety process pressure gauge 100 & 160mm

BDT20 Safety process pressure gauge 100 & 160mm BDT20 Safety process pressure gauge 100 & 160mm Product description Badotherm pressure gauge model BDT20 is the solid front, safety pattern gauge according the highest class of the EN 837-1 / 9.7.2 and

More information

Brooks Flow Controllers for Gas and Liquid Service Model FC 8744, Series FC 8800 and FC 8900

Brooks Flow Controllers for Gas and Liquid Service Model FC 8744, Series FC 8800 and FC 8900 Data Sheet Flow Controllers for Gas and Liquid Service Brooks Flow Controllers for Gas and Liquid Service Model FC 8744, Series FC 8800 and FC 8900 Features and Benefits Flow controllers for high pressure

More information

P3000 Series. Pneumatic Deadweight Testers Model P3000. Technical Data. Features

P3000 Series. Pneumatic Deadweight Testers Model P3000. Technical Data. Features P3000 Series Pneumatic Deadweight Testers P3000 Technical Data Features Pressure ranges from Vacuum through 2 000 psi (140 bar) Accuracy better than 0.015 % of reading. (Increased accuracy option of 0.008

More information

Chlorinator. MODEL C-731 (Floor Mounted)

Chlorinator. MODEL C-731 (Floor Mounted) Chlorinator MODEL C-731 (Floor Mounted) CHLOROTECH Model C-731 is the advance technology Chlorinator designed to feed chlorine gas at a controlled rate. The flow rate of gas is maintained by constant positive

More information

VACUUM REGULATORS CONTENTS

VACUUM REGULATORS CONTENTS CAD drawing data catalog is available. ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS CONTENTS Small Regulators Features 759 Specifications, Order Codes, Flow Rate

More information

Solenoid valves VZWF, force pilot operated

Solenoid valves VZWF, force pilot operated Key features and overview Function Normally closed solenoid valve with diaphragm and forced lifting. When the solenoid is energised, the differential pressure from the secondary side of the diaphragm is

More information

SITRANS P measuring instruments for pressure

SITRANS P measuring instruments for pressure Remote seals for transmitters and pressure gauges Technical description Overview In many cases the pressure transmitter and the measured medium have to be physically separated. It is then necessary to

More information

Smooth Vent Valve. Series XVD XL XL Q D- XVD XGT CYV

Smooth Vent Valve. Series XVD XL XL Q D- XVD XGT CYV Smooth Vent Valve Series Valve / needle valve integrated construction requires only 1/4 the piping space of previous models. Particulates significantly reduced through the use of a metal diaphragm in the

More information

Nikuni KTM Series Pumps

Nikuni KTM Series Pumps Nikuni KTM Series Pumps ( Micro Bubble Generator for DAF System ) Client : Project : Model : KTM5S3- (SS34 material) Date : Doc. No. : Revision No. : Japan Headquarters : 843-5, Kuji, Takatsu-Ku, Kawasaki-Shi,

More information

R S 280 is a modular parallel sect. Directional Control Valve RS RS In relation to its flow capacity its installation

R S 280 is a modular parallel sect. Directional Control Valve RS RS In relation to its flow capacity its installation Directional Control Valve RS 280 3 RS 2802 3102RS28001 R S 280 is a modular parallel sect nal valve. Suitable applications are medium sized and big truck loaders, medium sized backhoe loaders and other

More information

CHECK VALVES APPLICATIONS

CHECK VALVES APPLICATIONS 45 APPLICATIONS The check valves, shown in this chapter, are classified Pressure accessories in the sense of the Pressure Equipment Directive 97//EC, Article 1, Section 2.1.4 and are subject of Article

More information

Auto Feed Lube, Auto Feed Tank ALF400 to 900, ALT-5/-9

Auto Feed Lube, Auto Feed Tank ALF400 to 900, ALT-5/-9 Auto Feed Lube, Auto Feed Tank 00 to 900, -/-9 Standard Specifications Fluid Proof pressure Operating pressure differential range (Difference between tank pressure and line pressure) Vibration resistance

More information

Specifications. Construction. 2 port valve/series VHK2 3 port valve/series VHK3. Component Parts. Standard style. Flame resistant style

Specifications. Construction. 2 port valve/series VHK2 3 port valve/series VHK3. Component Parts. Standard style. Flame resistant style Finger Valve SeriesVHK Large effective area: to mm 2 Small knob operating force: 0.43 to 1.4 kgfcm Poppet valve construction with few seal defects The series begins with the min. tube O.D. of. Selection

More information

Gas Pressure Regulator HON 505

Gas Pressure Regulator HON 505 product information serving the gas industry worldwide Application, Characteristics, Technical Data Application for gas supply for natural gas and all non-corrosive gaseous media Characteristics compact

More information

Nikuni KTM Series Pumps

Nikuni KTM Series Pumps Nikuni KTM Series Pumps ( Micro Bubble Generator for DAF System ) Client : Project : Model : KTM25FD7ZM- (Cast Iron Material) Date : Doc. No. : Revision No. : Japan Headquarters : 843-5, Kuji, Takatsu-Ku,

More information

GAS PRESSURE REGULATORS AP

GAS PRESSURE REGULATORS AP A Long Experience in Energy Equipment and one Goal: The Customer s satisfaction. GAS PRESSURE REGULATORS AP (High Pressure) ALPHARD P/AP Pressure Regulator Applications It is designed for use in transmission

More information

Differential pressure

Differential pressure Differential pressure 9 Overview Page 200 VEGADIF 65 Page 202 Chemical seal Page 204 Accessory Page 208 199 VEGADIF For differential pressure, level and flow measurements Measuring principle The sensor

More information

Pressure reducing valve, direct operated

Pressure reducing valve, direct operated Electric Drives and Controls Table of contents Hydraulics Pressure reducing valve, direct operated Model DR 10 DP Nominal size 10 Series 4X Maximum reduced pressure 210 bar (3050 PSI) Maximum flow 80 L/min

More information

Air Saving Valve. Pressure Valve Flow Valve

Air Saving Valve. Pressure Valve Flow Valve Air Saving Valve Series Series Pressure Valve Flow Valve % reduction in air consumption Cuts air consumption by operating the return stroke at a reduced pressure. valve Pressure Air consumption reduction

More information

Combined Pressure / Vacuum Relief Valve KITO VD/o

Combined Pressure / Vacuum Relief Valve KITO VD/o KITO VD/o DN D H kg* vacuum setting (mbar) pressure DIN ANSI DIN ANSI min max min max** 50 PN 16 2 220 332 351 11 3 50 10 75 80 PN 16 3 260 367 387 145 3 50 10 70 100 PN 16 4 260 368 393 178 3 50 10 80

More information

Brooks Flow Controllers for Gas and Liquid Service Model FC 8744, Series FC 8800 and 8900

Brooks Flow Controllers for Gas and Liquid Service Model FC 8744, Series FC 8800 and 8900 Data Sheet Flow Controllers for Gas and Liquid Service Brooks Flow Controllers for Gas and Liquid Service Model FC 8744, Series FC 8800 and 8900 Model FC 8800 Flow Controller Model 1350/55 with FC 8900

More information

Calibrated or locked versions available. TREATMENT > Series MD regulators GENERAL DATA. New

Calibrated or locked versions available. TREATMENT > Series MD regulators GENERAL DATA. New > Series MD regulators Series MD pressure regulators New Ports with interchangeable cartridges: threaded (1/8, 1/4, /8) or integrated with super-rapid fitting for tube with Ø 6, 8 and 10 mm Versions: single,

More information

Pilot Check Valve: Metal Body Type

Pilot Check Valve: Metal Body Type INFORMATION Pilot Check Valve: Metal Body Type The use of a metal body improves strength and environmental resistance. Temporary intermediate stops are possible. *1 *1 Precise intermediate stops are not

More information