Safety Aspects and Design of the Vent Isolation Chamber. Prepared: W.M. Snow Checked: H. Nann Approved: W. M. Snow

Size: px
Start display at page:

Download "Safety Aspects and Design of the Vent Isolation Chamber. Prepared: W.M. Snow Checked: H. Nann Approved: W. M. Snow"

Transcription

1 Safety Aspects and Design of the Vent Isolation Chamber Prepared: W.M. Snow Checked: H. Nann Approved: W. M. Snow 1. Scope This document addresses the safety aspects and design of the vent isolation chamber which is part of the safety hydrogen relief system of the NPDGamma liquid hydrogen target. 2. Components covered The documents cover the vent isolation chamber up to its input flanges and relief devices inside the chamber, see Fig. 1. The dimensional calculations for the fill/vent line between the hydrogen vessel/cryostat and the vent isolation chamber are given in document Designreliefvent.doc. In this document we describe the strength calculations for the vent isolation chamber and how the relief devices have been sized. 2. Arrangement The purpose of the vent isolation chamber is to couple the hydrogen vessel and isolation vacuum lines to the single line vent stack through the relief and rupture disks. The vent isolation chamber contains a large relief valve of the hydrogen vessel and three rupture disks. The rupture disks are the primary safety devices used to achieve Code compliance for the high mass flow accident scenario situation. The safety plan assumes that the rupture disks will open only when there is a catastrophic failure of the isolation vacuum or rupture of the hydrogen vessel. The second disk in parallel configuration on the isolation vacuum is for additional redundancy. In addition to these two rupture disks is a parallel small throughput spring-loaded relief valve, RV201, with opening pressure of 3 psid which is designed to vent small amount of gas from the isolation vacuum into vent stack to protect the isolation vacuum rupture disks from unnecessary rupture. During a long target run a small amount of degassed gas can be condensed to the cold surfaces in the cryostat and during a warmup the pressure in the isolation vacuum could raise over the pressure outside the cryostat and needs to be relieved. Note that the replacement of the broken rupture disks in the vent isolation chamber requires a major effort. The vent isolation chamber contains the relief valves and rupture disks for the hydrogen vessel and the isolation vacuum chamber. The 1.5 in diameter hydrogen line and the 6 in diameter vacuum line are installed coaxially. This coaxial line is called the fill/vent line and it runs from the target cryostat to the vent isolation chamber where the two lines are separately connected to the inlets of the vent isolation chamber, see Fig. 1. The outlet of the vent isolation chamber is connected to the vent stack. The chamber is mounted inside of a vent isolation

2 cabinet along with valves and other components of the gas handling system. All the demountable joints are made from CF flanges with copper gaskets and the bolts of the joints are tightened to the recommended torque by manufacturer. Coxial fill/vent line From isolation vacuum Vent isolation chamber Hydrogen line Fig. 1 The model view of the vent isolation chamber inside the ventilated vent isolation cabinet when the cabinet cover has been removed Inside the vent isolation chamber (a cut view is shown in Fig. 2) are the pressure relief devices for the LH 2 target vessel; relief valve RV104 (set point: 20 psid) and in parallel burst disk RD101 (set point: 30 psid), and the burst disks for the isolation vacuum, RD201 (set point: 7 psid) and in parallel RD202 (set point: 7 psid). Parallel with these rupture disks is also the low throughput relief valve, RV201 with a setpoint of 3 psid. RV201 is not connected to the vent isolation chamber but to the vent stack.

3 Fig. 2. A cut view of the vent isolation chamber showing the relief valve, RV104 and rupture disks, RD101, RD201, and RD202. The vent isolation chamber is a cylindrical vessel, constructed of 10-inch, Schedule 10 NPS stainless steel pipe of thickness inch, with flanged, flat Conflat heads on either end. It is 28 inches long. The inlet to the vent isolation chamber is the 1.5-inch pipe from the LH 2 target vessel through a flanged head. The flanged outlet at the other end is for the 6.0-inch diameter vent stack which conducts the relieved hydrogen to outside of the Target Building. The thickness of the two end flanges is inch. The end of the large relief valve RV104 is stabilized against transverse motion relative to the chamber axis by a spider alignment fixture see attached drawing Additionally, there are two 10-inch full inlet joints on the side of the cylindrical shell, which are connected to the target isolation vacuum chamber. Lifting lugs are provided for motion and positioning. The design drawings of the vent isolation chamber are in attached set of drawings # S trength Calculation of the Vent Isolation Chamber The following calculations were performed to evaluate the mechanical strength of the designed vent isolation chamber. The cylindrical part has a length of L = 28 inch, a diameter of D 0 =10.75 inch, and a wall thickness of t = inch (10-inch NPS, Sch. 10S). Thus L/D 0 = 2.60 and D 0 /t = The thickness of the flat end heads is inch. The required minimum wall thickness of the straight pipe according to Paragraph of ASME B31.3 for an internal pressure of p = 150 psi is

4 ( SE + py) 150( 10.75) [ 20000( 1) + 150( 0.4) ] pd0 tmin = = = < inch 2 2 The required thickness for the flat heads on either end is according to UG-34 of ASME VIII, Div.1.: ( 0.33) 150 ( ) Cp t req = d = = < inch SE In summary, the maximum internal pressure in the vent isolation chamber is defined by the mass flow and the flow impedance of the vent stack. The calculated maximum pressure in the vent isolation chamber during the worst possible incident is 4 psig, which is significantly below the 150 psi used in the calculations. 4. S pecifications for R elief Valves and R upture Dis ks 4.1 H 2 vessel relief valve The specifications for the LH 2 vessel relief valve, RV104 are: 1. vacuum tight to the level of 10-9 bar cc/s, allowing the LH 2 vessel to be evacuated for leak checking and held evacuated without leakage. 2. no leakage under pressure up to 85% of the set pressure. 3. withstand the maximum operating pressure of 32 psia and the maximum allowed working pressure of 40 psia 4. handle the mass flow under an accident scenario In choosing the LH 2 target vessel relief valve, RV104, we assume that the mass flow (maximum H 2 mass flow rate = lb/s) is caused by loss of the isolation vacuum. The pressure difference through the 1.5 fill/vent line up to the relief valve is 21.7 psid for a resistance coefficient of K = 40. The calculations behind this estimate can be found in the document Designreliefvent.doc. The H 2 relief valve, RV104, is an Anderson Greenwood (AG) direct-acting spring valve model 83 with a J orifice (1.287 in 2 flow area) and a 20 psig set pressure. The ASME rated mass flow capacity at set pressure is lb/s which is larger than the assumed maximum H 2 flow rate of lb/s. 4.2 H 2 vessel rupture disk The specifications for the LH 2 vessel rupture disk RD101 are: 1. vacuum tight to the level of 10-9 bar cc/s, allowing the LH 2 vessel to be evacuated for leak checking and held evacuated without leakage. 2. no diffusion of gas from the vent isolation box into the main vacuum 3. withstand the maximum operating pressure of 32 psia and the

5 maximum allowed working pressure of 40 psia 4. handle the mass flow under an accident scenario We use Fike Corporation model SR-H rupture disks that have a molded-on gasket and fit Tri-Clover flanges. A 2 diameter rupture disk model 2 SRL/Ni/50#/72F/STD with SRL-GI/150#/CS/CS holder with range of +0 10% was chosen. The pressure set point is 30 psid, which is greater than the RV104 relief valve set point of 7 psid. The Fike catalog gives a flow resistance coefficient K =1.88 for a ruptured SR-H disk which indicates a rather free opening after the rupture of the disk. To satisfy the requirement #2 we designed a double o-ring seal for the rupture disk flange which did not require any modification of the disk mechanical structure and therefore preserves the integrity of the manufacturer s pressure rating. In the inner grove we use indium wire to prevent diffusion of gas to isolation vacuum. Fig. 20. Design of the double seals for the rupture disks. For details see drawing SNEUT-Y Main Vent Assy.pdf, available on web page The design incorporates an indium groove inside of the viton o-ring groove so that there is no diffusion of gas from the relief pipe into the isolation vacuum. This design produces no mechanical modification to the burst disks themselves which are certified by the manufacturer. 4.3 Vacuum rupture disks

6 Specifications for rupture disks RD201 and RD202: 1. Must be vacuum tight to the level of 10-9 bar cc/s. 2. Pressures: a. Normal operation = vacuum b. Vacuum chamber design pressure = 32 psia c. Maximum allowable working pressure = 29 psig d. Pressure set points = 7 psid and 7 psid. We chose the Fike model 4 SRL/Ni/30#/72f/std rupture disks with pressure tolerance of 0 10% and burst pressures of 7 psid. The holder is 4 SRX- GI/150#/CS/CS. 4.4 Vacuum relief valve Specifications for the small relief valve, RV201: 1. Must be vacuum tight to the level of 10-9 bar cc/s, which is a low enough leakage rates that vacuum chamber can be isolated from pump system for weeks. 2. Essentially no leakage under pressure up to 85% of set pressure 3. Pressures: a. Normal operation = vacuum b. Vacuum chamber design pressure = 32 psia c. Maximum allowable working pressure = 29 psid d. Pressure set point = 3 psid We chose Swagelok valve SS-4CA-VCR-50 for this small relief valve. Backpressure on Rupture Disks RD201 and RD202 In the case of a failure of the two refrigerators (e.g. power failure) with no vacuum failure the LH 2 target vessel will slowly warm up causing the liquid hydrogen to boil off. This will cause a slow pressure increase in the 1.5-inch relief line up the pressure relief valve RV104, situated in the vent isolation box, till RV104 opens at its set pressure of 20 psid. Then hydrogen gas will flow into the vent isolation box causing a pressure increase in the box. Assuming a normal atmospheric pressure of 14.7 psi at Oak Ridge, then the maximum pressure in the vent isolation box is 14.7 psi with respect to vacuum, provided that the gas flow into the vent isolation box is not larger than the gas flow out of the box into the atmosphere.

Design and Safety Document for the Vacuum Windows of the NPDGamma Liquid Hydrogen Target at SNS

Design and Safety Document for the Vacuum Windows of the NPDGamma Liquid Hydrogen Target at SNS Design and Safety Document for the Vacuum Windows of the NPDGamma Liquid Hydrogen Target at SNS Prepared: Checked: Approved: H. Nann W. Fox M. Snow The NPDGamma experiment is going to run at BL13 at SNS

More information

FAILURE AND HAZARD ANALYSIS OF THE NPDGAMMA LH2 TARGET SYSTEM

FAILURE AND HAZARD ANALYSIS OF THE NPDGAMMA LH2 TARGET SYSTEM FAILURE AND HAZARD ANALYSIS OF THE NPDGAMMA LH2 TARGET SYSTEM Revision: 0.00 Edited by: Seppo Penttila, November 10, 2010 1. General The RSS 8305.0 Installation, Commissioning, and Operation of the NPDGamma

More information

D R A F T. Operating Procedures for the NPDGamma Liquid Hydrogen Target at the BL 13. Version 1.00

D R A F T. Operating Procedures for the NPDGamma Liquid Hydrogen Target at the BL 13. Version 1.00 D R A F T Operating Procedures for the NPDGamma Liquid Hydrogen Target at the BL 13 Version 1.00 October 06, 2010 Operating Procedures for the NPDGamma Liquid Hydrogen Target V1.00 6/10/10 2 Table of Content

More information

DRAFT. Operating Procedures for the NPDGamma Liquid Hydrogen Target in TA-53, Building MPF-35

DRAFT. Operating Procedures for the NPDGamma Liquid Hydrogen Target in TA-53, Building MPF-35 Operating Procedures for the NPDGamma Liquid Hydrogen Target V0.03 11/26/05 1 DRAFT Operating Procedures for the NPDGamma Liquid Hydrogen Target in TA-53, Building MPF-35 Version 0.03 November 26, 2005

More information

SNS BL-13B NPDGamma Experiment

SNS BL-13B NPDGamma Experiment SNS BL-13B NPDGamma Experiment Hydrogen Supply to Cryogenic Target, Relief and Vent System Design Review April 7, 2010 C-156 9:00 10:30 PM Hydrogen System Block Diagram Diagram of Major System Components

More information

Hall C SHMS Q2, Q3, and Dipole: Magnet Pressure Safety. Eric Sun. October 12, Experiment Readiness Review of Physics Division.

Hall C SHMS Q2, Q3, and Dipole: Magnet Pressure Safety. Eric Sun. October 12, Experiment Readiness Review of Physics Division. Hall C SHMS Q2, Q3, and Dipole: Magnet Pressure Safety Eric Sun 1 Outline Cryogenic Control Reservoir Relief Valves Rupture Discs Parallel Relief Plates Independent Sizing Calculation Pressure Safety of

More information

6.6 Relief Devices. Introduction

6.6 Relief Devices. Introduction 6.6 Relief Devices Introduction Relief devices are used to help prevent a catastrophic failure of equipment and/or minimize the effects of any unanticipated or uncontrolled events. As such, relief devices

More information

Challenges in Relief Design for Pilot Plants

Challenges in Relief Design for Pilot Plants Challenges in Relief Design for Pilot Plants Published on July 5, 2017 Michael Trainor Relief system design at the pilot scale presents unique challenges that don t always apply at the commercial scale.

More information

GREIG FILTERS, INC. OPERATION MANUAL

GREIG FILTERS, INC. OPERATION MANUAL GREIG FILTERS, INC. OPERATION MANUAL MODEL DCFH 3P 15/3 100 S4 DOE/222 DUAL CARTRIDGE FILTER HOUSING TABLE OF CONTENTS I. INTRODUCTION II. CARTRIDGE FILTER HOUSING UNIT A. OPERATION B. INSTALLATION C.

More information

Tank Blanketing Pressure Regulators RHPS Series

Tank Blanketing Pressure Regulators RHPS Series www.swagelok.com Tank Blanketing Pressure Regulators RHPS Series Types: pressure reducing and vapor recovery 16L stainless steel construction 1/2, 1, and 2 in. end connections Working pressures up to 22

More information

DUPLEX TECHNICAL INFORMATION FABRICATED DUPLEX STRAINERS

DUPLEX TECHNICAL INFORMATION FABRICATED DUPLEX STRAINERS DUPLEX STRAINER TECHNICAL INFORMATION - 119 - SCREEN OPENINGS 100 Mesh - 30% O.A. 0.006 Openings 80 Mesh - 36% O.A. 0.008 Openings 60 Mesh - 38% O.A. 0.010 Openings 40 Mesh - 41% O.A. 0.016 Openings 30

More information

776 Cryogenic Safety Valve

776 Cryogenic Safety Valve 776 Cryogenic Safety Valve INTRODUCTION 776 Cryogenic Safety Valve The effects of exceeding safe pressure levels in an unprotected pressure vessel or system, can have catastrophic effects on both plant

More information

RCS Rupture Disc Assembly

RCS Rupture Disc Assembly RCS Rupture Disc Assembly 3-2225-3 The RCS Rupture Disc is a reverse acting, cross-scored rupture disc. It is a non-reclosing differential pressure relief device that provides instantaneous full opening

More information

What is pressure relief valve? Pressure relief valve

What is pressure relief valve? Pressure relief valve What is pressure relief valve? Pressure relief valve What is: Relief valve Safety valve Safety relief valve Type of pressure relief valve Pressure relief valve sizing base What are the sizing basis of

More information

Si C132. Safety valves for pressure relief in accordance to PED, DIN/EN and ASME. Engineering GREAT Solutions

Si C132. Safety valves for pressure relief in accordance to PED, DIN/EN and ASME. Engineering GREAT Solutions Safety valves for pressure relief in accordance to PED, DIN/EN and ASME Engineering GREAT Solutions Si C132 Features The universal compact safety valve > 3 body seat sizes for appropriate size selection

More information

Changes Between API STD 520 Part II 6th Ed and 5th Ed Cataloged

Changes Between API STD 520 Part II 6th Ed and 5th Ed Cataloged Changes Between API STD 520 Part II 6th Ed and 5th Ed Cataloged Dustin Smith Smith & Burgess LLC 7600 W Tidwell, Houston, TX Dustin.Smith@smithburgess.com John Burgess Jessye Palladino Smith & Burgess

More information

S300 Series. Valve Link. Features. Fisher Controls

S300 Series. Valve Link. Features. Fisher Controls S0 Series Self-Operated Type VL FIELDVUE Regulators Valve Link Fisher Controls May 198 Bulletin 71.1:S0 The S0 Series self-operated, spring-loaded regulators are used for pressure-reducing control in a

More information

WATER MADE EASY MARINE ENERGY MUNICIPAL INDUSTRIAL

WATER MADE EASY MARINE ENERGY MUNICIPAL INDUSTRIAL Capital Controls Series 71V3000 The Series 71V3000 electrically-heated vaporizer automatically vaporizes and superheats liquid chlorine, sulfur dioxide or ammonia at a rate controlled by the gas feed system.

More information

Installation Operation Maintenance

Installation Operation Maintenance 682 Seal Cooler New generation seal cooler to meet and exceed the seal cooler requirements stated in the 4th Edition of API Standard 682 Installation Operation Maintenance Experience In Motion Description

More information

SCA Series Inverted Bucket Steam Traps

SCA Series Inverted Bucket Steam Traps 0770050/5 IM-P077-06 ST Issue 5 SCA Series Inverted Bucket Steam Traps Installation and Maintenance Instructions 1. General safety information 2. General product information 3. Installation 4. Commissioning

More information

Single & Headered Relief Vent Piping Analysis

Single & Headered Relief Vent Piping Analysis Single & Headered Relief Vent Piping Analysis Todd Jekel, Ph.D., P.E. Industrial Refrigeration Consortium 2005 Research & Technology Forum January 21, 2005 Madison, WI 1 Purpose Vent piping requirements

More information

Mooney * Noise Controller Installation, Operation, and Maintenance Manual

Mooney * Noise Controller Installation, Operation, and Maintenance Manual GE Oil & Gas Mooney * Noise Controller Installation, Operation, and Maintenance Manual imagination at work Scope This manual provides instructions for installation, operation and maintenance of the Mooney

More information

UBP32 Sealed Balanced Pressure Thermostatic Steam Trap for use with PC_ Pipeline Connectors Installation and Maintenance Instructions

UBP32 Sealed Balanced Pressure Thermostatic Steam Trap for use with PC_ Pipeline Connectors Installation and Maintenance Instructions 1270750/7 IM-P127-02 ST Issue 7 UBP32 Sealed Balanced Pressure Thermostatic Steam Trap for use with PC_ Pipeline Connectors Installation and Maintenance Instructions 1 General safety information 2 General

More information

Model MTB-ASME Horizontal Bladder Tanks

Model MTB-ASME Horizontal Bladder Tanks DATA SHEET Model MTB-ASME Horizontal Bladder Tanks Features n UL Listed and FM Approved for use with various proportioners and foam concentrates n 175 psi (12.1 bar) maximum allowable working pressure

More information

Cash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified

Cash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified Cash Valve PILOT OPERATED BACK PRESSURE VALVE ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 01 Certified KP HIGH CAPACITY PILOT OPERATED BACK PRESSURE VALVE DESCRIPTION The Cash Valve Type KP is a pilot

More information

NPDGAMMA LIQUID HYDROGEN TARGET ENGINEERING DOCUMENT. Version 1.0

NPDGAMMA LIQUID HYDROGEN TARGET ENGINEERING DOCUMENT. Version 1.0 NPDGAMMA LIQUID HYDROGEN TARGET ENGINEERING DOCUMENT Version 1.0 December 02, 2004 NPDGamma Liquid Hydrogen Target Engineering Document Contributers: IUCF: H. Nann, M. Snow, W. Fox, B. Lozowski, J. Vanderwerp,

More information

USM21 Sealed Bimetallic Steam Trap for use with Pipeline Connectors Installation and Maintenance Instructions

USM21 Sealed Bimetallic Steam Trap for use with Pipeline Connectors Installation and Maintenance Instructions 6250250/1 IM-P625-03 ST Issue 1 USM21 Sealed Bimetallic Steam Trap for use with Pipeline Connectors Installation and Maintenance Instructions 1. General safety information 2. General product information

More information

Installation Instructions For Flat Seated Bolted Type RAH Series Disk Holders

Installation Instructions For Flat Seated Bolted Type RAH Series Disk Holders Installation Instructions For Flat Seated Bolted Type RAH Series Disk Holders RA Series Rupture Disks 1. WARNING a) Read the complete instructions before attempting to install the rupture disk and holder

More information

2.0 INSTALLATION & SERVICE

2.0 INSTALLATION & SERVICE Installation, Operation, and Maintenance Instructions MODEL 5600 / 5600R January 2005 CONTENTS 1.0 GENERAL 1.1 5600 Model Number Information -----------------------------------------------------------------------

More information

PRO-50 Instrument Supply Regulator

PRO-50 Instrument Supply Regulator Features CRN Approved The PRO-50 Regulator has been granted a Canadian Registration Number. Sour Service Capability Available in NACE configurations that comply with NACE MR0175/MR0103. Environmental limits

More information

627 Series Pressure Reducing Regulators

627 Series Pressure Reducing Regulators 627 Series Pressure Reducing Regulators Introduction The 627 Series direct-operated pressure reducing regulators (Figure 1) are for low and high-pressure systems. These regulators can be used with natural

More information

299H Series. Introduction. P.E.D. Categories. Specifications. Installation. Warning. Installation Guide English September 2012

299H Series. Introduction. P.E.D. Categories. Specifications. Installation. Warning. Installation Guide English September 2012 Installation Guide English September 2012 299H Series Introduction This Installation Guide provides instructions for installation, startup, and adjustment of 299H Series regulators. To receive a copy of

More information

ANDERSON GREENWOOD SERIES 9000 POSRV INSTALLATION AND MAINTENANCE INSTRUCTIONS

ANDERSON GREENWOOD SERIES 9000 POSRV INSTALLATION AND MAINTENANCE INSTRUCTIONS Procedure-assembly-functional test and performance requirements 1 SCOPE 1.1 This document establishes the general procedure for assembly, functional testing and normal performance requirements of low Series

More information

NPDGamma LH2 Target OJT Lesson Plan: Senior Operator for the NPDGamma LH2 Target Operators

NPDGamma LH2 Target OJT Lesson Plan: Senior Operator for the NPDGamma LH2 Target Operators 0. Introduction Object of this on-the-job Training (OJT) Lesson Plan is to train Senior Operators for the NPDGamma LH2 target system. After successful of this OJT and authorization by line management Senior

More information

SPECIFICATIONS. Approximate Weight: 10 oz. Surface Finish: Ra micro inch or less MATERIALS OF CONSTRUCTION

SPECIFICATIONS. Approximate Weight: 10 oz. Surface Finish: Ra micro inch or less MATERIALS OF CONSTRUCTION DIFFUSION-RESISTANT, DIAPHRAGM SEAL, EXCESS FLOW SHUT-OFF VALVES (FS SERIES) FS Series Excess Flow Shut-Off Valves are designed to automatically shut-off the delivery of gas in a line if the flow exceeds

More information

American Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM

American Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM American Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM ASSE STANDARD #1019 - REVISED: 2011 Wall Hydrant with Backflow Protection and Freeze Resistance MANUFACTURER: CONTACT PERSON: E-MAIL:

More information

Horizontal Bladder Tanks

Horizontal Bladder Tanks DATA SHEET Horizontal Bladder Tanks Features UL Listed and FM Approved for use with various ANSUL proportioners and foam concentrates 175 psi (12.1 bar) maximum allowable working pressure (design pressure)

More information

Model MTB-ASME Vertical Bladder Tanks

Model MTB-ASME Vertical Bladder Tanks DATA SHEET Model MTB-ASME Vertical Bladder Tanks Features n UL Listed for use with various proportioners and foam concentrates n 175 psi (12.1 bar) maximum allowable working pressure (design pressure)

More information

Vertical Bladder Tanks

Vertical Bladder Tanks DATA SHEET Vertical Bladder Tanks Features UL Listed and FM Approved for use with various ANSUL proportioners and foam concentrates 175 psi (12.1 bar) maximum allowable working pressure (design pressure)

More information

The Vac-Saf. System. BSBsystems.com BSB.ie Visit our website for the most complete, up-to-date information

The Vac-Saf. System. BSBsystems.com BSB.ie Visit our website for the most complete, up-to-date information The Vac-Saf System Two-Way Pressure Relief (Vacuum and Overpressure) High Pressure Relief Direction Low Pressure Relief Direction Shown: Type HiLo Two-Way Relief Rupture Disk and Safety Head BSBsystems.com

More information

COMMITTEE DRAFT. API 520 Part I 10 th Edition Ballot Item 2.1. This ballot covers the following item:

COMMITTEE DRAFT. API 520 Part I 10 th Edition Ballot Item 2.1. This ballot covers the following item: This ballot covers the following item: API 520 Part I 10 th Edition Ballot Item 2.1 2008 12 Modify guidance to PRV datasheets (Line 17) to assist user s with determining the temperature to use for selecting

More information

299H Series Pressure Reducing Regulators

299H Series Pressure Reducing Regulators September 12 299H Series Pressure Reducing Regulators Inlet Pressure up to psig / 1 bar Compact ±1% Accuracy for Fixed Factor Billing (PFM) Rugged Construction Integral Pilot Easy to Maintain W713 Figure

More information

EASTERN ENERGY SERVICES PTE LTD. 60 Kaki Bukit Place #02-19 Eunos Tech Park Singapore, SG Singapore Telephone: Fax:

EASTERN ENERGY SERVICES PTE LTD. 60 Kaki Bukit Place #02-19 Eunos Tech Park Singapore, SG Singapore Telephone: Fax: 2 Table Of Contents 1. Introduction 3 2. About this Manual 3 3. Contacting YZ Systems 3 4. Vessel Components 4 5. Specifications 5 6. Application 6 7. Theory of Operation 7 8. DuraSite Installation & Use

More information

Types 627W and 627WH Direct-Operated Pressure Reducing Liquid Regulators

Types 627W and 627WH Direct-Operated Pressure Reducing Liquid Regulators Types 627W and 627WH Direct-Operated Pressure Reducing Liquid Regulators Introduction The Types 627W and 627WH are direct-operated pressure reducing regulators for liquid service. They are available in

More information

ENGINEERING TECHNICAL REPORT

ENGINEERING TECHNICAL REPORT SSP DUOLOK FITTINGS ON 1.000 x 0.139 WALL 316SS TUBING ENGINEERING TECHNICAL REPORT SSP 8250 Boyle Parkway Twinsburg, Ohio 44087 U.S.A. mysspusa.com 1.330.425.4250 1 TABLE OF CONTENTS 1.0 Introduction

More information

The Shand & Jurs Model Vapor Guard Tank Blanketing Valve

The Shand & Jurs Model Vapor Guard Tank Blanketing Valve Lower maintenance due to fewer parts Occupies less space, less stress to tank Teflon is inert to most chemicals; extends service life Simplifies and lowers maintenance cost Optimizes flow of blanketing

More information

756 Safety Relief Valves

756 Safety Relief Valves 756 S a fe t y R e l i e f Va l ve s INTRODUCTION 756 Safety Relief Valves The effects of exceeding safe pressure levels in an unprotected pressure vessel or system, can have catastrophic effects on both

More information

Title: Pressure Relieving and Venting Devices Function: Ecology & Safety No.: BC Page: 1 of 7 Reviewed: 6/30/12 Effective: 7/1/12 (Rev.

Title: Pressure Relieving and Venting Devices Function: Ecology & Safety No.: BC Page: 1 of 7 Reviewed: 6/30/12 Effective: 7/1/12 (Rev. Preparer: Team Member, North America, Process Safety Center of Expertise No.: BC032.020 Page: 1 of 7 Owner: Manager, North America Process Safety Center of Expertise Approver: Sr. Vice President, Ecology

More information

Best Practices for Installation of Gaseous Sample Pumps

Best Practices for Installation of Gaseous Sample Pumps Best Practices for Installation of Gaseous Sample Pumps Goal of the Gas Sample Pump Transport a clean, reliable, sample of the process gas to the analyzer, in the safest and easiest way possible, to ensure

More information

Model MTB-ASME Vertical Bladder Tanks

Model MTB-ASME Vertical Bladder Tanks DATA SHEET Model MTB-ASME Vertical Bladder Tanks Features n UL Listed for use with various proportioners and foam concentrates n 175 psi (12.1 bar) maximum allowable working pressure (design pressure)

More information

Type S301 & S302 Gas Regulators INTRODUCTION INSTALLATION. Scope of Manual. Description. Specifications. Type S301 and S302. Instruction Manual

Type S301 & S302 Gas Regulators INTRODUCTION INSTALLATION. Scope of Manual. Description. Specifications. Type S301 and S302. Instruction Manual Fisher Controls Instruction Manual Type S301 & S302 Gas Regulators October 1981 Form 5180 WARNING Fisher regulators must be installed, operated, and maintained in accordance with federal, state, and local

More information

MSC Guidelines for Pressure Vessels

MSC Guidelines for Pressure Vessels References: a. 46 CFR Part 54 Pressure Vessels S. T. Brady, CDR, Chief, Engineering Division b. ASME Boiler and Pressure Vessel Code (BPVC), Section VIII, Division 1, (1998 Edition) c. Navigation and Inspection

More information

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS IAPMO GUIDE CRITERIA FOR WATER HEATER SUPPLY SHUTOFF VALVE WITH A / THERMAL EXPANSION CONTROL VALVE IGC 128-2006a8 1. PURPOSE 1.1 The purpose

More information

IAPMO GUIDE CRITERIA FOR BALL VALVES IAPMO IGC PURPOSE

IAPMO GUIDE CRITERIA FOR BALL VALVES IAPMO IGC PURPOSE INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS IAPMO GUIDE CRITERIA FOR BALL VALVES IAPMO IGC 157-20067 1 PURPOSE 1.1 The purpose of this standard is to establish an acceptable standard

More information

Anderson Greenwood Series 93 Positive Pressure POSRV Installation and Maintenance Instructions

Anderson Greenwood Series 93 Positive Pressure POSRV Installation and Maintenance Instructions Before installation these instructions must be fully read and understood Installation and maintenance instructions for Series 93 Positive Pressure Pilot Operated Safety Relief Valves (POSRV). The intent

More information

Gas Lines. Technical Manual. Sumitomo (SHI) Cryogenics of America, Inc Vultee Street Allentown, PA U.S.A.

Gas Lines. Technical Manual. Sumitomo (SHI) Cryogenics of America, Inc Vultee Street Allentown, PA U.S.A. Gas Lines Technical Manual Sumitomo (SHI) Cryogenics of America, Inc. 1833 Vultee Street Allentown, PA 18103-4783 U.S.A. Revision F: April 2008 261320A TABLE OF CONTENTS Page DESCRIPTION...1 SPECIFICATIONS...2

More information

Vibration/leak Test 2.5 and 6 Vatterfly Valves (3179 and 3223) spare units. GP-B Engineering Procedure P0761 Rev.-

Vibration/leak Test 2.5 and 6 Vatterfly Valves (3179 and 3223) spare units. GP-B Engineering Procedure P0761 Rev.- Ops Order No. W. W. Hansen Experimental Physics Laboratory STANFORD UNIVERSITY STANFORD, CALIFORNIA 94305-4085 Gravity Probe B Relativity Mission Vibration/leak Test 2.5 and 6 Vatterfly Valves (3179 and

More information

SB AXIAL FLOW VALVES

SB AXIAL FLOW VALVES SB9509.3 AXIAL FLOW VALVES The improved technology for pressure regulation The American Axial Flow Valve provides pressure and flow control in high capacity pipelines. It can be used for pressure regulation,

More information

INTERLOCKED METAL HOSE

INTERLOCKED METAL HOSE INTERLOCKED METAL HOSE HOSE FUNDAMENTALS Penflex interlocked metal hoses are made for a variety of specialized industrial applications and are available in a wide range of metals, styles and sizes. Interlocked

More information

PTF4 Pivotrol Pump (patented) version Dual Mechanism - Pressure Powered Pump

PTF4 Pivotrol Pump (patented) version Dual Mechanism - Pressure Powered Pump Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

ANDERSON GREENWOOD. Provides reliable overpressure protection in a cost effective package. Flow Control

ANDERSON GREENWOOD. Provides reliable overpressure protection in a cost effective package. Flow Control ANDERSON GREENWOOD Provides reliable overpressure protection in a cost effective package. Product Overview Anderson Greenwood s LCP Series pilot operated safety valve is designed to provide the reliable

More information

Type 1367 High-Pressure Instrument Supply System with Overpressure Protection

Type 1367 High-Pressure Instrument Supply System with Overpressure Protection Instruction Manual D100343X012 Type 1367 November 2017 Type 1367 High-Pressure Instrument Supply System with Overpressure Protection TYPE 252 FILTER 2ND-STAGE TYPE 67CF FILTER-STYLE REGULATOR INLET TYPE

More information

WHEATLEY WHEATLEY SERIES 500 SWING CHECK VALVE. Installation, Operation and Maintenance Manual

WHEATLEY WHEATLEY SERIES 500 SWING CHECK VALVE. Installation, Operation and Maintenance Manual WHEATLEY SERIES 500 SWING CHECK VALVE STANDARD INTEGRAL SEAT & OPTIONAL REMOVABLE SEAT 2" FP - 6" FP 150# - 1500# 8" FP - 12" FP 150# - 900# API 6D and B16.34 2" FP - 4" FP 5000# DRILLING PRODUCTION VALVE

More information

ARI-SAFE-SN ANSI Safety valve ANSI - safety valve Semi Nozzle (ANSI )

ARI-SAFE-SN ANSI Safety valve ANSI - safety valve Semi Nozzle (ANSI ) ARI-SAFE-SN ANSI Safety valve ANSI - safety valve Semi Nozzle (ANSI 150-300) ARI-SAFE-SN ANSI (Semi-Nozzle) ANSI-Safety Relief Valve Type-test approved acc. to ASME Code Section VIII-Division 1. UV-stamp

More information

CVI Valve Line. Exceeds the industry s highest standards for reliability and performance

CVI Valve Line. Exceeds the industry s highest standards for reliability and performance CVI Valve Line Exceeds the industry s highest standards for reliability and performance Available in the most standard models with the shortest lead times in the industry Exceptional quality every CVI

More information

FLAMMABLE GASES AND FLAMMABLE CRYOGENIC FLUIDS

FLAMMABLE GASES AND FLAMMABLE CRYOGENIC FLUIDS CHAPTER 35 FLAMMABLE GASES AND FLAMMABLE CRYOGENIC FLUIDS SECTION 3501 GENERAL 3501.1 Scope. The storage and use of flammable gases shall be in accordance with this chapter. Compressed gases shall also

More information

RELIEF VALVES. General Description

RELIEF VALVES. General Description RELIEF VALVES FOR CONDENSER SERVICE General Description Graham Viking Valves are produced in three basic designs: Horizontal, Vertical and Angle. The Horizontal and Angle valves are available with various

More information

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER RELIEF VALVE

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER RELIEF VALVE INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER RELIEF VALVE MODELS RV-1 RV-2 RV-2CP RV-3 DRAWING NUMBERS AD017A[ ] AD018A[ ] AD020A[ ] AD282BO MANUAL NUMBER IOM-033 REVISION Rev. E, 3/28/2016 TABLE

More information

v. Size shall be specified on drawings.

v. Size shall be specified on drawings. SPECIFICATION FOR VACUUM INSULATED PIPING Part 1 General 1. Submittals a. After award of contract and before executing any manufacturing, shop drawings and specifications shall be submitted to the customer

More information

Thanks for choosing EJAI SOLAR product

Thanks for choosing EJAI SOLAR product SPLIIT SOLAR WATER HEATER (( YYJ--S01 SERIIES )) IINSTALLATIION MANUAL www.ejaisolar.com ZHEJIANG EJAI SOLAR TECHNOLOGY CO.,LTD. 1 Thanks for choosing EJAI SOLAR product Content 1. Important Information....2

More information

Instruction Manual Pressure Relief Valve and Rupture Disc Chlorine or Sulfur Dioxide, Series 869

Instruction Manual Pressure Relief Valve and Rupture Disc Chlorine or Sulfur Dioxide, Series 869 Instruction Manual Pressure Relief Valve and Rupture Disc Chlorine or Sulfur Dioxide, Series 869-1 - 115.6020.15 These instructions describe the installation, operation and maintenance of the subject equipment.

More information

Dilution Refrigerator manual

Dilution Refrigerator manual Dilution Refrigerator manual Jaseung Ku November 24, 2011 Abstract This document provides a practical guide to dilution refrigerator operation and describes technical details about the hardware. It is

More information

HANDBOOK SAFETY DEVICES. Ed SAFETY DEVICES DS-ED 01/ ENG 1

HANDBOOK SAFETY DEVICES. Ed SAFETY DEVICES DS-ED 01/ ENG 1 HANDBOOK Ed. 2017 DS-ED 01/2017 - ENG 1 CHAPTER 9 BURSTING DISC DEVICES IN SERIES 3070 SCOPE Use: protection against possible overpressure of the apparatuses listed below, with regard to the operating

More information

Dean Pump Self-Priming Chemical Process Pumps

Dean Pump Self-Priming Chemical Process Pumps Bulletin C 1.2.34.7 Dean Pump Self-Priming Chemical Process Pumps php Series HEAD CAPACITY RANGE CHARTS php Self Primer - 2 Pole 3500 RPM 500 CAPACITY M 3 /HR 2900 RPM 50 HERTZ 25 50 75 125 150 400 TOTAL

More information

Halsey Taylor Owners Manual

Halsey Taylor Owners Manual Halsey Taylor Owners Manual Wall Mount Steel Refrigerated Fountains INSTALLER These series fountains are among the easiest to install Fountains on the market today. To assure you install these models easily

More information

HP/UHP Spring-Loaded Regulator

HP/UHP Spring-Loaded Regulator Description HP (High Purity) and UHP (Ultra High Purity) products are for service where the product must be kept free of contamination. The design is kept simple to minimise dead areas where contaminants

More information

Design of Pressure vessel for the Hydrocarbon release from the Vent Header Lines

Design of Pressure vessel for the Hydrocarbon release from the Vent Header Lines Design of Pressure vessel for the Hydrocarbon release from the Vent Header Lines Bhargav Mangesh Joshi 1 1Student, Department of mechanical engineering, Modern college of engineering, Pune-5 ---------------------------------------------------------------------***---------------------------------------------------------------------

More information

Type 299 Pressure Reducing Regulators

Type 299 Pressure Reducing Regulators Type 299 Pressure Reducing Regulators Fisher, Fisher-Rosemount, and Managing The Process Better are marks owned by Fisher Controls International, Inc. or Fisher-Rosemount Systems, Inc. All other marks

More information

Ball Float Steam Trap UNA 43 PN 16/CL 125/JIS 10K UNA 46 PN 40/CL 150/CL 300/JIS 10K/JIS 20K DN 80, 100, 150, 3", 4", 6"

Ball Float Steam Trap UNA 43 PN 16/CL 125/JIS 10K UNA 46 PN 40/CL 150/CL 300/JIS 10K/JIS 20K DN 80, 100, 150, 3, 4, 6 Data Sheet 819584-00 Issue Date: 01/17 Ball Float Steam Trap UNA 43 PN 16/C 125/JIS 10K UNA 46 PN 40/C 150/C 300/JIS 10K/JIS 20K DN 80, 100, 150, 3", 4", 6" UNA 43 hl, UNA 46 hl UNA 43 v, UNA 46 v with

More information

Chlorinator. MODEL C-731 (Floor Mounted)

Chlorinator. MODEL C-731 (Floor Mounted) Chlorinator MODEL C-731 (Floor Mounted) CHLOROTECH Model C-731 is the advance technology Chlorinator designed to feed chlorine gas at a controlled rate. The flow rate of gas is maintained by constant positive

More information

SABERINDO PACIF SABERINDO PACIFIC CIFIC SABERINDO PA. A Tyco International Company

SABERINDO PACIF SABERINDO PACIFIC CIFIC SABERINDO PA. A Tyco International Company CIF A Tyco International Company 1 Foam Concentrate CIF 3% AFFF -UL Listed -UL Canada Listed 6% AFFF 6 parts AFFF concentrate to 94 parts water -UL Listed- Foam Liquid -UL Canada Listed 3% FLUOROPROTEIN

More information

TOPIC: KNOWLEDGE: K1.01 [2.5/2.7] An atmospheric pressure of 15.0 psia is equivalent to... A psig. B psig. C psig.

TOPIC: KNOWLEDGE: K1.01 [2.5/2.7] An atmospheric pressure of 15.0 psia is equivalent to... A psig. B psig. C psig. P73 An atmospheric pressure of 15.0 psia is equivalent to... A. 30.0 psig. B. 29.4 psig. C. 14.7 psig. D. 0.0 psig. ANSWER: D. P273 A pressure gauge on a condenser reads 27.0 inches Hg vacuum. What is

More information

CASH VALVE TYPE KP BACK PRESSURE VALVES

CASH VALVE TYPE KP BACK PRESSURE VALVES A high capacity pilot operated back pressure valve that offers accurate control and dependable protection against overpressure conditions FEATURES Automatically maintains maximum pressure in a vessel or

More information

STANDARD FOR CONTROL VALVE SEAT LEAKAGE

STANDARD FOR CONTROL VALVE SEAT LEAKAGE 11-3 STANDARD FOR CONTROL VALVE SEAT LEAKAGE 1. PURPOSE 1.1 This standard establishes a series of seat leakage classes for control valves and defines the test procedures. 2. SCOPE & LIMITATIONS 2.1 Selection

More information

APPS-160 Gen 2 User Manual

APPS-160 Gen 2 User Manual APPS-160 Gen 2 User Manual Applicable Products: PN 11914406 - APPS-160 10 to 50 PSIG operating pressure PN 11918618 - APPS-160 40 to 85 PSIG operating pressure Rev 9/16/2004 Chart Ind. www-chart-ind.com

More information

MEGR-1627 Instruction Manual

MEGR-1627 Instruction Manual MEGR-1627 HIGH FLOW GAS REGULATOR Instruction Manual- Look Inside For: Description Installation Remote Vent Line Installations Startup and Adjustment Shutdown Maintenance Body Maintenance Procedures Diaphragm

More information

Relief Valves. Relief Valves. International, Inc. Company ACIRCOR. RS Differential NB 9.5mm. RVA In-line Differential NB 6 to 19mm

Relief Valves. Relief Valves. International, Inc. Company ACIRCOR. RS Differential NB 9.5mm. RVA In-line Differential NB 6 to 19mm s s RS Differential NB 9.5mm RVA In-line Differential NB 6 to 19mm RV Direct Acting NB up to 9mm LPR Low Pressure Differential NB 8mm We design, machine, build and test all our products on one site in

More information

WHEATLEY Series 500 Swing Check Valve

WHEATLEY Series 500 Swing Check Valve Document Number: TC003001-13 Revision: 02 WHEATLEY Series 500 Swing Check Valve Installation, Operation, and Maintenance Manual TABLE OF CONTENTS BILL OF MATERIALS...3 SCOPE...5 INSTALLATION AND OPERATION

More information

Preparation and Installation of the Sanitary BDI-FLX Sensor and Connection to the BDI-FLX Interface Cable

Preparation and Installation of the Sanitary BDI-FLX Sensor and Connection to the BDI-FLX Interface Cable GEP-6075 Rev. B 101574 Ref. I.D.: 16973 Preparation and Installation of the Sanitary BDI-FLX Sensor and Connection to the BDI-FLX Interface Cable WARNING USER SHOULD READ AND THOROUGHLY UNDERSTAND THESE

More information

BS Series Basket Strainer

BS Series Basket Strainer BS Series Basket Strainer Operating, Installation, & Maintenance Manual Corrosion Resistant Fluid and Air Handling Systems. Dated 04-26-12 PRESSURE DROP SIMTECH strainers are engineered to offer the lowest

More information

1301 Series High-Pressure Regulators

1301 Series High-Pressure Regulators Instruction Manual Form 1111 Types 1301F and 1301G March 2013 1301 Series High-Pressure Regulators! WARNING Failure to follow these instructions or to properly install and maintain this equipment could

More information

REFRIGERATION SYSTEM COMPONENTS

REFRIGERATION SYSTEM COMPONENTS REFRIGERATION SYSTEM COMPONENTS henrytech.com Conventional Oil Separators The function of an Oil Separator is to remove oil from the discharge gas and return it to the Compressor either directly or through

More information

MSC Guidelines for Refrigeration Machinery

MSC Guidelines for Refrigeration Machinery Procedure Number E1-32 Revision Date: 07/27/10 S. J. Kelly, CDR, Chief of Engineering Division References: a. 46 CFR Part 56.50-105 Low Temperature Piping b. 46 CFR Part 58.20 Refrigeration Machinery c.

More information

INSTALLATION, OPERATION AND MAINTENANCE MANUAL. Model Sanitary Vent SECTION I

INSTALLATION, OPERATION AND MAINTENANCE MANUAL. Model Sanitary Vent SECTION I INSTALLATION, OPERATION AND MAINTENANCE MANUAL Model 1100 Sanitary Vent IOM-1100 03-17 ISO Registered Company SECTION I I. DESCRIPTION AND SCOPE The Model 1100 is a stainless steel sanitary vent designed

More information

CP200 Series Commercial / Industrial Pressure- Loaded Pressure Reducing Regulator

CP200 Series Commercial / Industrial Pressure- Loaded Pressure Reducing Regulator CP200 Series Commercial / Industrial Pressure- Loaded Pressure Reducing Regulator May 2010 Figure 1. CP200 Series Pressure Loaded Regulator Features and Benefits Wide Range of NPT Body Sizes Easy to Install

More information

TITAN FLOW CONTROL, INC.

TITAN FLOW CONTROL, INC. PREFACE: This manual contains information concerning the installation, operation, and maintenance of Titan Flow Control (Titan FCI) Simplex Basket Strainers. To ensure efficient and safe operation of Titan

More information

North American Orifice Metering System

North American Orifice Metering System Combustion North American Orifice Metering System 8697 and M8697 Metering Orifices accurately measure gas flows to industrial burners. They are compact, inexpensive, and can be installed in individual

More information

PRESSURE TANKS HANDLING & INSTALLATION INSTRUCTIONS INSTALLATION MANUAL CONTROL VALVES

PRESSURE TANKS HANDLING & INSTALLATION INSTRUCTIONS INSTALLATION MANUAL CONTROL VALVES PRESSURE TANKS HANDLING & INSTALLATION INSTRUCTIONS CONTROL VALVES INSTALLATION MANUAL TABLE OF CONTENTS Receiving & Handling 3 Basic Handling Continued 4 Approved Lifting Methods 5 Installing Pressure

More information

POP Safety Valve. POP Safety Valve INTRODUCTION DEFINITIONS

POP Safety Valve. POP Safety Valve INTRODUCTION DEFINITIONS POP Safety Valve POP Safety Valve INTRODUCTION The effects of exceeding safe pressure levels in an unprotected pressure vessel or system, can have catastrophic effects on both plant and personnel. Safety

More information

GUIDELINES FOR CONDUCTING HYDROGENATION REACTIONS

GUIDELINES FOR CONDUCTING HYDROGENATION REACTIONS Page 1 of 5 GUIDELINES FOR CONDUCTING 1. Definition of Hydrogenation and Hydrogenolysis Reactions Hydrogenation reactions are synthetic transformations involving hydrogen, metallic catalysts (such as nickel,

More information