00 Experiment: Basic Lab Techniques, Compliance of GLP and Calibration of Glassware

Size: px
Start display at page:

Download "00 Experiment: Basic Lab Techniques, Compliance of GLP and Calibration of Glassware"

Transcription

1 00 Experiment: Basic Lab Techniques, Compliance of GLP and Calibration of Glassware OBJECTIVE: In this experiment you will learn the basic techniques when carrying out chemical analysis. You will learn how to use the analytical balance, calibrate Eppendorf pipettes, read volumetric glassware and calibration of glassware. Finally you will practice taking meticulous notes on your procedure and observation throughout this exercise. Equipment Chemicals Analytical Balance Burets (2) Thermometer KMnO 4 solid 100 ml Vol Flask 0-ml Beaker Stirring rod Deionized water 10-mL Vol pipet Slop bucket (400 ml beaker) 10-mL grad cylinder Aluminum slug 20 ml Vol Flask 12-mL Erlenmeyer flask (2) Pipet bulb pennies in container Rubber stopper or cork- 400-mL beaker SAFETY AND DISPOSAL INFORMATION Dispose of ALL solid permanganate, permanganate solutions, and washes containing permanganate into the proper, labeled Hazardous Waste Container in the hoods. If you are unsure about the location of the Haz-Waste container, ASK! Never pour any reagents or chemical down the sink. Please complete the prelab for the second day which is to generate the tables in your notebook. This lab starts on day2 of the semester!!! Those without a hard copy of this procedure and without a lab notebook will not be allowed to begin the calibration procedures. Please use care when using the analytical balance. Wipe all moisture left on balance. Before the end of the day, be sure the balance room is clean and all trash and waste have been disposed. Close the chamber window of your balance before excusing yourself from the balance room. It is everyone s responsibility to keep the balance room clean at all times. You may dispose of water down the drain. RECORDING DATA: Use only the lab notebook designated for this course otherwise you will lose 10 pts. Start on page 4 or in your lab notebook, saving the first few pages for table of content and miscellaneous information. If directed by your instructor, you will need to reproduce the data table in the next few pages in your lab notebook. Record all data in your lab notebook, and DO NOT use pieces of scrap paper while recording your work. If I observed you doing this, you will lose points in your technique grade. Record your procedure and observations in your notebook (see grading evaluation for this experiment). Remember for all experiments in this course, you absolutely need to use your Laboratory Notebook. Your instructor will confiscate pieces of scrap papers, on which you have written data or information, upon discovery. In other words, DO NOT EVER COME UP TO YOUR INSTRUCTOR WITHOUT YOUR LAB NOTEBOOK TO SHOW DATA OR TO ASK QUESTIONS, you will be marked down for not keeping with the protocol or for noncompliance of GOOD LAB PRACTICE. UNKNOWNS: The instructor will provide you the unknowns for this laboratory. If the instructor forgets, ask the instructor for the assigned unknown number. A numbered aluminum slug in a glass vial will be your designated unknown. You will weigh the aluminum slug to the precision of the scale. Upon completion of the procedure, place the slug back in the vial and return the unknown back to where you found it. If you have to repeat the weighing procedure, you will be issued a new unknown number to carry out your analysis. DISCUSSION: The purpose of this experiment is to introduce you to the tools and techniques necessary for success when carrying out chemical quantitative analysis. The techniques are considered one at a time, as though they were unit operations. You may well have performed each of these techniques in previous chemistry labs, or even in undergraduate research, and you may be absolutely certain you know how to perform these techniques well. This is immaterial, and you re probably wrong anyway. There s a wise, old adage: It isn t the things you don t know that get you into trouble. It s the things you know for certain that just aren t true. All volumetric ware should be painstakingly free of water breaks before being calibrated. Burets and pipets need not be dry; volumetric flasks should be thoroughly drained and dried at room temperature. The water used for calibration should be in thermal equilibrium with its surroundings. This condition is best established by drawing the water well in advance, noting its temperature at frequent intervals, and waiting until no further changes occur. It is very important that you never assume that your glassware is clean. Furthermore, do not ask another classmate or instructor if the glassware is clean, you are responsible for your own work not your classmate or instructor. The Analytical Chemistry laboratory requires a substantially higher level of precision, accuracy, laboratory technique, and cleanliness than any other laboratory you have taken. You have to be both meticulous and patient in this course. If you are careless in your work, analytical chemistry is not for you. Drop this course now. Much as a golfer studies, practices, and improves individual discrete skills of the game (the grip, the stance, the swing, driving, putting, etc.) and puts these all together when playing a round of golf, the chemist must study, practice, and improve individual laboratory techniques such as pipetting, weighing, transferring solids and solutions, and reading a buret to do a complete analysis properly. Do not be lazy and cut corners. This course is to help you hone your skills when working in a laboratory so take advantage of the experience. The whole point of this experiment is to learn proper technique for individual skills first, before attempting additional labs. If you can t read a buret properly or pipet accurately or reproduce the technique reliably, it is foolish to attempt a complete volumetric analysis. Therefore, if any parts of this experiment need to be redone to satisfy the various tolerance levels, redo them as soon as possible, and 1

2 document the new data set in your lab notebook. If you do not meet tolerance limits after two or three tries, you are obviously doing something wrong. Ask for assistance from your instructor. GRADING OF EXPERIMENT #1 This experiment is graded differently from the other labs. Each part in the procedure must be passed within the acceptable tolerance. Each part is independent of the other. Once one part (parts A, B, C, D and E) is successfully completed, points will be earned for successful completion. An additional 1 pts will depend on your record keeping techniques and how well you compile your results. To ensure that these important skills have been mastered in a timely fashion, this experiment MUST be successfully completed and turned in by deadline as outline in the lab schedule. If not, zero points (0 pts) will be awarded. There is no partial credit on the procedural part of the experiment. You will earn pts or 0pts for each technique. After completion & turning in the write-up for the lab, additional points will be added to the overall score depending on unknown scores & the write-up. PART A: USE OF THE ANALYTICAL BALANCE TO CALIBRATE EPPENDOEF PIPPETTES ( + -pts Unknown Aluminum Slug) Read section 2.6 of the Harris Text (8 th edition) Automatic adjustable micron pipettes have become an indispensable tool in today's biochemistry laboratory. They are highly advantageous due to their accuracy, ease of use, and wide range of volume deliveries available. You will be using the Eppendorf line of pipettes in this lab. The identification numbers found on the side, as well as the color on the top button, give the pipette size. The pipettes provided allow for delivery of microliters in the following volume ranges: Micro Pipette VWR Fingerpipette II Volume Range ul ul Each micro pipette is to be used with a specific disposable tip provided in the plastic racks. These pipettes must never be used without a tip! The small clear tips are used with the Eppendorf VWR, , and the large blue tips with the Eppendorf Tips may be used more than once when delivering the same solution, but always replace the tip when changing solutions, when using sterile solutions, or if it becomes dirty, contaminated, or if liquid droplets seem to be retained along the pipette walls. Tips are not stable for chloroform or concentrated nitric or sulfuric acid. In most cases tips are best used for aqueous solutions. Calibrating pipettes frequently is necessary to identify pipettes that are not delivering accurately. Before calibrating the pipettes, practice using the pipettes and get a feel of the button. The following is a specific sequence of steps that are followed each time a transfer is desired. This is the forward mode. 1. Set appropriate volume on appropriate model. 2. Carefully attach appropriate tip to model. Do not press down on tip too hard, but do insure that tip is firmly attached. 3. Press the large button until the first stop. 4. Place the tip in the solution to be transferred.. Slowly and smoothly release the large button. 6. Inspect solution in tip to confirm that no air bubbles are present. 7. Place tip gently against the side of destination container. 8. Push large button to first stop. 9. Push large button to second stop. 10. If necessary, dispose of tip by pushing smaller button on the back of pipette grip. These pipettes are very fragile and expensive. You are the primary users of these fine instruments and therefore, it is your responsibility to maintain the pipettes in fine working condition. You will be held responsible for any damage to your pipettes due to neglect. In addition to the guidelines already provided, the pipettes should never lay in a horizontal position with a full tip. If you draw too much liquid then the pipettes become flooded in the inside with the liquid. Make sure you use the correct tips to prevent this. Calibration is carried out at ambient temperature. In addition, obtain an unknown number from your instructor for an aluminum slug. Do not use the same unknown as a classmate otherwise you will split the points. Write your unknown number and the mass data in an organize table in your lab. You will be given a pipette and also be assigned a balance, be sure to use this same balance for the duration of the course. Write in your notebook the ID of the balance you are assigned. It is up to you to keep your balance clean at all times. If your balance has been un-kept, you will be penalized in your lab technique score. It is also important to write notes to yourself on the proper operation of the scale. Write these notes in your lab notebook All adjustable pipettes should have their calibration checked periodically. The easiest way to accomplish this task is to pipette an indicated volume of a solution of known density, weigh the amount transferred, and determine if the measured volume corresponds to the indicated volume. The density of distilled water at 2 C is g/ml; an Eppendorf 100 pipette set to 0 should deliver µl, which will weigh g based on the formula: Weight = Density / volume. In order to establish the accuracy of your pipettes and to test the reproducibility of your pipetting technique, you will pipette ten aliquots of distilled water from one of your pipettes, carefully recording the cumulative weight after each addition. You will calibrate each pipette using 2 trials at 1 settings (80%). So, if you are calibrating a uL pipette, set the volume to 800uL (.8 ml). If you have time, also do the same procedure at the 20% volume setting. You will be ed the calibration technique and the proper technique or you can download it from the website. 2

3 Procedure, PART A After your instructor has instructed you on the proper use of the electronic balance and you have become familiar with its use, decide which pipette to calibrate. Since there is no time to calibrate all your pipette, it is recommended that you calibrate the pipette that is used most often, the uL pipette (at 80% capacity). For this part choose an aluminum slug unknown that is the same as your Eppendorf / Buret number. That is if you have Eppendorf/Buret #4, your unknown number in the course will also be #4. 1. Go to the analytical balance that has been assigned to you. 3 Make sure the balance is level and had been warmed up for at least 30 min. Place a weighing boat on the analytical balance and accurately weigh the empty boat to the full resolution of the balance (0.1mg). This first procedure will be for setting of 80% volume of your pipette. Now, carefully pipette an aliquot of distilled water into the boat and record the weight. Repeat this process recording the cumulative weights of ten aliquots. Remove and dry the weighing boat with a Kim-wipe and repeat the process for the second trial using the same pipette at 80% volume. At the end of the experiment you should have two sets of ten weights for the pipettes you have selected to calibrate. Be sure that you have recorded your data in your notebook. Use your thermometer to measure the temperature of the distilled water and use the table of values below to find the density. If you have time repeat this procedure at 20% volume. You can repeat this for your other pipettes to determine their accuracy. This is not required. Temperature density Temperature density Temperature density ( C) (g ml -1 ) ( C) (g ml -1 ) ( C) (g ml -1 ) Take the vial assigned to you containing the aluminum slug. Be sure that you have a unique unknown number from your classmate. Also remember that if you do not record your unknown number in your notebook, you will not receive any credit. Record condition of the unknown, weigh the unknown aluminum slug and record its mass. Return the Al slug to their appropriate vial as soon as you have successfully completed the procedure and return the vial to your instructor. 3. Using Excel, type in each of the datasets as (cumulative weight - weight of empty boat) versus (total volume added). Plot each dataset (linear option) and fit each plot with a linear regression. Record the slope of the plot, the correlation coefficient and obtain an error estimate for each dataset. Printouts of these plots should be included in your lab notebook. Share this information with your lab partner 4. For all two datasets, convert the cumulative weights into a table of weights per aliquot. Enter these data into the spreadsheet and obtain appropriate statistics for each set. Divide the mean weights by the density (corrected for temperature) to obtain the mean volumes delivered. Calculate the percent error for each of the two volume pipettes. Share this data with your lab partner. In your laboratory notebook you should include the plots prepared above and a table reporting slopes, and the mean, median and standard deviation for each dataset, as determined from your analysis. A second section of the table should report these same data as obtained by your lab partner. You should also comment on the accuracy and the reproducibility of your pipetting, a comparison of your error and your partner's and the correlation between the volumes indicated on the pipettes and the actual volumes delivered. Please note that your notebook will be scrutinized by your instructor and you should utilize this opportunity to practice writing for future and more involved laboratory reports. NOTE: NEVER transfer chemicals inside an analytical balance. In this experiment, however, it is okay to pipette water to a weighing boat. If you spill any liquid on the balance, soak up the residual liquid immediately with Kim-wipes and contact your instructor. PART B: QUANTITATIVE TRANSFERS (-pts) This procedure is designed to provide experience for the correct use of the volumetric flask. Record your observations in your lab notebook. 1. Tap a very small amount of potassium permanganate, KMnO 4, from the stock bottle onto a piece of folded glassine paper or into a small clean beaker or a plastic weighing boat. (Note: Returning chemicals back into stock bottles should never occur as this may contaminate the entire bottle. Avoid putting a spatula into a stock bottle. Tap out a small amount if at all possible.) 3

4 2. Tare a clean, dry 0-mL beaker on an electric top-loading balance that is found at the front of each lab counter. Use this scale and not the analytical balance for this procedure. (Note, for weighing that do not require precision to the tenth of milligram, use this top-loading balance.) Add about ~0.2 g of KMnO 4 to the beaker, this will be used to prepare a 100-mL stock solution. 3. Dissolve the potassium permanganate in about 20 ml of distilled water, stirring gently to avoid loss. This is nearly a saturated solution, and some care is required to dissolve the crystals completely. 4. Quantitatively transfer the solution into a 100-mL volumetric flask using a small funnel. To prevent the solution from running down the outside of the beaker, pour the solution down the stirring rod, and then touch the rod to the spout of the beaker to remove the last drop. If needed, ask your instructor to show you how to do this. Add more water to the beaker, stir, and repeat the procedure. Record the amount of washing and the number of times required to quantitatively transfer the permanganate from the beaker to the flask. Finally, rinse the last portions of solution from the stirring rod into the volumetric flask with a stream of water from the wash bottle. Rinse the funnel and remove it. Carefully dilute the solution in the flask until the bottom of the meniscus is even with the graduation mark.. Stopper, invert, and shake the flask. Return it to the upright position, and allow the air bubble to return all the way to the top of the neck. Repeat until the solution is completely homogeneous; a minimum of 10 inversions and shakings will be required. Save this solution for Part C. PART C: TAKING AN ALIQUOT (-pts) Whenever a buret or pipet is used to deliver a measured volume of solution, the liquid it contains before a measurement must have the same composition as the solution to be dispensed. The procedure referred to in this section is called conditioning your glassware. The following operations are designed to illustrate the minimum effort needed to ensure this. NOTE: During this part, collect all the permanganate solutions and rinse waste in a large beaker ( slop bucket ). At the end, all the permanganate is to be disposed of in the proper, labeled waste container. No permanganate should go down the drains. 1. Before beginning this section, make sure you know how to use the Brinkman pipet bulb mechanism in your lab drawer. Your instructor will illustrate how to use this or show you a video on the proper use. [Never draw so much solution that it fills the suction mechanism. If you do this you will ruin the suction mechanism and this will reflect in your lab technique score.] Fill a pipet with the solution of potassium permanganate and let it drain completely into a waste beaker. Wait seconds, then touch the tip of the pipet to the side of the beaker. Draw a small amount of distilled water from a 0-mL beaker into the pipet, rinse, and discard the rinse solution. Do not fill the pipet completely; this is wasteful, timeconsuming, and inefficient. Just draw in a small amount, tilt the pipet horizontally, and turn it to rinse the sides. Determine the minimum number of such rinsing required to completely remove the permanganate color from the pipet. [Hint: Look at the liquid that collects in the tip of the pipet against a white background to see if there is any coloration.] If your technique is efficient, three rinsing should suffice. (Note, if you are not comfortable with the Brinkman pipet bulb, ask for an alternate.) 2. Fill the pipet again with permanganate and proceed as before. This time determine the minimum volume of rinse water required to remove the color by collecting the rinsing in a small graduated cylinder (less than ml of rinse water is enough with efficient technique). Again, check the pipet tip as before for any coloration. **3. Upon the discretion from your instructor, you may be asked to show off the following aliquot technique. Condition a 10-mL pipet three times with the solution of potassium permanganate you prepared (above). Pipet 10 ml of the permanganate solution (see section B, step 2) into a 20-mL volumetric flask. Carefully dilute the solution to volume, try to minimize the mixing of the 10-mL KMnO 4 solution with water in the dilution process. Now, mix the solution by repeatedly inverting and shaking the flask. (Note the effort required to disperse the permanganate color uniformly through the solution.) Rinse the pipet with the solution in the volumetric flask. Pipet a 10-mL aliquot of the solution into a 12mL Erlenmeyer flask. Remember to condition the pipet before drawing the 10-mL aliquot. ** You may be picked at random to demonstrate your technique. 4. If the laboratory instructor considers your technique satisfactory, ask him/her to initial your report to indicate passing this part of the lab. To use the Brinkman Pipet Bulb. 1. Squeeze air out of bulb to create a partial vacuum. 2. Insert a pipet into the pipet receptacle. 3. Place tip of pipet well into the liquid. 4. Push lever up to draw fluid above desired calibration line. DO NOT DRAW FLUID INTO BULB!.. Press level down to deliver fluid to new container. 6. Press bulb to blow out last of the liquid from the pipet. For more details go to: pipet.html 4

5 PART D: CALIBRATION OF A GRADUATED PIPET (-pts) Read section 2.6 of the Harris Text (8 th edition) The calibration of an analytical transfer pipet is a relatively straightforward procedure. The proper technique is readily learned with practice, care, and attention to detail. Note that this is a manual technique. It must be learned; it does not magically appear on the first try, not unlike learning to hit a golf ball. With some practice, however, you ought to be able to handle a pipet about as well as who routinely works in an analytical lab. With the exception of a simple weighing, this experiment is capable of being the most accurate and precise set of measurements you re likely to ever perform in a lab course. 1. Obtain the following equipment: Pipet bulb (Brinkman pipet bulb); 12-mL Erlenmeyer flask with a dry cork or rubber stopper; 400-mL beaker of distilled water equilibrated to room temperature; and a thermometer. 2. Clean a 10-mL pipet, and be sure that your pipet is ultra clean. Cleaning is usually accomplished by drawing some warm soapy water into the pipet bulb, wetting the sides, and shaking the soap inside the pipet. If that doesn t work, soak the entire pipet in soapy water overnight or longer. You must clean pipets, burets, and other pieces of volumetric glassware, so that no droplets of reagent remain on the internal surfaces when they are drained; there should be no water break. This is very important for accurate and reproducible results. If reagent gets hung up inside a pipet, you obviously cannot deliver the nominally stated volume. You should have already cleaned your pipet properly during the check-in period. 3. Using the analytical balance, weigh the flask and stopper and record the mass to the nearest 0.1 mg. Do not touch the flask with your fingers after this weighing. Use tongs or wear gloves. 4. Read and record the temperature of the water.. Pipet ml of the distilled water into the flask using the technique described above. Re-stopper the flask, weigh it, and record the mass of the stoppered flask plus the water. 6. Add a second pipet of water to the flask, without pouring out the 1st aliquot, removing the stopper just before the addition. Re-stopper, weigh, and record the weight. Repeat the entire procedure for a minimum of four readings that agree to within a total range of less than about 0.02 g for all the readings. [If you have what you consider 3 good replicates and one that seems bad, try the Q-test to see if the outlying value can be rejected.] If your values seem very non-reproducible, throw out all your data and do another full set of 4 minimum, paying closer attention to what you re doing. If these still do not reproduce well, there is something clearly wrong with your technique. Seek assistance from your instructor. Have your instructor look over your measurements in the data sheet and initial it upon satisfactory completion of this section. 7. Correct the apparent masses of the aliquots for the buoyancy effect of atmospheric air to get the true masses as described below. Then calculate the true volume of the pipet using the density of water at the temperature(s) of each aliquot. 8. Report the average true volume of your pipet and the associated standard deviation of your values. Correction for Buoyancy 3 A buoyancy error will affect data if the density of the object being weighed differs significantly from that of the standard weights (inside the balance for an electric balance). This error is due to the difference in the buoyant force exerted by the medium (air) on the object weighed and on the weights themselves. The correction is made using: m corrected = m observed + m observed [(d air /d object ) (d air /d weights )] where m is the mass in grams of the corrected and initially observed values of the object weighed (in this case, distilled water, see table below), and d is the density in g/cm 3 of air, the object, and the weights. For all but the most exacting work, this correction is negligible for solids and liquids having a density of 2 g/ cm 3 or greater. Correction for buoyancy is required only for measurements that require the highest accuracy, for gases, or for low-density solids and liquids. The density of the weights used in electronic single-pan balances ranges from 7.8 to 8.4 g/cm 3, depending on the composition of the weights. Using d weights = 8 g/cm 3 is adequate for most purposes. The d air = g/ cm 3 at room temperature and pressure.

6 PART E: BURET ASSIGNMENT: READING OF BURET (-pts) Read section 2.4 of the Harris Text (8 th edition) 1. You will be issue 2 burets for this course. Be sure to label your burets because these will be stored under hood #1 since burets cannot fit in your drawer. You can use a wax pencil or a label tapes to do this. Burets are normally stored upside down so that the inside surface of the part of the section where you will take your reading will remain wetted and drain well. It is also recommended that upon storing the buret, you place parafilm on the tips of the buret so that you minimize contamination to the interior of the buret. Use the buret stand to keep the buret vertical. Puncture a pin size hole at the ends so as to have any residual water drain out of the buret. 2. Invert the buret and tap the section lightly to remove any solvent that might remain in the sealed tip and let it drain for at least sec. Use a buret reading card to estimate the readings to the nearest 0.01 ml. A buret card is easily made by making a very heavy, black horizontal rectangle in the center of a 3 x file card. 3. Over-fill the buret with distilled water. You can over-fill the buret by adding distilled water past the 0.0-mL mark. Make sure that there are no air bubbles trapped in the tip. If so, rapidly open valve, full throttle until the bubbles are flushed out. If this does not work, sometimes a quick vertical jerk will loosen any residue lodged at the tip of the buret. Refill the buret if the water level falls below the 0.0-mL mark. 4. Drain the buret down to someplace between 0 and 1 ml. Do not try to bring the buret to exactly 0.00 ml, as this is a waste of time. The zero reading on all but an automatic buret is always some finite non-zero reading.. Wait at least seconds before taking the initial or zero reading. Why? Take the initial or zero reading and the other buret reading using a buret reading card. 6. Now let about ml run into a 12-mL Erlenmeyer flask. Wait at least 30 seconds and take the final reading. (The amount of solution in the Erlenmeyer flask is equal to the final reading minus the zero reading.) Write down the final reading on the data sheet provided, the time you waited before reading the buret, and then ask your instructor to take the final reading. Compare the two readings. They should agree within 0.01 ml. Do they? Notice that the final digit in the buret reading is the estimation of the distance between two marks on the buret. The instructor will initial your datasheet upon satisfactory completion of this part. 7. Refill the buret, and take a new zero reading. Now add 30 drops to the Erlenmeyer flask, and take the final reading. Calculate the average volume of one drop, then repeat this except with 40 drops and calculate the average volume of a drop. Record these results and compare them. Now, practice adding half-drops to the flask. Calculate the average volume of your half-drops. In several titration experiments, you will want to try to get half-drop end points for good precision. PART F: CALIBRATION OF BURET (10-pts) (Taken from C. Harrison, SDSU) You may calibrate just one or both of your buret. If you decide to do only one, then remember that when doing your titrations, you want to use the calibrated buret for precise measurements. There are inherent errors in the volumes indicated in the barrel of a buret, which will cause your results to deviate. For this reason you will need to calibrate your burets. Because the burets do not drain in its entirety during a single titration, calibration must be done in 10 ML increments. 1. For this calibration you will need a stopper flask of 0 ml or greater (but not to exceed the balance weight limits), DI water, a thermometer and your burets. Before you begin, be sure your burets are clean and the stopcocks are functioning properly. 2. Fill a clean, large (~400 ml), beaker with DI water, insert a thermometer and give the water time to come to equilibrium with the room temperature. 3. Prepare a table in your lab notebook, similar to the ones on the following page. You will need to perform the calibration process at least twice to obtain matched, replicate data for the calibration. 4. Record the temperature of the DI water. Record the mass of the flask and stopper.. Fill the buret with enough of the DI water so that the meniscus is between the 0.01 and 0.30 ml lines; ensure that there are no air bubbles in the tip of the buret. Do not attempt to fill the buret to 0.00 ml, this is pointless, time consuming and does not provide any benefit to an analysis. 6. Record the initial volume of the buret. Next titrate water into the flask until approximately 10 ml have been delivered. 7. Stopper the flask as soon as you are done delivering the water. Record the new volume on the buret and the new mass for the stoppered flask. 8. Repeat the process for each 10 ml increment of the buret - do not bring the level of the water below the 0.00 ml line as you cannot measure the volume beyond that point. The whole process will need to be repeated a second time in order to confirm the results of the first calibration. In some cases, multiple calibration attempts will be needed to ensure that the calibration is accurate. 6

7 Calculations: The calculations of true weight and true volume are obtained using the buoyancy correction and density calculation as performed for the pipette calibration (page 16). All other calculations are direct subtraction or additions. The cumulative correction is the sum of the correction values of each or the preceding intervals Error Check To check for any arithmetical errors in the table a simple equation can be used. The letters in the equation below are to be replaced with the values in the table cells with the corresponding letter (e.g. C = -0.01) A - B + C = D - E + (G-F) The difference in value on both sides of the above equation should be within 0.02 of each other. If the difference is greater than 0.02 there has been a calculation error in the table and it must be corrected. 7

8 Calibration Check In order for a calibration to be accurate it must be replicable. Therefore you will do two (or more) calibration tables for your buret. Once the calculations for the table are complete and each table has passed the error check (above) the data can be compared to see if the calibration was reproducible. The tables on the previous page each had a set of cells that were shaded in light grey, the values in these cells (copied below) need to be compared between tables. To compare the values, subtract the value segment correction of trial 2 from that of trial 1. The errors in the individual segment corrections must be less than or equal to 0.02 ml. For the total cumulative correction, the error can be no greater than 0.04 ml. In the example below, the calibration failed because the error in the corrections for the ml segments differed by more than 0.02 ml. Thus, a third calibration must be done. Calibrated Volume Once you have completed the calibration of the buret you will need to generate a calibration graph so that you can make use of the information that you have collected. Use the grids in your lab manual in order to has been included at the front of this lab manual for you to use in making your calibration graph. The graph will be a simple tool that you can use to correct for errors in the measured versus actual delivered volume from your buret. To construct the graph, determine the average correct for each 10 ml segment of your buret, based on the two replicate calibrations. Once you know the average correction volume, plot this value against the nominal volume at the end of each segment (e.g. 10, 20, 30 ml). The graph below is a calibration graph based on the data above (presume that the correction for ml in trial 2 had an error of 0.00 ml). You will use the graph to determine the proper volumes delivered from your buret. Simply record the value read from your buret, then apply the appropriate correction to your titration calculation 8

9 Example: Calculations and Post-Lab Write-up (10 pts) An excel spreadsheet may be available to you so that you can take the measurements from this lab and automatically perform needed calculations. If one is available, use excel to perform all pertinent calculations. If an excel template is not available, you should generate one. You can use the structure of the datasheet here to give you a sense of how to organize your data in the excel spreadsheet. You will be asked to generate spreadsheets through out this course so you will develop skills on producing data sheet that can be easily analyzed. While using excel to present your data and to perform repetitive calculations is convenient, you must however show a sample manually calculation in your lab notebook and especially when the procedure instructs you to do so. You need not worry about a sample calculations for some statistical calculations however like the standard deviation, simply state that the results was determined by an excel function. If your class is using a virtual cloud drive to store data, i.e., Google Drive or DropBox, you should store the result in this experiment in the appropriate folder in the virtual drive. If you don t know how to do this, ask your instructor for help. Summarize each of the part of this experiment and discussed how each of these parts are important in Analytical Chemistry and what you learned in the procedural process. Keep your total summary to one type written page. REFERENCE 1. D. A. Skoog, D. M. West, F. J. Holler, and S. R. Crouch, Analytical Chemistry: An Introduction, 7th ed. Chapter 2, pp Mark J. Rudin, William H. Hohnson, UNLV, Dept of Health and Physics 3. Topic on Analytical Balance and Buoyancy correction, Section 2.3 of the Harris Text (8 th edition) 4. Topic on Burets, Section 2.4 of the Harris Text (8 th edition). Topic on Pipets an Syringe, Section 2.6 of the Harris Text (8 th edition) 9

10 00 Basic Lab Techniques in Analytical Chemistry; Calibration of Glassware Reproduce this table in your lab notebook / Score Last Name First Date Datasheet. Part A(i) Use of Analytical Balance and Pipette Calibration Part A (i) Adding water from pipette in Analytical Balance Trial 1 Trial 2 Trial 1 Trial 2 Pipette ID -Total Running Mass -Total Running Mass Pipette ID -Total Running Mass -Total Running Mass Mass of each drop Mass of each drop Mass of each drop Mass of each drop Readings of Balance after tare Reading of Balance after tare # 1 # 1 # 2 # 2 #3 #3 #4 #4 # # #6 # 6 #7 #7 #8 #8 #9 #9 #10 #10 Total mass for drops 1-10 Total mass for drops 1-10 Statistical Analysis: Pipette #1 Pipette #2 Average Mass of drops (g) Standard deviation (s) Relative standard deviation or coefficient of variation (CV). A(iii): Weighing unknown mass of Aluminum Al Slug Unknown # Condition Mass (g). Instructor's initial: Initials 10

11 Part B Qualitative Transfer Part B (i) Preparing 100-mL KMnO 4 solution Observation Data Step 2 Mass KMnO4 Step 4 Amount of washing to transfer KMnO4 from beaker to flask (ml) Part C Taking an Aliquot Part C (i) Using a pipet and suction mechanism to prepare a solution. Observations Data Step 1 Minimum number of rinse to completely remove KMnO 4 color from pipet Step 2 Minimum volume of rinse water required to remove KMnO 4 color from pipet Step 3a: Preparing 20 ml stock solution, Step 3b: Aliquot transfer of 10-mL pipet to 12mL Erlenmeyer flask, Instructor's initial Initials Part D Calibration of a Pipet Part D Weighing volumes of water Data Step 2, clean pipet Step 3: Mass of 12mL Erlenmeyer flask and stopper Step 4: Temperature of water Step : Mass of flask after transfer 10mL DI water (g) Step 6a: Mass of flask after 2nd transfer 10mL DI water (g) Mass (g) Apparent Mass Corrected Mass Step 6b: Mass of flask after 3rd transfer 10mL DI water (g) Step 6c: Mass of flask after 4th transfer 10mL DI water (g) Average True Volume and standard deviation Instructor's initial Initials 11

12 Part E Use of Buret Part E (vii) Reading a buret -ml aliquot reading V i Time V f V Total Observations: Instructor s reading Initial Part E (viii) Counting Drops Avg Vol * Determining volume in a drop and half-a-drop V i drops V f V Total per drop Observations (1 drop procedure, 30 total drops): * Show calculations here Observations (1 drop procedure, 40 total drops): * Show calculations here Observations (1/2 drop procedure, 30 total half-drops): * Show calculations here Observations (1/2 drop procedure, 40 total half-drops): * Show calculations here Observations (mulligan): * Show calculations here 12

13 13

14 00 Experiment: Basic Lab Techniques and Compliance of GLP Analytical Chemistry 21 # CRITERIA (Tentative point distribution) pts A Use of the Analytical Balance ( + ) i. Record Keeping of Pipet Calibrations: Notes on using a balance. Record keeping for pipet calibration. Observation in complete sentences Precision in measuring mass ii. Mass of Unknown, Aluminum Slug Unknown number data Unknown mass (True) / (Recorded) Notebook initial by instructor. B Quantitative Transfer () i. Recording data and technique in quantitative transfer Notes on preparing KMnO 4 solution. Notes on number of washing to quantitatively transfer from beaker to flask C Taking an Aliquot ( + ) i. Using the Brinkman pipet Notes on using the Brinkman pipet and making the transfer Technique on using the Brinkman pipet (instructor's notes) Notes on number of rinse required to remove permanganate purple color ii. Demonstration to instructor Grade on technique for conditioning and preparing KMnO4 solution demo to instructor. Notebook initial by instructor. D Calibration of Pipet ( + ) i. Preparing pipet Notes preparing pipet Mass of flask, stopper and water. Precision and accuracy ii. Buoyancy correction procedure and calculations Analysis of 3 good weighing. Buoyancy correction calculation. Average "True volume" of pipet. E Buret Assignment and Proper Reading of your Buret ( + ) i. Caring and labeling buret Notes on caring and storing buret ii. Conditioning and preparing buret Notes on preparing and conditioning buret Notes on using the buret card to read meniscus of buret. iii Reading buret to correct precision Instructor reading confirmation. Reading should be with in +/ ml and correct precision iv. Practice half drop technique Notes on technique of half-drop techniques. Lab Techniques / Record keeping / Excel Workup () Following directions of lab and course. Precision of work, sound statistical analysis, conclusion of results Upkeep of notebook, notebook preparation and using proper notebook as instructed by syllabus Working diligently and independently without excessive guidance by others. 0 pts Instructor's Comment 14

VOLUMETRIC TECHNIQUES

VOLUMETRIC TECHNIQUES REVISED 10/14 CHEMISTRY 1101L VOLUMETRIC TECHNIQUES Volume measurements are important in many experimental procedures. Sometimes volume measurements must be exact; other times they can be approximate.

More information

CHEM 321 Experiment 1

CHEM 321 Experiment 1 CHEM 321 Experiment 1 Basics Review and Calibration of Volumetric Glassware There are three types of containers used in lab to contain or deliver liquids: volumetric, ordinary and disposable glassware.

More information

CHM250 Calibration and Measurement Lab. Balance Calibration

CHM250 Calibration and Measurement Lab. Balance Calibration CHM250 Calibration and Measurement Lab Green Profile Balance Calibration Introduction: Balances that are properly operated, calibrated and maintained are crucial for laboratory operations. The accuracy

More information

Measuring Mass and Volume

Measuring Mass and Volume Measuring Mass and Volume Experiment 2 Expt 2 Measurement.wpd INTENT The purpose of this experiment is to introduce some fundamental aspects of the measurement making process as well as to introduce some

More information

CH2250: Techniques in Laboratory Chemistry. Outline Measuring Mass Measuring Volume Significant figures. Mass Measurement

CH2250: Techniques in Laboratory Chemistry. Outline Measuring Mass Measuring Volume Significant figures. Mass Measurement CH2250: Techniques in Laboratory Chemistry Outline Measuring Mass Measuring Volume Significant figures Mass Measurement Mass Measurement Measure mass not weight Mass is measured with a balance (a scale

More information

The use of the analytical balance, and the buret.

The use of the analytical balance, and the buret. 1211L Experiment 1. Density 2015 by H. Patterson Instructor Notes: Students make measurements individually then share data to make the graph. There are four volumetric measurements to be studied; 3.00

More information

Calibration of Volumetric Glassware

Calibration of Volumetric Glassware Calibration of Volumetric Glassware Introduction This set of laboratory experiments is designed to introduce you to some of the apparatus and operations you will be using during the remainder of this course,

More information

BASIC LABORATORY TECHNIQUES (Revised )

BASIC LABORATORY TECHNIQUES (Revised ) BASIC LABORATORY TECHNIQUES (Revised 1-6-13) A. WEIGHING The determination of the quantity of matter in a sample is most directly determined by measuring its mass. The process by which we determine the

More information

Hands-On Experiment Density and Measurement

Hands-On Experiment Density and Measurement Hands-On Experiment Density and Measurement GOALS: 1. To measure liquid volume as accurately as possible with graduated cylinders. 2. To measure the volume of irregular shaped solid objects by liquid volume

More information

1. Determining Solution Concentration

1. Determining Solution Concentration In this exercise you will determine the concentration of salt solutions by measuring samples with known concentration and making a calibration curve. You will review units of concentration, and how to

More information

CHM Introductory Laboratory Experiment (r17sd) 1/13

CHM Introductory Laboratory Experiment (r17sd) 1/13 CHM 110 - Introductory Laboratory Experiment (r17sd) 1/13 Purpose This introductory exercise will familiarize you with a few of the measurements we make in the chemistry laboratory and the level of uncertainty

More information

CHM 100 / Introductory Laboratory Experiment (r10) 1/11

CHM 100 / Introductory Laboratory Experiment (r10) 1/11 CHM 100 / 110 - Introductory Laboratory Experiment (r10) 1/11 Purpose This introductory exercise will familiarize you with a few of the measurements we make in the chemistry laboratory and the level of

More information

BASIC LABORATORY TECHNIQUES (Revised )

BASIC LABORATORY TECHNIQUES (Revised ) BASIC LABORATORY TECHNIQUES (Revised 1-2-16) (See Appendix II: Summary for making Spreadsheets and Graphs with Excel and Appendix III parts C, C1 and C2: Significant figures, scientific notation and rounding)

More information

Lab Equipment ANALYTICAL BALANCE

Lab Equipment ANALYTICAL BALANCE Lab Equipment ANALYTICAL BALANCE Analytical balances are used for very accurate, quantitative measurements of mass to the nearest 0.001 g. (Some read to 0.0001 g.) These are delicate instruments, subject

More information

Experiment #2. Density and Measurements

Experiment #2. Density and Measurements Experiment #2. Density and Measurements Goals 1. To measure and record length, volume and mass accurately with the correct number of significant figures 2. To use significant figures correctly in calculations.

More information

CHM 317H1S Winter Section P Procedures and Tables

CHM 317H1S Winter Section P Procedures and Tables CHM 317H1S Winter 2018 Section P Procedures and Tables Procedures Page 1 Standard Operating Procedures Throughout the laboratory portion of this course, you will be required to perform a number of operations

More information

Lab 1. Instrumentation Familiarity: Using Micropipetters and Serological Pipettes

Lab 1. Instrumentation Familiarity: Using Micropipetters and Serological Pipettes Instrumentation Familiarity: Using Micropipetters and Serological Pipettes Introduction: In molecular biology we sometimes need to measure volumes as small as one millionth of a liter (a liter is about

More information

Laboratory #2 Pipetting Technique and Micropipette Calibration Skills=40 pts

Laboratory #2 Pipetting Technique and Micropipette Calibration Skills=40 pts Laboratory #2 Pipetting Technique and Micropipette Calibration Skills=40 pts Objectives: Upon completion of this unit, the student should be able to: 1. List and describe 3 categories of pipets. 2. List

More information

EXPERIMENT 2. Laboratory Procedures INTRODUCTION

EXPERIMENT 2. Laboratory Procedures INTRODUCTION EXPERIMENT 2 Laboratory Procedures INTRODUCTION Begin each experiment by taking the necessary safety precautions. All materials that will not be used in the lab should be placed out of the laboratory working

More information

EXPERIMENT 1 BASIC LABORATORY TECHNIQUES AND TREATMENT OF DATA MEASUREMENTS

EXPERIMENT 1 BASIC LABORATORY TECHNIQUES AND TREATMENT OF DATA MEASUREMENTS EXPERIMENT 1 BASIC LABORATORY TECHNIQUES AND TREATMENT OF DATA MEASUREMENTS Introduction In the following experiment you will be required to use a Bunsen burner, balance, a pipet, graduated cylinder, flask,

More information

EXPERIMENT 1 TOOLS FOR LAB MEASUREMENT

EXPERIMENT 1 TOOLS FOR LAB MEASUREMENT EXPERIMENT 1 TOOLS FOR LAB MEASUREMENT INTRODUCTION A course in chemistry, one of the physical sciences, differs from a course in, say, literature or history. A main difference is that chemistry usually

More information

Laboratory Activity Measurement and Density. Average deviation = Sum of absolute values of all deviations Number of trials

Laboratory Activity Measurement and Density. Average deviation = Sum of absolute values of all deviations Number of trials Laboratory Activity Measurement and Density Background: Measurements of mass and volume are very common in the chemistry laboratory. The analytical balance is used to measure mass, and the graduated cylinder,

More information

PRE LABORATORY ASSIGNMENT: Lab Section Score: /10 READ THE LAB TEXT BEFORE ATTEMPTING THESE PROBLEMS!

PRE LABORATORY ASSIGNMENT: Lab Section Score: /10 READ THE LAB TEXT BEFORE ATTEMPTING THESE PROBLEMS! EXPERIMENT # 6 Name: PRE LABORATORY ASSIGNMENT: Lab Section Score: /10 READ THE LAB TEXT BEFORE ATTEMPTING THESE PROBLEMS! 1. Calculate the height of a corresponding column of mercury (in mm) that is at

More information

Target Density Lab SCIENTIFIC. Density Inquiry Lab Activities. Introduction. Concepts. Materials. Safety Precautions. Preparation

Target Density Lab SCIENTIFIC. Density Inquiry Lab Activities. Introduction. Concepts. Materials. Safety Precautions. Preparation Target Density Lab Density Inquiry Lab Activities SCIENTIFIC Introduction The concept of density is reinforced as students measure the volume and mass of an unknown liquid in a graduated cylinder, graph

More information

Before you start sampling, be sure to read

Before you start sampling, be sure to read 6. DISSOLVED OXYGEN MONITORING: MONITORING: Using the Titration Method Before you start sampling, be sure to read the following pages to familiarize yourself with the equipment and the procedures that

More information

QAM-I-117 Volumetric Equipment Calibration Verification

QAM-I-117 Volumetric Equipment Calibration Verification 1. Applicability and Purpose This procedure applies to all adjustable and fixed volume pipetters and any labware used to deliver measured volumes of liquid by laboratory analysts at the Texas Institute

More information

Lab Skills Practice: Pipetting Small Volumes. B3 Summer Science Camp at Olympic High School 2016

Lab Skills Practice: Pipetting Small Volumes. B3 Summer Science Camp at Olympic High School 2016 Lab Skills Practice: Pipetting Small Volumes B3 Summer Science Camp at Olympic High School 2016 Pipetter types Serological and micropipettes are used to accurately transfer small liquid volumes (micro-liter

More information

Objective To identify a pure liquid substance using the physical properties of solubility, density, and boiling point.

Objective To identify a pure liquid substance using the physical properties of solubility, density, and boiling point. Chemistry 1020 Identification of an Unknown Liquid Objective To identify a pure liquid substance using the physical properties of solubility, density, and boiling point. Text reference solubility, density,

More information

Gas Laws. Figure 1: Experimental Set-up with Leveling Bulb. GCC CHM 151LL: Gas Laws GCC, 2019 page 1 of 8

Gas Laws. Figure 1: Experimental Set-up with Leveling Bulb. GCC CHM 151LL: Gas Laws GCC, 2019 page 1 of 8 Gas Laws Introduction Although we cannot see gases, we can observe their behavior and study their properties. This lab will apply several concepts from Ideal Gas Laws. You will use your knowledge of chemical

More information

Transferpette -8/-12

Transferpette -8/-12 Transferpette -8/-12 Testing Instructions (SOP) May 2009 1. Introduction The standard DIN EN ISO 8655 describes both the design and the testing of the piston operated pipette Transferpette 8/ 12. The following

More information

Purpose. Introduction

Purpose. Introduction Purpose The objective of this experiment is to determine the density of an unknown liquid and solid. The students will become familiar with the techniques for measuring mass and volume of several samples

More information

Boyle s Law VC 09. Experiment 9: Gas Laws. Abstract

Boyle s Law VC 09. Experiment 9: Gas Laws. Abstract Experiment 9: Gas Laws VC 09 Abstract In this laboratory activity, you will experimentally confirm Boyle s Law, determine absolute zero from Gay-Lussac's Law, and determine the molecular weight of acetone,

More information

The Ideal Gas Constant

The Ideal Gas Constant Chem 2115 Experiment # 8 The Ideal Gas Constant OBJECTIVE: This experiment is designed to provide experience in gas handling methods and experimental insight into the relationships between pressure, volume,

More information

Any laboratory is equipped with specific tools, equipment,

Any laboratory is equipped with specific tools, equipment, Use of Laboratory Equipment and Supplies 3 When you have completed this exercise, you will be able to: 1. Use a balance. 2. Use pipettes and graduated cylinders to measure the volume of liquids. 3. Use

More information

Transferpette. Testing Instructions (SOP) 1. Introduction. May 2009

Transferpette. Testing Instructions (SOP) 1. Introduction. May 2009 Transferpette Testing Instructions (SOP) May 2009 1. Introduction The standards DIN EN ISO 8655 describe both the design and the testing of the piston operated pipette Transferpette. The following Testing

More information

Predicted Dispense Volume vs. Gravimetric Measurement for the MICROLAB 600. November 2010

Predicted Dispense Volume vs. Gravimetric Measurement for the MICROLAB 600. November 2010 Predicted Dispense Volume vs. Gravimetric Measurement for the MICROLAB 600 November 2010 Table of Contents ``Abstract...3 ``Introduction...4 ``Methods & Results...6 ``Data Analysis...9 ``Conclusion...12

More information

Technical Procedure for General Laboratory Equipment

Technical Procedure for General Laboratory Equipment Technical Procedure for General Laboratory Equipment 1.0 Purpose - This procedure specifies the required elements for the use of general laboratory equipment. 2.0 Scope - This procedure applies to all

More information

Additional Reading General, Organic and Biological Chemistry, by Timberlake, chapter 8.

Additional Reading General, Organic and Biological Chemistry, by Timberlake, chapter 8. Gas Laws EXPERIMENTAL TASK Determine the mathematical relationship between the volume of a gas sample and its absolute temperature, using experimental data; and to determine the mathematical relationship

More information

UNCC Biotechnology and Bioinformatics Camp. Dr. Jennifer Weller Summer 2010

UNCC Biotechnology and Bioinformatics Camp. Dr. Jennifer Weller Summer 2010 UNCC Biotechnology and Bioinformatics Camp Dr. Jennifer Weller Summer 2010 Using Micropipettes Lab Intro Micropipettes How do you control volume in the microliter range? How do you verify that the volume

More information

Pipetting Small Volumes

Pipetting Small Volumes Pipetting Small Volumes Introduction Serological and micropipettes are used to accurately transfer small liquid volumes (micro-liter to milli-liter) accurately and precisely. Continuously adjustable Can

More information

Pipetting and Determining Protein Concentration

Pipetting and Determining Protein Concentration Pipetting and Determining Protein Concentration Background Information: When performing experiments in Cell Biology, it is often necessary to use very small volumes of reagents sometimes because the reagents

More information

Determination of the Gas-Law Constant (R) using CO2

Determination of the Gas-Law Constant (R) using CO2 Determination of the Gas-Law Constant (R) using CO2 EXPERIMENT 11 Prepared by Edward L. Brown and Miranda Raines, Lee University The student will become familiar with ideal gases and how their properties

More information

LABORATORY TECHNIQUES. Pouring Liquids

LABORATORY TECHNIQUES. Pouring Liquids LABORATORY TECHNIQUES Working in the chemistry laboratory you will be handling potentially dangerous substances and performing unfamiliar tasks. This section provides you with a guide to the safe laboratory

More information

Aerobic Respiration. Evaluation copy

Aerobic Respiration. Evaluation copy Aerobic Respiration Computer 17 Aerobic cellular respiration is the process of converting the chemical energy of organic molecules into a form immediately usable by organisms. Glucose may be oxidized completely

More information

Inquiry Module 1: Checking the calibration of a micropipette

Inquiry Module 1: Checking the calibration of a micropipette Inquiry Module 1: Checking the calibration of a micropipette 1. Introduction Larger volumes (1mL and more) are usually measured using pipets or measuring cylinders. Such cylinders and pipets are labelled

More information

Chapter Pipette service & maintenance. Pipette specifications according to ISO Repair in the lab or return for service?

Chapter Pipette service & maintenance. Pipette specifications according to ISO Repair in the lab or return for service? Pipette specifications according to ISO 8655 Chapter 5 5.1 The ISO 8655 standard gives the accuracy and precision limits as both absolute and relative values. Specifications will depend on the technique

More information

THE UNIVERSITY OF NEWCASTLE - DISCIPLINE OF MEDICAL BIOCHEMISTRY

THE UNIVERSITY OF NEWCASTLE - DISCIPLINE OF MEDICAL BIOCHEMISTRY THE UNIVERSITY OF NEWCASTLE - DISCIPLINE OF MEDICAL BIOCHEMISTRY Page: 1 of 9 1. Risk Assessment: This risk assessment has been prepared using the National Safety Council of Australia Risk Score Calculator

More information

INTRODUCTION TO THE SPECTROPHOTOMETER AND PIPETTING SKILLS

INTRODUCTION TO THE SPECTROPHOTOMETER AND PIPETTING SKILLS INTRODUCTION TO THE SPECTROPHOTOMETER AND PIPETTING SKILLS Section A: Intro to the spectrophotometer A commonly used instrument in the analysis of cellular extracts is the Spectrophotometer. Today you

More information

Check-In, Lab Safety, Balance and Volumetric Glassware Use, Introduction to Statistics, and MSDS Familiarization

Check-In, Lab Safety, Balance and Volumetric Glassware Use, Introduction to Statistics, and MSDS Familiarization Check-In, Lab Safety, Balance and Volumetric Glassware Use, Introduction to Statistics, and MSDS Familiarization Before coming to lab: Read Chapter 2 of your textbook before coming to lab. This chapter

More information

Figure 1. Example of volume of water required for an unknown sample

Figure 1. Example of volume of water required for an unknown sample Experiment Three Density Procedure Part 1.The density of a solid Obtain a solid unknown sample from your instructor. Write down the number of the unknown in your notebook. Determine the of your unknown

More information

MOLEBIO LAB #1: Microquantity Measurement

MOLEBIO LAB #1: Microquantity Measurement MOLEBIO LAB #1: Microquantity Measurement Introduction: This lab introduces micropipetting and sterile pipetting techniques used throughout this course. Mastery of these techniques is important for good

More information

Standard Operating Procedure. Air Displacement Pipette Calibration

Standard Operating Procedure. Air Displacement Pipette Calibration University of Colorado at Denver October 28, 2003 - Revision 1.00 Page 1 of 7 1 Background: Standard Operating Procedure An accurate pipette is one of the most important tools in performing accurate analytical

More information

Ch. 2: Tools of the Trade

Ch. 2: Tools of the Trade Ch. 2: Tools of the Trade Outline: 2-1 Safety 2-2 Notebook 2-3 Analytical Balance 2-4 Burets 2-5 Volumetric Flasks 2-6 Pipets and Syringes 2-7 Filtration 2-8 Drying 2-9 Calibration of Volumetric Glassware

More information

R: The Ideal Gas Constant Pre-Lab Assignment

R: The Ideal Gas Constant Pre-Lab Assignment R: The Ideal Gas Constant Pre-Lab Assignment Read the entire laboratory investigation and the relevant pages in your textbook, then answers the questions that follow in the space provided below. 1 Describe

More information

Pipettor. User Manual

Pipettor. User Manual Pipettor User Manual Product Code Description Single Chanel Pipettor Variable 550.002.055 Volume 0.5 to 10ul 550.002.060 2 to 20ul 550.002.065 10 to 100ul 550.002.070 20 to 200ul 550.002.075 100 to 100ul

More information

PREPARING GAS SAMPLES IN LARGE PLASTIC SYRINGES

PREPARING GAS SAMPLES IN LARGE PLASTIC SYRINGES PREPARING GAS SAMPLES IN LARGE PLASTIC SYRINGES A wide variety of gases can be prepared safely inside a 60 ml plastic syringe. Here you will practice making carbon dioxide, so that you know the technique

More information

VITLAB Volumetric instruments

VITLAB Volumetric instruments VITLAB Volumetric instruments Standard Operating Procedure (SOP) VITLAB GmbH Linus-Pauling-Str.1 63762 Grossostheim Germany Telefon: +49 6026 97799-0 Fax: +49 6026 97799-30 E-mail: info@vitlab.com Internet:

More information

Experiment 12: MOLAR VOLUME OF AN IDEAL GAS

Experiment 12: MOLAR VOLUME OF AN IDEAL GAS Experiment 1: MOLAR VOLUME OF AN IDEAL GAS Purpose: Determine the molar volume of a gas at standard temperature and pressure (STP, 0 C and pressure of 1 atm) Performance Goals: Collect and measure the

More information

Gas Laws. 2 HCl(aq) + CaCO 3 (s) H 2 O(l) + CO 2 (g) + CaCl 2 (aq) HCl(aq) + NaHCO 3 (s) H 2 O(l) + CO 2 (g) + NaCl(aq)

Gas Laws. 2 HCl(aq) + CaCO 3 (s) H 2 O(l) + CO 2 (g) + CaCl 2 (aq) HCl(aq) + NaHCO 3 (s) H 2 O(l) + CO 2 (g) + NaCl(aq) Gas Laws Introduction: Although we cannot see gases, we can observe their behavior and study their properties. For example, we can watch a balloon filled with helium gas floating in air and conclude that

More information

Transferpette. Testing Instructions (SOP) 1. Introduction. October 1998

Transferpette. Testing Instructions (SOP) 1. Introduction. October 1998 Transferpette Testing Instructions (SOP) October 1998 1. Introduction The standards ISO DIS 8655 and DIN 12650 describe both the design and the testing of the piston operated pipette Transferpette. The

More information

Quantos Automated Dosing Solution Preparation Precise concentrations Process compliance Minimize out-of-specs

Quantos Automated Dosing Solution Preparation Precise concentrations Process compliance Minimize out-of-specs Quantos Automated Dosing Solution Preparation Precise concentrations Process compliance Minimize out-of-specs Gravimetric Sample Preparation The Alternative to Volumetric Flasks From Volumetric to Gravimetric

More information

Experiment 8 GAS LAWS

Experiment 8 GAS LAWS Experiment 8 GAS LAWS FV 6/25/2017 MATERIALS: Amontons Law apparatus, Boyle s Law apparatus, Avogadro s Corollary apparatus, four beakers (2 L), warm-water bath, ice, barometer, digital thermometer, air

More information

Read ENTIRE lab up to Disposal Section. MAKE NOTES!!! **For Procedures, Highlight equipment used and circle quantities measured out.

Read ENTIRE lab up to Disposal Section. MAKE NOTES!!! **For Procedures, Highlight equipment used and circle quantities measured out. Lab Ch 2 Mass, Volume, & Density Lab Partners: READ Prelab!!! Read ENTIRE lab up to Disposal Section. MAKE NOTES!!! **For Procedures, Highlight equipment used and circle quantities measured out. Density

More information

download instant at Experiment 2 A Submarine Adventure: Density Saves the Day

download instant at  Experiment 2 A Submarine Adventure: Density Saves the Day Experiment 2 A Submarine Adventure: Density Saves the Day Instructor Notes and Lab Preparation: Chemicals and Equipment: various metal shapes of copper, nickel, lead, aluminum, brass, iron and magnesium

More information

General Chemistry I Percent Yield of Hydrogen Gas From Magnesium and HCl

General Chemistry I Percent Yield of Hydrogen Gas From Magnesium and HCl Introduction For chemical reactions involving gases, gas volume measurements provide a convenient means of determining stoichiometric relationships. A gaseous product is collected in a long, thin graduated

More information

THERMODYNAMICS OF A GAS PHASE REACTION: DISSOCIATION OF N 2 O 4

THERMODYNAMICS OF A GAS PHASE REACTION: DISSOCIATION OF N 2 O 4 THERMODYNAMICS OF A GAS PHASE REACTION: DISSOCIATION OF N 2 O 4 OBJECTIVES 1. To measure the equilibrium constant, enthalpy, entropy, and Gibbs free energy change of the reaction N2O4(g) = 2 NO2(g). 2.

More information

Analysis of Deuterium Enrichment by Fourier Transform Infrared Spectrometry (FTIR): Practice. Christine Slater PhD

Analysis of Deuterium Enrichment by Fourier Transform Infrared Spectrometry (FTIR): Practice. Christine Slater PhD Analysis of Deuterium Enrichment by Fourier Transform Infrared Spectrometry (FTIR): Practice Christine Slater PhD Nutrition Specialist C.Slater@iaea.org International Atomic Energy Agency Preparation of

More information

RayPette Plus Autoclavable Pipette. User Manual

RayPette Plus Autoclavable Pipette. User Manual RayPette Plus Autoclavable Pipette User Manual CONTENTS 1. YOUR NEW PIPETTE... 1 1.1. Adjustable volume pipettes... 1 1.3 Fully autoclavable... 2 2. UNPACKING... 3 3. INSTALLING THE PIPETTE HOLDER... 4

More information

Gas Laws. 2 HCl(aq) + CaCO 3 (s) H 2 O(l) + CO 2 (g) + CaCl 2 (aq) HCl(aq) + NaHCO 3 (s) H 2 O(l) + CO 2 (g) + NaCl(aq)

Gas Laws. 2 HCl(aq) + CaCO 3 (s) H 2 O(l) + CO 2 (g) + CaCl 2 (aq) HCl(aq) + NaHCO 3 (s) H 2 O(l) + CO 2 (g) + NaCl(aq) Gas Laws Introduction: Although we cannot see gases, we can observe their behavior and study their properties. For example, we can watch a balloon filled with helium gas floating in air and conclude that

More information

The Determination of the Value for Molar Volume

The Determination of the Value for Molar Volume Name AP Chemistry The Determination of the Value for Molar Volume Objective Using a chemical reaction that produces a gas, measure the appropriate values to allow a determination of the value for molar

More information

Eric Sheagley, Lab Supervisor Fall, 2015

Eric Sheagley, Lab Supervisor Fall, 2015 CH 107, Intro to Chemistry Lab Portland State University Eric Sheagley, Lab Supervisor Fall, 2015 Description: CH 107 is the laboratory associated with the CH 104 Intro to Chemistry lecture. Concurrent

More information

Density of Brass: Accuracy and Precision

Density of Brass: Accuracy and Precision Density of Brass: Accuracy and Precision Introduction Density is a measure of a substance s mass-to-volume ratio. For liquids and solids, density is usually expressed in units of g/ml or g/cm 3 ; these

More information

MEASURING VOLUME & MASS

MEASURING VOLUME & MASS MEASURING VOLUME & MASS In this laboratory you will have the opportunity to apply your measuring skills in gathering data, processing it, and interpreting the results. For this experiment you will: 1)

More information

Oct 1, 2002 LAB MANUAL SPECIFIC GRAVITY & ABSORPTION of FINE AGGREGATE AASHTO Designation T 84 (Mn/DOT Modified)

Oct 1, 2002 LAB MANUAL SPECIFIC GRAVITY & ABSORPTION of FINE AGGREGATE AASHTO Designation T 84 (Mn/DOT Modified) Oct 1, 2002 LAB MANUAL 1205.0 1205 SPECFC GRAVTY & ABSORPTON of FNE AGGREGATE AASHTO Designation T 84 (Mn/DOT Modified) 1205.1 GENERAL This test method is intended for use in determining the bulk and apparent

More information

LABORATORY SAFETY EQUIPMENT Final Grade: /45

LABORATORY SAFETY EQUIPMENT Final Grade: /45 LABORATORY SAFETY EQUIPMENT Final Grade: /45 CH.lbSg - Identify, locate, and know how to use laboratory safety equipment including laboratory aprons, lab safety goggles, lab gloves, fire extinguishers,

More information

II. MATERIALS REQUIRED FOR PERFORMANCE TESTING

II. MATERIALS REQUIRED FOR PERFORMANCE TESTING TSP-016 P/N L038-058 4-001 Rev. D February 8, 2000 Page 1 of 14 DISTRIBUTION: VistaLab Technologies Customers EQUIPMENT: MLA Pipettes SUBJECT: Pipette Performance Verification Protocol PURPOSE: To evaluate

More information

Scientific Measurements and Errors: Determination of Density of Glass

Scientific Measurements and Errors: Determination of Density of Glass Experiment Scientific Measurements and Errors: Determination of Density of Glass II Purposes This experiment has three purposes: 1. Making anumber of measurements, including length, weight, and liquid

More information

Intermolecular Forces

Intermolecular Forces Experiment 2 Intermolecular Forces Prepared by Ross S. Nord, Eastern Michigan University with large parts adapted from Chemistry with Computers by Dan D. Holmquist and Donald D. Volz PURPOSE The purpose

More information

Experiment #12. Gas Laws.

Experiment #12. Gas Laws. Goal To observe gas laws in the laboratory. Experiment #12. Gas Laws. Introduction All ideal gases, regardless of molar mass or chemical properties, follow the same gas laws under most conditions. Gas

More information

Research Question How does the concentration of catalase affect the speed of the decomposition reaction of Hydrogen Peroxide into oxygen and water?

Research Question How does the concentration of catalase affect the speed of the decomposition reaction of Hydrogen Peroxide into oxygen and water? Research Question How does the concentration of catalase affect the speed of the decomposition reaction of Hydrogen Peroxide into oxygen and water? Aim To observe the effect of increasing enzyme (catalase)

More information

ASPHALT PLANT LEVEL 1

ASPHALT PLANT LEVEL 1 ASPHALT PLANT LEVEL 1 Module 6: Maximum Specific Gravity FM 1 T 209 FDOT Course Release: 10, Module 6 1 Specification Year: January 2015 The terms Gmm or Maximum Specific Gravity or Rice gravity are often

More information

CHM111 Lab Gas Laws Grading Rubric

CHM111 Lab Gas Laws Grading Rubric Name Team Name CHM111 Lab Gas Laws Grading Rubric Criteria Points possible Points earned Lab Performance Printed lab handout and rubric was brought to lab 3 Safety and proper waste disposal procedures

More information

Standard Practice for Calibration of Laboratory Volumetric Apparatus 1

Standard Practice for Calibration of Laboratory Volumetric Apparatus 1 Designation: E 542 0 Standard Practice for Calibration of Laboratory Volumetric Apparatus This standard is issued under the fixed designation E 542; the number immediately following the designation indicates

More information

TEMPERATURE S RELATIONSHIP TO GAS & VAPOR PRESSURE

TEMPERATURE S RELATIONSHIP TO GAS & VAPOR PRESSURE TEMPERATURE S RELATIONSHIP TO GAS & VAPOR PRESSURE Adapted from "Chemistry with Computers" Vernier Software, Portland OR, 1997 ELECTRONIC LABORATORY NOTEBOOK (ELN) INSTRUCTIONS Read the directions and

More information

The pipettes cover a volume range from 0.1µl to 10ml.

The pipettes cover a volume range from 0.1µl to 10ml. CONTENTS 1. YOUR NEW PIPETTE 1 1.1. Adjustable volume pipettes 1 1.2. Fixed volume pipettes 2 1.3 Fully autoclavable 3 2. UNPACKING 3 3. INSTALLING THE PIPETTE HOLDER 4 4. PIPETTE COMPONENTS 5 5. PIPETTE

More information

CHEMISTRY FACULTY LABORATORY SAFETY CONTRACT CENTRAL CAMPUS

CHEMISTRY FACULTY LABORATORY SAFETY CONTRACT CENTRAL CAMPUS CHEMISTRY FACULTY LABORATORY SAFETY CONTRACT CENTRAL CAMPUS Potential hazards exist in all chemical laboratories and some can cause serious accidents. Fortunately, most accidents can be prevented if each

More information

Experiment 1 Basic Laboratory Operations

Experiment 1 Basic Laboratory Operations Experiment 1 Basic Laboratory Operations INTRODUCTION LECTURE OUTLINE This is the first experiment that most students perform in the laboratory. Oftentimes, the stone is cast in this first laboratory session.

More information

Tex-414-A, Air Content of Freshly Mixed Concrete by the Volumetric Method

Tex-414-A, Air Content of Freshly Mixed Concrete by the Volumetric Method by the Volumetric Method Contents: Section 1 Overview...2 Section 2 Apparatus...3 Section 3 Sampling Requirements...5 Section 4 Procedures...6 Section 5 Calculation...9 Section 6 Archived Versions...10

More information

MassWWP Standard Operating Procedure R-2 Dissolved Oxygen Rev.0 Page 1 of 10

MassWWP Standard Operating Procedure R-2 Dissolved Oxygen Rev.0 Page 1 of 10 MassWWP Standard Operating Procedure R-2 Dissolved Oxygen Rev.0 Page 1 of 10 MassWWP Standard Operating Procedure R-2 Dissolved Oxygen Rev.0 Page 2 of 10 Table of Contents Field Equipment List...3 Sampling

More information

SOLUBILITY OF A SOLID IN WATER

SOLUBILITY OF A SOLID IN WATER 1516L Experiment 2 SOLUBILITY OF A SOLID IN WATER Objectives In this experiment you will determine the solubility of potassium nitrate (KNO 3 ) in water at various temperatures. You will prepare a plot

More information

General Laboratory Rules Graphing Data...13

General Laboratory Rules Graphing Data...13 iii TABLE OF CONTENTS LAB INFORMATION General Laboratory Rules................................. 1 Common Laboratory Equipment............................ 4 Directions for the Laboratory Notebook........................

More information

Lab Session #4 AN Physical Properties

Lab Session #4 AN Physical Properties Lab Session #4 AN Physical Properties The main goal of this laboratory session is to provide a practical experience in the determination of the physical properties for AN and ANFO. The students will determine

More information

Read over Techniques #2, 4, 5, 6, and 9 in the Demonstrations of Nine Practical Lab Techniques booklet.

Read over Techniques #2, 4, 5, 6, and 9 in the Demonstrations of Nine Practical Lab Techniques booklet. Practical Assessment 1 includes: Technique #2 - Use of a Pipette Technique #4 Weighing Technique #5 Use of a Bottle-Top Dispenser Technique #6 Gravity Filtration Technique # 9 Rotary Evaporator Student

More information

Exploring the Properties of Gases. Evaluation copy. 10 cm in diameter and 25 cm high)

Exploring the Properties of Gases. Evaluation copy. 10 cm in diameter and 25 cm high) Exploring the Properties of Gases Computer 30 The purpose of this investigation is to conduct a series of experiments, each of which illustrates a different gas law. You will be given a list of equipment

More information

Quantitative Analysis of Hydrocarbons by Gas Chromatography

Quantitative Analysis of Hydrocarbons by Gas Chromatography Quantitative Analysis of Hydrocarbons by Gas Chromatography Introduction Gas-liquid chromatography (GLC) accomplishes a separation by partitioning solutes between a mobile gas phase and a stationary liquid

More information

SOP No. 14. Recommended Standard Operating Procedure for Gravimetric Calibration of Volumetric Standards Using an Electronic Balance

SOP No. 14. Recommended Standard Operating Procedure for Gravimetric Calibration of Volumetric Standards Using an Electronic Balance OP No. 14 Recommended tandard Operating Procedure for Gravimetric Calibration of Volumetric tandards Using an Electronic Balance 1 Introduction 1.1 Purpose of Test This procedure is a precision mass calibration

More information

CORESTA RECOMMENDED METHOD Nº 67

CORESTA RECOMMENDED METHOD Nº 67 CORESTA RECOMMENDED METHOD Nº 67 DETERMINATION OF WATER IN THE MAINSTREAM SMOKE OF CIGARS BY GAS CHROMATOGRAPHIC ANALYSIS (November 2005) 1. FIELD OF APPLICATION The method is applicable to the particulate

More information

CHEMISTRY 31 INORGANIC QUANTITATIVE ANALYSIS LABORATORY MANUAL

CHEMISTRY 31 INORGANIC QUANTITATIVE ANALYSIS LABORATORY MANUAL CHEMISTRY 31 INORGANIC QUANTITATIVE ANALYSIS LABORATORY MANUAL Spring 2017 Instructor: Roy Dixon Table of Contents EXPERIMENT/EXERCISES PAGES Computer Use 2-9 Laboratory Procedures 10-13 Balances 14-16

More information

Varipette Operating manual

Varipette Operating manual Operating manual Copyright 2013 Eppendorf AG, Hamburg. No part of this publication may be reproduced without the prior permission of the copyright owner. Eppendorf and the Eppendorf logo are registered

More information

The Gas Laws: Boyle's Law and Charles Law

The Gas Laws: Boyle's Law and Charles Law Exercise 6 Page 1 Illinois Central College CHEMISTRY 130 Name The Gas Laws: Boyle's Law and Charles Law Objective The simple laws governing the properties of gases can be readily demonstrated experimentally.

More information