Sizes JNŽ-6, ANŽ-3, ANŽ-4

Size: px
Start display at page:

Download "Sizes JNŽ-6, ANŽ-3, ANŽ-4"

Transcription

1 JNŽ-6, ANŽ-3, ANŽ-4 Application are used in all kinds of low pressure air conditioning, air heating ind ventilation, where it is necesary to equalise the pressure between adjacent rooms. They can be applied where the automatic break of the supply and exhaust air is required after conditioning-, heating- or ventilation device has been turned off. JNŽ-6 ANŽ-3, ANŽ-4 Description consist of supporting frame made of galvanized sheet steel (steel overpressure dampers JNŽ-6) or aluminium section anodised in natural aluminium colour (aluminium overpressure dampers ANŽ-3 and ANŽ-4) and horizontal swinging vanes of sheet aluminium. The horizontal vanes are inserted into plastic bearings, temperature resistant to 80 C. Sealing stripe, attached on lower part of vanes reduces noise. Caution In the cases of effective velocities exceeding the values provided in the diagram of the determination of the total pressure drop on page 298, or in the cases of a likely exposure of the louvres to strong wind gusts, we recommend the installation of a constraint crossbar. JNŽ-6 ANŽ-3 ANŽ-4 / B 1 Sizes All combinations of and according to the table of dimensions are possible. Non-standard dimensions are available on request. Sizes JNŽ-6, ANŽ-3, ANŽ-4 (mm) (mm) n n number of vanes 296

2 Air flow control units Installation 7 VENTILATING GRILLES, VENTILATING VALVES / B 1 Overpressure damper is fastened in built-in frame of angle steel. Designation: JNŽ-6/3 +15 / +15 Overpressure damper is fastened on duct. Connection accessories are not supplied. Designation: JNŽ-6 Combinations of larger overpressure dampers JNŽ-6, ANŽ-3, ANŽ-4: / B 1 38 H2 / B2 35 B = +28 H = +28 B2 = +23 H2 = +23 Overpressure damper is fastened in built-in frame Designation: ANŽ-3/2, ANŽ-4/2 / CIRCULAR DIFFUSERS, SQUARE DIFFUSERS SWIRL DIFFUSERS, VARIABLE SWIRL DIFFUSERS SLOT DIFFUSERS, ROUND DUCT DIFFUSERS H3 B3 B / H AIR DISPLACEMENT UNITS SUPPLY AIR NOZZLES EXTERNAL ELEMENTS H3=(2x)+56 B3=(2x)+56 SOUND ATTENUATORS, SOUND ATTENUATING LOUVRES AIR FLOW CONTROL UNITS 297

3 Pressure drop diagram Use the diagram to determine the total pressure drop in respect of air velocity at the free sectional area. Example of calculation for JNŽ-6, ANŽ-3, ANŽ-4 A ef = x (-10-(13 x n)) in m² where n is a number of vanes. = 500 mm, = 400 mm, n = 5 Q = 2000 m³/h A ef = 500 x ( (13 x 5)) = mm² 0.16 m² v = (Q / 3600) / A ef = (2000 / 3600) / 0.16 = 3.47 m/s Δp cel (Pa) Pressure drop Ordering example Pressure drop pcel (Pa) Steel overpressure damper with installation frame: JNŽ-6/3 x Size: =500 =428 Aluminium overpressure damper with installation frame: ANŽ-4/2 x Size: =500 = Air velocity v (m/s) at the effective area Aef 298

4 Air flow control units Louvre for maintaining the preset pressure difference JNŽ-6W Application The JNŽ-6W louvre for maintaining the preset pressure difference is designed for maintaining the preset pressure difference between two rooms or between indoors and outdoors. Depending on its orientation, the louvre can support overpressure or underpressure. It is a rapid-response precisely adjustable passive element for maintaining the pressure difference and is not airtight. Standard dimensions: from 200x100 to 1000x1000 with 50 mm steps. Other dimensions available upon request. VENTILATING GRILLES, VENTILATING VALVES CIRCULAR DIFFUSERS, SQUARE DIFFUSERS It can be used as an underpressure louvre to prevent the egress of substances (chemicals, smoke, etc.); an overpressure louvre for rooms where preventing the ingress of polluted air is desired; an overpressure valve to prevent the ingress of gases into smokeless areas. Description The blades are interconnected using connecting rods. Precise adjustments are performed on-site. Easy to set up: weights are placed on the threaded rods and secured against unscrewing using nuts SWIRL DIFFUSERS, VARIABLE SWIRL DIFFUSERS SLOT DIFFUSERS, ROUND DUCT DIFFUSERS +76 AIR DISPLACEMENT UNITS Sizes All combinations of and according to the table of dimensions are possible. Non-standard dimensions are available on request. Installation Size JNŽ-6W (mm) (mm) n n number of vanes SUPPLY AIR NOZZLES 38 / B / +15 / B 1 38 EXTERNAL ELEMENTS AIR FLOW CONTROL UNITS SOUND ATTENUATORS, SOUND ATTENUATING LOUVRES 299

5 Pressure drop diagram: Pressure drop pcel (Pa) Iz diagr na pros A = ef Primer = 50 Q = 200 A ef = 50 v = (Q / Example of calculation for JNŽ-6W = 500 mm, = 400mm, n = 5 Q = 2000 m³/h A ef = 500 x ( (13 x 5)) = mm² 0.16 m² v = (Q / 3600) / A ef = (2000 / 3600) / 0.16 = 3.47 m/s Dp cel pressure drop Ordering example Air velocity (m/s) at the effective area A ef Primer n Žaluzija nastavlj Žaluzija nastavlj z vgradn Dimenz [tevilo k DP: Nas Opomb posebe Louvre for maintaining the preset pressure difference JNŽ-6W: JNŽ-6W/DP x Louvre for maintaining the preset pressure difference with installation frame JNŽ-6W/3: JNŽ-6W/3 x Dimensions: =500 =428 DP: Preset pressure difference Note: Value of the desired preset pressure difference must be determined extra by the order. Use the diagram to determine the total pressure drop in respect of air velocity at the free sectional area. A ef = x (-10-(13 x n)) in m² where n is a number of vanes. 300

C O L M A N. Air Distribution SWIRL DIFFUSERS DRS SERIES DRS SERIES

C O L M A N. Air Distribution SWIRL DIFFUSERS DRS SERIES DRS SERIES C O L M N ir Distribution E N G I N E E R E D I R P R O D U C T S SWIRL DIFFUSERS DRS SERIES DRS SERIES D SERIES SWIRL DIFFUSERS pplication The DRS, DQS, DCS and DSS series of fixed circular swirl diffusers

More information

Adjustable swirl diffuser ODZA TECHNICAL DATA

Adjustable swirl diffuser ODZA TECHNICAL DATA Adjustable swirl diffuser ODZA TECHNICAL DATA 2 Adjustable swirl diffuser ODZA Adjustable ceiling swirl diffuser ODZA is intended for commercial and industrial buildings with a large room volume and high

More information

Round duct nozzle jet diffuser Model DSA-RR

Round duct nozzle jet diffuser Model DSA-RR Round duct nozzle jet diffuser Model DSA-RR Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3

More information

A18W35_MASE 130_F_EN MANUAL

A18W35_MASE 130_F_EN MANUAL A18W_MASE 10_F_EN MANUAL CONTENTS 1 Identification 1.1 Manufacturer 1.2 Product name 1. Year of manufacture 1. Area of use 2 Technical specification 2.1 Design 2.2 Function 2. Technical data 2. Security

More information

A17W23_MASE_MUS_EN MANUAL

A17W23_MASE_MUS_EN MANUAL A1W2_MASE_MUS_EN MANUAL CONTENTS 1 Identification 1.1 Manufacturer 1.2 Product name 1. Year of manufacture 1. Area of use 2 Technical specification 2.1 Design 2.2 Function 2. Technical data 2. Security

More information

TECHNICAL DESCRIPTION

TECHNICAL DESCRIPTION TECHNICAL DESCRIPTION Exhaust Hose Reel ser. 865, electric motor driven No. 981118101 Description Limit switches, for hose coiling and uncoiling integrated in drive unit. Motor turns drum via a planetary

More information

CEILING DIFFUSERS technical CONTROL THE AIR YOU BREATHE. types -CD, CAB. Europair Africa a division of Performancair Products Africa (Pty) Ltd

CEILING DIFFUSERS technical CONTROL THE AIR YOU BREATHE. types -CD, CAB. Europair Africa a division of Performancair Products Africa (Pty) Ltd CEILING DIFFUSERS technical types -CD, CAB Europair Africa a division of Performancair Products Africa (Pty) Ltd tel +27 11 974 2425 fax +27 11 974 7251 web www.europair-africa.com email: info@europair-africa.com

More information

CHILLED BEAM FLEXICOOL IQID

CHILLED BEAM FLEXICOOL IQID CHILLED BEAM FLEXICOOL IQID TECHNICAL CATALOGUE 2 Flexicool IQID Chilled beam - Technical catalogue CHILLED BEAM FLEXICOOL IQID The chilled beam Flexicool IQID is an integrated system for ventilation,

More information

Automatic extractor outlet

Automatic extractor outlet L-07-2-01e Automatic extractor outlet Type HFA Contents Application Realisation Operation Safety instructions Contents Application Realisation Operation Safety instructions 2 Connection diagram Dimensions

More information

-4.~1~ S L 0 T D I F F U S E R S

-4.~1~ S L 0 T D I F F U S E R S \ I R DISTR I BUTION SPECIALIST -4.~~ S L 0 T D I F F U S E R S SLSD RLSD Supply Linear Slot Diffuser with hit & miss damper, and with deflectors. Return Linear Slot Diffuser with hit and miss damper,

More information

PRODUCT CONFIGURATOR AT mcr Monsun. smoke extraction and air supply axial-flow fans

PRODUCT CONFIGURATOR AT   mcr Monsun. smoke extraction and air supply axial-flow fans PRODUCT CONFIGURATOR AT WWW.MERCOR.COM.P mcr Monsun smoke extraction and air supply axial-flow fans APPICATION mcr Monsun fans are designed to extract hot air, smoke and exhaust gases from fire-exposed

More information

Turbo Blowers. Combustion Excellence Since Features. Benefits

Turbo Blowers. Combustion Excellence Since Features. Benefits Turbo Blowers Features Integral molded scroll design Turbine bladed impeller Steel inlet guard Precisely balanced impellers eliminate vibration Complete line of available accessories for adapting to any

More information

INSTALLATION & OPERATION MANUAL. Dual Duct VAV Terminals. Redefine your comfort zone.

INSTALLATION & OPERATION MANUAL. Dual Duct VAV Terminals. Redefine your comfort zone. INSTALLATION & OPERATION MANUAL Dual Duct VAV Terminals IOM Dual Duct VAV Terminals IMPORTANT! READ BEFORE PROCEEDING! GENERAL SAFETY GUIDELINES This equipment is a relatively complicated apparatus. During

More information

safety Shut-Off Valve HON 721

safety Shut-Off Valve HON 721 safety Shut-Off Valve HON 7 product information serving the gas industry worldwide safety shut-off valve HON 7 safety shut-off valve HON 7 Application, Characteristics, Technical Data Application safety

More information

Air distribution systems Circular displacement outlet with adjustable damper VA-ZD...

Air distribution systems Circular displacement outlet with adjustable damper VA-ZD... Air distribution systems Circular displacement outlet with adjustable damper VA-ZD... DS 059 E 05.010/1 Construction design and function Preliminary remarks Displacement air outlets enable to extract pollutants

More information

Gas Pressure Regulator HON 300

Gas Pressure Regulator HON 300 Product information serving the gas industry worldwide Applications, characteristics, technical data Applications direct acting gas pressure regulator, for systems in accordance with DVGW working instruction

More information

Supply air diffuser ROFB, RPFB

Supply air diffuser ROFB, RPFB Supply air diffuser ROFB, RPFB ROFB and RPFB are supply air diffusers with an integrated plenum box for freely suspended installation in a ceiling. The diffuser ROFB comes with an unperforated and RPFB

More information

CALMO

CALMO ---------------------------------------------------- Sound attenuator with recessed connection for rectangular ducts ---------------------------------------------------------------------- GENERAL is, due

More information

Louvre panels & grilles. Self-assembly

Louvre panels & grilles. Self-assembly Louvre panels & grilles Self-assembly Installation instructions You can make ventilation grilles to any dimensions you want with a minimum of profiles and accessories. These grilles with slats are made

More information

Vibration isolation system 1VIS10W. User manual

Vibration isolation system 1VIS10W. User manual Vibration isolation system 1VIS10W User manual Standa 2014 Table of contents 1. General information 3 1.1. Introduction 3 1.1.1. Safety 5 1.2. Location of the table 5 1.3. Air supply requirements 5 2.

More information

safety shut-off Valve HON 703 / HON 704

safety shut-off Valve HON 703 / HON 704 safety shut-off Valve HON 703 / HON 704 Product information serving the gas industry worldwide Applications, characteristics, technical data Applications Main safety device in gas pressure regulating systems

More information

HCD HIGH CAPACITY DRUM LOUVER

HCD HIGH CAPACITY DRUM LOUVER HIGH CAPACITY DRUM LOUVER The s (HCD) consist of extruded aluminum blades mounted inside a rotatable drum to produce long air throws with a high degree of directional control. Rotateable drum provides

More information

LindabArchitect. Supply air beam

LindabArchitect. Supply air beam Lindab 01.2018 Lindab Ventilation. All forms of reproduction without written permission are forbidden. is the registered trademark of Lindab AB. Lindab's products, systems, product and product group designations

More information

Slide and Turn System SF25

Slide and Turn System SF25 Profile system Frameless all-glass slide and turn system Option of flush or weathered bottom track Optionally with lateral aluminium panel profiles to close the ventilation gap The flush bottom track is

More information

LindabPremax. Supply air beam. lindab we simplify construction

LindabPremax. Supply air beam. lindab we simplify construction lindab we simplify construction Lindab 03.2016 Lindab Ventilation. All forms of reproduction without written permission are forbidden. is the registered trademark of Lindab AB. Lindab's products, systems,

More information

Bellows actuator EB Key features

Bellows actuator EB Key features Bellows actuator B Bellows actuator B Key features Key features Suitable for use in harsh, dusty ambient conditions Can be used under water Sturdy design Large forces range from 1 50 KN Low installation

More information

4/S8 CONSTANT VOLUME DAMPERS RKP-C, RKP-C-N, RKP-P, KVR-R. v 2.6 (en)

4/S8 CONSTANT VOLUME DAMPERS RKP-C, RKP-C-N, RKP-P, KVR-R. v 2.6 (en) 4/S8 v 2.6 (en) RKP-C, RKP-C-N, RKP-P, KVR-R 294 www.kliaoprea.hr www.kliaoprea.hr 295 INSTAATION RKP-C RKP-C -2... C 5...% rh ±5% set value Working teperature : Relative huidity: Constant flow: 1 x ØD

More information

Krantz Components. Multifunction Sail AVACS. Cooling and Heating Systems

Krantz Components. Multifunction Sail AVACS. Cooling and Heating Systems Multifunction Sail AVACS Cooling and Heating Systems 2 AVACS Air Ventilation And Cooling System 3 System design Air diffuser box Air connection Sound absorbers (optional) Cooling element with heat conducting

More information

Pressure Relief Valve DHV 718

Pressure Relief Valve DHV 718 Pressure Relief Valve DHV 718 Nominal size DN 8 50 Nominal size 3/8 2 Nominal pressure PN 10 bar Features pressure setting range 0.5 to 10 bar diaphragm controlled pressure relief valve simple design,

More information

LindabPremum. Supply air beam. lindab we simplify construction

LindabPremum. Supply air beam. lindab we simplify construction lindab we simplify construction Lindab 03.2016 Lindab Ventilation. All forms of reproduction without written permission are forbidden. is the registered trademark of Lindab AB. Lindab's products, systems,

More information

vento specification sheet

vento specification sheet type purpose application linear diffuser 18mm diffuser for air distribution for false ceiling the diffuser is used for the supply and exhaust of cooled or heated air in facilities such as offices, shopping

More information

Use of Correction Factors When Commissioning Air Systems

Use of Correction Factors When Commissioning Air Systems Shaun Matthews G5 Thesis 24 th January 2016 Rev. 2 Use of Correction Factors When Commissioning Air Systems S. Matthews Grade 5 Thesis - Use Of Correction Factors Rev. 2 1 of 12 Contents Introduction What

More information

HERZ-Motorised flow controler

HERZ-Motorised flow controler HERZ-Motorised flow controler Control and regulating valve Data sheet 46, Issue 214 Dimensions in mm 4 close dimension 9,35 M DN G H1 H2 H2 + Actuator B1 B2 1 2 M 1 46 11 15 3/4 G 66 59 73 134 49 63 48

More information

Safety valves. Component-tested safety valves DN Compressed Air Accessories II Hoses, valves etc. 15. Technical data. Exhaust capacity air

Safety valves. Component-tested safety valves DN Compressed Air Accessories II Hoses, valves etc. 15. Technical data. Exhaust capacity air Component-tested s DN 6 Safety valves serve to blow out non-poisonous and non flammable gases into the atmosphere in order to protect pressure tanks against overpressure. Please note: Only s that have

More information

SF SERIES CNG COMPRESSOR MODEL HF-4MH. 4 Nm3/Hour Displacement OPERATION MANUAL

SF SERIES CNG COMPRESSOR MODEL HF-4MH. 4 Nm3/Hour Displacement OPERATION MANUAL SF SERIES CNG COMPRESSOR MODEL HF-4MH 4 Nm3/Hour Displacement OPERATION MANUAL 1 Content 1. General Description...3 2. Main technical parameters...3 3. Structural principle...4 3.1Main structure...4 3.2Compressor

More information

A17W49_MASEM_F_EN MANUAL

A17W49_MASEM_F_EN MANUAL AW9_MASEM_F_EN MANUAL CONTENTS Identification. Manufacturer. Product name. Year of manufacture. Area of use. Declaration of conformity Technical specification. Design. Function. Technical data. Electrical

More information

for Pleasant & Healthy Air-Distribution ISO 9001:2000 Linear Slot Diffusers Product Bulletin 133-D

for Pleasant & Healthy Air-Distribution   ISO 9001:2000 Linear Slot Diffusers Product Bulletin 133-D for Pleasant & Healthy Air-Distribution ISO 9001:2000 Product Bulletin 133-D Linear Slot Diffusers Pleasant.. Serene.. YOU & DASCO... Since 1964 Partners for good health INTRODUCTION Linear slot diffusers

More information

System 100: 110 x 54mm Rectangular Ducting and Fittings 5 7. System 125: 150 x 70mm Rectangular Ducting and Fittings 8 9

System 100: 110 x 54mm Rectangular Ducting and Fittings 5 7. System 125: 150 x 70mm Rectangular Ducting and Fittings 8 9 British Manufacturing since 1986 Contents Page About Us 4 System 100: 110 x 54mm Rectangular Ducting and Fittings 5 7 System 125: 150 x 70mm Rectangular Ducting and Fittings 8 9 System 150: 180 x 95mm

More information

ARCA cabinet NEW. High performance polycarbonate cabinet. Protection in demanding environments

ARCA cabinet NEW. High performance polycarbonate cabinet. Protection in demanding environments ARCA cabinet NEW High performance polycarbonate cabinet Protection in demanding environments NEW Fibox ARCA Fibox ARCA non corrosive electrical cabinets for use in extremely harsh and demanding environments

More information

GAS PRESSURE CONTROL UNIT TYPE 132

GAS PRESSURE CONTROL UNIT TYPE 132 GAS PRESSURE CONTROL UNIT TYPE 132 OUR DIVERSITY IS YOUR PROFIT. Gas Pressure Regulator Type 132 Scope of Application Scope of type 132 gas pressure regulator is to maintain the output pressure at a constant

More information

MANUAL. Verkstadsvagen 2, SE SKELLEFTEA, Sweden Tel , Fax P17W45_MPREX_F_EN

MANUAL. Verkstadsvagen 2, SE SKELLEFTEA, Sweden Tel , Fax P17W45_MPREX_F_EN MANUAL Verkstadsvagen 2, SE 931 61 SKELLEFTEA, Sweden Tel. +46 910-361 80, Fax. +46 910-130 22 www.fumex.com info@fumex.se P17W45_MPREX_F_EN Contents Important information 3 Applications 3 Technical data

More information

Compact pressure switches for gas and air

Compact pressure switches for gas and air Compact pressure es for gas and air / 5.0 Printed in Germany Edition 0.8 Nr. 9 544 6 Technical description The pressure is an adjustable compact pressure according to EN 854 for combustion plants. The

More information

SafidDampers. Class 1A & Class 1 Low Leakage Volume Control Damper ( Flange Type ) SPK Standard Construction. Description SPK

SafidDampers. Class 1A & Class 1 Low Leakage Volume Control Damper ( Flange Type ) SPK Standard Construction. Description SPK ( Flange Type ) SPK 30 400 Standard Construction FRAME: 60mm x 30mm x.5mm (6 Ga.) galvanized steel formed channel for flange connection. BLADES: 00mm, 5mm and 50mm wide airfoil shaped blades extruded aluminum.

More information

Actuator HON 670 / 671

Actuator HON 670 / 671 Actuator HON 670 / 67 Product information serving the gas industry worldwide Applications, characteristics, technical data Application The actuators HON 670 (K6, K8) and HON 67 (K7) are used to trigger

More information

Production Date of prod. Manufacturer number

Production Date of prod. Manufacturer number Brno Czech Republic Production number Date of prod. Manufacturer 2 Pos. Item name Part no. Pos. Item name Part no. 1 Magazine 5 1207.0001 47 Tripping lever 1207.0140 2 Rod 1207.0002 48 Seat - assembly

More information

SAV. Safety Shut-off Valve. Safety Shut-off Valve Type SAV

SAV. Safety Shut-off Valve. Safety Shut-off Valve Type SAV SAV Safety Shut-off Valve Safety Shut-off Valve Type SAV Direct acting shut-off device with adjustable setpoint springs for over-pressure and underpressure monitoring In compliance with EN 14382 Inlet

More information

Precision pressure regulators LRP/LRPS

Precision pressure regulators LRP/LRPS Precision pressure regulators LRP/LRPS q/w Worldwide: Superb: Easy: Festo core product range Covers 80% of your automation tasks Always in stock Festo quality at an attractive price Reduces procurement

More information

CADENZA

CADENZA ---------------------------------------------- ---------------------------------------------------------------------- Attenuator with aerodynamically shaped splitters for rectangular ducts GENERAL has

More information

Overflow Regulator TYPe 92-99

Overflow Regulator TYPe 92-99 Overflow Regulator TYPe 92-99 Our diversity is your profit. Overflow regulator Type 92-99 Technical data Supply pressure Up to 30 bar Overflow regulators ensure a pressure level, e.g. the discharge pressure

More information

List of Contents vma. Compressed Air Conditioning 2. System description 2. Individual Units Pre-Filters 3. Combinations 6

List of Contents vma. Compressed Air Conditioning 2. System description 2. Individual Units Pre-Filters 3. Combinations 6 Úprava stlačeného vzduchu EWO VMA List of Contents System description Individual Units Pre-Filters 3 Micro-Filters 4 Activated-Charcoal-Filters 5 Combinations 6 Accessories and Main spare parts 6 Service

More information

ZUERCHER TANK REGULATORS PRINCIPLES OF TANK VENTILATION

ZUERCHER TANK REGULATORS PRINCIPLES OF TANK VENTILATION Why Inertisation (blanketing) of Tanks? General Tank inertisation or blanketing is required in many applications where products or liquids stored in the tank are processed and/or filled into and emptied

More information

E Cube Lift Model: ECU Installation Instructions

E Cube Lift Model: ECU Installation Instructions E Cube Lift Model: ECU Installation Instructions 0 E CUBE LIFT INSTALLATION INSTRUCTIONS Please read installation instructions carefully before installation and keep it for future reference. INDEX: Important

More information

Gas Pressure Regulator HON 200

Gas Pressure Regulator HON 200 Product information serving the gas industry worldwide Applications, characteristics, technical data Application Gas supply to municipal, industrial and individual consumers Regulator for low-load rails

More information

Instruction presentation Special valves

Instruction presentation Special valves Instruction presentation Special valves 1 Special Valves 2 Special Valves Index of contents 1. Overview special valves 2. Description Gauge Guard 3. Description Water Jet Pumps 4. Description Venting and

More information

VENTILATOR OPTIONS. Please visit our web page to view all the available options and for a specification.

VENTILATOR OPTIONS. Please visit our web page to view all the available options and for a specification. Seefire Natural Louvred Ventilator Seefire is a natural louvred ventilator that is available in a wide range of sizes, louvre options and control options. Seefire has been exhaustively tested and certified

More information

Chilled beam iq Star WEGA II

Chilled beam iq Star WEGA II Chilled beam iq Star WEGA II Key features Ventilation Water Heating and cooling Adjustable induction Flow Pattern Control In option: Demand Controlled Ventilation, Pressure independent, Electrical heating,

More information

Gas Pressure Regulator HON 502

Gas Pressure Regulator HON 502 Gas Pressure Regulator HON 502 Product information serving the gas industry worldwide Gas Pressure regulator HON 502 Application, Characteristics, Technical Data Application for offtake stations in gas

More information

CLB 3 ATTRACTIVE JOINABLE LINEAR PROFILE EASILY ACCESIBLE VOLUME ADJUSTMENT INCLUDED FLEX CLAMP HEATING AND COOLING TERMINAL REHEAT AVAILABLE

CLB 3 ATTRACTIVE JOINABLE LINEAR PROFILE EASILY ACCESIBLE VOLUME ADJUSTMENT INCLUDED FLEX CLAMP HEATING AND COOLING TERMINAL REHEAT AVAILABLE CONSTANT VOLUME LINEAR BAR CEILING DIFFUSER CLB 3 ATTRACTIVE JOINABLE LINEAR PROFILE EASILY ACCESIBLE VOLUME ADJUSTMENT INCLUDED FLEX CLAMP HEATING AND COOLING TERMINAL REHEAT AVAILABLE CONTROL THE PERIMETER

More information

Ballorex Dynamic Description. Versions. Benefits. Balancing

Ballorex Dynamic Description. Versions. Benefits. Balancing Ballorex Dynamic Description The Ballorex Dynamic valve is a combined pressure independent flow limiter and control valve which maintains a constant flow independently of pressure changes in heating or

More information

Air Differentail Pressure Switch

Air Differentail Pressure Switch Page 1 of 5 PA-DPS-8x Air Differentail Pressure Switch Features: Benefits: Close switching differential Duct fixing kit included Switching point easily adjusted with scale in Pascals Conduit entry can

More information

RTG 311 pressure regulators are included within the direct acting and balanced valve regulator class.

RTG 311 pressure regulators are included within the direct acting and balanced valve regulator class. Introduction RTG 311 pressure regulators are included within the direct acting and balanced valve regulator class. The regulator is used for reducing and regulating the pressure of natural gases and LPG,

More information

Control of Nuclear Gloveboxes and Enclosures Using the No- Moving-Part Vortex Amplifier (VXA)

Control of Nuclear Gloveboxes and Enclosures Using the No- Moving-Part Vortex Amplifier (VXA) Control of Nuclear Gloveboxes and Enclosures Using the No- Moving-Part Vortex Amplifier (VXA) ABSTRACT M.J. Crossley AEA Technology ES. Inc. 1100 Jadwin Ave, Richland, WA 99352, USA This paper describes

More information

CERTIFICATE OF APPROVAL No ME 5088

CERTIFICATE OF APPROVAL No ME 5088 CERTIFICATE OF APPROVAL No ME 5088 1 Unit C, Alexander Bell Centre, Hopkinson Way, West Portway Business Park, Andover, Hampshire, SP10 3UR Tel: 01264 333305 Have been assessed against the requirements

More information

Fire safety of staircases in multi-storey buildings The results of measurements in Buildings and Simulations

Fire safety of staircases in multi-storey buildings The results of measurements in Buildings and Simulations Fire safety of staircases in multi-storey buildings The results of measurements in Buildings and Simulations Grzegorz Kubicki, Ph.D. Department of Environmental Engineering, Warsaw University of Technology

More information

Proportional pressure regulators VPPE

Proportional pressure regulators VPPE Proportional pressure regulators VPPE Proportional pressure regulators VPPE Product range overview Function Version Pneumatic connection Proportional pressure regulator Nominal size for pressurisation/

More information

INDICATIONS FOR CHOICE OF ATEX FANS

INDICATIONS FOR CHOICE OF ATEX FANS INDICATIONS FOR CHOICE OF ATEX FANS CAUTION! ATEX marking is possible only if the fan is assembled by Ferrari or one of its qualified "OBT ATEX" dealers. 1. ATEX SERIES FANS Fan type Category 2 Category

More information

Instruction Manual. Pipe Friction Training Panel

Instruction Manual. Pipe Friction Training Panel Instruction Manual HL 102 Pipe Friction Training Panel 100 90 80 70 60 50 40 30 20 10 HL 102 Instruction Manual This manual must be kept by the unit. Before operating the unit: - Read this manual. - All

More information

IP65 Air Differential Pressure Switch

IP65 Air Differential Pressure Switch Page 1 of 5 PA-DPS-9x IP65 Air Differential Pressure Switch Features: Benefits: Close switching differential IP65 Housing Duct fixing kit included Switching point easily adjusted with scale in One screw

More information

FM Series Low and Medium Velocity Gas, Oil and Combination Burners

FM Series Low and Medium Velocity Gas, Oil and Combination Burners FM Series Low and Medium Velocity Gas, Oil and Combination Burners February 2012 FM Series Features Low or medium velocity burner versions Suitable for liquid or gaseous fuels Simple conversion from gas

More information

Micro grippers HGPM/HGWM

Micro grippers HGPM/HGWM HGPM/HGWM Miniaturised and optimised for assembly tasks Versatile 2004/10 Subject to change Products 2004/2005 1 / 1 HGPM/HGWM Key features HGWM HGPM 1 2 3 4 1 2 3 4 System product for handling and assembly

More information

Liquid ring vacuum pumps in compact design

Liquid ring vacuum pumps in compact design Liquid ring vacuum pumps in compact design LEM 25, LEM 5 Pressure range: Suction volume flow: 33 to 113 mbar 4 to 6 m³/h CONSTRUCTION SIHI liquid ring vacuum pumps are displacement pumps of uncomplicated

More information

Slide and Turn System SF35

Slide and Turn System SF35 Profile system Framed slide and turn system Non-thermally insulated aluminum profiles with insulated glass Option of flush or weathered bottom track The flush bottom track is particularly suitable for

More information

Differential pressure

Differential pressure Differential pressure 9 Overview Page 200 VEGADIF 65 Page 202 Chemical seal Page 204 Accessory Page 208 199 VEGADIF For differential pressure, level and flow measurements Measuring principle The sensor

More information

VARIABLE AIR FLOW REGULATOR

VARIABLE AIR FLOW REGULATOR The RCV regulator is a variable air flow self-regulated system (VAV type). It is used to regulate the air flow in an area or room of a building according to a setpoint. The RCV regulator is also available

More information

for Asia / Pacific Radial outlet RA-N3... DS 4134 AUS /

for Asia / Pacific Radial outlet RA-N3... DS 4134 AUS / for Asia / Pacific Radial outlet RA-N... DS AUS./ Radial outlet RA-N Preliary remarks KRANTZ KOMPONENTEN radial outlets of type RA-N have fixed radial vanes. They generate high-quality, diffuse supply

More information

MULTIFUNCTIONAL CONTROL FOR GAS BURNING APPLIANCE

MULTIFUNCTIONAL CONTROL FOR GAS BURNING APPLIANCE SIT Group SIT -3- SIGMA MULTIFUNCTIONAL CONTROL FOR GAS BURNING APPLIANCE 9.955. Subject to change without notice Application Domestic gas appliances: central heating boilers, combi boilers, instantaneous

More information

SYSTEM REGULATING VALVES PRESSURE RELIEF VALVE - SRV BRASS & S/STEEL ADJUSTABLE

SYSTEM REGULATING VALVES PRESSURE RELIEF VALVE - SRV BRASS & S/STEEL ADJUSTABLE SYSTEM REGULATING VALVES PRESSURE RELIEF VALVE - SRV BRASS & S/STEEL ADJUSTABLE This piston style pressure relief valve with conical shaped needle seat for accurate adjustment is available up to 3 in size.

More information

1800C and 1800C-HC Service Regulators

1800C and 1800C-HC Service Regulators SB 855.9 800C and 800C-HC Service Regulators Maximum Pressure 5 Table of Contents 800C Regulator Information...................... 800C-HC Regulator Information.................. 800C and 8C Service Regulators...............

More information

INDICATIONS FOR CHOICE OF ATEX FANS

INDICATIONS FOR CHOICE OF ATEX FANS INDICATIONS FOR CHOICE OF ATEX FANS CAUTION! ATEX marking is possible only if the fan is assembled by Ferrari or one of its qualified "OBT ATEX" dealers. For the machine technical specifications, refer

More information

Measuring range Δp (span = 100%) Pa

Measuring range Δp (span = 100%) Pa 4.4/ RLE 5: Volume-flow controller, continuous How energy efficiency is improved Enables demand-led volume flow control for the optimisation of energy consumption in ventilation systems. Areas of application

More information

BPB26-1 AND SSPB26-1 PATIO BASE INSTALLATION INSTRUCTIONS

BPB26-1 AND SSPB26-1 PATIO BASE INSTALLATION INSTRUCTIONS BPB26-1 AND SSPB26-1 PATIO BASE INSTALLATION INSTRUCTIONS WARNING: THIS PATIO BASE IS NOT DESIGNED FOR USE WITH AN LP GAS CYLINDER. WARNING: SEE YOUR GRILL OWNER'S MANUAL FOR PROPER LOCATION, MINIMUM CLEARANCES,

More information

CFSW. Hinges with built-in safety multiple switch

CFSW. Hinges with built-in safety multiple switch CFSW. Hinges with built-in safety multiple switch ELESA Original design Elesa Standards Main dimensions Fitting Weight Code Description L B f ±0.2 f 1 ±0.2 H h 1 h 2 d 3 d 4 C [Nm]# g 426601 CFSW.110-6-2NO+2NC-C-A

More information

Technote. Frese PV-SIGMA Compact Dynamic Pressure and Flow Regulation. Description. Application. Operation. Features. Benefits.

Technote. Frese PV-SIGMA Compact Dynamic Pressure and Flow Regulation. Description. Application. Operation. Features. Benefits. Page 1 of 15 Dynamic Pressure and Regulation Description The system is a dynamic valve arrangement designed to regulate flow and differential pressure. Application The system can be installed in both domestic

More information

Fan and air movement essentials

Fan and air movement essentials 1 Properties of air For the purposes of this section we will assume that it is air that will be moved by the various types of fans. The air we breathe is made up of a mixture of gasses - nitrogen 78%,

More information

Liquid ring vacuum pumps in compact design

Liquid ring vacuum pumps in compact design Liquid ring vacuum pumps in compact design, Pressure range: Suction volume flow: 33 to 113 mbar 3 to 58 m³/h CONSTRUCTION TYPE SIHI liquid ring vacuum pumps are displacement pumps of uncomplicated and

More information

LEV Inspection & Test Report

LEV Inspection & Test Report LEV Inspection & Test Report CLIENT: SITE: XXXXXXX LTD XXXXXXX Report Reference: Hinge Room-LEV System Identification: BeCu ESTA Survey Conducted By: Name: Position: Signed: XXXX Environmental Consultant

More information

PNEUMATIC PRESSURE CONTROLLERS

PNEUMATIC PRESSURE CONTROLLERS PNEUMATIC PRESSURE CONTROLLERS VARIABLE VOLUME PRESSURE CONTROLLER MODELS: V-1 R AND V-2R The 3D Variable Volume Pressure Controller is available for requirements of 0-1,000 psi and 0-6,000 psi in absolute

More information

PUBLIC SPA CHECKLIST. Planning and Building Department City of Mississauga 300 City Centre Drive, 3th Floor Mississauga ON L5B 3C1

PUBLIC SPA CHECKLIST. Planning and Building Department City of Mississauga 300 City Centre Drive, 3th Floor Mississauga ON L5B 3C1 Planning and Building Department City of Mississauga 300 City Centre Drive, 3th Floor Mississauga ON L5B 3C1 PUBLIC SPA CHECKLIST This checklist is prepared for purposes of convenience only. For accurate

More information

3M InCa Individual Cross-Connection Cabinets

3M InCa Individual Cross-Connection Cabinets 3M InCa Individual Cross-Connection Cabinets InCa 7/14 InCa 7/12 InCa 7/10 InCa 7/8 InCa 8/14 InCa 8/12 InCa 8/10 InCa 8/8 InCa 10/14 InCa 10/12 InCa 10/10 InCa 10/8 Series 7 Series 8 Series 10 87 The

More information

INSTRUCTION MANUAL Pressure Relief Device LPT

INSTRUCTION MANUAL Pressure Relief Device LPT INSTRUCTION MANUAL Pressure Relief Device LPT 5COV475800 LPT REV00 CONTENT: 1 SAFETY 1.1 Safety instructions 2 1.2 Specified applications 2 1.3 Safety notes on the equipment operation 2 2 PRESSURE RELIEF

More information

6-5 Maintenance Manual

6-5 Maintenance Manual Non Return Valve 6-5 Maintenance Manual Contents 1. PRODUCT DESCRIPTION... 1 1.1 How it works... 1 1.2 Overall dimensions... 3 1.3 Technical datasheet... 4 1.3.1 Push flow situation... 4 1.3.2 Pull flow

More information

Operating instructions Pressure sensor. PN422x / / 2013

Operating instructions Pressure sensor. PN422x / / 2013 Operating instructions Pressure sensor PN422x 80002606 / 00 11 / 2013 Contents 1 Preliminary note...3 1.1 ymbols used...3 2 afety instructions...3 3 Functions and features...3 4 Function...5 4.1 witching

More information

VARIABLE ORIFICE BALANCING VALVE PN 25 TECHNICAL DATA SHEET. Approved by*: Main features:

VARIABLE ORIFICE BALANCING VALVE PN 25 TECHNICAL DATA SHEET. Approved by*: Main features: VARIABLE ORIFICE BALANCING VALVE PN 787 Main features: Technical data: Cim 787 is used for balancing the flow in cooling, heating and domestic water systems. Cim 787 is a combined manual presetting valve

More information

INSTALLATION, OPERATION AND MAINTENANCE GUIDE

INSTALLATION, OPERATION AND MAINTENANCE GUIDE INSTALLATION, OPERATION AND Placement in Pipeline System When installing Process Development & Control s ElastoTITE Elastomer-Hinged Check Valves in a pipeline, a minimum of five pipe diameters should

More information

Product: Aluminium Door Edge Guard

Product: Aluminium Door Edge Guard : : DEB-44-AA 44mm Square profile, brush and intumescent DEB-46-AA 46mm Square profile, brush and intumescent DEB-55-AA 55mm Square profile, brush and intumescent DEE-45-AA 45mm Rounded profile, longer

More information

Pressure Regulator 133 / 233

Pressure Regulator 133 / 233 Benefits Accurate regulation Exchangeable component technique Easy maintenance Suitable for HTB requirements DVGW-approval (DIN 3380/81, VP 200). Description The 133/233 regulator is a direct-acting, spring

More information

Wide opening parallel grippers Series CGLN

Wide opening parallel grippers Series CGLN CATALOGUE > s 202 Wide opening parallel grippers Series CGLN > Grippers Series CGLN Magnetic Sizes: ø 0-6 - 20-25 - 32 mm» High flexibility during mounting» High grip force» Rack and pinion synchronized

More information

TABLE OF CONTENTS SAFETY FIRST!...3 BASIC OPERATION...4 ADJUSTMENTS...5. Cocking Pressure...5. Three-Way Valve Adjustment...6

TABLE OF CONTENTS SAFETY FIRST!...3 BASIC OPERATION...4 ADJUSTMENTS...5. Cocking Pressure...5. Three-Way Valve Adjustment...6 TABLE OF CONTENTS SAFETY FIRST!...3 BASIC OPERATION...4 ADJUSTMENTS...5 Cocking Pressure...5 Three-Way Valve Adjustment...6 External Three-Way adjustment...6 In-Line Regulator...6 Ram to Cocking Block

More information

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1 Dry 131h 1. DESCRIPTION The Viking Model G-1 Maintenance Air Compressor is an electric motor-driven, aircooled, single-stage, oil-less compressor. The unit is equipped with a check valve and provides a

More information

Valves, manually operated

Valves, manually operated Valves, manually operated Valves, manually operated Key features VHEM-P K/O-3-PK-3 H-3-¼-B KH/O-3-PK3 TH/O-3-PK3 F-3-¼-B Innovative Versatile Reliable Easy to mount Small and compact for a wide range of

More information