OVERVIEW OF THE CONVAL 10 SERVICE RELEASES
|
|
- Loreen Casey
- 5 years ago
- Views:
Transcription
1 OVERVIEW OF THE CONVAL 10 SERVICE RELEASES CHANGES IN BUILD Fixes of stability issues when exporting calculations Sound level corrections in downstream resistance structures were not taken into account in the other operating points. CHANGES IN BUILD Improved handling for calculation templates User-defined fields have the option whether they should be displayed in the minus view or not. The CONVAL help system was blocked for network installations by a Windows security update. Access is now possible again by updating the CONVAL Client installation. Various problems with changing the display language have been fixed. Small improvements in exporting and printing multiple calculations An additional correction field for the noise reduction by a sound-insulated pipe was added. Nominal pressure ratings with pressure-temperature curves also according to ASME B16.34 were added. DIFFERENTIAL PRESSURE FLOW ELEMENT The new edition of ISO TR 15377: is supported. "Measurement of fluid flow by means of pressure-differential devices - Guidelines for the specification of orifice plates, nozzles, and Venturi tubes beyond the scope of ISO 5167" Compared to the withdrawn standard the following amendment has been made: Improved calculation of drain holes through the upstream face of the square-edged orifice plate CONVAL checks whether orifices must be provided with an outlet bevel. The uncertainty calculation of orifice plates with drain holes has been corrected. New export templates for pressure relief valves have been added. Extended filter options are available for valve selection During the plausibility check, the maximum set pressure was incorrectly compared with the relieving pressure and not with the set pressure. RUPTURE DISC Extended plausibility check for the maximum allowable working pressure MAWP for calculation according to ASME / API. Improved handling of calculations with a burst pressure below 15 psi PAGE 1
2 THERMOWELL PRESSURE LOSS PIPE WALL THICKNESS The edition of DIN 2413: is supported. Seamless steel tubes for oil- and water-hydraulic systems - Calculation rules for pipes and elbows for dynamic loads The practical application of DIN EN showed that this standard can lead to wall thicknesses for hydraulic systems that are too great according to many years of experience. It was therefore necessary to define a different calculation method. Compared to the withdrawn standard the following amendments have been made: the scope has been limited to seamless carbon and stainless steel pipes and elbows for oil and water hydraulic systems not covered by Pressure Equipment Directive 97/23/EC the material properties have been changed Scope II Pipelines for predominantly static loads above 120 C Calculation temperature is no longer the subject of this standard (see DIN EN ) CHANGES IN BUILD Possible security issues in the Sentinel License Manager SACC have been resolved by updating to runtime version 7.80 ( ). An error in the conversion of power with the units kj/h, J/h has been fixed. CHANGES IN BUILD Automatic log out from network licenses when inactive. during parameter search Problems with printing headers, footers, and calculation messages are fixed. Administrators have the possibility to prevent the update of device and substance databases as well as the application of license updates. Issues with export to Excel templates are fixed. Addition of design data for pressure and temperature testing for materials of body and pipelines. An issue in the calculation of the outlet velocity of valves with additional stages in the valve has been addressed. Revised reliability analysis of large valves and when using abrasive media DIFFERENTIAL PRESSURE FLOW ELEMENT The uncertainties in the flow rate table are always calculated with the absolute uncertainty of the differential pressure. Extension of the range for the diameter ratio β of orifice plates according to ISO/TR to 0.23 < β < 0.7. PAGE 2
3 Revised calculation of compressible media at critical flow conditions according to Richard W. Miller "Flow Measurement Engineering Handbook". The alternative calculation of steam according to ISO 4126 and AD 2000-A2 using the steam pressure coefficient is supported. Addition of design data for pressure and temperature testing for materials of body and pipelines. Revised calculation of discharge conditions for compressible media. TANK DEPRESSURIZATION In most cases, the simulation in the tank depressurization module terminated without result. SHELL AND TUBE HEAT EXCHANGER The calculation of the mass flow in the tubes of the heat exchanger when entering the mass or volume flow in the jacket was incorrect under certain circumstances. SUBSTANCE CALCULATION Minor improvements in the calculation of gas and liquid mixtures COM-SERVER New parameter for the COM server to check the standard conformity of thermowells Problems with the registration of the COM server are fixed. Problems with the processing of gas and liquid mixtures have been solved. CHANGES IN BUILD LICENSING Access to license servers via an alias name is possible again. CHANGES IN BUILD EXPORT For PDF export, additionally to the solution integrated in CONVAL 10 also the formerly in CONVAL 9 used CONVAL PDF interface is supported again, which produces higher compressed PDF documents. An issue, which in rare cases prevented the export into the MS Excel-Format, is addressed. - LICENSING The license check of network installations is more tolerant towards short-time connection interruptions. The license search and the port test over IPv6 were improved. An issue, which in rare cases caused a delayed program start with message Sentinel key not found (H0007, is addressed. PROPERTY CALCULATION The calculation of the standard conditions data (density and real gas factor) for substances from the optional thermodynamics package was revised. More reliable check of the triple point temperature for media from the optional thermodynamics package. PAGE 3
4 Improved behavior at the calculation of very viscous substances in calculations, where the valve size was not entered yet Improved stability in conjunction with downstream resistances STEAM CONDITIONING VALVE An issue with the calculation of the additional working points of water injection valves is addressed. For better comparability with old calculations, the prediction of choked flow conditions in CONVAL 10 with use of the legacy calculation method was adapted to the method of the last published CONVAL 9 version (Build ). PRESSURE SURGE An issue, which led to an access violation when opening the valve selection dialog, is addressed. COM SERVER You can create and edit gas and liquid mixtures with the COM server now. CHANGES IN BUILD STEAM CONDITIONING VALVE An issue, which led to an access violation at the start of the module, is addressed. At the calculation of the residual pressure loss of multi-hole orifices with compressible media, the test of critical flow conditions was not always performed correctly when the number of holes was decreased. Improved forecast of possible piping damage at critical flow conditions The calculation of the pressure loss in the discharge pipe of relief valves has been revised. The pressure loss of short discharge pipes with extensions was calculated too small at compressible flow. However, the calculation of the permissible pipe length - and thus the testing of the standard conformity was correct. CHANGES IN BUILD Language support for English, French, and German (further languages will come) CHANGES IN BUILD Various issues with the print preview and with the PDF export, like for example missing identifiers or wrong font sizes, are addressed. Various issues when changing the program language are addressed. In some cases the option "Gas, dry (Standard conditions)" is missing in the selection list. PAGE 4
5 Alternatively input of the hole diameter or the number of flow passages of the valve trim with control valves with multi-hole trim design Improved forecast of possible piping damage with resistance structures at critical flow conditions An issue with the calculation of the valve authority (Δp100/Δp0) of valves with resistance structures and compressible media is addressed. Revised reliability prediction for multi-stage valves with compressible media Revised filter mechanism for the nominal size in the valve selection dialog In some cases the calculation of the operating characteristics fails if calculations are performed without thermodynamics package and the mass flow rate qn is entered. DIFFERENTIAL PRESSURE FLOW ELEMENT The uncertainty of the discharge coefficient C is estimated for non-standard conditions. Improved accuracy of the stress calculation of orifices with materials, for which not all properties are present in the database The maximum pipe roughness with orifices according to ISO 5167:1995/A1: 1998 were calculated falsely following the ISO 5167 edition of The calculation of the throttle orifice d gives incorrect results in some cases. At calculations with input of the pressure difference Δp following the old calculation method of CONVAL 9 the residual pressure loss Δϖ could not be entered any longer after switching to the new calculation method of CONVAL 10. In rare cases the print-out contained inappropriate messages, which do not arise in the calculation form. Beside the rated mass flow now also the rated volume flow is shown. THERMOWELL The uncorrected fatigue stress limit was not displayed correctly using thermowells with mounting type Socket according to ASME PTC 19,3 TW In very rare cases the natural frequency of thermowells according to DIN was not calculated correctly. RUPTURE DISC Calculation of the reaction force according to API 520 or ISO 4126 CONDENSER Condensers can be designed and calculated not only for saturated steam but also for overheated steam. OVERVIEW OF THE INNOVATIONS IN CONVAL 10 Defaults for calculation standard and pipe class in the program options Flange / tubing dimensions according to ASME B16.5 and EN Extended material database with improved selection options Automatic online update of all device and material databases Revised online help system PAGE 5
6 PROPERTY CALCULATION The new thermodynamics package consists of three components: FLUIDCAL FLUIDCAL is integrated in CONVAL to perform the calculation of thermodynamic properties from equations of state (fundamental equations in the form of the Helmholtz free energy). This program enables the user to calculate more than 25 thermodynamic properties of more than 70 substances. For a large number of substances the most common transport properties can also be calculated. NIST REFPROP REFPROP is an acronym for reference fluid properties describing a program which calculates the thermodynamic and transport properties of industrially important fluids and their mixtures. The program embeds pure substances and predefined or user defined fluid mixtures and represents the substance calculation with the highest accuracy in this context. GERG 2008 Calculation of mixtures according to GERG The GERG-2008 equation is valid in the gas phase, in the liquid phase, in the supercritical region and for the vapor-liquid equilibrium. Extended calculation of resistance structures Design (automatic) CONVAL calculates all intermediate pressures between the single resistances and optimizes them. Design (specify pressures) Specification of the intermediate pressures and the subsequent calculation of the resistance structure Recalculation (specify Cv) Recalculation of an existing single or multi stage multi hole orifice plate configuration Noise calculation Analysis of the resistances of all operating points Improved sound prediction Calculation according IEC (2015) Calculation of the sound pressure level at each third octave frequency for all operating points Support of body materials with pressure and temperature curves Improved selection of valves with extended filter possibilities Support of liquids containing dissolved gas Improved calculation of super-critical fluids (isentropic exponent ϰ > 1,6) Revised reliability forecast for multi-stage valves Optional input of the distinct mass flows of the liquid and vapor phase for two-phase flow STEAM CONDITIONING VALVE Beside water many other media from the new thermodynamics module can be computed. DIFFERENTIAL PRESSURE FLOW ELEMENT Revised selection of measuring devices and calculation standards Supported flow elements: Orifices Nozzles Venturi PAGE 6
7 Averaging pitot tubes Cone meter Wedge flow meter Integral flow orifice assembly Manufacturer dependent special designs Supported calculation bases: ISO 5167 (2003, 1998, 1995, 1980) ISO (2016) ISO/TR (2007) ISO 9300 (2005) ASME MFC-3Ma (2007) ASME MFC-7 (2016, 1987-R2014) ASME MFC-14M (2003) ASME PTC 6 (2004) ASME PTC 19.5 (2004) AGA 3 / API MPMS 14.3 (2013, 2003) VDI/VDE 2041 (1991) R. W. Miller, Flow Measurement Engineering Handbook (1996) Clear summary of all limitations of use Stress calculation for orifices (ASME 31,3/AD 2000/ISO 5167 etc.) Clear arrangement of the required inlet and outlet sections Revised uncertainty calculation Calculation of segmental orifices with carrier rings Improved calculation method considering the length of the cylindrical orifice Support for multi-hole orifices Revised forecast of choked-flow conditions Improved stress calculation (ASME 31,3/AD 2000/ISO 5167 etc.) Improved sound prediction Calculation of the Vena Contracta and outlet conditions Support of liquids containing dissolved gas PRESSURE LOSS Support of two-phase flow conditions according to three different calculation methods: L. Friedel Improved friction pressure drop correlation for horizontal and vertical two phase pipe flows European two phase flow group meeting, Ispra, 5-8 June 1979 H. Müller-Steinhagen K. Heck A Simple Friction Pressure Drop Correlation for Two-Phase Flow in Pipes Chem. Eng. Process., 20 (1986) Homogeneous flow model Enhanced flow resistance database according to I. E. ldel'chik HANDBOOK OF HYDRAULIC RESISTANCE PAGE 7
8 Supported calculation standards: ISO (2013) ISO AMD 1 (2016) ISO (2008) API 520 (2014) API 521 (2014) API 526 (2009) ASME Section VIII (2011) AD Specification A2 (2015) THERMOWELLS Supported calculation standards: DIN (2000) For standardized and variable forms with up to three sections ASME PTC 19.3 TW (2016) With graphical stress analysis ASME PTC 19.3 (1974) LEVEL CALIBRATION Calculation of the uncertainty of the relative level in dependence of the densities in the legs (For example to check the influence of the ambient temperature with tanks with two liquids) PAGE 8
CONVAL HISTORY 07/09/2012
OVERVIEW OF THE CONVAL 8 SERVICE RELEASES Starting from version 8.0.3 CONVAL is compatible to Microsoft Windows 7 (32 and 64-bit). CHANGES IN BUILD 8.0.6 MISCELLANEOUS Revised: Now all messages - including
More informationOperational Settings:
instrucalc features more than 70 routines associated with control valves, ISO flow elements, relief valves and rupture disks, and calculates process data at flow conditions for a comprehensive range of
More informationDimensioning of Safety Valves Auditorium Tecnimont
Dimensioning of Safety Valves Auditorium Tecnimont 21.09.2016 Objective of the presentation Design of Safety Valves ASME VIII / API 520 The objective of the presentation is to show the design of safety
More informationRestriction Orifice. Single or Multi Stage Orifice to. Reduce Pressure or. Limit the Flow Rate
Restriction Orifice Single or Multi Stage Orifice to Reduce Pressure or Limit the Flow Rate Restriction Orifice Plates Series ROPS Principle Restriction Orifice Plates and Critical Flow Devices and their
More informationModeling a Pressure Safety Valve
Modeling a Pressure Safety Valve Pressure Safety Valves (PSV), Pressure Relief Valves (PRV), and other pressure relieving devices offer protection against overpressure in many types of hydraulic systems.
More informationREFERENCE GUIDE. Rev. 0 15/09/2016
VALVE SIZING CALCULATOR REFERENCE GUIDE Rev. 0 15/09/2016 Copyright HIT VALVE S.p.A. 2016 All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted,
More informationImpact of imperfect sealing on the flow measurement of natural gas by orifice plates
Impact of imperfect sealing on the flow measurement of natural gas by orifice plates Rubens Silva Telles 1, Kazuto Kawakita 2 1 IPT Instituto de Pesquisas Tecnológicas, São Paulo, Brazil, rtelles@ipt.br
More information44 (0) E:
FluidFlow Relief Valve Sizing Handbook Flite Software 2016 Flite Software N.I. Ltd, Block E, Balliniska Business Park, Springtown Rd, Derry, BT48 0LY, N. Ireland. T: 44 (0) 2871 279227 E: sales@fluidflowinfo.com
More informationThe Discussion of this exercise covers the following points:
Exercise 3-2 Orifice Plates EXERCISE OBJECTIVE In this exercise, you will study how differential pressure flowmeters operate. You will describe the relationship between the flow rate and the pressure drop
More informationProSoft Technology, Inc. Summary Regarding Alberta Energy and Utilities Board Directive 017 of May 2007
Overview ProSoft Technology, Inc. Summary Regarding Alberta Energy and Utilities Board Directive 017 of May 2007 ProSoft Technology s Gas and Liquid Flow Computer (AFC) products will comply with the requirements
More informationOrifice plate, model FLC-OP Orifice flange, model FLC-FL Annular chamber, model FLC-AC
Flow measurement Orifice plate, model FLC-OP Orifice flange, model FLC-FL Annular chamber, model FLC-AC WIKA data sheet FL 10.01 Applications Power generation Oil production and refining Water treatment
More informationMeasurement & Analytics Wet gas monitoring
Product guide PG/FLOW/010-EN Measurement & Analytics Wet gas monitoring Economical wet gas metering using non-proprietary correlations Measurement made easy Introduction With many of the most economically
More informationThis portion of the piping tutorial covers control valve sizing, control valves, and the use of nodes.
Piping Tutorial A piping network represents the flow of fluids through several pieces of equipment. If sufficient variables (flow rate and pressure) are specified on the piping network, CHEMCAD calculates
More informationMass Flow Controller (MFC) for Gases
Mass Flow Controller (MFC) for Gases Type 8713 can be combined with... Direct flow measurement by MEMS- Technology for nominal flow rates from 1 ml N /min to 8 l N /min (N 2 ) High accuracy and repeatability
More informationApplication Worksheet
Application Worksheet All dimensions are nominal. Dimensions in [ ] are in millimeters. Service Conditions Medium Through Valve: Required C v : Temperature Maximum: Minimum: Normal: Flow Maximum: Minimum:
More informationTutorial. BOSfluids. Relief valve
Tutorial Relief valve The Relief valve tutorial describes the theory and modeling process of a pressure relief valve or safety valve. It covers the algorithm BOSfluids uses to model the valve and a worked
More informationBACK PRESSURE / SUSTAINING
In many liquid piping systems, it is vital that line pressure is maintained within relatively narrow limits. This is the function of the 108 Pressure Relief / Back Pressure Series of the OCV control valves.
More informationMass Flow Controller (MFC) for Gases
Mass Flow Controller (MFC) for Gases Bypass MFC with capillary technology for nominal flow rates from 5 ml N /min to 15 l N /min Applicable for aggressive gases Compact design and digital communication
More informationBACK PRESSURE / SUSTAINING
SPECIFICATIONS DIMENSIONS In many liquid piping systems, it is vital that line pressure is maintained within relatively narrow limits. This is the function of the 108 Pressure Relief / Back Pressure Series
More informationMounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25
Self-operated Pressure Regulators Differential Pressure Regulators (opening) Type 42-20 Type 42-25 Type 42-20 Differential Pressure Regulator Type 42-25 Differential Pressure Regulator Mounting and Operating
More informationSelf-operated Pressure Regulators for special applications
Self-operated Pressure Regulators for special applications Type 2357-31 Pressure Build-up Regulator with safety function and integrated excess pressure valve Application Pressure regulators for cryogenic
More informationPressure and Flow Control Valves DBGM, German and European Patents
Pressure and Flow Control Valves DBGM, German and European Patents Absolutely Reliable Pressure and Flow Control In water mains of sizes DN 50 to DN 150, ERHARD Control Valves in straight or angle pattern
More informationCOMPAFLOW. Compressed Air. Volumetric flow. Gas. Mass flow. Steam. Net volumetric flow. Liquid
Volumetric flow Compressed Air Mass flow Gas Net volumetric flow Steam Liquid Universal compact orifice flow meter combines a compact orifice flow sensor and sotiphicated converter One-piece flow sensor,
More informationMAKING MODERN LIVING POSSIBLE. Pilot operated internal safety valves type POV REFRIGERATION AND AIR CONDITIONING DIVISION.
MAKING MODERN LIVING POSSIBLE Pilot operated internal safety valves type POV REFRIGERATION AND AIR CONDITIONING DIVISION Technical leaflet Contents Page Introduction...3 Features...3 Design...4 Technical
More informationHANDBOOK SAFETY DEVICES. Ed SAFETY DEVICES DS-ED 01/ ENG 1
HANDBOOK Ed. 2017 DS-ED 01/2017 - ENG 1 CHAPTER 9 BURSTING DISC DEVICES IN SERIES 3070 SCOPE Use: protection against possible overpressure of the apparatuses listed below, with regard to the operating
More informationSteam generator tube rupture analysis using dynamic simulation
Steam generator tube rupture analysis using dynamic simulation Heat Exchangers are used to transfer heat from a hot fluid to a cold fluid. Most of the times these fluids are available at different pressures
More informationSIDRA INTERSECTION 6.1 UPDATE HISTORY
Akcelik & Associates Pty Ltd PO Box 1075G, Greythorn, Vic 3104 AUSTRALIA ABN 79 088 889 687 For all technical support, sales support and general enquiries: support.sidrasolutions.com SIDRA INTERSECTION
More informationA REVIEW OF THE 2000 REVISIONS TO ANSI 2530/API MPMS 14.3/AGA REPORT NO. 3 - PART2 Paul J. LaNasa CPL & Associates
A REVIEW OF THE 2000 REVISIONS TO ANSI 2530/API MPMS 143/AGA REPORT NO 3 - PART2 Paul J LaNasa CPL & Associates PO Box 801304, Houston, TX 77280-1304 ABSTRACT Periodically, natural gas measurement standards
More information1 PIPESYS Application
PIPESYS Application 1-1 1 PIPESYS Application 1.1 Gas Condensate Gathering System In this PIPESYS Application, the performance of a small gascondensate gathering system is modelled. Figure 1.1 shows the
More informationMounting and operating instructions EB 2530 EN. Self-operated Pressure Regulator. Pressure Reducing Valve Type M 44-2
Self-operated Pressure Regulator Pressure Reducing Valve Type M 44-2 Type M 44-2, connection G 1 4, K VS = 0.15 Type M 44-2, connection G 1, K VS = 6 Fig. 1 Type M 44-2 Pressure Reducing Valve Mounting
More informationCOMMITTEE DRAFT. API 520 Part I 10 th Edition Ballot Item 2.1. This ballot covers the following item:
This ballot covers the following item: API 520 Part I 10 th Edition Ballot Item 2.1 2008 12 Modify guidance to PRV datasheets (Line 17) to assist user s with determining the temperature to use for selecting
More informationHUMOR 20. High-precision Humidity Calibrator HUMOR 20. Operation
High-precision Humidity Calibrator The role of humidity calibrations that are accurate, reproducible, and documentable is becoming more and more important. ISO quality guidelines and regulations according
More informationThis document is a preview generated by EVS
INTERNATIONAL STANDARD ISO 5167-5 First edition 2016-03-01 Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full Part 5: Cone meters
More informationMass Flow Meter (MFM) for Gases
873 Mass Flow Meter (MFM) for Gases Direct flow measurement by MEMS- Technology for nominal flow rates from 1 ml N /min to 8 l N /min (N 2 ) High accuracy Short response time Compact design and digital
More informationWelcome to the LESER Seminar, Taipei 28. June Design_of_safety_relief_valves_250804_Cal
Welcome to the LESER Seminar, Taipei 28. June 2006 1 Design of safety relief valves 2 Design of safety valves Target Classification of Pressure Relief Devices General design of Safety Relief valves 3 Design
More informationGA24 Technical Datasheet
GA24 Technical Datasheet Variable-area flowmeter Sturdy construction for several applications Local indication without auxiliary power Replaceable mounting parts KROHNE CONTENTS GA24 1 Product features
More informationFLOW MEASUREMENT WITH ORIFICES. Types: BLS500 / BLS550
FLOW MEASUREMENT WITH ORIFICES Types: BLS500 / BLS550 Technical Information International Headquarters: Sales Office for the Benelux: Intra-Automation GmbH B.V. Intra-Automation HTP Otto-Hahn-Str. 20 PO
More informationOperational Behaviour of Safety Valves with Constant Superimposed Backpressure
Operational Behaviour of Safety Valves with Constant Superimposed Backpressure Arne Gastberg Albert Richter ARI-Armaturen GmbH & Co. KG When selecting spring loaded safety valves, an accurate knowledge
More informationPTF4 Pivotrol Pump (patented) version Dual Mechanism - Pressure Powered Pump
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
More informationTransient Analyses In Relief Systems
Transient Analyses In Relief Systems Dirk Deboer, Brady Haneman and Quoc-Khanh Tran Kaiser Engineers Pty Ltd ABSTRACT Analyses of pressure relief systems are concerned with transient process disturbances
More informationCash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified
Cash Valve PILOT OPERATED BACK PRESSURE VALVE ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 01 Certified KP HIGH CAPACITY PILOT OPERATED BACK PRESSURE VALVE DESCRIPTION The Cash Valve Type KP is a pilot
More informationMounting and Operating Instructions EB 3017 EN. Self-operated Regulators
Self-operated Regulars Flow and Differential Pressure Regular Type 42-37 Flow and Differential Pressure or Flow and Pressure Regular Type 42-39 Type 42-37 Type 42-39 Fig. 1 Flow and differential pressure
More informationASX 176 Axial Pressure regulator
ASX 176 Axial Pressure regulator ASX 176 Classification and Area of Application ASX 176 is a downstream pressure regulator, pilot controlled, for medium and high pressure applications. It is particularly
More information2-Port Seat Valves with Flange, PN 16
4 45 2-Port Seat Valves with Flange, PN 6 VVF45... dular cast iron EN-GJS-400-5 valve body DN 50...50 k vs 9...00 m /h Can be equipped with SKB...- or SKC...- electrohydraulic actuators Use For use in
More informationDesign. Pompetravaini-NSB API SB Liquid Ring Compressor for Gas Processing. Working Principle
SB Pompetravaini-NSB API SB Liquid Ring Compressor for Gas Processing A family of API liquid ring compressors has been developed and has been in the market for nearly a decade, they are specifically made
More informationSizing, Selection, and Installation of Pressure-relieving Devices in Refineries
Sizing, Selection, and Installation of Pressure-relieving Devices in Refineries Part I Sizing and Selection Downstream Segment API STANDARD 520 EIGHTH EDITION, DECEMBER 2008 Special Notes API publications
More informationDK46 - DK800 Supplementary instructions
DK46 - DK800 Supplementary instructions Variable area flowmeter Device category II2G with electrical internals Additional Ex manual KROHNE CONTENTS DK46 - DK800 1 Safety instructions 3 1.1 General... 3
More informationBall Float Steam Trap UNA 43 PN 16/CL 125/JIS 10K UNA 46 PN 40/CL 150/CL 300/JIS 10K/JIS 20K DN 80, 100, 150, 3", 4", 6"
Data Sheet 819584-00 Issue Date: 01/17 Ball Float Steam Trap UNA 43 PN 16/C 125/JIS 10K UNA 46 PN 40/C 150/C 300/JIS 10K/JIS 20K DN 80, 100, 150, 3", 4", 6" UNA 43 hl, UNA 46 hl UNA 43 v, UNA 46 v with
More informationGeneral Specifications
General Specifications GS 34P02P31-01E Gas Flow Calculation Portfolio (FCN-100/FCN-RTU/FCJ) GENERAL This general specification document describes the Gas Flow Calculation Portfolio on FCN/FCJ autonomous
More informationThe flow direction must be observed during installation. It can be recognized by the following features: Flow direction. Gasket
6.2 Installation of the Safety Valve The correct installation within a plant is essential for the proper operation of a safety valve. Installation in this sense is e.g. - the choice of the gaskets - the
More information2-Port Seat Valves with Flange, PN 16
4 40 2-Port Seat Valves with Flange, PN 6 VVF4... Grey cast iron EN-GJL-250 valve body DN 50...50 k vs 9...00 m /h Can be equipped with SQX- electromotoric or SKD...-, SKB...- or SKC...- electrohydraulic
More informationGeneral Specifications
General Specifications GS 34P02P31-02E Gas Flow Calculation Portfolio (FCN-RTU) GENERAL This general specification document describes the Gas Flow Calculation Portfolio on FCN-RTU low power autonomous
More informationVPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10
/ ED VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES OPERATING PRINCIPLE The VPPL are variable displacement axial-piston pumps with variable swash plate, suitable for applications
More informationUse equation for the cylindrical section and equation or for the ends.
Solution 13.1 See section 13.3.4, equations 13.7 to 13.18 Solution 13.2 Use equation 13.34. (a) rigid constant C = 0.43 (b) free to rotate, C = 0.56 Solution 13.3 See section 13.5.1 Use equation 13.39
More informationIntegral type Differential pressure flowmeter VNT Series
Integral type Differential pressure flowmeter VNT Series OUTLINE VH series Wafer-Cone differential pressure flowmeter and high precision differential pressure transmitter are integrated into one flowmeter.
More informationCavitation in Valves
VM CAV/WP White Paper Cavitation in Valves Table of Contents Introduction............................... 2 Cavitation Analysis.......................... 2 Cavitation Data............................. 3
More informationPart 6: Critical flow orifices
Provläsningsexemplar / Preview INTERNATIONAL STANDARD ISO 6145-6 Third edition 2017-07 Gas analysis Preparation of calibration gas mixtures using dynamic methods Part 6: Critical flow orifices Analyse
More informationPressure reducing valves Index
Index General information page Introduction 506 General introduction 507 for a steam plant 509 Product information BSP thread page Brass 510 ; BSP female thread 511 ; BSP male thread 513 Stainless steel
More informationAn Investigation of Liquid Injection in Refrigeration Screw Compressors
An Investigation of Liquid Injection in Refrigeration Screw Compressors Nikola Stosic, Ahmed Kovacevic and Ian K. Smith Centre for Positive Displacement Compressor Technology, City University, London EC1V
More informationFILTER BYPASS CONTROL
Differential Control Valve Series 110 The Series 110 Differential Control Valve is designed to accurately control the pressure difference between any two points. In some systems this means the valve remains
More informationHOW TO NOT MEASURE GAS - ORIFICE. Dee Hummel. Targa Resources
HOW TO NOT MEASURE GAS - ORIFICE Dee Hummel Targa Resources Introduction Measuring natural gas is both a science and an art. Guidelines and industry practices explain how to accurately measure natural
More informationHUMOR 20. High Accuracy Humidity Calibrator. Water T, p1 HUMOR 20 V1.0
High Accuracy Humidity Calibrator The role of humidity calibrations that are accurate, reproducible, and documentable is becoming more and more important. ISO quality guidelines and regulations according
More informationUsing the CONVAL software for the petrochemical plant control valves checking. Case study
Using the CONVAL software for the petrochemical plant control valves checking. Case study C. Patrascioiu, G. Stamatescu, C. Lazar Abstract In the paper there are presented the researches into field of
More informationSingle & Headered Relief Vent Piping Analysis
Single & Headered Relief Vent Piping Analysis Todd Jekel, Ph.D., P.E. Industrial Refrigeration Consortium 2005 Research & Technology Forum January 21, 2005 Madison, WI 1 Purpose Vent piping requirements
More informationINTRODUCTION TO REGULATOR AND RELIEF VALVE SIZING. Introduction
INTRODUCTION TO REGULATOR AND RELIEF VALVE SIZING MARK DYKOFF MANAGER, GAS REGULATION AND CONTROL CALTROL, INC. Introduction Regulators used in natural gas applications are devices made up of a valve and
More informationVersaFlow Vortex 100 Vortex Flow Meter Technical Datasheet. Specification. The all-in-one solution. Highlights. Industries.
VersaFlow Vortex 100 Vortex Flow Meter Technical Datasheet 34-VF-03-05 September 3rd, 2008 Specification The all-in-one solution The VERSAFLOW is the only vortex flowmeter with integrated pressure and
More informationLooking Beyond Relief System Design Standards
Looking Beyond Relief System Design Standards M. Reilly & T. Craddock Introduction A correctly designed relief system is key to safe plant design and operation, ensuring the ability to handle any potential
More informationBall Float Steam Trap UNA 45 MAX, UNA 46 MAX, UNA 46A MAX PN 40/Class 300 DN 40, 50, 65
Data Sheet 819346-02 Issue Date: 05/17 Ball Float Steam Trap UNA 45 MAX, UNA 46 MAX, UNA 46A MAX PN 40/Class 300, 50, 65 UNA 45hl MAX, UNA 46hl MAX, UNA 46Ahl MAX UNA 45v MAX with cover for mounting electrode
More informationSeries 42 Self-operated Regulators Differential Pressure Regulators with Type 2424/Type 2428 Actuator (closing) Type Type 42-28
Series 42 Self-operated Regulators Differential Pressure Regulators with Type 2424/Type 2428 Actuator (closing) and balanced Type 2422 Valve Type 42-24 Type 42-28 Application Differential pressure regulators
More informationRupture Disc Sizing for Micro Motion Coriolis Sensors
Rupture Disc Sizing for Micro Motion Coriolis Sensors www.emerson.com/micromotion Rupture Disc Sizing White Paper 1 Introduction Emerson s Micro Motion Coriolis flow meters are widely used in many industries
More informationVertical Bladder Tanks
DATA SHEET Vertical Bladder Tanks Features UL Listed and FM Approved for use with various ANSUL proportioners and foam concentrates 175 psi (12.1 bar) maximum allowable working pressure (design pressure)
More informationPressure and/or Temperature Pilot Operated Steam Regulators Series 2000
Hoffman Specialty Regulators Regulators Pressure and/or Temperature Operated Regulators Series 2000 The Hoffman Specialty Series 2000 consists of main valves, pilot valves, wells and hardware kits. They
More informationGas density monitor With integrated transmitter Model GDM-100-TI
SF 6 gas solutions Gas density monitor With integrated transmitter Model GDM-100-TI grid Products WIKA data sheet SP 60.05 for further approvals see page 5 Applications Gas density monitoring of closed
More informationSTANDARD SPECIFICATION FOR FLOW INSTRUMENTS DOCUMENT NO : 44-LK /J.02/0006-A4
Page 1 of 9 ` STANDARD SPECIFICATION FOR FLOW INSTRUMENTS DOCUMENT NO : 44-LK-5102-00/J.02/0006-A4 Rev No. Issue Date Pages Rev Description Prepared A 12.08.08 9 Issued for Comments / Approval By Checked
More informationSi C132. Safety valves for pressure relief in accordance to PED, DIN/EN and ASME. Engineering GREAT Solutions
Safety valves for pressure relief in accordance to PED, DIN/EN and ASME Engineering GREAT Solutions Si C132 Features The universal compact safety valve > 3 body seat sizes for appropriate size selection
More informationTube rupture in a natural gas heater
Tube rupture in a natural gas heater Dynamic simulation supports the use of a pressure safety valve over a rupture disk in the event of a tube rupture HARRY Z HA and PATRICK STANG Fluor Canada Ltd A fast
More informationVortex flowmeters. Product family introduction Principle of operation Product review Applications Key product features
Vortex flowmeters introduction Product review s Key product features This document should not be duplicated, used, distributed, or disclosed for any purpose unless authorized by Siemens. Page 1 Vortex
More informationCONTROL VALVE TESTING
The optimal functioning of the Control valve not only exists of sufficient body & seat tightness, but more important, the total "performance" of the valve and its controls! For an accurate and reliable
More informationEngineering Letter. Pump Protection
Engineering Letter Pump Protection Content 1. Introduction...1 1.1 What systems are available to ensure the minimum flow through the pump at all times?...2 1.1.1 Continuous Bypass System...2 1.1.2 Controlled
More informationFlowatch Multiphase Flow Meter
Multiphase Flow Meter Multiphase Flow Meter Key Components Pietro Fiorentini's FLOWATCH is a non-intrusive, non radioactive, in-line multiphase meter for measuring flow rates of oil, water and gas from
More informationWater valve Type WVO. Data sheet MAKING MODERN LIVING POSSIBLE
MAKING MODERN LIVING POSSIBLE Data sheet Water valve Type WVO Water valve type WVO is used for regulating the flow of water in refrigeration plant with water-cooled condensers. The water valve gives modulating
More informationSELECTION CRITERIA FOR SAFETY VALVE
mdmdmdpag 1 di 17 SELECTION CRITERIA FOR SAFETY VALVE CALCULATION OF THE DISCHARGE CAPACITY (Ref. EN 13136:2013) The calculation of the minimum discharge capacity is linked to the system configuration
More informationTelefon (+45) Telefax (+45)
Uni-Valve A /S VENTILER & INSTRUMENTER Telefon (+45) 43 43 82 00 Telefax (+45) 43 43 74 75 mail@uni-valve.com www.uni-valve.com UNI-S83 / S84 3/4-way ball valve Installation and Operating manual 3/4-WAY
More informationSelf-operated Regulators Accessories Differential Pressure and Flow Regulators
Self-operated Regulators Accessories Differential Pressure and Flow Regulators Compression-type fittings Needle valves Compensation chambers Orifice plates Welding neck flanges Control lines Application
More informationSafety relief valves SFV 20-25
MAKING MODERN LIVING POSSIBLE Technical brochure Safety relief valves SFV 20-25 www.danfoss.com/ir Contents Page Introduction........................................................................................3
More informationHorizontal Bladder Tanks
DATA SHEET Horizontal Bladder Tanks Features UL Listed and FM Approved for use with various ANSUL proportioners and foam concentrates 175 psi (12.1 bar) maximum allowable working pressure (design pressure)
More informationUNIQUE ADVANTAGES OF PIPENET
UNIQUE ADVANTAGES OF PIPENET TRANSIENT MODULE Sunrise Systems Limited Section 1: Unique Advantages of the leading hydraulic analysis software engineers prefer to use: PIPENET s schematic design is unique.
More informationPneumatic high-pressure controller Model CPC7000
Calibration technology Pneumatic high-pressure controller Model CPC7000 WIKA data sheet CT 27.63 Applications Healthcare and avionics industry Industry (laboratory, workshop and production) Transmitter
More informationSafety relief valves Type SFV 20-25
Data sheet Safety relief valves Type SFV 20-25 SFV 20-25 are standard, back pressure dependent safety relief valves in angle-way execution, specially designed for protection of vessels and other components
More informationInstructions for SMV 3000 Multivariable Configuration (MC) Data Sheets
Instructions for SMV 3000 Multivariable Configuration (MC) Data Sheets Similar to the TC option for ST 3000 transmitters, the MC option for the SMV 3000 provides a service to our customers which results
More informationSFC. SKYLINE FLOW CONTROLS INC. The Leader of Accurate and Reliable Flow Measurement DESCRIPTION & APPLICATIONS: ADVANTAGES:
SKYLINE FLOW CONTROLS INC. SFC Skyline Flow Controls Wedge Meter (SFC-WM) The SFC wedge meter is a differential pressure device for use on all fluids. It is especially designed for slurries and liquids
More informationCHE Well Testing Package/Service:
CHE Well Testing Package/Service: CHE delivers well testing package And services, trailer mounted well testing package and offshore/onshore well testing services with over 10 years experience. Our testing
More informationNorval Pressure regulator
Norval Pressure regulator NORVAL Classification and Field of Application The NORVAL is a downstream pressure regulator, self actuated, spring loaded for medium and low pressure applications. It is suitable
More informationGuideline No.M-05(201510) M-05 AIR COMPRESSOR. Issued date: 20 October China Classification Society
Guideline No.M-05(201510) M-05 AIR COMPRESSOR Issued date: 20 October 2015 China Classification Society Foreword This Guideline constitutes the CCS rules, and establishes the applicable technical requirements
More informationONSITE PROVING OF GAS METERS. Daniel J. Rudroff WFMS Inc West Bellfort Sugar Land, Texas. Introduction
ONSITE PROVING OF GAS METERS Daniel J. Rudroff WFMS Inc. 13901 West Bellfort Sugar Land, Texas Introduction With the increased use of Natural Gas as a fuel, and higher natural gas prices buyers and sellers
More informationRELIEF VALVES IN PARALLEL
RELIEF VALVES IN PARALLEL Mary Kay O'Connor Process Safety Center International Symposium BEYOND REGULATORY COMPLIANCE MAKING SAFETY SECOND NATURE October 26-28, 2010 James R. Lawrence Sr. Why use a Relief
More informationModel MTB-ASME Vertical Bladder Tanks
DATA SHEET Model MTB-ASME Vertical Bladder Tanks Features n UL Listed for use with various proportioners and foam concentrates n 175 psi (12.1 bar) maximum allowable working pressure (design pressure)
More informationMultiphase MixMeter. MixMeter specification. System Specification. Introduction
System Specification Multiphase MixMeter Introduction The MixMeter is unique in applying proper homogenization techniques to multiphase measurement. In so doing the MixMeter avoids the requirement for
More informationAutomatically or individually calculated.
GASCalc 5.0 GASCalc 5.0 is a Windows based suite of calculation tools for the natural gas professional. Routines are provided for calculating numerous parameters associated with the design and operation
More informationVB-7212 Series. Application. Features. Applicable Literature. 5/8" O.D., 45 SAE Flared Stem Up Open, Two-Way Valves General Instructions
VB-7212 Series 5/8" O.D., 45 SAE Flared Stem Up Open, Two-Way Valves General Instructions Application VB-7212 series single seat, stem up open, two-way valves control water from 20 to 281 F (-7 to 138