1 Directional Control Valves echnical Information

2 Using this manual Organization and headings o help you quickly find information in this manual, the material is divided into sections, topics, subtopics, and details, with descriptive headings set in red type. Section titles appear at the top of every page in large red type. opic headings appear in the left hand column in OLD RED CIL LEERS. Subtopic headings appear in the body text in bold red type and detail headings in italic red type. References (example: See opic xyz, page XX) to sections, headings, or other publications are also formatted in red italic type. In ortable Document Format (DF) files, these references represent clickable hyperlinks that jump to the corresponding document pages. ables, illustrations, and complementary information ables, illustrations, and graphics in this manual are identified by titles set in blue italic type above each item. Complementary information such as notes, captions, and drawing annotations are also set in blue type. References (example: See Illustration abc, page YY) to tables, illustrations, and graphics are also formatted in blue italic type. In DF files, these references represent clickable hyperlinks that jump to the corresponding document pages. Special text formatting Defined terms and acronyms are set in bold black type in the text that defines or introduces them. hereafter, the terms and acronyms receive no special formatting. lack italic type is used in the text to emphasize important information, or to set-off words and terms used in an unconventional manner or alternative context. Red and blue italics represent hyperlinked text in the DF version of this document (see above). able of contents n indented able of Contents (OC) appears on the next page. ables and illustrations in the OC set in blue type. In the DF version of this document, the OC entries are hyperlinked to the pages where they appear Sauer-Danfoss. ll rights reserved. rinted in U.S.. Sauer-Danfoss accepts no responsibility for possible errors in catalogs, brochures and other printed material. Sauer-Danfoss reserves the right to alter its products without prior notice. his also applies to products already ordered provided that such alterations aren t in conflict with agreed specifications. ll trademarks in this material are properties of their respective owners. Sauer-Danfoss and the Sauer-Danfoss logotype are trademarks of the Sauer-Danfoss Group. Front cover illustrations: F , F , F , F , F , F , F , F , F , L0564 Revision February 2006

3 Contents roduct overview Flexibility of design... 6 Circuit options... 6 Capability... 6 ctuation options... 6 Modular valves... 7 Monoblock valves... 7 Features and ratings by model... 8 Quick selection matrix Features and ratings by model... 9 Fluids and filtration Fluids...10 ase stock and additives...10 Viscosity...10 Filtration...10 Return line filtration...10 Cleanliness...10 Model 1612 Description...11 ypical applications...11 Standard features...11 ressure drop...12 echnical data...12 Options...12 Relief valve...13 Handles...13 Dimensions...14 Model 1617 Description...15 ypical applications...15 Standard features...15 Other features available...15 ressure drop...16 echnical data...16 Options...16 Dimensions...18 Model 1627 Description...19 ypical applications...19 Standard features...19 Other features available...19 ressure drop...20 echnical data...20 Options...20 Dimensions L0564 Revision February 2006

4 Contents Model 1637 Description...23 ypical applications...23 Standard features...23 Other features available...23 ressure drop...24 echnical data...24 Options...24 Dimensions...26 Model 1618 Description...27 ypical applications...27 Standard features...27 ressure drop...28 echnical data...28 Options...28 Dimensions...30 CDS 60 and 100 Specifications...31 ypical performance...32 Inlet covers order code...33 Inlet porting and relief valve options...34 Mid-inlet flow dividers and combiners order code...35 Mid-inlet flow dividers and combiners...36 Outlet covers order code...37 Outlet porting and plug options...38 Work section order code...39 Circuit types...42 Spool types...43 ctuation options...44 Cabling and electrical options for actuator types G, H, and J...47 ctuation mounting side...47 Spool centering and detent options...48 uxiliary valves...50 Dimensions CDS Dimensions CDS Model 1125 ypical applications...53 Standard features...53 ressure drop curves...54 ressure rise curves(system relief valve SVR)...55 ressure rise curves(work port relief valve SVL)...56 orting...57 Handles SVM...57 echnical data...57 Options...57 ypical circuit...58 Dimensions...59 Exploded view L0564 Revision February 2006

5 Contents ppendix 1 Order forms Spool valve order form...61 CDS60 and CDS100 specification worksheet...63 CDS60 and CDS100 price worksheet Stack Valve Specifications Order Form instructions L0564 Revision February

6 roduct overview Flexibility of design he Sauer-Danfoss directional control valves are designed to give customer flexibility over a broad range of flow and pressure capabilities. ctuator options include a range of levers, cable actuators, hydraulic and pneumatic pilot controls, two-axis joysticks, and electrohydraulic solenoids. Flow rates range from 0 to 100 l/min [26 US gal/min]. Configurations include compact monoblock and flexible modular styles. Circuit options arallel circuits Series circuits andem circuits riority circuits Regenerative circuits ower beyond Open center Closed center Capability Flow rates from 0 to 100 l/.min [26 US gal/min] System pressure up to 240 bar [3500 psi] Up to 12 work sections for modular valves 12 cm³/min [0.7 in³/min] leakage (0.5 cm³/min [0.03 in³/min] for 1618) ctuation options Handles and levers Mechanical two-axis joystick Exposed or covered spool ends Remote Hydraulic Control (RHC) ElectroHydraulic Control (EHC) on/off solenoid Cable control Hydraulic or pneumatic pilot control Dual spool ends Refer to the quick selection matrix on pages 12 and 13 for specific options by model L0564 Revision February 2006

7 roduct overview Modular valves Valve model l/min [US gal/min] Number of Spools CDS [26] 1 to 12 CDS [16] 1 to 12 Circuit age arallel andem Series arallel andem Series [10] 1 to 8 arallel Monoblock valves Valve model l/min [US gal/min] 0 [5] 40 [11] 60 [16] 80 [21] 100 [26] Number of Spools [20] 1 andem [10] 1 arallel [10] 2 arallel [10] 3 arallel [10] 1 arallel Circuit age Indicates Maximum Working ressure Rated t 210 bar [3000 psi] 520L0564 Revision February

8 Quick selection matrix Features and ratings by model Monolock Modular Category Rating / feature 1617/27/ CDS60 CDS100 Nominal flow 19 l/min [5 US gal/min] 38 l/min [10 US gal/min] X X X 57 l/min [15 US gal/min] X X 76 l/min [20 US gal/min] 95 l/min [25 US gal/min] X 114 l/min [30 US gal/min] Nominal pressure 138 bar [2000 psi] 207 bar [3000 psi] X X X X X X Circuit options arallel X X X X X Series X andem X X X riority X ower beyond X X X X X X Closed center X X Spools Distance between (mm [in]) 28.7 [1.13] 28.7 [1.13] Maximum number N/ 35 [1.38] 36 [1.42] 44.5 [1.75] Spring center X X X X X X 1 position detent X X X X 2 position detent X X X X X X Spool action options 3 position detent X X X X X X Friction detent Float detent X X X X X Regenerative feel Spring offset X X X X 3 pos. - 3 way X X X X X X Spool options 3 pos. - 4 way X X X X X X 4 pos. with float X X X X 4 pos. regenerative mm [0.500 in] Spool diameter mm [0.625 in] X X X X mm [0.75 in] X X mm [1.000 in] Relief valve options all and spring X X X X Direct acting poppet X X ilot operated X X X X Work port neutral options Closed to tank X X X X X X Open to tank X X X X X X Meter to tank X X X X 8 520L0564 Revision February 2006

9 Quick selection matrix Features and ratings by model Monolock Modular Category Rating / feature 1617/27/ CDS60 CDS100 ctuation options Handle X X X X X X Mechanical joystick X X X X Exposed spool end X X X X X X Covered spool end X X RHC X X X EHC on/off X X Cable control X X Hydraulic / pneumatic X X Dual spool ends X X Maximum work port leakage <1 cm 3 /min [0.061 in 3 /min] 1 to 3 cm 3 /min [0.061 to in 3 /min] 4 to 6 cm 3 /min [0.244 to in 3 /min] 7 to 10 cm 3 /min [0.427 to in 3 /min] 11 to 13 cm 3 /min [0.71 to in 3 /min] 14 to 16 cm 3 /min [0.854 to in 3 /min] 16 to 24 cm 3 /min [0.976 to in 3 /min] X X X X X X Load check X X X X X X.O. check X X X X dditional features Flow control X X Meter in X X X X Meter out X X Hydraulic kickout X X X Electric switch X X X 520L0564 Revision February 2006

10 Fluids and filtration Fluids Hydraulic fluid performs three basic functions in a hydraulic system: It transfers energy, lubricates moving components, and transports heat and contaminants out of the system. ase stock and additives Sauer-danfoss valves are designed to operate with mineral-based fluids containing oxidation, rust, and foam inhibitors, compatible with fluoroelastomer seals. Consult your fluid supplier for information on seal compatibility. Viscosity Viscosity is the most important property of a hydraulic fluid. It is a measurement of how the fluid resists flow. Low viscosity fluids increase internal leakage; high viscosity fluids increase pressure drop through the valve. Use a fluid that meets the viscosity limits published in this catalog. For specific requirements, see technical data in each section. emperature emperature affects a fluid s viscosity. Higher temperature fluid has lower viscosity. Operating at excessive temperatures may have other detrimental effects on your hydraulic fluid. Design your hydraulic system to operate within the specified temperature range. Specific requirements are published in each section. For more information For more information on hydraulic fluid selection refer to Hydraulic Fluids and Lubricants, Sauer-Danfoss publication 520L0463. Filtration Effective filtration is critical to a hydraulic system s performance and working life. Employ system filtration capable of meeting the published requirements in each valve section. e aware that other components in the system may have more stringent requirements. Design your filtration system to satisfy the requirements of the most sensitive component. Return line filtration Return line filtration is generally adequate for Sauer-Danfoss valves. We recommend a 10 micron nominal (20 micron absolute) or finer filter. Insure the filter in your system is properly sized and maintained. o facilitate proper filter maintenance, use a pressure gauge or other indicator to signal when it is necessary to change the filter. Never allow filter to reach its bypass condition. Follow the filter manufacturer s maintenance recommendations. Cleanliness Hydraulic system contamination must not exceed the limits published for each valve. Limits are specified per ISO 4406 (1999). When measuring system contamination, calibrate test equipment in accordance with the CFD method. For more information For more information on system filtration, refer to Design Guidelines for hydraulic fluid cleanliness, Sauer-Danfoss publication 520L L0564 Revision February 2006

11 Model 1612 Description Single spool monoblock valve. 76 l/min [20 US gal/min] maximum flow. 207 bar [3000 psi] maximum pressure. ypical applications Sweepers, mowers, agricultural equipment, auxiliary valves, tree removal equipment Standard features ll valves supplied with clevis end spools ower-beyond port machined and plugged (use whenever a downstream valve is required) Cast-iron body Chrome plated spools select fit to body for leakage control aint color: black primer Load check for each spool to prevent drop before raise Individually boxed and labeled 520L0564 Revision February

12 Model 1612 ressure drop ressure - bar [psi] 15.3 [225] [200] 12 [175] [150] 8.8 [125] 6.9 [100] 5 [75] 3.45 [50] 1.7 [25] [5] 38 [10] Flow - l/min [US gal/min] 57 [15] 76 [20] -W W- MODEL 32 - MODEL 22 - MODEL 12 - echnical data Maximum pressure 207 bar [3000 psi] Maximum tank line pressure 69 bar [1000 psi] Maximum oil flow 76 l/min [20 US gal/min] Spool travel in and out from neutral 6.3 mm [0.25 in] Spool travel to float position from neutral 12.6 mm [0.50 in] Maximum port leakage at 69 bar [1000 psi] 21 mm²/sec (cst) [102 SUS] 24 cm 3 /min [1.46 in³/min] Maximum lift check leakage at 69 bar [1000 psi] 21 mm²/sec (cst) [102 SUS] 82 cm 3 /min [82 cm 3 /min] Minimum oil temperature -29 C [-20 F] Maximum oil temperature 82 C [180 F] mbient temperature range -29 to 60 C [-20 to 140 F] Minimum viscosity 6 mm²/sec (cst) [45 SUS] Maximum viscosity 440 mm²/sec (cst) [2000 SUS ] Fluid cleanliness per ISO /16 typical spool effort: dry, full stroke 231 N [53 lbf ] Weight 3.18 kg [7 lbs] Options Spool types Code Symbol Description V F way, 3-position Open center Work ports blocked to tank in neutral position 4-way, 3-position Open center port blocked to tank 4-way, 4-position Open center Work ports blocked to tank in neutral position, open to tank in fourth position or float L0564 Revision February 2006

13 Model 1612 Options (continued) Code Symbol Description X O way, 3-position Open center Work port blocked to tank in neutral position 4-way, 3-position Motor open center Work ports open to tank in neutral position Spool action Code Description Code Description Spring centered, detent in float N Spring centered, detent in D 3-position detent S Spring centered L Spring centered, detent out Relief valve ilot operated relief valve 0.4 bar per liter [20 psi per gallon] rise No restrictions on setting up to 207 bar [3000 psi] djustable standard orting Inlet/outlet Locations available Work ports 7/8-14, SE (standard) 3/4-16 SE top and side 3/4-16, SE (standard) Handles C-hook kit Standard handle with C-hook kit ivot-block handle kit 520L0564 Revision February

14 Model 1612 Dimensions INLE OR 7/8-14 S..E. 2 WORK ORS 3/4-16 S..E. 6.4 [0.25] 8.6 [0.34] OULE OR 7/8-14 S..E [2.06] 20.6 [.81] 74.7 [2.94] 22.4 [0.88] 22.4 [0.88] ø.352/ MG. HOLES 5.1 [0.20] 45.7 [1.80] 7.9 [0.31] 66.0 [2.60] 97.8 [3.85] [4.88] 6.50 [0.256] ø 6.43 [0.253] HRU [6.56] [4.83] 51.6 [2.03] 44,2 [1.74] 41.1 [1.62] 50.8 [2.00] 39.6 [1.56] 6.50 [0.256] ø 6.43 [0.253] HRU OWER EYOND OR 7/8-14 S..E. (shown for dimensional reference only) mm [in] L0564 Revision February 2006

15 Model 1617 Description Single spool directional control valve with parallel circuitry. 38 l/min [10 US gal/min] maximum flow. 207 bar [3000 psi] maximum pressure. ypical applications Lawn and garden tractors, mowers, small tractor loader attachments, sweepers, utility trucks, trenchers, agricultural equipment Standard features ll valves supplied with clevis end spools ower-beyond port machined and plugged (use whenever a downstream valve is required) Cast-iron body Chrome plated spools select fit to body for leakage control aint color: black primer Load check for each spool to prevent load drop before raise Float conversion (add float detent kit to standard spool) Open transition valve Individually boxed and labeled Other features available ang end spool for cable control Unidirectional or bidirectional drop-in work port orifice plates 520L0564 Revision February

16 Model 1617 ressure drop [240] ressure - bar [psi] [180] 8.16 [120 ] 4.08 [60] -W W [5] 38 [10] Flow - l/min [US gal/min] 57 [15] echnical data Maximum pressure 207 bar [3000 psi] Maximum tank line pressure 69 bar [1000 psi] Maximum oil flow 38 l/min [10 US gal/min] Spool travel in and out from neutral 4.8 mm [0.19 in] Spool travel to float position from neutral 9.65 mm [0.38 in] Maximum port leakage at 69 bar [1000 psi] 21 mm²/sec (cst) [102 SUS] Maximum lift check leakage at 69 bar [1000 psi] 21 mm²/sec (cst) [102 SUS] 16 cm 3 /min [1 in³/min] 82 cm 3 /min [5 in³/min] Minimum oil temperature -29 C [-20 F ] Maximum oil temperature 82 C [180 F] mbient temperature range -29 to 60 C [-20 to 140 F] Minimum viscosity 6 mm²/sec (cst) [45 SUS] Maximum viscosity 440 mm²/sec (cst) [2000 SUS] Fluid cleanliness per ISO /16 ypical spool effort: dry, full stroke 231 N [52 lbf ] Weight 2.26 kg [5 lbs] Options Spool types Code Symbol Description C F O, C or E, C or E, D or F , C or E, D or F, D or F way, 3-position Closed center Work ports blocked to tank in neutral position 4-way, 4-position Open center Work ports blocked to tank in neutral position Open to tank in fourth position or float 4-way, 3-position Motor open center Work ports open to tank in neutral position L0564 Revision February 2006

17 Model 1617 Options (continued) Code Symbol Description V X, C or E, C or E, D or F , D or F way, 3-position Open center Work ports blocked to tank in neutral position 3-way, 3-position Open center Work ports blocked to tank in neutral position (, D, or F) 3-way, 3-position Open center Work ports blocked to tank in neutral position (, C, or E) Spool action Code Description Code Description Spring centered, detent in float N Spring centered, detent in D 3-position detent S Spring centered L Spring centered, detent out Relief valve Code Description 2 Direct-acting ball and spring 1 bar/l [50 psi/gal] rise Standard setting 83 bar [1200 psi] crack pressure at 2.9 l/min [0.75 US gal/min] Not for use on setting over 30 l/min [8 US gal/min] Full flow setting at 138 bar [2000 psi] 3 ilot operated relief valve 0.4 bar/l [20 psi/gal] rise No restrictions on setting up to 210 bar [3000 psi] Standard setting 138 bar [2000 psi] crack pressure at 2.9 l/min [0.75 US gal/min] orting Inlet/outlet 3/4-16, SE 8 Locations available Work ports inlet-side, top, end outlet-top, end 9/16-18, SE-6 ower-beyond port machined and plugged. (Remove plug and install sleeve for power-beyond feature.) Handles Code C H N Description C-hook kit Standard handle with C-hook kit ivot-block handle kit No handles 520L0564 Revision February

18 Model 1617 Dimensions DIREC CING OR ILO OERED RELIEF VLVE OIONS VILLE 9.7 [0.38] [4.62] 90.4 [3.56] 85.9 [3.38] 72.4 [2.85] 49.3 [1.94] 19.8 [0.78] SIDE INLE OR 3/4-16 S..E. O INLE OR 3/4-16 S..E. ø 6.76 [0.266] MG HOLES 2 LCES END INLE OR 3/4-16 S..E. OU NEURLl 4.8 [0.19] 8.6 [0.34] 22.4 [0.88] IN 4.8 [0.19] FLO 9.7 [0.38] [5.12] [4.20] 33.3 [1.31] 19.6 [0.77] 14.7 [0.58] IN OU 9.7 [0.38] 57.2 [2.25] 31.8 [1.25] 65.0 [2.56] O OULE OR 3/4-16 S..E. OIONL OWER EYOND OR 3/4-16 S..E. Shown for dimensional reference only 76.2 [3.00] 57.2 [2.25] 6.4 [0.25] END OULE OR 3/4-16 S..E [0.75] 35.1 [1.38] 50.8 [2.00] 60.2 [2.37] [6.14] [6.64] IVO LOCK HNDLE OION ("" CODE) 23.9 [0.94] 19.1 [0.75] [3.95] 65.0 [2.56] 31.8 [1.25] 39.6 [1.56] 0.5 [0.02] [6.19] ø6.50 HRU,Y [0.256] [0.253] SNDRD HNDLE OION "H" CODE CLEVIS HNDLE 6.53 ø 5.40 [0.257] [0.252].03 X 45 CMFR 3.18 R [0.125] [0.88] 6.50 ø 6.43 DI.,HRU [0.256] [0.253] [7.56] [7.64] 15.0 [0.59 D] 8.74 [0.344] mm [in] L0564 Revision February 2006

19 Model 1627 Description wo-spool directional control valve with parallel circuitry. 38 l/min [10 US gal/min] maximum flow. 207 bar [3000 psi] maximum pressure. ypical applications Lawn and garden tractors, mowers, small tractor loader attachments, sweepers, utility trucks, trenchers, agricultural equipment Standard features ll valves supplied with clevis end spools ower-beyond port machined and plugged (use whenever a downstream valve is required). Cast-iron body Chrome plated spools select fit to body for leakage control aint color: black primer Load-check for each spool to prevent load drop before raise Float conversion (add float detent kit to standard spool) Open transition valve Individually boxed and labeled Other features available ang-end spool (for cable control) Single handle, mechanical joystick control (model 1627) Unidirectional or bidirectional drop-in work port orifice plates Range of port sizes 520L0564 Revision February

20 Model 1627 ressure drop [240] ressure - bar [psi] [180] 8.16 [120] -W - W [60] [5] 38 [10] 57 [15] Flow - l/min [US gal/min] echnical data Maximum pressure 207 bar [3000 psi] Maximum tank line pressure 69 bar [1000 psi] Maximum oil flow 38 l/min [10 US gal/min] Spool travel in and out from neutral 4.8 mm [0.19 in] Spool travel to float position from neutral 9.65 mm [0.38 in] Maximum port leakage at 69 bar [1000 psi] 21 mm²/sec (cst) [102 SUS] Maximum lift check leakage at 69 bar [1000 psi] 21 mm²/sec (cst) [102 SUS] 16 cm 3 /min [1 in³/min] 82 cm 3 /min [5 in³/min] Minimum oil temperature -29 C [-20 F ] Maximum oil temperature 82 C [180 F] mbient temperature range -29 to 60 C [-20 to 140 F] Minimum viscosity 6 mm²/sec (cst) [45 SUS] Maximum viscosity 440 mm²/sec (cst) [2000 SUS] Fluid cleanliness per ISO /16 ypical spool effort: dry, full stroke 231 N [52 lbf ] Weight 3.62 kg [8 lbs] Options Spool types Code Symbol Description C F O, C or E, C or E, D or F , C or E, D or F, D or F way, 3-position Closed center Work ports blocked to tank in neutral position 4-way, 4-position Open center Work ports blocked to tank in neutral position Open to tank in fourth position or float 4-way, 3-position Motor open center Work ports open to tank in neutral position L0564 Revision February 2006

21 Model 1627 Options (continued) Code Symbol Description V X, C or E, C or E, D or F , D or F way, 3-position Open center Work ports blocked to tank in neutral position 3-way, 3-position Open center Work ports blocked to tank in neutral position (, D, or F) 3-way, 3-position Open center Work ports blocked to tank in neutral position (, C, or E) Spool action Code Description Code Description Spring centered, detent in float N Spring centered, detent in D 3-position detent S Spring centered L Spring centered, detent out Relief valve Code Description 2 Direct-acting ball and spring 1 bar/l [50 psi/gal] rise Standard setting 83 bar [1200 psi] crack pressure at 2.9 l/min [0.75 US gal/min] Not for use on setting over 30 l/min [8 US gal/min] Full flow setting at 138 bar [2000 psi] 3 ilot operated relief valve 0.4 bar/l [20 psi/gal] rise No restrictions on setting up to 210 bar [3000 psi] Standard setting 138 bar [2000 psi] crack pressure at 2.9 l/min [0.75 US gal/min] orting Inlet/outlet 3/4-16, SE 8 Locations available Work ports inlet-side, top, end outlet-top, end 9/16-18, SE-6 ower-beyond port machined and plugged. (Remove plug and install sleeve for power-beyond feature.) Handles Code C F H N Description C-hook kit Joystick (option) Standard handle with C-hook kit ivot-block handle kit No handles 520L0564 Revision February

22 Model 1627 Dimensions DIREC CING OR ILO OERING RELIEF VLVE OIONS VILLE OIONL DIREC CING RELIEF 8.6 [0.34] 22.4 [0.88] OU 4.8 [0.19] 4.8 [0.19] NEURL 9.6 FLO [0.38] [5.12] [4.19] 9.7 [0.38] 34.3 [1.35] C 33.3 IN [1.31] [3.56] 85.9 [3.38] 72.4 [2.85] 49.2 [1.94] 19.8 [0.78] 90.4 D 15.0 [0.59] [4.62] 19.6 [0.77] IN OU SIDE INLE OR 3/4-16 S..E. O INLE OR 3/4-16 S..E. ø 6.76 [0.266] MG. HOLES 2 LCES 4 WORK ORS 9/16-18 S..E [4.13] [3.38] [3.69] [3.38] 31.8 [2.38] [1.25] 9.6 [0.38] O OULE OR 3/4-16 S..E. END OULE OR 3/4-16 S..E. OIONL OWER EYOND OR 3/4-16 S..E. Shown for dimensional reference only END INLE OR 3/4-16 S..E. 6.4 [0.25] 35.1 [1.38] 50.8 [2.00] 60.2 [2.37] 19.1 [0.75] [6.66] [6.15] 28.4 [1.12] 39.9 [1.57] 0.5 [0.02] [6.19] ø 6.50 HRU,Y [0.256] [0.563] SNDRD HNDLE OIONL ("H" CODE) 23.4 [0.92] 19.1 [0.75] 6.4 [0.25] 34.3 [1.35] 11.2 [0.44] 43.9 [1.73] 36.1 [1.42] 5.08 ø 5.31 HRU [0.200] [0.209] NG YE SOOL OION mm [in] L0564 Revision February 2006

23 Model 1637 Description hree spool directional control valve with parallel circuitry. 38 l/min [10 US gal/min] maximum flow. 207 bar [3000 psi] maximum pressure. ypical applications Lawn and garden tractors, mowers, small tractor loader attachments, sweepers, utility trucks, trenchers, agricultural equipment Standard features ll valves supplied with clevis end spools ower-beyond port machined and plugged (use whenever a downstream valve is required). Cast-iron body Chrome plated spools select fit to body for leakage control aint color: black primer Load-check for each spool to prevent load drop before raise Float conversion (add float detent kit to standard spool) Open transition valve Individually boxed and labeled Other features available ang-end spool (for cable control) Unidirectional or bidirectional drop-in work port orifice plates 520L0564 Revision February

24 Model 1637 ressure drop 6.9 [100] ressure drop - bar [psi] 3.5 [50] W- -W [5] Flow rate - l/min [US gal/min] 28 [10] echnical data Maximum pressure 207 bar [3000 psi] Maximum tank line pressure 69 bar [1000 psi] Maximum oil flow 38 l/min [10 US gal/min] Spool travel in and out from neutral 4.8 mm [0.19 in] Spool travel to float position from neutral 9.65 mm [0.38 in] Maximum port leakage at 69 bar [1000 psi] 21 mm²/sec (cst) [102 SUS] Maximum lift check leakage at 69 bar [1000 psi] 21 mm²/sec (cst) [102 SUS] 16 cm 3 /min [1 in³/min] 82 cm 3 /min [5 in³/min] Minimum oil temperature -29 C [-20 F ] Maximum oil temperature 82 C [180 F] mbient temperature range -29 to 60 C [-20 to 140 F] Minimum viscosity 6 mm²/sec (cst) [45 SUS] Maximum viscosity 440 mm²/sec (cst) [2000 SUS] Fluid cleanliness per ISO /16 ypical spool effort: dry, full stroke 231 N [52 lbf ] Weight 5.44 kg [12 lbs] Options Spool types Code Symbol Description C O, C or E, C or E, C or E, D or F , D or F , D or F way, 3-position Closed center Work ports blocked to tank in neutral position 4-way, 3-position Motor open center Work ports open to tank in neutral position 4-way, 3-position Open center Work ports blocked to tank in neutral position L0564 Revision February 2006

25 Model 1637 Options (continued) Code Symbol Description V X, C or E, D or F way, 3-position Open center Work ports blocked to tank in neutral position (, D, or F) 3-way, 3-position Open center Work ports blocked to tank in neutral position (, C, or E) Spool action Code Description Code Description Spring centered, detent in float N Spring centered, detent in D 3-position detent S Spring centered L Spring centered, detent out Relief valve Code Description 2 Direct-acting ball and spring 1 bar/l [50 psi/gal] rise Standard setting 83 bar [1200 psi] crack pressure at 2.9 l/min [0.75 US gal/min] Not for use on setting over 30 l/min [8 US gal/min] Full flow setting at 138 bar [2000 psi] 3 ilot operated relief valve 0.4 bar/l [20 psi/gal] rise No restrictions on setting up to 210 bar [3000 psi] Standard setting 138 bar [2000 psi] crack pressure at 2.9 l/min [0.75 US gal/min] orting Inlet/outlet 3/4-16, SE 8 Locations available Work ports inlet-side, top, end outlet-top, end 9/16-18, SE-6 ower-beyond port machined and plugged. (Remove plug and install sleeve for power-beyond feature.) Handles Code C H N Description C-hook kit Standard handle with C-hook kit ivot-block handle kit No handles 520L0564 Revision February

26 Model 1637 Dimensions DIREC CING OR ILO OERED RELIEF VLVE OIONS VILLE [6.14] [5.42] OIONL ILO OERED RELIEF IVO LOCK HNDLE OION ("") CODE 8.6 [0.34] 22.4 [0.88] 4.8 OU [0.19] IN 4.8 [0.19] NEURL FLO 9.7 [0.38] [5.12] [4.20] 23.4 [0.92] 19.1 [0.75] 34.5 [1.36] 9.9 [0.39] [3.95] 65.5 [2.58] 31.8 [1.25] 20.1 [0.79] C E 85.9 [3.38] 49.3 [1.94] 33.3 [1.31] 39.6 [1.56] 0.5 [0.02] [7.56] 72.1 [2.84] D F IN OU SIDE INLE OR 3/4-16 S..E. O INLE OR 3/4-16 S..E. ø 6.76 [0.266] MG HOLE 2 LCES O OULE OR 3/4-16 S..E. OIONL OWER EYOND OR 3/4-16 S..E. Shown for dimensional reference only [6.19] ø 6.50 HRU,Y [0.256] [0.253] [7.65] 19.6 [0.77] 14.7 [0.58] [4.62] [0.38] [1.25] 60.5 [2.38] 88.9 [3.50] SNDRD HNDLE OION ("H" CODE) [4.50] [4.81] CLEVIS HNDLE [5.25] 6 WORK ORS 9/16-18 S..E [4.50] ø [0.257] [0.252].03 x 45 CMFR. 6.4 [0.25] END OULE OR 3/4-16 S..E [0.59 D] 3.18 R [0.125] END INLE OR 3/4-16 S..E [0.88] 19.1 [0.75] 35.1 [1.38] 50.8 [2.00] 60.2 [2.37] 6.50 ø 6.43 DI.,HRU [0.256] [0.253] 8.74 [0.344] L0564 Revision February 2006 mm [in]

27 Model 1618 Description Single spool monoblock valve. 38 l/min [10 US gal/min] maximum flow. 207 bar [3000 psi] maximum pressure. ypical applications Mowers, sweepers, fork lifts, aerial lift equipment, utility trucks, snow blades, trenchers, agricultural equipment Standard features ll valves supplied with clevis end spools ower-beyond port machined and plugged (use whenever a downstream valve is required) Cast-iron body Chrome plated spools select fit to body for leakage control ilot operated checks for low leakage aint color: black primer Closed transition spool timing prevents load drop before raise Individually boxed and labeled 520L0564 Revision February

28 Model 1618 ressure drop 13.6 [200] 12.2 [180] 10.9 [160] 9.5 [140] ressure - bar [psi] 8.2 [120] 6.8 [100] 5.4 [80] 4.1 [60] [40] 1.4 [20] [1] 7.6 [2] 11.4 [3] 15.1 [4] 18.9 [5] 22.7 [6] 26.5 [7] 30.3 [8] 34.1 [9] 37.8 [10] 41.6 [11] 45.4 [12] 49.2 [13] 53.0 [14] 56.8 [15] Flow - l/min [US gal/min] echnical data Maximum pressure 207 bar [3000 psi] Maximum tank line pressure 69 bar [1000 psi] Maximum oil flow 38 l/min [10 US gal/min] Spool travel in and out from neutral 4.8 mm [0.19 in] Maximum standby 69 bar [1000 psi] 21 mm²/sec (cst) [102 SUS] Standard pilot check leakage@ 69 bar [1000 psi] 21 mm²/sec (cst) [102 SUS] 300 cm 3 /min [18 in³/min] 0.5 cm 3 /min [0.03 in³/min] Minimum oil temperature -29 C [-20 F ] Maximum oil temperature 82 C [180 F] mbient temperature range -29 to 60 C [-20 to 140 F] Minimum viscosity 6 mm²/sec (cst) [45 SUS] Maximum viscosity 440 mm²/sec (cst) [2000 SUS] Fluid cleanliness per ISO /16 ypical spool effort: dry, full stroke 231 N [52 lbf ] Weight 2.72 kg [6 lbs] Options Spool types Code Symbol Description O, C or E, D or F way, 3-position Motor open center Work ports open to tank in neutral position L0564 Revision February 2006

29 Model 1618 Options (continued) Spool action Code Description Code Description Spring centered, detent in float N Spring centered, detent in D 3-position detent S Spring centered L Spring centered, detent out Relief valve Code Description 3 ilot operated relief valve 0.4 bar/l [20 psi/gal] rise No restrictions on setting up to 210 bar [3000 psi] Standard setting 138 bar [2000 psi] crack pressure at 2.9 l/min [0.75 US gal/min] orting Inlet/outlet Locations available Work ports 9/16-18 SE, 3/4-6 SE side, end /D ports - end /C ports - top,end 9/16-18 SE ower-beyond port machined and plugged. (Remove plug and install sleeve for power-beyond feature.) Handles Code N Description No handles 520L0564 Revision February

30 Model 1618 Dimensions 5.6 [0.22] 85.9 [3.38] [4.62] IN 6.35 [0.25] WORK OR 9/16-18 S..E. DF OU 77.7 [3.06] 65.0 [2.56] [17/16] DI MG. HOLE 2 LCES 22.1 [0.87] 9.7 [0.38] [1.25] 6.35 [1.56] [5.02] [5.00] 79.3 [3.12] 6.5 [0.256] ø 6.4 [0.253] 35.1 [1.38] OWER EYOND 9/16-18 S..E. Shown for dimensional reference only mm [in] L0564 Revision February 2006

31 CDS 60 and 100 CDS 100 CDS 60 Specifications Maximum flow (CDS 100) 100 l/min [26.4 US gal/min] Maximum flow (CDS 60) 60 l/min [15.8 US gal/min] Work pressure 210 bar [3050 psi] Maximum pressure 250 bar [3625 psi] Maximum pressure (outlet section) 40 bar [580 psi] emperature range -40º to 80º C [-40 to 176º F] Recommended fluid type Mineral based hydraulic oil Recommended viscosity mm²/sec (cst) [ SUS] Minimum fluid cleanliness (per ISO 4406) 19/16 520L0564 Revision February

32 CDS 60 and 100 ypical performance ased on oil temperature of C [ F]. Viscosity 32 mm²/sec (cst) [151 SUS]. CDS spool leakage (standard) at 70 bar [1015 psi], 50 C [122 F], ISO VG46: 10 cm³/min [0.61 in³/min] ressure vs. flow curves for main relief valve ressure - bar [psi] 250 [3625] 200 [2900] 150 [2176] 100 [1450] 50 [725] [2.6] [5.3] [7.9] [10] [13] [16] [19] [21] [24] [26] Flow - l/min [US gal/min] ressure drop (-) CDS 60 ressure drop (-) CDS sections ressure - bar [psi] 16 [232] 14 [203] 12 [174] 10 [145] 8 [116] 12 sections 11 sections 10 sections 9 sections 8 sections 7 sections 6 sections 5 sections 4 sections ressure - bar [psi] 16 [232] 14 [203] 12 [174] 10 [145] 8 [116] 11 sections 10 sections 9 sections 8 sections 7 sections 6 sections 5 sections 4 sections 6 [87] 3 sections 6 [87] 3 sections 4 [58] 2 sections 1 sections 4 [58] 2 sections 2 [29] 2 [29] 1 sections [2.6] [5.3] [7.9] [10] [13] [16] Flow - l/min [US gal/min] [2.6] [5.3] [7.9] [10] [13] [16] [19] [21] [24] [26] Flow - l/min [US gal/min] L0564 Revision February 2006

33 CDS 60 and 100 Inlet covers order code Models Code Description Inlet covers order code (example) E60 C 2 140/40* E100 CDS CDS100 with priority flow control (contact Sauer-Danfoss) E60 CDS60 60 CDS60 with priority flow control (contact Sauer-Danfoss) ort types ort locations Code Description C D op port Side port, top port plugged op port, with side gauge port (1/4-in N) op inlet and outlet ports (use H, I, J on outlet) Main relief valves Code Description C D No valve, with plastic plug No valve, with special plug Valve, with direct valve and external adjustment Valve, with direct valve and internal adjustment Code X hreads Model CDS100 Model CDS60 Inlet outlet #8 3/4-16UNF SE - OR S - arallel Metric - ISO 6149 #10 7/8-14UNF #12 1 1/16-12UNF 3/8-19 1/2-14 3/4-14 M18x1.5 M22x1.5 M27x2 Section Inlet outlet Section Special porting, specify available Note: t this time, North merica only stocks SE-Oring boss. 520L0564 Revision February 2006 * Default relief setting if not specified 33

34 CDS 60 and 100 Inlet porting and relief valve options Inlet covers order code (example) E60 C 2 140/40* ort location D op inlet and outlet (use with H,I,J, and L outlet covers) op inlet E100 inlet cover C op inlet, gauge port side (1/4 in N) Side inlet (top plugged) Relief valve h1 in 11 [0.43] C h 1 in h 7/8 h 7/16 D 67 [2.64] max h1 in E60 inlet cover 47 [1.85] E Ref or (consult factory for dimensional drawing) L0564 Revision February 2006 mm [in] * Default relief setting if not specified

35 CDS 60 and 100 Mid-inlet flow dividers and combiners order code Models Code Description Mid-Inlet flow dividers/combiners order code (example) I /40* I60 CDS 60 mid-inlet I100 CDS100 mid-inlet Mid-inlet type Code Description 1 Flow divider 2 Flow combiner Note: t this time, North merica only stocks SE- Oring boss. ort types Code hreads Model CDS100 Model CDS60 #8 3/4-16UNF SE - OR #10 7/8-14UNF #12 1 1/16-12UNF Mid-inlet Mid-inlet available Main relief valves Code Description 1 lug 2 CDS 60 relief 3 CDS 100 relief 520L0564 Revision February 2006 * Default relief setting if not specified 35

36 CDS 60 and 100 Mid-inlet flow dividers and combiners Min-inlet flow combiner Inlet (Second pump) Relief valve ypass ressure Outlet E Outlet ypass outlet Inlet bypass ressure Min-inlet flow divider Outlet (First pump) Inlet (Second pump) Relief valve Relief valve lug ypass ressure Outlet E Outlet ypass outlet Inlet bypass ressure L0564 Revision February 2006 * Default relief setting if not specified

37 CDS 60 and 100 Outlet covers order code Models Code Description S100 CDS 100 S60 CDS 60 Outlet covers order code (example) S60 2 orts Code C D E F G H I J L Description op outlet Side outlet, top plugged Side outlet for power beyond (top to tank) op outlet (with closed bypass) op outlet (for electrical control) op outlet (for electrical control, with power beyond) Side outlet (for electrical control, top plugged) op plugged op plugged, use with power beyond op plugged for electrical control op plugged for electrical control, use with power beyond ort types Code X hreads Model CDS100 Model CDS60 Inlet outlet #8 3/4-16UNF SE - OR S - arallel Metric - ISO 6149 #10 7/8-14UNF #12 1 1/16-12UNF 3/8-19 1/2-14 3/4-14 M18x1.5 M22x1.5 M27x2 Section Inlet outlet Section Special porting, specify available Note: t this time, North merica only stocks SE-Oring boss. 520L0564 Revision February

38 CDS 60 and 100 Outlet porting and plug options Outlet covers order code (example) S60 2 C S100 outlet cover ypass ressure Outlet H op plugged op outlet (side plugged) I ypass ressure Outlet 30 [1.18] D* ypass ressure Outlet 25 [0.98] Side outlet (top plugged) E ypass ressure Outlet J ypass ressure Outlet 30 [1.18] F ypass ressure Outlet S60 outlet cover L G ypass ressure Outlet CDS [1.20] CDS [1.25] ypass ressure Outlet mm [in] E *ypically used for high pressure standby. CDS [1.20] CDS [1.25] L0564 Revision February 2006

39 CDS 60 and 100 Work section order code Model 100 CDS 100 body for supporting valves CDS 100 normal body (no valves) CDS 60 body for supporting valves CDS 60 normal body (no valves) Circuit types, page 42 1 arallel (no priority) 2 andem (priority) 3 Series (no priority) Spool types, page 43 (also see Spool compatibility, next page) 4-way, closed center C D E F J H 4-way, open center 4-way, closed center, port plugged 4-way, closed center, port plugged 3-way, closed center, port plugged 3-way, closed center, port plugged 4-way, open center, port plugged 4-way, open center, port plugged I Float-spool in (use centering option J ) J Float-spool out (use centering option J) L M N Q R S 4-way, closed center (metering spool) 4-way, open center (metering spool) 4-way, closed center, port plugged (metering spool) 4-way, closed center, port plugged (metering spool) 3-way, closed center, port plugged (metering spool) 3-way, closed center, port plugged (metering spool) 4-way, open center, port plugged (metering spool) 4-way, open center, port plugged (metering spool) Spool actuation, pages No extension (spool actuation side and centering options omitted) C D E Female spool end Male spool end With support (no lever) With lever F neumatic (use centering option ) G H I J L M N Q Cable with lever Cable with joystick (use for the adjacent body) With mechanical joystick (use for the adjacent body) Electrical Hydraulic With mechanical joystick (use for the adjacent body) Enclosed lever E (CDS 60 only) Enclosed mechanical joystick I (CDS 60 only) Enclosed mechanical joystick M (CDS 60 only) Spool actuation mounting side, page 47 1 ctuator mounted on port side (or solenoid side ) 2 ctuator mounted on port side (or solenoid side ) 3 Electrical and (use L centering type) 100 Work section order code (example) 1 E /40* See cabling and electrical options, page L0564 Revision February 2006 * Default relief setting if not specified 39

40 CDS 60 and 100 Work section order code (continued) Spool centering and detents, page Spring centered C D E F G H I J L M N O Q R 3 position detent Spring centered, detent in Spring centered, detent in Spring centered, detent in and Spring centered, hydraulic kickout Spring centered, adjustable stroke Spring centered, female extension Spring centered, male extension Spring centered, detent in float: use for floatation spool Spring centered, use for electrical command y spring offset 2-position detent, spool in 2-position detent, spool out With switch, activates spool in With switch, activates spool in and out With switch, activates two motors 100 Work section order code (example) 1 E /40* ort types Code X hreads Model CDS100 Model CDS60 Inlet outlet #8 3/4-16UNF SE - OR S - arallel Metric - ISO 6149 #10 7/8-14UNF #12 1 1/16-12UNF 3/8-19 1/2-14 3/4-14 M18x1.5 M22x1.5 M27x2 Section Inlet outlet Section Note: at this time, North merica only stocks SE O-ring boss. Special porting, specify available uxiliary valves, page lug C D E F G H I J K L M Direct relief with external adjustment (except electrical actuation) Direct relief with internal adjustment ilot retaining Flow control valve (electrical actuators mounted upside down) nti-cavitation Direct relief with anti-cavitation and external adjustment (except electrical actuation) lastic plug Direct relief with anti-cavitation and internal adjustment (electrical only) lug, for 3-way spools lug, for valves D and E lastic plug, for flow control valve lastic plug, for O checks For valves, C, G, and I, specify pressure and flow Example: (140/40) ressure 140 bar flow 40 l/min L0564 Revision February 2006 Work port side Work port side * Default relief setting if not specified

41 CDS 60 and 100 Work section order code (continued) Spool compatibility Model 60/100 with pilot retaining 60/100 with pilot retaining and hydraulic unlock 60/100 with pilot retaining and electrical spool control 60/100 with flow control 60/100 with flow control and hydraulic unlock Spool types, C, D, G, H E F I J 60/100 with out pilot retaining 60/100 with out pilot retaining with hydraulic unlock 60/100 with out pilot retaining and electrical spool control 60/100 60/100 with hydraulic unlock 60/100 with electrical spool control arallel and tandem Series 520L0564 Revision February

42 CDS 60 and 100 Circuit types 100 Work section order code (example) 1 E /40* 1 arallel circuit (no priority) ypass ressure Inlet Work sections Outlet When two or more sections operate simultaneously, flow favors the lowest pressure. 2 andem circuit (priority) ressure ypass Inlet Work sections Outlet When two or more sections operate simultaneously, only the section closest to the inlet receives flow. 3 Series circuit (no priority) ypass Inlet and Outlet Work Sections Outlet When two or more sections operate simultaneously, the section closest to the inlet receives flow. Return flow feeds the sections downstream L0564 Revision February 2006 * Default relief setting if not specified

43 CDS 60 and 100 Spool types Standard central body ypass core 100 Ref. Description Symbol 4-way closed center Work section order code (example) 1 E /40* L 4-way closed center metering spool 4-way open center ank (x2) ressure core M 4-way open center metering spool ump load check standard on all bodies C N D 4-way closed center port plugged 4-way closed center port plugged metering spool 4-way closed center port plugged E 4-way closed center port plugged metering spool 3-way closed center port plugged Central body for use with auxiliary valves Q F 3-way closed center port plugged metering spool 3-way closed center port plugged R G 3-way closed center port plugged metering spool 4-way open center port plugged S H 4-way open center port plugged metering spool 4-way open center port plugged ump load check standard on all bodies I 4-way open center port plugged metering spool Float spool in (inner inverter) J Float spool out (outer inverter) 520L0564 Revision February 2006 * Default relief setting if not specified 43

44 CDS 60 and 100 ctuation options 100 Work section order code (example) 1 E /40* Without spool end 8 [0.31] CDS CDS 60 [0.26] Female spool end (clevis) 30 CDS 60 [1.18] 34 [1.34] CDS CDS 60 [0.25] 8.4 CDS 100 [0.33] M8 x 1.25 M10 x 1.5 F ø 8 [0.31] C Male spool end (tang) 30 [1.18] CDS [1.34] CDS 100 D With support 66 CDS 60 [2.60] 70 CDS 100 [2.76] M10 x [0.33] M ø 8 [0.31] F neumatic 50 [1.97] 1/8" N (2x) E With lever 113 [4.45] 15º 15º 213 [8.39] Minimum air pressure CDS 60: 5 bar [73 psi] Minimum air pressure CDS 100: 8 bar [116 psi] Maximum air pressure: 12 bar [174 psi] L Hydraulic 56 CDS 60 [2.20] 60 CDS 100 [2.36] 7/16 in UNF SE # 4 (2x) mm [in] * Default relief setting if not specified Minimum pressure CDS 60: 8 bar [116 psi] Minimum pressure CDS 100: 12 bar [174 psi] Maximum pressure: 100 bar [1450 psi] L0564 Revision February 2006

45 15º Directional Control Valves CDS 60 and 100 ctuation options (continued) 100 Work section order code (example) 1 E /40* G Cable with lever** H Cable with joystick** N,, Q Consult factory for drawings E * D * C * * * 26 [1.02] ø 6 [0.24] 280 [11.02] 7 [0.28] 7 [0.28] 50 [1.97] 157 [6.18] 30º 30º [15.55] 40 [1.57] 50 [1.97] 97 [3.82] [4.66] 48 [1.89] Switches have 3 mp capacity 70 Ø [2.76] I/M Mechanical joystick 1 2 I [12.09] 2 15º 1 2 M 2 1 J Electrical** Flying leads 90 [3.54] (Ref.) 1.5m [5 ft] 12VCC 24VCC 83 [3.27] (Ref.) 117 [4.61] (Ref.) 12VCC 24VCC DIN [3.78] (Ref.) **See cabling and electrical options, page 47. Standard sections cannot be converted to electrical due to internal pilot. 520L0564 Revision February 2006 Manual override a Minimum pilot pressure to actuate: 35 bar [500 psi] mm [in] * Default relief setting if not specified 45

46 CDS 60 and 100 Work section order code (example) ctuation options (continued) E /40* N Enclosed lever /Q Enclosed mechanical joystick 100 [3.94] For dimensions, see I/M Mechanical joystick option, previous page L0564 Revision February 2006 * Default relief setting if not specified

47 CDS 60 and 100 Cabling and electrical options for actuator types G, H, and J 100 Work section order code (example) 1 E /40* G: Flexible cable and lock options for spool control lever C Lever lock options Without lock Lock in and/or Lock in central position Standard cables cm (other: consult) Example: how to order 60-1G /40 (lever without lock, 100 cm cable) H: Flexible cable and handle options controls for joystick C D E Joystick handle options Without switches On-Off switch On-Off-On switch Standard cables Example: how to order wo On-Off-On switches cm (other: consult) 60-1H /40 (handle without switches, 100 cm cable) wo On-Off-On switches and one On-Off switch J: Electrical spool voltage and termination options Voltage 12 VDC -lead wires 24 VDC - lead wires E 12 VDC - DIN conn. F 24 VDC - DIN conn. Example: how to order 60-1J3L1 - C - 140/40 (12 VDC coil with lead wires) Force requirements kgf [lbf ] CDS 60 CDS 100 ush/pull min. 2 [4.4] 3.5 [7.7] Max. tension 250 [551] 250 [551] Electrical specifications Voltage mperage () Resistance (Ω) 12 VDC VDC ower: 21 W ctuation mounting side 1 ctuation on port side (RH inlet shown) 2 ctuation on port side (LH inlet shown) CDS100 CDS CDS100 CDS60 520L0564 Revision February 2006 * Default relief setting if not specified 47

48 CDS 60 and 100 Work section order code (example) Spool centering and detent options E /40* Spring centered 3 position detent C Spring center in, detent out 32 [1.25] CDS [1.57] CDS [1.25] CDS [1.57] CDS CDS 60 [2.20] 73 [2.87] CDS 100 Spring force CDS 60: N [32-35 lbf ] CDS 100: N [54-55 lbf ] D Spring center out, detent in E Spring centered, detent in and F Spring centered, hydraulic unlock 56 CDS 60 [2.20] 73 [2.87] CDS CDS 60 [2.20] 73 [2.87] CDS [3.62] CDS [3.78] CDS 100 Note: Unlock body section required for use with hydraulic unlock kit. G Spring centered, adjustable stroke H Spring centered, female extension I Spring centered, male extension 70 CDS 60 [2.76] 81 CDS 100 [3.19] 88±5 [3.46±0.2] CDS ±5 [3.66± 0.2] CDS ±5 [3.46±0.2] CDS ±5 [3.66± 0.2] CDS 100 Ø 8 [0.31] Ø 8 [0.31] CDS [0.251] 8.4 [0.331] CDS [0.81] 8.3 [0.33] 20 [0.79] Note: djustable in both directions. F J Spring centered, floatation spool Note: Float body section required 65 CDS 60 [2.56] 78 CDS 100 [3.07] 10 CDS 60 [0.39] 12.5 CDS 100 [0.49] 82 CDS 60 [3.23] 101 CDS 100 [3.97] Float in Float out mm [in] L0564 Revision February 2006 * Default relief setting if not specified

49 CDS 60 and 100 Work section order code (example) Spool centering and detent options (continued) E /40* M Spring offset N wo-position detent: neutral and spool in O wo-position detent: neutral and spool out 32 [1.26] CDS [1.57] CDS [1.26] CDS [1.57] CDS [1.26] CDS [1.57] CDS 100 Spring centered with switch: activates on spool in Q Spring centered with switch: activates on spool in and out R Spring centered with switch: activates two motors CDS [0.26] 8.0 [0.32] CDS CDS 60 [1.26] 40 CDS 100 [1.57] CDS [0.26] 8.0 [0.32] CDS 100 CDS [1.26] CDS [1.57] 6.5 [0.26] CDS [0.32] CDS E 520L0564 Revision February 2006 mm [in] * Default relief setting if not specified 49

50 CDS 60 and 100 uxiliary valves 100 Work section order code (example) 1 E /40* J¹ 11 [0.43] ¹ 11 K² [0.43] 10 [0.39] 1 in 1 in 1 in For 3 ways spools. For valves, C, F, G, and I For valves D and E. ³ 1 in 11/16 7/16 C 67 [2.64] Max 1 in Central body for use with auxiliary valves D 4 47 [1.85] Standard 29 Short version [1.14] (use with electrical actuation) 1 in E 4 1 in 7/8 16 [0.63] 5/8 F 62 [2.44] Max 1 in CDS 60 Knob ¹ Order code H for plastic plug in auxiliary port of 3-way spool and body for valves, C, F, G, and I. G³ 12 [0.47] 1 in 11/16 7/16 ² Order code L for plastic plug in auxiliary port for valve E (flow control L). Order code M for plastic plug in auxiliary port for valve D(pilot retaining). ³ Don t use valves and G with electrical actuation. 4 When using options D and E, electrical actuators must be mounted upside down. mm [in] E L0564 Revision February 2006 I 70 [2.76] Max 1 in 29 [1.14] * Default relief setting if not specified

51 CDS 60 and 100 uxiliary valves (continued) 100 Work section order code (example) 1 E /40* uxiliary valves compatibility C D E F G I J K C D E F G I J K Dimensions CDS 100 Not compatible Compatible Compatible (EXCE electrical) Compatible (ONLY electrical) Y 152 [5.98] 46 [1.81] 30 [1.18] 46 [1.81] 82 [3.23] 38 [1.49] 142 [5.59] 100 [3.94] 25 [0.98] X 25 [0.98] 15 [0.59] 127 [5.00] 10 [0.39] R 5.5 [0.22] t 27 N m 20 lbf ft Reference dimensions Number of X sections 1 95 [3.74] 137 [5.39] [5.47] 181 [7.13] [7.24] 226 [8.89] [9.02] 270 [10.63] [10.75] 314 [12.36] [12.52] 359 [14.13] [14.25] 403 [15.87] [15.98] 448 [17.64] [17.76] 492 [19.37] [19.49] 537 [21.14] [21.26] 581 [22.87] [22.99] 626 [24.65] Y 44.5 [1.75] 520L0564 Revision February 2006 mm [in] * Default relief setting if not specified 51

52 CDS 60 and 100 Dimensions CDS [4.72] 38 [1.50] 24 [0.94] Y 38 [1.50] 56 74* [2.20] [2.91] 119 [4.69] 82 [3.23] 32 [1.26] 14 [0.55] 98 [3.86] 18 [0.71] 18 [0.71] Reference dimensions 26 [1.02] X r. 4.5 [0.18] 28.5 [1.12] t 18 N m 13 lbf ft Number of sections X Y 1 72 [2.83] 112 [4.41] [4.25] 148 [5.83] [5.67] 184 [7.42] [7.09] 220 [8.66] [8.50] 256 [10.08] [9.92] 292 [11.50] [11.34] 328 [12.91] [12.76] 364 [14.33] [14.17] 400 [15.75] [15.59] 436 [17.17] [17.01] 472 [18.58] [18.43] 508 [20.00] 13 [0.51] 36 [1.42] Mounting requirements Flatness [0.02 to 0.03] max Flatness [0.02 to 0.03] max E L0564 Revision February 2006 * Default relief setting if not specified

53 Model 1125 ypical applications Car transport haulers, small backhoes, utility trucks, and mini-excavators Standard features ll valves supplied with clevis end spools ower-beyond port machined and plugged (use whenever a downstream valve is required) Cast-iron body Chrome plated spools select fit to body for leakage control Load-check for each spool to prevent load drop before raise ll porting options machined and plugged Individually boxed and labeled 520L0564 Revision February

Directional Control Valves Technical Information Model 1500

Directional Control Valves Technical Information Model 1500 Single spool monoblock valve. 26.4 l/min [7 US gal/min] maximum flow. 138 bar [2 psi] maximum pressure with relief. 27 bar [3 psi] maximum pressure without relief. Garden tractors, mowers, utility equipment,

More information

DNS. Monoblock directional control valves DNS - Directional control valve

DNS. Monoblock directional control valves DNS - Directional control valve Monoblock directional control valves DNS - Directional control valve DNS efore use, carefully read the GENERL INSRUCIONS FOR USE OF DIRECIONL CONROL VLVES 398SMD6I - 6--8 DNS echnical data Nominal flow

More information

SDM to 8 sections monoblock valve D1WWDA02A

SDM to 8 sections monoblock valve D1WWDA02A SDM 1 SDM1 1 to 8 sections monoblock valve D1WWDA2A SDM1 Additional information This folder shows the product in the most standard configurations. Please contact Sales Dpt. for more detailed information

More information

Function. Valve Size. Pilot Oil. p min. Bold: Designates Tier I products and options.

Function. Valve Size. Pilot Oil. p min. Bold: Designates Tier I products and options. Catalog HY14-255/US echnical Information ilot Operated ressure Reducing Valves Series VMY*6 General Series VMY*6 valves consist of the main stage with valve spools and the pilot stage with the proportional

More information

Fitted with a main pressure relief valve and a load check valve on every working section.

Fitted with a main pressure relief valve and a load check valve on every working section. SDS18 1 to 12 sectional directional control valve Fitted with a main ressure relief valve and a load check valve on every working section. Available with arallel and series-arallel (tandem) circuit. Otional

More information

Monoblock directional control valves ML - Directional control valve

Monoblock directional control valves ML - Directional control valve Monoblock directional control valves ML - Directional control valve ML Before use, carefully read the GENERAL INSRUCIONS FOR USE OF DIRECIONAL CONROL VALVES 398SMD4I - 6--8 ML echnical data Nominal flow

More information

PTS1120TSJB PTS2120TSTSJB

PTS1120TSJB PTS2120TSTSJB Engineering & Manufacturing Solutions Specifications: 18 gpm (68.0 lpm) Nominal Capacity. Rated up to 3000 psi (207 bar). Port Sizes: -Inlet/Outlet #12 SAE. -Work Ports #10 SAE. 10 Micron Filtration Recommended.

More information

Pilot valve PPCD04-PPRV DATA SHEET

Pilot valve PPCD04-PPRV DATA SHEET CLSSIC ilot valve CD4-RV D SHEE 294 297 Description SVB pilot valve is a small smooth valve, based on homas Magnetes propotional pressure reducing valve, that controls a limited-flow control feed to a

More information

R S 280 is a modular parallel sect. Directional Control Valve RS RS In relation to its flow capacity its installation

R S 280 is a modular parallel sect. Directional Control Valve RS RS In relation to its flow capacity its installation Directional Control Valve RS 280 3 RS 2802 3102RS28001 R S 280 is a modular parallel sect nal valve. Suitable applications are medium sized and big truck loaders, medium sized backhoe loaders and other

More information

Auxiliary valve QDS6 Sequence valve, 3-way. Catalogue (GB) (US) October 1998

Auxiliary valve QDS6 Sequence valve, 3-way. Catalogue (GB) (US) October 1998 Auxiliary valve Sequence valve, 3-way Catalogue 9129 8542-02 (GB) 9129 8542-06 (US) October 1998 Sequence valve, 3-way Applications The sequence valve is designed to open or close a hydraulic pilot signal

More information

Flow Control Valves. 1 Description. 2 Symbols. Series MTKA, MTQA, MTCA 2.1 MTKA MTQA flow control valve. 1.1 MTKA flow control valve

Flow Control Valves. 1 Description. 2 Symbols. Series MTKA, MTQA, MTCA 2.1 MTKA MTQA flow control valve. 1.1 MTKA flow control valve Flow Control Valves Series MTK, MTQ, MTC MTQ... MTC... robust, uncomplicated, reliable these valves do not require maintenance. This lowers costs and reduces the risk of a system failure. can be provided

More information

1 LS unloading (control valve, orifice, none) 2 LS max pressure relief. 3 Spool type

1 LS unloading (control valve, orifice, none) 2 LS max pressure relief. 3 Spool type Flow Control Valve Series LVM.. high flow rates (8 l/min) flow rates are unaffected by temperature change or when the higher load pressure alternates between the outlet ports proportional flow-sharing

More information

Directional Controls

Directional Controls Vickers Directional Controls Lever Operator Directional Control Valves DG17S-8-**-10 DG17S4-10 **-50 NF D08/D10, ISO-4401-08/10 Released 5/94 681 able of Contents General Information..................................................................................

More information

BW0500AO. ByWire Elements BW0500AO Element 4/3 with side ports IBW0500 Interface

BW0500AO. ByWire Elements BW0500AO Element 4/3 with side ports IBW0500 Interface ywire Elements Element 4/3 with side ports IW5 Interface efore use, carefully read the GENERL INSTRUCTIONS FOR USE OF DIRECTIONL CONTROL VLVES 398SW5EN - 5--8 Technical data Nominal flow 5 l/min 3. US

More information

Xpress L90LS Directional Control Valve. Catalog HY /UK December, 2001

Xpress L90LS Directional Control Valve. Catalog HY /UK December, 2001 Xpress L90LS Directional Control Valve Catalog HY17-8525/UK December, 2001 Catalogue HY17-8525/UK Technical Information Xpress - general information Xpress is a valve-customization service that enables

More information

VICKERS. SystemStak Valves. ISO ; NFPA-D03; 315 bar (4500 psi); 60 L/min (15.7 USgpm) GB 2027B

VICKERS. SystemStak Valves. ISO ; NFPA-D03; 315 bar (4500 psi); 60 L/min (15.7 USgpm) GB 2027B VICKERS SystemStak Valves ISO 441-3; NF-D3; 315 bar (45 psi); 6 L/min (15.7 USgpm) 1 G 227 uild a Compact, Cost-Effective, Reliable Hydraulic System with Vickers SystemStak Valves Reduces System Space

More information

LV LOADER DIRECTIONAL CONTROL VALVES INSTALLATION & USER GUIDE

LV LOADER DIRECTIONAL CONTROL VALVES INSTALLATION & USER GUIDE LV LOADER DIRECTIONAL CONTROL VALVES INSTALLATION & USER GUIDE SPECIFICATIONS: 10 gpm (38 lpm) Nominal Capacity. Rated up to 4000 psi (275 bar). Port Sizes-Inlet/Outlet #8SAE (3/4-16). Work Ports #8SAE

More information

005 Series Modular Valves

005 Series Modular Valves 5 Series Modular Valves ype of Modular Valve Class Graphic Symbols age Solenoid Operated Directional Valve DSG-5- *** - * - ressure Control Valves Flow Control Valves Directional Control Valves Modular

More information

Load Controls Screw In Cartridge Valves Pressures to 350 bar (5000 psi) Flows to 190 l/min (50 USgpm)

Load Controls Screw In Cartridge Valves Pressures to 350 bar (5000 psi) Flows to 190 l/min (50 USgpm) Vickers Cartridge Valves Load Controls Screw In Cartridge Valves Pressures to 50 bar (5000 psi) Flows to 90 l/min (50 USgpm) Rev. 2/99 722 Contents MODEL DESCRIPTION TYP. APPLICATION PRESSURE bar (psi)

More information

directional control valve series cv691

directional control valve series cv691 directional control valve series cv691 Contents Page 3 Page 4 Page 5 Page 6-7 Page 8 Page 9 Page 10 Page 11-12 General Information Technical Data Performance Curves Dimensions Relief Valve Advantages

More information

E 212 E 222 Tank top mounting Connection up to G1¼ / -20 SAE Nominal flow rate up to 220 l/min / 58.1 gpm

E 212 E 222 Tank top mounting Connection up to G1¼ / -20 SAE Nominal flow rate up to 220 l/min / 58.1 gpm Return Filters E E Tank top mounting Connection up to G¼ / - SE up to l/min / 8. gpm Description pplication In the return line circuits of hydraulic systems. erformance features rotection against wear:

More information

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R PILOT OPERTED PRESSURE REDUCER VLVE - Series VR4R Veljan Pressure Reducer Valve Series VR4R are pilot operated controls used to control pressure in a secondary part of a hydraulic circuit. Pressure is

More information

Proportional Directional Valve System

Proportional Directional Valve System roportional Directional Valve System Sectional Design and Flow Sharing rinciple Reference: 31--959-EN-3 Stand: 9.216 1/2 2/2 31--959-EN-3/9.216 Contents age 1 General... 5 1.1 Description... 5 1.2 Advantages...

More information

Electrically Operated Pressure-Relief Cartridge, Size 10

Electrically Operated Pressure-Relief Cartridge, Size 10 Electrically Operated Pressure-Relief Cartridge, Size 1 Q max = 14 l/min (37 gpm), p max = bar (5 psi) seated pilot stage, spool-type design, with remote contral port Z Series WUVPOC-2, WUVPLC-2 1 Description

More information

Directional Controls

Directional Controls Vickers Directional Controls Directional Control Valves DG3V-3-*-60 Hydraulic Operated DG17V-3-*-60 Lever Operated DG18V-3-*-60 Air Operated DG20V-3-*-60 Cam Operated DG21V-3-*-60 Plunger Operated CETOP

More information

Directional Control valves

Directional Control valves Chapter 10.1 Chapter 10 Directional Control valves 10.1 Check Valves Figure 10.1 Check valve wo conditions: free flow or "checked" flow Usually has a cracking pressure of 69 a 104 a (10-15 psi) If used

More information

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R PILOT OPERTED PRESSURE REDUCER VLVE - Series VR4R Veljan Pressure Reducer Valve Series VR4R are pilot operated controls used to control pressure in a secondary part of a hydraulic circuit. Pressure is

More information

Check Valves. Pilot Operated Check Valves. Vickers. 4CG-10, 20 Series 4CS-03, 20 Series 4CT-06/10, 20 Series. Basic Characteristics.

Check Valves. Pilot Operated Check Valves. Vickers. 4CG-10, 20 Series 4CS-03, 20 Series 4CT-06/10, 20 Series. Basic Characteristics. Vickers heck Valves Operated heck Valves 4G-10, 20 Series, 20 Series 4T-06/10, 20 Series Typical Section 4T1-06-D*-20-U, illustrating external drain and decompression features asic haracteristics Maximum

More information

Full Range Pressure Compensating Variable Flow Control

Full Range Pressure Compensating Variable Flow Control Engineering & Manufacturing Solutions Specifications: See flow chart for capacity. Rated for 3000 psi (207 bar). Weighs 7- ¾ lbs. (3.52 kg). 30-Micron Filtration Recommended. Torque to turn side lever

More information

E 328 E 498 Tank top mounting Connection up to G1½ / -24 SAE and SAE 2 Nominal flow rate up to 600 l/min / gpm

E 328 E 498 Tank top mounting Connection up to G1½ / -24 SAE and SAE 2 Nominal flow rate up to 600 l/min / gpm Return-Suction Filters E 8 E 98 Tank top mounting Connection up to G½ / - SE and SE Nominal flow rate up to 6 l/min / 8. gpm Description pplication For operation in units with hydrostatic drives, when

More information

4/3 Directional valve elements L8_P5 with proportional (ED-IP) control and with or without LS connections L8_P5 (ED-IP)

4/3 Directional valve elements L8_P5 with proportional (ED-IP) control and with or without LS connections L8_P5 (ED-IP) 4/3 Directional valve elements L8_5 with proportional (ED-I) control and with or without LS connections L8_5 (ED-I) RE 1831-7 Edition: 2.21 Replaces: 7.12 7.212 Size Series Maximum operating pressure 31

More information

2-way flow control valve Model 2FRM 6

2-way flow control valve Model 2FRM 6 R 28 6/0.98 Replaces R 28 62/05.94 R 28 6/06.98 2-way flow control valve Model 2FRM 6 Nominal size 6 Series X Maximum operating pressure 4569 SI (5 bar) ) Maximum flow 8.45 GM (2 L/min) H//D 585/97 + H//D

More information

Monoblock Directional Control Valve RMB 202

Monoblock Directional Control Valve RMB 202 Monoblock Directional Control Valve RMB 202 Key valve features RMB 202 is a 2-section mono block valve, especially designed for front-end loaders. The valve is prepared for quick connecting couplings,

More information

Pressure reducing valve, pilot operated, Model 3DR

Pressure reducing valve, pilot operated, Model 3DR RA 26 928/06.98 Pressure reducing valve, pilot operated, Model 3DR Nominal size 16 Series 5X Maximum operating pressure 3600 PSI (250 bar) Maximum flow 58.1 GPM (220 L/min) Contents Description Page Features

More information

Inverse Proportional Pressure-Relief Cartridge, Size 10

Inverse Proportional Pressure-Relief Cartridge, Size 10 Inverse Proportional Pressure-Relief Cartridge, Size 1 Q max = 12 l/min, p max = 3 bar Seated pilot, spool-type main stage, damped design 1 Description inverse-proportional pressure-relief valves are size

More information

L125 SERIES POST-COMPENSATED SECTIONAL LOAD SENSE VALVE

L125 SERIES POST-COMPENSATED SECTIONAL LOAD SENSE VALVE L15 SERIES POST-COMPENSATED SECTIONAL LOAD SENSE VALVE TAKE CONTROL Take control with Muncie Power Products L15 directional control valve. The L15 is constructed with high-grade, iron castings and nickel-plated

More information

Leak-Free Load-Control Valve SAE ½ psi flange

Leak-Free Load-Control Valve SAE ½ psi flange Leak-Free Load-Control Valve SE ½ - 6000 psi flange Q max = 150 l/min [40 gpm], p max = 420 bar [6000 psi] leak-proof, two-stage hydraulic, SE-flange design 12--S... 1 Description Two-stage load-control

More information

Cover headline. Cover subheadline. Check Valves

Cover headline. Cover subheadline. Check Valves Check Valves Cover headline Direct and pilot operated check valve functions for applications up to 5 bar (5 psi) and 7 L/min (6 USgpm) Cover subheadline EATON Screw-In Cartridge Valves E-VLSC-MC-E December

More information

Cartridge Valves Technical Information. Pressure Reducing, Quick Reference

Cartridge Valves Technical Information. Pressure Reducing, Quick Reference Quick Reference Pressure Reducing, Non-Relieving Model No. Description Flow* Pressure Page CP20-2 PRC 06 SDC10- NCS06/ Pressure Reducing, Non-Relieving, Direct Acting 40 l/min [10 US gal/min] 40 l/min

More information

Logic Elements Screw-in Cartridge Valves Pressures to 290 bar (4200 psi) Flows to 303 l/min (80 USgpm)

Logic Elements Screw-in Cartridge Valves Pressures to 290 bar (4200 psi) Flows to 303 l/min (80 USgpm) Vickers artridge Valves Logic Elements Screw-in artridge Valves Pressures to 9 bar ( psi) Flows to l/min (8 USgpm) Revised 9/98 7 ontents MODEL DESRIPTION TYPIL PPLITION PRESSURE bar (psi) RTED FLOW l/min

More information

Pressure Reducing Valves Catalog Quick Reference

Pressure Reducing Valves Catalog Quick Reference Quick Reference Pressure Reducing, Non-Relieving Model No. Description Flow* Pressure Page 2 CP20-2 SDC0- Pressure Reducing, 20 bar PR - 5 PRC 06 NCS06/ Non-Relieving, Direct Acting [000 psi] 5 bar [4500

More information

Orbital Motors Type OMP X and OMR X

Orbital Motors Type OMP X and OMR X Technical Information Orbital Motors Type OMP X and OMR X powersolutions.danfoss.com Revision history Table of revisions Date Changed Rev January 218 Major revision. 21 February 217 First edition. 11 2

More information

SystemStak Valves. ISO4401 Size 02

SystemStak Valves. ISO4401 Size 02 SystemStak Valves ISO441 Size 2 Reduce System Space Requirements SystemStak valves make compact hydraulic systems in which specific function valves are sandwich mounted between a directional valve and

More information

Prop. 3-Way Pressure-Reducing Cart., Size 5 / SAE 08

Prop. 3-Way Pressure-Reducing Cart., Size 5 / SAE 08 Prop. -Way Pressure-Reducing Cart., Size / SAE 8 Q max = 1 l/min (4 gpm), p max = bar (6 psi) Direct acting, electrically operated 1 Description proportional -way pressure-reducing cartridges are size

More information

Pressure reducing valve, pilot operated

Pressure reducing valve, pilot operated Pressure reducing valve, pilot operated RE 26928/09.07 Replaces: 10.97 1/8 Type 3DR Size 16 Component series 5X Maximum operating pressure 250 bar Maximum flow 220 l/min H5844 Table of contents Content

More information

INVERS. Solenoid coil 24VDC 12 VDC Exm Exd Explosion protection marking:

INVERS. Solenoid coil 24VDC 12 VDC Exm Exd Explosion protection marking: direct operated INVERSE function available Q max = 2 l/min p max = bar INVERS Description EPDB The direct operated proportional pressure relief valve is built as a slip-in cartridge fitted in a connecting

More information

E 084 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 80 l/min / 21.1 gpm

E 084 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 80 l/min / 21.1 gpm Return-Suction Filters E 08 Tank top mounting Connection up to G / -6 SE Nominal flow rate up to 80 l/min /. gpm Description pplication For operation in units with hydrostatic drives, when the return flow

More information

MPS/MST SPIN - ON FILTER SUCTION - RETURN SERIES. Maximum working pressure 12 bar. Flow rates to 300 l/min

MPS/MST SPIN - ON FILTER SUCTION - RETURN SERIES. Maximum working pressure 12 bar. Flow rates to 300 l/min MPS/MST SERIES SPIN - ON FILTER SUCTION - RETURN Maximum working pressure 1 bar Flow rates to l/min D e s c r i p t i o n MPS/MST The spin-on filter series is a complete product range suitable, for both

More information

E 328 E 498 Tank top mounting Connection up to G1½ and SAE 2 Nominal flow rate up to 600 l/min

E 328 E 498 Tank top mounting Connection up to G1½ and SAE 2 Nominal flow rate up to 600 l/min Return-Suction Filters E 8 E 98 Tank top mounting Connection up to G½ and SE Nominal flow rate up to 6 l/min Description pplication For operation in units with hydrostatic drives, when the return flow

More information

3-Way Pressure-Reducing Cartridge, Size 2 4

3-Way Pressure-Reducing Cartridge, Size 2 4 -Way Pressure-Reducing Cartridge, Size 2 Q max = 2 l/min, p max = 25 bar Spool-type design, direct acting, with manual adjustment 1 Description Compact construction for cavity type AM /- UNF to Bucher

More information

MODULES. Maximum Flow U.S.GPM. Max. Operating Pressure MPa (PSI) L/min. 005 Series 25 (3630) Modular Valves. 01 Series 31.

MODULES. Maximum Flow U.S.GPM. Max. Operating Pressure MPa (PSI) L/min. 005 Series 25 (3630) Modular Valves. 01 Series 31. F MODULES YUKEN's Modular Valves are stack type valves, and require no piping. hey not only rationalise system build, but they also meet the technical requirements for a variety of hydraulic systems. Stacking

More information

Digital directional & flow control valves D-DF(R)G

Digital directional & flow control valves D-DF(R)G Digital directional & flow control valves D-DF(R)G Functional Symbols Model Code D-DFG- D-DFG-~ D-DFRG-/ D-DFG--C--- Digital directional & flow control valve Size Spool type (neutral position) : ll ports

More information

Pressure reducing valve, direct operated

Pressure reducing valve, direct operated Electric Drives and Controls Table of contents Hydraulics Pressure reducing valve, direct operated Model DR 10 DP Nominal size 10 Series 4X Maximum reduced pressure 210 bar (3050 PSI) Maximum flow 80 L/min

More information

Proportional Pressure-Relief Cartridge Valve, Size 2...4

Proportional Pressure-Relief Cartridge Valve, Size 2...4 Proportional Pressure-Relief Cartridge Valve, Size... Q max = l/min (6 gpm), p max = bar (58 psi) Direct acting, electrically operated Description proportional pressure-relief valves are direct acting

More information

Cooler-Bypass Thermostat Valve, Size 16

Cooler-Bypass Thermostat Valve, Size 16 Cooler-Bypass hermostat Valve, Size Q max = l/min, p max = bar emperature-controlled, integral relief function, various pressure settings available Description emperature-dependent bypass control Integral

More information

E 094 E 103 E 143 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 135 l/min / 35.7 gpm

E 094 E 103 E 143 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 135 l/min / 35.7 gpm Return Filters E 9 E E Tank top mounting Connection up to G / -6 SAE Nominal flow rate up to 5 l/min / 5.7 gpm Description Application In the return line circuits of hydraulic systems. Performance features

More information

Auxiliary Valve QDS6 Sequence Valve, 3-way. Catalogue HY /UK June 2003

Auxiliary Valve QDS6 Sequence Valve, 3-way. Catalogue HY /UK June 2003 Auxiliary Valve equence Valve, 3-way Catalogue HY17-8542/UK June 2003 General ubject to alteration without prior notice. he curves and diagrams in this catalogue are typical examples only. While the contents

More information

Cartridge Valves Technical Information. Pilot operated check valves. Quick reference

Cartridge Valves Technical Information. Pilot operated check valves. Quick reference Quick reference Pilot to Open Model No. Description Flow* Pressure Page P RPC 4 NCS4/ Pilot Operated Check Valve, Pilot to Open l/min [ US gal/min] RPC 6 NCS6/ 5 l/min [7 US gal/min] CP45- SDC- l/min RPC

More information

shutoff valves 900 Series psig Manual Shutoff Valves

shutoff valves 900 Series psig Manual Shutoff Valves 0 6000 psig Manual Shutoff Valves Features Zero leakage Protected o-ring Full flow passages Freedom from wire drawing Panel mount standard Hand wheel or toggle handle How it Works Closed O-ring seal on

More information

Inverse Prop. Pressure-Relief Cart., Size 2 4

Inverse Prop. Pressure-Relief Cart., Size 2 4 Inverse Prop. Pressure-Relief Cart., Size Q max = l/min (6 gpm), p max = bar (58 psi) Direct acting, electrically operated Description inverse proportional pressure-relief valves are direct acting screw-in

More information

Fluid: Standard Hydraulic Oil F (49 C) Flow, Horsepower and Efficiency Charts Efficiency - % Power. Flow 113.

Fluid: Standard Hydraulic Oil F (49 C) Flow, Horsepower and Efficiency Charts Efficiency - % Power. Flow 113. Catalog HY13-5-2/US echnical Information erformance Data V Series iston umps ump Model Displacement 3 CC/REV (IN /REV) ump Delivery @ bar (1 SI) in LM (GM) RM 1 RM V6 6 (4.6) 91.2 (24.1) 134.4 (35.5) V1

More information

Intrinsically safe solenoid valves on/off controls - ATEX certification

Intrinsically safe solenoid valves on/off controls - ATEX certification www.atos.com Table E130-17/E Intrinsically safe solenoid valves on/off controls - ATEX certification valve body valve spool intrinsically safe solenoid electrical connector manual override DHW-0611/WP/6

More information

MOUNTING SURFACE MOUNTING POSITION MAXIUMUM OPERATING PRESSURE FLUID OPERATING VISCOSITY FLUID CLEANLINESS HYSTERESIS REPEATABILITY THRESHOLD VOLTAGE

MOUNTING SURFACE MOUNTING POSITION MAXIUMUM OPERATING PRESSURE FLUID OPERATING VISCOSITY FLUID CLEANLINESS HYSTERESIS REPEATABILITY THRESHOLD VOLTAGE TYPICAL PERFORMANCE SPECIFICATIONS DESCRIPTION These proportional valves are direct operated pressure reducing valves. They can be used to control pressure in parts of a circuit. This valve incorporates

More information

Fixed Displacement Plug-In Motor A2FE

Fixed Displacement Plug-In Motor A2FE www.phphyds.com Series 6, axial tapered piston, bent axis design for mounting in mechanical gearboxes Sizes 28...355 Nom. Pressure up to 400 bar Peak Pressure up to 450 bar he fixed displacement plug-in

More information

VACUUM REGULATORS CONTENTS

VACUUM REGULATORS CONTENTS CAD drawing data catalog is available. ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS CONTENTS Small Regulators Features 759 Specifications, Order Codes, Flow Rate

More information

Flow Controls. DG**-06 Series Stacking Valves. Vickers. ISO (D06) Interface Flows to 340 l/min (90 USgpm) Pressure to 210 bar (3000 psi)

Flow Controls. DG**-06 Series Stacking Valves. Vickers. ISO (D06) Interface Flows to 340 l/min (90 USgpm) Pressure to 210 bar (3000 psi) Vickers Flow Controls DG**-6 Series Stacking Valves ISO-441-8 (D6) Interface Flows to 34 l/min (9 USgpm) Pressure to 21 bar (3 psi) 5125./EN/598/A Introduction These stackable modules are designed for

More information

Directional Control Valve P70

Directional Control Valve P70 Directional Control Valve Open or Closed Centre Proportional Valve Series Catalogue HY17-8546/UK January, 2007 Catalogue Information Catalogue layout This catalogue is designed to give an overview of the

More information

Pressure relief valve, direct operated

Pressure relief valve, direct operated ressure relief valve, direct operated R 25402/05.0 Replaces: 10.05 /1 ype DBD Nominal sizes to 0 Component series 1X Maximum operating pressure 0 bar Maximum flow 0 l/min H5585 Overview of contents Contents

More information

Inverse Proportional Pressure-Relief Cart., Size 2 4

Inverse Proportional Pressure-Relief Cart., Size 2 4 Inverse Proportional Pressure-Relief Cart., Size Q max = l/min, p max = 5 bar Direct acting, electrically operated 1 Description inverse proportional pressure-relief valves are direct acting screw-in cartridges

More information

Check valve hydraulically pilot operated

Check valve hydraulically pilot operated Check valve hydraulically pilot operated RE 6/7.5 Replaces:. / Types SV and SL Nominal sizes to Component series X Maximum operating pressure 5 bar Maximum flow 55 l/min H555 Overview of contents Contents

More information

Proportional Pressure-Relief Cartridge Valve, Size 2...4

Proportional Pressure-Relief Cartridge Valve, Size 2...4 Proportional Pressure-Relief Cartridge Valve, Size... Q max = l/min, p max = 3 bar Direct acting, electrically operated 1 Description proportional pressure-relief valves are direct acting screw-in cartridges

More information

Inverse Proportional Pressure-Relief Cart., Size 2 4

Inverse Proportional Pressure-Relief Cart., Size 2 4 Inverse Proportional Pressure-Relief Cart., Size Q max = l/min, p max = 35 bar Direct acting, electrically operated Description Compact construction for cavity type AL 3/-6 UNF Operated by a proportional

More information

3-Way Safety Block DSV

3-Way Safety Block DSV 3-Way Safety Block DSV DSV 10 - M DSV 10 - M - T-ball DSV 10 - EY 1. Description 1.1. GENERAL The 3-way safety block is used to shut off and discharge hydraulic accumulators or consumers. It complies with

More information

Directional Control Valve P70 Open or Closed Centre Proportional Valve Series. Catalogue HY /UK July, 2005

Directional Control Valve P70 Open or Closed Centre Proportional Valve Series. Catalogue HY /UK July, 2005 Directional Control Valve Open or Closed Centre Proportional Valve Series Catalogue HY17-8546/UK July, 2005 Catalogue Information Catalogue layout This catalogue is designed to give an overview of the

More information

Pump safety block. Type DBA, DBAW, DBAE(E) Features. Contents. RE Edition: Replaces: 11.10

Pump safety block. Type DBA, DBAW, DBAE(E) Features. Contents. RE Edition: Replaces: 11.10 ump safety block ype D, DW, DE(E) RE 25891 Edition: 2013-05 Replaces: 11.10 Size 16, 25, 32 Component series 2 Maximum operating pressure 350 bar Maximum flow 400 l/min H5872 Features Depressurized start-up

More information

Pilot Operated Check Valves Catalog Quick Reference

Pilot Operated Check Valves Catalog Quick Reference Quick Reference Pilot to Open Model No. Description Flow* Pressure Page RPC NCS/3 Pilot Operated Check Valve, Pilot to Open.5 l/min [5. US gal/min] RPC NCS/3 35 l/min [9.3 US gal/min] CP5- SDC-3 3 l/min

More information

PLD 03 T A CASAPPA S.p.A.

PLD 03 T A CASAPPA S.p.A. GEAR FLOW DIVIDERS INDEX Section Page GENERAL FEATURES... 3 GENERAL DATA... 5 FLOW EQUALIZER... 6 FLOW DIVIDERS... 8 TYPICAL CIRCUITS... 10 NOTES ABOUT COMPOSITION... 12 PORTS DIMENSIONS.... 14 GROUP DIMENSIONS...

More information

OP11 OVERALL SPECIFICATIONS

OP11 OVERALL SPECIFICATIONS The Directional Valve Series provides a compact range of manually operated directional valves for low flow applications. Because of the physical size of valves are ideally suited for mounting on small

More information

Leak free Pipe Rupture Valve for Excavators

Leak free Pipe Rupture Valve for Excavators Leak free Pipe Rupture Valve for xcavators Series motion and progress Reference: 3 P 9575 1/11.6 Classification: 43.325.355...325.35 1/17 Contents Page 1 General description................................................................

More information

Orbital Motors Type OMP, OMR and OMH. Technical Information

Orbital Motors Type OMP, OMR and OMH. Technical Information Orbital Motors Type OMP, OMR and OMH Technical Information OMP, OMR and OMH Contents Revision View Date Page Changed Revision Mar 26 Small updates B Jun 27 all Major revision with new lit-number (minus

More information

Directional Control Valve L90LS Proportional, Load-Sensing and Pressure Compensated. Catalogue HY /UK July, 2005

Directional Control Valve L90LS Proportional, Load-Sensing and Pressure Compensated. Catalogue HY /UK July, 2005 Directional Control Valve Proportional, Load-Sensing and Pressure Compensated July, 2005 Catalogue Information Catalogue layout In addition to general information and basic technical data, this catalogue

More information

Desiccant Air Breathers DBE. Section 3: TNK SCHROEDER INDUSTRIES ACCESSORIES 21

Desiccant Air Breathers DBE. Section 3: TNK SCHROEDER INDUSTRIES ACCESSORIES 21 Desiccant Air Breathers DBE Section 3: SCHROEDER INDUSTRIES ACCESSORIES 21 Reservoir Accessories A hydraulic systems reservoir can play a significant role in the ingression of contamination into the system.

More information

Leak-Free Load-Control Valve, Size 20

Leak-Free Load-Control Valve, Size 20 Leak-Free Load-Control Valve, Size 20 Qmax = 350 l/min [92 gpm], pmax = 420 bar [6000 psi] leak-proof, two-stage hydraulic, manifold mounting 20--P... 1 Description Whenever large loads are to be precisely

More information

Pressure reducing/relief valve, pilot operated type UZCP10

Pressure reducing/relief valve, pilot operated type UZCP10 ressure reducing/relief valve, pilot operated type UZC10 NS10 up to 1, Ma up to 80 dm /min D SHEE - OER RION MNU NUL WK 420 280 07.2014 LICION he pressure reducing/relief valve type UZC10 pilot operated

More information

Orbital Motors Type VMP. Technical Information

Orbital Motors Type VMP. Technical Information Orbital Motors Type VMP Technical Information A Wide Range of Orbital Motors Revision View Date Page Changed Revision May 213 All First edition AA F31 245 A Wide Range of Orbital Motors Sauer-Danfoss is

More information

180 Series Rotary Shear Directional Control Valve

180 Series Rotary Shear Directional Control Valve 180 Series Rotary Shear Directional Control Valve Up to l 38 lpm, 10 US gpm l 700 bar, 10,000 psi Milwaukee, WI 53235, US el: +1 (414) 769-6400 sales-us@webtec.com St. Ives, Cambs. E27 3LZ, UK el: +44

More information

MECHANICALLY OPERATED DIRECTIONAL VALVES Rotary Type : DRT/DRG-02 Cam Operated : DCT/DCG-01, 03 Threaded Connection/Sub-plate Mounting

MECHANICALLY OPERATED DIRECTIONAL VALVES Rotary Type : DRT/DRG-02 Cam Operated : DCT/DCG-01, 03 Threaded Connection/Sub-plate Mounting MCHNICLLY ORD VLVS Rotary ype : DR/DRG- Cam Operated : DC/DCG-, hreaded Connection/ Mounting General Information Up to 5 Ma (6 SI), L/min (6. U.S.GM) ub. C-6 hese valves are chiefly used to shift the pilot

More information

Sauer Danfoss Series 90 Hydraulic Axial Piston Pump

Sauer Danfoss Series 90 Hydraulic Axial Piston Pump Sauer Danfoss Series 90 Hydraulic Axial Piston Pump www.hydpump.com 90R030, 90R042, 90R055, 90R075, 90R100, 90R130, 90R180, 90R250 90L030, 90L042, 90L055, 90L075, 90L100, 90L130, 90L180, 90L250 Series

More information

Pressure relief valve, direct operated Type DBD

Pressure relief valve, direct operated Type DBD Industrial Hydraulics Electric Drives and Controls Linear Motion and Assembly echnologies neumatics Service Automation Mobile Hydraulics RE 25 402/06.02 Replaces: 03.98 Material No.: 00772632a ressure

More information

Pilot operated pressure relief valve sandwich plate,type ZDB/Z2DB6 Huade América 1

Pilot operated pressure relief valve sandwich plate,type ZDB/Z2DB6 Huade América 1 Pilot operated pressure relief valve sandwich plate,type ZDB/Z2DB6 Huade América 1 BEIJING HUADE HYDRAULIC INDUSTRIAL GROUP CO.,LTD. Pilot operated pressure relief valve sandwich plate,type ZDB/Z2DB6 Size

More information

DK ton, Double-acting, Die-type Crimping Tool

DK ton, Double-acting, Die-type Crimping Tool INSTRUCTION MANUAL DK6040 60-ton, Double-acting, Die-type Crimping Tool Read and understand all of the instructions and safety information in this manual before operating or servicing this tool. Register

More information

Proportional Valve Group PVG 32 minibooster

Proportional Valve Group PVG 32 minibooster Technical Information Proportional Valve Group powersolutions.danfoss.com Revision history Table of revisions Date Changed Rev February 2018 Add new modules 0201 August 2015 Drawing updated 00.04 February

More information

Proportional Relief Valves

Proportional Relief Valves www.swagelok.com Proportional Relief Valves R Series Liquid or gas service Set pressures from 10 to 6000 psig (0.68 to 413 bar) 1/4 and 1/2 in. and 6 to 12 mm end connections 2 Proportional Relief Valves

More information

Pressure reducing valve, direct operated

Pressure reducing valve, direct operated Electric Drives and Controls Table of contents Hydraulics Pressure reducing valve, direct operated Model ZDR 6 D Nominal size 6 Series 4X Maximum operating pressure 20 bar (3050 PSI) Maximum flow 50 L/min

More information

Size 10 (D05) p max 320 bar (4600 PSI) Technical Features. Technical Data. Port dimensions ZB10A(B) SMT_0019 ZB K -

Size 10 (D05) p max 320 bar (4600 PSI) Technical Features. Technical Data. Port dimensions ZB10A(B) SMT_0019 ZB K - ase late with with ressure Relief Valve for Serial lates ssemblies Z0 Size 0 (D05) p max 320 bar (4600 SI) echnical Features ank cover mounted base manifold for hydraulic power packs which require one

More information

4/3 Directional valve elements L85L1...(EDC-LV) with manual lever operated control with flow sharing control (LUDV concept) L85L1...

4/3 Directional valve elements L85L1...(EDC-LV) with manual lever operated control with flow sharing control (LUDV concept) L85L1... 4/3 Directional valve elements L8L1...(EDC-LV) with manual lever operated control with flow sharing control (LUDV concept) L8L1...(EDC-LV) RE 1831-17 Edition: 2.216 Replaces: 7.12 Size 6 Series Maximum

More information

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R PILOT OPERTED PRESSURE REDUCER VLVE - Series VR4R Veljan Pressure Reducer Valve Series VR4R are pilot operated controls used to control pressure a secondary part of a hydraulic circuit. Pressure is mataed

More information

Industrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US

Industrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US Industrial Hydraulic Valves Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories Catalog HY14-2500/US Industrial Hydraulic Valves WARNING USR RSPONSIBILITY FAILUR OR IMPROPR

More information

Over-center valves type LHT with oscillation damping, zero leakage

Over-center valves type LHT with oscillation damping, zero leakage Over-center valves type LHT with oscillation damping, zero leakage Flow rate Q max = 250 lpm Operation pressure p max = 450 bar See also: o Over-center valve type LHK acc. to D 7100 o Over-center valve

More information

APPLICATION. Conveyors Metal working machines Machines for agriculture Road building machines Mining machinery Food industries

APPLICATION. Conveyors Metal working machines Machines for agriculture Road building machines Mining machinery Food industries HYDRAULIC APPLICATION Conveyors Metal working machines Machines for agriculture Road building machines Mining machinery Food industries Special vehicles Plastic and rubber machinery etc. CONTENTS Specification

More information