Empower. Reclaim your power. Information for technicians. Empower Ottobock 1

Size: px
Start display at page:

Download "Empower. Reclaim your power. Information for technicians. Empower Ottobock 1"

Transcription

1 Empower Reclaim your power. Information for technicians Empower Ottobock 1

2 Empower Powered propulsion for more freedom in life The Empower is an innovation in the field of prosthetic feet. It is equipped with an active ankle joint, making it the only prosthesis with powered propulsion. The Empower is characterized by the following clinically proven features: Power Emulates the function and power of lost muscles and tendons 1,2 Provides energy instead of taking it away even up ramps, hills and stairs 1,6 Control Life-like ankle movement that normalises userʼs walking gait 4 Reduces joint forces which may result in less pain and fewer long-term orthopedic problems 1,2,5,6 Stability Adjusts ankle power, resistance and flexion in real-time Provides balance on variable terrain 3 1. Herr H., Grabowski A. (2012): Bionic ankle-foot prosthesis normalizes walking gait for persons with leg amputation, Proc Biol Sci. Vol. 7, 279(1728): Ferris A., Aldridge J., Sturdy J., Wilken J. (2011): Evaluation of the Biomimetic Properties of a New Powered Ankle-Foot Prosthetic System, Dept. of Orthopedics and Rehabilitation, Center for the Intrepid, Brooke Army Medical Center, Fort Sam Houston, TX, USA. Presented at American Society of Biomechanics. 3. Gates D., Aldridge J., Wilken J. (2013): Kinematic comparison of walking on uneven ground using powered and unpowered prostheses, Clinical Biomechanics, 28, Aldridge J., Ferris F., Sturdy J., Wilken J. (2012): Kinematics and Kinetics with a Powered Lower Leg System During Stair Climbing Ascent Following Transtibial Amputation, Gait & Posture, Vol. 36, Grabowski A., D Andrea S. (2013): Effects of a powered ankle-foot prosthesis on kinetic loading of the unaffected leg during level-ground walking, Neuroeng Rehabil., 10: Esposito E., et al. (2015): Step-to-step transition work during level and inclined walking using passive and powered ankle-foot prostheses, Prosthet Orthot Int. 2 Ottobock Empower

3 Empower Ottobock 3

4 Empower Functions and Benefits Increased energy and less fatigue to walk farther and faster The Empower replaces the function and power of lost muscles and tendons, giving users energy rather than taking it away even up ramps, hills and stairs. Its powered propulsion drives the user forward and upward while smoothly transitioning weight to the remaining limb. The Empower provides the required amount of energy needed for each step, enabling users to cope effortlessly with longer distances, stairs and sloping terrain. Improved safety and stability on different terrain To ensure a smooth rollover of the foot, the Empower decelerates the body at heel strike before accelerating again for toe-off. At the same time, the amount of plantar flexion is adjusted to the slope of terrain. The system uses high resolution sensors to determine the correct amount of ankle power, resistance and flexion in real-time. This helps the user maintain balance and to cope better with variable terrain. Gentler on joints Many users suffer from painful joints as a result of changing their gait pattern. Unbalanced movement patterns and compensatory movements can even lead to osteoarthritis. With its active powered propulsion, the Empower improves the user s gait pattern and reduces the adduction moment. This aids in preventing pain and incorrect gait patterns. 4 Ottobock Empower

5 Empower Ottobock 5

6 Empower Details 360 top cap access The pyramid adapter enables a quick and easy fitting. Ankle Display The power button and battery indicator lights reflect the state of charge are located in front of the Ankle. Dynamic Adaptation Intrinsic control firmware analyzes ankle joint torque and angle data from high resolution sensors, in real-time, to mimic the user s physiological ankle function. Lithium-Polymer Battery The integrated battery lasts for up to 8 hours depending on user activity. The dual bay charger can charge two batteries simultaneously in as little as 90 minutes. Weather sealed components The Ankle is resistant to rain, snow and dirt to withstand the varied demands of everyday life. Powered Propulsion A battery-powered, motorized actuator coupled with a high energy spring provide powered propulsion that emulates the gastrocnemius and soleus muscles. 6 Ottobock Empower

7 Technical data Reference number 1A1-1 Suitable for MG Warranty and service Amputation level Maximum body weight Sizes Weight* Minimum clearance* * Based on size 28 TT, KD, TF 130 kg cm approx. 1,928 g (without footshell) approx. 2,200 g (with footshell) 222 mm The comprehensive warranty package provides your customers with guaranteed mobility for 3 years with no repair costs: 3-year manufacturer's warranty* Free repairs** Free service inspection in month 24 Free service unit during repair and service inspections Scope of delivery The foot comes complete with two rechargeable batteries and a dual bay charger. Software Thanks to tablet-based software, orthopaedic technicians can customise the Empower for each individual user. The software and the tablet are delivered together with the first order. As an alternative, a 6-year warranty package is offered. The warranty can be extended to 6 years at a later date. * Valid for prosthetic foot and charger. The battery is covered by an one year warranty. Wear parts as the footshell are excluded from the warranty. ** Does not cover superficial damage and damage resulting from improper use, intent, negligence, or force majeure. Components & Accessories 1A1-1=* Empower 2F41 Set of heel wedges 2C14=* Footshell incl. 757B38 Battery SL=Spectra Sock Informations 647G1385 Instructions for use 757L38 Charger 757L39 Power Supply BM * EU/GB/US Power cord 560X11=V2 Tuning Device

8 Ottobock 646D1111=EN Technical changes and printing errors reserved.

empower Reclaim your power. Information for technicians empower Ottobock 1

empower Reclaim your power. Information for technicians empower Ottobock 1 empower Reclaim your power. Information for technicians empower Ottobock 1 empower Powered propulsion for more freedom in life The empower Ankle is an innovation in the field of prosthetic feet. It is

More information

3 people 3 unique lifestyles 3 advanced foot solutions

3 people 3 unique lifestyles 3 advanced foot solutions 3 people 3 unique lifestyles 3 advanced foot solutions Reclaim your life Information for practitioners Shelby Hans Intelligent feet are made for more than just walking Today s advanced microprocessor controlled

More information

empower Reclaim your power. Information for users

empower Reclaim your power. Information for users empower Reclaim your power. Information for users Ryan s Story Thinking back to the time when I lost my right leg due to a traumatic injury, I was quite sceptical of what life had in store for me. Using

More information

Meridium. Reclaim your way. Information for clinicians

Meridium. Reclaim your way. Information for clinicians Meridium Reclaim your way. Information for clinicians Reclaim your way. With the development of the individualised Meridium prosthetic foot, Ottobock has incorporated the latest technology to achieve a

More information

1C11 Terion K2. Confidence with every step. Information for Practitioners

1C11 Terion K2. Confidence with every step. Information for Practitioners 1C11 Terion K2 Confidence with every step Information for Practitioners Confidence with every step For prosthesis users who need a high level of stability With the 1C11 Terion K2, Ottobock has developed

More information

1B1 Meridium. Reclaim your way. Information for practitioners. Meridium Ottobock 1

1B1 Meridium. Reclaim your way. Information for practitioners. Meridium Ottobock 1 1B1 Meridium Reclaim your way. Information for practitioners Meridium Ottobock 1 Reclaim your way. With the development of the individualized Meridium prosthetic foot, Ottobock has incorporated the latest

More information

SYMBIONIC LEG 3 INTRODUCTION KEY FEATURES ÖSSUR DYNAMIC SOLUTIONS

SYMBIONIC LEG 3 INTRODUCTION KEY FEATURES ÖSSUR DYNAMIC SOLUTIONS INTRODUCTION Featuring the latest advances in Bionic Technology by Össur, SYMBIONIC LEG 3 is the next generation of integrated prosthetic devices that combines a microprocessor knee and powered microprocessor

More information

Terion 1C10. Back on track. 1C10 Terion Ottobock 1

Terion 1C10. Back on track. 1C10 Terion Ottobock 1 Terion 1C10 Back on track 1C10 Terion Ottobock 1 Terion Back on track There comes a time when you are ready to reclaim your daily routine with everything that goes with it including job, family and friends

More information

1C30 Trias. Moving in harmony. Information for users. 1C30 Trias Ottobock 1

1C30 Trias. Moving in harmony. Information for users. 1C30 Trias Ottobock 1 1C30 Trias Moving in harmony Information for users 1C30 Trias Ottobock 1 Trias Moving in harmony Out and about, going for a stroll, running errands it s important to go where you want without worrying

More information

Your Life. Your Adventure. Triton Family of Products

Your Life. Your Adventure. Triton Family of Products Your Life. Your Adventure. Triton Family of Products Ready for any challenge The search is over! Now your high-mobility patients can choose from a variety of superb options to fit their active lifestyles.

More information

C-Brace Reimbursement Guide

C-Brace Reimbursement Guide Reimbursement Guide Information for practitioners and payers Product Information Effective September 24, 2018 The The is the first microprocessor stance and swing phase controlled orthosis (SSCO ). This

More information

PROPRIO FOOT INTRODUCTION KEY FEATURES ÖSSUR DYNAMIC SOLUTIONS

PROPRIO FOOT INTRODUCTION KEY FEATURES ÖSSUR DYNAMIC SOLUTIONS INTRODUCTION PROPRIO FOOT is an adaptive prosthetic device for low to moderately active below-knee amputees that mimics natural foot motion. Motor-powered ankle motion increases ground clearance and reduces

More information

C-Brace Orthotronic Mobility System

C-Brace Orthotronic Mobility System C-Brace Orthotronic Mobility System You ll always remember your first step Information for practitioners C-Brace Orthotics reinvented Until now, you and your patients with conditions like incomplete spinal

More information

PRO-FLEX. Less load, more dynamics

PRO-FLEX. Less load, more dynamics PRO-FLEX Less load, more dynamics CARBON Unique Pivot Technology and ankle torque deliver 27º ankle motion with progressive stiffness for a more physiological gait. Immediate adaptation to ramps, stairs

More information

Foot System Prosthetist Manual

Foot System Prosthetist Manual Introduction Foot System Prosthetist Manual The Motionfoot is a hydraulic ankle, with a carbon fiber foot plate. It features; Very high ankle range of motion, up to 50. Smooth hydraulic transition from

More information

C-Brace Reimbursement Guide

C-Brace Reimbursement Guide C-Brace Reimbursement Guide Information for practitioners and payers Product Information The C-Brace The C-Brace is the first microprocessor stance and swing phase controlled orthosis (SSCO). This highly

More information

Life Without Limitations

Life Without Limitations Mobility Grades Product Selection Life Without Limitations Presenter: Matt Henderson Ossur Asia Pacific Agenda What is missing? K Level Review Required features for given K Levels A Look at Specific Products

More information

Different by design NEW FEATURES

Different by design NEW FEATURES Different by design Different by design At Össur, we do things differently. The RHEO KNEE design is unique in the MPK market, in that its operating principle is not based on hydraulic technology. Instead

More information

Mechanical Knee Prescription Guide

Mechanical Knee Prescription Guide Mechanical Knee Prescription Guide CONTENTS K1 LOCKING KNEE 1 K1 - K2 BALANCE KNEE OFM1 2 BALANCE KNEE OFM2 3 K2 BALANCE KNEE OM8 4 TOTAL KNEE 1900 5 K2 - K3 OP2 KNEE 6 OP4 KNEE 7 OP5 KNEE 8 OHP3 KNEE

More information

Analysis of ankle kinetics and energy consumption with an advanced microprocessor controlled ankle foot prosthesis.

Analysis of ankle kinetics and energy consumption with an advanced microprocessor controlled ankle foot prosthesis. Analysis of ankle kinetics and energy consumption with an advanced microprocessor controlled ankle foot prosthesis. D.Moser, N.Stech, J.McCarthy, G.Harris, S.Zahedi, A.McDougall Summary This study reports

More information

MOTION FOOT MX. Manual

MOTION FOOT MX. Manual MOTION FOOT MX Manual Real Technology - Real People CONTENTS Intruduction....4 Patient Selection....4 Foot Components....4 Special Precautions....5 Set-Up....6 Change Heel Height & Dorsi Flexion Range....

More information

Prosthetic Solutions for Active Amputees. Andreas Kannenberg, MD, PhD Executive Medical Director North America, Austin, TX, USA

Prosthetic Solutions for Active Amputees. Andreas Kannenberg, MD, PhD Executive Medical Director North America, Austin, TX, USA Prosthetic Solutions for Active Amputees Andreas Kannenberg, MD, PhD Executive Medical Director North America, Austin, TX, USA Technology is progressing faster than ever before Phone and audio 25 years

More information

New product. Pure Sport.

New product. Pure Sport. New product Pure Sport. Simply run. For jogging or sprinting breathe the fresh air deeply, let your thoughts run free, be active. Nothing is better for clearing your head and just getting away from it

More information

Increasing ankle push-off work with a powered prosthesis does not necessarily reduce metabolic rate for transtibial amputees

Increasing ankle push-off work with a powered prosthesis does not necessarily reduce metabolic rate for transtibial amputees Supplementary Materials Increasing ankle push-off work with a powered prosthesis does not necessarily reduce metabolic rate for transtibial amputees Roberto E. Quesada, Joshua M. Caputo,, and Steven H.

More information

A Bio-inspired Behavior Based Bipedal Locomotion Control B4LC Method for Bipedal Upslope Walking

A Bio-inspired Behavior Based Bipedal Locomotion Control B4LC Method for Bipedal Upslope Walking 1 A Bio-inspired Behavior Based Bipedal Locomotion Control B4LC Method for Bipedal Upslope Walking JIE ZHAO, QI LIU, STEFFEN SCHUETZ, and KARSTEN BERNS Robotics Research Lab, University of Kaiserslautern,

More information

HRC adjustable pneumatic swing-phase control knee

HRC adjustable pneumatic swing-phase control knee HRC adjustable pneumatic swing-phase control knee S. NAKAMURA and S. SAWAMURA Hyogo Rehabilitation Centre, Kobe, Japan Abstract Since 1972 the Hyogo Rehabilitation Centre has been developing a variable-resistance-type

More information

Aeris Performance 2. Product Manual

Aeris Performance 2. Product Manual Aeris Performance 2 Product Manual Instructions The Aeris Performance 2 is designed to be maintenance free. The foot is water resistant; however, if the foot is submerged in water, the foot and foot shell

More information

From early rehab to full recovery RHEO KNEE XC. go anywhere

From early rehab to full recovery RHEO KNEE XC. go anywhere From early rehab to full recovery RHEO KNEE XC go anywhere FROM EARLY REHAB TO FULL RECOVERY, GO ANYWHERE The capabilities that make RHEO KNEE XC dynamic for work and home also make it safe and effective

More information

An investigation of kinematic and kinetic variables for the description of prosthetic gait using the ENOCH system

An investigation of kinematic and kinetic variables for the description of prosthetic gait using the ENOCH system An investigation of kinematic and kinetic variables for the description of prosthetic gait using the ENOCH system K. OBERG and H. LANSHAMMAR* Amputee Training and Research Unit, University Hospital, Fack,

More information

Kintrol Instructions for Use Product Number: VS4

Kintrol Instructions for Use Product Number: VS4 Kintrol Instructions for Use Product Number: VS4 Introduction The Kintrol foot/ankle combines hydraulics and fiberglass to provide K2 ambulators an exceptionally normal walking gait regardless of surface

More information

Kinterra Instructions for Use Product Number: ROM-00-XXXXX-XX

Kinterra Instructions for Use Product Number: ROM-00-XXXXX-XX Kinterra Instructions for Use Product Number: ROM-00-XXXXX-XX Introduction Patient Selection Assembly Alignment The Kinterra foot/ankle system combines hydraulics and carbon fiber, to provide low to moderate

More information

K2 Foot. Product Manual

K2 Foot. Product Manual K2 Foot Product Manual Instructions The K2 is designed to be maintenance free. The foot is water resistant; however, if the foot is submerged in water, the foot and foot shell should be rinsed with fresh

More information

WalkOn product range. Dynamic Ankle-Foot Orthoses. Information for specialist dealers

WalkOn product range. Dynamic Ankle-Foot Orthoses. Information for specialist dealers WalkOn product range Dynamic Ankle-Foot Orthoses Information for specialist dealers WalkOn Flex WalkOn WalkOn Trimable WalkOn Reaction WalkOn Reaction plus One range Many different applications The WalkOn

More information

Plié 3 Microprocessor Knee

Plié 3 Microprocessor Knee Plié 3 Microprocessor Knee 01 Plié 3 MPK Key Features Plié 3 MPK Key Features Ease of Set Up Using Set Up Wizard in Plie Control Software Advanced & Customisable Stumble Recovery Stumble recovery parameters

More information

Element DS. Product Manual

Element DS. Product Manual Element DS Product Manual Instructions The Element DS is designed to be maintenance free. The foot is water resistant; however, if the foot is submerged in water, the foot and foot shell should be rinsed

More information

ASSESMENT Introduction REPORTS Running Reports Walking Reports Written Report

ASSESMENT Introduction REPORTS Running Reports Walking Reports Written Report ASSESMENT REPORTS Introduction Left panel Avatar Playback Right Panel Patient Gait Parameters Report Tab Click on parameter to view avatar at that point in time 2 Introduction Software will compare gait

More information

REPORT DOCUMENTATION PAGE

REPORT DOCUMENTATION PAGE REPORT DOCUMENTATION PAGE Form Approved OMB NO. 0704-0188 The public reporting burden for this collection of information is estimated to average 1 hour per response, including the time for reviewing instructions,

More information

As a physiotherapist I see many runners in my practice,

As a physiotherapist I see many runners in my practice, When rubber meets road Mark Richardson reveals the story that our running shoes can tell us, and how it can help you avoid running injury at a glance This article: Shows you how to analyse the sole of

More information

ParaGolfer. Get up and play. Information for end users

ParaGolfer. Get up and play. Information for end users ParaGolfer Get up and play Information for end users High Quality and Safety Played in a natural setting, golf is a recreational activity that allows you to spend time with friends and family. But above

More information

Microprocessor Technology in Ankle Prosthetics

Microprocessor Technology in Ankle Prosthetics Microprocessor Technology in Ankle Prosthetics Arizona State University Dr. Thomas Sugar Former Students LTC Joseph Hitt, PhD Dr. Kevin Hollander Dr. Matthew Holgate Dr. Jeffrey Ward Mr. Alex Boehler Mr.

More information

PURPOSE. METHODS Design

PURPOSE. METHODS Design 7 Murrary, M.P.; Sepic, S.B.; Gardner, G.M.; and Mollinger, L.A., "Gait patterns of above-knee amputees using constant-friction knee components," Bull Prosthet Res, 17(2):35-45, 1980. 8 Godfrey, C.M.;

More information

Power Assessment of the Human Ankle during the Stance Phase of Walking for Designing a Safe Active Prosthesis in Below-Knee Amputees

Power Assessment of the Human Ankle during the Stance Phase of Walking for Designing a Safe Active Prosthesis in Below-Knee Amputees Applied and Computational Mathematics 2015; 4(2-1): 7-11 Published online February 27, 2015 (http://www.sciencepublishinggroup.com/j/acm) doi: 10.11648/j.acm.s.2015040201.12 ISSN: 2328-5605 (Print); ISSN:

More information

@ Massachusetts Institute of Technology All rights reserved.

@ Massachusetts Institute of Technology All rights reserved. Variable Damping Controller for a Prosthetic Knee during Swing Extension by Luke Matthewson Mooney Submitted to the Department of Mechanical Engineering ARCHIVES in partial fulfillment of the requirements

More information

PRODUCT MANUAL. patent pending

PRODUCT MANUAL. patent pending PRODUCT MANUAL patent pending WAVE COMFORT FOOT SYSTEM The Wave Comfort Foot System brings an exceptional level of comfort to the low and moderate activity user. The unique tri-spring design elements works

More information

Normal and Abnormal Gait

Normal and Abnormal Gait Normal and Abnormal Gait Adrielle Fry, MD EvergreenHealth, Division of Sport and Spine University of Washington Board Review Course March 6, 2017 What are we going to cover? Definitions and key concepts

More information

The Starting Point. Prosthetic Alignment in the Transtibial Amputee. Outline. COM Motion in the Coronal Plane

The Starting Point. Prosthetic Alignment in the Transtibial Amputee. Outline. COM Motion in the Coronal Plane Prosthetic Alignment in the Transtibial Amputee The Starting Point David C. Morgenroth, MD, Department of Rehabilitation Medicine University of Washington VAPSHCS Outline COM Motion in the Coronal Plane

More information

Design of Variable-Damping Control for Prosthetic Knee based on a Simulated Biped

Design of Variable-Damping Control for Prosthetic Knee based on a Simulated Biped Design of Variable-Damping Control for Prosthetic Knee based on a Simulated Biped Jie Zhao, Karsten Berns, Roberto de Souza Baptista, Antônio Padilha L. Bó Robotics Research Lab, Department of Computer

More information

Aeris Activity. Product Manual

Aeris Activity. Product Manual Aeris Activity Product Manual Instructions The Aeris Activity Foot System has been designed and manufactured for specific patient weights. Failure to follow the weight guidelines and/or overload conditions

More information

Influence of speed on gait parameters and on symmetry in transtibial

Influence of speed on gait parameters and on symmetry in transtibial Prosthetics and Orthotics International, 1996, 20, 153-158 Influence of speed on gait parameters and on symmetry in transtibial amputees E. ISAKOV*, H. BURGER**, J. KRAJNIK**, M. GREGORIC** and C. MARINCEK**

More information

Gait. Kinesiology RHS 341 Lecture 12 Dr. Einas Al-Eisa

Gait. Kinesiology RHS 341 Lecture 12 Dr. Einas Al-Eisa Gait Kinesiology RHS 341 Lecture 12 Dr. Einas Al-Eisa Definitions Locomotion = the act of moving from one place to the other Gait = the manner of walking Definitions Walking = a smooth, highly coordinated,

More information

AllPro Foot. Product Manual

AllPro Foot. Product Manual AllPro Foot Product Manual Instructions The AllPro Foot System has been designed and manufactured for specific patient weights. Failure to follow the weight guidelines and/or overload conditions caused

More information

Otto Bock and Springlite Feet

Otto Bock and Springlite Feet Otto Bock and Springlite Feet Advantage DP2 The Advantage DP2 is Otto Bock s lightest weight dynamic pylon foot system. It is an ultra lightweight foot that offers energy return and dynamic response. It

More information

Using GPOPS-II to optimize sum of squared torques of a double pendulum as a prosthesis leg. Abstract

Using GPOPS-II to optimize sum of squared torques of a double pendulum as a prosthesis leg. Abstract Using GPOPS-II to optimize sum of squared torques of a double pendulum as a prosthesis leg Abstract Milad Zarei MCE 593 Prosthesis Design & Control A two-dimensional, two links pendulum is developed to

More information

Stabilization of a Three-Dimensional Limit Cycle Walking Model through Step-to-Step Ankle Control

Stabilization of a Three-Dimensional Limit Cycle Walking Model through Step-to-Step Ankle Control 2013 IEEE International Conference on Rehabilitation Robotics June 24-26, 2013 Seattle, Washington USA Stabilization of a Three-Dimensional Limit Cycle Walking Model through Step-to-Step Ankle Control

More information

DYNAMIC. Make your move SOLUTIONS. Stable enough for Mike. Dynamic enough for Nuria.

DYNAMIC. Make your move SOLUTIONS. Stable enough for Mike. Dynamic enough for Nuria. DYNAMIC SOLUTIONS Make your move Stable enough for Mike. Dynamic enough for Nuria. ÖSSUR DYNAMIC SOLUTIONS Reassuring stability for Mike empowering dynamics for Nuria Not everyone s priorities are the

More information

KOTARO SASAKI Curriculum Vitae

KOTARO SASAKI Curriculum Vitae KOTARO SASAKI Curriculum Vitae Department of Mechanical & Biomedical Engineering Boise State University 1910 University Dr. Boise ID 83725-2075 Phone: (208) 426-4027 Email: kosasaki@boisestate.edu EDUCATION

More information

Amandi Rhett, OPS III December 2, 2016

Amandi Rhett, OPS III December 2, 2016 A COMPARISON OF AN ABOVE THE KNEE AMPUTEE SPRINTER WHO USES A STRAIGHT PYLON NON-ARTICULATING RUNNING PROSTHESIS AND AN ARTICULATING KNEE RUNNING PROSTHESIS TO SPRINT A CASE STUDY Amandi Rhett, OPS III

More information

Control of a Powered Ankle Foot Prosthesis Based on a Neuromuscular Model

Control of a Powered Ankle Foot Prosthesis Based on a Neuromuscular Model Control of a Powered Ankle Foot Prosthesis Based on a Neuromuscular Model The MIT Faculty has made this article openly available. Please share how this access benefits you. Your story matters. Citation

More information

Wave Comfort 2. Product Manual

Wave Comfort 2. Product Manual Wave Comfort 2 Product Manual Instructions The Wave Comfort 2 is designed to be maintenance free. The foot is water resistant; however, if the foot is submerged in water, the foot and foot shell should

More information

Dynamically stepping over large obstacle utilizing PSO optimization in the B4LC system

Dynamically stepping over large obstacle utilizing PSO optimization in the B4LC system 1 Dynamically stepping over large obstacle utilizing PSO optimization in the B4LC system QI LIU, JIE ZHAO, KARSTEN BERNS Robotics Research Lab, University of Kaiserslautern, Kaiserslautern, 67655, Germany

More information

Foot Biomechanics Getting Back to the Base

Foot Biomechanics Getting Back to the Base Foot Biomechanics Getting Back to the Base Christopher J. Mehallo, D.O. Rothman Institute Orthopaedics Objectives Understand basic foot biomechanics during walking and running Understand common sports

More information

AllPro Foot. Posterior Mount Product Manual

AllPro Foot. Posterior Mount Product Manual AllPro Foot Posterior Mount Product Manual Instructions The AllPro PM foot system has been designed and manufactured for specific patient weights. Failure to follow the weight guidelines and/or overload

More information

G-EOL. Discover the simplicity of gait therapy intended for daily use

G-EOL. Discover the simplicity of gait therapy intended for daily use G-EOL Discover the simplicity of gait therapy intended for daily use Reha Technology a passion for robotic-assisted gait therapy For over 10 years, Reha Technology has been successfully developing innovative,

More information

premise that interdependent body systems (e.g. musculoskeletal, motor, sensory, and cognitive

premise that interdependent body systems (e.g. musculoskeletal, motor, sensory, and cognitive APPENDIX 2 Motor Control Intervention Protocol The dynamic systems approach underlying motor control intervention is based on the premise that interdependent body systems (e.g. musculoskeletal, motor,

More information

Walking Simulator Mechanism

Walking Simulator Mechanism The Downtown Review Volume 2 Issue 2 Article 4 2015 Walking Simulator Mechanism Titus Lungu Cleveland State University Igor Tachynskyy Cleveland State University Omri Tayyara Cleveland State University

More information

A MATHEMATICAL MODEL TO DETERMINE THE TORQUE FOR A PROSTHETIC LEG-LAGRANGIAN EQUATION

A MATHEMATICAL MODEL TO DETERMINE THE TORQUE FOR A PROSTHETIC LEG-LAGRANGIAN EQUATION Volume 6 No. 5 7, 5-56 ISSN: 3-88 (printed version); ISSN: 34-3395 (on-line version) url: http://www.ijpam.eu A MATHEMATICAL MODEL TO DETERMINE THE TORQUE FOR A PROSTHETIC LEG-LAGRANGIAN EQUATION ijpam.eu

More information

Chapter 1 - Injury overview Chapter 2 - Fit for Running Assessment Chapter 3 - Soft Tissue Mobilization... 21

Chapter 1 - Injury overview Chapter 2 - Fit for Running Assessment Chapter 3 - Soft Tissue Mobilization... 21 Table of Contents Introduction Chapter 1 - Injury overview... 6 Chapter 2 - Fit for Running Assessment... 13 Chapter 3 - Soft Tissue Mobilization... 21 Chapter 4 - Dynamic Warm-up... 28 Chapter 5 - Strengthening...

More information

Finite-State Control of Powered Below-Knee Prosthesis with Ankle and Toe

Finite-State Control of Powered Below-Knee Prosthesis with Ankle and Toe Finite-State Control of Powered Below-Knee Prosthesis with Ankle and Toe Kebin Yuan, Jinying Zhu, Qining Wang, Long Wang Intelligent Control Laboratory, College of Engineering, Peking University, Beijing

More information

Running Injuries in Adolescents Jeffrey Shilt, M.D. Part 1 Page 1

Running Injuries in Adolescents Jeffrey Shilt, M.D. Part 1 Page 1 Running Injuries in Adolescents Jeffrey Shilt, M.D. Chief Surgical Officer, The Woodlands, Texas Children's Hospital Associate Professor, Orthopedic and Scoliosis Surgery, Baylor College of Medicine Part

More information

INTERACTION OF STEP LENGTH AND STEP RATE DURING SPRINT RUNNING

INTERACTION OF STEP LENGTH AND STEP RATE DURING SPRINT RUNNING INTERACTION OF STEP LENGTH AND STEP RATE DURING SPRINT RUNNING Joseph P. Hunter 1, Robert N. Marshall 1,, and Peter J. McNair 3 1 Department of Sport and Exercise Science, The University of Auckland, Auckland,

More information

Dynamic/Static Foot. Tissues. Static Foot. Dynamic Foot

Dynamic/Static Foot. Tissues. Static Foot. Dynamic Foot Dynamic/Static Tissues Static Plantar fascia biomechanical windlass mechanism intrinsic muscles stabilize metatarsophalangeal (MP) toe joints Weight on whole foot - MP toe joints straight Plantar fascia

More information

CHAPTER IV FINITE ELEMENT ANALYSIS OF THE KNEE JOINT WITHOUT A MEDICAL IMPLANT

CHAPTER IV FINITE ELEMENT ANALYSIS OF THE KNEE JOINT WITHOUT A MEDICAL IMPLANT 39 CHAPTER IV FINITE ELEMENT ANALYSIS OF THE KNEE JOINT WITHOUT A MEDICAL IMPLANT 4.1 Modeling in Biomechanics The human body, apart of all its other functions is a mechanical mechanism and a structure,

More information

Gait analysis for the development of the biped robot foot structure

Gait analysis for the development of the biped robot foot structure Preprints of the 9th World Congress The International Federation of Automatic Control Cape Town, South Africa. August 4-9, 4 Gait analysis for the development of the biped robot foot structure Yusuke OGAWA

More information

Niagara Foot. Dynamic Performance at Every Step

Niagara Foot. Dynamic Performance at Every Step Niagara Foot Dynamic Performance at Every Step 1 Table of Contents Concept 3 Biomechanics 3 Tech Specs.4 Static/Bench Alignment..5 Dynamic Alignment..6 Niagara Foot Modifications 7 Assembly Instructions..10

More information

Below-knee amputation: a comparison of the effect of the SACH foot and single axis foot on electromyographic patterns during locomotion

Below-knee amputation: a comparison of the effect of the SACH foot and single axis foot on electromyographic patterns during locomotion Prosthetics and Orthotics International, 1986, 10, 15-22 Below-knee amputation: a comparison of the effect of the SACH foot and single axis foot on electromyographic patterns during locomotion E. G. CULHAM,

More information

Customized rocker sole constructions

Customized rocker sole constructions Customized rocker sole constructions German guidelines to improve results in daily practice Stief, Thomas Registered Association for the Encouragement of Research and Education Management in Orthopedic

More information

Controlling Knee Swing Initiation and Ankle Plantarflexion With an Active Prosthesis on Level and Inclined Surfaces at Variable Walking Speeds

Controlling Knee Swing Initiation and Ankle Plantarflexion With an Active Prosthesis on Level and Inclined Surfaces at Variable Walking Speeds REHABILITATION DEVICES AND SYSTEMS Received 17 October 2013; revised 6 February 2014; accepted 20 July 2014. Date of publication 25 July 2014; date of current version 12 August 2014. Digital Object Identifier

More information

The Mechanics of Modern BREASTSTROKE Swimming Dr Ralph Richards

The Mechanics of Modern BREASTSTROKE Swimming Dr Ralph Richards The Mechanics of Modern BREASTSTROKE Swimming Dr Ralph Richards Breaststroke is the least efficient of the four competition strokes because a large amount of water resistance is created due to body position

More information

Effects of Mass and Momentum of Inertia Alternation on Individual Muscle Forces During Swing Phase of Transtibial Amputee Gait

Effects of Mass and Momentum of Inertia Alternation on Individual Muscle Forces During Swing Phase of Transtibial Amputee Gait Kobe J. Med. Sci., Vol. 56, No. 3, pp. E92-E97, 21 Effects of Mass and Momentum of Inertia Alternation on Individual Muscle Forces During Swing Phase of Transtibial Amputee Gait YAGHOUB DABIRI 1, SIAMAK

More information

Conceptual Design of an Energy Efficient Transfemoral Prosthesis

Conceptual Design of an Energy Efficient Transfemoral Prosthesis The 2010 IEEE/RSJ International Conference on Intelligent Robots and Systems October 18-22, 2010, Taipei, Taiwan Conceptual Design of an Energy Efficient Transfemoral Prosthesis R. Unal, R. Carloni, E.E.G.

More information

Barefoot Running. Ed Mulligan, PT, DPT, OCS, SCS, ATC. Clinical Orthopedic Rehabilitation Education

Barefoot Running. Ed Mulligan, PT, DPT, OCS, SCS, ATC. Clinical Orthopedic Rehabilitation Education Barefoot Running Ed Mulligan, PT, DPT, OCS, SCS, ATC Clinical Orthopedic Rehabilitation Education Not a new concept Nov 1958 1984 Olympics Interesting Trivia Abebe Bilika won the 1960 Olympic marathon

More information

The Influence of High Heeled Shoes on Kinematics, Kinetics, and Muscle EMG of Normal Female Gait

The Influence of High Heeled Shoes on Kinematics, Kinetics, and Muscle EMG of Normal Female Gait JOURNAL OF APPLIED BIOMECHANICS, 2000, 16, 309-319 2000 by Human Kinetics Publishers, Inc. The Influence of High Heeled Shoes on Kinematics, Kinetics, and Muscle EMG of Normal Female Gait Darren J. Stefanyshyn,

More information

Evaluation of gait symmetry in poliomyelitis subjects : Comparison of a

Evaluation of gait symmetry in poliomyelitis subjects : Comparison of a Evaluation of gait symmetry in poliomyelitis subjects : Comparison of a conventional knee ankle foot orthosis (KAFO) and a new powered KAFO. Arazpour, M, Ahmadi, F, Bahramizadeh, M, Samadiam, M, Mousavi,

More information

Krabat Jockey. Technical data. Awards. Product variations

Krabat Jockey. Technical data. Awards. Product variations Krabat Jockey Technical data A A I I B B J J C C D D G G E E F F H H SITTING Krabat Jockey Krabat Jockey is an active children s chair from Krabat. The child is seated on a saddle with his/her legs apart.

More information

EXPERIMENTAL STUDY OF EXOSKELETON FOR ANKLE AND KNEE JOINT

EXPERIMENTAL STUDY OF EXOSKELETON FOR ANKLE AND KNEE JOINT EXPERIMENTAL STUDY OF EXOSKELETON FOR ANKLE AND KNEE JOINT PROJECT REFERENCE NO. : 37S0925 COLLEGE : NEW HORIZON COLLEGE OF ENGINEERING, BANGALORE BRANCH : MECHANICAL ENGINEERING GUIDES : DR GANESHA PRASAD

More information

Ideal Heel Promotes proper alignment and reduces lever arms

Ideal Heel Promotes proper alignment and reduces lever arms IDEAL Technologies Ideal Heel Promotes proper alignment and reduces lever arms The Ideal Heel is an innovation that shifts the ground contact point forward. The runner lands with more ground clearance

More information

Diabetes and Orthoses. Rob Bradbury Talar Made

Diabetes and Orthoses. Rob Bradbury Talar Made Diabetes and Orthoses Rob Bradbury Talar Made Diabetes High prevalence disease 4-6% in UK (over 2.5 mill diagnosed and a further 0.5 ) 6+% in USA 40% in some parts of Middle East (may be higher in Indian

More information

Gait Analyser. Description of Walking Performance

Gait Analyser. Description of Walking Performance Gait Analyser Description of Walking Performance This brochure will help you to understand clearly the parameters described in the report of the Gait Analyser, provide you with tips to implement the walking

More information

Propulsion Ankle Prosthetic

Propulsion Ankle Prosthetic Propulsion Ankle Prosthetic Awab Umar Khan 1 [Brad Stout 2 ] Abstract Muscle atrophy is a major problem for the less fortunate amputees. Mercer on Mission is a program that goes annually to Vietnam to

More information

-Elastic strain energy (duty factor decreases at higher speeds). Higher forces act on feet. More tendon stretch. More energy stored in tendon.

-Elastic strain energy (duty factor decreases at higher speeds). Higher forces act on feet. More tendon stretch. More energy stored in tendon. As velocity increases ( ) (i.e. increasing Froude number v 2 / gl) the component of the energy cost of transport associated with: -Internal kinetic energy (limbs accelerated to higher angular velocity).

More information

USA Track & Field Heptathlon Summit- November

USA Track & Field Heptathlon Summit- November USA Track & Field Heptathlon Summit- November 1994 1 I. Technical considerations in the sprint hurdles Practical Biomechanics For the 100m Hurdles By Gary Winckler University of Illinois A. General flow

More information

The new C-Brace. Physiotherapy training guideline. Information for therapists and technicians

The new C-Brace. Physiotherapy training guideline. Information for therapists and technicians The new C-Brace Physiotherapy training guideline Information for therapists and technicians Table of contents The C-Brace restores a feeling of safety so I can walk on uneven terrain again. Introduction

More information

The technique of reciprocal walking using the hip guidance orthosis (hgo) with crutches

The technique of reciprocal walking using the hip guidance orthosis (hgo) with crutches The technique of reciprocal walking using the hip guidance orthosis (hgo) with crutches P. B. BUTLER, R. E. MAJOR and J. H. PATRICK Orthotic Research and Locomotor Assessment Unit, The Robert Jones and

More information

Define terms and compute basic physics problems related to sprinting

Define terms and compute basic physics problems related to sprinting LINEAR SPEED AN INTRODUCTION TO ACCELERATION LEARNING OBJECTIVES Define terms and compute basic physics problems related to sprinting Identify and explain how specific kinematic and kinetic elements relate

More information

The effect of footwear mass on the gait patterns of unilateral below-knee amputees

The effect of footwear mass on the gait patterns of unilateral below-knee amputees Prosthetics and Orthotics International, 1989,13, 140-144 The effect of footwear mass on the gait patterns of unilateral below-knee amputees J. M. DONN, D. PORTER and V. C. ROBERTS Department of Medical

More information

Design and Evaluation of a Variable Resistance Orthotic Knee Joint

Design and Evaluation of a Variable Resistance Orthotic Knee Joint Design and Evaluation of a Variable Resistance Orthotic Knee Joint Andrew Herbert-Copley Thesis submitted to the faculty of graduate and postdoctoral studies in partial fulfillment of the requirements

More information

Center of Mass Acceleration as a Surrogate for Force Production After Spinal Cord Injury Effects of Inclined Treadmill Walking

Center of Mass Acceleration as a Surrogate for Force Production After Spinal Cord Injury Effects of Inclined Treadmill Walking Center of Mass Acceleration as a Surrogate for Force Production After Spinal Cord Injury Effects of Inclined Treadmill Walking Mark G. Bowden, PhD, PT Research Health Scientist, Ralph H. Johnson VA Medical

More information

NeuroOrthopaedics lower extremity

NeuroOrthopaedics lower extremity NeuroOrthopaedics lower extremity Medical devices for drop foot Information for technicians and therapists NeuroOrthopaedics lower extremity Ottobock 1 The right device for every user Around the world,

More information

Instructions for Use PROPRIO FOOT

Instructions for Use PROPRIO FOOT Instructions for Use PROPRIO FOOT 3 SAFETY PRECAUTIONS 4 INTRODUCTION 4 TECHNICAL SPECIFICATIONS 5 BASIC OPERATION 6 FUNCTIONS 7 MAINTENANCE 10 WARRANTY 10 CATEGORY SELECTION CHART 10 ELECTROMAGNETIC COMPATIBILITY

More information

Spring Locomotion Concepts. Roland Siegwart, Margarita Chli, Martin Rufli. ASL Autonomous Systems Lab. Autonomous Mobile Robots

Spring Locomotion Concepts. Roland Siegwart, Margarita Chli, Martin Rufli. ASL Autonomous Systems Lab. Autonomous Mobile Robots Spring 2016 Locomotion Concepts Locomotion Concepts 01.03.2016 1 Locomotion Concepts: Principles Found in Nature ASL Autonomous Systems Lab On ground Locomotion Concepts 01.03.2016 2 Locomotion Concepts

More information