FLOWMETER. FM-PF Series

Similar documents
Series SFD. Clean Air Filter. Variations. Made to Order. Type. Cartridge (replaceable element) Disposable (non-replaceable element) Up to 100

Needle valve. Contents. User s Manual. (1) Be sure to read the following warranty clauses of our product 1. (2) General operating instructions 2

Dual Solenoid Gas Valve Installation

Pilot Check Valve: Metal Body Type

Automatic Non-freeze Valve NF6

E8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm)

GM-7000 Series CE Approved Gas Control Valve

36H SERIES Combination Gas Valve

KOBOLD KSM FLOWMETER. User Instructions

Wafer Check Valve. Contents. User s Manual. (1) Be sure to read the following description of our product warranty 1

BGC258 Series BASOTROL Gas Valve

APCO ARV CLEAN WATER AIR RELEASE VALVES. Model 50A

Operation Manual Air Saver Unit ASV5000 Series

G92 Series BASOTROL Automatic Pilot Gas Valve

Clean Regulator/Fluororesin Type

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO

Pre-filter for Brushless Blower Instruction Manual

INSTALLATION & MAINTENANCE INSTRUCTIONS

Installation, operating and maintenance Instructions for Seemag bypass level indicator

OPERATION MANUAL NTF-15

Electro-Pneumatic Converter YT-940 SERIES

OPERATING MANUAL CHEMTRAC 840M MANUAL RETRACTABLE PROCESS HOLDER

BGA158 Series CE Approved Class B Shutoff Gas Valve

Air Saving Valve. Pressure Valve Flow Valve

FLOWMETER MANUAL MODEL V AND V D

OPERATING AND MAINTENANCE MANUAL

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

Mini-Pro CO2 Sensor User s Manual - ANALOG MODEL -

BGA158, BGA171 and BGA110 Series Shutoff Gas Valve

BGA158 Series CE Approved Class A Shutoff Gas Valve

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

VAPOMATIC ANESTHETIC VAPORIZER

GM Series Dual-Block Multi-Function Gas Control Valves

Lab Cock. Contents. User s Manual (1) Be sure to read the following warranty clauses of our product 1. (2) General operating instructions 2

36E03 and 36E38 DSI and HSI Step Opening Combination Gas Valve INSTALLATION INSTRUCTIONS

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

MODEL 154XST INSTALLATION AND SERVICE INSTRUCTIONS FOR MODEL 154XST STROBE LIGHT FOR USE IN HARSH ENVIRONMENTS/ HAZARDOUS LOCATIONS

SPECIFICATIONS ATTENTION

Operating instructions for variable area flow meter with needle valve. Model: UVR/UTR

G96 Series BASOTROL Dual Operator Valve

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

LRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator.

Glass tube flowmeters Series 2000

AIR-OPERATED DOUBLE DIAPHRAGM PUMP USER S MANUAL

! Warning, refer to accompanying documents.

Operator: Save these instructions for future use!

OPERATION MANUAL NTF-60 Plus

DC5A. Cyclone Separator Trap for Air. Copyright 2015 by TLV Co., Ltd. All rights reserved ISO 9001/ ISO MA-03 (DC5A) 19 June 2015

Measurement of Low GAS & Liquid Flows

Air Saving Valve. Series ASQ. Series ASR. Pressure Valve. Flow valve TMH ASD AS AS-FG AS-FP AS-FM ASP ASN AQ ASV AK VCHC ASS. r r AS-FE KE 10 0.

36E DSI and HSI Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS

FPD20 Series. Gear wheel flow sensor

DPC-30 DPC-100. Reference Manual

PULSAR 5000 SERIES OPERATING & INSTALLATION INSTRUCTIONS SERIES 5000 PLEASE READ CAREFULLY BEFORE INSTALLING

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

Air Saving Valve reduction in 40% air consumption 40% air consumption Air consumption reduction ratio (%) Flow valve Flow valv

Compact Ball Valves ASAHI AV VALVES. Contents. User s Manual. (Page) (1) Be sure to read the following warranty clauses of our product 1

New Product. Air Consumption 70% Down. Precision Regulator Air Saving Type. RPE Series PRECISION REGULATOR RPE SERIES CC-1072A

High Pressure Inlet Kits for CONCOA BlendMites and BlendMasters

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

Operator: Save these instructions for future use!

Types 749B and R130 Changeover Manifolds

100C Air Compressor Kit

Columbus Instruments

Vacuum Regulator. IRV10/20 Series. Weight reduced by. RoHS ARJ ARX AMR ARM ARP IR -A IR IRV VEX SRH SRP SRF ITV

OWNER S TECHNICAL MANUAL

Maximum 0.85 MPa pressure setting Long-life, high flow perfect for balancer applications

Safety instructions and operating manual

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

U S E R M A N U A L CAUTION. SAVE THESE INSTRUCTIONS Federal (USA) law restricts this device to sale by or on the order of a physician.

No.IL02-OM00011-A PRODUCT NAME LOCK UP VALVE. MODEL/ Series IL201 IL211

Installation and Operation Manual

ACRYLIC FLOW METERS 0-30, 0-70 & LPM

Installation, Operation, and Maintenance Manual

36E DSI, HSI & Proven Pilot Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS

English. Introduction. Safety Instructions. All Products. Inspection and Maintenance Schedules. Parts Ordering. Specifications WARNING WARNING

INSTRUCTIONS FOR SERIES 50 & 50K FLOWMETERS

1 DRIVE INDUSTRIAL IMPACT WRENCH

200 PSI COMPRESSORS - MODEL NUMBERS

Instruction Manual 742 5/1/2009. Eclipse Ratio Regulators ES Series Version 1

UL Listed GM-20/25 and GM-40/45 Series Dual-block Multi-function Gas Control Valves

Mooney * Noise Controller Installation, Operation, and Maintenance Manual

Purgemaster Series 10A6100 SNAP-IN. Instruction Bulletin Replaceable Parts List. D184B003U35 Rev. 01 /

DK48 - DK800. Quick Start. Variable area flowmeter

200 PSI HIGH-FLOW AIR SOURCE KIT

200 PSI FAST-FILL AIR SOURCE KIT

INSTRUCTION MANUAL Pressure Relief Device LPT

USER MANUAL. MACMAG magnetic separator MHK MHF

Exercise 5-2. Bubblers EXERCISE OBJECTIVE DISCUSSION OUTLINE. Bubblers DISCUSSION. Learn to measure the level in a vessel using a bubbler.

Atmospheric relief valve type 1100 Installation and maintenance instructions

D10S/D20S Wall/Post Mount Inflator Quick Start Manual

ATS430 turbidity sensor Retractable insertion assembly

L 100. Bubble-Tube Level System. Installation, Operation and Maintenance Instructions

USER MANUAL. 1. Principle of operation. 2. Delivery condition. SPRING-LOADED SAFETY VALVES zarmak. Edition: 07/2016 Date: V (ex.

OFFICINE OROBICHE S.p.A. 1/9

Type 3709 Pneumatic Lock-up Valve. Translation of original instructions. Mounting and Operating Instructions EB 8391 EN

/ Air Line Kit AL - M1202. / OPERATION MANUAL P1 - P9 / English P11 - P19 OM-K0651

GA24 Technical Datasheet

GILMONT ACCUCAL FLOWMETERS

Transcription:

Integral mold flowmeter available for ultra-pure water/chemicals Caution FLOWMETER Instruction manual for FM-PF Series (Excel type) Before use, please read this Instruction manual with caution for your safety operation. Please always keep this Instruction Manual at hand for your quick reference when necessary. 37-R06

Safety precaution We highly appreciate your purchasing our products of flowmeter modeled FM-PF Series (Excel type). Please read thoroughly this Instruction Manual ensuring the following descriptions in order to properly use and for your safety operation, and also for the purpose of prevention from disaster that might be caused. The Safety precaution intends to prevent the users or persons in charge from injury or to take precaution against preventing damage to the property which may happen so that it is required to read through with a better understanding. Warning Caution This is the safety alert symbol which indicates the potential for the death or serious injury which might be caused. This is the safety-alert symbol which indicates the potential for injury or material damage which might be caused. Table of Contents 1. Features 3 2. Type selection 3 3. Specifications 4 4. A table of flowrates and standard dimensions 5 5. Structural drawing for PF200/300 types with photosensor 6 6. Structural drawing for PF400/500 types with magnetic sensors 8 7. Materials 10 8. A table of sensors classified by sensors 10 9. Assembling and disassembling procedures 10 10. Installation procedures to the machinery and equipment 12 11. Confirmation of flowrates 13 12. Standard specifications for the magnetic sensor 13 13. Standard specifications for the photosensor 13 14. Other instructions 13 15. Precautions when the trouble occurred 14 16. Where to contact 14

1. Features FM-PF FM-PF Series (Excel type) is a flowmeter which has been designed for the use in pure water (and ultra-pure water) requisite for the semiconductor industry and excellent in leakage resistance and the fluid to be measured can be measured as it is left clean, because it is made from an integral moulding. And as not alone the appearance but all the body is made from fluorocarbon resin, it can be securely used in the corrosive atmosphere and even under the harsh conditions. Due to the employment of PFA integral moulding (made from all Teflon), there is no fear of eakage, and the cutting area has been reduced to the utmost. Available for the strong acid and alkali chemicals, and also for the flow measurement of highly purified gases. If setting the sensor head to the desired values of flow, it can produce an abnormal signal of flow. 2. Type selection Std Shape Shape Name of fluid Units of flow Max flow Pipe size Opt. For specif. item FM-PF 200-0 3 1 -B 2-21 -PD1 For instance of entry / Description PF Perfluoro packing PD 1 With photosensor formed dark-on at 24VDC10%7 PL 1 With photosensor formed light-on at 24VDC10%7 PD 2 With photosensor formed dark-on at 12VDC10%7 PL 2 With photosensor formed light-on at 12VDC10%7 W Cap to be welded Rc3/8 400 1/2 3/4 500 TV1/4 200 3/8 300 1/2 400 3/4 500 It indicates max flowrate. 6 ml/min L/min For specif. unit 5 Pure water For specif. fluid 4 Shape Shape With no needle valve 0 With no sensor With needle valve at upper side 1 With contact A of magnetic side switch 2 For specif. shape 1 2 With contact B of magnetic side switch 2 3 With contact A of magnetic rear switch Maximum flowrates 4 With contact B of magnetic rear switch Up to 2 L/min Up to 3.5 L/min Up to 15 L/min 9 For specif. shape 3 Up to 50 L/min 1, 3, 4, and 5For specif. items specify them at the end of this Type Selection in order. 2 For installation of magnetic switch, standard installation is on right as one faces. 6 See a table of flowrates shown below 7 When selecting photosensor, select the item 9 in Shape 2, and specify it at the Optional items.

3. Specifications Flow accuracy Max operating pressure Operating fluid temperature Ambient temperature FS5% 0.35Mpa(G) Max 40 0 40 (Non condensing) Magnetic switch Photosensor Contact form Contact A Dark-on Contact B Light-on Contact capacity 0 24VDC 12VDC or 24VDC Max 0.2A Max 80mA Cord length 50 cm 2 m Grade (Compliant with our standards) Cleanliness factors Ultrasonic cleaning by alcohol Assembled in clean room Nitrogen gas charging packing Warning Use the FM-PF Series Excel typed fowmeter within the rated pressure. Use the FM-PF Series Excel typed flowmeter within the range of the operating heat resistance. If exceeded the rated pressure and temperature, it may cause damage to the tapered tube. Use the FM-PF Series Excel typed flowmeter filled fully with fluid inside the meter body. Mixing of the bubbles into the inside of the flowmeter can cause it to read inaccurately and/or malfunction.

4. A table of flowrates and standard dimensions L l1 l2 l3 l4 l5 l6 Ho H B b1 b2 b3 D Do Rc xl Remarks ml/min 2 20 200 5 50 10 100 20 200 20 300 50 500 106 (110) 80 60 100 10 26 32 20 26 30 17 6.35 X 4.35 X 42 Magnetic sensor impossible to use L/min 0.1 1 300 400 500 0.2 2 0.1 1 0.2 1.5 0.2 2 0.2 2.5 0.2 3 0.4 3.5 0.2 3 0.4 5 1 10 2 15 2 15 2 20 3 30 4 40 4 50 134 (138) 169 (165) 206 (198) 100 76 124 12 80 32 37 26 28 33 15 21 115 80 90 75 12.5 63 57 51 42 28 30 43 29 29 150 100 112 90 19 80 65 57 52 30 32 52 39 37 Rc 3/8 Rc 1/2 3/4 9.53 X 6.33 X 47 12.7 x 9.5 x 100 19 x 15.8 x 100 Magnetic sensor impossible to use Mg sensor impossible to use Magnetic sensor impossible to use Flowrates shown above are ones equivalent to water at 20.

5. Structural drawing PF200/300 types with photosensor l Brown Blue Black Brown Blue Through holes Through holes

For panel cut-out (Panel embedded type) For panel cut-out for the type with rear magnetic switch (Front panel type) For panel cut-out for the type with Photosensor (Front panel type) PF200/300 PF300 PF200 PF300 Through holes Through holes Through holes If the type is without needle valve, there is no need to provide withdo.

6. Structural drawing PF400/500 types with rear magnetic switch Brown Blue l

For panel cut-out (Panel embedded type) PF400/500 For panel cut-out for the type with rear magnetic switch (Front panel type) PF400/500 For panel cut-out for the type with Photosensor (Front panel type) PF400/500 If the type is without needle valve, there is no need to provide withdo.

7. Materials Item No. FPM (PF also available) For O-ring used for PF200 type, PF is a standard. 8. A table of sensors classified by sensor Photosensor Magnetic sensor PF200 PF300 PF400 PF500 Caution 9. Assembling and disassembling procedures The warranty period is in principle for one year after delivered. If disassembled by your customer during that time for maintaining the flowmeter, it should be noted that it shall not be covered by warranty. There are some products which cannot be disassembled according to the product specifications. 1. In the case that the type where both caps located at the upper and lower part of the body are manufactured in accordance with the weld specification. 2. In the case that the type is with needle valve, but with no sensor specification ( See the list below ). It is possible to disassemble the needle valve section and some kinds of plates such as scale plate, side plate and back plate, etc..

Caution Specifications where the inside of the flowmeter cannot be disassembled. Types Specifications Max flowrates 20mL/min 50mL/min 100mL/min 500mL/min 1.5L/min 2.0L/min 10L/min 15L/min It is usual to take out the float through the cap located at lower part of the meter body, if it is the specification with needle valve, but the specifications stated above has a structure which cannot take out the float due to the measurement of the meter body and the float. The flowrates shown above are ones that are water equivalent. Caution The assembling and disassembling for maintaining the flowmeter should be done according to the following procedures. 1. Disassembling of the needle valve section (For specification with needle valve only) Turn the needle valve counterclockwise to fully open. Turn the gland counterclockwise to loosen. All th dl l t t t l k i f th t 2. Disassembling of the various kinds of plates Unscrew the screws tightened with the countersunk screws(m3) in four places of such plate as the front plate( for PF400 and PF500 types only ), scale plate, side plate and back plate in sequential order. 3. Assembling and disassembling of the main body Allow the cap located at the inlet side ( lower part)to turn counterclockwise and remove it, and then take out an O-ring. Take out the float. Allow the cap located at the outlet side (upper part) to turn counterclockwise and remove it, then take out an O-ring. Assembling should be done in the reverse order from the disassembling. A great care should be taken for the excessive tightening for the tightening portions.

Caution 10. Installation procedures to the machinery and equipment 1. Handle with caution and unpack and install it in a place where is as clean as possible, because it has been packed in the clean room after cleaning. 2. Upon receipt of the product you put an order, check for any damage which may have occurred during shipment, prior to installing. Movement of float, contact forms and flow direction, etc.. 3. For installing to the machinery and equipment, do it with reference to the Illustration 1. Be sure to use the given hole to mount the main body. PF200 To use four holes(3.5) located at the corner viewing from front PF300 To use four holes(4.5) located at the corner viewing from front PF400/500 To use the two mounting taps located at the back (M5 and 5 long) For panel imbedded type, remove the front panel to use their same holes in four places. 4. As it is a floating type of flowmeter, it is important that the meter body be piped absolutely vertical so as smoothly to move the movable part and also not to apply stress due to the installation. 5. In making up pipe, do not enter the sealing or any other foreign materials into the inside of the meter. Dirt and foreign matters inside the flowmeter can cause it to indicate inaccurately. 6. Use the flowmeter in a place where is less mechanical vibration. If vibrated, it may cause disconnection of cable and particle occurrence(dirt, etc.). 7. After completed installing to the equipment, the valve should be opened as gradually as possible when starting operating the flowmeter. If the valve is so quickly opened, it may fail to operate properly due to the turbulent flow. 8. The tube fittings (joints) should be connected according to the instruction manual of their own. 9. Never use the flowmeter as immersed in fluid.

11. Confirmation of flowrate How to read the flowrate Take reading at eye level so as to be horizontal to the top of the flat surface of the float 12. Standard specifications for the magnetic sensor Contact capacity: 0-24VDC Max 0.2A 4.8W (Compliant with UL standard) As a non-standard specification 100VAC/DC 0.25A 20W cos and 200VAC/DC 0.1A 20W cos are also available upon request, but not compliant with UL standard. Contact resistance: For one minute at 500VDC Withstand voltage: 1200V/AC /sec Life span of contact switching: More than one million times, provided that it is at pure resistant load. Contact forms: Contact A (To be turned on, when flowrate increases more than setting value) Contact B( To be turned on, when flowrate decrease less than setting value) Setting value variable Contact is self-holding type. Accuracy: Contact accuracy: Within 10% 13. Standard specifications for photosensor Operating power supply: 12-24VDC within10% Power consumption: Less than 15mA Output mode: NPN open collector Rating: Sink power supply: 80mA (30VDC) at max Operation mode: Dark-on Variable setting value Warnin 14. Other instructions If exceeded the rating of the electrical contact, it may cause damage. Wiring should be done after making sure that power have been turned off. If the connecting wires coming from the flowmeter are wired together with a strong power line such as power supply line, power line and high voltage cable, noises may transfer to the signal lines, and may result in malfunction. In no case shall the flowmeter be used in environment where explosive gas exists except it is constructed in accordance with the specifications for the intrinsic safety explosion-proof type photosensor. Do not remodel the flowmeter body. Do not put the flowmeter body in a place where is unstable. It may cause damage and injury resultantly. Although the flowmeter is light in weight, support the pipe so as not to kink and sag, and securely fix so as not to exert stress or forces upon the Teflon flowmeter.

Caution 15. Precautions when trouble happened (Flowmeter body) If leakage from the flowmeter body or the connecting section(tube fitting, etc.) occurred, immediately stop operating the line to which the flowmeter is connected. The liquids drained should be wiped off after stopping the operation, and confirming the safety. (Photosensor) If the photosensor has not been operated, make sure that the wiring has been done correctly and that the volume position has been kept a correct position. In case that it turned out to be failed to operate, it is necessary to consider changing the sensor. Stop the operation including the sensor connected systems. The same action should be taken, when adhering the fluid to the sensor. 16. Where to contact H e a d q u a r t e r s: 3-17 Minamidaira, 4-chome Hino City, Tokyo 191-0041 Tel: 81-42-593-8811 / Fax: 81-42-593-8812 Tokyo Sales Office: 3-17 Minamidaira, 4-chome Hino City, Tokyo 191-0041 Tel:81-42-592-6111 / Fax: 81-42-592-6112 O s a k a S a l e s O f f i c e: Suite 915, East Exit Station Bldg. 20-14 Higashinakajima, 1-chome Higashiyodogawa ward, Osaka City Osaka-Fu 533-0033 Tel:81-6-4809-0411 / Fax:81-6-4809-0412 Fukuoka Sales Office: 2F K-2 bldg. 8-5 Hakataekiminami, 5-chome Hakata ward, Fukuoka City Fukuoka pref. 812-0016 Tel:81-92-482-2101 / Fax:81-92-482-2102 Sendai Sales Office: Suite 102, Izumi Kankoh bldg. 8-6 Shohgen, 1-chome Izumi ward, Sendai City Miyagi pref. 981-3132 Tel:81-22-218-2451 / Fax:81-22-218-2452

Warranty All products we manufactured have been carefully inspected and passed hrough the intraoffice inspection before shipping, but contact us at the nearest sales offices upon confirmation of the symptom, when a trouble occurs by chance. Warranty period The warranty period shall be for one year after the date of delivery. Scope of warranty When trouble for which we are liable has occurred during the warranty period, we will repair or replace it free of charge. Provided that in case of the following items they shall not be covered by warranty. In case that it is improperly handled and used. In case that it emerges from the causes except we delivered, In case that it is improperly remodeled and repaired, In case that it is due to natural calamity, disaster and others. In addition the warranty said above means the warranty of the single unit of the product we delivered. As to the damage triggered by the trouble of the delivery goods it cannot be warranted. 20090219