HNP. HNP073 Series. Flows up to 70 L/min Fluid viscosities to 700 cst PME HNP073

hyprofiltration.com/fsw

Standard Operating and Maintenance Instructions for Pumping System Model PS-90

FIK In-Tank Filters FIK. Max Flow: 170 gpm (643 lpm) Working Pressures to: Rated Static Burst to: Flow Range to:

Desiccant Air Breathers DBE. Section 3: TNK SCHROEDER INDUSTRIES ACCESSORIES 21

Principles of Filtration. Filter Elements. High Pressure Filters. Section 4. Tank-Mounted, Return Line and Medium Pressure Filters

HIGH PRESSURE FILTERS DFDK Series Inline Duplex Filters 4568 psi up to 90 gpm

Check Valves. Pilot Operated Check Valves. Vickers. 4CG-10, 20 Series 4CS-03, 20 Series 4CT-06/10, 20 Series. Basic Characteristics.

Tank-Mounted Suction Filter

D e s c r i p t i o n

Liquid ring vacuum pumps in compact design

Spin-On Filters SSF 24,25

E 328 E 498 Tank top mounting Connection up to G1½ / -24 SAE and SAE 2 Nominal flow rate up to 600 l/min / gpm

E 084 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 80 l/min / 21.1 gpm

Lubricating Oils Hydraulic Oils Turbine Oils Cutting and Cooling Mineral Oils Compressor Oils Synthetic Fluids Insulating Oils Quenching Oils

Operating Instructions Models and Hydrostatic Test Pumps

Standard Operating and Maintenance Instructions for Pumping System Model PS-150

Liquid ring vacuum pumps in compact design

Copyright, 2005 GPM Hydraulic Consulting, Inc.

Mobile High Pressure Compressor Unit for Compressing Air and Breathing Air. PE 250-TE with compressor control (optional equipment)

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1

HIGH PRESSURE DRILLING FLUID PUMP

Prop. 3-Way Pressure-Reducing Cart., Size 5 / SAE 08

Vickers. Flow Controls. Flow Controls FN, F(C)G, FRG. Released 6/94

/ /

hydro-pac, inc. Low-Pressure Gas Compressors 1500 to 6000 PSI

Max. working pressure 3650 bar / 52,200 psi Max. flow up to 50 liters / minute Fully made of stainless steel I N N OVATO R S T H E O U R

E 212 E 222 Tank top mounting Connection up to G1¼ / -20 SAE Nominal flow rate up to 220 l/min / 58.1 gpm

Liquid ring vacuum pumps in compact design

Pressure reducing valve, pilot operated, Model 3DR

Target Cleanliness Worksheet. Systemic Contamination Control

Liquid ring compressors

KEG PUMP. Range of Electric Keg Pumps

MANUAL BE SERIES Test Benches

MPS/MST SPIN - ON FILTER SUCTION - RETURN SERIES. Maximum working pressure 12 bar. Flow rates to 300 l/min

OPERATING INSTRUCTIONS

E 328 E 498 Tank top mounting Connection up to G1½ and SAE 2 Nominal flow rate up to 600 l/min

PRESSURE REDUCING (AND CHECK) VALVES RT/RG RCT/RCG. -03/06/10 (3/8, 3/4, 1-1/4) Threaded Connections / Sub-plate Mounting

E 094 E 103 E 143 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 135 l/min / 35.7 gpm

3-Way Safety Block DSV

ALF400 to 900, ALT-5/-9

E 158 E 198 E 248. Tank top mounting Connection up to G11 / 4 Nominal flow rate up to 250 l/min e d

Installation and commissioning instructions 255 series and 256 series

Air Eliminators and Combination Air Eliminators Strainers

F05MSV-N* CONTINENTAL HYDRAULICS FLOW CONTROL VALVE, NON-COMPENSATED WITH CHECK F05MSV-N* - FLOW CONTROL VALVE, NON-COMPENSATED WITH CHECK

DEWATERING PUMP SOLUTIONS. Pneumatic pumps

4-7 kw/ hp. Dual Output Compressors (Air/Nitrogen) Driving Nitrogen Forward

Operating Instructions Model and Hydrostatic Test Pump

Liquid ring vacuum pumps single-stage

Change-Over Pressure Filter DFDK

Proportional Pressure-Relief Cartridge Valve, Size 2...4

Auto Feed Lube, Auto Feed Tank ALF400 to 900, ALT-5/-9

Beamex PG PRESSURE GENERATORS. Beamex PGM PGV PGC PGHH PGPH PGL

Discontinued. Powers Controls. Technical Instructions Document No P25 RV Rev. 1, May, RV 201 Pressure Reducing Valves.

Liquid ring compressors

Avenger Model 33M Installation & Operation Instructions

G SPECIFICATION: TITLE: VOLUME: 4 REVISIONS:

Suction fi lters. SF2 500 series. Flow rate up to 800 l/min. Suction fi lters

Pressure reducing valve, direct operated

Inverse Prop. Pressure-Relief Cart., Size 2 4

Liquid ring compressor

DENISON HYDRAULICS vane pumps - single, double T6G - T67G - T6ZC

Chlorinator MODEL MK-I

Vaporizer Technique. FAS Flüssiggas-Anlagen GmbH

Air Operated Hydraulic Pumping Systems to 50,000 psi

CV08-20 Check Valve DIRECTIONAL VALVES. DESCRIPTION A screw-in, cartridge-style, hydraulic check valve for use as a blocking or load-holding device.

Additional sheet to leaflet Pressure regulators with safety assemblies, Print No Inlet pressures up to max. 1 bar Page 2

Cover headline. Cover subheadline. Check Valves

REFRIGERATION SYSTEM COMPONENTS

Cash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified

SERVICE MANUAL MODEL BA200AMST-S1 BREATHING AIR PANEL

IN-LINE CHECK VALVES CIT-02 / 03 / 06 / 10 (1/4,3/8,3/4,1-1/4) RIGHT ANGLE CHECK VALVES CRT / CRG-03 / 06 / 10 (3/8,3/4,1-1/4)

Series BLK Oil - air cooler

Manapak Sandwich Valves Series CM, CPOM, FM, PRDM, PRM, RM

Operating Instructions Models and Hydrostatic Test Pumps

P2* MODULAR SUBPLATES FOR ISO (CETOP 03) VALVES

61 Series Pilots for Pilot-Operated Pressure Reducing Regulators

Series 1, 3 and 4 Cv = /8" and 1/4" Ported Manually Operated Valves. 3-way/2-position, 5-way/2-position, 5-way/3position

3-Way Pressure-Reducing Cartridge, Size 2 4

Related Products: Auto Drain Valve. Model/Specifications. Model

CompAir provide high quality and reliable Nitrogen solutions

Vickers. Filters. Reservoir Vent Filters. Spin-on Air Filters & Adaptors. Rev. 3/98

GROUTEC SCOTT VICKERS. Grouting Equipment

ALF400 to 900, ALT-5/-9

Pressure reducing valve, pilot operated

McFarland TriTan, LLC.

SERVICE MANUAL MODEL BA200AA-S1 BREATHING AIR PANEL

INDUSTRIAL EXCESS ESS FLOW VALVES

Model: 43T. Bermad Pressure Relief Valve

ALF400 to 900, ALT-5/-9

SULLAIR SX Filtration Series ,000 scfm

1020 Industrial Drive, Orlinda, TN fax

Water valve Type WVO. Data sheet MAKING MODERN LIVING POSSIBLE

MICRO DIAPHRAGM GAS PUMPS

TEST BENCH FOR SAFETY VALVES

100C Air Compressor Kit

Installation, Operation, and Maintenance Manual Parker Balston Model N2-04 Nitrogen Generator

Displacement 12, , Maximum flow rate (at 1450 rpm) bar.

BOSS PULISCI PROVA IMPIANTI MEDIA

Filter-Regulator-Lubricator

Transcription:

HNP-021 Oil Purifier Contact Us: www.pall.com/contact Description The HNP-021 has been developed as a conditioner for hydraulic, lubrication and dielectric oils. It removes free and dissolved water, dirt, and free and dissolved air/gases. This portable unit is compact and easy to use. The HNP oil purifier provides a wide range of opportunities for cost savings including: increased equipment uptime, improved machine performance, reduced component replacement costs, reduced maintenance labor costs, and lower oil replacement and disposal expense. The Pall HNP fluid conditioning purifier removes 100% of free water and as much as 80% of dissolved water. It also removes 100% of free and entrained gases and up to 80% of dissolved gases. Particulate removal is achieved using a high Beta rated (ß 5(c) =1000) Ultipor III filter element to polish the fluid before discharge back to the system reservoir. Other replacement filter media grades are also available to suit application requirements. The HNP can be moved from one system to another or left as a permanent installation. The HNP purifier is simply connected to an electric supply, the inlet valve opened and reset and start buttons pressed to start the fluid purifying process. Automatic controls, integral to the unit, constantly monitor the operation and will safely shut down the system if fluid levels and pressures are outside normal limits. Safety features include high and low level float level switches, discharge relief valve (set at 100 psid/7 bar), inlet oil vacuum pressure switch and drip tray float switch. The HNP fluid conditioning purifier has been designed to be robust and reliable under the most arduous of conditions. All components are easy to maintain and filter elements are readily accessible for change out. Specifications Features Power Switch Lamp Test Button Alarm Reset Button Start Switch Discharge Pressure Gauge Recirculation Ball Valve Inlet Isolation Ball Valve Inlet Connection Information/Warning Lamps Power On Running Vessel Vacuum Low Fluid Level Low Fluid Level High Inlet Vacuum High Outlet Filter Blocked Drip Tray Full Vacuum Gauge Temperature Gauge Inlet Pressure Gauge

Outlet Connection Dry Weight: 350 lb (160 kg) Overall Dimensions: Length (mm) 42 in. (1060 mm) max. Width (mm) 24 in. (620 mm) max. Height (mm) Caster mounted: 35 in. (885 mm) Skid mounted: 33 in. (843 mm) Inlet Connection: 1" NPT Outlet Connection: 1" NPT Circulation Flow Rate: 7.5 gpm (28 L/min) Total Motor Power: 3 HP (2.25 kw) Fluid Compatibility: Units with nitrile seals are compatible with petroleum oils. Fluorocarbon seals are required for industrial phosphate esters and specified synthetics. Maximum Viscosity: 3000 SUS (700 cst) Temperature Range: +60 F (15 C) to +165 F (70 C) Maximum Pressure for Inlet: 6 psi (0.4 bar) Maximum Pressure for Outlet: 100 psi (7 bar) Normal Operating Vacuum: 24 in. Hg (-0.8 bar) Water Removal: Pall fluid conditioning purifiers remove all free water, free gases, dissolved water (up to 80%) and dissolved air (up to 80%) Description: The Pall HNP fluid conditioning purifier removes 100% of free water and as much as 80% of dissolved water. It also removes 100% of free and entrained gases and up to 80% of dissolved gases. Particulate removal is

achieved using a high Beta rated (ß 5(c) =1000) Ultipor III filter element to polish the fluid before discharge back to the system reservoir. Other replacement filter media grades are also available to suit application requirements. The HNP can be moved from one system to another or left as a permanent installation. The HNP purifier is simply connected to an electric supply, the inlet valve opened and reset and start buttons pressed to start the fluid purifying process. Automatic controls, integral to the unit constantly monitor the operation and will safely shut down the system if fluid levels and pressures are outside normal limits. Safety features include high and low level float level switches, discharge relief valve (set at 100 psid/7 bar), inlet oil vacuum pressure switch and drip tray float switch. The HNP fluid conditioning purifier has been designed to be robust and reliable under the most arduous of conditions. All components are easy to maintain and filter elements are readily accessible for change out. Performance HNP 021 Performance The HNP purifier is designed to reduce and maintain the water content in a fluid system to below the saturation level of the system fluid (<300 ppm for a typical mineral oil). However, where a large water ingress occurs, the HNP 021 can remove up to 12 gallons (45L) per day. Actual water removal rate depends on many variables including system design, oil type, temperature, viscosity, water content, emulsion stability, and additives. Flow Schematic Ordering Information Purifier P/N: HNP021 X Table1 Table2 Table3 Replacement Element P/N: Inlet: HM 55 420 Outlet: HC 9100 8 Table2 Table3 Air Breather: HC 0293 SEE5 Note: Choose from the options in the following tables to compile the specific Product Number.

TABLE 1 Description M6 220V 60 Hz 1 ph N4 230V 60 Hz 3 ph V4 460V 60 Hz 3 ph 14 575V 60 Hz 3 ph M5 220V 50 Hz 1 ph R3 380V 50 Hz 3 ph TABLE 2 Filter Medium FKZ KZ (ß <1 200) FKP KP (ß 3 200) EOS OS (105 µm mesh)* *OS mesh recommended for high viscosity fluids 1000 SUS at 100 F (220 cst at 40 C). Other replacement media grades are also available. TABLE 3 Seal Material H Nitrile Z Fluorocarbon Pall also designs and manufactures explosion protected purifiers. Customers with applications requiring purifiers for hazardous environments should consult the Sales Office. Contact Information