The products listed in this page are ECO-friendly products. * Please refer to page 4 for the details of ECO-friendly products. Model UAMR AD- L

Similar documents
The plastic bowl guard does not corrode. The draining method is selectable between the push type and the auto drain type.

Cautions : 1. Clogging of the element raises resistance to exhaust, thus lowering the

(1) Type (2) Thread size (T) (3) Wrench size specification : inch spec. (NPT, UNF) : mm spec. (M, R)

Cautions : 1. The gauge orientation on the GPU and GPM types can be changed by using

Cautions : 1. Be careful when you release the Stop Fitting with some internal pressure

(1) Type (2) Cylinder dia. (3) Gripper action : Single-acting closing gripper (normally open) (4) Holder type

(2) Effective sectional area (no code for mini type) (3) Intake-side shape (no code for mini type) : Quick-fitting joint type : Taper pipe thread type

(1) Name of tube (2) Tube dia. (O.D./I.D.) (3) Tube length. (4) Tube color. Model UD0425. UD1290 O.D. I.D. (mm) UD1075 UD0860 UD

(1) Union Filter for positive and negative pressure (2) Filter size. (3) Tube dia. (4) Holder option : without Holder : with Holder

(1) Type. (2) Tube dia. (ød) : ø8mm (ø5/16in.) (3) Thread size (T) (4) Specification. Fluid medium. Air, water * 1, * 2, * 3 Max. operating pressure

(1) Type (2) Tube dia. (ød(1)) (3) Thread size (T) (4) Wrench size specification : inch spec. (NPT, UNF) : mm spec. (M, R)

Model PCøD-TSUS PC4-M6SUS PC4-01SUS PC4-02SUS PC6-M5SUS PC6-M6SUS PC6-01SUS PC6-02SUS PC16-03SUS

Model SPCøD-T SPC4-M5 SPC4-M50 * 1 SPC4-M6 SPC4-02 SPC6-M5 SPC6-M6 SPC6-01 SPC6-02 SPC16-03

(1) (2) (3) (4) No indicator type Digital pressure sensor with large display 30mm negative pressure gauge Air

Push-In Fitting Type Silencer

Coiling Tube with Twist-Proof Fitting

Push-In Fitting Type Pressure Gauge

Change Valve. Push-In Fitting Type Three-way Changeover Valve. Changeover Air Direction by 90. Lightweight and Compact Design.

Insert Ring. Protection Ring from Tube Deformation. Protect tubes from deformation. Ultra soft tube is connectable to Fitting.

Pressure Gauge Series

Hand Valve Series. Push-In Fitting Type Shut-off Valve (Residual Pressure Release Valve) Control Open/Close for Air Supply.

Tube Cutter with Measuring tape built-in

Tube for Clean Environment Polyurethane Tube Clean-Room Package

Push-In Fitting Type with Stop Valve

Anti-spatter Tube. Spatter-Proof Tube for Pneumatic Piping. Polyamide type Tube Coated with Flame-Retardant Resin(Equivalent to V-0 )

Speed Controller Constant Flow

(1) Size (Overall dimensions: H W) (2) Bending radius. (3) Body color : Black : Ivory (102, 202, 203, 204, 206 only)

Static dissipative Resin (Surface Resistivity : 10 4 ~10 7 Ω).

Speed Controller Anti-spatter Series

Coiling Tube Series. Coiling Tube for General Pneumatic Piping. Coiling Tube for General Pneumatic Piping. Suitable for Air Gun or Air Driver.

Multi Core Tube for General Pneumatic Piping

Polyurethane Tube. Straight Tube for General Pneumatic Piping. Excellent in Flexibility. Suitable for Compact Piping Requiring Small Bending Radius

(1) Size (Overall dimensions: H W) (2) Bending radius. In case of ordering, please apply Model code in the following chart. H HF K a.

Tube for General Pneumatic Piping

Suitable for Semi-Conductor, Measuring Instrument, Printing and Medical Industries

Ball Valve Series. Push-In Fitting Type Shut-off Valve. Control Open/Close Air Supply. Ensure Effective Area for Variety of Tube Dia.

Pad Swinging Attachment

Die Temperature Control Fitting Series

Series AS-FPQ/AS-FPG. Speed Controller with One-touch Fitting for Clean Room. Speed controllers for clean room use

Ejector for Conveying particles, powder and fibers Vacuum GeneratorVRL

Pilot Check Valve: Metal Body Type

Series SFD. Clean Air Filter. Variations. Made to Order. Type. Cartridge (replaceable element) Disposable (non-replaceable element) Up to 100

Operation Manual Air Saver Unit ASV5000 Series

Related Products: Auto Drain Valve. Model/Specifications. Model

COMMON PRECAUTIONS Data Sheet - Be Sure To Read Before Handling Page 1 of 6

Maximum 0.85 MPa pressure setting Long-life, high flow perfect for balancer applications

New Product. Air Consumption 70% Down. Precision Regulator Air Saving Type. RPE Series PRECISION REGULATOR RPE SERIES CC-1072A

Regulator for 2 MPa ARX 20. How to Order. Bracket. Pressure gauge. Port size 1/8 1/4. Panel nut

Series IRV1000/2000/3000

Series AMJ. Drain Separator for Vacuum

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

/ Air Line Kit AL - M1202. / OPERATION MANUAL P1 - P9 / English P11 - P19 OM-K0651

PVC Quick Drain Valve

Recommended applicable tubing. Specifications. Operating vacuum pressure. 20 C to 80 C Threads. Principal parts material

Industrial Filter. FGD series

Needle valve. Contents. User s Manual. (1) Be sure to read the following warranty clauses of our product 1. (2) General operating instructions 2

reduces flow setting time and setting errors!

Air operated valve. VGA342R Series

Wafer Check Valve. Contents. User s Manual. (1) Be sure to read the following description of our product warranty 1

Compact Manometer. Pressure measurements can easily be taken any time, anywhere. POWER LIGHT

KTM OM-2 SPLIT BODY FLOATING BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

No.IL02-OM00011-A PRODUCT NAME LOCK UP VALVE. MODEL/ Series IL201 IL211

Regulator. Accessory. Description. Symbol. Nil. With bracket. B With round. Port size. (Without limit indicator) With set nut (For panel mount)

Power Valve: Precision Regulator. High precision, large capacity relief regulator

B84G - Excelon Plus Modular System General purpose filter/regulator

B84G - Excelon Plus Modular System General purpose filter/regulator

Pressure Relief 3 Port Valve New. Sonic Conductance 45% With the indicator window Step1. With locking holes

B74G - EXCELON Modular System General purpose filter/regulator

Doc. No.SYJ300-OMO0002-A. Air Operated Valve PRODUCT NAME. SYJA300 / SYJ3000 Series MODEL/ Series

Port size. Model Screw-in ZFA10 1/8 ZFA20 1/4 ZFB10 ZFB20 ZFB30 ZFB40 ZFC5 ZFC7

Direct Operated Precision Regulator Modular Style. Standard Specifications

// ADapters GUIDelines

Specifications. Construction. 2 port valve/series VHK2 3 port valve/series VHK3. Component Parts. Standard style. Flame resistant style

Series variation. Silencer. High damping effect and 2 types of materials. Applicable cylinder bore size (mm) Effective sectional area (mm 2 )

SeriesTRBU. Flame Resistant (Equivalent to UL-94 Standard V-0) FR Double Layer Polyurethane Tubing

IR1000-A IR1010-A IR1020-A

Standard Specifications. Fluid Proof pressure Maximum operating pressure. Regulating pressure range

Vacuum Saving Valve Series ZP2V How to Order ZP2V A5 03 Connection thread symbol for the pad Male thread connection Symbol Thread Applicable fixed ori

Clean Speed Controller with One-touch Fitting

ROTARY JOINTS NHRC Structural Diagram

Vacuum Regulator. IRV10/20 Series. Weight reduced by. RoHS ARJ ARX AMR ARM ARP IR -A IR IRV VEX SRH SRP SRF ITV

Model GP PRESSURE REDUCING VALVE Installation & Operation Manual

Filter regulator. Accessory. Description. Symbol. B With bracket With round. Port size. (Without limit indicator) Body size.

OPERATION MANUAL Please read this Operation Manual carefully before use, and file for future reference.

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO

Low torque Metal seal type Rotary joint

CHECK VALVES GPCVC Structural Diagram

Model GPR Primary Pressure Regulating Valve. Instruction Manual

Filter-Regulator-Lubricator

Auto Feed Lube, Auto Feed Tank ALF400 to 900, ALT-5/-9

Compact Manometer. Pressure measurements can easily be taken any time, anywhere.

Spilt body Flange ball valve. TC-205MFF-PN1640 User Manual English Version. Document No: TC-205MFF-PN1640.Ur-manual. Date: 2007/04/2617. Version: 1.

Lab Cock. Contents. User s Manual (1) Be sure to read the following warranty clauses of our product 1. (2) General operating instructions 2

F l o w c o n T R o l v a l v E S

ALF400 to 900, ALT-5/-9

VACUUM REGULATORS CONTENTS

Torque Specifications

Small Vacuum Regulator Series

WHEATLEY WHEATLEY SERIES 500 SWING CHECK VALVE. Installation, Operation and Maintenance Manual

DBML-60/80 Squeeze Tool

Transcription:

his modular type unit offers a rich variety of combinations and features easy maintenance. Air Filter (1) (2) (3) (4) Regulator Mist Filter or Micromist Filter (5) (6) (1) ype (2) Unit combination Code Air Filter Mist Filter Micromist Filter Regulator (3) Flow Rate : 300l/min(ANR) (10.6SCFM) (4) Connection port () : Rc1/4 : Rc3/8 (5) Drain cock : Push type manual drain cock : Auto drain cock (6) Flow direction : Left to Right : Right to left (7) Pressure Gauge (only for UADR, UAMR, UAR) : equipped with a gauge : Without gauge (7) he products listed in this page are ECO-friendly products. * Please refer to page 4 for the details of ECO-friendly products. UAR300-- - - UAR300-02-MD- UAR300-02-MD- L UAR300-03-MD- UAR300-03-MD- L UAR300-02-AD- UAR300-02-AD- L UAR300-03-AD- UAR300-03-AD- L Cautions *1. For, please select a fl ow direction. *2. Build-to-order production Package specifi cation 1 pc. in a bag UADR300-- - - UADR300-02-MD- UADR300-02-MD- L UADR300-03-MD- UADR300-03-MD- L UADR300-02-AD- UADR300-02-AD- L UADR300-03-AD- UADR300-03-AD- L UAD300-- - - UAD300-02-MD- UAD300-03-MD- UAD300-02-AD- UAD300-03-AD- UAMR300-- - - UAMR300-02-MD- UAMR300-02-MD- L UAMR300-03-MD- UAMR300-03-MD- L UAMR300-02-AD- UAMR300-02-AD- L UAMR300-03-AD- UAMR300-03-AD- L UAM300-- - - UAM300-02-MD- UAM300-03-MD- UAM300-02-AD- UAM300-03-AD- Before using the PISCO device, be sure to read the "Safety Instructions", "Common Safety Instructions for Products Listed in his Manual" on page 13 to 15 and "Common Safety Instructions for Controllers" on page 64 and "Common Safety Instructions for Filter and Regulator Unit" on page 94. Caution : 1. When discharging secondary side air open to atmosphere, sympathetic vibration may be generated by an influence of a flow. Because there is a danger of causing such as the internal damage, please avoid the use such as discharging secondary side air open to atmosphere over a prolonged period of time. : FA300- - D FRF300- - D : FD300- - D : FM300- - D : RVF300- - RVF300- - S FRF300- - D Filter element (5µm) FE300A S20 S20 Square pressure type (direct mount type) GK46-B20 0.5 0 MPa 1 P4 * When replacing fi lter element, please exchange (P4) to new each time. S38 Mist element (no holder) (0.3µm) FE300DN Mist element set (with holder) FE300DK S38 Micro-Mist element (no holder) (0.01µm) FE300MN Micro-Mist element set (with holder) FE300MK S38 96

Be sure to read the following instructions before selecting and using the PISCO devices. Also read the detailed instructions for individual series. Warnings: 1. Each device has its control direction, so check it in the manual and by the mark on the device before use. Mistaking the control direction may cause injuries on the operator or damage to the equipment. 2. Do not give tension, twist or bending to the controllers. Also, do not drop or give excessive shocks to them. Such careless handling can inflict damage to them. 3. When the controller has a lock nut on it, tighten it by hand without using a tool. ightening with a tool may damage the lock nut or the controller body. Also, the incomplete tightening may lead to a loose lock nut, which in turn may render the initial setting useless. 4. Use clean air as the pressure source. Dust or sludge may upset the control setting. Cautions : 1. he safety instruction of tube fitting part should be referred to "Common Safety Instructions for Quick-Fitting Joint". 2. Notes on installation (1) ighten with a proper tool, using hexagonal or knurled part. (2) In tightening the screw, use the tightening torque recommended in the following table. Use of a torque higher than the recommended level may damage thread or deform gasket, thus causing leakes. Use of a torque lower than the recommended level may cause loose screw and leakage. able. Recommended ightening orque Hexagonal part hread ype hread size ightening torque M3 0.5 0.7N m (0.52lbf ft) Metric thread M5 0.8 1 ~ 1.5N m (0.74 ~ 1.11lbf ft) M6 1 2 ~ 2.7N m (1.48 ~ 1.99lbf ft) R1/8 7 ~ 9N m (5.16 ~ 6.64lbf ft) aper pipe thread R1/4 12 ~ 14N m (8.85 ~ 10.33lbf ft) R3/8 22 ~ 24N m (16.23 ~ 17.70lbf ft) R1/2 28 ~ 30N m (20.65 ~ 22.13lbf ft) Unified fine thread No.10 ~ 32UNF 1.5 ~ 1.9N m (1.11 ~ 1.40lbf ft) 1/16 ~ 28NP 7 ~ 9N m (5.16 ~ 6.64lbf ft) 1/8 ~ 27NP 7 ~ 9N m (5.16 ~ 6.64lbf ft) National Pipe hread aper 1/4 ~ 18NP 12 ~ 14N m (8.85 ~ 10.33lbf ft) (American standard) 3/8 ~ 18NP 22 ~ 24N m (16.23 ~ 17.70lbf ft) 1/2 ~ 14NP 28 ~ 30N m (20.65 ~ 22.13lbf ft) Parallel pipe thread G3/8 G1/2 1/2 ~ 1 turn after hand-tightening Knurled part hread ype hread size ightening torque M5 0.8 Metric thread M6 1 1/6 turn after hand-tightening M10 1 G1/8 Parallel pipe thread 1/2 ~ 1 turn after hand-tightening G1/4 3. Notes on removal (1) Loosen it with a proper tool, using the hexagonal or knurled part. (2) Remove sealant sticking to the thread on the mated equipment. he sealant left sticking may enter the peripheral equipment and cause trouble. 4. he Fixed Orifice ype Joint and Constant Flow Speed Controller, which have an orifice, have variation in a flow characteristic. When you require a strict control of airflow, please consult with PISCO. 5. When the product itself generates heat by adiabatic compression, please control the operating temperature to be within the specification's range including such heat. 64

Be sure to read the following instructions before selecting and using the PISCO devices. Also read the detailed instructions for individual series. Warnings: 1. When installing the unit, provide adequate support and fix it securely. Looseness or dripping off of the unit may cause injuries. 2. Do not use the unit with the explosion-proof casing (bowl guard) removed. Should the bowl break, pieces may fly apart to cause injuries. 3. Be sure to set the lock button on the air filter, mist filter or micromist filter to "lock" before use. Otherwise the explosion-proof casing and the bowl may fall off to cause injuries. 4. Before performing maintenance, checks or replacement, be sure to turn off power, shut off air supply, and make certain that the pressure inside the piping has dropped to zero. 5. Do not use the unit in a fluid or atmosphere containing corrosive gas or organic solvent gas. Such use may deteriorate the unit body, thus causing leakage or damage. Cautions : 1. Be sure to install the air filter, mist filter or micromist filter vertically. Improper installation may cause faulty draining. 2. Air-filter, mist-filter, micro-mist-filter, and filter-regulator continue to discharge air and drain until the pressure inside reaches the following pressure even turning the drain knob: the manual drain type model is 0.05MPa, and auto drain type is 0.15MPa. If it requires a long time until supply pressure reaches 0.15MPa, please consult with Pisco. 3. When a manual drain type is selected, please discharge drain from the filter before reaching MAX. DRAIN LEVEL. Otherwise, it becomes the cause that drains flows into a secondary side. 4. Confirm the IN side of air supply by the mark. Wrong piping may drop the unit performance. 5. Do not apply excessive air pressure (Max. 123.3psi (0.85MPa)) to Regulator, which may cause malfunctions. 6. Please adjust the pressure of the regulator by pulling the handle up and in the direction of increasing pressure, and make sure to lock the handle by pushing it down after adjustment. 7. Please operate the drain knob by fingers. 8. Please use 6mm ID nylon tube when connecting a drain tube to push type manual drain valve. Please do not bend the tube very close to the valve. 9. he manual drain valve can rotate freely, so that it is not necessary to disconnect the tube when discharge the drain manually. 94

his Safety Instructions aim to prevent injuries to human bodies and damage to properties by requiring proper use of PISCO devices. Also the relevant requirements of ISO 4414 and JIS B8370 must be observed. ISO 4414: Pneumatic fluid power Recomendations for the application of equipment to transmission and control systems. JIS B 8370: General standards for pneumatic systems Safety instructions are classified into "Danger", "Warning" and "Caution", depending on the degree of danger or damage involved when the safety instructions are not complied with in handling the equipment. Danger : Failure to heed the warning of apparent danger may result in death or serious injuries. Warning : Failure to heed the warning of conditionally dangerous situations may result in death or serious injuries. Caution : Failure to heed the warning of conditionally dangerous situations may result in minor or not too serious injuries or damage to properties. Warning : 1. Make a selection of pneumatic equipment. (1) Well knowledgeable and experienced persons such as a pneumatic system designer or who is in charge of deciding specification should select pneumatic equipment. (2) he applicable conditions of the products in this catalogue are diverse. herefore, judge the conformity of systems with required analysis or tests by system designers or persons who is in charge of deciding specifications. he guarantee of initial performance and safety of the system is on responsibility of the person who decides specifications. Hereafter, examine all the specification with updated products catalogues and technical documents in order to avoid malfunctions of equipment, and then develop systems. 2. Handle pneumatic equipment with enough knowledge and experience. (1) Mishandling of compressed air is dangerous. Conduct assembly, operation and maintenance of devises with pneumatic equipment by persons with enough knowledge and experience. 3. Do not operate and remove the equipment until safety is confirmed. (1) Conduct inspection and maintenance of equipment after confirming fail-proof measures of work pieces or runaway-proof device are properly working. (2) When removing equipment, make sure that above safety measures are conducted. hen, stop air supply and electric source of equipment making sure the pressure inside the system is zero before removing equipment. (3) When re-activate equipment, make sure safety measures against fly-out are taken and re-activate equipment with care. * Safety Instructions are subject to change without advance notice. 13

PISCO products are designed and manufactured for use with general industrial machinery and equipment. herefore be sure to observe the following safety instructions: Danger Warning : 1. Avoid the following uses for PISCO devices: (1) Use under conditions not specified for the device (2) Use in any outdoor environment (3) Use in locations where the device is exposed to excessive vibration or shocks (4) Use in locations where the device is exposed to any corrosive gas, inflammable gas, chemicals, seawater, or vapor. * Certain PISCO devices, however, can be used in environments as described above. herefore check on the specifications for the use of individual devices. 2. Do not disassemble or remodel the PISCO devices in such a way as may affect the basic structure, performance or function of them. 3. Never touch the release ring of the Quick-Fitting Joint when there is pressure working on it. ouching may release the ring, which in turn may cause the tube to fall out. 4. Avoid too frequent switching of air pressure. Otherwise the device body may heat up to cause burns on you. 5. Do not allow tension, twist or bending forces to act on the joints. Undue forces may damage the joint body. 6. For applications in which the threaded side or the tube connection side is subject to vibration, use Rotary Joints, High Rotary Joints or Multi-Circuit Rotary Blocks only. Swinging or rotation may damage the joint body. 7. For applications with hot water of 60 C (140 F) or above or thermal oil, use no other joints than Die emperature Control Fitting, ube Fitting Stainless SUS316, ube Fitting Stainless SUS316 Compression Fitting, and All Brass Compression Fitting. Heat or hydolysis may damage the joint body. 8. For applications in which the scattering of static electricity or charging must be prevented, use no other joints than EG Joints. Static electricity may cause system malfunction or trouble. 9. Never use joint other than ube Fitting Spatter or ube Fitting Brass where they are exposed to spatter. Otherwise can cause fire. 10. Carry out maintenance and checks of equipment only after turning power off, shutting fluid off and making certain that the pressure in the piping has dropped to zero. Please conduct maintenance after confirming following points. (1) Make sure that maintenance is safe for all the systems involving PISCO products. (2) When re-activate equipment after maintenance, make sure safety measures against fly-out are taken and re-activate equipment with care. (3) Please secure space for maintenance when the circuit is designed. 11. When the fluid is admitted to the equipment and if there is a possibility to cause damage to it due to leakage, conduct safety measures such as protect cover beforehand. Caution : 1. Do not use PISCO devices with the following equipment: (1) Equipment used for the sustenance or control of people's health or lives (2) Equipment used for the movement or transport of people (3) Equipment used specifically to ensure safety : 1. In installing the piping, be sure to remove dust or drainage from within the piping. Dust or drainage left unremoved may enter other equipment, thus causing troubles. 2. When using an ultrasoft tube to connect to a Quick-Fitting Joint, be sure to use an insert ring in the bore of the tube. Otherwise the tube may fall out to cause leakage. 3. When you use tubes of brands other than ours, be sure to confirm that the outside diameter of the tubes satisfies the tolerance specified able 1. able 1. ube O.D. olerance mm size Nylon tube Urethane tube ø1.8mm ±0.05mm ø3mm ±0.15mm ø4mm ±0.1mm ±0.15mm ø6mm ±0.1mm ±0.15mm ø8mm ±0.1mm ±0.15mm ø10mm ±0.1mm ±0.15mm ø12mm ±0.1mm ±0.15mm ø16mm ±0.1mm ±0.15mm inch size Nylon tube Urethane tube ø 1 /8 ±0.0039in. ±0.0059in. ø 5 /32 +0.0039in. ±0.0059in. ø 3 /16 ±0.0039in. ±0.0059in. ø 1 /4 ±0.0039in. ±0.0059in. ø 5 /16 +0.0039in. ±0.0059in. ø 3 /8 ±0.0039in. ±0.0059in. ø 1 /2 ±0.0039in. ±0.0059in. ø 5 /8 ±0.0039in. ±0.0059in. 14

4. Cautions on the fitting of tube (1) Make certain that the end of the tube is cut at right angles, the tube surface is free from flaws, and the tube is not deformed into an ellipse. (2) When fitting a tube, insert the tube to the tube end completely as drawings shown below to prevent leakage. ube end : GOOD Release-ring : NG ube Lock claws Sealing: Elastic-sleeve ube is not inserted fully to tube end. (3) On completion of fitting, make certain that the tube does not come out at your pulling. 5. Cautions on the release of tube (1) Before releasing the tube, make certain that the pressure inside the tube is zero. (2) Push the release ring fully inside and pull out the tube. Unless you push it completely in, the tube may not come out and scrapings of tube may be left inside the joint. 6. Cautions on the installation of joint body (1) When installing the joint body, tighten it with a proper tool, using the outside or inside hexagon. (2) In tightening the screw, use the tightening torque recommended in able 3. Use of a torque higher than the recommended level may damage thread or deform gasket, thus causing leaks. Use of a torque lower than the recommended level may cause loose screw and leakage. (3) With the joint whose piping direction will not change after tightening, make adjustment within the recommended range of tightening torques. able 3. ightening orque, Sealock Color and Gasket Material hread type hread size ightening torque Sealock color Gasket material M3 0.5 0.7N m (0.52lbf ft) M5 0.8 1.0 ~ 1.5N m (0.74 ~ 1.11lbf ft) n/a SUS304, NBR M6 1.0 2.0 ~ 2.7N m (1.48 ~ 1.99lbf ft) Metric thread M3 0.5 0.5 ~ 0.6N m (0.37 ~ 0.44lbf ft) M5 0.8 1.0 ~ 1.5N m (0.74 ~ 1.11lbf ft) M6 0.75 0.8 ~ 1.0N m (0.59 ~ 0.74lbf ft) n/a POM (Polyacetal) M8 0.75 1.0 ~ 2.0N m (0.74 ~ 1.48lbf ft) R1/8 7 ~ 9N m (5.16 ~ 6.64lbf ft) aper pipe thread R1/4 12 ~ 14N m (8.85 ~ 10.33lbf ft) R3/8 22 ~ 24N m (16.23 ~ 17.70lbf ft) White n/a R1/2 28 ~ 30N m (20.65 ~ 22.13lbf ft) Unified thread No. 10-32UNF 1.0 ~ 1.5N m (0.74 ~ 1.11lbf ft) n/a SUS304, NBR 1/16-28NP 7 ~ 9N m (5.16 ~ 6.64lbf ft) 1/8-27NP 7 ~ 9N m (5.16 ~ 6.64lbf ft) National Pipe hread aper 1/4-18NP 12 ~ 14N m (8.85 ~ 10.33lbf ft) (American standard) 3/8-18NP 22 ~ 24N m (16.23 ~ 17.70lbf ft) Gray n/a 1/2-14NP 28 ~ 30N m (20.65 ~ 22.13lbf ft) Recommended tightening torque for silencer hread ype hread Size ightening orque M5 0.8 Metric thread M6 1.0 M10 1.0 1/6 turn after hand-tightening G1/8 Parallele pipe thread G1/4 G3/8 1/2 ~ 1 turn after hand-tightening G1/2 7. Cautions on the removal of joint body (1) When removing the joint body, loosen it with a proper tool, using the outside or inside hexagon. (2) Remove sealant sticking to the thread on the mating equipment. he sealant left sticking may enter the perpheral equipment and cause trouble. 8. Clean-room package option * he product is washed by clean air after assemblying in the normal assembly process as same condition as standard specification model. hen, it is packed in ISO class 6 clean-room. 15