Series ZL. Multistage Ejector. New models! ZL212 large flow rate type and ZL112 with valve. ZX ZR ZM ZY ZH ZU ZL ZF ZP ZCU

Multistage Ejector Series ZL

Multistage Ejector Series ZL

VACUUM REGULATORS CONTENTS

Series ZFC. Air Suction Filter In-line Type with One-touch Fittings

Series IRV1000/2000/3000

Compact Pressure Switch

Compact Pressure Switch

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

Maximum 0.85 MPa pressure setting Long-life, high flow perfect for balancer applications

Vacuum Regulator. IRV10/20 Series. Weight reduced by. RoHS ARJ ARX AMR ARM ARP IR -A IR IRV VEX SRH SRP SRF ITV

Precision Regulator. Series Model Regulating pressure range Port size Page

E8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm)

Series SFD. Clean Air Filter. Variations. Made to Order. Type. Cartridge (replaceable element) Disposable (non-replaceable element) Up to 100

Data Sheet. Vacuum generators

G1/8 G1/8. Model 0 bar -0,1 bar -0,2 bar -0,3 bar -0,4 bar -0,5 bar -0,6 bar -0,7 bar -0,8 bar

Series 10-IRV10/20. Vacuum Regulator C08 IRV C08 IRV 20 A. How to Order. Standard connections. Single sided connections. Accessory w Nil G ZN ZP ZA ZB

Power Valve: Precision Regulator. High precision, large capacity relief regulator

Pilot Check Valve: Metal Body Type

EXH. Specifications. Descriptions. Min. working pressure MPa

Self-priming makes priming unnecessary Exhausts the air inside the suction pipe to suck up liquid. Air operated type.

LMU100/200 Series. Standard Specifications

Related Products: Auto Drain Valve. Model/Specifications. Model

New Product. Air Consumption 70% Down. Precision Regulator Air Saving Type. RPE Series PRECISION REGULATOR RPE SERIES CC-1072A

Direct Operated Precision Regulator Modular Style. Standard Specifications

10 switches simultaneously. The settings of the master sensor (source of copy) can be copied to the slave sensors. Reducing setting labor

Auto Feed Lube, Auto Feed Tank ALF400 to 900, ALT-5/-9

ALF400 to 900, ALT-5/-9

Digital Flow Switch. Series PFM7

Plant Air Energy Saving

Proportional pressure regulators VPPE

Process Pump Automatically Operated Type (Internal Switching Type) Air Operated Type (External Switching Type) How to Order

For Air Pressure. AP-30 Series. Digital Display & Digital Control. EASY-TO-SEE 2-color display. Two-color digital display pressure sensor

Vacuum Pad with Ejector. Series ZHP

2/ Port G1/4

Booster Regulator/Air Tank

Air Saving Valve. Pressure Valve Flow Valve

Digital electro-pneumatic regulators Series ER100

How to Order. Rc NPT 1/8 1/4 3/8 1/2

The Discussion of this exercise covers the following points:

Low Friction Cylinders

Process Pump. Self-priming makes priming unnecessary. Air operated type. Air supply port. 5 port solenoid valves. Application Example

Series AMJ. Drain Separator for Vacuum

Air Saving Valve reduction in 40% air consumption 40% air consumption Air consumption reduction ratio (%) Flow valve Flow valv

Pneumatic spool valve islands

Visualize Nitrogen Gas Consumption

Slit Valve. XGT Series. Low particle generation. With end lock mechanism. Service life of two million cycles. XLA XL XL Q D- XSA XVD XGT CYV

How to Order. Body size. Pressure: 2 MPa. Pressure increase ratio 0 Twice. Symbol. Thread type. Body size

Process Pump. Series PAF3000/Series PAF5000

Air Saving Valve. Series ASQ. Series ASR. Pressure Valve. Flow valve TMH ASD AS AS-FG AS-FP AS-FM ASP ASN AQ ASV AK VCHC ASS. r r AS-FE KE 10 0.

Specifications. Construction. 2 port valve/series VHK2 3 port valve/series VHK3. Component Parts. Standard style. Flame resistant style

COMMON PRECAUTIONS Data Sheet - Be Sure To Read Before Handling Page 1 of 6

WARNING. Work drop prevention check valves FPV series. Vacuum accessories. Safety handling of workpiece with several pads

OWNER S TECHNICAL MANUAL

Process Pump. PAF3000 Series/PAF5000 Series

IR1000-A IR1010-A IR1020-A

Port size. Model Screw-in ZFA10 1/8 ZFA20 1/4 ZFB10 ZFB20 ZFB30 ZFB40 ZFC5 ZFC7

Smooth Vent Valve. Series XVD XL XL Q D- XVD XGT CYV

Air preparation units

Air Cylinders Drive System Full Stroke Time & Stroke End Velocity

Precision Regulator. IR1000/2000/3000 Series ARJ ARX AMR ARM ARP IR -A IR IRV VEX SRH SRP SRF ITV IC ITVH ITVX PVQ VY1 AP100.

Pneumatic valve islands

Integral type Differential pressure flowmeter VNT Series

INSTALLATION & MAINTENANCE INSTRUCTIONS

FLUID POWER FLUID POWER EQUIPMENT TUTORIAL OTHER FLUID POWER VALVES. This work covers part of outcome 2 of the Edexcel standard module:

3-Way Safety Block DSV

Product Information. Gripper for small components MPC

Operation Manual Air Saver Unit ASV5000 Series

Smooth Vent Valve XVD. Series

435 psi (3.0 MPa) Maximum Supply Pressure High Pressure Electro-Pneumatic Regulator. Maximum supply pressure. Set pressure range.

Compact Manometer. Pressure measurements can easily be taken any time, anywhere. POWER LIGHT

Low torque Metal seal type Rotary joint

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

[Instruments for vacuum measurement, checking and adjustment] 3

Nugget 120 V14 Series

Regulator/Modular Style AR1000 to 6000

Lecture 19 PRESSURE-CONTROL VALVES [CONTINUED]

Process Pump Automatically Operated Type (Internal Switching Type) Air Operated Type (External Switching Type) How to Order. Option. Symbol.

- From 2005 year model, replacing with RM250 with 2-stroke engine, RM-Z450 with 4-stroke engine was introduced in the market. - From 2008 year model,

RP series Rotor Pumps

Nugget 120 V14 Series

Vacuum Saving Valve Series ZP2V How to Order ZP2V A5 03 Connection thread symbol for the pad Male thread connection Symbol Thread Applicable fixed ori

(1) Type (2) Thread size (T) (3) Wrench size specification : inch spec. (NPT, UNF) : mm spec. (M, R)

AMS 2710 PCB pressure sensor module with V output

Standard Specifications. Fluid Proof pressure Maximum operating pressure. Regulating pressure range

Smooth Vent Valve. XVD Series

Clean Gas Filter. SF Series. Cartridge Type/Disposable Type IDFA IDFB IDH ID IDG IDK AMG AFF AM AMD AMH AME AMF ZFC SF SFD LLB AD GD SFC10

GRAPHIC DIVISION. 3D drawings available at

1.0. ISE70/71 Series CAT.ES A. MPa/1.6 MPa. 3-Screen Display High-Precision Digital Pressure Switch. Angled display.

Model 130M Pneumatic Controller

5.0 MPa Maximum Supply Pressure. New. Stepless control of air pressure proportional to an electrical signal. Series ITVX CAT.

Coiling Tube with Twist-Proof Fitting

IRV Series. Vacuum Regulator. New RoHS. New and Improved. Series IRV10/20

Series AS-FPQ/AS-FPG. Speed Controller with One-touch Fitting for Clean Room. Speed controllers for clean room use

(1) Name of tube (2) Tube dia. (O.D./I.D.) (3) Tube length. (4) Tube color. Model UD0425. UD1290 O.D. I.D. (mm) UD1075 UD0860 UD

TH-1800-T TRX-700-CNG Converter

The Ins and Outs of I/P Transducers

VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10

OPERATION. Estimated kerf width compensation. HPR260 Manual Gas Instruction Manual 4-9

Inverse Proportional Pressure-Relief Cart., Size 2 4

Transcription:

CAT.ES0-1 B Space Saving acuum Ejector & acuum Pump System Conventional ZX 21. mm mm ZQ Series ZQ Width mm Weight 9 g Single unit with vacuum pressure switch and suction filter Ejector Pump System Digital vacuum pressure switch with ED display 1 NPN output + Analog output 1 PNP output + Analog output 2 NPN outputs 2 PNP outputs With one-touch fitting

Ejector Module System Adsorption Transfer System by Ejector Equipment (Ejector supply valve / acuum release valve / Restrictor / acuum pressure switch / Filter) that is needed for the ejector adsorption transfer system has been integrated to achieve efficient assembly work and a compact design. Compressor Air filter Series AF Mist separator Series AM Regulator Series AR Ejector module Pressure gauge for vacuum Series GZ Refrigerated air dryer Series IDF Ejector System Equipment Series Space saving vacuum ejector Series ZQ acuum module Series ZX acuum ejector Series ZM Ejector System Equipment Features Width mm Weight 9 g (Single unit with vacuum pressure switch and suction filter) Can also accommodate a vacuum pump for the adsorption transfer of small items such as electronic parts. Using an ejector with a 2-stage nozzle, the ejector system can be used most efficiently. Ejector nozzle dia. (mm) ø0. to ø1.0 ø0. to ø1.0 ø0. to ø1.3 Double solenoids arge vacuum module Series ZR provide a self-holding function. Necessary functions can be combined through modular design. Can also accommodate a vacuum pump. ø1.0 to ø2.0 Equipment Supply valve acuum release valve acuum switch Series acuum ejector Series ZH Multi-stage ejector Series Z Ejector valve Series ZYY/ZYX Air suction filter Series ZFA Air suction filter Series ZFB acuum pad Series ZP Free mount cylinder for vacuum Series ZCUK acuum switch Series ZS Refer to Best Pneumatics 2004 ol. 13 catalog for the detailed Ejector System Equipment and Related Products. Filter Single Unit Equipment Features Nozzle diameter ø0. to 1.3 mm Can be connected with the combination of a onetouch and a screw-in connection. Suction flow rate increased by a 3-stage diffuser construction. Functions such as a digital vacuum switch or a vacuum pressure gauge can be selected. Solenoid valve for operating cylinder, etc. + vacuum ejector Prevents problems related to vacuum circuits or airborne contaminants. Maximum flow rate 200 l/min (ANR). The collected dust does not remain in the case. Prevents problems related to vacuum circuits or airborne contaminants. Maximum flow rate l/min (ANR) (metric size) The pipe tubing can be mounted and removed by one-touch operation. A variety of models (with or without a buffer), pad shapes (flat, flat with ribs, deep, bellows), pad diameters (ø2 to ø20) ø and above on special order In the rectangular, compact cylinder CU series with a high level of mounting precision, a vacuum passage is provided in the rod to facilitate the mounting of a vacuum pad and to save space. Digital pressure switch/zse Diaphragm type pressure switch/zsm1 Adsorption confirmation switch for small diameter/zsp1 Refer to Best Pneumatics 2004 ol. 1 catalog. Adsorption Transfer System by acuum Pump Equipment (acuum switch valve / acuum release valve / Restrictor / acuum pressure switch / Filter) that is needed for controlling the vacuum pressure has been integrated to achieve efficient assembly work and a compact design. Pressure gauge for vacuum Series GZ acuum pump Compressor Air filter Series AF Refrigerated air dryer Series IDF Front matter 1 Mist separator Series AM If the control unit is not used, it is possible to configure the system by using individual units such as a switch valve, vacuum release valve, filter, pressure switch, etc. Regulator Series AR acuum regulator or Electro-pneumatic regulator acuum regulator/series IR Direct operated vacuum regulator that regulates vacuum pressure Electro-pneumatic regulator/ Series IT209 Controls the vacuum pressure in acuum pad/series ZP accordance with external electric signals Control unit/zq00 ZX0 ZR0 Workpiece Free mount cylinder for vacuum Series ZCUK

Single Unit System Equipment such as an ejector is configured as an individual unit. Thus, it is possible to create a flexible system configuration in which the circuit composition and the mounting locations can be selected as desired. Ejector module/circuit diagram Supply valve Pressure switch for vacuum Filter Ejector unit Pad side acuum release valve Restrictor for vacuum release flow adjustment Supply valve Controls compressed air to ejector. Ejector unit Series ZH One-touch fitting acuum release valve Controls compressed air that is used for ejecting the workpiece. Restrictor (Flow control valve) Pressure gauge for vacuum Series GZ Air suction filter Series ZF Removes dust that is present in air that has been drawn in. acuum pressure switch Series ZS Pressure Detects the vacuum pressure gauge for and verifies the adsorption. vacuum Series GZ Other equipment for vacuum system Other Equipment Description acuum regulator/electronic vacuum regulator/directional control equipment/pressure gauge for vacuum/ Fittings & Tubing/Flow control equipment/acuum accessory equipment acuum pad/series ZP Free mount cylinder for vacuum Series ZCUK Related products Air filter/regulator/ Filter regulator/ Mist separator Workpiece Control unit/circuit diagram acuum release valve Filter Pad side Control unit acuum pump acuum switch valve Pressure switch for vacuum acuum Pump System Equipment Control unit Series ZQ00 Series ZX0 Series ZR0 Description acuum regulator IR Electro-pneumatic regulator IT209 Ejector System Equipment Applications Width mm Weight 9 g (Single unit with vacuum pressure switch and suction filter) Effective area of vacuum switch valve is 3 mm 2. Necessary functions can be combined through modular design. Double solenoids provide a self-holding function. Effective area of vacuum switch valve is 8.2 mm 2. Necessary functions can be combined through modular design. Other Equipment Applications Direct operated vacuum pressure adjustment valve that regulates the vacuum pressure. Controls the vacuum pressure in accordance with external electric signals. acuum switch valve Equipment acuum release valve acuum pressure switch Filter Refer to Best Pneumatics 2004 ol. 13 catalog for the detailed acuum Pump System Equipment and Related Products. Front matter 2

acuum Equipment Model Selection When an ejector and a vacuum pump are used for picking up a workpiece, the response times for picking up (and discharging), as well as the vacuum pressures during adsorption, vary according to the piping condition and the type of workpiece. Thus, by selecting the proper vacuum equipment, effective utilization of the vacuum system can be achieved. Selection Step 1. Pad selection 1-A Theoretical lifting force 1-B Calculation method: Pad diameter acuum Equipment Model Selection 2. Ejector / acuum switch valve selection 2-A Calculation method: Adsorption response time 2-B eakage during workpiece adsorption 2-C Size of ejector and vacuum supply valve (with leakage) 2-D Size of ejector and vacuum supply valve (without leakage) Selection Step 1 Pad Selection The pad diameter is found by means of a pad lift calculation. The calculated value should be used for reference and confirmed by actual adsorption tests when necessary. In the lift calculation, consideration should be given to the weight of the workpiece, forces due to acceleration during movement (lifting, stopping, turning, etc.) and a sufficient safety margin should be allowed. An additional margin should also be allowed when determining the number and arrangement of pads. 1-A Theoretical ifting Force The theoretical lifting force of a pad can be found by calculation or from the theoretical lifting force table (1) shown below. Calculation W = P x S x 0.1 x 1 t W: ifting force (N) P : acuum pressure (kpa) S : Pad area (cm 2 ) t : Safety factor Horizontal lifting: 4 or more ertical lifting: 8 or more Horizontal lifting ertical lifting Theoretical ifting Force The theoretical lifting force (not including the safety factor) is found from the pad diameter and vacuum pressure. The required lifting force is then found by dividing the theoretical lifting force by the safety factor. Pad ifting force = Theoretical lifting force t This type of application should basically be avoided. (1) Theoretical ifting Force (Theoretical lifting force = P x S x 0.1) Unit: N Pad size (mm) 2 x 4 3. x 7 4 x ø2 ø4 ø ø8 ø ø13 ø1 ø20 ø2 ø32 ø40 ø0 Pad area (cm 2 ) 8 80 7 0.07 0.0 0. 0.3 0.21 1.78 1.8 1.7 0.3 3.0 2.88 2.70 0.031 0.24 0.248 0.233 0.12 1.07 1.01 0.94 0.283 2.41 2.2 2.12 0.03 4.28 4.02 3.77 0.78.7.28.89 1.33 11.3. 9.98 2.01 17.1 1.1 1.1 3.14 2.7 2.1 23. 4.91 41.7 39.3 3.8 8.04 8.3 4.3 0.3 12. 7 1 94. 19. 17 17 147 70 0.49 1.47 2.2 0.217 0.882 1.98 3.2.0 9.31 14.1 22.0 34.4.3 88.2 137 acuum 0.4 1.3 2.34 0.202 0.819 1.84 3.27. 8. 13.1 20.4 31.9 2.3 81.9 127 pressure (kpa) 0 0.42 1.2 2.1 0.18 0.7 1.70 3.02 4.71 7.98 12.1 18.8 29. 48.2 7. 118 0 4 40 0.39 0.3 0.32 0.28 1.1 1.0 0.94 0.84 1.98 1.80 1.2 1.44 0.171 0.1 0.140 0.124 0.93 0.30 0.7 0.04 1. 1.42 1.27 1.13 2.77 2.2 2.2 2.01 4.32 3.93 3.3 3.14 7.32..99.32 11.1.1 9.0 8.04 17.3 1.7 14.1 12. 27.0 24. 22.1 19. 44.2 40.2 3.2 32.2 9.3 3.0.7 0.4 8 98.0 88.2 78.4 1

acuum Equipment Model Selection Selection Step 1 Pad Selection 1-B Finding the Pad Diameter A pad diameter which accounts for a safety factor based upon the workpiece lifting method (horizontal or vertical), can be selected by using the calculation formula or the selection graphs (Below graphs (1) and (2)). Calculation D = 4 x 1 x x t x 00 3.14 P W n D : Pad diameter (mm) n : Number of pads per workpiece W: ifting force (N) P : acuum pressure (kpa) t : Safety factor Horizontal lifting: 4 or more ertical lifting: 8 or more Selection Graph After establishing the workpiece weight, number of pads to be used, and the vacuum pressure when adsorbing the workpiece, the pad diameters for horizontal lifting and vertical lifting can be found by means of using graphs (1) and (2). Selection Graph (1)-1 Pad Diameter Selection Graph by ifting Force Horizontal ifting (ø2 to ø0) Pad diameter (mm) 0 40 32 2 20 1 13 8 4-80 kpa -70 kpa -0 kpa -0 kpa -40 kpa Selection Graph (2)-1 Pad Diameter Selection Graph by ifting Force ertical ifting (ø2 to ø0) Pad diameter (mm) 0 40 32 2 20 1 13 8 4-80 kpa -70 kpa -0 kpa -0 kpa -40 kpa 2 2 0.01 0.0 0.1 0. 1 0 0.01 0.0 0.1 0. 1 0 ifting force (N) ifting force (N) Selection Graph (1)-2 Pad Diameter Selection Graph by ifting Force Horizontal ifting (ø0 to ø20) Selection Graph (2)-2 Pad Diameter Selection Graph by ifting Force ertical ifting (ø0 to ø20) Pad diameter (mm) 20 200 10 12 0 80 3 0-80 kpa -70 kpa -0 kpa -0 kpa -40 kpa Pad diameter (mm) 20 200 10 12 0 80 3 0-80 kpa -70 kpa -0 kpa -0 kpa -40 kpa 0 0 00 00 0 0 00 ifting force (N) ifting force (N) How to read the graph Example: Workpiece weight 1 kg (ifting force: 9.8 N) : Conditions/Number of pads: pcs. acuum pressure 0 kpa Horizontal lifting <Selection procedure> From the conditions at the left, the lifting force per pad: 9.8 N pcs. = 2 N, and for horizontal lifting, selection is made from graph (1)-1. Then, extending the intersection point of the lifting force 2 N and with a vacuum pressure of 0 kpa to the left, a pad diameter of 13 mm is obtained. Therefore, a pad diameter of 13 mm or greater should be selected. 2

acuum Equipment Model Selection Selection Step 2 Selection of Ejector and acuum Switch alve 2-A Adsorption Response Time When a pad is used for the adsorption transport of a workpiece, the approximate adsorption response time can be obtained (the length of time it takes for the pad s internal vacuum pressure to reach the pressure that is required for adsorption after the supply valve {vacuum switch valve} has been operated). An approximate adsorption response time can be obtained through formulas and selection graphs (3) and (4). acuum System Circuit Diagram Supply valve Switch valve Selection Graph 1. Tubing piping capacity Piping capacity from ejector and switch valve at vacuum pump to pad can be found from selection graph (3). Selection Graph (3) Tubing I.D. Piping Capacity Workpiece Pad Workpiece acuum Pressure and Response Time after Supply alve (switch valve) is Operated. Supply valve (Switch valve) operation Pad Piping capacity (l) Tubing I.D. acuum pressure (P) Tubing length (m) How to read the graph Example: For obtaining the volume of tubing I.D. ø mm and 1 meter length. Arrival time (sec) Pv: ast vacuum pressure T1 : Arrival time to 3% of last vacuum pressure Pv T2 : Arrival time to 9% of last vacuum pressure Pv Calculation Adsorption response times T1 and T2 can be obtained through the formulas given below. T1 : Arrival time to 3% of last vacuum pressure Pv (sec) Adsorption response time T1 T2 : Arrival time to 9% of last = x 0 vacuum pressure Pv (sec) Q D : Piping diameter (mm) Adsorption response time : ength from ejector and switch T2 valve to pad (m) = 3 x T1 : Piping capacity from ejector and Piping capacity switch valve to pad (l) Q : Smaller one between the Q1 and Q2 = 3.14 D 2 x x 1 (l) l/min (ANR) 4 00 Q1: Average suction flow (l/min (ANR)) 3 Calculation of average suction flow Ejector Q1 = (1/2 to 1/3) x Ejector Max. suction flow l/min (ANR) acuum pump Q1 = (1/2 to 1/3) x 11.1 x Effective area of vacuum pump (mm 2 ) Q2: Max. flow from ejector and switch valve to pad by piping system Q2 = S x 11.1 l/min (ANR) S : Effective area of piping (mm 2 ) By extending leftward from the point at which the 1 meter tubing length on the horizontal axis intersects the line for a tubing I.D. ø mm, the piping volume approximately equivalent to 0.02 l can be obtained, on the vertical axis. Piping capacity 0.02 l 2. Effective area of tubing Effective area of tubing from graph below Equivalent effective area (mm 2 ) Selection Procedure How to read the graph Example: Tubing size ø8/ø, 1 m Selection Procedure Tubing I.D. Tubing length (m) From the point of intersection of tubing length 1 m of lateral axis and tubing I.D. ø mm, the equivalent effective area at vertical axis can be found as approx. 18 mm 2. Equivalent effective area 18 mm 2

acuum Equipment Model Selection Selection Step 2 Selection of Ejector and acuum Switch alve 2-A Adsorption Response Time Selection Graph 3. Obtaining the adsorption response times By operating the supply valve (switch valve) that controls the ejector (vacuum pump), the adsorption response times T1 and T2 that elapsed before the prescribed vacuum pressure is reached can be obtained using the selection graph (4). Selection Graph (4) (Adsorption Response Time) 2-B eakage during Workpiece Adsorption eakage Even if the pad picks up a workpiece, air could be drawn in depending on the type of the workpiece. As a result, the vacuum pressure in the pad becomes reduced and the amount of vacuum that is necessary for adsorption cannot be attained. When this type of workpiece must be handled, it is necessary to select the proper size of the ejector and the vacuum switch valve by taking into consideration the amount of air that could leak through the workpiece. Pad Pad alve effective area = Q/11.1 (mm 2 ) Max. suction flow Q (l/min (ANR)) Piping capacity Arrival time of vacuum pressure (3%) T1 (sec) entilation workpiece Rough-surfaced workpiece eakage from Effective Area of Workpiece eakage Q = 11.1 x S Q: eakage (l/min (ANR)) S: Effective area between a workpiece and a pad, and the workpiece opening area (mm 2 ) eakage from Adsorption Test As described in the illustration below, pick up a workpiece using an ejector, pad and vacuum gauge. At this time, read the vacuum pressure P1, and obtain the suction flow using flow characteristics graph for the ejector that is being used, and render this amount as the leakage of the workpiece. How to read the graph Example 1: For obtaining the adsorption response time until the pressure in the piping system with a piping volume of 0.02 l is discharged to 3% (T1) of the final vacuum pressure through the use of the vacuum ejector ZH07S with a maximum suction flow of 12 l/min (ANR). Selection Procedure Arrival time of vacuum pressure (9%) T2 (sec) Conversely, the size of the ejector or the size of the switch valve of the vacuum pump system can be obtained from the adsorption response time. From the point at which the vacuum ejector s maximum suction flow of 12 l/min (ANR) and the piping volume of 0.02 l intersection, the adsorption response time T1 that elapses until 3% of the maximum vacuum pressure is reached can be obtained. (Sequence in selection graph (4), A B) T1 0.3 seconds. Example 2: For obtaining the discharge response time until the internal pressure in the l tank is discharged to 9% (T2) of the final vacuum pressure through the use of a valve with an effective area of 18 mm 2. Selection Procedure From the point at which the valve s effective area of 18 mm 2 and the piping volume of l intersection, the discharge response time (T2) that elapses until 9% of the final vacuum pressure is reached can be obtained. (Sequence in selection graph (4), C D) T2 12 seconds. acuum pressure (kpa) 93 80 7 3 40 27 13 acuum pressure Air consumption Suction flow 0 0.1 0.2 0.3 0.4 0. 0. Supply pressure (MPa) acuum pressure: P1 Pad 20 0 Workpiece Exercise: Using a supply pressure of 0.4 MPa, when the ejector (ZH07) picks up a workpiece that leaks air, the vacuum gauge indicated a pressure of 3 kpa. Calculate the leakage volume from the workpiece. Selection Procedure When the suction flow at 3 kpa is obtained using the ZH07DS flow characteristics graph, the leakage volume is l/min (ANR). (A B C) eakage Suction flow l/min (ANR) ZH07S Exhaust Characteristics Suction flow (l/min (ANR)) Air consumption (l/min (ANR)) Flow Characteristics Supply pressure {0.4 MPa} acuum pressure (kpa) 93 80 7 3 40 27 13 A B C 0 1 Suction flow (l/min (ANR)) 4

acuum Equipment Model Selection Selection Step 2 Selection of Ejector and acuum Switch alve 2-C Sizing Ejector and acuum Switch alve (with eakage) If there is leakage through a workpiece, the necessary size of the ejector and the vacuum switch valve can be obtained by adding the leakage volume to the maximum suction flow. Calculation 1. Average suction flow to achieve adsorption response time Q = x 0 + Q T2 = 3 x T1 Q : Average suction flow l/min (ANR) : Piping capacity (l) T1 : Arrival time to stable Pv 3% after adsorption (sec) T2 : Arrival time to stable Pv 9% after adsorption (sec) Q : eakage during workpiece adsorption l/min (ANR) 2. Max. suction flow Qmax = (2 to 3) x Q l/min (ANR) Selection Procedure Ejector Select the ejector with the greater maximum suction flow from the Qmax. given above. Direct-operated switch valve Qmax Effective area S = (mm 2 ) 11.1 Select a valve (solenoid valve) having an effective area that is greater than that of the effective area formula given above from the related equipment ( SMC Best Pneumatics 2004 ol. 13 catalog). Selection Graph T1 1. Tubing capacity Using selection graph (3) (page 3) Tubing I.D. Piping Capacity, obtain the tubing capacity. 2. Max. suction flow Qmax Using selection graph (4) (page 4) Adsorption Response Time, obtain the maximum suction flow Q that does not contain the leakage amount Q, based on the set adsorption response times (T1, T2) and the tubing volume. Max. suction flow Qmax = Q + (3 x Q) Q : Max. suction flow from selection graph (4) Adsorption Response Time on page 4 Q: eakage volume l/min (ANR) (page 4) (2) B from leakage when adsorbing up a workpiece Selection Procedure Ejector Select an ejector having a greater maximum suction flow than that of Qmax given above. During the selection, verify the pad s lift force because the vacuum pressure after adsorption will be lower than the maxi- Flow Characteristics mum vacuum pressure due to the 93 leakage volume Q l/min (ANR). 80 Example: ZHS (Supply pressure 0.4 MPa) If the leakage volume Q is 12 l/min (ANR), the vacuum pressure after adsorption will be 73 kpa. (A B) acuum pressure (kpa) 7 3 40 27 13 2-D Sizing Ejector and acuum Switch alve (without eakage) Calculation 1. Average suction flow T2 = 3 x T1 Q : Average suction flow l/min (ANR) : Piping capacity T1 : Arrival time to stable Pv 3% after adsorption (sec) T2 : Arrival time to stable Pv 9% after adsorption (sec) 2. Max. suction flow Qmax = (2 to 3) x Q l/min (ANR) Selection Procedure Ejector Select the ejector with the greater maximum suction flow from the Qmax. given above. acuum switch valve Qmax Effective area S = (mm 2 ) 11.1 Select a valve (solenoid valve) having an effective area that is greater than that of the effective area formula given above from the related equipment ( SMC Best Pneumatics 2004 ol. 13 catalog). Selection Graph 1. Tubing capacity Using tubing capacity selection graph (3) (page 3) Tubing I.D. Piping Capacity, obtain the tubing capacity. 2. Max. suction flow Qmax Using selection graph (4) (page 4) Adsorption Response Time, obtain the maximum suction flow Q based on the set adsorption response times (T1, T2) and the tubing volume. Selection Procedure Ejector Select an ejector having a greater maximum suction flow than that of Qmax. given above. acuum switch valve Using valve selection graph (4) (page 4), move the maximum suction flow Qmax point parallel to the graduation line of the effective area S of the left valve; then, obtain the effective area of the vacuum switch valve from the intersecting point. Ejector Q = x 0 Pad T1 Pad acuum source 0 20 30 40 Suction flow (l/min (ANR)) acuum switch valve Using selection graph (4) (page 4), move the maximum suction flow Qmax. point parallel to the graduation line of the effective area S of the left valve; then, obtain the effective area of the vacuum switch valve from the intersecting point.

acuum Equipment Model Selection Caution Caution on acuum Equipment Selection As a countermeasure for power outages, select a supply valve that is normally open or one that is equipped with a selfholding function. Select a vacuum switch valve that has an effective area that does not reduce the composite effective area consisting of the areas from the pad to the ejector. For the vacuum release valve, select a 2- or 3-port valve with a low vacuum specification. Also, use a needle valve to regulate the release flow rate. During the adsorption transport of a workpiece, verification of the vacuum switch is recommended. In addition, visually verify the vacuum gauge when handling a heavy or a hazardous item. The ZSP1 type is the optimal type for the adsorption/transport of small parts using a suction nozzle with a small diameter. Install a filter (ZFA/ZFB/ZFC series) before the pressure switch if the ambient air is of low quality. Use a suction filter (ZFA/ZFB/ZFC series) to protect the switch valve and to prevent the ejector from becoming clogged. Also a suction filter must be used with the ZQ series in a dusty environment. If only the unit s filter is used, it will become clogged quickly. Caution Caution on Matching with acuum Circuit Diagram Ejector and number of pads acuum pump and number of pads acuum line Tank acuum source Ideally, one pad should be used for each ejector. When more than one pad is attached to a single ejector, if one of the workpieces becomes detached, the vacuum pressure will drop, causing other workpieces to become detached. Therefore, the countermeasures listed below must be taken. Adjust the needle valve to minimize the pressure fluctuation between adsorption and non-adsorption operations. Provide a vacuum switch valve to each individual pad to minimize the influences on other pads if an adsorption error occurs. Ideally, one pad should be used for each ejector. When more than one pad is attached to a single vacuum line, take the countermeasures listed below. Adjust the needle valve to minimize the pressure fluctuation between adsorption and non-adsorption operation. Include a tank and a vacuum pressure reduction valve (vacuum pressure regulator valve) to stabilize the source pressure. Provide a vacuum switch valve to each individual pad to minimize the influences on other pads if an adsorption error occurs.

acuum Equipment Model Selection Caution Caution on Ejector Nozzle Diameter Selection acuum pressure eakage If a considerable amount of leakage occurs between the workpiece and the pad, resulting in incomplete adsorption, or to shorten the adsorption transport time, select an ejector nozzle with a larger diameter from the ZH/ZM/ZR/Z/ZQ series. Caution on Pad Selection Set the operating pressure below the pressure that has been stabilized after adsorption and determine the pad diameter in accordance with the operating pressure. During the selection of a pad, keep in mind that the vacuum pressure during the adsorption of a workpiece that leaks becomes lower than the maximum vacuum pressure. Caution on acuum ine Equipment Selection Determine the volume of the suction filter and the effective area of the switching valve in accordance with the maximum suction flow of the ejector and the vacuum pump. Make sure that the effective area is greater than the value that has been obtained through the formula given below. (If the devices are connected in series in the vacuum line, their effective areas must be combined.) S = Qmax/11.1 S: Effective area (mm 2 ) Qmax: Max. suction flow l/min (ANR) acuum Switch (Series ZS), acuum Gauge (Series GZ) When adsorbing and transporting a workpiece, verify at the vacuum switch as much as possible (In addition, visually verify the vacuum gauge, especially when handling a heavy or a hazardous item.). When picking an electronic part or a small precision part, if the suction nozzle is approximately ø1, the difference in pressure between ON and OFF becomes small (although this will also depend on the capacity of the ejector and the vacuum pump). In such a case, it will be necessary to use the suction verification switch ZSP1, which has a small hysteresis and high precision. Conversely, it cannot be detected by an ejector with a large suction capacity. Therefore, use the ejector with appropriate suction flow. Furthermore, it will become necessary to stabilize the pressure of the ejector and the vacuum pump. Suction Filter (Series ZFA/ZFB/ZFC) To protect the switching valve and the ejector from becoming clogged, a suction filter in the vacuum circuit is recommended. When using the ZQ series in a dusty environment, the unit s filter will become clogged quickly, so it is recommended that the ZFA/ZFB/ZFC series be used concurrently. 7

acuum Equipment Model Selection Safety Because suction is applied to an object during a vacuum adsorption transport, there is a possibility of dropping the object depending on the conditions. Thus, everything should be designed with safety as the number one priority in order to achieve a system design with an excellent margin of safety. Mounting Position As a rule, the unit must be installed horizontally. Although a diagonal or a vertical installation should be avoided whenever possible, if the unit must be installed in such a manner, be certain to guarantee absolute safety. Pad Horizontal lifting Impact to Pad ertical lifting When pushing a pad to a workpiece, make sure not to apply an impact or a large force which would lead to premature deformation, cracking, or wearing of the pad. Therefore, the pad should be pushed against the workpiece to the extent that its skirt portion deforms or that its ribbed portion comes into slight contact with the workpiece. Especially, when using a smaller diameter pad, make sure to locate it correctly. Decide the position not to strike Balance of Pad and Workpiece Make sure that the pad s suction surface is not larger than the surface of the workpiece to prevent vacuum leakage and unstable picking. Pad Caution Guide for drop prevention If multiple pads are used for transporting a flat object with a large surface area, properly allocate the pads to maintain balance. Also make sure that the pads are aligned properly to prevent them from becoming disengaged along the edges. Pad Caution Guide for drop prevention Provide an auxiliary device (example: a guide for preventing the workpieces from dropping) as necessary. acuum Pad Applications ifting Force, Moment, Horizontal Force To lift a workpiece vertically, make sure to take into consideration the acceleration rate, wind pressure, impact, etc., in addition to the weight of the workpiece. (Refer to Fig. 1) Because the pads are susceptible to moments, mount the pad so as not to allow the workpiece to create a moment. (Refer to Fig. 2) When a workpiece that is suspended horizontally is moved laterally, the workpiece could shift depending on the extent of the acceleration rate or the size of the friction coefficient between the pad and the workpiece. Therefore, the acceleration rate of the lateral movement must be minimized. (Refer to Fig. 3) Fig. 1 Fig. 2 Fig. 3 oading by acceleration and wind pressure lifting ifting direction Pad Pad positioning Pad Pay attention to the frictional force between pad and workpiece. Unsteady Distance between Pad and Workpiece If the pad and the workpiece cannot be positioned properly, such as when picking a workpiece having an uneven height, use a built-in spring type pad with a buffer. This type of pad acts as a cushion between the pad and the workpiece. If it is necessary to further position the pad and the workpiece, use a non-rotating buffer. Pad Pad Pad Pad Porous Workpiece To pick a permeable workpiece such as paper, select a pad with a small diameter that is sufficient to lift the workpiece. Because a large amount of air leakage could reduce the pad s suction force, it may be necessary to increase the capacity of the vacuum pump or enlarge the effective area of the piping passage. Flat Plate Workpiece When a workpiece with a large surface area such as sheet glass or PCB is suspended, the workpiece could move in a wavelike motion if a large force is applied by wind pressure or by an impact. Therefore, it is necessary to ensure the proper allocation and size of pads. Pad Form Selection by Workpiece To use an appropriate pad, select the shape of the pad in accordance with the shape and the material of the workpiece. Flat For a workpiece that has a flat surface and free of deformation. Flat with ribs For a workpiece that is susceptible to deformation. Deep For a workpiece with a curved surface. Porous workpiece Sheet glass, circuit board, etc. Bellows For a workpiece that does not have a space for a buffer, or for a workpiece with a diagonal surface. Soft Workpiece Pad Pad Pad Pad If a soft workpiece such as vinyl, paper, or thin sheet is picked up, the vacuum pressure could cause the workpiece to deform or wrinkle. In such a case, it will be necessary to use a small pad or a ribbed pad and reduce the vacuum pressure. Pad inyl, paper, etc. 8

acuum Equipment Model Selection acuum Pad: Workpiece Transfer Examples Materials NBR Material Silicon rubber Urethane rubber Fluoro rubber Conductive NBR Conductive silicon rubber Pads Flat Flat with ribs Deep Bellows Elliptic Pad form Ball joint type ong stroke buffer arge size buffer Conductive pad Applications Transport of general workpiece, Cardboard, eneer plate, Iron plate and others Semiconductor, Removing from die-casting, Thin workpiece Cardboard, Iron plate, eneer plate Chemical workpiece General workpiece of semiconductor (Static electricity resistance) Semiconductor (Static electricity resistance) Applications For when adsorption surface of a workpiece is flat and not deformed. For when a workpiece is likely to deform or in the case of releasing a workpiece certainly. For when a workpiece is spherical shape. For when there is not enough space to install a buffer or adsorption surface of a workpiece is slanted. For when a workpiece has limited adsorption surface or length is long and a workpiece is required to locate precisely. For when adsorption surface of a workpiece is not horizontal. For when a workpiece height is not even or cushioning toward a workpiece is required. For when a workpiece is heavy weight. As one of the countermeasures against static electricity, rubber material with reduced resistance is used. For antistatic measures Glossary Terms (Max.) suction flow Maximum vacuum pressure Air consumption Standard supply pressure Exhaust characteristics Flow characteristics acuum pressure switch Adsorption verification switch (Air) supply valve (acuum) release valve Flow adjustment valve Release pressure Pilot pressure External release acuum port Exhaust port Supply port Back pressure eakage Response speed Average suction flow Conductive pad acuum pressure (acuum) ejector Suction filter Description olume of air taken in by the ejector. The maximum volume is the flow rate of the air that is taken in without having anything connected to the vacuum port. The maximum value of the vacuum pressure that is generated by the ejector. The volume of compressed air that is consumed by the ejector. The optimal supply pressure for operating the ejector. The relationship between the vacuum pressure and the suction flow when the supply pressure to the ejector has been changed. The relationship between the vacuum pressure and the suction flow with the standard supply pressure supplied to the ejector. The pressure switch that is used for verifying the adsorption of a workpiece. The switch, based on an air pressure bridge, that is used for verifying the adsorption of a workpiece. It is used when the adsorption pad and the nozzle are extremely small. The valve that supplies compressed air to the ejector. The valve that supplied positive pressure or air to break the vacuum state of the adsorption pad. The valve that supplied positive pressure or air that regulates the flow of the air to break the vacuum. Pressure that is used for breaking the vacuum. Pressure that is used for operating the ejector valve. The action of breaking the vacuum using externally supplied air instead of using the ejector unit. Port for generating vacuum. Port for exhausting the air, which was used by the ejector, and the air taken in by vacuum port. Port for supplying the air, which is used by the ejector. Pressure inside the exhaust port. The entry of air into the vacuum passage, such as from an area between a workpiece and a pad, or between a joint and tubing. The vacuum pressure decreases when leakage occurs. The length of time that elapses from when the supply valve or the switching valve is activated until the pressure switch turns ON. It is also called the adsorption response time. The suction flow of the ejector or the pump, which is used for calculating the response speed. It is 1/2 to 1/3 of the maximum suction flow. A pad with a low electrical resistance that is used as an electrostatic prevention measure. Any pressure below the atmospheric pressure. When the atmospheric pressure is used as a reference, the pressure is presented by kpa (G), and when the absolute pressure is used as a reference, the pressure is represented by kpa {abs}. When referencing a piece of vacuum equipment such as an ejector, the pressure is generally represented by kpa. A device that generates vacuum by means of discharging the compressed air from a nozzle at a high speed, thus utilizing the phenomenon in which the pressure is reduced when the air around the nozzle is sucked. The vacuum filter that is provided in the vacuum passage in order to prevent the intrusion of dust into the ejector, the vacuum pump, or peripheral equipment. 9

acuum Equipment Model Selection Effective Diameter of acuum Pad Effective diameter at adsorption is as follows. acuum Area Diameter (acuum pressure: 84 kpa) after acuum Adsorption by acuum Pad Part no. ZP2004 ZP307 ZP40 ZP02 ZP04 ZP0 ZP08 ZP ZP13 ZP1 ZP20 ZP2 ZP32 ZP40 ZP0 ZP3 ZP80 ZP0 ZP12 Type Material Nominal size 2004 307 40 2 4 8 13 1 20 2 32 40 0 3 80 0 12 Flat U Silicon NBR rubber 2 x 4 3. x 7 4 x ø2 ø4 ø ø7 ø ø11 ø ø14 ø14 ø13 ø20 ø18 2 x 4 3. x 7 4 x ø2 ø4 ø4 ø7 ø9 ø11 ø9 ø12 ø13 ø11 ø17 ø17 Flat with ribs C Silicon NBR rubber ø ø11 ø13 ø1 ø18 ø21 ø2 ø33 ø9 ø11 ø13 ø14 ø17 ø20 ø24 ø30 Bellows B Silicon NBR rubber ø ø7 ø8 ø8 ø ø13 ø1 ø20 ø2 ø3 ø ø ø7 ø9 ø9 ø13 ø1 ø19 ø2 ø33 Deep D Silicon NBR rubber ø ø14 ø19 ø24 ø ø12 ø1 ø24 Heavy-duty H Silicon NBR rubber ø33 ø42 ø49 ø0 ø78 ø2 ø32 ø42 ø49 ø0 ø78 ø1 (mm) Heavy-duty bellows HB Silicon NBR rubber ø29 ø39 ø4 ø7 ø9 ø92 ø27 ø3 ø4 ø ø71 ø91 Proposals for Using the acuum Equipment Please consider the following items in order to enable the vacuum ejector and the vacuum pump system to operate more effectively. Graph 1 shows the timing of a typical operational pattern. The responsiveness can be increased depending on the condition. 1. Timing for generating vacuum The timing for opening/closing the valve will be counted if a vacuum is generated after the adsorption pad descends to absorb a workpiece. Also, there is a timing delay risk for the generating vacuum since the operational pattern for the verification switch, which is used for detecting the descending adsorption pad, is not even. To solve this issue, we recommend that vacuum be generated in advance, before the adsorption pad begins to descend to the workpiece. Adopt this method after confirming that there will be no misalignment resulting from the workpiece s light weight. 2. Adsorption verification In the case of lifting the adsorption pad after absorbing a workpiece, confirm that there is a suction verification signal from the vacuum switch, before the adsorption pad is lifted. If the adsorption pad is lifted, based on the timing of a timer, etc., there is a risk that the workpiece may be left behind. In general pick and place applications, the time for absorbing a workpiece is slightly different since the position of the adsorption pad and the workpiece are different after every operation. Therefore, program a sequence in which the suction completion is verified by a vacuum switch, etc. before moving to the next operation. 3. Supply pressure 3.1 Use the vacuum ejector with the standard supply pressure. When the product is supplied with the standard pressure, the maximum vacuum pressure and the maximum suction flow are performed, resulting in the improved response time for adsorption. Using a standard supply pressure is also the most effective way to save energy If an excessive supply pressure is used, the ejector peformance is reduced. Do not use the product with more than the standard supply pressure. 3.2 Excessive supply line pressure may occur when the operation is suspended (holidays, night time, etc.). Please use a separate regulator to gain sufficient flow in the upstream side of the ejector supply pressure pipings. 4. Set pressure for the vacuum pressure switch Set the optimum value after calculating the required vacuum pressure for lifting a workpiece. If a higher pressure than required is set, there is a possibility of being unable to confirm the suction even though the workpiece is absorbed. This will result in a suction error. When the tact time is emphasized, you should set using a lower pressure, with which a workpiece can be adsorped, only after considering the acceleration or vibration when a workpiece is transfered.. Equipment with vacuum equipment Carefully perform a debugging operation beforehand in equipment having vacuum products such as a handler, chip mounter, etc. Before actually using the equipment, carefully confirm the operation and perform a trial run, etc. Cylinder UP Cylinder DOWN Cylinder switch Supply valve acuum release valve port vacuum pressure acuum pressure switch set value During adsorption By lowering the setting of the vacuum switch, the tact time can be shortened. During vacuum release acuum pressure switch Graph 1. Example of a typical operational pattern timing Atmospheric pressure acuum pressure at operation

Space Saving acuum Ejector Series ZQ How to Order Ejector Unit For Made to Order, refer to page 24. ZQ1 0 1U K1 D31 C q w e r t y u i o!0!1!2 q Nozzle nominal size w Exhaust type 0 07 ø0. ø0.7 ø1.0 1U 3M With silencer for single unit With silencer for manifold e Solenoid valve combination (Refer to Table (1).) r Pilot valve (Refer to Table (1).) t Solenoid valve rated voltage (Refer to Table (1).) Symbol K1 Note 1) K2 J1 Note 1) J2 Q1 Q2 N1 N2 Supply valve Normally closed Normally open Normally closed Normally open atching positive common atching positive common atching negative common atching negative common acuum release valve Normally closed Normally closed None None Normally closed None Normally closed None Note 1) In cases when K2 or J2 (supply valve normally open) is selected for the solenoid valve combination, when vacuum is stopped for long periods of time ( minutes or more), do not continue to energize the supply valve, and shut off the air supply. Y Standard (DC: 1 W) Note 2) DC low wattage type (0. W) Note 2) Avoid energizing the solenoid valve for long periods of time. (Refer to Design and Selection on Specific Product Precautions 1.) 1 2 3 4 0 AC (0/0Hz) 200 AC (0/0Hz) 1 AC (0/0Hz) 220 AC (0/0Hz) 24 DC 12 DC Table (1) Combination of Solenoid alve, Pilot alve and Power Supply oltage Solenoid valve Combination Pilot valve Applicable power supply voltage () combination no. symbol symbol 0 AC 200 AC 1 AC 220 AC 24 DC q w e r t y u i o!0 K1 K1 K2 J1 J1 J2 Q1 Q2 N1 N2 Y Y Combinations q to!0 in the above table are the only possible options. 12 DC 11

Space Saving acuum Ejector Series ZQ y Electrical entry Note 3) u Manual override O -type plug connector, with 0.3 m lead wire, with light/surge voltage suppressor -type plug connector, without connector, with light/surge voltage suppressor Non-locking push type atching type: Push-locking type B ocking type (Q1/Q2/N1/N2: Not applicable) Note 3) atching type supply valve: Available in only. In this case, the supply valve and vacuum release valve come with a lock. G Grommet, with 0.3 m lead wire (atching/ac type: Not applicable) Note 4) i acuum pressure switch suction filter o acuum switch electrical entry F D31 D32 D1 D2 With suction filter only 1 NPN output + Analog output, with suction filter, Pressure range 0 to 0 kpa 2 NPN outputs, with suction filter, Pressure range 0 to 0 kpa 1 PNP output + Analog output, with suction filter, Pressure range 0 to 0 kpa 2 PNP outputs, with suction filter, Pressure range 0 to 0 kpa C C CN Connector type, with 0. m lead wire Connector type, with 3 m lead wire Connector type, without connector Note 4) The filter included in this product is of an simple type, and will become clogged quickly in environments with high quantities of dust or particulates. Please make additional use of an air suction filter of the ZFA, ZFB or ZFC series. Warning The filter case of this suction filter is made of nylon. Contact with alcohol or similar chemicals may cause it to be damaged. Also, do not use the filter when these chemicals are present in the atmosphere. Note )!0 Check valve Note )!1 Fitting ( port) Note, 7)!2 Fitting (P port) None K With check valve Note ) The check valve has a function to prevent the exhaust air from the silencer overflowing to the vacuum port side when a manifold is used. However, depending on usage conditions, it does not always suppress air overflow to the desired extent. During usage, please inspect thoroughly with actual machine. Also, in order to completely prevent the overflow of exhaust air, leave plenty of space between the check valve unit and adjacent ejector to avoid interference from the ejector s exhaust unit. Symbol 0 1 2 3 4 Applicable tubing O.D. Without fitting (M x 0.8) ø3.2 (Straight) ø4 (Straight) ø (Straight) ø3.2 (Elbow) ø4 (Elbow) Part no. KJS23-M KJS04-M KJS0-M KJ23-M KJ04-M Note ) When neither port fitting nor P port fitting are needed, enter nothing or 00 in the dotted line above How to Order. Symbol Applicable tubing O.D. 0 Without fitting (M x 0.8) 2 ø4 (Straight) 3 ø (Straight) ø4 (Elbow) Note 7) Manifold type: Not applicable Part no. KJS04-M KJS0-M KJ04-M Warning q Cannot be used for vacuum retention. w Use a release valve. (Without a release valve, a workpiece may not be released.) 12

S1 S1 S1 S1 S1 S1 S1 S1 Series ZQ Number of stations Note) 01 1 station 02 2 stations 08 Manifold 8 stations Note) Number of stations varies according to nozzle nominal size during simultaneous operation. Maximum Number of Stations in Simultaneous Operation Nozzle nominal size ø0. ø0.7 ø1.0 Maximum number of stations in simultaneous operation 8 stations stations 4 stations How to Order Flow/Exhaust Characteristics ZZQ1 07 B S C Supply port (P port) position B Both sides S Exhaust With silencers (Both sides) acuum release pressure supply port (PD port) None (Release pressure is B supplied from the P port.) Provided (Air can be C alternatively supplied from the P port.) Manifold Ordering Example ZZQ8-BSB 1 pc. ZQ3M-K1Y-D31C 4 pcs. (Stations 1 to 4) ZQ13M-K1Y-D31C 4 pcs. (Stations to 8) Note) The stations are sequentially numbered. When viewed from the side of the vacuum ports, the far left station is designated as station 1. eft acuum port H H kpa MODE SET1 SET2 H H ZQ3M-K1Y-D31C kpa MODE SET1 SET2 H H kpa MODE SET1 SET2 H H How to Read Flow Characteristics kpa MODE SET1 SET2 1 2 3 4 7 8 H H kpa MODE SET1 SET2 H H kpa MODE SET1 SET2 H H kpa MODE SET1 SET2 ZQ13M-K1Y-D31C H H kpa MODE SET1 SET2 Right ZQ / Exhaust Characteristics Maximum vacuum pressure (kpa) Maximum vacuum pressure (kpa) Maximum vacuum pressure (kpa) 80 0 40 20 80 0 40 20 80 0 40 20 Maximum vacuum pressure 0 0.1 0.2 0.3 0.4 0. Supply pressure (MPa) Maximum vacuum pressure 0 0.1 0.2 0.3 0.4 0. Supply pressure (MPa) 20 1 ZQ1 / Exhaust Characteristics Maximum vacuum pressure Air consumption Air consumption Maximum suction flow ZQ7 / Exhaust Characteristics 13 Air consumption Maximum suction flow Maximum suction flow 0 0.1 0.2 0.3 0.4 0. Supply pressure (MPa) 30 20 0 0 40 30 20 Maximum suction flow (l/min(anr)) Air consumption (l/min(anr)) Maximum suction flow (l/min(anr)) Air consumption (l/min(anr)) Maximum suction flow (l/min(anr)) Air consumption (l/min(anr)) ZQ / Flow Characteristics Maximum vacuum pressure (kpa) 80 0 40 20 0 2 4 8 Suction flow (l/min(anr)) ZQ7 / Flow Characteristics Maximum vacuum pressure (kpa) ZQ1 / Flow Characteristics Maximum vacuum pressure (kpa) 80 0 40 20 80 0 40 20 0 1 Suction flow (l/min(anr)) Supply pressure 0.3 MPa Supply pressure 0.43 MPa Supply pressure 0.43 MPa 0 1 20 2 Suction flow (l/min(anr)) acuum pressure Pmax P1 Q1 Suction flow Qmax Flow characteristics are expressed in ejector vacuum pressure and suction flow. If suction flow rate changes, a change in vacuum pressure will also be expressed. Normally this relationship is expressed in ejector standard use. In the graph, Pmax. is max. vacuum pressure and Qmax is max. suction flow. The valves are specified according to catalog use. Changes in vacuum pressure are expressed in the below order. 1. When ejector suction port is covered and made airtight, suction flow becomes 0 and vacuum pressure is at maximum value (Pmax). 2. When suction port is opened gradually, air can flow through, (air leakage), suction flow increases, but vacuum pressure decreases. (condition P1 and Q1) 3. When suction port is opened further, suction flow moves to maximum value (Qmax), but vacuum pressure is near 0. (atmospheric pressure). When vacuum port (vacuum piping) has no leakage, vacuum pressure becomes maximum, and vacuum pressure decreases as leakage increases. When leakage value is the same as max. suction flow, vacuum pressure is near 0. When ventirative or leaky work must be adsorbed, please note that vacuum pressure will not be high. Precautions Be sure to read this before handling. Refer to the back page 1 through to 2 for Safety Instructions and Common Precautions on the products mentioned this catalog. Caution Refer to page 1 through to for the product selection in the ZQ series and the sizing program.

Space Saving acuum Ejector Series ZQ Specifications Ejector Model Nozzle nominal diameter (mm) Maximum suction flow (l/min (ANR)) Air consumption (l/min (ANR)) Maximum vacuum pressure Supply pressure range Supply pressure Note) Operating temperature range ZQ 0. 14 Note) Maximum suction flow can be obtained by standard supply pressure. ZQ7 0.7 23 80 kpa 0.3 to 0. MPa (Normally open: 0.3 to 0.4 MPa) 0.3 MPa 0.4 MPa to 0 C ZQ1 1.0 22 4 Weight Single unit With suction filter Note 1) With switch and suction filter Note 2) 9 g 9 g End plate assembly for manifold 122 g Note 1) Including a 0.3 m connector for supply valve and vacuum release valve. Note 2) Including a 0.3 m connector for supply valve and vacuum release valve and a 0. m connector for switch. Calculation of weight for the manifold type (Single unit weight) x (Number of stations) + (Weight of end plate assembly for manifold) Example) Switch + 8 stations with suction filter 9 g x 8 + 122 g = 994 g Supply alve / acuum Release alve Model Refer to How to Order for ( solenoid valves on page 1. ) Fluid Maximum operating pressure Minimum operating pressure Ambient and fluid temperature ubrication Manual override Rated coil voltage Power consumption (current value) Electrical entry Type DC 0 AC 1 AC 200 AC 220 AC Normally closed Standard (1 W) ow wattage type (0. W) Q1-1 W 0. A ( ma) 0. A ( ma) 1.0 A ( ma) 1.1 A ( ma) Grommet Q1Y- Non-locking push type / ocking type (Tool type) 12, 24 DC, 0, 1, 200, 220 AC 12, 24 DC 0. W -type plug connector (with light/surge voltage suppressor) atching type Q1 N - 1 W Normally open ZQ1-Q120- Air / Inert gas 0. MPa 0.4 MPa 0.3 MPa to 0 C Not required Push-locking type 12, 24 DC, 0, 1, 200, 220 AC 0. A ( ma) 0. A (.9 m) 1.2 A ( ma) 1.3 A (.9 ma) -type plug connector with light/surge ( ) voltage suppressor Non-locking push type / ocking type (Tool type) 12, 24 DC Grommet -type plug connector with light/surge ( voltage suppressor ) 14

Series ZQ Specifications acuum Pressure Switch Model Refer to How to Order for vacuum ( pressure switches on page 1. ) Rated pressure range Set pressure range Withstand pressure Fluid Power supply voltage Current consumption Ambient temperature range Ambient humidity range Withstand voltage Insulation resistance Switch output Maximum load current Maximum applied voltage Residual voltage Response time Hysteresis Display Display accuracy Output indicator light Analog output Output voltage inearity ZQ1S-D31--AS 0 to 0 kpa 0 to 99 kpa 0.2 MPa Air / Non-corrosive/Non-combustible gas 12 to 24 DC ±% 3 ma or less [with power supply voltage of 24 DC and switch output ON (with no load)] to 0 C (with no freezing or condensation) 3 to 8 %RH in operation and saving (with no condensation) 00 AC for 1 min. 0 MΩ or more (between live parts and pressure port at 00 DC Mega) 1 NPN output + Analog output 1 PNP output + Analog output 2 NPN outputs 2 PNP outputs 80 ma (per output) 30 (for NPN output) NPN output: 0.8 or less (at 80 ma inrush), PNP output: 1.2 or less (at 80 ma discharge) 2 ms or less 0 to 1% F.S. or less (variable) 2% F.S. or less (fixed) 0 to 1% F.S. or less (variable) 2% F.S. or less (fixed) Illuminates when the output is turned ON. (Red ED) ZQ1S-D1--AS ZQ1S-D32--AS ZQ1S-D2--AS 2-digit Red ED ±3 %F.S. ±2 digits (Only applicable to D31 and D1) 1 to ±2.% F.S. or less ±0. F.S. or less Illuminates when the output is turned ON. (Red ED for OUT1 and Green ED for OUT2) Construction Single unit Manifold t e w q r y u i o Component Parts No. Description Material 1 2 3 4 Poppet valve assembly Nozzle Diffuser acuum release flow adjustment needle Aluminum alloy Aluminum alloy Aluminum alloy Replacement Parts No. Description Material Part no. 7 8 9 Solenoid valve Filter element Sound absorbing material 1 (single unit) acuum pressure switch Sound absorbing material 2 (manifold) PF PF PF Refer to page 1. XT34--001-AS ZQ-SAE Refer to page 17. ZZQ-SAE 1

Space Saving acuum Ejector Series ZQ How to Order Solenoid alve Actuation 1 Normally closed Q1 1 0 ZQ1-Q1 2 0 Actuation 2 Normally open Pilot valve Standard (1 W) Solenoid valve rated voltage 24 DC 12 DC Pilot valve Standard (1 W) ow wattage type (0. W) Y AC type: Not applicable atching positive common N atching negative common Solenoid valve rated voltage 1 0 AC (0/0Hz) 2 200 AC (0/0Hz) 3 1 AC (0/0Hz) 4 220 AC (0/0Hz) 24 DC 12 DC Manual override Note) Non-locking push type atching type: Push-locking type B ocking type Electrical entry Note) -type plug connector, with 0.3 m lead wire Connector assembly part no. Note) atching type: Available in only How to order connector assembly DC positive common Single AXT1-14A- atching AXT1-13A- DC negative common atching AXT1-13AN- 0 AC Single AXT1-31A- atching AXT1-32A- 200 AC Single AXT1-34A- atching AXT1-3A- Connector, socket (3 pcs) only AXT1-12A ead wire length 20 30 300 mm 00 mm 00 mm 2000 mm 3000 mm ead wire length of the plug connector The lead wire length for a valve with a lead wire is 300 mm. When in need of a valve with a lead wire longer than 00 mm, place an order for a valve without a connector and connector assembly. O -type plug connector, without connector G Grommet, with 0.3 m lead wire (atching/ac type: Not applicable) Note) Mounting screws are attached. 1

Series ZQ How to Order acuum Pressure Switch 31 32 1 2 C C CN ZQ1S-D 31 C Switch specifications 1 NPN output + Analog output, Pressure range 0 to 0 kpa 2 NPN outputs, Pressure range 0 to 0 kpa 1 PNP output + Analog output, Pressure range 0 to 0 kpa 2 PNP outputs, Pressure range 0 to 0 kpa Electrical entry Note) Connector type, with 0. m lead wire Connector type, with 3 m lead wire Connector type, without connector Note) Mounting screws are attached. How to Set acuum Pressure Switch How to set pressure Pressure trimmer selects the ON pressure. Clockwise rotation increases high vacuum set point. When setting, use a flat head screw driver which fits the slot in the trimmer, and turn it gently with your finger tips. (rotational torque: 0.02 N m or less) When using ZQ1S-D31/-D1-AS (a) Set display mode switch (MODE) to S. (b) Set the switch operating pressure by rotating the pressure setting trimmer (SET). (The set operating pressure value will be shown on the display.) (c) Set the hysteresis by rotating the hysteresis setting trimmer (HYS). (d) Return the display mode switch (MODE) to RUN. (The pressure value of the vacuum port will be shown on the display.) When using ZQ1S-D32/-D2-AS (a) Set display mode switch (MODE) to S1. (b) Set the Switch 1 operating pressure by rotating the pressure setting trimmer 1 (SET1). (The S1 set operating pressure value will be shown on the display.) (c) Set display mode switch (MODE) to S2. (d) Set the Switch 2 operating pressure by rotating the pressure setting trimmer 2 (SET2). (The S2 set operating pressure value will be shown on the display.) (e) Return the display mode switch (MODE) to RUN. (The pressure value of the vacuum port will be shown on the display.) 17 Hysteresis setting trimmer Pressure setting trimmer Display mode switch Pressure setting trimmer 2 Pressure setting trimmer 1 Display mode switch AS Check valve Note) None K With check valve Note) The check valve has a function to prevent the exhaust air from the silencer overflowing to the vacuum port side when a manifold is used, but it is incapable of completely preventing overflow. During usage, please inspect thoroughly with actual machine. Also, in order to completely prevent the overflow of exhaust air, leave plenty of space between the check valve unit and adjacent ejector to avoid interference from the ejector s exhaust unit. Warning q Cannot be used for vacuum retention. w Use a vacuum release valve. (Without a vacuum release valve, the workpiece may not be released.) Switch connector part no. C: ZS-20-A-X2 C: ZS-20-A-30-X2 Housing / Socket part no. ZS-20-A-X When using the switch to confirm correct adsorption, the set pressure should be as low as possible, but not so low that a false confirmation signal is given when adsorption is incomplete. Hysteresis Hysteresis is the actual pressure variance from set pressure occuring when the output signal turns from ON to OFF. The set pressure is the pressure selected to switch from OFF to ON mode. Internal Circuits and Wiring Examples ZQ1S-D31-AS Operating ED Switch main circuit 88 Pressure indication ZQ1S-D1-AS Sensor Sensor High vacuum Supply pressure Setting pressure Operating ED Switch main circuit 88 Atmospheric pressure Pressure indication High vacuum Setting pressure 0 Atmospheric pressure 0 High pressure Brown: Power supply Pressure oad Pressure Black: Switch output White: Analog output Blue: Common Brown: Power supply White: Analog output Black: Switch output oad Blue: Common ZQ1S-D32-AS ZQ1S-D2-AS Pressure Pressure Hysteresis Sensor Sensor Reliable adsorption Unstable adsorption No adsorption Operating ED Switch main circuit 88 ON OFF Operating ED Switch main circuit 88 Pressure indication Pressure indication Brown: Power supply oad Black: switch output 1 oad White: Switch output 2 Blue: Common Brown: Power supply Black: Switch output 1 White: switch output 2 oad oad Blue: Common

Space Saving acuum Ejector Series ZQ Dimensions Type K1 ZQ1 1U-K1 - - Pilot exhaust port ( port) Note 4) (M3, Atmospheric release) Air supply port (P port) Note 4) (M) 29.4 20.3 P Circuit diagram 3 ead wire length (approx. 0.3 m) (49.) Type J1 ZQ1 1U-J1 - - Pilot exhaust port ( port) Note 4) (M3, Atmospheric release) 29.4 20.3 P Air supply port (P port) Note 4) (M) P Circuit diagram 0.8 P 30. 0.8 (74.9) ZQ1 1U-K1 - D - (3.1) (Grommet type) EXH 3. (AC type) (With -type plug connector) (3.1) ZQ1 1U-J1 - D - F - EXH (With -type plug connector) (3.1) 3 20.2 13.1 32 17. 23 33 2 (Body mounting hole) 3 20.2 Supply valve 2 x ø3.2 through D K - Supply valve 2 x ø3.2 through (Body mounting hole) F - 17.7 22.8 Bracket A (Standard) 4 x ø3. Mounting hole Bracket A (Standard) acuum release valve 2.8 17.7 22.8 7 Note 1) 7 Note 1) acuum release flow adjustment needle Suction filter Exhaust part Suction filter Exhaust part.9 acuum pressure switch 8.3 71.9 acuum pressure switch.9 8.3 71.9 S RUN H H SMC S RUN H H SMC kpa MODE SET HYS kpa MODE SET HYS acuum port ( port) Note 4) (M) Note 1) The above dimensions are for ZQ1 1U-K1 -D C. In case of ZQ1 1U-K1 -F, the overall length is 87.2. Note 2) Dimensions marked with are those after bracket A is mounted. Note 3) When the body is mounted, tighten with a torque of 0. ± 0.0 Nm. Using excessive torque may cause damage to the body. Note 4) The pitches of P and ports are determined assuming the use of the KJ series one-touch fittings. If used with other fittings, these may cause interference, dependant on their type and size. Please refer to the catalog to confirm the sizes of the fittings to be used. 9.7 9.7 acuum port ( port) Note 4) (M) Note 1) The above dimensions are for ZQ1 1U-J1 -D C. In case of ZQ1 1U-J1 -F, the overall length is 87.2. Note 2) The dimensions after bracket A is mounted are the same as those of the K1 type. Note 3) When the body is mounted, tighten with a torque of 0. ± 0.0 Nm. Using excessive torque may cause damage to the body. Note 4) The pitches of P and ports are determined assuming the use of the KJ series one-touch fittings. If used with other fittings, these may cause interference, dependant on their type and size. Please refer to the catalog to confirm the sizes of the fittings to be used. 18

Series ZQ Dimensions Type K2 ZQ1 1U-K2 - - acuum release flow adjustment needle (With -type plug connector) Supply valve Bracket A (Standard) 2.8 acuum release valve Suction filter Pilot exhaust port ( port) Note 4) (M3, Atmospheric release) 2 x ø3.2 through (Body mounting hole) Air supply port (P port) Note 4) (M) 29.4 20.3 P 0.8 (8.4) 3 20.2 17.7 22.8 87.2 Note 1) Exhaust part 8.3 9.7 acuum port ( port) Note 4) (M) P Circuit diagram EXH ZQ1 1U-K2 - F - D - D K - Note 1) The above dimensions are for ZQ1 1U-K2 -F. In case of ZQ1 1U-K2 -D, the overall length is 7. Note 2) The dimensions after bracket A is mounted are the same as those of the K1 type. Note 3) When the body is mounted, tighten with a torque of 0. ± 0.0 Nm. Using excessive torque may cause damage to the body. Note 4) The pitches of P and ports are determined assuming the use of the KJ series one-touch fittings. If used with other fittings, these may cause interference, dependant on their type and size. Please refer to the catalog to confirm the sizes of the fittings to be used. Type J2 ZQ1 1U-J2 - - (With -type plug connector) Supply valve Bracket A (Standard) Suction filter Pilot exhaust port ( port) Note 4) (M3, Atmospheric release) 2 x ø3.2 through (Body mounting hole) Air supply port (P port) Note 4) (M) 29.4 20.3 P 0.8 (8.4) 3 20.2 17.7 22.8 87.2 Note 1) 8.3 Exhaust part 9.7 acuum port ( port) Note 4) (M) P Circuit diagram 19 ZQ1 1U-J2 - F - EXH D - Note 1) The above dimensions are for ZQ1 1U-J2 -F. In case of ZQ1 1U-J2 -D, the overall length is 7. Note 2) The dimensions after bracket A is mounted are the same as those of the K1 type. Note 3) When the body is mounted, tighten with a torque of 0. ± 0.0 Nm. Using excessive torque may cause damage to the body. Note 4) The pitches of P and ports are determined assuming the use of the KJ series one-touch fittings. If used with other fittings, these may cause interference, dependant on their type and size. Please refer to the catalog to confirm the sizes of the fittings to be used.

A A Space Saving acuum Ejector Series ZQ Dimensions Type Q1 ZQ1 1U-Q1 - - ZQ1 1U-N1 - - B 0 acuum release flow adjustment needle (With -type plug connector) Supply valve Bracket A (Standard) 2.8 acuum release valve Suction filter acuum pressure switch Pilot exhaust port ( port) Note 4) (M3, Atmospheric release) Air supply port (P port) Note 4) (M) 29.4 20.3 P 0.8 (3.1) (Body mounting hole) 3 20.2 2 x ø3.2 through 3. 17.7 22.8 7 Note 1) Exhaust part.9 8.3 71.9 S RUN H H SMC kpa MODE SET HYS 9.7 acuum port ( port) Note 4) (M) P Circuit diagram Q ZQ1 1U- N 1 - D - EXH F - D K - Q Note 1) The above dimensions are for ZQ1 1U- N 1-D C. Q In case of ZQ1 1U- N 1 -F, the overall length is 87.2. Note 2) The dimensions after bracket A is mounted are the same as those of the K1 type. Note 3) When the body is mounted, tighten with a torque of 0. ± 0.0 Nm. Using excessive torque may cause damage to the body. Note 4) The pitches of P and ports are determined assuming the use of the KJ series one-touch fittings. If used with other fittings, these may cause interference, dependant on their type and size. Please refer to the catalog to confirm the sizes of the fittings to be used. Type Q2 ZQ1 1U-Q2 - - ZQ1 1U-N2 - - 0 B (With -type plug connector) Supply valve Bracket A (Standard) Suction filter acuum pressure switch Pilot exhaust port ( port) Note 4) (M3, Atmospheric release) Air supply port (P port) Note 4) (M) P 29.4 20.3 P 0.8 Circuit diagram ZQ1 1U- Q N2 - D - (3.1) (Body mounting hole) 3 20.2 2 x ø3.2 through EXH 3. F - 17.7 22.8 7 Note 1) Exhaust part.9 Q Note 1) The above dimensions are for ZQ1 1U- N 2 -D C. Q In case of ZQ1 1U- N 2 -F, the overall length is 87.2. Note 2) The dimensions after bracket A is mounted are the same as those of the K1 type. Note 3) When the body is mounted, tighten with a torque of 0. ± 0.0 Nm. Using excessive torque may cause damage to the body. Note 4) The pitches of P and ports are determined assuming the use of the KJ series one-touch fittings. If used with other fittings, these may cause interference, dependant on their type and size. Please refer to the catalog to confirm the sizes of the fittings to be used. 8.3 71.9 S RUN H H SMC kpa MOD E S E T HYS 9.7 acuum port ( port) Note 4) (M) 20

Series ZQ Dimensions Manifold type (without PD port) ZZQ1 -BSB ZQ1 3M- - - Supply valve. (Body mounting hole) 3. 2 x R1.7 Pilot exhaust port ( port) (One-touch fitting: Applicable tubing O.D. ø4, Release to the atmosphere.) Common air supply port (P port) (One-touch fitting: Applicable tubing O.D. ø8) acuum release valve P 2 1 13 (Pitch) P = acuum release flow adjustment needle 8 P 2 x ø3. (Body mounting hole) Note 1) 3 (With -type plug connector) 2.8 7 Exhaust part Suction filter acuum pressure switch (3.) (0.1) Attached washer Attached washer (72.4).2 S RUN H H SMC kpa MO DE SET HYS S RUN H H SMC kpa MO DE SET HYS S RUN H H SMC kpa MO DE SET HYS S RUN H H SMC kpa MO DE SET HYS 9 8. 28.8 81 7 Note 1) 8. 9 21 acuum port ( port) Note 4) (M) Dimensions n 1 1 2 2 42 2 3 2 3 4 2 4 72 82 7 92 7 8 2 (mm) 8 9 112 Note 1) The above dimensions are for ZZQ1 -BSB. ZQ1 3M-K1 -D C. In case of ZQ1 3M- -F, the overall length is 87.2. Note 2) Dimensions marked with " " are those after the attached square bracket is mounted. Note 3) When the body is mounted, tighten with a torque of 0. ± 0.0 Nm. Using excessive torque may cause damage to the body. Note 4) The pitches of ports are determined assuming the use of the KJ series onetouch fittings. If used with other fittings, these may cause interference, dependant on their type and size. Please refer to the catalog to confirm the sizes of the fittings to be used. EXH P P EXH Circuit diagram 21 ZQ1 3M-K1 -D - ZQ1 3M-K2 -D K- ZQ1 3M-J1 -F- ZQ1 3M-Q1 -FK-

0 0 k S S S H H H Space Saving acuum Ejector Series ZQ Dimensions Manifold type (with PD port) ZZQ1 -BSC ZQ1 3M- - - Supply valve Pilot exhaust port ( port) (One-touch fitting: Applicable tubing O.D. ø4, Release to the atmosphere.) PD P Common air supply port (P port) (One-touch fitting: Applicable tubing O.D. ø8) acuum release valve acuum release pressure supply port (PD port) (One-touch fitting: Applicable tubing O.D. ø4) 2 8 1 (Pitch) P = 13 B A P B A PD acuum release flow adjustment needle 4 x M through (for mounting) 12.2 13. 13.. 79 8.9 Note 2) 3. (300: lead wire length) 2.4 Suction filter acuum pressure switch (72.4) H RUN SMC Pa MODE SET HYS SMC H RUN kpa MODE SET HYS SMC H RUN kpa MODE SET HYS Note 1) The above dimensions are for ZZQ4-BSC. ZQ1 3M-K1 -D C ZQ1 3M-K2 -D ZQ1 3M-J1 -F ZQ1 3M-Q1 -D In case of ZQ1 3M- -F, the overall length is 91.7. In case of ZQ1 3M- -D C, the overall length is 111.. Note 2) The above dimensions are for ZQ1 3M- K J 2 -. EXH P PD 90 111. Note 1) Dimensions n 1 1 2 2 3 3 4 2 42 2 2 72 82 92 2 112 Note 3) When the body is mounted, tighten with a torque of 0. ± 0.0 Nm. Using excessive torque may cause damage to the body. Note 4) The pitches of ports are determined assuming the use of the KJ series one-touch fittings. If used with other fittings, these may cause interference, dependant on their type and size. Please refer to the catalog to confirm the sizes of the fittings to be used. Note ) When the vacuum release valve is not used, design the circuit for vacuum release separately in order to release a workpiece. 4.2 21 7 acuum port ( port) (M) P PD EXH 7 8 (mm) 8 9 ZQ1 3M-K1 -D - 0 ZQ1 3M-K2 -D ZQ1 3M-J1 -F- 0 ZQ1 3M-Q1 -D - 0-0 Circuit diagram 22

Series ZQ Dimensions Fittings / Fitting type filter dimensions after installation port (Suction filter, acuum pressure switch) KJS23-M Applicable tubing O.D.: ø3.2 acuum () port KJS04-M Applicable tubing O.D.: ø4 acuum () port KJS0-M Applicable tubing O.D.: ø acuum () port 1. 1. 1.4 1.3 1. KJ23-M KJ04-M ø8.4 ø9.3. Applicable tubing O.D.: ø3.2 acuum () port Applicable tubing O.D.: ø4 acuum () port P port Applicable tubing O.D.: ø4 Supply (P) port Applicable tubing O.D.: ø Supply (P) port Applicable tubing O.D.: ø4 Supply (P) port ø9.3 KJS04-M KJS0-M KJ04-M 1. 1. 1.4. 23

Space Saving acuum Ejector Series ZQ Made to Order Please contact SMC for detailed dimensions, specifications, and lead times. Port Exhaust Specifications Manifold ZZQ1 Stations B2B X12 Port exhaust specifications Exhaust port is changed for Port Exhaust Specifications. Dimensions Manifold type (without PD port) ZZQ1 -B2B-X12 ZQ1 3M- - 2 x Rc 1/4 EXH. port P 8 P 2 24

Series ZQ Manifold Exploded iew e y y r y b r y b) view w a) part t a) part t Component Parts No. 1 2 3 4 Description Hexagon socket head cap screw End block End block R Ejector assembly Ejector body gasket for manifold Exhaust block gasket Note 1) Refer to page 11 and 12 for detailed description of How to Order. Note 2) pcs. are included in one set. t Part no. Refer to How to Order below. Refer to Table (1) (including 1 pc. of y). q Refer to Table (1) (including 1 pc. of t). Note 1) ZQ13M-- Table (1) (1 pc. each in t and y is included.) Description Note 2) ZQ-3-00-AS End block Note 2) ZQ-3-009-AS End block R With PD port ZQ1-2-BSB-AS ZQ1R-2-BSB-AS Without PD port ZQ1-1-BSB-AS ZQ1R-1-BSB-AS How to Order Hexagon Socket Head Cap Screw ZQ STB Note) 2 pcs. are included in one set. 2 0 Number of stations 01 1 station 02 2 stations 08 8 stations Working Procedure Disassembly oosen and remove the hexagon socket head cap bolts q. Assembly 1. Install the ejector body gasket for manifold t into the gasket groove of each ejector assembly r. Install the exhaust block gasket y around the projected part. 2. Install the exhaust block gasket y around the projected part of the end block w. 3. Install the ejector body gasket for manifold t into the gasket groove of the end block R e. 4. Align the ejector assemblies r, end block () w, and end block (R) e using positioning pins (at the two a positions) and fasten with hexagon socket head cap bolts q (2 pcs.) (with a tightening torque of 0. Nm ± 0.0 Nm).

2

Space Saving acuum Pump System Series ZQ How to Order acuum Pump Unit ZQ00 U K1 D31 C q w e r t y u i o!0 q Body type U M For single unit For manifold w Solenoid valve combination (Refer to Table (1).) e Pilot valve (Refer to Table (1).) r Solenoid valve rated voltage (Refer to Table (1).) Symbol K1 Note 1) K2 J1 Note 1) J2 Q1 Q2 N1 N2 Supply valve Normally closed Normally open Normally closed Normally open atching positive common atching positive common atching negative common atching negative common acuum release valve Normally closed Normally closed None None Normally closed None Normally closed None Y Standard (DC: 1 W) Note 1) DC low wattage type (0. W) Note 1) Note 2) Avoid energizing the solenoid valve for long periods of time. (Refer to Specific Product Precautions 1; Caution on Design and Selection.) 1 2 3 4 0 AC (0/0Hz) 200 AC (0/0Hz) 1 AC (0/0Hz) 220 AC (0/0Hz) 24 DC 12 DC The air in the adsorption section of this product is not released to the atmosphere at the vacuum suspension state. As for K1, K2, Q1 and N1, use the vacuum release valve when a workpiece is detached. Concerning J1, J2, Q2 and N2, devise the circuit for the vacuum release additionally when a workpiece is detached. Note 1) In cases when K2 or J2 (supply valve normally open) is selected for the solenoid valve combination, when vacuum is stopped for long periods of time ( minutes or more), do not continue to energize the supply valve, and shut off the air supply. Table (1) Combination of Solenoid alve, Pilot alve and Rated oltage Solenoid valve Combination combination Pilot valve no. symbol symbol 0 AC 200 AC q w e r t y u i o!0 K1 K1 K2 J1 J1 J2 Q1 Q2 N1 N2 Y Y Combinations q to!0 in the above table are the only possible options. Applicable power supply voltage () 1 AC 220 AC 24 DC 12 DC 27

Space Saving acuum Pump System Series ZQ t Electrical entry Note 3) y Manual override O -type connector, with 0.3 m lead wire, with light/surge voltage suppressor -type connector, without connector, with light/surge voltage suppressor Non-locking push type atching type: Push-locking type B ocking type (Q1/Q2/N1/N2: Not applicable) Note 3) atching type supply valve: Available in only. In this case, the supply valve and release valve come with a lock. G Grommet, with 0.3 m lead wire (atching/ac type: Not applicable) Note 4) u acuum pressure switch suction filter i acuum switch electrical entry F D31 With suction filter only 1 NPN output + Analog output, with suction filter, Pressure range 0 to 0 kpa C C CN Connector type, with 0. m lead wire Connector type, with 3 m lead wire Connector type, without connector D32 2 NPN outputs, with suction filter, Pressure range 0 to 0 kpa D1 1 PNP output + Analog output, with suction filter, Pressure range 0 to 0 kpa D2 2 PNP outputs, with suction filter, Pressure range 0 to 0 kpa Note 4) The filter included in this product is of an simple type, and will become clogged quickly in environments with high quantities of dust or particulates. Please make additional use of an air suction filter of the ZFA, ZFB or ZFC series. Warning The filter case of this suction filter is made of nylon. Contact with alcohol or similar chemicals may cause it to be damaged. Also, do not use the filter when these chemicals are present in the atmosphere. Note ) o Fitting ( port) Note, )!0 Fitting (PS / P port) Symbol 0 1 2 3 4 Applicable tubing O.D. Without fitting (M x 0.8) ø3.2 (Straight) ø4 (Straight) ø (Straight) ø3.2 (Elbow) ø4 (Elbow) Part no. KJS23-M KJS04-M KJS0-M KJ23-M KJ04-M Note ) When neither port fitting nor PS/P port fitting are needed, enter nothing or 00 in the dotted line above How to Order. Symbol Applicable tubing O.D. 0 Without fitting (M x 0.8) 2 ø4 (Straight) 3 ø (Straight) ø4 (Elbow) Note ) Manifold type: Not applicable Part no. KJS04-M KJS0-M KJ04-M 28

How to Order Manifold ZZQ1 0 Number of stations 01 1 station 02 2 stations 08 8 stations acuum release pressure supply port (PD port) B C acuum pressure supply port (P port) PS port location (Refer to Table (1).) eft side R Right side Table (1) Air Supply Port ocation on the Manifold PD port B C Manifold PS port location (eft side) R (Right side) (eft side) R (Right side) PS Note) eft P PD PS Note) Right P PD Manifold Ordering Example ZZQ8-R0B 1 pc. ZQ00M-K1-D32C 4 pcs. (Stations 1 to 4) ZQ00M-K1Y-D2C 4 pcs. (Stations to 8) Note) The stations are sequentially numbered. When viewed from the side of the vacuum ports, the far left station is designated as station 1. eft Right kpa S1 H RUN MODE SET1 H SET2 H RUN H S2 S2 Series ZQ 08 None (Release pressure is supplied from the PS port.) Provided (Air can be alternatively supplied from the PS port.) Note) The position of each port is shown in terms of its location when vacuum port is in front. Release pressure is supplied from the PS port. kpa kpa kpa kpa kpa kpa kpa S1 H RUN S1 H RUN S1 H RUN S1 H RUN S1 H RUN S1 MODE S1 SET1 SET2 H RUN H S2 MODE SET1 H S2 MODE SET1 H S2 MODE SET1 H S2 MODE SET1 H S2 M O D E SET1 H S2 M O D E SET1 SET2 SET2 SET2 SET2 SET2 SET2 acuum port 1 2 3 4 7 8 ZQ00M-K1-D32C ZQ00M-K1Y-D2C 29