PRESSURE SEQUENCE VALVE TYPE UZK

Similar documents
WK /2 WAY CARTRIDGE VALVE TYPE URZS 32 COVER FOR CARTRIDGE VALVE TYPE ULZS 32. Size 32 up to 42 MPa 700 dm 3 /min DESCRIPTION OF OPERATION

Pressure reducing valve, direct operated, type DR 5 DP Huade América 1

Pilot operated pressure relief valve sandwich plate,type ZDB/Z2DB6 Huade América 1

Pressure reducing valve, pilot operated, Model 3DR

Pressure reducing/relief valve, pilot operated type UZCP10

Pressure reducing valve, pilot operated

Pressure reducing valve, direct operated, sandwich plate, type ZDR6D...40B/(New Series)

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R

Directional spool valves type WE6 electrically. operated type WE6 series 32

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R

Double throttle/check valve, Type Z2FS Series 30 Huade América 1

Check valve hydraulically pilot operated

Pressure reducing valve, direct operated

Electrically Operated Pressure-Relief Cartridge, Size 10

RE / Meter out pressure compensator Sandwich plate design Type SCA... /Series 2X. Description of function, Section 1/6. Replaces: 09.

Pressure relief valve, direct operated Type DBD

Pressure relief valve, direct operated

Check Valves. Pilot Operated Check Valves. Vickers. 4CG-10, 20 Series 4CS-03, 20 Series 4CT-06/10, 20 Series. Basic Characteristics.

Explanations hydraulic valves TECHNICAL EXPLANATIONS HYDRAULIC VALVES. Contents. 1. Foreword. 2. Characteristic Values

Size 6 up to 31.5MPa 1) up to 25 L/min

Inverse Proportional Pressure-Relief Cartridge, Size 10

Pressure reducing valve, direct operated

Digital directional & flow control valves D-DF(R)G

BW0500AO. ByWire Elements BW0500AO Element 4/3 with side ports IBW0500 Interface

Pressure relief valves

P2* MODULAR SUBPLATES FOR ISO (CETOP 03) VALVES

2-way flow control valve Model 2FRM 6

Dual displacement motor A10VM Plug-in dual displacement motor A10VE for open and closed circuit applications

Safety and Shut-off Block SAF/DSV

3-Way Safety Block DSV

Intrinsically safe solenoid valves on/off controls - ATEX certification

INVERS. Solenoid coil 24VDC 12 VDC Exm Exd Explosion protection marking:

Prop. 3-Way Pressure-Reducing Cart., Size 5 / SAE 08

Pressure relief valve, direct operated

Safety and Shut-off Block SAF/DSV

Function. Valve Size. Pilot Oil. p min. Bold: Designates Tier I products and options.

Auxiliary valve QDS6 Sequence valve, 3-way. Catalogue (GB) (US) October 1998

Meter-in pressure compensator, direct operatedtype ZDC

Leak free Pipe Rupture Valve for Excavators

Pressure relief valve, direct operated. Type DBD. Features. Contents. RE Edition: Replaces:

Flow Controls. DG**-06 Series Stacking Valves. Vickers. ISO (D06) Interface Flows to 340 l/min (90 USgpm) Pressure to 210 bar (3000 psi)

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R

Digital relief valves D-CG

Safety and Shut-off Block SAF/DSV

Inverse Proportional Pressure-Relief Cart., Size 2 4

Inverse Proportional Pressure-Relief Cart., Size 2 4

Inverse Prop. Pressure-Relief Cart., Size 2 4

Fixed Displacement Plug-In Motor A2FE

VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10

Industrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US

Proportional Throttle Cartridges, Size 16

Proportional Pressure-Relief Cartridge Valve, Size 2...4

Safety and Shut-off Block SAF/DSV

Directional Controls

Proportional Pressure-Relief Cartridge Valve, Size 2...4

SOLENOID VALVES AND PNEUMATIC VALVES

Pump safety block. Type DBA, DBAW, DBAE(E) Features. Contents. RE Edition: Replaces: 11.10

EXH. Specifications. Descriptions. Min. working pressure MPa

Directional Controls

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

Sandwich Valves. 1 Change in flow, temperature or fluid (SSU) rating will affect valve

MOUNTING SURFACE MOUNTING POSITION MAXIUMUM OPERATING PRESSURE FLUID OPERATING VISCOSITY FLUID CLEANLINESS HYSTERESIS REPEATABILITY THRESHOLD VOLTAGE

Fixed Displacement Motor A4FM

VICKERS. SystemStak Valves. ISO ; NFPA-D03; 315 bar (4500 psi); 60 L/min (15.7 USgpm) GB 2027B

Safety and Shut-off Block SAF/DSV

Hand & mechanical directional valves

1 LS unloading (control valve, orifice, none) 2 LS max pressure relief. 3 Spool type

E 328 E 498 Tank top mounting Connection up to G1½ / -24 SAE and SAE 2 Nominal flow rate up to 600 l/min / gpm

APPLICATION. Conveyors Metal working machines Machines for agriculture Road building machines Mining machinery Food industries

E 328 E 498 Tank top mounting Connection up to G1½ and SAE 2 Nominal flow rate up to 600 l/min

E 158 E 198 E 248. Tank top mounting Connection up to G11 / 4 Nominal flow rate up to 250 l/min e d

Axial Piston Variable Pump A10V(S)O (US-Version)

TANDEM MODULATOR FOR OUTLET GAS FLOW: STEPPED (836 TANDEM) - CONTINUOUS (837 TANDEM) SERVO-CONTROLLED PRESSURE REGULATOR

Specifications. Model VEX Operating style Fluid Proof pressure Max. operating pressure

E 084 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 80 l/min / 21.1 gpm

Fixed Displacement Pump KFA for commercial vehicles in open circuits

Displacement 12, , Maximum flow rate (at 1450 rpm) bar.

SPC*01 (2-way) SPC03/06 (2-way) Size NG6 NG10 NG16 NG25 DIN A10 ISO 4401 NFPA D05 CETOP 5 P, A, B:

Manapak Sandwich Valves Series CM, CPOM, FM, PRDM, PRM, RM

Series K Air service units G 1/8, G 1/4

Cooler-Bypass Thermostat Valve, Size 16

D 042 D 062 In-line mounting Operating pressure up to 100 bar Nominal flow rate up to 90 l/min

3-Way Pressure-Reducing Cartridge, Size 2 4

TECHNICAL CHARACTERSTICS

PVQ 13 A2 R SE 1 S 20 C-11 D

OMS Technical Information Technical data

Over-center valves type LHT with oscillation damping, zero leakage

MV-01. Features. 2/2-way Solenoid Valve for Fluids. Description: Application:

Change-Over Pressure Filter DFDK

Air preparation units

Power Valve: Precision Regulator. High precision, large capacity relief regulator

D62 - D63 Directional Control Valve l/min

DNS. Monoblock directional control valves DNS - Directional control valve

Double Pilot Operated Cartridge Check Valve, Size 8

Air service units series K G1/8, G1/4

DENISON HYDRAULICS vane pumps - single, double T6G - T67G - T6ZC

Ex-proof solenoid valves with spool position monitor on/off, with inductive proximity sensor - Multicertification ATEX, IECEx, EAC

M18x1,5 ISO Pilot operated pressure relief valve

Vickers. Flow Controls. Flow Controls FN, F(C)G, FRG. Released 6/94

Ball valve-combinations 105 Shut-off blocks with integrated bypass and safety-lock 106 Sandwich plates 108 Accumulator safety blocks 114

Transcription:

PRESSURE SEQUENCE VALVE TYPE UZK Size 10, 20, 30 31,5 MPa up to 450 dm 3 /min WK 450 414 04. 2000r. Pressure sequence valves type UZK are used for switching a system or part of a system off when a set pressure is reached. DESCRIPTION OF OPERATION Pilot operated pressure sequence valve comprises the pilot valve 6 and the main valve 1. Pressure at port A acts on the main spool 3 and simultaneously on the pilot spool 7 via a control line. At the same time the pressure affects the main spool surface opposite to the spring 4 by means of a bore in the main spool fitted with the jet 5. The spring 8, tensioned according to pilot pressure, holds the pilot spool in centre position. When set pressure is exceeded, the pilot spool moves to the right. It allows fluid to drain from the spring chamber of the main spool into line B via the control line fitted with a jet, if the valve is applicable as a relief valve or sequence valve. The jet combination causes a pressure difference between the lower and upper sides of the main spool. The main spool is shifted upwards. The connection from A to B is thus open, while system pressure remains unchanged. 1 WK 450 414

Pressure sequence valve is also available with directional valve unloading. The valve described previously has been enlarged by mounting a directional control valve 9. In the starting position, the directional valve blocks the drain line in front of the pilot poppet. In switched position, the directional valve 9 connects the spring chamber of the main spool with a tank. The spring side of the main spool is thus unloaded and the spool moves opening the connection from A to B. The valve is available in two versions : in de-energized position normally open and normally closed. TECHNACAL DATA Hydraulic fluid Mineral oil or phosphate ester Nominal fluid viscosity 37 mm 2 /s at the temperature of 328 K Viscosity range 2.8 to 380 mm 2 /s Optimum working temperature( fluid in a tank ) 313-328 K Fluid temperature range Required fluid filtration Recommended fluid filtration 253-343 K up to 16 µm up to 10 µm Maximum operating pressure 31.5 MPa Input pressure at port A Output pressure at port B up to 31.5 MPa 21 MPa Maximum backpressure 21 MPa Max allowable flow rate Weight Size 10 Size 20 Size 30 150 dm 3 /min 300 dm 3 /min 450 dm 3 /min 5.5 kg For technical data on directional control valve WE 5 see WK 450 187 WK 450 414 2

OVERALL AND CONNECTIONS DIMENSIONS Admissible surface roughness and flatness deviation for a subplate face. 1 - O-ring for size 10-17.1 2.6-2 pcs 1 - O-ring for size 20-28.2 3.5-2 pcs 1 - O-ring for size 30-34.5 3.5-2 pcs 2 - O-ring for size 10-9.2 1.8-2 pcs 2 - O-ring for size 20-9.2 1.8-2 pcs 2 - O-ring for size 30-9.2 1.8-2 pcs Nominal size B1 B2 H1 H3 H4 L1 10 85 66.7 112 28 72 96 20 102 79.4 122 38 82 112 30 120 96.8 130 46 90 140 L2 L3 L4 L5 Weight [kg] 42.9-34.6 35.6 up to 5.0 60.3-36.9 33.5 up to 6.9 84.2 42.1 31.3 28 up to 9.6 3 WK 450 414

Pressure sequence valve for manifold block mounting 1 - O-ring 27.3 2.4-2 pcs 2 - O-ring 9.2 1.8-3 pcs Valve seat for mounting in manifold blocks WK 450 414 4

D1 D2 D3 Size 10 10 40 10 Size 20 20 45 20 Size 30 30 45 30 Bolts mounting the valve 4 x M8 x 40-10.9 PN-87/M-82302 ( DIN - 912 ) Torque [Nm] 37 37 37 PERFORMANCE CURVES, measured at ν = 41 mm 2 /s and T = 323 K 25 22,5 NG 10 25 22,5 NG 20 20 20 p wej (MPa) 17,5 15 12,5 10 p wej (MPa) 17,5 15 12,5 10 7,5 7,5 5 5 2,5 2,5 0 25 50 75 100 125 150 0 50 100 150 200 250 300 3 3 Input pressure in relation to flow for size 10 Input pressure in relation to flow for size 20 25 22,5 NG 30 2,5 NG 30 20 2,0 p wej (MPa) 17,5 15 12,5 10 7,5 p wej (MPa) 1,5 1,0 NG 10 NG 20 5 0,5 2,5 0 75 150 225 300 375 450 3 0 150 300 3 450 Input pressure in relation to flow for size 30 Input pressure in relation to lowest pressure setting ( in relation to flow for open and closed valve ) 5 WK 450 414

4,0 2,0 NG 30 3,0 NG 10 1,5 p (MPa) 2,0 NG 20 NG 30 p nast. (MPa) 1,0 NG 10 NG 20 1,0 0,5 0 150 300 450 0 75 150 225 300 375 450 3 3 Pressure drop in relation to flow Lowest pressure setting in relation to flow SCHEMES WK 450 414 6

HOW TO ORDER Orders coded in the way showed below should be forwarded to the manufacturer. _ UZK * Further requirements in clear text ( to be adreed with the manufacturer ) Sealing Fluids on mineral oil base = with no code Fluids on phosphate-ester base = V Electrical connection Plug-in connector = Z4 Lerge plag-in connector = Z5 Large plug-in connector with light = Z5L Emergency operation Without emergency operation With emergency operation = no code = N Voltage for solenoids AC 220 V, 50 Hz = W220-60 AC 110 V, 50 Hz = W110-50 DC 24 V = G 24 DC 110 V = G 110 Directional control valve ( for UZK...E only ) In de-energized position normally closed = AE In de-energized position normally open = BE Check valve With check valve Without check valve = Z = no code Adjustment Handknob = 1 Set screw with internal hexagon = 2 Lockable handknob = 3 Pilot supply and drain Pilot suply internal, drain internal Pilot supply external, drain internal Pilot supply internal, drain external Pilot supply external, drain external = W = X = Y = Z Pressure setting 10 MPa = 100 21 MPa = 210 Series number 13 = 13 ( 10-19 ) - installation and connection dimensions remain unchanged Nominal size Size 10 = 10 Size 20 = 20 Size 30 = 30 Coding example : UZKP 10-13 / 210 W1 Mounting and operating Pilot operating, subplate mounting Pilot operating, manifold mounting Pilot only = P = S = B 7 WK 450 414

Subplates for sequence valves 1 - Recess in subplate face 2 - Mounting surface Valve Subplate D1 D2 T1 G 460/01 28 G 3/8 13 Size 10 G 461/01 34 G 1/2 15 Bolts mounting the valve to subplate 4 x M10 x 50-10.9 PN - 87/M-82302 (DIN 912 ) Torque [Nm] Weight [kg] 73 1.7 1 - Recess in subplate face 2 - Mounting face Valve Subplate D1 D2 T1 Size 20 G 412/01 42 G 3/4 17 G 413/01 47 G 1 20 Bolts mounting the valve to subplate 4 x M10 x 60-10.9 PN - 87/M-82302 (DIN 912 ) Torque [Nm] Weight [kg] 73 3.3 WK 450 414 8

1 - Recess in subplate face 2 - Mounting face Valve Subplate D1 D2 T1 G 414/01 56 G 1 1/4 21 Size 30 G 415/01 61 G 1 1/2 23 Bolts mounting the valve to subplate 6 x M10 x 70-10.9 PN - 87/M-82302 (DIN 912 ) Torque [Nm] Weight [kg] 73 5 Note : Subplates and fixing bolts have to be ordered separately 9 WK 450 414

NOTES : 10 WK 450 414