mhhhhee 15 DEVELOPMENT OF A LOW NOISE ilk JT REFRIGERAYON SYSTEM In1

Similar documents
AN EXPERIMENTAL INVESTIGATION ON HELIUM LIQUEFACTION USING TWO-STAGE GIFFORD McMAHON CRYOCOOLER

JT Micro Compressor Test Results

TECHNICAL DATA. Q = C v P S

Development of High Efficiency 4K Two-Stage Pulse Tube Cryocooler

CVI Valve Line. Exceeds the industry s highest standards for reliability and performance

TECHNICAL DATA. Q = C v P S

Mass Flow Controller (MFC) for Gases

All Molybdenum Hot Zone & Elements. All Insulators are made of High Alumina. Element style - 1/8 Molybdenum Wire.

TECHNICAL DATA. Q = C v P S

D R A F T. Operating Procedures for the NPDGamma Liquid Hydrogen Target at the BL 13. Version 1.00

An Investigative and Synoptic Review on Helium Liquefaction Using a Commercial 4 K Gifford- McMahon Cryocooler

Short Introduction to Cryo-Pumps and Refrigerators. Dr Graham Rogers Leybold UK Ltd.

Current Leads for Cryogenic Systems

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA OBSOLETE

VIC offers a variety of Calibrated Gas Leaks

Microscopy Cryogenic WORKSTATION. Performance by Design

Hermetic Cover Seal Process Technology MIL-STD-883 TM 1014 Seal

TECHNICAL DATA. Q = C v P S

v. Size shall be specified on drawings.

AC : MEASUREMENT OF HYDROGEN IN HELIUM FLOW

Earlier Lecture. In the earlier lecture, we have seen Kapitza & Heylandt systems which are the modifications of the Claude System.

Continuously Variable Inertance Tubes for Pulse Tube Refrigerators

DRAFT. Operating Procedures for the NPDGamma Liquid Hydrogen Target in TA-53, Building MPF-35

Detector Carrier Gas Comments Detector anode purge or reference gas. Electron Capture Nitrogen Maximum sensitivity Nitrogen Argon/Methane

TESTING SAFETY OF HYDROGEN COMPONENTS

Dilution Refrigerator manual

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

Flexible Metal Hose Products

Manual Solvent Purification System. Innovative Technology, Inc.

Micro Channel Recuperator for a Reverse Brayton Cycle Cryocooler

JANIS OPERATING INSTRUCTIONS FOR SUPERCONDUCTING MAGNET CRYOSTATS

ENGLISH Datasheet IEC Miniature Thermocouple Connector Socket with Stainless Steel mounting bracket Types K, J, T, E, N, B & Copper (IEC Colour Code)

Hydro / Helium Test Report. 10 August Abstract

Specification Sheet. Equipment Model: J-VAC-12 High Vacuum Furnace. Type. Chamber. Maximum Temperature 1250 C. Hot Zone

Judson Technologies PB 219. JTC JOULE-THOMSON CRYOSTAT COOLING SYSTEM Operating Instructions. October, 2003

AWWA C504 COMPLIANT VALVES FROM 3 THRU 108

TECHNICAL REPORT. TB Series Ball Valve. Report No: ILDTR Revision: 0 Total Pages: 19 Date: 14/02/12

Slit Valve. XGT Series. Low particle generation. With end lock mechanism. Service life of two million cycles. XLA XL XL Q D- XSA XVD XGT CYV

Bio-sample testing on an adaptation to a tensile testing machine

Берг АБ Тел. (495) , факс (495) Turning Ideas Into Engineered Solutions KAYDON RING & SEAL, INC.

EXPERIENCE WITH A PRE-SERIES SUPERFLUID HELIUM TEST BENCH FOR LHC MAGNETS

Vortex flowmeters. Product family introduction Principle of operation Product review Applications Key product features

Vibration-Free Joule-Thomson Cryocoolers for Distributed Microcooling

Gas Lines. Technical Manual. Sumitomo (SHI) Cryogenics of America, Inc Vultee Street Allentown, PA U.S.A.

Baffles and Traps Cryotrap

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

WHAT ARE THE SPECIFICATIONS FOR THE ARGON GAS OPTION USED IN JOULE THOMSON REFRIGERATORS?

Finding Leak Testing Success Through Calibration and Validation. Paul Chamberlain President, CEO

NITROGEN PURGING SYSTEMS FOR THE HVAC INDUSTRY VISION INNOVATION SOLUTION

TIGHTNESS. Glass sealing Thanks to our glass-sealing technology, ODU products can meet the most demanding tightness requirements.

Variable Temperature Storage Dewar Mount Inserts

A Journal of Practical and Useful Vacuum Technology. By Phil Danielson

Cooling Characteristics of GM-type Pulse Tube Refrigerator with Neon as Working Gas

Multiple Gas#5 GC configuration Jan 2016

Mid InfraRed Instrument (MIRI) Cooler Cold Head Assembly Acceptance Testing and Characterization

TELEDYNE PB 219. JUDSON TECHNOLOGIES A Teledyne Technologies Company TELEDYNE JUDSON TECHNOLOGIES JTC JOULE-THOMSON CRYOSTAT COOLING SYSTEM

TECHNICAL DATA. Q = C v P S

RC102 & RC110 Sample in Vacuum Continuous Flow Cryogenic Workstation Cryostats

Design Features. General Description

Brazed Heat Exchangers

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY

Homestead Series 820 AWWA Butterfly Valves

Two-port seat valves

RDK-408D2 Cold Head. Technical Manual. SHI-APD Cryogenics Inc Vultee Street Allentown, PA U.S.A. Revision A: September 2005

The Model L1410 can be counted on for many years of trouble-free, reliable operation.

MASS FLOW SYSTEMS MASS FLOW MEASURING, CONTROLLING AND BLENDING SYSTEMS

Copyright, 2005 GPM Hydraulic Consulting, Inc.

Thermal Profiling the Reflow Process

TECHNICAL DATA. Q= Cv S

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13

Slide and Turn System SF35

E SC 412 Nanotechnology: Materials, Infrastructure, and Safety Wook Jun Nam The Pennsylvania State University

A Rationale for Pressure Relief Device(s) Qualification Requirements (LH2)

Mass Flow Meter (MFM) for Gases

Flange Bolt Torquing. for Resistoflex Plastic-Lined Piping Products. Torquing. Retorquing. Hydrotesting. Annual retorquing

Datasheet ANSI Standard Duplex Thermocouple Connector Sockets Types K, J, T, E, N, R/S & B (ANSI Colour Code)

[Instruments for vacuum measurement, checking and adjustment] 3

Specialty Products. Specialty Products Index

CONTROL VALVE TESTING

Vickers. Filters. Reservoir Vent Filters. Spin-on Air Filters & Adaptors. Rev. 3/98

tel: fax: web:

INTRODUCTION TABLE OF CONTENTS

Flexible Engineered Solutions International CALM Buoy Swivels

Product Test Report F.A. Lennon Drive December 2015 Solon, Ohio U.S.A. Page 1 of 7. Valve Series Description Test Pressure Test Qty.

Weld seams without temperature discoloration every time!

Experimental Investigation on Stirling type Thermally Coupled Three Stage Pulse tube Cryocoolers with U type Configuration

Magnet and RF Cavity Test Stand Design. Tom Peterson, SLAC USPAS January, 2017

ASTM 3612/TOGA/Dissolved Gas GC Revised October 2013

How to specify a product. Process Sensors and Mechanical Instruments

Instruction Manual. CG16K Barometrically Compensated Capsule Dial Gauge. CG16K Capsule Dial Gauge, 0 to 25 mbar

Development of a Miniaturized Pressure Regulation System "mprs"

Improvements in the Reliability, Costs and Processing of WLP/RDL Circuits

VACGEN. Vacuum Components. Product Overview

Development Report. Walker Barrier 10 Ergoclean Gloveport Interface. And. Single Piece Gauntlet Performance Testing

Series Environmental Chambers

Major Design Features

M A B MAB INFLATABLE GASKET SLIDE VALVES SERIES TSV FOR POWDERED AND GRANULAR SOLID MATERIALS

[The Octopus vacuum lifting system] 9

Premium Series. Economical Price & Reliable Performance. High Quality. Rust-Resistant. Long Life. Tamper-Resistant locking Screw.

Transcription:

15 DEVELOPMENT OF A LOW NOISE ilk JT REFRIGERAYON SYSTEM In1 (U) NNR TECHNOLOGIES INC MOUNTAIN VIER CA FED 86 I N99114-95-C-0428 UNCLASSIFIED F/G 13/1 ML mhhhhee

-V."kr 97 111..i 97 % -C. - - ' V - -W,- -... 12. 11111 I12.2 I IIIg 111=...,,!... o... o<,. l ".1' M11 IO MCOOYRSO l.o LUTI ON TE ST CH ART r 1.25 14-1.6. 1111 MICROOPY ESOLTIONTESTCHAR

Lin Deelpmn of a LoNis a.. -. Cotrc No N001.5--02 Development of a Low Noise --- 1OK J.T. Refrigeration Systen.'""'... [.E Final Technical Report O 1AC MA 71 1400 Stierlin Road, #A-5 A Mountain View, CA 94043 ~Cha FWia 11 A,- Litt le iran 86 2 24 196i "... - - -

".*,,-.. :,_ C-. -". w i,- -' '.. - - o. -.-. - ---.-. v. '..- J;. I... ABSTRACT The purpose of this Lonzruct is the development of a Low Noise, Closed Cycle Joule-Tnomson refrigeration system for 1OK operation. This report summarizes work completed to date on the fabrication of the first two stages of the cooler. The argon stage has been tested an has been found to meet the cooldown time specification. Testing of the hydrogen stage will be done shortly. Design of the helium stage has been completed and tne photomasks prepared. The hydraulically actuated, single gas compressor has been modified for higher pressure operation and has been tested. Satisfactory operation has been obtained and life testing is beginnning. Y- I Avfii3 -ty CodeS Dist special W-3 "4,S

#,,....%l 1.0 INTRODUCTION >-This report summarizes the results of an engineering design program) undertaken by MMk Technologies,--Inc-., for the Uffice of Naval Rese ch under Contract No. N00014-85-C-0428. The purpo'sepogram is - ---- to develop a low noise, closed cycle, Joule-Thomson, microminiature refrigeration system for IOK operation. During this period the effort has been focussed on the fabrication of the argon and hydrogen stages of the three stage cooler. A test facility was designed and built which allows one to mount each refrigerator on a separate removable base ana to test each in turn. This is described in Section 2.1. P... Key to the successful fabrication of the refrigerator is the determination of the proper firing profile for sealing the refrigerator components. Three batches of refrigerators have been built to date, and reasonable yields are now being obtained for the fabrication of these stages. The details of the firing profiles are reported irn Section 2.2.,The helium stage has been designed and laid out, and the photomasks prepared. 'These are described in Section 2.3. Al, In Section 2.4 the results obtained to date with these refrigerators are sumiarized. Work has continued on the hydraulically actuated compressor. on this is reported in Section 3. Progress 2.0 REFRIGERATOR FABRICATION AND TEST In the early stages of the development of a new refrigerator it is usually necessary to test a large number of refrigerators to determine what refinements must be made in the design. To do this it is necessary to have a reuseable test facility to which each refrigerator can be bonded and after test, removed. Such a test facility has been designed and built for the test of the three stage cooler. 2.1 Test Facility The design of the test facility was based on one used previously for the test of fast cooldown refrigerators for operation to 8UK. This consisted of a vacuum chamber with feedthroughs for thermocouples, diode thermometers and resistance heaters, and a removable base flange for the refrigerator. The refrigerator mounting flange was modified to be made of stainless steel so that the seven gas lines to the refrigerator could be hydrogen brazed to the steel base rather than soft soldered. This gives a cleaner and more reliable bond than the soft soldered joints used -... -..

J..*.- previously. Two, five gas-line bases were furnace brazed in a hydrogen atmosphere using pure copper as the brazing alloy. These were designed for use in testing the argon and hydrogen stages prior to the addition of the helium stage. An additional two, seven gas-line bases were also brazed by the same method for use with the complete cooler. 2.2 Refriqerator Fabrication, With the completion of the pnotomasks for the argon and hydrogen stages, fabrication was started on the component parts for these stages. This part of the refrigerator consists of five layers, however, to test this part without the final helium stage in place, a blank-off layer of glass is needed as a sixth layer. This was added to the stack. To date three batches have been prepared in an effort to determine the best firing profile (time vs. temperature) in the furnace. Each batch consisted of four refrigerators. L Batch #1 - The firing profile used for fabricating the MMR standard product 80K refrigerator was used for this batch. Incomplete sealing of the layers occurred with several voids on some layers in each refrigerator. The refrigerators were refired using a longer ramp and high bake temperatures. The voids remained and no useable refrigerators were obtained. batch #2 - The longer ramp and higher bake temperature described above was used. Three refrigerators still had voids but one was sealed perfectly. The good one was used for initial tests of flow and cooldown time. Batch #3 - A similar ramp and bake were used for #2. All samples were free of voids but two had channels collapsed in layer four containing the finest capillaries for the hydrogen stage. The other two were perfect. The reason for the difference between batches two and three is not known at present. Further examination of the refrigerators and data from the next batch should clear this up. Z-A The present firing profile gives a sufficient number of refrigerators to refine the design for the depths of the channels. Later the profile can be optimized to improve the yield. 2.3 Helium Stage Design The helium stage of the refrigerator has been designed. It was designed to make optimum use of the available heat exchanger surface area. This has been laid out, the rubylith cut and the photomasks prepared. In Figure 2.2, the step-and-repeat pattern of this layer is shown to scale, and in Figure 2.3 the detail of the step-and-repeat pattern for the final outflow channel. These parts will be fabricated as soon as tests on the argon and hydrogen stages are completed. -2

......... ILI,..

0iLi Figure 2.2 Step-and-Repeat pattern of helium inflow channels. Actual sze. -4-

%'-.. I.. o.,.o. I -5 C Figure 2.3 Laminar flow, low pressure helium stage outflow channpi. Actual size.

2.4 Test Results Refrigerator #006, the first successfully fired refrigerator frofr the second batch, was mounted on the test facility flange and tested for leaks. No leaks were detected. A calibrated silicon diode thermometer was cemented to the top of the refrigerator immediately above the argon reservoir which is positioned at the 2.00 pmi position in layer #2. This is shown in Figure 2.4. For these tests the top of the refrigerator was 'N sealea with a blank-off layer of glass across the entire top surface. In addition, in order to give the refrigerator added strength during these initial tests, the thin slot between the hydrogen stage and the amibient temperature mounting point was not * cut (see Figure 2.5). Measurements were then taken of the gas flow through the main argon heat exchanger ("short outflow") and the laminar flow, low pressure heat exchanger ("long outlfow") as a function ot pressure. Next, the refrigerator was allowed to cool ana the time to reach a steady state measured. This was done using argon and then nitrogen gas at pressures up to 135 atm. The flow through the two heat exchangers as a function of pressure, for argon is shown in Figure 2.6. At 135 atmn. input pressure, using argon, the refrigerator cooled to minimum temperature in 2.4 minutes. A second sample (#U11) cooled in 2.0 minutes. The minimum temperature reached was 104K. This is higher than the design value and indicates a higher back pressure in thie final boiler. Corrections for this will be made in the next iteration where a deeper long outflow channel will be used. The two samples were damaged before the hydrogen stages could be measured. Two new samples are being mounted and will be tested shortly. -6-

Argon reservoi Figure 2.4 Layer #2 showing location of argon reservoir. -7-

J 'q MLi Slot Figure 2.5 Location of slot separating hydrogen reservoir from ambient temperature mounting point.

ONR Refrigerator 00b Argon Flow Test 1.0 Shortg Outflow 1.00 0.0 1000 2000 Pressure (psi) Figure 2.6 Flow vs. pressure data for Argon stage. Main heat exchanger (Short Outflow) and low pressure heat exchanger (Long Outflow). 9% 7'-

.. i. 3.0 COMPkESSUr DEVELOPMENT As discussed in the previous report, the only majur problem encountered in the first four hundred hours of operation of the first, single gas compressor, was the leakage of hydraulic fluid past the rod I. " -I seals of the hydraulic compressor. The low pressure hydraulic cylind r has no% been replaced with one rated for operation at 3,00U psi. In addition the end plates of botn the low and high pressure cylinders have been redesigned and strengthened to provide a more secure mount for the valve assemblies. Tne new unit has been tested. Some adjustments hag to be made in the timing cycle to compensate for the difference in the volume of the new cylinder. When these were made it operated satistactorily and proviaeo 4.0 liters/minute at 2,000 psi. It is now bein% set up for L continuous operation to determine thf rate of wear of the seals. 4.0 ObJECTIVES OF THE NEXT REPOk:TING PEkIUL During the next reporting period it is expected that the following tasks will be completed or will be under way. a) Test and characterization of the argon and hydrogen stages. o) Fabrication of the helium stage. l c) Firing of the complete three stage cooler. d) Initial measurements will be done on the complete cooler. e) Long term testing of the single gas compressor will be under way. f) The design work on the three gas compressor will be under way. 0-10 -

.. Ob. *V de.~~~...