E 094 E 103 E 143 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 135 l/min / 35.7 gpm

Similar documents
E 441 E 451 E 461 E 641 E 700 Tank mounting Nominal flow rate up to 800 l/min

E 212 E 222 Tank top mounting Connection up to G1¼ / -20 SAE Nominal flow rate up to 220 l/min / 58.1 gpm

E 212 E 222 Tank top mounting Connection up to G1¼ Nominal flow rate up to 220 l/min

D 042 D 062 In-line mounting Operating pressure up to 100 bar Nominal flow rate up to 90 l/min

E 084 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 80 l/min / 21.1 gpm

E 328 E 498 Tank top mounting Connection up to G1½ / -24 SAE and SAE 2 Nominal flow rate up to 600 l/min / gpm

E 158 E 198 E 248. Tank top mounting Connection up to G11 / 4 Nominal flow rate up to 250 l/min e d

E 328 E 498 Tank top mounting Connection up to G1½ and SAE 2 Nominal flow rate up to 600 l/min

Pressure reducing valve, pilot operated, Model 3DR

Change-Over Pressure Filter DFDK

FIK In-Tank Filters FIK. Max Flow: 170 gpm (643 lpm) Working Pressures to: Rated Static Burst to: Flow Range to:

Pressure reducing valve, pilot operated

Desiccant Air Breathers DBE. Section 3: TNK SCHROEDER INDUSTRIES ACCESSORIES 21

D e s c r i p t i o n

MPS/MST SPIN - ON FILTER SUCTION - RETURN SERIES. Maximum working pressure 12 bar. Flow rates to 300 l/min

Check Valves. Pilot Operated Check Valves. Vickers. 4CG-10, 20 Series 4CS-03, 20 Series 4CT-06/10, 20 Series. Basic Characteristics.

Pressure reducing valve, direct operated

Flow rates to 200 l/min

Air preparation units

Displacement 12, , Maximum flow rate (at 1450 rpm) bar.

PLD 03 T A CASAPPA S.p.A.

VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10

Check valve hydraulically pilot operated

Fixed Displacement Pump KFA for commercial vehicles in open circuits

Pressure reducing valve, direct operated

Auxiliary valve QDS6 Sequence valve, 3-way. Catalogue (GB) (US) October 1998

Pressure relief valve, direct operated

Compressed Air Conditioning Catalog Chapter I

2-way flow control valve Model 2FRM 6

BUTTERFLY VALVES. Toll Free (877) - ICFLUID -2-

Spin-On Filters SSF 24,25

Pilot Check Valve: Metal Body Type

SPM. Pressure Filters MEDIUM PRESSURE INLINE FILTER

Installation and commissioning instructions 255 series and 256 series

HIGH PRESSURE FILTERS DFDK Series Inline Duplex Filters 4568 psi up to 90 gpm

Pressure-Relief Cartridge Valve, Size 4

Prop. 3-Way Pressure-Reducing Cart., Size 5 / SAE 08

Proportional Pressure-Relief Cartridge Valve, Size 2...4

Type 4708 Supply Pressure Regulator

3-Way Safety Block DSV

LMP 110 Maximum pressure 80 bar F l o w r a t e s t o l / m i n

EXH. Specifications. Descriptions. Min. working pressure MPa

Type 4708 Supply Pressure Regulator

LMP Filter element in according to DIN Style B. Style S. Maximum pressure 30 bar F l o w r a t e s t o l / m i n D.I. D.I.

Variable Displacement Double Pump A20VO. Series 1, for open circuits Axial piston - swashplate design, Back to back - design

Booster Regulator/Air Tank

Type 4708 Supply Pressure Regulator

List of Contents vma. Compressed Air Conditioning 2. System description 2. Individual Units Pre-Filters 3. Combinations 6

3-Way Pressure-Reducing Cartridge, Size 2 4

Auto Feed Lube, Auto Feed Tank ALF400 to 900, ALT-5/-9

L6090 (LC04M-CBL) - L6095 (LC04M-CBD)

Inverse Prop. Pressure-Relief Cart., Size 2 4

Pressure relief valve, direct operated

WK /2 WAY CARTRIDGE VALVE TYPE URZS 32 COVER FOR CARTRIDGE VALVE TYPE ULZS 32. Size 32 up to 42 MPa 700 dm 3 /min DESCRIPTION OF OPERATION

Full Range Pressure Compensating Variable Flow Control

Electrically Operated Pressure-Relief Cartridge, Size 10

Compressed Air Cleaning Filter Series

STAD-C. Balancing valves DN 15-50

ALF400 to 900, ALT-5/-9

Series SFD. Clean Air Filter. Variations. Made to Order. Type. Cartridge (replaceable element) Disposable (non-replaceable element) Up to 100

Related Products: Auto Drain Valve. Model/Specifications. Model

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R

Type Pressure Regulator. for increased air capacity. Fig. 1: Type Pressure Regulator. Mounting and Operating Instructions EB EN

Fixed Displacement Motor A4FM

Fuel Filters DN15 DN25. elektrogas.com DE

SATURNSERIES INTERCHANGE > ISO (for the couplings)

VACUUM REGULATORS CONTENTS

INSTALLATION GUIDE MODEL NUMBER X. UniMaxx-Plus-SC-500-AC-V3 UNIMAXX SOLAR PUMP STATION

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R

Directional Control Valves Technical Information Model 1500

RE / Meter out pressure compensator Sandwich plate design Type SCA... /Series 2X. Description of function, Section 1/6. Replaces: 09.

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

directional control valve series cv691

Technical Data Sheet TI-F50 Locking Units series KFH

Principles of Filtration. Filter Elements. High Pressure Filters. Section 4. Tank-Mounted, Return Line and Medium Pressure Filters

P2* MODULAR SUBPLATES FOR ISO (CETOP 03) VALVES

Dual displacement motor A10VM Plug-in dual displacement motor A10VE for open and closed circuit applications

Standard Operating and Maintenance Instructions for Pumping System Model PS-150

Fixed Displacement Plug-In Motor A2FE

D62 - D63 Directional Control Valve l/min

Directional Controls

lternative odels 3.87 (98) anual Drain 2.67 (68) 3.72 (94) utomatic Drain 2.13 (54) 1.12 (28) P1H, PTH Filter/Regulator-Lubricator Combination Units 0

Double Pilot Operated Cartridge Check Valve, Size 8

Directional Controls

Pressure Relief Valves. SPV, SPVF direct operated

Safety and Shut-off Block SAF/DSV

HPB25 Hydraulic Paving Breaker

Self-priming makes priming unnecessary Exhausts the air inside the suction pipe to suck up liquid. Air operated type.

Pneumatic proportional controller Types M Types FM Function tested for use of the float in Ex-zone 0

Pressure relief valve, direct operated. Type DBD. Features. Contents. RE Edition: Replaces:

Leak-Free Load-Control Valve SAE ½ psi flange

F05MSV-N* CONTINENTAL HYDRAULICS FLOW CONTROL VALVE, NON-COMPENSATED WITH CHECK F05MSV-N* - FLOW CONTROL VALVE, NON-COMPENSATED WITH CHECK

Pressure reducing valve, direct operated, sandwich plate, type ZDR6D...40B/(New Series)

Proportional Pressure-Relief Cartridge Valve, Size 2...4

Gas Filters DN15 DN300. elektrogas.com EE151 06/13

CV08-20 Check Valve DIRECTIONAL VALVES. DESCRIPTION A screw-in, cartridge-style, hydraulic check valve for use as a blocking or load-holding device.

Pressure booster. Air Service Units Series Page. General 5.1. Pressure boosters ø Pressure boosters ø 40 c/w air pressure regulator 5.

Series ZFC. Air Suction Filter In-line Type with One-touch Fittings

Pilot operated pressure relief valve sandwich plate,type ZDB/Z2DB6 Huade América 1

Pressure reducing valve, direct operated, type DR 5 DP Huade América 1

Transcription:

Return Filters E 9 E E Tank top mounting Connection up to G / -6 SAE Nominal flow rate up to 5 l/min / 5.7 gpm Description Application In the return line circuits of hydraulic systems. Performance features Protection against wear: By means of filter elements that even in full-flow filtration meet the highest demands regarding cleanliness classes. Protection against malfunction: By means of full-flow filtration in the system return, the pumps above all are protected from dirt particles remaining in the system after assembly, repairs, or which are generated by wear or enter the system from outside. Special features By-pass valve: The location close to the inlet port prevents dirt particles retained by the filter element from entering into the clean oil side. Removable bowl: In case of maintenance the filter bowl is removed together with the filter element - therefore dirt particles are not flushed back into the tank. Extension pipe: A correct extension pipe length ensures oil outlet below minimum oil level and prevents foaming. Return Filter E Filter elements Flow direction from outside to center. The star-shaped pleating of the filter material results in: large filter surfaces low pressure drop high dirt-holding capacities long service life Ventilating Filter Ventilation of the reservoir by an integral star-shape pleated filter element: removable (replace annually!) splash-proof fineness µm Filter maintenance By using a clogging indicator the correct moment for maintenance is stated and guarantees the optimum utilization of the filter life. Subject to change.-en/us 88 Page

Materials Screw-on cap: Filter head: Filter bowl: Seals: Filter media: Polyamide, GF-reinforced Aluminum alloy Polyamide, CF-reinforced, electrically conducting NBR (FPM on request) EXAPOR MAX - inorganic multi-layer microfiber web Paper - cellulose web, impregnated with resin Accessories Electrical and optical clogging indicators are available on request. Dimensions and technical data see catalog sheet 6.. An optional oil separator ( E.7) prevents oil splashing through the ventilating filter at mobile applications and is available on request. Extension pipes on the bowl outlet are available in several lengths on request. Characteristics Nominal flow rate Up to 5 l/min / 5.7 gpm (see Selection Chart, column ). The nominal flow rates indicated by ARGO-HYTOS are based on the following features: closed by-pass valve at ν mm /s / 97 SUS element service life > operating hours at an average fluid contamination of.7 g per l/min /.7 g per gpm flow volume flow velocity in the connection lines.5 m/s /.8 ft/s Connection Threaded ports according to ISO 8 or DIN SAE standard J5 Sizes see Selection Chart, column 6, (other port threads on request). Filter fineness 5 µm(c)... µm(c) β-values according to ISO 6889 (see Selection Chart, column and diagram Dx). Dirt-holding capacity Values in g test dust ISO MTD according to ISO 6889 (see Selection Chart, column 5). Hydraulic fluids Mineral oil and biodegradable fluids (HEES and HETG, see info-sheet.). With high filling conditions we recommend an electrical conductivity 5 ps/m at C / 68 F. Temperature range - C... + C (temporary - C... + C) - F... + F (temporary - F... +8 F) Viscosity at nominal flow rate at operating temperature: ν < 6 mm /s / 8 SUS as starting viscosity: ν max = mm /s / 556 SUS at initial operation: The recommended starting viscosity can be read from the diagram D (pressure drop as a function of the kinematic viscosity) as follows: Find the 7% p of the cracking pressure of the by-pass valve on the vertical axis. Draw a horizontal line so that it intersects the p curve at a point. Read this point on the horizontal axis for the viscosity. Operating pressure Max. bar / 5 psi Mounting position Preferably vertical, outlet downwards. Page Subject to change.-en/us 88

Diagrams p-curves for complete filters in Selection Chart, column D.,., Pressure drop as a function of the flow volume at ν = 5 mm /s / 6 SUS ( = casing empty) Q [gpm] 6.6. 9.8 6.. 9.6.5,5 7. E 9 5.8. Pressure drop as a function of the kinematic viscosity at nominal flow 5 ν [SUS] 97 85 78 78 65 7.5 58..5.,.,.9.5 9..5 5 5 75 5 5 Q [l/min] 6 8 ν [mm /s] D Pressure drop as a function of the flow volume at ν = 5 mm /s / 6 SUS ( = casing empty) Pressure drop as a function of the kinematic viscosity at nominal flow Q [gpm] 6.6. 9.8 6.. 9.6.5,5 7..,.,.,., E + 5.8..9.5 5 ν [SUS] 97 85 78 78 65 7.5 58..5 9..5 5 5 75 5 5 Q [l/min] 6 8 ν [mm /s] D.,.,.,., Pressure drop as a function of the flow volume at ν = 5 mm /s / 6 SUS ( = casing empty) Q [gpm] 6.6. 9.8 6.. 9.6.5,5 7. E + 5.8..9.5 Pressure drop as a function of the kinematic viscosity at nominal flow 5 ν [SUS] 97 85 78 78 65 7.5 58..5 9..5 5 5 75 5 5 Q [l/min] 6 8 ν [mm /s] Subject to change.-en/us 88 Page 5

Filter fineness curves in Selection Chart, column Dx Filtration ratio β for particles > x µm Filtration ratio β as a function of particle size x obtained by the Multi-Pass Test according to ISO 6889 Particle size x [µm] (for particles larger than the given particle size x) Efficiency [%] The abbreviations represent the following β-values resp. finenesses: For EXAPOR MAX and Paper elements: 5EX = β 5 (c) = EXAPOR MAX 7EX = β 7 (c) = EXAPOR MAX EX = β (c) = EXAPOR MAX 6EX = β 6 (c) = EXAPOR MAX P = β (c) = Paper Based on the structure of the filter media of the P paper elements, deviations from the printed curves are quite probable. For screen elements: S = screen material with mesh size µm 6S = screen material with mesh size 6 µm S = screen material with mesh size µm Tolerances for mesh size according to DIN 89 For ventilating filter elements: CL = 99.5 % filter efficiency for particles of size µm For special applications, finenesses differing from these curves are also available by using special composed filter material. Page 6 Subject to change.-en/us 88

Selection Chart Nominal flow rate Pressure drop see diagram D/curve no. Dirt-holding capacity Filter fineness see Diagr. Dx Connection A Cracking pressure of by-pass Symbol Replacement element l/min g bar kg 5 6 7 8 9 E 9-66 5 D/ P G /.5 P.6-5.8 L.5- (CL) - E 9-67 5 D/ P G /.5 P.6-5.8 - - Weight Replacement ventilating filter (Filter fineness, see diagrams) Remarks E -657 5 D/ 5EX 8 G¾.5 V.6-5. L.5- (CL) - E -677 5 D/ 5EX 8 G¾.5 V.6-5. - - E -676 8 D/ EX 5 G /.5 V.6-56. L.5- (CL) - E -686 8 D/ EX 5 G /.5 V.6-56. - - E -898 D/ 6EX 5 G.5 V.6-58. L.5- (CL) - E -888 D/ 6EX 5 G.5 V.6-58. - - E -87 7 D/ P G /.5 P.6-5. L.5- (CL) - E -86 7 D/ P G /.5 P.6-5. - - E -657 7 D/ 5EX 8 G /.5 V.7-5. L.5- (CL) - E -667 7 D/ 5EX 8 G /.5 V.7-5. - - E -676 5 D/ EX 8 G.5 V.7-56. L.5- (CL) - E -686 5 D/ EX 8 G.5 V.7-56. - - E -888 5 D/ 6EX 8 G.5 V.7-58. L.5- (CL) - E -688 5 D/ 6EX 8 G.5 V.7-58. - - E -85 D/ P 7 G.5 P.7-5. L.5- ( CL) - E -86 D/ P 7 G.5 P.7-5. - - Preferred type, no minimum order quantity required Paper media supported with metal gauze All filters are delivered with a plugged clogging indicator connection M x.5. As clogging indicators either manometers or electrical pressure switches can be used. Optional extension pipes adapt the filter length to various tank depths. For ordering of accessories please use the below mentioned codes. Order example: The filter E -676 has to be supplied with an extension pipe for a mounting depth of 5 mm. Order description: E -676 / EV 5 (Basic unit) Mounted extension pipe (7 various lengths are available on request) E 9: EV, EV 9, EV, EV 8, EV, EV, EV 5 E : EV 96, EV 56, EV, EV 5, EV, EV 5, EV 6 E : EV 97, EV 57, EV, EV 5, EV 5, EV 6, EV 7 For the suitable clogging indicators please see catalog sheet 6.. Remarks: The switching pressure of the electrical pressure switch has always to be lower than the cracking pressure of the by-pass valve (see Selection Chart, column 7). Clogging indicators are optional and always delivered detached from the filter. The filters listed in this chart are standard filters. Other designs available on request. Subject to change.-en/us 88 Page 7

Selection Chart Nominal flow rate Pressure drop see diagram D/curve no. Dirt-holding capacity Filter fineness see Diagr. Dx Connection A Cracking pressure of by-pass Symbol Replacement element Weight Replacement ventilating filter (Filter fineness, see diagrams) gpm g SAE psi lbs 5 6 7 8 9 E 9-76. D/ P -6 P.6-5.8 L.5- (CL) incl. oil separator E 9-75. D/ P -6 P.6-5.8 - - Remarks E -76.9 D/ 5EX 8-6 6 V.6-5. L.5- (CL) incl. oil separator E -75.9 D/ 5EX 8-6 6 V.6-5. - - E -777. D/ EX 5-6 6 V.6-56. L.5- (CL) incl. oil separator E -756. D/ EX 5-6 6 V.6-56. - - E -798 9. D/ 6EX 5-6 6 V.6-58. L.5- (CL) incl. oil separator E -788 9. D/ 6EX 5-6 6 V.6-58. - - E -76 8.5 D/ P -6 P.6-5. L.5- (CL) incl. oil separator E -75 8.5 D/ P -6 P.6-5. - - E -76 8.5 D/ 5EX 8-6 6 V.7-5.7 L.5- (CL) incl. oil separator E -75 8.5 D/ 5EX 8-6 6 V.7-5.7 - - E -776. D/ EX 8-6 6 V.7-56.7 L.5- (CL) incl. oil separator E -786. D/ EX 8-6 6 V.7-56.7 - - E -788 5.7 D/ 6EX 8-6 6 V.7-58.7 L.5- (CL) incl. oil separator E -798 5.7 D/ 6EX 8-6 6 V.7-58.7 - - E -76.7 D/ P 7-6 P.7-5.7 L.5- ( CL) incl. oil separator E -75.7 D/ P 7-6 P.7-5.7 - - Preferred type, no minimum order quantity required Corresponds to 5 /6 - UN-B Paper media supported with metal gauze All filters are delivered with a plugged clogging indicator connection M x.5 mm. As clogging indicators either manometers or electrical pressure switches can be used. Optional extension pipes adapt the filter length to various tank depths. For ordering of accessories please use the below mentioned codes. Order example: The filter E -76 has to be supplied with an extension pipe for a mounting depth of 5 mm (resp. 9.69 inch). Order description: E -76 / EV 5 (Basic unit) Mounted extension pipe (7 various lengths are available on request) E 9: EV (5. inch), EV 9 (7.8 inch), EV (9. inch), EV 8 (.8 inch), EV (.5 inch), EV (7.9 inch), EV 5 (. inch) E : EV 96 (7.7 inch), EV 56 (.8 inch), EV (.8 inch), EV 5 (.78 inch), EV (5.7 inch), EV 5 (9.69 inch), EV 6 (.6 inch) E : EV 97 (.69 inch), EV 57 (.6 inch), EV (5.7 inch), EV 5 (7.7 inch), EV 5 (9.69 inch), EV 6 (.6 inch), EV 7 (7.56 inch) For the suitable clogging indicators please see catalog sheet 6.. Remarks: The switching pressure of the electrical pressure switch has always to be lower than the cracking pressure of the by-pass valve (see Selection Chart, column 7). Clogging indicators are optional and always delivered detached from the filter. The filters listed in this chart are standard filters. Other designs available on request. Page 8 Subject to change.-en/us 88

Dimensions I +(EV-K) B S S Ventilating filter fineness µm (replaceable) H A G F Oil separator optional ARGO-HYTOS E.7 EV K Ø C Ø D U Dia hole in reservoir Max. oil level under stationary conditions when using an oil separator V ØE For dimension EV see selection chart Design without ventilating filter Design with ventilating filter Required mounting surface Connection M x.5 O for clogging indicator Q 9º 5º T 9º 5º M L L c 9º Q P N P I R Measurements in mm Type A B C min./max. D E F G H I I K L M N O E 9 G ¾ 5 87/9 7.5 8.5 88.5 5 5 5 7 E G¾, G 5 87/9 7.5 8.5 88.5 5 77 5 7 E G¾, G 5 87/9 7.5 8.5 88.5 5 78 5 7 Type P P Q R S T U V E 9 8 69.5 7.5 AF AF 5 E 8 69.5 7.5 AF AF 5 E 8 69.5 7.5 AF AF 5 Measurements in inch Type A SAE B C min./max. D E F G H I I K L M N O E 9-6../.58.9.5.8.8.8 9.5.9.7.5..76. E -6../.58.9.5.8.8.8.8.9 6.97.5..76. E -6../.58.9.5.8.8.8 5.75.9.9.5..76. Type P P Q R S mm T mm E 9..7.5. AF AF.97.9 E..7.5. AF AF.97.9 E..7.5. AF AF.97.9 * Corresponds to 5 /6 - UN-B U V Subject to change.-en/us 88 Page 9

Symbols A P A P Spare Parts B B 5 6 7 8 9 Pos. Designation Screw-on cap E. Flat gasket N.8 Compression spring N5.7 Replacement filter element see Chart / col. 9 5 Filter bowl E9* E 9.9 5 Filter bowl E* E.9 5 Filter bowl E* E.9 6 O-ring N7.7 69.5 x.5 mm.7 x. inch 7 Replacement ventilating filter L.5-K 8 Housing (for pos. 7) L.5.8 9 Flat gasket (for versions E.7 without oil separator) Oil separator (incl. pos. ) E.7 Flat gasket (for versions E.8 with oil separator) *Specify mounting depth (EV) in mm The functions of the complete filters as well as the outstanding features of the filter elements assured by ARGO-HYTOS can only be guaranteed if original ARGO-HYTOS spare parts are used. Quality Assurance Quality management according to DIN EN ISO 9 To ensure constant quality in production and operation, ARGO-HYTOS filter elements undergo strict controls and tests according to the following ISO standards: ISO 9 ISO 9 ISO 9 ISO 968 ISO 6889 ISO 8 Verification of collapse / burst pressure rating Verification of fabrication integrity (Bubble Point Test) Verification of material compatibility with fluids Evaluation of pressure drop versus flow characteristics Multi-Pass-Test (evaluation of filter fineness and dirt-holding capacity Determination of resistance to flow fatigue using high viscosity fluid Various quality controls during the production process guarantee the leakfree function and solidity of our filters. Illustrations may sometimes differ from the original. ARGO-HYTOS is not responsible for any unintentional mistake in this specification sheet. Page Subject to change.-en/us 88