Index 7.1. Page R2 12/99

Similar documents
Index 7.1. Page R2 12/99

Hip Air Operated Valves

General Information valve design valve selector guide catalog numbering system warranty terms

Air Operated Hydraulic Pumping Systems to 50,000 psi

High Pressure Equipment Taper Seal Valves, Fittings and Tubing

Specialty Products. Specialty Products Index

High Pressure Equipment Medium Pressure Valves, Fittings and Tubing

High Pressure Equipment Medium Pressure Valves, Fittings and Tubing

SPECIFICATIONS. Approximate Weight: 10 oz. Surface Finish: Ra micro inch or less MATERIALS OF CONSTRUCTION

High Pressure Equipment 2 - Medium Pressure Valves, Fittings and Tubing 20,000 psi service

Standard Operating and Maintenance Instructions for Pumping System Model PS-90

CVI Valve Line. Exceeds the industry s highest standards for reliability and performance

Go to Table of Contents. Ball and Plug Valves

High Pressure Equipment Pressure Vessels and Reactors Index

Ball Valves Subsea Series

Precision and Instrument Regulators 1/4" port size

PRO-50 Instrument Supply Regulator

Series 2G Diaphragm Actuators

Hydrogen Valves, Fittings and Tubing

THE BP-690 SERIES. Operating and Service Manual. Series includes all variants of BP-LF/MF-690/691

BULLETIN FOR ACCURATE INDICATION AND CONTROL OF GAS AND LIQUID FLOW IN LOW RANGES.

MEGR-1627 Instruction Manual

Description Advanced Features Typical Applications

SG TF. Q = 963 Cv (P1 - P2)(P1 + P2) TECHNICAL INFORMATION. Flow Q (GPM)

High Pressure Check Valves

BERMAD Waterworks. Level Control Valve with Altitude Pilot. 700 Series. Model X. Features and Benefits. Major Additional Features

V43 Pressure Actuated Water Regulating Valve

Pneumatic Powered - Plunger Pumps

MEGR-1912 Instruction Manual

Control Valve : The Final Control Element. Nimish Shah

Chlorinator. MODEL C-731 (Floor Mounted)

CASH VALVE TYPE KP BACK PRESSURE VALVES

Standard Operating and Maintenance Instructions for Pumping System Model PS-150

Choosing the right miniature instrument and control valve is a snap

Brooks Flow Controllers for Gas and Liquid Service Model FC 8744, Series FC 8800 and 8900

NOTES. ITT CONOFLOW - QUICK REFERENCE GUIDE Airpak, Filter-Regulator / Filter Only

A BRIEF TUTORIAL ON GAS HANDLING EQUIPMENT

INDUSTRIAL VALVES MODELS: C62-A; C62-D. INSTRUCTION MANUAL Installation Operation Parts Service DIAPHRAGM BYPASS PRESSURE REGULATING VALVES

Welker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual

INSTRUMENTATION VALVES

Suggested Installation & Operating Instructions for Sidewinder Pumps

1800CPB2 Service Regulators Maximum Inlet Pressure 125 PSIG

Operation Manual Piston Sensed Gas Pressure Regulators

Pressure Sensing Valve - Model 4023

shutoff valves 900 Series psig Manual Shutoff Valves

Cash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified

DataSheet. Series AA Electronic Metering Pumps. Configuration Data. Dimensions. Specifications. Model AA HI. ISO 9001 Certified

Petro-Chemical & Analyzer Sampling Systems

REGULATORS FOR SPECIFIC APPLICATIONS

SINGLE VALVE WITH LOW-FLOW BYPASS

THE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401

Petro-Chemical & Analyzer Sampling Systems

Operation Manual. Diaphragm Sensed Gas Pressure Regulators

Valve Proving System VDK 200 A S02

Valve Proving System VDK 200 A S06*

CFC2. Float Control For Closed Tanks MODEL. Specifications. Dimensions (In Inches) Reservoir Connection 1" NPT (Typ. Both Ends 2 Places)

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

MANUAL BE SERIES Test Benches

INSTRUCTION MANUAL. CVS P37 LP Gas Reducing Regulator

Type 1098-EGR. Pilot-Operated Valve Link Regulators. Features. Fisher Controls

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

Product Manual. Description. Specifications. CVS Type 1301F and CVS Type 1301G Regulator. Introduction

JR Series. Gas Pressure Reducing Valves. a division of Jordan Valve GAS PRESSURE REDUCING VALVES

Brooks Flow Controllers for Gas and Liquid Service Model FC 8744, Series FC 8800 and FC 8900

JR Series. Gas Pressure Reducing Valve GAS PRESSURE REDUCING VALVE

Model 1800 PFM Series Regulator. Technical Bulletin

Medium Pressure Valves, Fittings and Tubing Pressures to 21,000 psi

Model PRS-07i. Stainless Steel Low Pressure, In-Line Pressure Regulator (Reducing Valve)

Total Pressure Regulator Solutions.

Models 461-S, 461-8S and S Regulators. R-1330 Rev. 7

Pressure Equalising Valves Model , for Differential Pressure Gauges

Installation, Operation and Maintenance Manual for Back Pressure Regulator

PVQ 13 A2 R SE 1 S 20 C-11 D

SECTION BUTTERFLY VALVES

Models: C62/63/64-A/D

1800CPB2 Service Regulators

Proportional Relief Valves

Series Way Ball Valve Threaded. SERIES 38 3-Way. Easy to Automate! See automated data sheets for pre-sized assemblies 38-TH-0025-XXX-T

BACK PRESSURE / SUSTAINING

Full Range Pressure Compensating Variable Flow Control

HIGH PRESSURE CONTROL VALVES

Buying more than 11 gauges? Call Lesman for additional discounts.

VESSEL & REACTOR VALVES. VS Series SPRAY & RINSE VALVES PROCESS VALVES

Type 4708 Supply Pressure Regulator

BACK PRESSURE / SUSTAINING

AWWA C504 COMPLIANT VALVES FROM 3 THRU 108

3-Way Decoking Valve Option - Installation and Operation Instructions Accessory G Background

61 Series Pilots for Pilot-Operated Pressure Reducing Regulators

KDV HIGH ACCURACY GLASS TUBE ROTAMETER

General. Rugged, Reliable with Value-added Features. Pipe Sizes. Temperature Limits. Spring Ranges. Buried Service. Increased Outlet Pipe Sizes

Porter Analytical & Industrial Products

A new concept in the storage of liquefied chemical and petrochemical gases Zero leakage Zero fugitive emissions

Propor tional Re lief Valve s

Medium Pressure Valves, Fittings and Tubing Pressures to 22,500 psi

Pressure Dump Valve Service Kit for Series 3000 Units

Laboratory Flowmeters

SC HYDRAULIC ENGINEERING CORPORATION

FLOW CONTROL & AIR PILOT SWITCH VALVES

1800CPB2 Pilot-Loaded Service Regulators

Instructions. Control Solution ICF 20-4, ICF 25-4, ICF ICF 40-4, ICF 20-6, ICF 25-6, ICF 32-6, ICF 40-6, Direction and position.

Transcription:

High Equipment Air Operated s High Equipment Company offers five lines of air operators to accommodate remote operation of pressure valves up to 00,000 psi. Various models of diaphragm and piston operated valves are available in both normally open and normally closed models, and can be controlled by air regulator, electrical solenoid or low pressure manual valve. The Remetco line of air operated metering valves provides remote operation for fine metering applications. Index Page Mini-Hippo Piston Air Operators...............7.. Hipco Diaphragm Air Operators..................7.2 Remarco Diaphragm Air Operators..................7. Hippo Piston Air Operators......7.. Remetco Piston Air Operated Fine Metering s..........7.4 R2 2/ 7.

High Equipment Mini-Hippo Piston Air Operators for Remote Operation To 6,000 psi Mini-Hippo Air Operators are available for both normally open service (spring to open/air to close) and for normally closed service (air to open/spring to close). These piston air operators provide remote automatic on/off operation of valves and can be controlled by means of an air regulator, an electrical solenoid, or a manual low pressure valve in the user s air supply line. Air inlet is NPT. Air pressure requirement ranges from 0 to 0 psi. The Mini-Hippo air operators may be supplied with the valves and operating pressures shown in table. To order simply specify catalog number of valve and type operation required. EXAMPLES: Mini-Hippo 0- (normally closed) Mini-Hippo 0-2AF6 (normally open) Mini-Hippo 0-AF4 (normally open/ normally closed) " Diameter Piston Air Operators (Spring To / Air To Close) AIr to Seat 0-**AF2 6,000 psi 0-**AF4 6,000 psi 0-**AF6 6,000 psi 0-** 6,000 psi 0-** 6,000 psi 0-**HF 6,000 psi Closed (Air To / Spring To Close) ** Standard Patterns (reference Page.4) Minimum Adjusting Air Air Screw to Unseat to Fully Torque 0-**AF4 6,000 psi in. lb. 0 psi 0-**AF6 6,000 psi in. lb. 0 psi 0-** 6,000 psi in. lb. 0 psi 0-** 6,000 psi in. lb. 0 psi 0-**HF 6,000 psi in. lb. 0 psi OPTIONS: Stems & Seats.... Carbide (for cyclic service)................ 7-4 (for cyclic service) Bodies..... Hastelloy C, Hastelloy B................ Inconel 600, Inconel 62................ Incoloy 800, Incoloy 82................ Titanium Grade 2, Titanium 6AL4V................ Nickel................ Monel Temperature Considerations.... Extended stuffing box for................ temperatures from -42 F................ to,200 F (medium and high................ pressure connections only) Closed 7.. R4 2/02

Hipco Diaphragm Air Operators for Remote Operation To Hipco Air Operators are available for both normally open service (spring to open/air to close) and for normally closed service (air to open/spring to close). These diaphragm air operators provide remote automatic on/off operation of valves and can be controlled by means of an air regulator, an electrical solenoid, or a manual low pressure valve in the user s air supply line. Air inlet is NPT. The Hipco air operators may be supplied with the valves and operating pressures shown in table. To order simply specify catalog number of valve and type operation required. EXAMPLES: Hipco 0- (normally closed) Hipco 0-2NFB (normally open) Hipco 0-AF4 (normally open/normally closed) OPTIONS: Stems & Seats.... Carbide (for cyclic service)................ 7-4 (for cyclic service) Bodies..... Hastelloy C, Hastelloy B................ Inconel 600, Inconel 62................ Incoloy 800, Incoloy 82................ Titanium Grade 2,.............. Titanium 6AL4V................ Nickel................ Monel Temperature Considerations.... Extended stuffing box for................ temperatures from -42 F to................,200 F (medium and high................ pressure connections only) 6 7 Diameter Diaphragm Air Operators Closed Air Operated s (Spring To / Air To Close) AIr to Seat 0-**AF4 0,000 psi 0-**AF6 0,000 psi 0-**NFA 0,000 psi 0-**NFB 0,000 psi 0-**NFC 0,000 psi F-**NFA,000 psi 8 psi F-**NFB,000 psi 8 psi F-**NFC 0,000 psi 00 psi F-**NFD 0,000 psi 00 psi 20-**LF4 20-**LF6,000 psi 8 psi 20-**LF 0,000 psi 00 psi 0-** 0-** 8 psi 0-**HF 8 psi 40-**HF 8 psi 60-** 60-** 60-**HF Closed (Air To / Spring To Close) Minimum Adjusting Air Air Screw to Unseat to Fully Torque 0-**AF4 0,000 psi 20 in. lb. 0 psi 4 psi 0-**AF6 0,000 psi 20 in. lb. 0 psi 4 psi 0-**NFA 0,000 psi 20 in. lb. 0 psi 4 psi 0-**NFB 0,000 psi 20 in. lb. 0 psi 4 psi 0-**NFC 0,000 psi 20 in. lb. 0 psi 4 psi F-**NFA,000 psi 60 in. lb. 80 psi 00 psi F-**NFB,000 psi 60 in. lb. 80 psi 00 psi F-**NFC 0,000 psi 7 in. lb. psi 00 psi F-**NFD 0,000 psi 7 in. lb. psi 00 psi 20-**LF4 40 in. lb. 0 psi 20-**LF6,000 psi 60 in. lb. 80 psi 00 psi 20-**LF 0,000 psi 7 in. lb. psi 00 psi 0-** 40 in. lb. 0-** 60 in. lb. 80 psi 00 psi 0-**HF 60 in. lb. 80 psi 00 psi 40-**HF 60 in. lb. 80 psi 00 psi 60-** 0 in. lb. 8 psi 60-** 0 in. lb. 8 psi 60-**HF 0 in. lb. 8 psi ** Standard Patterns (reference Page.4) High Equipment Company R4 2/02 2 W. 7th Street Erie, PA 60 U.S.A. Phone: (84) 88-2028 -800-28-7447 Fax: (84) 88-607 Website: www.high.com 7.2

High Equipment Remarco Diaphragm Operated s for Remote Operation To 00,000 psi Remarco air operated valves are available for both normally open service (spring to open/air to close) and for normally closed service (air to open/spring to close). These diaphragm operated valves provide remote operation up to 00,000 psi by means of an air input supply ranging from 2 to 0 psi to the air actuator. An electrical solenoid valve for the air supply is provided with all Remarco valves and is mounted directly to the valve. The standard solenoid is 20 volt, 60 cycle, watts with NPT air inlet. (Other voltages available at additional charge consult factory). The solenoid is normally closed and when energized allows air into the diaphragm casing to activate the valve. In the event of an electrical or air line failure, the valve will return to its normal position. The Remarco valve features removable stem seats. bodies are 6 stainless steel. stems are hardened 7-4PH stainless steel up to. Tool steel stems are standard on 00,000 psi valves. Standard packing on the and Remarco valves is Teflon O-ring with Buna-N, Viton, or Silicone, available at no additional cost. 7 Diameter Diaphragm Air Operators (Spring To / Air To Close) D0R2LFR D20R2LFR D0R2R D0R2R D0R2HFR D0R2HFR D60R2R D60R2R D60R2HFR D00R2XF4R D00R2XF6R 0,000 psi 0,000 psi 00,000 psi 00,000 psi 0 psi 0 psi Closed (Air To / Spring To Close) SD0R2LFR SD20R2LFR SD0R2R SD0R2R SD0R2HFR SD0R2HFR SD60R2R SD60R2R SD60R2HFR SD00R2XF4R SD00R2XF6R 0,000 psi 0,000 psi 00,000 psi 00,000 psi 40 ft. lb. 0 ft. lb. 0 ft. lb. 8 psi 8 psi 0 psi 0 psi 0 psi 00 psi 00 psi /6" /6" /6" /6" /6" /6" /6" /6" /6" /6" LF LF HF HF HF XF4 XF6 LF LF HF HF HF XF4 XF6 /6" /6" /6" /6" /6" /6" /6" /6" /6" /6" /6" /6".08" Tubing Connections Air Orifice to Seat O.D. I.D. Tubing Lock Nut Air Air Connections Torque to Unseat to Fully Orifice Setting O.D. I.D. OPTIONS: /6" /6" /6" /6" /6" /6" /6" /6".08" Stems & Seats.... Carbide (for cyclic service) Bodies..... MPN water service 00K valve................ Hastelloy C, Hastelloy B................ Inconel 600, Inconel 62................ Incoloy 800, Incoloy 82................ Titanium Grade 2, Titanium 6AL4V................ Nickel, Monel /6" /6" /6" /6" /6" /6" Closed 7. R6 /4

Hippo Piston Air Operators for Remote Operation To Hippo Piston Air Operators are available for both normally open service (spring to open/air to close) and for normally closed service (air to open/spring to close). These piston air operators provide remote automatic on/off operation of valves and can be controlled by means of an air regulator, an electrical solenoid, or a manual low pressure valve in the user s air supply line. Air inlet is NPT. Air pressure requirement ranges from to 20 psi. These operators may be supplied with the valves and operating pressures shown in table. Closed (Air To / Spring To Close) Medium Duty 0-**AF4 0-**AF6 F-**NFA F-**NFB F-**NFC F-**NFD 20-**LF4 20-**LF6 20-**LF 0-** 0-** 0-**HF 60-** 60-** 60-**HF Heavy Duty 0,000 psi 0,000 psi,000 psi,000 psi 0,000 psi 0,000 psi 0,000 psi F-**NFC,000 psi F-**NFD,000 psi 20-**LF4 20-**LF6 20-**LF 6,000 psi 20-**LF2,000 psi 20-**LF6 6,000 psi 0-** 0-** 0-**HF 60-** 60-** 60-**HF Extra Heavy Duty 20-**LF2 0-**NFF 0,000 psi 0-**NFH 0,000 psi 0-**LF6 0,000 psi 20-**LF6 0-** Orifice /64" /64" /6" /6" /64" /6" /2" /6" /6" /6" /6" /6" /64" /6" 7/6" /6" /2" /6" /6" /6" 7/6" /6" /6" /6" /6" 7/6" Minimum Adjusting Screw Torque 2 in.lb. 2 in.lb. 4 in.lb. 4 in.lb. 8 in.lb. 8 in.lb. 60 in.lb. 8 in.lb. 8 in.lb. 8 in.lb. 60 ft.lb. 7 ft.lb. 7 ft.lb. 7 ft.lb. ft.lb. 0 ft.lb. Air to Unseat 0 psi 0 psi 0 psi 0 psi 0 psi 2 psi 2 psi 2 psi 4 psi 4 psi 4 psi Air to Fully psi psi psi psi psi psi 8 psi Part Number Suffix E E E E E E Air Operated s To order simply specify catalog number of valve and appropriate suffix of operator required. EXAMPLES:....Hippo 20-LF4-............(normally closed)............hippo 20-2LF6-............(normally open) OPTIONS:...... Stems & Seat...Carbide, ceramic or Stellite............(for cyclic service) Bodies....Hastelloy C, Hastelloy B............Inconel 600, Inconel 62............Incoloy 800, Incoloy 82............Titanium Grade 2, Titanium 6AL4V............Nickel............Monel Packing........PolyPak Temperature.... Consideration...Extended stuffing box for............temperatures from -42 F............to,200 F (medium and high............pressure connections only) (Spring To / Air To Close) Medium Duty 0-**AF4 0,000 psi 0-**AF6 0,000 psi F-**NFA,000 psi F-**NFB,000 psi F-**NFC 0,000 psi F-**NFD 0,000 psi 20-**LF4 20-**LF6 20-**LF 0,000 psi 20-**LF2 6,000 psi 0-** 0-** 0-**HF 60-** 60-** 60-**HF Heavy Duty F-**NFC F-**NFD 20-**LF4 20-**LF6 20-**LF 20-**LF2 20-**LF6 0-** 0-** 0-**HF 60-** 60-** 60-**HF 8,800 psi,000 psi,000 psi,000 psi 8,800 psi Air to Seat 00 psi 00 psi psi 00 psi 00 psi 00 psi Extra Heavy Duty 20-**LF2 7/6" 0-**NFF 0,000 psi /6" 4 psi 0-**NFH 0,000 psi /6" 4 psi 0-**LF6 0,000 psi /6" 4 psi 20-**LF6 /6" 0-**LF6 7/6" ** Standard Patterns (reference Page.4) Part Number Suffix High Equipment Company R7 / 2 W. 7th Street Erie, PA 60 U.S.A. Phone: (84) 88-2028 -800-28-7447 Fax: (84) 88-607 Website: www.high.com Orifice /64" /64" /6" /6" /64" /6" 7/6" /2" /6" /6" /6" /6" /6" /64" /6" 7/6" /6" /2" /6" /6" /6" psi 00 psi 00 psi 0 psi 0 psi 0 psi E E E E E E 7..

High Equipment Remetco Piston Operated Fine Metering s For Liquids or Gases Precise control with fast response is possible in fine metering applications to with Remetco s. Pinpoint accuracy and repeatability are assured by a unique stem travel control device working in concert with a Conoflow operator, which is actuated by an input air pressure on only psi. Body material is Type 6 stainless steel, with both stem and removable seat of 7-4PH. The stem tip is ground to a included taper, withorifice sizes as listed in the ordering table. Installation requires only connection to an air supply of 20 to 00 psi. This is connected both to the supply air connection and to the instrument air inlet. The latter is regulated between and psi to actuate the valve to the desired position. Regulation is effected by the user s instrument or by the optional instrument panel at lower left. Thus the valve is in its full open position with a psi air input and in the closed position with a psi air input. Failsafe operation. In standard configuration, the valve OPENS upon failure of the air supply. It may also be supplied to close upon air failure, to open upon an increase in air signal, or any combination of these specifications. Remote Positioner RVP. Optional instrument panel shown at bottom can be ordered as an accessory. It is a manually operated remote air signal valve positioner which permits positioning the stem at any desired point within the travel of the stem. The dial indicator is graduated into 00 increments; thus each dial increment moves the stem 0.02". Standard inlet and outlet connections to the Remetco are for /6" OD coned and threaded tubing. Adapters may be supplied for other tubing sizes upon request. Shutoff not recommended. While this valve is capable of on-off operation, it is designed as a fine metering instrument. To assure maximum stem life, a manual on-off valve should be used in the line upstream of the Remetco. To order, use assembly number in table and specify if operation is to be other than the standard closure upon air failure. Add RVP as suffix if remote air signal valve positioner is desired. Ordering Table Assembly Orifice Number Rating CV 0M-2HFR 0,000 psi.2 0M-2HFR 0.22 60M-2HFR /6" 0.6 OPTIONS: Stems & Seats.... Carbide (for cyclic service) Bodies..... Hastelloy-C, Hastelloy B................ Inconel 600, Inconel 62................ Incoloy 800, Incoloy 82................ Titanium Grade 2, Titanium GAL4V................ Nickel................ Monel 7" 22" Remote Stem Positioner RVP above permits remote positioning of valve stem in increments of 0.02". To order, add suffix RVP to base order number. 7.4 R /4