speed monitor swe-compact

Similar documents
Components for Pull Rope Systems. Leaflet No. Kiepe 680

CONDUCTIVITY POINT/S LEVEL SWITCH JAYCEEAQUA 4000 SERIES

Installation, operating and maintenance Instructions for Seemag bypass level indicator

Position switches FP series

Prewired position switches FA series

safety Shut-Off Valve HON 721

Pull-rope emergency stop switch Type HENEX and SEGEX OPERATING INSTRUCTIONS

C-Flow Coriolis Mass Flow Meters

The Limit Switch with Better Seal, Shock Resistance, and Strength. General-purpose Limit Switch. Model Number Structure

Pressure switch and Thermostat CAS

Data sheet Pressure switch type CS December 2001 DKACT.PD.P10.A B1119

QPL... Pressure Switches. Siemens Building Technologies HVAC Products

Flow Sensors & Hydrometers Specification Sheet

Safety Shut-Off Valve HON 720

Simple Set Max. Pressure Independent Control Valves 2 Way 2-1/ /09/18

Pressure switches for air and water CS

Electromechanical pressure switches

Gas Pressure Regulator HON 502

INSTRUCTION MANUAL Pressure Relief Device LPT

FRM. Medium Pressure Regulator. Medium pressure regulator Type FRM

[Instruments for vacuum measurement, checking and adjustment] 3

Liquid ring vacuum pumps in compact design

Pressure switch KP-E. Data sheet

Pilot HON 625. Entwurf. Product information. serving the gas industry worldwide

Compact pressure switches for gas and air

Tightness controls TC 1 3 and TC 4

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

Page - CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 ITEM QUANTITY FOR MODEL 302

Note: the lock-out circuit must be in accordance with Section 8.7 of DIN/VDE Twin thermostats ATH.-SW-2020 ATH.-SW-2070 ATH.

Ultrasonic level transmitter and indicator

Pressure Transmitters 36 F-27839

4/2 way Pneumatic Solenoid Valve

Differential pressure switch / Lube oil protection control MP 54 and MP 55

Pressure transmitters EMP 2

NEW TYPE M PRESSURE RELIEF DEVICE

Gas Pressure Regulator HON 200

safety shut-off Valve HON 703 / HON 704

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073

Directional Control Valves Series VA13 and VA15 3- and 5-port valves, G1/8

SPD310/SPD360 Air Differential

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

Liquid ring vacuum pumps in compact design

Model NDA Differential pressure transmitter. Deltapi N Series A complete range of pneumatic pressure transmitters

Level transmitters and indicators Series LU Ultrasonic level transmitter and indicator for liquids and solids

HAYWARD FLOW CONTROL TFS SERIES FLOW METER INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

FLAMMABLE GAS SENSOR/TRANSMITTER

Pressure independent control valve (PICV) FLOWMATIC

Plankton pump Model ,2 KWatt. Manual. KC Denmark. Research Equipment Limnology Oceanography Hydrobiology

Pressure controls for hydro carbons, zone II applications, Type KPE

Series 44 Self-operated Pressure Regulators. Type 44-1 B Pressure Reducing Valve. Type 44-6 B Excess Pressure Valve

Installation, use and maintenance instructions. Gas burner (5)

P499 Heavy Duty Pressure Transducer

Instruction Manual Differential Pressure Transmitter

Chain Drives. 1. As no slip takes place during chain drive, hence perfect velocity ratio is obtained

Reset Volume Controller 2 Reversing Relay 3 Air Valve Actuator 4 Lower-of-Two-Pressures Relay 4 Diverting Relay 5 Higher-of-Two-Pressures Relay 5

EXH. Specifications. Descriptions. Min. working pressure MPa

Old documentation - Only for your information! Product is not available anymore!

Electronic Turbine Meter TERZ 94

Actuator HON 670 / 671

ECONORESS ELECTRONIC EPS & EPT - ENHANCED PRESSURISATION SET INSTALLATION OPERATION & MAINTENANCE DOCUMENTATION

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units

Miniature flowmeters DK 46, DKR 46 DK 47, DK 48, DK 800

Sprocket Selection Guidelines

Differential pressure controls/ Lube oil protection controls MP 54 and MP 55 REFRIGERATION AND AIR CONDITIONING. Technical leafl et

Pressure control, differental pressure control and thermostat Type RT

ELECTRIC ACTUATORS for continuous underwater use

XMPA12B2142 pressure sensor XMP - 12 bar - G 1/4 female - 2 NC - without control type

Pressure Switches Application Guideline

Measurement of Low GAS & Liquid Flows

RMG Meßtechnik GmbH. Publication No E

Prewired position switches FA series

Electromechanical pressure switches

RP series Rotor Pumps

Series 44 Self-operated Pressure Regulators. Type 44-0 B Pressure Reducing Valve. ANSI version

Pressure switch Type BCP

SSV-Actuator HON 673 (K 1a, K 2a)

Level transmitter LT 100

References 6 k thermal overload relays, adjustable from 0.11 to 16 A

Pressure switch, Differential pressure switch and Thermostat RT-E

Series 44 Self-operated Pressure Regulators. Type 44-1 B Pressure Reducing Valve. Type 44-6 B Excess Pressure Valve. ANSI version

Mechanical Pressure Measurement

1 LS unloading (control valve, orifice, none) 2 LS max pressure relief. 3 Spool type

SPECIFICATIONS ATTENTION

Model 130M Pneumatic Controller

Liquid ring vacuum pumps single-stage

SSR. Smart Valve Positioner.

Mechanical Pressure Switches for overpressure, vacuum pressure and differential pressure

Gas Pressure Regulator HON 300

Hydrostatic. Continuous level measurement. Overview Page 188 VEGAWELL 52 Page 190 VEGABAR 86, 87 Page 192 Accessory Page 196 AL-EN

Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

Differential pressure controls, Type MP 54, 55 and 55A

Mechanical Pressure Switches for overpressure, vacuum pressure and differential pressure

Installation and Operation Manual

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

VACUUM REGULATORS CONTENTS

k valve 2 (50)HF 2½ (65)SF installation guide aylesbury For valve sizes (DN): tel fax

Parts Manual STRIKER Striker 2840 Parts List - PN Printed in USA 03/18/08

Air Differentail Pressure Switch

TECHNICAL INFORMATION

Transcription:

speed monitor swe-compact opto-electronic leaflet no. Kiepe 114

general The electronic rotational speed monitor SWE-compact comprises constructively the opto-electronic pulse transducer, the speed analysing relay and the power supply in one unit. By this compact form of construction, the connecting wires between the pulse transducer and the analysing relay which are susceptible to interferences considering the usual electronic speed monitoring systems, are eliminated. Only the supply voltage as well as the cables for the voltage-free output relay contacts need to be connected to the SWE-compact. Electronic rotational monitoring of underspeed, control of slip, stand-still monitoring. installation and operation The unit has a separate chamber containing the connection terminals, the knob of the setpoint potentiometer, the LED as well as the knob of the start-up delay potentiometer. If the drive speed exceeds the pre-set operating speed, the relay is energized and the LED is lit. If the drive speed falls below the pre-set operating speed, the relay drops. The LED is extinguished. An opto-coupler can be provided instead of the output relais. The SWE-compact has the same fixing dimensions as the approved devices type SWS, DKS and EOGS. All the couplings and accessoires of the devices can be used. For conveyors, speed monitoring can be effected directly from the conveyor by means of the SWE-compact with coupled conveyor monitor stand and belt drive B. Decisive features of the SWE-compact are: Entirely free of maintenance, interference proof transmission of signals even over extremely long distances, simple and costsaving setting up, monitoring of lowest rotating speeds (stand-still monitoring) and, above all, its compact construction especially planned for the operation under very rough service conditions. Technical data Device complies with EN 60204 EN 50178-94 EN 50081-1 EN 50082-2 Supply voltage 230 V ± 10%, 50 60 Hz (other voltages on request) Reset differential * 20% from cut-out speed to cut-in speed Trip point accuracy ~ 2 % Start-up delay 0,5 15 sec., adjustable Pick-up time Of the output relay is 200 ms after the cut-in of the actuating supply voltage Ambiente temperature - 20 C... + 70 C Mounting position Any Protection IP 65 according to EN 60529 Cable entry 2 x M25 x 1,5 Housing material Aluminium alloy GK-AISi 12 Output contact Single pole changeover goldplated contacts Contact ratings I e / U e 2 A / AC 230 V speed selection Type Number of Imp. / Rev. Range of set point adjustment rpm Cut-out delay sec. SWE 001 1 40-600 2,5-1,1 SWE 005 5 8-120 2,5-1,1 SWE 010 10 4-60 2,5-1,1 SWE 025 25 1,6-24 2,5-1,1 When used in conjunction with the conveyor monitor type B the operating speed can be converted into rpm by the following formulae: belt speed in meters/ sec. x 60 = rev. / min. 0,314

Couplings 8 4 M8 Driving shaft 28 23 K 1 ~60 50 20 SWE 10 40 Ordering code: 94.040 535.001 Flexible plastic coupling, temperature range about - 25 C to + 100 C, weatherproof, maximum misalignment 3 mm 1) Connection shaft 2) Coupling 3) M 5 x 6 Grub screw 4) 8,4 Locking washer K 6 SWE 15 4 28 22 10 25 Ordering code: 94.040 535.002 Two-pin rubber coupling, oil-resistant, maximum misalignment 2 mm 1) Coupling 2) Roll pin 4 x 20 Driving shaft 10 +1 2,8 12 10 h9 K 7 M8 Driving shaft 28 23 ~64 ~62 10 40 SWE Ordering code: 94.040 535.004 Flexible bellows coupling suitable for poor misalignment, maximum misalignment 10 mm 1) Bellows 2) Fixing collar 3) M 5 x 6 Grub screw 4) Hexagon headed M 8 x 30 screw 5) Spring retaining ring B 8 6) Retaining strap connection diagram SWE (cover replaced) Anlaufüberbrückung Schaltpunkteinstellung Start up delay Setpoint adjustment 230 V 50 60 Hz A 1 A 2 16 15 18

mouniting details & Ordering codes Rotational Speed Monitor SWE compact 1 106 5 10 h9 4 15 3 101 20 1 SWE - 2 1a SWE - 2 / - / K 1 1b SWE - 3 / - / K 6 1c SWE - 2 / - / K 7 80 H8 Rotational Speed Monitor SWE compact with foot mounting bracket F 4 5 110 30 109 90 K 1 K 6 K 7 90 53 1a 1b 27 M 6 155 127 1c ~64 K 1 K 6 K 7 46 19 2a 2b 2c ~166 ~57 2 75 127 Pg 16 12,5 45 104 9 8 156 129 ~167 2 SWE - 2 / F 4 2a SWE - 2 / F 4 / K 1 2b SWE - 3 / F 4 / K 6 2c SWE - 2 / F 4 / K 7 Rotational Speed Monitor SWE compact with mounting flange F 1 K 1 K 6 K 7 2 110 5 120 3a 3b 47 19 3c ~58 3 80 70 6,6 155 129 ~166 3 SWE - 2 / F 1 3a SWE - 2 / F 1 / K 1 3b SWE - 3 / F 1 / K 6 3c SWE - 2 / F 1 / K 7 Rotational Speed Monitor SWE compact with mounting flange F 2 5 68 120 8 2 30 3 6,6 K 1 K 6 4a 6 4b 40 4 100 H8 90 106 4 SWE - 2 / F 2 4a SWE - 2 / F 2 / K 1 4b SWE - 3 / F 2 / K 6 170 170

dimensions and ordering codes Conveyor Drive Model sweb Type Number Housing (IP 65) 1) Roller 2) 1) S: Aluminium 2) G: Rubber, K: Plastic dimensions Hinge Pedestal Type GB to be fitted on Belt Drive B 8 21 78 44 110 86 80 105 100 39 11 101 70 16 235 406 50 80 104 32 95 ~148 12 M10 80 3 10 35 79 19 3 Rubber-bonded metal Type G Adjusting screw Material: Cast iron Type K The use of the hinge pedestal is recommended to ensure constant pressure between belt and roller in order to avoid failures caused by slip. The extent of supply of the belt drive comprises rubber or plastic rollers. Subject to change without notice.

Vossloh Kiepe GmbH D-40599 Düsseldorf (Germany) Kiepe-Platz 1 Phone +49 (0) 211 74 97-0 Fax +49 (0) 211 74 97-420 info@kiepe-elektrik.com www.kiepe-elektrik.com 114/2 02/09