Raising the bar. Philips Advance Optanium high efficiency instant start T8 ballasts have set new standards for maximizing energy savings

Similar documents
DRIVER VOLTAGE DRIVER TYPE. DM v Low Voltage Dimming (10% - 100%) (Standard) LV - Line Voltage Dimming *Specify Voltage (120v or 277v)

DRIVER VOLTAGE DRIVER TYPE. DM v Low Voltage Dimming (10% - 100%) (Standard) LV - Line Voltage Dimming *Specify Voltage (120v or 277v)

ELECTRONIC FLUORESCENT BALLASTS

Watts. xppower.com. Input. General. Environmental. Output. EMC & Safety. Output Voltages from 2.5 V to 48 V. Non-standard Outputs Available

LED Modules. Fortimo LED Line High Flux PR. 2ft 4000lm 1R NA

LED T8 U-BEND DIRECTFIT PLASTIC SERIES UL TYPE-A

DCS Series 1 kw, 1.2 kw, & 3 kw

ASSE International Product (Seal) Listing Program

To provide loyalty, quality, and innovation to our. customers. We are Amp Audio

Advanced Test Equipment Rentals ATEC (2832)

DESIGN ENVELOPE 6800 G 1 DUTY PUMP

Photometric Test Report

SPECIFICATIONS ATTENTION

Verdi G-Series. High-Power Pumps for Ti:Sapphire Lasers and Amplifiers FEATURES

Table of Contents. Version 5.1. Mounting Hardware 9-10 Aluminum 9 Plastic 9 Plastic & Aluminum 10

HAI UPB 15A Relay Switch and Auxiliary Switch Installation and Operating Instructions

Verdi G-Series Family

FEATURES AND BENEFITS. Meets UL/EN/IEC , 4Th ed. For EMC*

P9000 DESCRIPTION. For parts requiring RoHS compliance, please contact factory. P February /6

For Models: 55A00-2 (HAI UPB 1500W Wall Switch Dimmer) 55A00-3 (HAI UPB 2400W Wall Switch Dimmer) 37A00-1 (HAI Auxiliary Switch)

HCI-T 70 W/942 NDL PB

HCI-T 70 W/942 NDL PB

Genesis MX SLM-Series

ECONORESS ELECTRONIC EPS & EPT - ENHANCED PRESSURISATION SET INSTALLATION OPERATION & MAINTENANCE DOCUMENTATION

HAI UPB Wall Switch and Auxiliary Switch Installation and Operating Instructions

User manual. PCA EXCEL one4all with corridorfunction PCA T5 ECO lp with corridorfunction TE one4all with corridorfunction

Tightness controls TC 1 3 and TC 4

Lighting Contactors. 4.1 UL Rated AC Contactors

VA Amps (24/115) A B C 230V 460V 24V 115V. Features: Designed for high in-rush applications High-grade silicon steel laminations

MODELS (2 foot Version) (4 foot Version)

kēlo LED Light Installation Instructions

QT-FIT8 2X58-70/ VS20

Presented to the IAPMO Standards Review Committee on March 7, 2016

OPERATION AND MAINTENANCE INSTRUCTION MANUAL

Single-Phase Pad-Mounted Distribution. Single-Phase Pad-Mounted Distribution Transformers KVA

URC Voltage Sensor SEN-VOLT for use with MRX units containing sensor ports

Efficient EMC Solutions

/50/100 Pair. Protected Entrance Terminals

Welcome to the World of In-Home Gardening! Simple Steps to Get Your AeroGarden Up and Growing (No Tools Required)

MP15 Jockey Pump Controller

TUV Low Pressure Mercury

LED LED Street Lamps. Industrial / Commercial LED "Corn" Lamps. 360 Beam Angle. Color 30=3000k 40=4000k 50=5000k 60=6000k.

Valve Proving System VDK 200 A S06*

Z, Y, and X PURGE INDICATORS / CONTROLLERS

Digital Melting Point Apparatus

Valve Proving System VDK 200 A S02

Modulating Valves for Atmospheric, Infrared, and Direct Fired Burners

Welcome to the World of In-Home Gardening! Simple Steps to Get Your AeroGarden Up and Growing (No Tools Required)

Turbine Flowmeters for Gas Applications

ATTACHMENT 2 REQUIREMENTS MILLE LACS ENERGY COOPERATIVE S SCHEDULE 3 DISTRIBUTED GENERATION INTERCONNECTION REQUIREMENTS TABLE OF CONTENTS.

CONTENTS TABLE OF MAIDA S HISTORY TERMINOLOGY & GENERAL SPECIFICATIONS. iii. LEAD CODES and TAPE & REEL STANDARD SERIES 1 HC SERIES 17

Eastwood Versa-Cut Plasma Cutting System

VLT 2000 Series. How to size your VLT

Automatic Valve Proving Control

ECP Series Explosionproof Enclosures for OEM Applications. Optimized design, extensive sizes, and fast lead times.

Streetlight intelligent light corn light floodlight tube panel light bulbs spotlight strip light copper wire bulkhead down light MAGNATECH LED

code: NEWS _EN s/p LED 2016 NEWS 02 -EN

mikrofill PRESSURISATION UNIT

UKAS calibration laboratory 8809 Temperature, pressure and electrical signals calibration guide

Golf Performance Monitors. PureContact Operating Guide. Version of 9

LPS Product Guide. LPS Series Nitrogen Generators. N2-GEN LPS TM - Layup Protection System Copyrighted All Rights Reserved

Simple Set. Pressure Independent Control Valves 2 Way 1/2-2

IMPORTANT SAFETY INSTRUCTIONS

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units

M/MR Modulating Valves TABLE OF CONTENTS DESCRIPTION SPECIFICATIONS. For Atmospheric, Infrared, and Direct Fired Burners

AIR CONDITIONERS WA14**W SERIES

Ground Fault Protection for Electrical Tools

Certificate of compliance

AN ISOLATED SMALL WIND TURBINE EMULATOR

LED 14W POLO BULKHEAD WITH MICROWAVE SENSOR

MOYNO FLUID DETECTION CONTROL SERVICE MANUAL. Section: ACCESSORIES. Page: 1 of 8 Date: May 1, 1998 GENERAL

O.K. Safety first CDN USA. Table of Contents. Approvals. Attention IFGC CSA UL ANSI NFPA

LED Tips & Tricks. PO Box 1949, Nelson 7040, New Zealand. Head Office, 53C Bolt Road, Nelson 7011, New Zealand

NOR-LAKE, INCORPORATED 727 Second Street Hudson, Wisconsin 54016

SKP Series SKP25 U.. Pressure Regulating Gas Valve Actuator with Safety Shut-off Function

400H HARDMOUNT AIR COMPRESSOR KIT PART NO H HARDMOUNT AIR COMPRESSOR KIT PART NO

Customer Responsibilities

WestCoastCustomsElectronics.com

WestCoastCustomsElectronics.com

CCT-7320/ROC-2313 Reverse Osmosis Controller

PumpAgents.com - Click here for Pricing/Ordering Nominal psi (bar) Cut-In Cut-Out

Basic & Controlled Atmosphere Glove Boxes

LED Lightsource-R High Bay - EU

CONTENT. Report No.: GZ R6. Page 2 of 17

AIR CONDITIONERS WA14 SERIES

ISO 4081 INTERNATIONAL STANDARD. Rubber hoses and tubing for cooling systems for internal-combustion engines Specification

LED Lightsource-R High Bay - EU

COMPRESSOR PACK SUCTION CONTROLLER TYPE: LP41x

F&J SPECIALTY PRODUCTS The nucleus of quality air monitoring programs

Hazardous Duty Explosion Proof, Three Phase, Blue Chip Severe Duty

Installation, Operation & Maintenance Instructions

Field Certification Certificate of Compliance

Unisys. Imagine it. Done. c Consulting. c Systems Integration. c Outsourcing. c Infrastructure. c Server Technology. Unisys NDP 30 and NDP 110

Series AM3T-VZ 3 Watt DC-DC Converter

Turbine Flowmeters for Gas Applications

DULUX L LUMILUX DE LUXE

L 100. Bubble-Tube Level System. Installation, Operation and Maintenance Instructions

OEM Manual MODEL 2305 ECONOMICAL DIGITAL SINGLE CYLINDER SCALE

INSTRUCTIONS FOR USE

Transcription:

Raising the bar Philips Advance Optanium high efficiency instant start T8 ballasts have set new standards for maximizing energy savings Philips Advance Optanium high-efficiency electronic ballasts are engineered to optimize lighting performance and maximize energy savings are now available in a 347V version. These ballasts provide an unparalleled package of features and benefits to support the wide variety of T8 fluorescent lamps in the market place. down to -20 F (with standard lamps). Light output variety and cold starting combine to make them ideal for just about any T8 fixture design and application. Optanium ballasts enable T8 lighting systems to reach their full potential and represent the industry s most comprehensive family of high-efficiency lighting solutions. These Optanium ballasts for T8 lamps are part of the NEMA Premium allast Program, meet Hydro Quebec and C Hydro energy efficiency requirements and meet CEE high performance T8 lighting system specifications. All of this makes these ballasts part of an overall high-efficiency lighting system that may help you meet codes you or your customers need to be in compliance. Optanium ballasts are optimized for a variety of applications. Optanium 347V ballasts are available in both a standard light output design and a low-watt design. These ballasts have cold-starting capability High-efficiency Promotes sustainability by consuming less input watts than standard efficiency electronic ballasts Striation Reduction Circuitry Reduces the potential for lamp striation typically seen when using energy saving lamps -20 F Temperature Cold starting for a range of indoor and outdoor applications

No. Of Lamps Volts Lamp Method allast Family Catalog Number Power ANSI (Watts) allast Factor Max.THD % Line Current (Amps) Min. Temp. ( F/ C) Dim. Wiring Diagram F17T8 (17W) Normal allast Factor 16 0.93 10 0.06-20/-29 36A 20 1.07 15 0.06 0 / -18 30 0.88 15 0.09 0 / -18 34 1.01 15 0.10-20/-29 44 0.92 15 0.13-20/-29 50 1.00 15 0.15 0/-18 4 347 IS Optanium 60 0.93 15 0.17 0/-18 F17T8 (17W) Low allast Factor GOPA-1P32-LW-SC 22 0.91 10 0.07-20/-29 GOPA-2P32-LW-SC 27 1.05 10 0.08 0 / -18 GOPA-2P32-LW-SC 44 0.88 10 0.13 0 / -18 GOPA-3P32-LW-SC 48 1.01 10 0.14-20/-29 GOPA-3P32-LW-SC 63 0.90 10 0.18-20/-29 GOPA-4P32-LW-SC 70 0.96 10 0.20 0 / -18 4 347 IS Optanium GOPA-4P32-LW-SC 86 0.91 10 0.25 0 / -18 F25T8 (25W) Normal allast Factor 22 0.91 10 0.07-20/-29 27 1.05 10 0.08 0 / -18 44 0.88 10 0.13 0 / -18 48 1.01 10 0.14-20/-29 63 0.90 10 0.18-20/-29 70 0.96 10 0.20 0/-18 4 347 IS Optanium 86 0.91 10 0.25 0/-18 F25T8 (25W) Low allast Factor GOPA-1P32-LW-SC 20 0.80 10 0.07-20/-29 GOPA-2P32-LW-SC 24 0.88 10 0.08 0 / -18 GOPA-2P32-LW-SC 38 0.78 10 0.12 0 / -18 GOPA-3P32-LW-SC 42 0.85 10 0.12-20/-29 GOPA-3P32-LW-SC 56 0.77 10 0.16-20/-29 GOPA-4P32-LW-SC 62 0.81 10 0.18 0/-18 4 347 IS Optanium GOPA-4P32-LW-SC 74 0.79 10 0.22 0/-18 F32T8 (32W) Normal allast Factor 30 0.88 10 0.09-20/-29 34 1.03 10 0.10 0 / -18 54 0.88 10 0.16 0 / -18 63 1.00 10 0.18-20/-29 84 0.88 10 0.24-20/-29 89 0.96 10 0.26 0/-18 4 347 IS Optanium 107 0.88 10 0.31 0/-18 F32T8 (32W) Low allast Factor GOPA-1P32-LW-SC 26 0.77 10 0.08-20/-29 GOPA-2P32-LW-SC 31 0.88 10 0.09 0 / -18 GOPA-2P32-LW-SC 48 0.78 10 0.14 0 / -18 GOPA-3P32-LW-SC 55 0.86 10 0.16-20/-29 GOPA-3P32-LW-SC 74 0.77 10 0.21-20/-29 GOPA-4P32-LW-SC 77 0.81 10 0.23 0/-18 4 347 IS Optanium GOPA-4P32-LW-SC 92 0.77 10 0.27 0/-18 F32T8/ES (25W) Normal allast Factor 27 0.88 10 0.08 27 1.04 10 0.09 44 0.88 10 0.12 48 1.00 10 0.14

No. Of Lamps Volts Lamp Method allast Family Catalog Number Power ANSI (Watts) allast Factor Max.THD % Line Current (Amps) Min. Temp. ( F/ C) Dim. Wiring Diagram 0.88 10 0.19 74 0.95 10 0.21 4 347 IS Optanium 89 0.88 10 0.26 F32T8/ES (25W) Low allast Factor GOPA-1P32-LW-SC 21 0.77 10 0.06 GOPA-2P32-LW-SC 25 0.88 10 0.07 GOPA-2P32-LW-SC 39 0.78 10 0.12 GOPA-3P32-LW-SC 43 0.86 10 0.13 GOPA-3P32-LW-SC 58 0.77 10 0.17 GOPA-4P32-LW-SC 0.81 10 0.19 4 347 IS Optanium GOPA-4P32-LW-SC 78 0.78 10 0.22 F32T8/ES (28W) Normal allast Factor 25 0.88 10 0.07 29 1.04 10 0.09 47 0.88 10 0.14 52 1.00 10 0.16 70 0.88 10 0.20 79 0.97 10 0.23 4 347 IS Optanium 96 0.88 10 0.28 F32T8/ES (28W) Low allast Factor GOPA-1P32-LW-SC 22 0.77 10 0.07 GOPA-2P32-LW-SC 26 0.88 10 0.08 GOPA-2P32-LW-SC 42 0.78 10 0.12 GOPA-3P32-LW-SC 46 0.77 10 0.13 GOPA-3P32-LW-SC 62 0.77 10 0.18 GOPA-4P32-LW-SC 70 0.81 10 0.20 4 347 IS Optanium GOPA-4P32-LW-SC 84 0.78 10 0.24 F32T8/ES (30W) Normal allast Factor 23 0.88 10 0.06 32 1.04 10 0.10 51 0.88 10 0.15 57 1.00 10 0.17 76 0.88 10 0.22 84 0.95 10 0.25 4 347 IS Optanium 102 0.88 10 0.30 F32T8/ES (30W) Low allast Factor GOPA-1P32-LW-SC 24 0.77 10 0.07 GOPA-2P32-LW-SC 28 0.88 10 0.08 GOPA-2P32-LW-SC 46 0.78 10 0.13 GOPA-3P32-LW-SC 50 0.86 10 0.15 GOPA-3P32-LW-SC 67 0.77 10 0.19 GOPA-4P32-LW-SC 74 0.81 10 0.22 4 347 IS Optanium GOPA-4P32-LW-SC 89 0.78 10 0.26 F40T8 Normal allast Factor 42 1.02 10 0.12 32/00 75 1.00 10 0.22 32/00 113 0.93 10 0.28 32/00 F40T8 Low allast Factor 37 0.86 10 0.11 32/00 0.85 10 0.19 32/00 97 0.84 10 0.28 32/00

allast Specifications: Section I - Physical Characteristics 1.1 allast shall be physically interchangeable with standard magnetic or standard electronic ballasts, where applicable. 1.2 allast shall be provided with integral leads color-coded per ANSI C82.11. Section II - Performance Requirements 2.1 allast shall be Instant Start. 2.2 allast shall provide Independent Lamp Operation (ILO) for Instant Start ballasts allowing remaining lamp(s) to maintain full light output when one or more lamps fail. 2.3 allast shall contain auto restart circuitry in order to restart lamps without resetting power. 2.4 allast shall operate from 60 Hz input source of 347V as applicable with sustained variations of +/- 10% (voltage and frequency). 2.5 allast shall be high frequency electronic type and operate lamps at a frequency between 42kHz and 52kHz to avoid interference with infrared devices, eliminate visible flicker and avoid Article Surveillance System, such as anti-theft devices. 2.6 allast shall have a Power Factor greater than 0.98 for primary lamp. 2.7 allast shall have a minimum ballast factor for primary lamp application as follows: 0.77 for Low Watt and 0.88 for Normal Light Output. 2.8 allast shall provide for a Lamp Current Crest Factor of 1.7 or less in accordance with lamp manufacturer recommendations. 2.9 allast input current shall have Total Harmonic Distortion (THD) of less than 10% when operated at nominal line voltage with primary lamp. 2.10 allast shall have a Class A sound rating for all 4-foot lamps and smaller. 2.11 allast shall have a minimum starting temperature of 0F (-20 C) for standard lamps and 60F (16 C) for energy-saving T8 lamps. 2.12 allast shall tolerate sustained open circuit and short circuit output conditions. 2.13 allast shall have lamp striation-reduction circuitry. Section III - Regulatory Requirements 3.1 allast shall not contain any Polychlorinated iphenyl (PC). 3.2 allast shall be Underwriters Laboratories (UL) listed, Class P and Type 1 Outdoor; and Canadian Standards Association (CSA) certified where applicable. 3.3 allast shall comply with ANSI C62.41 Category A for Transient protection. 3.4 allast shall comply with ANSI C82.11 where applicable. 3.5 allast shall comply with the requirements of the Federal Communications Commission (FCC) rules and regulations, Title 47 CFR part 18, Non-Consumer (Class A) for EMI/RFI (conducted and radiated). 3.6 allast shall meet NEMA/CEE High Performance T8 Lighting System Specifications. Section IV - Other 4.1 allast shall be manufactured in a factory certified to ISO 9002 Quality System Standards. 4.2 allast shall carry a limited warranty from date of manufacture against defects in material or workmanship. This warranty is conditioned upon operation at a maximum case temperature of, among other items. (Go to our website for up-to-date warranty information, www.philips.com/advancewarranty). 4.3 Manufacturer shall have a twenty-year history of producing electronic ballasts for the North American market. 4.4 allast shall be Philips Advance part # or approved equal.

Wiring diagrams and Dimensions Diag. Diag. Diag. Diag. Setting industry standards for ballast efficiency As charter product in the NEMA Premium allast Program, Optanium ballasts are recognized as supporting energy-efficient lighting objectives. The National Electrical Manufacturers Association 9NEMA) has created this program to help lighting professionals and end users recognize the market s highest-performing ballast products. For more information on the NEMA Premium allast Program, As a license in the NEMA Premium allast Program, Philips Lightning Electronics has determined that these products meet the NEMA Premium specifications for premium energy efficiency.

2010 Philips Lighting Electronics N.A. All rights reserved. Form No. EL-2156-05/10 Philips Lighting Electronics 10275 W. Higgins Road Rosemont IL 60018 Tel: 800-322-2086 Fax: 888-423-1882 Customer Support/Customer Care: 800-372-3331 OEM Support: 866-915-5886 www.philips.com/advance