vacon nx ac drives hxm120 cooling unit, ss-piping commissioning and maintenance manual

Similar documents
vacon nx ac drives hxl040 cooling unit, ss-piping commissioning and maintenance manual

KTM 50 (DN ) Installation, maintenance and operating instructions

Pressure relief valve

Flowmeter. Original operating manual DFM

SonoMeter 30 Energy Meters

Pressure relief valve

Ball valve. Operating instructions for series. Version BA Print-No TR MA DE Rev001

Pressure relief valve DHV 712 DN 65-80: 0,5-10 bar, DN : 0,3-4 bar, DN 100: 0,5-6 bar

Pressure Reducing Valve DMV 750 set range: bar

Pressure Relief Valve DHV 718

Pneumatic proportional controller Types M Types FM Function tested for use of the float in Ex-zone 0

Size : Ends : Min Temperature : Max Temperature : Materials : Cast iron body

Differential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN

Connecting hoses. Type FS. Connecting hoses for the water-side connection of air- water systems and decentralised ventilation units PD FS 1

Installation and Operating Instructions Bypass Flow Meter DST

Engineering Data Sheet

Pressure relief valve DHV 716 set range: 0,5-10,0 bar

Size : Ends : Min Temperature : Max Temperature : Materials : Cast iron EN GJL 250 body. Reinforced lug for DN200 :

AVK SERIES 601, 602, 603 & 605 UNIVERSAL COUPLINGS, ADAPTORS & END CAPS INSTALLATION, OPERATION & MAINTENANCE MANUAL

Rotary valves HRB 3, HRB 4

Pressure relief valve DHV 725 set range: 0,2-10,0 bar

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

Pressure Reducing Valve DMV 755

Pressure Reducing Valve DMV 750

Pneumatic switch module 3/2-way valve (On/Off) Types P Types FP Function tested for use of the float in Ex-zone 0

SLEEVED PLUG VALVES 2-WAY

SLEEVED PLUG VALVES 2-WAY

Instructions. Control Solution ICF 20-4, ICF 25-4, ICF ICF 40-4, ICF 20-6, ICF 25-6, ICF 32-6, ICF 40-6, Direction and Position.

Installation, Operation and Maintenance Manual for Back Pressure Regulator

Installation and commissioning instructions 255 series and 256 series

OPERATING MANUAL. Contents. Bottom outlet ball valve Type ecoline

Ref GAS WAFER BUTTERFLY VALVE. Model/Ref:

Centrifugal Gas Separator ZGA. Operating Manual. Dimensions, weights and other technical data are subject to changes.

Installation, Operation and Maintenance Instructions for Direct Hot Water Storage Vessels

Instructions. Control Solution ICF 20-4, ICF 25-4, ICF ICF 40-4, ICF 20-6, ICF 25-6, ICF 32-6, ICF 40-6, Direction and position.

SITRANS F I Gardex. Flowmeter. SITRANS F I Intra/Prima. Flap Flowmeter. Contents. English. General 1. SITRANS F I Gardex 2. SITRANS F I Intra/Prima 3

Modular valve block. Operating manual Series MVB 100/200. Version BA EN Print-No TR MA DE Rev001

Pressure Reducing Valve DMV 755 set range: 1,0-9,0 bar

Model MTB-ASME Vertical Bladder Tanks

3-Way Pressure-Reducing Cartridge, Size 2 4

L21S/SR/ST Glass Level Gauges

VGG... VGF... VGH... Gas Valves. Building Technologies HVAC Products VGG... VGF... VGH...

Remeha Quinta Cascade guide

Flamco Flamco-Fill STA Flamco-Fill STM

Model MTB-ASME Vertical Bladder Tanks

Installation, Operation and Maintenance Instructions for Mild Steel Buffer Vessel

The valves are used in combination with AMV(E) 130/140, AMV(E) 130H/140H and AMV(E) 13 SU actuators. DN k VS

Horizontal Bladder Tanks

Armatures for analytical probes

Electro-Pneumatic Converter YT-940 SERIES

Two-port valves, male threaded, PN25

Differential pressure and flow controller (PN 16) AVPQ - return mounting, adjustable setting

VGG... VGF... VGH... Gas Valves. Siemens Building Technologies HVAC Products VGG... VGF... VGH...

Liquid level glasses, type LLG REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Differential pressure controller (PN 16) AHP - return mounting, adjustable setting

Steam Trap BK BK 212-ASME. Original Installation Instructions English

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

SV5 Safety Valve Installation and Maintenance Instructions

Brazed Heat Exchangers

B2KL: 6-way ball valve with male thread, PN 16

Size : Ends : Min Temperature : Max Temperature : Materials : Cast iron body

Vortex Flow Meter Wafer or Flange Connection. - Steam - Liquid - Gas

Gas Appliance Pressure Regulators with integrated gas filter. FRI/6 Series

Seated valves VRB 3, VRG 3

Gas powered stop valves, type GPLX REFRIGERATION AND AIR CONDITIONING. Technical leaflet

AVP-F. p setting range (bar) Code No. 003H6200

Technical Manual. Liquid Level Transmitter CT801-LB/S

INSTRUCTION MANUAL Pressure Relief Device LPT

Vacuum Saving Valve Series ZP2V How to Order ZP2V A5 03 Connection thread symbol for the pad Male thread connection Symbol Thread Applicable fixed ori

INDUSTRIAS IBAIONDO, HYDROPNEUMATIC TANKS

AVS32 Stainless Steel Air Vent for Steam Systems Installation and Maintenance Instructions

Model MTB-ASME Horizontal Bladder Tanks

GAS PRESSURE CONTROL UNIT TYPE 132

The affordable consumption counter for compressed air and gases R 3 /4 (DN 20)

The valves are used in combination with AMV(E) 130/140, AMV(E) 130H/140H and AMV(E) 13 SU actuators. DN k VS

Spiratec ST14, ST16 and ST17 Sensor Chambers and sensors

Supratec. von-drais-straße 7 D Simmern/Hunsrück Fon: +49 ( 67 61) Fax: +49 ( 67 61)

Installation, Operation and Maintenance Instructions Buffer Vessel OM006

Water Safety Shut-off Valve HON 790

Gas Pressure Switch for DMV safety shutoff valves

Vertical Bladder Tanks

Materials : Stainless steel ASTM A351 CF8M

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Type Type Differential Pressure Regulators (opening)

Combined Pressure / Vacuum Relief Valve KITO VD/o

OFFICINE OROBICHE S.p.A. 1/9

TANDEM MODULATOR FOR OUTLET GAS FLOW: STEPPED (836 TANDEM) - CONTINUOUS (837 TANDEM) SERVO-CONTROLLED PRESSURE REGULATOR

SCA Series Inverted Bucket Steam Traps

MUELLER. A A Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3.

Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange

Flamco Airfix D-E. Installation and operating instructions. 1999, Flamco eps

Gas Pressure Switch for DMV safety shutoff valves

Monitoring device NTS 30

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073

Variable Area Flow Meters. VS Series

Electrically Operated Pressure-Relief Cartridge, Size 10

Operating instructions - Translation of the original -

Instruction Manual SB02, SB03, SB04 All metal flow limiter

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S

Transcription:

vacon nx ac drives hxm120 cooling unit, ss-piping commissioning and maintenance manual

WARNING HOT SURFACE! NOTE

WARNING HOT SURFACE! NOTE

11571_uk

WARNING

! NOTE! NOTE

WARNING! NOTE

Secondary circuit inlet/outlet Additional piping between HX-unit and the main drives! NOTE

WARNING WARNING WARNING

WARNING

WARNING

WARNING

- - - - - - - -! NOTE! NOTE

measurement range "ran high range low range "L0" "2" 2 switching point temperature "SPt" "on" "off" (standard) actual switching point "12" "1" 2 1 "2" normally closed "n.c." normally open / normally closed "0-C" normally open "n.o." (standard) small hysteresis "h05" hysteresis "HuS" standard hysteresis "h10" 1 "3" 3 switching output "S0" switching poin "SP" actual switching point "123" "1" 2 3 1 "2" 3 1 2 "3"

Maximum ambient temperature +35 C Maximum ambient relative humidity 60% VACON LIQUID COOLED NX DRIVE HXM120 Secondary circuit maximum +23 C (28 C-5 C) Primary circuit minimum +28 C (26 C+2 C)

Maximum ambient temperature +40 C Maximum ambient relative humidity 80% VACON LIQUID COOLED NX DRIVE HXM120 Secondary circuit maximum +33 C (38 C-5 C) Primary circuit minimum +38 C (36 C+2 C)

Maximum ambient temperature +40 C Maximum ambient relative humidity 50% VACON LIQUID COOLED NX DRIVE HXM120 Secondary circuit maximum +25 C (30 C-5 C) Primary circuit minimum +30 C (28 C+2 C)

Relative humidity, % Maximum ambient temperature +30 C Maximum ambient relative humidity 95% VACON LIQUID COOLED NX DRIVE HXM120 Secondary circuit maximum +40 C Primary circuit minimum +45 C (40 C+5 C) Dew-Point chart for ambient temperatures between +10..+50 @ 1013 mbar 100 10 15 20 25 30 35 40 45 50 95 90 85 80 75 70 65 60 55 50 45 40 35 30 25 20 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 Primary circuit water temperature, C WARNING

WARNING

! NOTE WARNING

Sensor reading [%] HX_-120, pure water, B=1 70,0 60,0 50,0 40,0 30,0 20,0 10,0 0,0 120 160 200 240 280 320 360 Flow [L/min}

Sensor reading [%] Sensor reading [%] HX_-120, 20% glycol, B=1.35 50,0 45,0 40,0 35,0 30,0 25,0 20,0 15,0 10,0 5,0 0,0 120 160 200 240 280 320 360 Flow [L/min} 40,0 HX_-120, 40% glycol, B=1,82 35,0 30,0 25,0 20,0 15,0 10,0 5,0 0,0 120 160 200 240 280 320 360 Flow [L/min}

FACTOR B HX_-120 Glycol content factor B 2 1,9 1,8 1,7 1,6 1,5 1,4 1,3 1,2 1,1 1 0% 20% 40% GLYCOL CONTENT

Checking / adding the Air expansion vessel pre-pressure Nitrogen Changing the primary circuit liquid Monthly inspection Once a month Once a year Every 2 years Every 5 years x x x x

WARNING! NOTE WARNING HOT SURFACE

! NOTE

WARNING

F1. 83 OverTempA A T1 T16

F1. 86 LowTemp A T1 T16

F1. 82 InletPressLow A T1 T16

F1. 51 External Fault F F1 F12

Height (Depth) Width Depth (Width)

100% FLOW = 360 l/min Plate heat exchanger route Flow Bypass route Flow Pressure drop plate heat exchanger Pressure drop 3-way valve Total pressure drop 100% 360 l/min 0% 0 0.5 bar 1.83 bar 2.33 bar 75% 270 l/min 25% 90 l/min 0.25 bar 1.83 bar 2.08 bar 50% 180 l/min 50% 180 l/min 0.116 bar 1.83 bar 1.95 bar 25% 90 l/min 75% 270 l/min 0.03 bar 1.83 bar 1.86 bar 0% 0 100% 360 l/min - 1.83 bar 1.83 bar => Pressure drop varies between 1.83 bar 2.33 bar 75% FLOW = 270 l/min Plate heat exchanger route Flow Bypass route Flow Pressure drop plate heat exchanger Pressure drop 3-way valve Total pressure drop 75% 270 l/min 0% 0 0.25 bar 1.03 bar 1.28 bar 50% 180 l/min 25% 90 l/min 0.116 bar 1.03 bar 1.146 bar 25% 90 l/min 50% 180 l/min 0.03 bar 1.03 bar 1.06 bar 0% 0 75% 270 l/min - 1.03 bar 1.03 bar => Pressure drop varies between 1.03 bar 1.28 bar 50% FLOW = 180 l/min Plate heat exchanger route Flow Bypass route Flow Pressure drop plate heat exchanger Pressure drop 3-way valve Total pressure drop 50% 180 l/min 0% 0 0.116 bar 0.46 bar 0.58 bar 25% 90 l/min 25% 90 l/min 0.03 bar 0.46 bar 0.49 bar 0% 0 50% 180 l/min - 0.46 bar 0.46bar => Pressure drop varies between 0.46 bar 0.58 bar

100% FLOW = 360 l/min Plate heat exchanger route Flow Bypass route Flow Pressure drop plate heat exchanger Pressure drop 3-way valve Total pressure drop 100% 360 l/min 0% 0 0.5 bar 0.16 bar 0.66 bar 75% 270 l/min 25% 90 l/min 0.25 bar 0.16 bar 0.41 bar 50% 180 l/min 50% 180 l/min 0.116 bar 0.16 bar 0.28 bar 25% 90 l/min 75% 270 l/min 0.03 bar 0.16 bar 0.19 bar 0% 0 100% 360 l/min - 0.16 bar 0.16 bar => Pressure drop varies between 0.16 bar 0.82 bar 75% FLOW = 270 l/min Plate heat exchanger route Flow Bypass route Flow Pressure drop plate heat exchanger Pressure drop 3-way valve Total pressure drop 75% 270 l/min 0% 0 0.25 bar 0.11 bar 0.36 bar 50% 180 l/min 25% 90 l/min 0.116 bar 0.11 bar 0.23 bar 25% 90 l/min 50% 180 l/min 0.03 bar 0.11 bar 0.16 bar 0% 0 75% 270 l/min - 0.11 bar 0.11 bar => Pressure drop varies between 0.11 bar 0.47 bar 50% FLOW = 180 l/min Plate heat exchanger route Flow Bypass route Flow Pressure drop plate heat exchanger Pressure drop 3-way valve Total pressure drop 50% 180 l/min 0% 0 0.116 bar 0.04 bar 0.16 bar 25% 90 l/min 25% 90 l/min 0.03 bar 0.04 bar 0.07 bar 0% 0 50% 180 l/min - 0.04 bar 0.04 bar => Pressure drop varies between 0.04 bar 0.20 bar

Bolt tightening torque guidelines for metric flange connections with PP-V, PP-steel and PVC flanges Number of Nominal Pipe screws x thread Bolt tightening torque (Nm) diameter DN diameter d diameter Flat gasket up to max. pressure of 10 bar / 40 C Profile gasket up to max. pressure of 16 bar 15 20 4 x M12 10 10 10 20 25 4 x M12 10 10 10 25 32 4 x M12 15 10 10 32 40 4 x M16 20 15 15 40 50 4 x M16 25 15 15 50 63 4 x M16 35 20 20 65 75 4 x M16 50 25 25 80 90 8 x M16 30 15 15 O-ring up to max. pressure of 16 bar

Bolt tightening torque for flange connections with Tesnit BA-S gasket s=2mm Max. temperature +50 C, flange DIN2642 PN10 Nominal diameter DN Number of screws x thread diameter Bolt tightening torque (Nm) 8.8 (bolt material) 10.9 (bolt material) Min torque Max torque Min torque Max torque 25 4 x M12 79 96 79 143 32 4 x M16 127 233 127 344 40 4 x M16 160 233 160 344 50 4 x M16 201 233 201 344 65 4 x M16 269 344 80 8 x M16 330 344 Bolt tightening torque for flange connections with Tesnit BA-S gasket s=2mm Max. temperature +50 C, flange DIN2633 PN16 Nominal diameter DN Number of screws x thread diameter Bolt tightening torque (Nm) 8.8 (bolt material) 10.9 (bolt material) Min torque Max torque Min torque Max torque 25 4 x M12 82 96 82 143 32 4 x M16 131 233 131 344 40 4 x M16 166 233 166 344 50 4 x M16 208 233 208 344 65 4 x M16 279 344 80 8 x M16 171 233 171 344

www.danfoss.com Document ID: Vacon Ltd Member of the Danfoss Group Runsorintie 7 65380 Vaasa Finland DPD01308D Rev. D Sales code: DOC-INSNXHXM120+DLUK