E 084 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 80 l/min / 21.1 gpm

Similar documents
E 328 E 498 Tank top mounting Connection up to G1½ / -24 SAE and SAE 2 Nominal flow rate up to 600 l/min / gpm

E 328 E 498 Tank top mounting Connection up to G1½ and SAE 2 Nominal flow rate up to 600 l/min

E 158 E 198 E 248. Tank top mounting Connection up to G11 / 4 Nominal flow rate up to 250 l/min e d

E 212 E 222 Tank top mounting Connection up to G1¼ / -20 SAE Nominal flow rate up to 220 l/min / 58.1 gpm

E 094 E 103 E 143 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 135 l/min / 35.7 gpm

E 212 E 222 Tank top mounting Connection up to G1¼ Nominal flow rate up to 220 l/min

E 441 E 451 E 461 E 641 E 700 Tank mounting Nominal flow rate up to 800 l/min

D 042 D 062 In-line mounting Operating pressure up to 100 bar Nominal flow rate up to 90 l/min

Fixed Displacement Motor A4FM

Displacement 12, , Maximum flow rate (at 1450 rpm) bar.

VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10

Fixed Displacement Plug-In Motor A2FE

Pressure reducing valve, pilot operated, Model 3DR

Auxiliary valve QDS6 Sequence valve, 3-way. Catalogue (GB) (US) October 1998

Variable Displacement Double Pump A20VO. Series 1, for open circuits Axial piston - swashplate design, Back to back - design

Fixed Displacement Pump KFA for commercial vehicles in open circuits

MPS/MST SPIN - ON FILTER SUCTION - RETURN SERIES. Maximum working pressure 12 bar. Flow rates to 300 l/min

Change-Over Pressure Filter DFDK

Desiccant Air Breathers DBE. Section 3: TNK SCHROEDER INDUSTRIES ACCESSORIES 21

PLD 03 T A CASAPPA S.p.A.

Dual displacement motor A10VM Plug-in dual displacement motor A10VE for open and closed circuit applications

Pressure reducing valve, direct operated

Fixed Displacement Motor A4FM

Leak free Pipe Rupture Valve for Excavators

FIK In-Tank Filters FIK. Max Flow: 170 gpm (643 lpm) Working Pressures to: Rated Static Burst to: Flow Range to:

Check Valves. Pilot Operated Check Valves. Vickers. 4CG-10, 20 Series 4CS-03, 20 Series 4CT-06/10, 20 Series. Basic Characteristics.

Leak-Free Load-Control Valve SAE ½ psi flange

Pressure reducing valve, direct operated

DENISON HYDRAULICS vane pumps - single, double T6G - T67G - T6ZC

Pressure reducing valve, pilot operated

2-way flow control valve Model 2FRM 6

Copyright, 2005 GPM Hydraulic Consulting, Inc.

Logic Elements Screw-in Cartridge Valves Pressures to 290 bar (4200 psi) Flows to 303 l/min (80 USgpm)

Pressure relief valve, direct operated

Installation and commissioning instructions 255 series and 256 series

D e s c r i p t i o n

Cooler-Bypass Thermostat Valve, Size 16

Load Controls Screw In Cartridge Valves Pressures to 350 bar (5000 psi) Flows to 190 l/min (50 USgpm)

Standard Operating and Maintenance Instructions for Pumping System Model PS-90

Hydraulic Reliability & Preventive Maintenance Report

ALF400 to 900, ALT-5/-9

Compressed Air Conditioning Catalog Chapter I

Check valve hydraulically pilot operated

Electrically Operated Pressure-Relief Cartridge, Size 10

3-Way Safety Block DSV

Double Pilot Operated Cartridge Check Valve, Size 8

Hand pump type CH. Product documentation. 300 bar 8.3 cm 3 /stroke. Operating pressure p max : Displacement volume V max stroke :

Spin-On Filters SSF 24,25

Inverse Proportional Pressure-Relief Cartridge, Size 10

Inverse Prop. Pressure-Relief Cart., Size 2 4

Proper Pump Installation Practices

Directional Controls

SPM. Pressure Filters MEDIUM PRESSURE INLINE FILTER

PRESSURE SEQUENCE VALVE TYPE UZK

ALF400 to 900, ALT-5/-9

Two-stage valve type NE

Vickers. Flow Controls. Flow Controls FN, F(C)G, FRG. Released 6/94

Flow rates to 200 l/min

Proportional Pressure-Relief Cartridge Valve, Size 2...4

DENISON HYDRAULICS T6 industrial application

WK /2 WAY CARTRIDGE VALVE TYPE URZS 32 COVER FOR CARTRIDGE VALVE TYPE ULZS 32. Size 32 up to 42 MPa 700 dm 3 /min DESCRIPTION OF OPERATION

HIGH PRESSURE FILTERS DFDK Series Inline Duplex Filters 4568 psi up to 90 gpm

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

BACK PRESSURE / SUSTAINING

Pressure-Relief Cartridge Valve, Size 4

Directional Control Valves Technical Information Model 1500

ALF400 to 900, ALT-5/-9

Variable Displacement Pump A10VO

P2* MODULAR SUBPLATES FOR ISO (CETOP 03) VALVES

Allspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW. Tel +44 (0)

BACK PRESSURE / SUSTAINING

Flow Control Valves. 1 Description. 2 Symbols. Series MTKA, MTQA, MTCA 2.1 MTKA MTQA flow control valve. 1.1 MTKA flow control valve

Pressure reducing valve, direct operated, type DR 5 DP Huade América 1

BUTTERFLY VALVES. Toll Free (877) - ICFLUID -2-

Self-priming makes priming unnecessary Exhausts the air inside the suction pipe to suck up liquid. Air operated type.

3-Way Pressure-Reducing Cartridge, Size 2 4

TBV-CM. Combined control & balancing valves for small terminal units For modulating control NPT threads

D62 - D63 Directional Control Valve l/min

Auto Feed Lube, Auto Feed Tank ALF400 to 900, ALT-5/-9

GENO -Flushing Compressor Product Data Sheet F 02

BW0500AO. ByWire Elements BW0500AO Element 4/3 with side ports IBW0500 Interface

Pressure-limiting valve and pre-load valve type MVG, MVE and MVP

APPLICATION. Conveyors Metal working machines Machines for agriculture Road building machines Mining machinery Food industries

Monoblock Directional Control Valve RMB 202

Full Range Pressure Compensating Variable Flow Control

HYDRAULIC MOTORS MTM APPLICATION OPTIONS CONTENTS EXCELLENCE GENERAL

North American Simplex Basket Strainers for Gas and Oil

Prop. 3-Way Pressure-Reducing Cart., Size 5 / SAE 08

directional control valve series cv691

Technical Data Sheet TI-F50 Locking Units series KFH

LPK1230 Hydraulic Crimping Tool 12 ton

STAD-C. Balancing valves DN 15-50

Axial piston pumps type PVPY-C (-R, -L) variable displacement, with mechanical controls obsolete components - availability on request

4/3 Directional valve elements L8_P5 with proportional (ED-IP) control and with or without LS connections L8_P5 (ED-IP)

LMP 110 Maximum pressure 80 bar F l o w r a t e s t o l / m i n

Industrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US

INSTALLATION GUIDE MODEL NUMBER X. UniMaxx-Plus-SC-500-AC-V3 UNIMAXX SOLAR PUMP STATION

DEWATERING PUMP SOLUTIONS. Pneumatic pumps

LMP Filter element in according to DIN Style B. Style S. Maximum pressure 30 bar F l o w r a t e s t o l / m i n D.I. D.I.

Compressed Air Cleaning Filter Series

Transcription:

Return-Suction Filters E 08 Tank top mounting Connection up to G / -6 SE Nominal flow rate up to 80 l/min /. gpm Description pplication For operation in units with hydrostatic drives, when the return flow is under all operating conditions higher than the oil flow of the feed pump. Performance features Protection against wear: y means of filter elements that even in full-flow filtration meet the highest demands regarding cleanliness classes. Suction filter function: ecause of the 00%-filtration of the suction flow, no dirt can get into the feed pump. Return filter function: y means of full-flow filtration in the system return, the pumps above all are protected from dirt particles remaining in the system after assembly, repairs, or which are generated by wear or enter the system from outside. Return-Suction-Filter E 08 Page

Function (schematic): Functional characteristics The hydraulic oil returning from the circuit () passes the filter element (), is pressurized by a 0. bar / 7. psi check valve () and supplied to the feed pump (). The surplus oil flows filtered over the integral check valve into the reservoir. s the feed pump is always fed with pressurized oil, the risk of cavitation is minimized and full performance is available even during the critical cold start phase. n integral pressure relief valve () prevents too high back pressure and protects the shaft seals against damages. s this valve leads the oil directly into the tank there is no direct connection between the return line () and the connection of the feed pump () (no by-pass valve function). The emergency-suction valve () with µm protection strainer () supplies the feed pump in case of a short term of lack of oil. During normal operation, a lack of oil may definitely not occur (refer to Design section). Start-up / De-aeration For units with emergency-suction valve and protection strainer the start up set E 08.70 can be used to de-aerate the hydraulic system at first start up or at start-up after repair; hereby the immediate supply of the feed pump with hydraulic oil is guaranteed. For all other types, deaerating instructions published by the manufacturers of hydraulic drives must be observed. Filter maintenance y using a clogging indicator the correct moment for maintenance is indicated and guarantees therefore the optimum utilization of the filter elements. Emergency-suction (schematic) Filter elements Flow direction from center to the outside. The star-shaped pleating of the filter material results in: large filter surfaces low pressure drop high dirt-holding capacities long service life Dirt deposits are entirely removed when the element is changed and cannot re-enter the tank. ccessories Electrical and / or optical clogging indicators are available. Dimensions and technical data see catalog sheet 60.0. Page

Layout General In machines with a hydrostatic drive and combined working hydraulic system, return-suction filters replace the suction or pressure filters previously required for the feed pump of the closed-loop hydrostatic drive circuit as well as the return filter for the open-loop working hydraulic circuit. While each circuit operates independently with separate filters, the combination of the two circuits via the return-suction filter causes interaction between the circuits. If the design criteria described below are taken into account, you can take full advantage of the benefits provided by the return-suction filter concept, thus making sure that your system performs reliably even under extreme operating conditions. Required return flow in the system In order to maintain a pre-charge pressure of approx. 0. bar / 7. psi at the intake of the feed pump, the return flow must exceed the suction flow under any operating condition: Special feature: Versions with hole (Ø mm / 0.6 inch) in the pressurizing valve: at least 0 l/min /.6 gpm of excess flow Permitted feed pump flow rate at operating temperature (ν < 60 mm /s / 80 SUS, rpm=max): feed pump flow rate < 0. x rated return flow according to column of selection table at cold start-up (ν < 000 mm /s / 6 SUS, rpm = 000 min - ): feed pump flow rate < 0. x rated return flow according to column of selection table Please contact us if your system operates with higher flow rates than stated above. Flow velocity in the connecting lines Flow velocity in the return lines. m/s /.8 ft/s Flow velocity in the suction lines. m/s /.9 ft/s Permitted pressure in the suction lines t cold start up (ν < 000 mm /s / 6 SUS, rpm =.000 min - ): feed pump flow rate 0. x rated return flow. The pressure loss in the suction lines must not exceed 0. bar /.8 psi. Filter fineness grades With the filter fineness grades available, the following oil cleanliness according to ISO 06 can be achieved: 0EX: 8//... //7 6EX: 0/7/... 7//0 Even with the 6EX fineness grade, the requirements specified by manufacturers of hydrostatic drives are sometimes exceeded significantly. If components requiring a still better oil purity are used, we recommend the 0EX filter fineness grade. Suggested circuit layouts ) The leakage oil of the hydrostatic drive is routed across the filter. Drain oil to filter Working hydraulics The entire dirt produced in the hydrostatic drive by abrasion is filtered out immediately and is thus not taken in by the pump of the open-loop circuit. This circuit layout is always recommended if the return flow only slightly exceeds the suction flow, i.e. if there is a risk that the 0. bar / 7. psi pre-charge pressure cannot be maintained. ) The drain oil of the hydrostatic drive is not routed across the filter but is discharged directly into the tank. Working hydraulics P ackpressures in system return lines If drain oil from the hydrostatic drive is routed across the filter in addition to the flow of the open-loop circuit, the following has to be observed in order to protect the shaft seals: permitted leakage oil pressure for a given viscosity and speed (manufacturer s specifications!) pressure loss caused by the leakage oil pipes pressure loss caused by the oil cooler used backpressure of the filter for a given flow rate or kinematic viscosity (refer to pressure loss diagrams) Drain oil to tank P Depending on the application, the use of a cooler by-pass valve is recommended. Generously sized drain oil pipes are also of advantage. This circuit layout has the advantage that drain oil pressures are comparatively low. Page

Characteristics Nominal flow rate Up to 80 l/min /. gpm in return line (see Selection Chart, column ). Up to 0 l/min / 0.6 gpm feed pump flow rate (see Layout). The nominal flow rates indicated by RGO-HYTOS are based on the following features: closed by-pass valve at ν 00 mm /s / 97 SUS element service life > 000 operating hours at an average fluid contamination of 0.07 g per l/min / 0.7 g per gpm flow volume flow velocity in the return lines. m/s /.8 ft/s flow velocity in the suction lines. m/s /.9 ft/s Connection Threaded ports according to ISO 8 or DIN SE standard J. Sizes see Selection Chart, column 6 and 7 (other port threads on request). Filter fineness 0 µm(c)... 6 µm(c) ß-Werte nach ISO 6889 (see Selection Chart, column and diagram Dx). Dirt-holding capacity Values in g test dust ISO MTD according to ISO 6889 (see Selection Chart, column ). Hydraulic fluids Mineral oil and biodegradable fluids (HEES and HETG, see info-service 00.0). Temperature range -0 C... +00 C (temporary -0 C... +0 C) - F... + F (temporary -0 F... +8 F) Viscosity at nominal flow rate at operating temperature: ν < 60 mm /s / 80 SUS as starting viscosity: ν = 000 max mm /s / 6 SUS at initial operation: The recommended starting viscosity can be read from the diagram D (pressure drop as a function of the kinematic viscosity) as follows: Find the 70% p of the cracking pressure of the by-pass valve on the vertical axis. Draw a horizontal line so that it intersects the p curve at a point. Read this point on the horizontal axis for the viscosity. Operating pressure Max. 0 bar / psi Materials Screw-on cap: Filter head: Filter bowl: Seals: Filter media: Polyamide, GF-reinforced luminum alloy luminum alloy NR (FPM on request) EXPOR MX - inorganic multi-layer microfiber web Fitting position Standard type no restriction, preferably vertical Models with emergency-suction valve can vary up to from the vertical Models with hole mm / 0.6 inch in the check valve can vary up to from the vertical Even under unfavorable operating conditions (min. oil level, max. sloping) the oil outlet resp. emergency suction has to be below the oil level. Special designs are available for horizontal assembly. Page

Diagrams p-curves for complete filters in Selection Chart, column (0 % of the nominal flow volume via connection ) D Pressure drop as a function of the flow volume at ν = mm /s / 6 SUS (00/0 = casing empty without / with hole Ø mm / 0.6 inch) Q [gpm] 0. 0.6.8. 6..7.0,0 9.0 E 08 p [bar].,.0,0 0. 0, 0 0 0 0 0 60 80 00 0 Q [l/min].8. 7. p [psi] p [bar] Pressure drop as a function of the kinematic viscosity at nominal flow ν [SUS] 0 97 8 78 708 6 7. 0 00 00 600 800 000 ν [mm /s] 8.0. 9.0. p [psi] Filter fineness curves in Selection Chart, column Dx Filtration ratio β as a function of particle size x obtained by the Multi-Pass-Test according to ISO 6889 The abbreviations represent the following ß-values resp. finenesses: Filtration ratio β for particles > x µm Efficiency [%] For EXPOR MX and Paper elements: EX = β (c) = 00 EXPOR MX 7EX = β 7 (c) = 00 EXPOR MX 0EX = β 0 (c) = 00 EXPOR MX 6EX = β 6 (c) = 00 EXPOR MX 0P = β 0 (c) = 00 Paper ased on the structure of the filter media of the 0P paper elements, deviations from the printed curves are quite probable. For special applications, finenesses differing from these curves are also available by using special composed filter material. Particle size x [µm] (for particles larger than the given particle size x) Page

Selection Chart Part No. Nominal return flow rate Pressure drop see diagram D/curve no. Filter fineness see Diagr. Dx Connection Dirt-holding capacity Connection Cracking pressure of CV Cracking pressure of PRV Symbol Suction valve l/min g bar bar kg Replacement filter element Part No. Weight 6 7 8 9 0 E 08-6 7 D/ 0EX G G¾ 0..0 V.07-06.7 Remarks E 08-77 80 D/ 6EX G G¾ 0.. V.07-08.7 E 08-88 80 D/ 6EX G¾ G¾ 0.. V.07-08.7 E 08-78 80 D/ 6EX G G¾ 0.. V.07-08.7 - E 08-87 80 D/ 6EX G¾ G¾ 0.. V.07-08.7 - E 08-77 80 D/ 6EX G G¾ 0.. V.07-08.8 E 08-88 80 D/ 6EX G¾ G¾ 0.. V.07-08.8 E 08-87 80 D/ 6EX G G¾ 0.. V.07-08.8 +6 Preferred type, no minimum order quantity required Cracking pressure of check valve Cracking pressure of pressure relief valve With hole Ø mm / 0.6 inch in the check valve for oil drain when opening the filter cover With emergency-suction valve and protection strainer (mesh size µm) 6 Suitable for horizontal assembly ll filters are delivered with a plugged clogging indicator connection M x. (connection P ). s clogging indicators either manometers or electrical pressure switches can be used. For the appropriate clogging indicators see catalog sheet 60.0. Remarks: The start of the red area respectively the switching pressure of the electrical pressure switch has always to be lower than the cracking pressure of the pressure relief valve (see Selection Chart, column 9). Clogging indicators are optional and always delivered detached from the filter. The filters listed in this chart are standard filters. If modifications are required, e.g. for horizontal assembly or with integrated suction valve integrated into the pressure relief valve (see section symbols, symbol no. ) to guarantee the emergency steering feature for vehicles with official road use, we kindly ask for your request. For de-aeration a bleed screw (for connection P ) with Part No. SV 0. is available. Page 6

Selection Chart Part No. Nominal return flow rate Pressure drop see diagram D/curve no. Filter fineness see Diagr. Dx Connection Dirt-holding capacity Connection Cracking pressure of CV Cracking pressure of PRV Symbol Suction valve gpm g SE SE psi psi lbs Replacement filter element Part No. Weight 6 7 8 9 0 E 08-76 9.8 D/ 0EX -6-7. V.07-06.0 Remarks E 08-77. D/ 6EX -6-7. 6 V.07-08.8 6 E 08-78. D/ 6EX -6-7. 6 V.07-08.0 cracking pressure of check valve cracking pressure of pressure relief valve corresponds to /6 - UN corresponds to /6 - UN with emergency-suction valve and protection strainer (mesh size µm) 6 with hole Ø 0.6 inch / mm in the check valve for oil drain when opening the filter cover ll filters are delivered with a plugged clogging indicator connection M x. mm (connection P ). s clogging indicators either manometers or electrical pressure switches can be used. For the appropriate clogging indicators see catalog sheet 60.0. Remarks: The start of the red area respectively the switching pressure of the electrical pressure switch has always to be lower than the cracking pressure of the pressure relief valve (see Selection Chart, column 9). Clogging indicators are optional and always delivered detached from the filter. The filters listed in this chart are standard filters. If modifications are required, e.g. for horizontal assembly or with integrated suction valve integrated into the pressure relief valve (see section symbols, symbol no. ) to guarantee the emergency steering feature for vehicles with official road use, we kindly ask for your request. For de-aeration a bleed screw (for connection P ) with Part No. SV 0. is available. Page 7

Dimensions Ø M J J I H F E G C Versions with emergency-suction valve and protection strainer Ø L K Y* Ø D K Y* min. oil level O Connection M x. for clogging indicator Port sizes and mounting surface R Q P M0 U M0 V P N Z T Q M6 W X S Measurements in mm Type C D E F G H I J J K K L M N E 08 G¾,G G¾ 8 7. 7 0 F F 68 0. 0. 90 Type O P Q Q R S T U V W X Y* Z E 08 60 69 6.6 6 00 79 8 Measurements in inch Type SE SE C D E F G H I J mm J mm K K L M N E 08-6 -.89.89 0.7.8 0.8.0.0 F F 0.0 0. 0.8.. Type O P Q Q R S T U V W X Y* Z E 08.6.7 0. 0.6. 0.98.6.9. 0.8.0 8.8.7 * Oil outlet resp. emergency suction has to be under all operating cond. below min. oil level (given by Y) Page 8

Symbols Spare Parts 6 Pos. Designation Part No. Screw-on cap E 0.00 Flat gasket N0.08 O-ring N007.07 7 x mm.8 x 0. inch Replacement filter element see Chart / col. O-ring N007.08 8 x mm. x 0.6 inch 6 O-ring x mm 0.9 x 0.6 inch N007.0 The functions of the complete filters as well as the outstanding features of the filter elements assured by RGO-HYTOS can only be guaranteed if original RGO-HYTOS spare parts are used. Quality ssurance Quality management according to DIN EN ISO 900 To ensure constant quality in production and operation, RGO-HYTOS filter elements undergo strict controls and tests according to the following ISO standards: ISO 9 ISO 9 ISO 9 ISO 968 ISO 6889 ISO 8 Verification of collapse / burst pressure rating Verification of fabrication integrity (ubble Point Test) Verification of material compatibility with fluids Evaluation of pressure drop versus flow characteristics Multi-Pass-Test (evaluation of filter fineness and dirt-holding capacity) Determination of resistance to flow fatigue using high viscosity fluid Various quality controls during the production process guarantee the leakfree function and solidity of our filters. Illustrations may sometimes differ from the original. RGO-HYTOS is not responsible for any unintentional mistake in this specification sheet. Page 9