XMPA12B2142 pressure sensor XMP - 12 bar - G 1/4 female - 2 NC - without control type

Similar documents
Electromechanical pressure switches

Electromechanical pressure switches

References, characteristics. References (1) Complementary characteristics not shown under general characteristics (page 30395/3)

XML Electromechanical Pressure Switches

Limit switches OsiSense XC Special For material handling applications, type XC1 AC

Zelio Relays RSL Slim Interface Plug-In Relays

TeSys protection components

Data sheet Pressure switch type CS December 2001 DKACT.PD.P10.A B1119

Emergency Stop Devices/Rope Pull Switches

Available models Devices Color White sealing bellows Black sealing bellows NDT SW NDT GB NDT RT NDT GN NDT WS NDT BL NDT GR

Meta-MEC Manual Motor Starters

Pressure switch KP-E. Data sheet

Pressure switches for air and water CS

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073

EPIC Rectangular Connectors HBE Series

Prewired position switches FA series

Pressure controls for hydro carbons, zone II applications, Type KPE

Position switches FP series

Pressure switch, Differential pressure switch and Thermostat RT-E

Differential pressure controls, Type MP 54, 55 and 55A

Pressure Transmitters 36 F-27839

SPD310/SPD360 Air Differential

Differential Pressure Control Types MP 54, MP 55 and MP 55A

Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC

TURQUOISE SWITCHES ABJ (BJ) SWITCHES

CMC Series Moulded Case Circuit Breaker Cielo Electric

Valves, manually operated

Gas density monitor With integrated transmitter Model GDM-100-TI

2/2- and 3/2-way Rocker Solenoid Valve - bistable (impulse) version

Valves, manually operated

Air Sensor. SAC Ex. Manual ATEX. AQ Elteknik AB

Pressure control, differental pressure control and thermostat Type RT

Safety. Operating instructions Solenoid valve for gas VG 10/15 VG 65 DANGER. Contents WARNING CAUTION. Changes to edition 11.14

1 Overview. Pressure Measurement Transmitters for basic requirements. 1/16 Siemens FI SITRANS P220 for gauge pressure

EXH. Specifications. Descriptions. Min. working pressure MPa

Pressure switch and Thermostat Type KPS

Pressure Measurement Single-range transmitters for general applications

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/16 Siemens FI US Edition

Proportional pressure regulators VPPE

Types and approvals. Page 1/6. Data Sheet

E8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm)

Data sheet. Pressure switches and thermostats Type KPS 10/2003 DKACT.PD.P10.E B0782

Differential pressure switch MP 54, MP 55 and MP 55A

Air Sensor. FCS Ex. Manual. AQ Elteknik AB

Pressure switches and thermostats, type KPS

EPIC Rectangular Connector Inserts. HBE Series. Technical Data Number of Contacts:

Quick Reference Guide Power Series Switches

Pressure switch and Thermostat KPS

Datasheet PDCSY-PL-625. Technical Overview. Features. Product warranty and total quality commitment. Static Pressure Switch

Pressure switch and Thermostat CAS

P9000 DESCRIPTION. For parts requiring RoHS compliance, please contact factory. P February /6

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI

VMR VMR-OTN VMR 6 bar

CFSW. Hinges with built-in safety multiple switch

Solenoid valves VZWF, force pilot operated

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI US Edition

LMP 307. Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % / 0.

F series Foot Switches

4/2 way Pneumatic Solenoid Valve

2-port seat valves PN25 with externally threaded connections

High-performance submersible pressure transmitter For level measurement Model LH-10

P900. P900, Datenblatt Seite 1 DESCRIPTION

Tightness controls TC 1 3 and TC 4

Operating Instructions

Meta-MEC Manual Motor Starters

OSAT Series. Intrinsically Safe Infrared Temperature Sensor Operator's Guide

Pressure Measurement Single-range transmitters for general applications

Prewired position switches FA series

SITRANS P measuring instruments for pressure

RTD Temperature sensor TH11

Magnetic level switch type MR783 Instruction Manual

[Instruments for vacuum measurement, checking and adjustment] 3

Installation, operating and maintenance Instructions for Seemag bypass level indicator

MZX. Three-Port Seat Valves SPECIFICIATIONS AND GUIDE TO SELECTION

Slit Valve. XGT Series. Low particle generation. With end lock mechanism. Service life of two million cycles. XLA XL XL Q D- XSA XVD XGT CYV

Pressure independent control valve (PICV) FLOWMATIC

IP65 Air Differential Pressure Switch

Sanitary RTD Temperature sensor TH17. Measuring System Sanitary RTD assembly with connection head TH17 for food and dairy applications.

OPTIBAR P 1010 C Technical Datasheet

PRODUCT SPECIFICATION

Operating Instructions Rope Pull Switches RPS...

Diaphragm pressure switches, 42 V

EX-RECESSED CEILING LIGHT FITTINGS

Technical Datasheet. Rigid & Retractable Pendants. Rigid Pendant

DMK 458. Pressure Transmitter for Marine and Offshore. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.25 % FSO option: 0.

High-performance submersible pressure transmitter For level measurement Model LH-10

Pressure controls, differential pressure controls type RT

Electropneumatic Positioner Type 4763 Pneumatic Positioner Type 4765

Climatic Independent Level Sensor LAR

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

CFSW. Hinges with built-in safety multiple switch

Safety. Operating instructions. Pressure switches for gas DG..H, DG..N. Pressure switch for gas DG..I DANGER. Contents WARNING CAUTION

Double gas valves for biogases and recycling gases

References 6 k thermal overload relays, adjustable from 0.11 to 16 A

Technical Data. Dimensions

Technical Data. Dimensions

HYDRA-line. HYDRA-Gauges Ultra High Purity Pressure Gauge Model HG. Pressure Systems. Applications. Special features. Description

D. ACCESSORIES ADAPTER KITS IMPELLER & SEAL INSTALLATION TOOLS CARRYING HANDLES & LIFT CORDS GALVANIC PROTECTION KITS MUSHROOM STRAINER

Transcription:

Characteristics pressure sensor XMP - 12 bar - G 1/4 female - 2 NC - without control type Main Range of product Pressure sensor type Pressure sensor name Pressure sensor size OsiSense XM Electromechanical pressure sensor XMP 12 bar Fluid connection type G 1/4 (female) conforming to ISO 228 Controlled fluid Cable entry Contacts type and composition Product specific application - Pressure switch type of operation Electrical connection Electrical circuit type Scale type Local display Sale per indivisible quantity 1 Complementary Adjustable range of switching point on falling pressure Adjustment range high setting Possible differential minimum at low setting Possible differential minimum at high setting Possible differential maximum at high setting 28/03/2019 Air (0...70 C) Fresh water (0...70 C) Sea water (0...70 C) 2 entries incorporating Pg 13.5 plastic cable gland, cable outer diameter: 9...13 mm conforming to NF C 68-300 2 NC snap action Regulation between 2 thresholds Screw-clamp terminals, clamping capacity: minimum : 2 x 4 mm² Power circuit Adjustable differential Without 0.3...10.3 bar 1.3...12 bar 1 bar 1.7 bar 8.4 bar 1 Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications

Destruction pressure Type of decompression valve Control type Terminal block type Pressure actuator Materials in contact with fluid Enclosure material Operating position Operating rate 30 bar Without Without 4 terminals Diaphragm Canvas covered nitrile Chromated zinc alloy PA impregnated with fibreglass Any position 10 cyc/mn Repeat accuracy < 3.5 % [Ui] rated insulation voltage 500 V conforming to EN/IEC 60947-1 [Uimp] rated impulse withstand voltage 6 kv conforming to EN/IEC 60947-1 Resistance across terminals <= 25 MOhm conforming to IEC 60255-7 category 3 <= 25 MOhm conforming to NF C 93-050 method A Electrical durability Mechanical durability Setting Terminals description ISO n 1 Depth Height Width 1000000 cycles (1.5 kw, operating rate: 10 cyc/mn, load factor: 0.4, 400 V AC 3 phases) 500000 cycles (3 kw, operating rate: 10 cyc/mn, load factor: 0.4, 400 V AC 3 phases) 600000 cycles (1.5 kw, operating rate: 10 cyc/mn, load factor: 0.4, 230 V AC 3 phases) 700000 cycles (2.2 kw, operating rate: 10 cyc/mn, load factor: 0.4, 400 V AC 3 phases) 1000000 cycles Knurled knob and nut (1-2)NC (3-4)NC 98 mm 106 mm 57 mm Environment Product certifications Standards EAC CE EN/IEC 60947-4-1 Ambient air temperature for operation -25...70 C Ambient air temperature for storage -40...70 C Vibration resistance 3 gn (f = 10...500 Hz) conforming to IEC 60068-2-6 Shock resistance 50 gn conforming to IEC 60068-2-27 Electrical shock protection class Class I conforming to IEC 60536 IP degree of protection IP54 conforming to EN/IEC 60529 Offer Sustainability Sustainable offer status RoHS (date code: YYWW) REACh Product end of life instructions Green Premium product Compliant - since 0627 - Schneider Electric declaration of conformity Schneider Electric declaration of conformity Reference not containing SVHC above the threshold Reference not containing SVHC above the threshold Need no specific recycling operations Contractual warranty Warranty period 18 months 2

Dimensions Drawings Dimensions Without Decompression Valve ØA = G 1/4 (1) 2 tapped entries for Pg 13.5 3

Mounting and Clearance Minimum Mounting Clearance ØA = G1/4 (1) Minimum clearance zone for screwing-on pressure switch at point A 4

Connections and Schema Wiring Diagram Terminal Connections 5

Performance Curves Curves Operating Curves (y) Rising pressure (x) Falling pressure 1 : Maximum differential 2 : Minimum differential (y) Pressure (x) Time (1) Adjustable value PH : High point PB : Below point 6