Series SFD. Clean Air Filter. Variations. Made to Order. Type. Cartridge (replaceable element) Disposable (non-replaceable element) Up to 100

Similar documents
Clean Air Filter Built-in Hollow Fibre Element

Clean Gas Filter. SF Series. Cartridge Type/Disposable Type IDFA IDFB IDH ID IDG IDK AMG AFF AM AMD AMH AME AMF ZFC SF SFD LLB AD GD SFC10

Pilot Check Valve: Metal Body Type

Compressed Air Cleaning Filter Series

Related Products: Auto Drain Valve. Model/Specifications. Model

Regulator for 2 MPa ARX 20. How to Order. Bracket. Pressure gauge. Port size 1/8 1/4. Panel nut

Series AS-FPQ/AS-FPG. Speed Controller with One-touch Fitting for Clean Room. Speed controllers for clean room use

Suitable for Semi-Conductor, Measuring Instrument, Printing and Medical Industries

Clean Speed Controller with One-touch Fitting

Direct Operated Precision Regulator Modular Style. Standard Specifications

Port size. Model Screw-in ZFA10 1/8 ZFA20 1/4 ZFB10 ZFB20 ZFB30 ZFB40 ZFC5 ZFC7

Process Pump. Self-priming makes priming unnecessary. Air operated type. Air supply port. 5 port solenoid valves. Application Example

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

Hand Valve Series. Push-In Fitting Type Shut-off Valve (Residual Pressure Release Valve) Control Open/Close for Air Supply.

Series IRV1000/2000/3000

Compressed Air Cleaning Filter Series

Booster Regulator/Air Tank

New Product. Air Consumption 70% Down. Precision Regulator Air Saving Type. RPE Series PRECISION REGULATOR RPE SERIES CC-1072A

AMG. Model Note) Rated flow (l/min (ANR)) Port size Mass (kg) 1 8, , 3 8. Specifications Fluid. Element life

Clean Air Filter Built-in Hollow Fiber Element

kpa or less 5.0. Compressed Air Preparation Filter. AFF/AM/AMD Series CAT.ES30-17B. 1 μm (Current model: 3 μm) 20% 60% 52% 160 mm.

Maximum 0.85 MPa pressure setting Long-life, high flow perfect for balancer applications

F.R.L. Units Precautions 1 Be sure to read this before handling.

Power Valve: Precision Regulator. High precision, large capacity relief regulator

Series AMJ. Drain Separator for Vacuum

Coiling Tube with Twist-Proof Fitting

Cautions : 1. Clogging of the element raises resistance to exhaust, thus lowering the

PVC Quick Drain Valve

Recommended applicable tubing. Specifications. Operating vacuum pressure. 20 C to 80 C Threads. Principal parts material

Process Pump. Series PAF3000/Series PAF5000

Change Valve. Push-In Fitting Type Three-way Changeover Valve. Changeover Air Direction by 90. Lightweight and Compact Design.

30% (SMC comparison) Silencer. New. New. The M5 silencer is now added! The resin silencer is now a more compact size! Series AN.

Series ZFC. Air Suction Filter In-line Type with One-touch Fittings

(1) Type (2) Thread size (T) (3) Wrench size specification : inch spec. (NPT, UNF) : mm spec. (M, R)

Compact Regulator. ARX20 Series. 2.0 MPa compatible, piston type compact regulator ARJ

VACUUM REGULATORS CONTENTS

Regulator. Accessory. Description. Symbol. Nil. With bracket. B With round. Port size. (Without limit indicator) With set nut (For panel mount)

COMMON PRECAUTIONS Data Sheet - Be Sure To Read Before Handling Page 1 of 6

Precision Regulator. Series Model Regulating pressure range Port size Page

Pressure Relief 3 Port Valve New. Sonic Conductance 45% With the indicator window Step1. With locking holes

Push-In Fitting Type with Stop Valve

F.R.L. Units Precautions 1 Be sure to read this before handling products.

Cautions : 1. Be careful when you release the Stop Fitting with some internal pressure

3/8" Dr. Air Butterfly Impact Wrench

PRODUCT NAME. Main Line Filter. MODEL / Series / Product Number

Filter regulator. Accessory. Description. Symbol. B With bracket With round. Port size. (Without limit indicator) Body size.

Series VBA1110 to 4200

Cautions : 1. The gauge orientation on the GPU and GPM types can be changed by using

Clean Regulator/Fluororesin Type

Push-In Fitting Type Silencer

Vacuum Saving Valve Series ZP2V How to Order ZP2V A5 03 Connection thread symbol for the pad Male thread connection Symbol Thread Applicable fixed ori

Operation Manual Air Saver Unit ASV5000 Series

Auto Feed Lube, Auto Feed Tank ALF400 to 900, ALT-5/-9

ALF400 to 900, ALT-5/-9

Standard Specifications. Fluid Proof pressure Maximum operating pressure. Regulating pressure range

Specifications. Construction. 2 port valve/series VHK2 3 port valve/series VHK3. Component Parts. Standard style. Flame resistant style

(1) Type (2) Cylinder dia. (3) Gripper action : Single-acting closing gripper (normally open) (4) Holder type

Push-In Fitting Type Pressure Gauge

Process Pump Automatically Operated Type (Internal Switching Type) Air Operated Type (External Switching Type) How to Order

The plastic bowl guard does not corrode. The draining method is selectable between the push type and the auto drain type.

Process Pump. PAF3000 Series/PAF5000 Series

Precision Regulator. IR1000/2000/3000 Series ARJ ARX AMR ARM ARP IR -A IR IRV VEX SRH SRP SRF ITV IC ITVH ITVX PVQ VY1 AP100.

Insert Ring. Protection Ring from Tube Deformation. Protect tubes from deformation. Ultra soft tube is connectable to Fitting.

No.IL02-OM00011-A PRODUCT NAME LOCK UP VALVE. MODEL/ Series IL201 IL211

IR1000-A IR1010-A IR1020-A

Air preparation filter

Compact Manometer. Pressure measurements can easily be taken any time, anywhere. POWER LIGHT

Speed Controller Constant Flow

Self-priming makes priming unnecessary Exhausts the air inside the suction pipe to suck up liquid. Air operated type.

(1) Type. (2) Tube dia. (ød) : ø8mm (ø5/16in.) (3) Thread size (T) (4) Specification. Fluid medium. Air, water * 1, * 2, * 3 Max. operating pressure

Tube for Clean Environment Polyurethane Tube Clean-Room Package

Mounting and Operating Instructions EB EN. Type Supply Pressure Regulator. with increased air capacity

Pressure Gauge Series

How to Order. Body size. Pressure: 2 MPa. Pressure increase ratio 0 Twice. Symbol. Thread type. Body size

EXH. Specifications. Descriptions. Min. working pressure MPa

Tube Cutter with Measuring tape built-in

Low torque Metal seal type Rotary joint

Air operated valve. VGA342R Series

Series 10-IRV10/20. Vacuum Regulator C08 IRV C08 IRV 20 A. How to Order. Standard connections. Single sided connections. Accessory w Nil G ZN ZP ZA ZB

Doc. No.SYJ300-OMO0002-A. Air Operated Valve PRODUCT NAME. SYJA300 / SYJ3000 Series MODEL/ Series

Ejector for Conveying particles, powder and fibers Vacuum GeneratorVRL

Ball Valve Series. Push-In Fitting Type Shut-off Valve. Control Open/Close Air Supply. Ensure Effective Area for Variety of Tube Dia.

Moisture Control Tube

Static dissipative Resin (Surface Resistivity : 10 4 ~10 7 Ω).

(2) Effective sectional area (no code for mini type) (3) Intake-side shape (no code for mini type) : Quick-fitting joint type : Taper pipe thread type

Process Pump Automatically Operated Type (Internal Switching Type) Air Operated Type (External Switching Type) How to Order. Option. Symbol.

(1) Name of tube (2) Tube dia. (O.D./I.D.) (3) Tube length. (4) Tube color. Model UD0425. UD1290 O.D. I.D. (mm) UD1075 UD0860 UD

Anti-spatter Tube. Spatter-Proof Tube for Pneumatic Piping. Polyamide type Tube Coated with Flame-Retardant Resin(Equivalent to V-0 )

KTM OM-2 SPLIT BODY FLOATING BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

Filter-Regulator-Lubricator

/ Air Line Kit AL - M1202. / OPERATION MANUAL P1 - P9 / English P11 - P19 OM-K0651

Air Saving Valve. Pressure Valve Flow Valve

Model GP PRESSURE REDUCING VALVE Installation & Operation Manual

SeriesTRBU. Flame Resistant (Equivalent to UL-94 Standard V-0) FR Double Layer Polyurethane Tubing

Industrial Filter. FGD series

THE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401

Specifications. Construction. 2 port valve/series VHK2 3 port valve/series VHK3. Component Parts. Standard style. Standard style

ACCUMULATOR OPERATING & MAINTENANCE INSTRUCTIONS

(1) Union Filter for positive and negative pressure (2) Filter size. (3) Tube dia. (4) Holder option : without Holder : with Holder

reduces flow setting time and setting errors!

Transcription:

Clean Air Filter Variations SFD SFD SFD SFD Made to Order Type Disposable (non-replaceable element) Cartridge (replaceable element) Flow rate L/min (ANR) (at inlet pressure.7 MPa) Up to 6 Up to 8 Up to Up to Up to Up to 5 Up to Port size One-touch fitting Female thread ø ø6 Rc/, G/ NPT/ ø ø Rc/, G/ NPT/ Rc /, G /, NPT / Case material Resin Resin Aluminum Stainless steel Fluid Air (Nitrogen) Nominal filtration rating. µm (filtration efficiency: 99.99%) Note) Initial pressure drop Maximum operating pressure (at C) Operating temperature Page. MPa (at inlet pressure.7 MPa, maximum flow). MPa (in case of nitrogen:.99 MPa) 5 to 5 C Page Page 5 Note) The clean air filter is designed for the filtration of solid objects. It is not suitable for the separation of water and oil. 9

Model Selection Select the model by using the following procedures involving the inlet pressure and the maximum flow rate. [Example] Inlet pressure:.6 MPa Maximum flow rate: L/min (ANR). Obtain the intersection A for the inlet pressure and the maximum flow rate by using the maximum flow rate chart.. If the obtained intersection A is above the maximum flow rate line, the SFD-C, -, -C, or -C8 are selected. Directional Control Valves Maximum Flow Rate Flow rate (L/min(ANR)) SFD-C, - SFD-C SFD-C8 SFD-C8, - A SFD- SFD-6.5 Pressure (MPa) Flow Control Air Preparation Pressure Control Fittings & Tubing Modular F. R. Air Grippers Rotary Actuators Air Cylinders Pressure Switches/ Pressure Sensors

Clean Air Filter RoHS How to Order Clean air filter SFD C8 Symbol Size Max. flow rate L/min (ANR) 5 L/min (ANR) Case material Symbol Material Resin Aluminum Stainless steel Symbol and are made to order. For details, refer to page 5. Option Symbol Nil B Option None (SFD only) The brackets are provided with the SFD series as a standard product. (Nil) Port size Symbol Connection size Note C C6 C8 C C N F ø ø6 ø ø Clean One-touch fittings (Series KP) Rc / NPT / G / SFD only SFD/ SFD only Female thread SFD/ Relationship between Operating Temperature and Max. Operating Pressure Specifications Different diameters for IN and OUT ports are Made to Order. For details, refer to page 6. Max. operating pressure (MPa)...8.6.. 5 Operating temperature ( C) Model Port size Fluid Air flow capacity Nominal filtration rating Note ) Operating pressure range Note ) Operating temperature Initial pressure drop proof differential pressure Note ) Proof pressure service life SFD One-touch fittings ø, ø6, Rc, NPT, G / Air (Nitrogen) Up to L/min (ANR) SFD One-touch fittings, ø, ø Rc, NPT, G / Air (Nitrogen) Up to 5 L/min (ANR). µm (99.99%) kpa to. MPa (in case of nitrogen:.99 MPa) 5 to 5 C. MPa (at inlet pressure.7 MPa, maximum flow).5 MPa.5 MPa year, or when the pressure drop reaches. MPa. Note ) Measured under SMC s specified conditions. Note ) The maximum operating pressure varies depending on temperature. Refer to the graph that shows the relationship between operating temperature and maximum operating pressure on the left. Note ) This means that the element does not break at.5 MPa. See Specific Product Precautions. Model Port size Rated flow (L/min (ANR)) Note ) Weight ø (One-touch fittings) 6 5 g SFD ø6 (One-touch fittings) 8 5 g (One-touch fittings) 5 g Rc, NPT, G / 5 g SFD Note ) Rc, NPT, G / 6 g SFD Note ) Rc, NPT, G / 5 g (One-touch fittings) 9 g SFD ø (One-touch fittings) 9 g ø (One-touch fittings) 5 9 g Rc, NPT, G / 5 6 g Note ) The maximum flow rate when the inlet pressure is.7 MPa. Note ) SFD and SFD are produced upon receipt of order.

Clean Air Filter Flow Rate Characteristics SFD-C.. MPa. MPa.5 MPa.7 MPa SFD-C8.. MPa. MPa.5 MPa.7 MPa Directional Control Valves...9 MPa. 6 SFD-C6.. MPa. MPa.5 MPa.7 MPa...9 MPa. 6 8 SFD-C8, -, -N, -F.. MPa. MPa.5 MPa.7 MPa...9 MPa. 6 8...9 MPa.. SFD-C.. MPa. MPa.5 MPa.7 MPa...9 MPa. 5 SFD-C, -, -N, -F.. MPa. MPa.5 MPa.7 MPa...9 MPa. 5 6 Fittings & Tubing Modular F. R. Air Grippers Rotary Actuators Air Cylinders Air Preparation Pressure Control Flow Control Pressure Switches/ Pressure Sensors

Clean Air Filter Construction SFD-C t r q w e 5 O-ring Cassette PC, Polyolefin, PU, PET, ABS PBT PBT PP, EPDM, Stainless steel Material set SFD-BR No. Description Note With countersunk head screws (M) SFD- r q w O-ring PC, Polyolefin, PU, PET, ABS PBT PBT Material set SFD-BR No. Description Note With countersunk head screws (M) e SFD-C o! r y q i w e PC, Polyolefin, PU Aluminum alloy Fitting body PBT Cassette PP, EPDM, Stainless steel 5 6 O-ring A 7 O-ring B 8 Rod cover 9 Tie-rod Cap nut t u! Plain washer set SFD-EL With O-rings SFD-! i t q u w e Fitting body PC, Polyolefin, PU Aluminum alloy 5 O-ring A 6 O-ring B 7 Rod cover 8 Tie-rod 9 Cap nut Plain washer r y o set SFD-EL With O-rings

Clean Air Filter Dimensions SFD-C SFD- SFD-C SFD- SMC 5 7 B SMC 5 7 SMC 96.5.5 B ø ø 7 7.7 6. 7 Applicable tubing O.D. øa 7.7 6. 6 Applicable tubing O.D. øa mounting dimensions.8 5.8 Hole shape for bracket mounting ø.5 9.5 SFD-C Dimensions Model A B SFD- C C6 C8 6 8 8 8 8 SFD-C Dimensions Model A B SFD- C8 C C 8 5 6 6 mounting dimensions.5 Use a countersunk head screw (M) for bracket mounting. x.5 x 7 8 Directional Control Valves Fittings & Tubing Modular F. R. Air Grippers Rotary Actuators Air Cylinders Air Preparation Pressure Control SMC Flow Control 96.5 9.5 6 Pressure Switches/ Pressure Sensors

Made to Order Contact SMC for detailed specifications, delivery and prices. Metal Case Clean air filter Symbol q SFD Size Max. flow rate L/min (ANR) The SFD is not applicable. Construction SFD- Case material Symbol Material Aluminum Stainless steel e r Port size Symbol N F w Connection size Rc / NPT / G / The metal case is not available with a clean One-touch fitting. The bracket is provided as a standard product. SFD- Metal case suitable for an atmosphere exposed to organic solvents and chemicals Specifications The specifications are the same as the standard product. Refer to Specifications on page. Flow Rate Characteristics The flow rate characteristics are the same as the SFD-. Refer to Flow Rate Characteristics on page. q e r t w No. Description Material Note Case O-ring Aluminum alloy Aluminum alloy PC, Polyolefin, PU, PET, ABS FKM No. Description Part no. Note set SFD-EL SFD-BR With O-ring Material: Stainless steel No. Description Material Note 5 Case Hex. socket head set screw O-ring PC, Polyolefin, PU, PET, ABS FKM No. Description Part no. Note set SFD-EL SFD-BR With O-ring Material: Stainless steel Dimensions SFD- SFD- 5 66 9 5 9 66 ø ø 5 5 5 x ø.5 x ø.5

Made to Order Contact SMC for detailed specifications, delivery and prices. Different Diameters for IN and OUT Ports One-touch fitting dimensions (A, B) ø ø6 Symbol IN port size Clean air filter Port size q.5.5 5 Size Max. flow rate L/min (ANR) 5 L/min (ANR) C C6 C8 C C N F SFD C C6 Case material Symbol Material Resin IN side connection symbol IN side Connection size connection symbol ø ø6 ø ø Clean One-touch fittings (Series KP) Rc / NPT / G / SFD Different Diameter Combinations OUT port size C C6 C8 N F C C6 C8 N F The symbol stands for unavailable combination. Dimensions SFD different diameters SMC Basic dimension 7 Fitting dimension A OUT side connection symbol OUT side Connection size connection symbol Port size w C C6 C8 C C N F IN/OUT combination is the below table. Fitting dimension B IN port size ø ø6 ø ø Option Symbol Option Nil None B (SFD only) The brackets are provided with the SFD series as a standard product. (Nil) Clean One-touch fittings (Series KP) Rc / NPT / G / SFD Different Diameter Combinations OUT port size C8 C C N F C8 C C N F The symbol stands for unavailable combination. One-touch fitting dimensions (A, B) ø ø Port size q 5.5 5.5 5.5 Specifications The specifications are the same as the standard models. Refer to Specifications on page. Flow Rate Characteristics When the IN and OUT ports have different diameters, the flow rate characteristics will be those of the port with the smaller diameter. Refer to Flow Rate Characteristics for the smaller diameter from the chart of standard product on page. Construction SFD different diameters The construction and materials are the same as the standard product. Refer to Construction on page. Fitting dimension A Basic dimension.5 Fitting dimension B Port size w Directional Control Valves Fittings & Tubing Modular F. R. Air Grippers Rotary Actuators Air Cylinders Air Preparation Pressure Control Flow Control Model Port size q C (C6) C ( ) C6 (C8) C6 ( ) C8 ( ) Port size w C6 (C) (C) C8 (C6) (C6) (C8) Total length 8 (A + 7 + B) 76.5 (7 + A) 8.5 (A + 7 + B) 76.5 (7 + A) 77 (7 + A) Model SFD- SFD- Port size q C8 (C) C8 ( ) C (C) C ( ) C ( ) Port size w C (C8) (C8) C (C) (C) (C) Total length 5.5 (A +.5 + B) (.5 + A) 5.5 (A +.5 + B) (.5 + A) (.5 + A) 6 Pressure Switches/ Pressure Sensors

Specific Product Precautions Be sure to read this before handling. Refer to page 8 for Safety Instructions and pages 6 to 66 for Air Preparation Precautions. Warning Selection. Thoroughly and carefully confirm the purpose of use, required specifications and operating conditions (fluid, pressure, flow rate, nominal filtration rating and environment) then select a model within the specifications.. The product is not certified under the High Pressure Gas Safety law, so for nitrogen, its maximum operating pressure will be.99 MPa (gauge pressure).. Contact SMC beforehand if the product will be used in an application such as a caisson shield, breathing, food and/or medical treatment that affects the human body directly or indirectly.. If the compressed air includes ozone, do not use it since it may damage the product or cause malfunction. When it includes ozone, use a clean gas filter (SFA/B/C). Warning Mounting. Operation manual Mount the product after reading and understanding the operation manual. Keep it in a location where it can easily be found.. Flushing Flush the piping line when the filter is used for the first time or has been replaced. In the event of connecting such as piping, flush (air blow) when using this product for the first time or replacing its elements in order to reduce the affect of the dust generated from the connection, etc. Flushing the line is also required to eliminate contamination resulting from the piping line installation. Therefore, be sure to flush the line before actually running the system. Fix all mounting parts for use.. Use fittings with resin threads for the connection of fittings to the IN and OUT ports. Using fittings with metal threads could damage the IN and OUT ports.. Connect tubing to the IN and OUT One-touch fittings in accordance with the precautions for One-touch fittings. Caution. Connect the piping in accordance with the flow direction marked on the case. If connected in reverse, the element could break.. The mounting orientation does not affect the performance, but if excessive force is applied to the SFD series, the body may become disconnected from the bracket. Therefore, take particular care about the mounting orientation. 7 Warning Caution on Installation. The material of the element is polycarbonate. The material is resistant to wiping with alcohol, but is not suitable for atmospheres or places with organic solvents, chemicals, cutting oils, synthetic oils, ester base compressor oils, alkalis or thread locking agents. Caution. If the pressure difference (pressure drop) between the inlet and the outlet exceeds. MPa, it can cause damage to the product.. Do not install the product in a place where it can be affected by a pulsation (including surge pressure) of over. MPa.. Use caution regarding the particles that may be emitted from the outlet side of a pneumatic equipment. Installation of a pneumatic equipment on the outlet side can deteriorate the cleanliness because a particle will be generated from the equipment. The mounting position of the pneumatic equipment needs to be considered.. Set the air flow capacity with an initial pressure drop of. MPa or less. If the initial pressure drop is set to be high, its service life will be shorten due to clogging. 5. Determine the product by the maximum consumption flow rate. When using compressed air for an air blow application, calculate the maximum volume of air that will be consumed before selecting the SFD series product size. 6. Generally, the following pollutant particles are contained in compressed air. [Pollutant particle substances contained in the compressed air] Moisture (drainage) Dusts and particles which are in the surrounding air Deteriorated oil which is discharged from the compressor Solid foreign matter such as rust and/or oil in the piping ) The SFD series is not compatible with compressed air which contains fluids such as water and/or oil. ) Install a dryer (IDF, IDG, ID series), mist separator (AM series), micro mist separator (AMD series), super mist separator (AME series), or odor removal filter (AMF series), etc., for the source of the air for the SFD series. 7. Using with a flow rate much higher than its specifications could lead to exceeding the differential pressure the product can resist. Use the product within its specifications. Also, take care about the replacement period of the product, taking into consideration that the differential pressure of the filter will increase over time.

Specific Product Precautions Be sure to read this before handling. Refer to page 8 for Safety Instructions and pages 6 to 66 for Air Preparation Precautions. Caution Piping. Unpacking the sealed package Since the filter is sealed in an antistatic double bag, the inner package should be unpacked in a clean atmosphere (such as a clean room).. Apply a wrench to chamfered flats or hexagon portion on the IN side or the OUT side to prevent the housing from rotating.. Always tighten threads with the proper tightening torque. When attaching fittings to the product, tighten with the proper tightening torque shown below. Material Resin Metal. Check the arrow mark on the case which shows the flow direction to connect the IN and OUT ports correctly. If connected in reverse, the element could break. Warning Tightening torque (N m) to to Maintenance. Follow the maintenance procedures in the operation manual. If handled incorrectly equipment or device can be damaged or cause a malfunction.. When removing the product, exhaust the air and ensure the air is released to atmosphere before removing it.. When the element comes to the end of its life, immediately replace it with a new filter or replacement element (cartridge type). Service life of element The service life of the element ends when either of the following two conditions occurs. ) After year of usage has elapsed. ) When the pressure drop reaches. MPa even though the operating period has been less than year. Warning Operating Environment. Do not operate under the conditions listed below due to a risk of malfunction. In locations having corrosive gases, organic solvents, and chemical solutions, or in locations in which these elements are likely to adhere to the equipment. In locations in which salt water, water, or water vapor could come in contact with the equipment. In locations that are exposed to direct sunlight. (Shield the equipment from sunlight to prevent its resin material from ultraviolet ray degradation or overheating.) In locations that have a heat source and poor ventilation. (Shield the equipment from heat sources to protect it from softening degradation due to radiated heat.) In locations that are exposed to shocks and vibrations. In locations with high humidity or a large amounts of dust.. When the product is used for blowing, use caution to prevent the work from being damaged by entrained air from the surrounding area. When the compressed air is used for air blow, the exhausted air from the blow nozzle may have taken in airborne foreign matter (such as solid particle, fluid particle) from the surround air. The foreign matter will be sprayed on the work, and the airborne foreign matter may adhere to it. Therefore, use caution for the surrounding environment. Caution Other Tubing Brands. When tubing of brands other than SMC s are used, verify that the tubing O.D. satisfies the following accuracy; ) Polyolefin tubing: Within ±. mm ) Polyurethane tubing: Within +.5 mm, within. mm ) Nylon tubing: Within ±. mm ) Soft nylon tubing: Within ±. mm Do not use tubing which does not meet these outside diameter tolerances. It may not be possible to connect them, or they may cause other trouble, such as air leakage or the tubing coming out after connection. The recommended tubing for the clean fitting is polyolefin tubing. Other tubing can satisfy the performance in terms of leakage, tensile strength, etc., but impair the cleanliness. Note this point for use. Flow Control Directional Control Valves Air Preparation Pressure Control Fittings & Tubing Modular F. R. Air Grippers Rotary Actuators Air Cylinders 8 Pressure Switches/ Pressure Sensors