E 212 E 222 Tank top mounting Connection up to G1¼ / -20 SAE Nominal flow rate up to 220 l/min / 58.1 gpm

Similar documents
E 094 E 103 E 143 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 135 l/min / 35.7 gpm

E 212 E 222 Tank top mounting Connection up to G1¼ Nominal flow rate up to 220 l/min

E 328 E 498 Tank top mounting Connection up to G1½ / -24 SAE and SAE 2 Nominal flow rate up to 600 l/min / gpm

E 441 E 451 E 461 E 641 E 700 Tank mounting Nominal flow rate up to 800 l/min

E 084 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 80 l/min / 21.1 gpm

E 328 E 498 Tank top mounting Connection up to G1½ and SAE 2 Nominal flow rate up to 600 l/min

D 042 D 062 In-line mounting Operating pressure up to 100 bar Nominal flow rate up to 90 l/min

E 158 E 198 E 248. Tank top mounting Connection up to G11 / 4 Nominal flow rate up to 250 l/min e d

MPS/MST SPIN - ON FILTER SUCTION - RETURN SERIES. Maximum working pressure 12 bar. Flow rates to 300 l/min

Change-Over Pressure Filter DFDK

2-way flow control valve Model 2FRM 6

Desiccant Air Breathers DBE. Section 3: TNK SCHROEDER INDUSTRIES ACCESSORIES 21

FIK In-Tank Filters FIK. Max Flow: 170 gpm (643 lpm) Working Pressures to: Rated Static Burst to: Flow Range to:

Pressure reducing valve, pilot operated, Model 3DR

D e s c r i p t i o n

Fixed Displacement Motor A4FM

Displacement 12, , Maximum flow rate (at 1450 rpm) bar.

Check Valves. Pilot Operated Check Valves. Vickers. 4CG-10, 20 Series 4CS-03, 20 Series 4CT-06/10, 20 Series. Basic Characteristics.

Compressed Air Conditioning Catalog Chapter I

Flow rates to 200 l/min

Flow Control Valves. 1 Description. 2 Symbols. Series MTKA, MTQA, MTCA 2.1 MTKA MTQA flow control valve. 1.1 MTKA flow control valve

Pressure reducing valve, pilot operated

VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10

Pressure reducing valve, direct operated

Pressure reducing valve, direct operated

Check valve hydraulically pilot operated

Auxiliary valve QDS6 Sequence valve, 3-way. Catalogue (GB) (US) October 1998

Fixed Displacement Pump KFA for commercial vehicles in open circuits

Directional Controls

PLD 03 T A CASAPPA S.p.A.

Fixed Displacement Plug-In Motor A2FE

4/3 Directional valve elements L8_P5 with proportional (ED-IP) control and with or without LS connections L8_P5 (ED-IP)

Pressure relief valve, direct operated

SPM. Pressure Filters MEDIUM PRESSURE INLINE FILTER

Function. Valve Size. Pilot Oil. p min. Bold: Designates Tier I products and options.

Electrically Operated Pressure-Relief Cartridge, Size 10

LMP 110 Maximum pressure 80 bar F l o w r a t e s t o l / m i n

Double Pilot Operated Cartridge Check Valve, Size 8

Spin-On Filters SSF 24,25

Pressure relief valve, direct operated

Air preparation units

BUTTERFLY VALVES. Toll Free (877) - ICFLUID -2-

Pressure-Relief Cartridge Valve, Size 4

Leak-Free Load-Control Valve SAE ½ psi flange

Variable Displacement Double Pump A20VO. Series 1, for open circuits Axial piston - swashplate design, Back to back - design

Cooler-Bypass Thermostat Valve, Size 16

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R

LMP Filter element in according to DIN Style B. Style S. Maximum pressure 30 bar F l o w r a t e s t o l / m i n D.I. D.I.

WK /2 WAY CARTRIDGE VALVE TYPE URZS 32 COVER FOR CARTRIDGE VALVE TYPE ULZS 32. Size 32 up to 42 MPa 700 dm 3 /min DESCRIPTION OF OPERATION

Dual displacement motor A10VM Plug-in dual displacement motor A10VE for open and closed circuit applications

3-Way Safety Block DSV

Size 10 (D05) p max 320 bar (4600 PSI) Technical Features. Technical Data. Port dimensions ZB10A(B) SMT_0019 ZB K -

Pilot Check Valve: Metal Body Type

EXH. Specifications. Descriptions. Min. working pressure MPa

ALF400 to 900, ALT-5/-9

Proportional Pressure-Relief Cartridge Valve, Size 2...4

3-Way Pressure-Reducing Cartridge, Size 2 4

Pressure relief valve, direct operated Type DBD

HIGH PRESSURE FILTERS DFDK Series Inline Duplex Filters 4568 psi up to 90 gpm

Installation and commissioning instructions 255 series and 256 series

ALF400 to 900, ALT-5/-9

L6090 (LC04M-CBL) - L6095 (LC04M-CBD)

ALF400 to 900, ALT-5/-9

Prop. 3-Way Pressure-Reducing Cart., Size 5 / SAE 08

Fixed Displacement Motor A4FM

Technical Data Sheet TI-F50 Locking Units series KFH

Pressure relief valve, direct operated. Type DBD. Features. Contents. RE Edition: Replaces:

Inverse Prop. Pressure-Relief Cart., Size 2 4

Auto Feed Lube, Auto Feed Tank ALF400 to 900, ALT-5/-9

Technical data sheet. Type overview. Technical data. Safety notes. T5-R2.. Open-close en v Subject to changes 1 / 3

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R

BW0500AO. ByWire Elements BW0500AO Element 4/3 with side ports IBW0500 Interface

List of Contents vma. Compressed Air Conditioning 2. System description 2. Individual Units Pre-Filters 3. Combinations 6

Full Range Pressure Compensating Variable Flow Control

Flow control valves Series RFU - RFO 2/

DNS. Monoblock directional control valves DNS - Directional control valve

MECHANICALLY OPERATED DIRECTIONAL VALVES Rotary Type : DRT/DRG-02 Cam Operated : DCT/DCG-01, 03 Threaded Connection/Sub-plate Mounting

VICKERS. SystemStak Valves. ISO ; NFPA-D03; 315 bar (4500 psi); 60 L/min (15.7 USgpm) GB 2027B

Two-stage valve type NE

Compressed Air Cleaning Filter Series

005 Series Modular Valves

Logic Elements Screw-in Cartridge Valves Pressures to 290 bar (4200 psi) Flows to 303 l/min (80 USgpm)

Two-port valves, male threaded, PN25

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

Inverse Proportional Pressure-Relief Cartridge, Size 10

180 Series Rotary Shear Directional Control Valve

Operating Instructions VETTER Pipe and Test Sealing Bags

lternative odels 3.87 (98) anual Drain 2.67 (68) 3.72 (94) utomatic Drain 2.13 (54) 1.12 (28) P1H, PTH Filter/Regulator-Lubricator Combination Units 0

Leak free Pipe Rupture Valve for Excavators

D62 - D63 Directional Control Valve l/min

STAD-C. Balancing valves DN 15-50

Directional Control Valves Technical Information Model 1500

Type 4708 Supply Pressure Regulator

Self-priming makes priming unnecessary Exhausts the air inside the suction pipe to suck up liquid. Air operated type.

Pressure regulator for water

Pressure-controlled shut-off valve type CNE

List of Contents VMA. System description 2. Individual Units Pre-Filters 3. Combinations 6. Accessories and Main spare parts 6

Pressure Independent Control Series

STAD. Balancing valves DN 15-50

Industrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US

Transcription:

Return Filters E E Tank top mounting Connection up to G¼ / - SE up to l/min / 8. gpm Description pplication In the return line circuits of hydraulic systems. erformance features rotection against wear: y means of filter elements that even in full-flow filtration meet the highest demands regarding cleanliness classes. rotection against malfunction: y means of full-flow filtration in the system return, the pumps above all are protected from dirt particles remaining in the system after assembly, repairs, or which are generated by wear or enter the system from outside. Special features Return Filter E y-pass valve: The location close to the inlet port prevents dirt particles retained by the filter element from entering into the clean oil side. Removable bowl: In case of maintenance the filter bowl is removed together with the filter element - therefore dirt particles are not flushed back into the tank. Filling filter / y-pass protection strainer: The filling filter is integrated in the filter element and prevents coarse particles from entering during filling or re-filling due to maintenance or repair reasons. Filling can be carried out at the filter. Therefore the cover must be removed. In operation, the filling filter functions as a by-pass protection strainer and prevents dirt from entering into the tank when the by-pass valve is open. ort for ventilating filter: The ventilating filter thread connection M x allows assembly of a ventilating filter, which assumes ventilation of the tank. The ventilating filter has to be ordered separately. Filter elements Flow direction from outside to center. The star-shaped pleating of the filter material results in: large filter surfaces low pressure drop high dirt-holding capacities long service life Filter maintenance y using a clogging indicator the correct moment for maintenance is stated and guarantees the optimum utilization of the filter life. age 7

Materials Screw-on cap: Filter head: Filter bowl: Seals: Filter media: Filling filter: olyester, GF-reinforced luminum alloy olyamide, CF-reinforced, electrically conducting NR (FM on request) EXOR MX - inorganic multi-layer microfiber web aper - cellulose web, impregnated with resin olyamide, reinforced; olyester web ccessories Electrical and / or optical clogging indicators are available on request. Dimensions and technical data see catalog sheet.. Ventilating filters with connection thread M x have to be ordered separately. Dimensions and technical data see catalogue sheet. and.. Extension pipes or diffusors on the bowl outlet are available on request. Extension pipe correct extension pipe length ensures oil outlet below minimum oil level and prevents foaming. Characteristics Return filter: Up to l/min / 8. gpm (see Selection Chart, column ). The nominal flow rates indicated by RGO-HYTOS are based on the following features: closed by-pass valve at ν mm /s / 97 SUS element service life > operating hours at an average fluid contamination of.7 g per l/min /.7 g per gpm flow volume flow velocity in the connection lines. m/s /.8 ft/s Filling filter: Up to l/min /. gpm (see Selection Chart, column ). Connection Threaded ports according to ISO 8 or DIN SE standard J Sizes see Selection Chart, column 9, (other port threads on request). Filter fineness µm(c)... µm(c) β-values according to ISO 889 (see Selection Chart, column and diagram Dx). Dirt-holding capacity Values in g test dust ISO MTD according to ISO 889 (see Selection Chart, column ). Hydraulic fluids Mineral oil and biodegradable fluids (HEES and HETG, see info-sheet.). With high filling conditions we recommend an electrical conductivity ps/m at C / 8 F. Temperature range - C... + C (temporary - C... + C) - F... + F (temporary - F... +8 F) Viscosity at nominal flow rate at operating temperature: ν < mm /s / 8 SUS as starting viscosity: ν max = mm /s / SUS at initial operation: The recommended starting viscosity can be read from the diagram D (pressure drop as a function of the kinematic viscosity) as follows: Find the 7% p of the cracking pressure of the by-pass valve on the vertical axis. Draw a horizontal line so that it intersects the p curve at a point. Read this point on the horizontal axis for the viscosity. Operating pressure Max. bar / psi Mounting position referably vertical, outlet downwards. age 8

Diagrams p-curves for complete filters in Selection Chart, column Types w/o filling filter D ressure drop as a function of the flow volume at ν = mm /s / SUS ( = casing empty) ressure drop as a function of the kinematic viscosity at nominal flow Q [gpm].. 9..8. 79..,.,.,.,.,., E 8.7 7..8..9. ν [SUS] 97 8 78 78 7. 8.. 9.. Q [l/min] 8 ν [mm /s] D ressure drop as a function of the flow volume at ν = mm /s / SUS ( = casing empty) Q [gpm].. 9..8. 79.., E.,.,.,.,., 8.7 7..8..9. Q [l/min] ressure drop as a function of the kinematic viscosity at nominal flow ν [SUS] 97 8 78 78 8 ν [mm /s] 7. 8.. 9.. Types with filling filter D ressure drop as a function of the flow volume at ν = mm /s / SUS ( = casing empty) ressure drop as a function of the kinematic viscosity at nominal flow Q [gpm].. 9..8. 79.., 8.7.,.,.,.,., E 7..8..9. ν [SUS] 97 8 78 78 7. 8.. 9.. Q [l/min] 8 ν [mm /s] age 9

D ressure drop as a function of the flow volume at ν = mm /s / SUS ( = casing empty) Q [gpm].. 9..8. 79.., E.,.,.,.,., 8.7 7..8..9. Q [l/min] ressure drop as a function of the kinematic viscosity at nominal flow ν [SUS] 97 8 78 78 8 ν [mm /s] 7. 8.. 9.. Filter fineness curves in Selection Chart, column Dx Filtration ratio β for particles > x µm Filtration ratio β as a function of particle size x obtained by the Multi-ass-Test according to ISO 889 article size x [µm] (for particles larger than the given particle size x) Efficiency [%] The abbreviations represent the following ß-values resp. finenesses: For EXOR MX - and aper elements: EX = β (c) = EXOR MX 7EX = β 7 (c) = EXOR MX EX = β (c) = EXOR MX EX = β (c) = EXOR MX = β (c) = aper ased on the structure of the filter media of the paper elements, deviations from the printed curves are quite probable. For screen elements: S = screen material with mesh size µm S = screen material with mesh size µm S = screen material with mesh size µm Tolerances for mesh size according to DIN 89. For special applications, finenesses differing from these curves are also available by using special composed filter media. age

Selection Chart art No. Return filter Filling filter ressure drop see Diagram D/curve No. Dirt-holding capacity Filter fineness see diagr.dx Filter finenes filling filter / by-pass protection strainer Filter surface filling filter / by-pass protection strainer Connection Cracking pressure of by-pass Symbol Replacement filter element art No. l/min l/min g µm cm bar kg Ventilating filter thread connection M x Weight 7 8 9 E -9 8 - D/ EX 9 - - G¼. V7.8- -.7 E - - D/ EX - - G¼. V7.8- -.7 E -8 9 - D/ EX - - G¼. V7.8-8 -.7 E - - D/ - - G¼. 7.8- -.7 E -9 8 D/ EX 9 8 G¼. K7.8-. E - D/ EX 8 G¼. K7.8-. E -8 9 D/ EX 8 G¼. K7.8-8. E - D/ 8 G¼. K7.8-. E -9 - D/ EX - - G¼. V7.8- -. E - - D/ EX 7 - - G¼. V7.8- -. E -8 - D/ EX 7 - - G¼. V7.8-8 -. E - - D/ - - G¼. 7.8- -. E -9 D/ EX 8 G¼. K7.8-. E - D/ EX 7 8 G¼. K7.8-. E -8 D/ EX 7 8 G¼. K7.8-8. E - D/ 8 G¼. K7.8-. referred type, no minimum order quantity required t mm /s (ISO VG at ca. C / 9 F) aper media supported with metal gauze Open connection for ventilating filter. lease assemble ventilating filter before operating. Remarks ll filters are delivered with a plugged clogging indicator connection M x.. s clogging indicators either manometers or electrical pressure switches can be used. Optional extension pipes adapt the filter length to various tank depths. For ordering of accessories please use the below mentioned codes. Order example: The filter E - has to be supplied with an extension pipe for a mounting depth of mm. Order description: E - / EV art No. (asic unit) Extension pipe ( various lengths are available on request) E : EV, EV, EV, EV E : EV, EV, EV, EV For the appropriate ventilating filters with M x thread connection see catalogue sheet. and., for the appropriate clogging indicators see catalog sheet.. Remarks: The switching pressure of the electrical pressure switch has always to be lower than the cracking pressure of the by-pass valve (see Selection Chart, column ). Clogging indicators are optional and always delivered detached from the filter. The filters listed in this chart are standard filters. Other designs available on request. age

Selection Chart art No. Return filter Filling filter ressure drop see Diagram D/curve No. Filter fineness see diagr.dx Dirt-holding capacity Filter finenes filling filter / by-pass protection strainer Filter surface filling filter / by-pass protection strainer Connection / Cracking pressure of by-pass Symbol Replacement filter element art No. gpm gpm g µm inch SE psi lbs Remarks Ventilating filter thread connection M x Weight 7 8 9 E -79. - D/ EX 9 - - - /- V7.8- -.7 E -7 7. - D/ EX - - - /- V7.8- -.7 E -78. - D/ EX - - - /- V7.8-8 -.7 E -7. - D/ - - - /- 7.8- -.7 E -89.. D/ EX 9 - /- K7.8-. E -8 7.. D/ EX - /- K7.8-. E -88.. D/ EX - /- K7.8-8. E -8.. D/ - /- K7.8-. E -79. - D/ EX - - - /- V7.8- -. E -7 8. - D/ EX 7 - - - /- V7.8- -. E -78 8. - D/ EX 7 - - - /- V7.8-8 -. E -7 8. - D/ - - - /- 7.8- -. E -89.. D/ EX - /- K7.8-. E -8 8.. D/ EX 7 - /- K7.8-. E -88 8.. D/ EX 7 - /- K7.8-8. E -8 8.. D/ - /- K7.8-. referred type, no minimum order quantity required t 97 SUS (ISO VG at approx. C / 9 F) Corresponds to /8- UN- Corresponds to /- UN-, plugged with locking screw aper media supported with metal gauze Open connection for ventilating filter, please assemble ventilating filter before operating ll filters are delivered with a plugged clogging indicator connection M x. mm. s clogging indicators either manometers or electrical pressure switches can be used. Optional extension pipes adapt the filter length to various tank depths. For ordering of accessories please use the below mentioned codes. Order example: The filter E -7 has to be supplied with an extension pipe for a mounting depth of mm (resp. 9.9 inch). Order description: E -7 / EV art No. (asic unit) Extension pipe ( various lengths are available on request) E : EV (.8 inch), EV (. inch), EV (.7 inch), EV (8. inch) E : EV (7.9 inch), EV (9.9 inch), EV (. inch), EV (. inch) For the appropriate ventilating filters with M x thread connection see catalog sheet. and., for the appropriate clogging indicators see catalog sheet.. Remarks: The switching pressure of the electrical pressure switch has always to be lower than the cracking pressure of the by-pass valve (see Selection Chart, column ). Clogging indicators are optional and always delivered detached from the filter. The filters listed in this chart are standard filters. Other designs available on request. age

Dimensions Version without connection for ventilating filter Version with connection for ventilating filter Z I+(EV-K) N S Ventilating filter (not included in basic equipment) H G Ø E F Q H G ØE F U O-ring (included in basic equipment) Ø D Ø C EV K ØD ØC Dia hole in reservoir R Extension pipe on request Version with connection Connection M x. for clogging indicator O 9º 9º 9º X O O Required mounting surface L M W L C M N N W M Versions with connections on request 9º Connection M x with ventilating filter V N For dimension EV see selection chart N Y M Measurements in mm Type C min./max. D E F G H I K L M N O E G¼ G 8/ 9. 7 E G¼ G 8/ 9. 7 7 Type Q R S U V W X Y Z E 8. 8 7 8 E 8. 7 7 8 Measurements in inch Type C min./max. D E F G H I K L M N O E - -.9./.7.7.9....8 8.9...99. E - -.9./.7.7.9... 7.9....99. Type Q R S U V W X Y Z E.8.9...7.9.7.7. E.8.9...7.9.7.7. Corresponds to /8 - UN- Corresponds to / - UN- age

Symbols T T Spare arts 7 os. Designation art No. Screw-on cap with valve E. (. bar / psi) and os. Screw-on cap with valve E. (. bar / psi) and os. O-ring N7. x mm.9 x. inch Replacement filter element see Chart / col. Filter bowl E * E.9 Filter bowl E * E.9 O-ring N7.9 9 x mm. x. inch O-ring N7. x mm.9 x. inch 7 Connection for ventilating filter (incl. O-ring x mm /. x. inch) E.9 *Specify mounting depth (EV) in mm The functions of the complete filters as well as the outstanding features of the filter elements assured by RGO-HYTOS can only be guaranteed if original RGO-HYTOS spare parts are used. Quality ssurance Quality management according to DIN EN ISO 9 To ensure constant quality in production and operation, RGO-HYTOS filter elements undergo strict controls and tests according to the following ISO standards: ISO 9 ISO 9 ISO 9 ISO 98 ISO 889 ISO 8 Verification of collapse / burst pressure rating Verification of fabrication integrity (ubble oint Test) Verification of material compatibility with fluids Evaluation of pressure drop versus flow characteristics Multi-ass-Test (evaluation of filter fineness and dirt-holding capacity) Determination of resistance to flow fatigue using high viscosity fluid Various quality controls during the production process guarantee the leakfree function and solidity of our filters. Illustrations may sometimes differ from the original. RGO-HYTOS is not responsible for any unintentional mistake in this specification sheet. age