SCIENCE LAB UTILITY CONTROLS

Similar documents
Ventam 85 Installation & Commissioning Instructions

Gas Check. Short testing time, with automatic start-up if no leakage was detected from previous operation.

Tightness controls TC 1 3 and TC 4

BUBBLER CONTROL SYSTEM

BUBBLER CONTROL SYSTEM

PROVENGAS AUTOMATIC PROVING SYSTEMS FOR GAS INSTALLATION

EDUCATION DEPARTMENT ACCU-TEST

Tightness control TC. Product brochure GB 3 Edition AGA

TANKTRONIC. STANDARD CONFIGURATION Single Tank. ADVANCED CONFIGURATION Multiple Tanks. Twin Tank (common valve) Twin Tank (separate valves) Vent box

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

RAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

RAM 4021-DPX Operation Manual

RAM Operation Manual

Valve Proving System VDK 200 A S06*

INSTRUCTION MANUAL. FLOW CONTROL DRAWERS MANUAL / PLC CONTROL SERIES Model Version Perma Pure LLC Tel:

5 Channel Calibrator

Valve Proving System VDK 200 A S02

628 Differential Pressure Decay Leak Tester

HYPOXIC AIR FIRE PREVENTION SYSTEM TECHNICAL SPECIFICATION

SPECIFICATIONS ATTENTION

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

Flow and Energy Measurement F-5400 THERMAL MASS FLOW METER

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

ACV-10 Automatic Control Valve

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

MEDICAL EQUIPMENT CATALOG

RAM 4021 Operation Manual

Autocalibration Systems For In Situ Oxygen Analyzers

Miniature controls. Contactors. Overload relays. Starters. Control relays

NIV EAU MATIC ST User Manual Made in Canada

MASS FLOW SYSTEMS MASS FLOW MEASURING, CONTROLLING AND BLENDING SYSTEMS

Propane Conversion Kit Instruction

LT GasAnalyzer. LT GasAnalyzer Page 1 of 6

Automatic Valve Proving Control

Features. Description

DF-550E PROCESS ANALYSERS APPLICATIONS FEATURES

Propane Conversion Kit Instruction

Pro-V Multivariable Flowmeter Model M22 In-line Vortex

Manifolds & pressure reducing sets

X-Flow Mass Flow Controller 授权代理 : 北京品超思瑞科技学院公司

Instruction Manual VCG-6

Your local gas generation partner. Precision series Modular gas generation solution for GC.

CO, NO, NO 2, NO x, SO 2, CH 4, HCl, CO 2 & H ² O. Extractive low cost, low maintenance devices for continuous process and emissions monitoring.

Supplementary Operator s Manual 42/24-14 EN Rev. 3

780S Ultra High Purity Series

Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter

SCOPE OF THIS GUIDE STARTING-UP. 1 Check mini CORI-FLOW functional properties

analytical bulk flow distance FLOW level pressure temperature industrial communication

AutoChanger Installation & User Guide Issue 2

Stand-Alone Bubble Detection System

GA-300 Gas Analyzer. Technical Note. Overview. Front Panel. iworx Systems, Inc. GA-300

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units

Propane Conversion Kit Instruction

Table of Contents. Sensor Calibration and Troubleshooting CDS4000 CO 2. Introduction 1. Handling Information. Calibration 2.

ECS Protector Nitrogen Generator PGEN-30 (PGEN-30E)

TABLE OF CONTENTS TECHNICAL DOCUMENTATION 03

Discovery HP-TGA 75/750. Site Preparation Guide

O.K. Safety first CDN USA. Table of Contents. Approvals. Attention IFGC CSA UL ANSI NFPA

MOYNO FLUID DETECTION CONTROL SERVICE MANUAL. Section: ACCESSORIES. Page: 1 of 8 Date: May 1, 1998 GENERAL

Saab Seaeye Cougar XT Compact

Incorrect installation, adjustment, or misuse of this burner could result severe personal injury, or substantial property damage.

Net$ync II. Net$ync II. System Controllers

Plasma. Argon Production Helium Liquefaction Truck Loading Pure Gas Bottling

Aquavar SOLO 2 Frequently Asked Questions

EasyTouch. Because automation makes it all so simple. Pool and Spa Control Systems. By Pentair Water Pool and Spa

700 SERIES BMS II BUBBLER MONITORING SYSTEM

Transmitter CS 21 Operation Manual

SERVICE MANUAL MODEL BA600AMST-S1 BREATHING AIR PANEL

571 Series Medical TM. IntelliSwitch Electronic Switchover

Fio 2.2 Smart add-on for gas pressure Regulators

WATER MADE EASY MARINE ENERGY MUNICIPAL INDUSTRIAL

Fully Automatic Gas Manifold. Patent US 7,013,906. Installation & Operation Manual

OPERATING INSTRUCTIONS Sherlock Chamber Testing System

INSTALLATION OPERATION MAINTENANCE

Vehicle- or rack-mounted liquefied gas meters, pump supplied

Chemical Feed Equipment Floor-Mounted Gas Dispenser - Series CH4200

36E DSI and HSI Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS

Instructions for High Altitude Conversion

Safety Shutoff Valves MVD/6 Series MVDLE/6 Series

Digital Flow Switch. Series PFM7

CCT-7320/ROC-2313 Reverse Osmosis Controller

UBEC 1AT. AUTO TANK Fill System Installation, Operation, & Setup Instructions

SAPCON. User Manual. Capacitance Continuous Level Indicator. . Introduction. . General Description. . Principle of Operation. .

Control units. Installation and operating instructions Series: DP-Control

LT GasAnalyzer beyond standards

Conversion instructions from natural gas to propane

INSTALLATION & MAINTENANCE INSTRUCTIONS

Product Manual. Cyl-Tel and Tank-Tel Liquid Level Gauges. Designed and Built by: Chart Inc th Street NW New Prague, MN USA (800)

Series Environmental Chambers

CDS-2000 CO 2 Sensor Verification, Calibration, and Troubleshooting Bulletin

A versatile gas mixing system for blending LPG and air that is SAFE, RELIABLE, and EASY TO USE

SSL. Smart Valve Positioner.

AUTOMATIC GAS MANIFOLDS

GasLab SAN-102 Micro Oxygen Monitor User Manual

AFC. SDPROC and AFC Analog Mass Flow Controller ANALOG MASS FLOW CONTROLLERS. Principles of Operation. Design Features

Pro-V Multivariable Flowmeter

GEN-1e CO2 Generator OVERVIEW INSTALLATION PROPANE GENERATORS ONLY NATURAL GAS GENERATORS ONLY

eflo ELECTRONIC GAS FLOW METER OPERATIONS MANUAL

Best Practice Guide, Servomex 2700

USER S INFORMATION MANUAL

Transcription:

SCIENCE LAB UTILITY CONTROLS INCORPORATING GAS PRESSURE PROVING GAS PRESSURE PROVING EQUIPMENT - ENGINEERED TO DELIVER EXCEPTIONAL LEVELS OF SAFETY THE MERLIN RANGE DESIGNED FOR EDUCATIONAL LABORATORIES

AMERICAN GAS SAFETY GAS PRESSURE PROVING SYSTEMS FOR LABORATORY APPLICATIONS American Gas Safety is becoming North America s leading designer, manufacturer, and supplier of modern gas safety products. These include gas ventilation and gas interlock systems for use in commercial kitchens. We also design and manufacture our own gas pressure proving systems and gas detection systems for boiler houses and school science laboratories. American Gas Safety has 30 years of experience in the gas industry and has become the trusted name to provide gas safety and installation solutions to the commercial market. Our fully qualified engineers and designers keep up to date with industry practices and developments, adhering to all health and safety legislation, as well as, building codes. Therefore our customers can feel assured that the solutions we are providing along with the technical backup are second to none. American Gas Safety is a family run and operated business with excellent customer service and value for money at its core. Advantages Of Working with American Gas Safety LLC Full technical support available Competitively priced Complete After Sales Care Full product catalogue available at www.americangassafety.com UL Certified Factory and Products Easy installation Express delivery available nation wide Modern digital design Full product operating and maintenance available online. Meeting Gas Safety Standards Is Our Business And Our Passion The Merlin range of gas pressure proving systems we supply for laboratory control applications are the most up to date in the market. Whether is gas only, gas and bench electrics or gas, bench electrics and water you need to control we have the panel to meet your requirements. Designed to protect the students and teachers during lessons and the buildings out of ours, our panels have the added advantage of giving the teacher flexible and adjustable control over the classroom. The Merlin range of products have been designed to be easy to install and are very user friendly. All American Gas Safety panels come with a three year warranty as standard. The Merlin Range American Gas Safety - Head Office PAGE 2

CONTENTS FIND THE PANEL YOU NEED IN AN INSTANT Gas Proving System Gas Isolation Electrical Isolation Water Isolation Timeout Function Fire Alarm Interface Additional EM Stops Facility to Add CO2 Monitor 1000S PAGE 4 1000S+ PAGE 6 1000SW+ PAGE 8 PAGE 3

THE MERLIN RANGE 1000S SYSTEM The Merlin 1000S gas pressure proving system is designed specifically for use in School and University Laboratories. This panel is to be used to carry out a gas proving test on the pipe work in order to highlight if there is a gas appliance open or a gas leak in the laboratory. The Merlin 1000S is designed to give the teacher full control over the incoming gas supply with the lockable key-switch operation. The Merlin 1000S can work in conjunction with carbon dioxide, natural gas, carbon monoxide and LPG sensors. The Merlin 1000S also has a built in timeout facility which will automatically shut off the gas solenoid valve at the end of a specific time period, this time period can be adjusted to 2, 5, 8 hours or can be overridden if required. Advantages of the Merlin 1000S System Can work in conjunction with a Merlin CO2 Monitor. Protects people and property by testing for leaks before allowing the gas on. Reliable method of pressure proving using the gas pressure transducer. Key switch operation gives teacher full control. Quick proving test, typically 30 seconds from switch on to ready for use. Time out facility protects the building out of hours Low pressure indication, continual monitoring of gas pressure. Clear LED display for system indications. Compatible with both BMS and fire alarm systems. Additional sensors can be fitted to test for CO2, CO, Nat Gas, LPG Straightforward to install and calibrate, the Merlin 1000S can be easily adjusted to the user s requirements. Covered by American Gas Safety 3 year warranty PAGE 4

LABORATORY EQUIPMENT ENGINEERED FOR PEACE OF MIND Gas Pressure Transducer The gas pressure proving is carried out using our gas pressure transducer fixed into the downstream port of the gas solenoid valve. When the panel is switched to the on position the Merlin 1000S will begin to carry out a gas proving test. If the Merlin 1000S detects there is a drop in gas pressure, or a gas leak, within the 30 second start-up period, the gas solenoid valve will not be allowed to open and the panel will show test fail. If the gas line is found to be sound the panel will go to Gas on and the gas solenoid valve will open. At any time, whether during the testing procedure or when the gas solenoid valve is open, if the incoming gas pressure drops below 12mb, for more than 10 seconds, the gas valve will shut and the pressure low LED will illuminate and the gas solenoid valve will be closed. Time Out Another useful feature on the Merlin 1000S is the Time out facility, which is simple and straightforward to use. The Time out feature switches the gas supply off after a pre-set period ensuring that if the user should forget to switch the system off then the gas supply will automatically be isolated at the end of the Time out period. The Time out function can be set at 2, 5 or 8 hours and can be overridden if required. Carbon Dioxide Monitoring Along with the various additional gas sensors the Merlin 1000S system can also work in conjunction with our CO2 Monitor. The CO2 Monitor will constantly measure the air quality in the classroom and give the teacher and students a visual read out of the parts per million of CO2 in the air. If at any point the CO2 rose to an unsafe level of 2800ppm (according to current regulations), the Carbon Dioxide Monitor would send a signal to the Merlin 1000S which in turn would shut off the gas supply. The Merlin 1000S would show CO2 High on the LED display. The classroom would need to be ventilated before the CO2 Monitor would allow the Merlin 1000S to be re-set. Merlin 1000S System Wiring Diagram 1 2 3 4 5 6 7 8 9 1. Mains Input 120V Single Phase. 2. Gas Solenoid Valve Power Output, 120VAC, Max 3A. 3. BMS output contacts. Common, Normally Closed and Normally Open. Max.1A @ 120VAC. 4. Gas pressure transducer, power supply & returned signal 5. Remote EM Stop buttons and Fire Alarm input wired in series (purchased separately). VOLT FREE INPUT 6. Methane, CO or LPG Detector, power supply and volt free input (purchased separately). 7. Fan Switch output (purchased separately). 8. CO2 Monitor (purchased separately). VOLT FREE INPUT 9. Permanent 12VDC output. Merlin 1000S Box Dimensions Height 7 inches American Gas Safety has a full technical team available to help: Call us: +1 (727) 608 4375 or email: info@americangassafety.com Length Depth 10 inches 2.5 inches Americangassafety.com PAGE 5

THE MERLIN RANGE 1000S+ SYSTEM The Merlin 1000S+ gas and electric isolation system with gas pressure proving is designed specifically for use in School and University Laboratories. This panel will carry out a gas proving test on the pipe work in order to highlight an open gas appliance or a gas leak in the laboratory. The Merlin 1000S+ is designed to give the teacher full control over the incoming gas supply and bench electrics with the lockable main key-switch & touch sensor controls. The Merlin 1000S+ can work in conjunction with carbon dioxide, natural gas, carbon monoxide and LPG sensors. The Merlin 1000S+ also has a built in timeout facility which will automatically shut off the gas solenoid valve at the end of a specific time period, this time period can be adjusted to 2, 5, 8 hours or can be overridden if required. Advantages of the Merlin 1000S+ System Can work in conjunction with a Merlin CO2 Monitor. Protects people and property by testing for leaks before allowing the gas on. Reliable method of pressure proving using the gas pressure transducer. Key switch and touch sensors gives teacher full control of both gas supply and bench electrics. Quick proving test, typically 30 seconds from switch on to ready for use. Time out facility protects the building out of hours Low pressure indication, continual monitoring of gas pressure. Clear LED display for system indications. Compatible with both BMS and fire alarm systems. Straightforward to install and calibrate, the Merlin 1000S+ can be easily adjusted to the user s requirements. Covered by American Gas Safety 3 year warranty PAGE 6

LABORATORY EQUIPMENT ENGINEERED FOR SAFETY Touch Sensor Control When the key switch is turned to the on position the user then has 10 seconds to select the facilities they would like to use. At the end of the 10 seconds whichever facilities have been selected will be activated. If the user wishes to disable any of these facilities or use any other facilities they would have to turn the key switch to the off position and then back to the on position and the process will have to be repeated. Gas Pressure Transducer The gas pressure proving is carried out using our gas pressure transducer fixed into the downstream port of the gas solenoid valve. When the panel is switched to the on position the Merlin 1000S+ will begin to carry out a gas proving test. If the Merlin 1000S+ detects there is a drop in gas pressure, or a gas leak, within the 30 second start-up period, the gas solenoid valve will not be allowed to open and the panel will show test fail. If the gas line is found to be sound the panel will go to Gas on and the gas solenoid valve will open. At any time, whether during the testing procedure or when the gas solenoid valve is open, if the incoming gas pressure drops below 12mb, for more than 10 seconds, the gas valve will shut and the pressure low LED will illuminate and the gas solenoid valve will be closed. Time Out Another useful feature on the Merlin 1000S+ is the Time out facility, which is simple and straightforward to use. The Time out feature switches the gas supply off after a pre-set period ensuring that if the user should forget to switch the system off then the gas supply will automatically be isolated at the end of the Time out period. The Time out function can be set at 2, 5 or 8 hours and can be overridden if required. Carbon Dioxide Monitoring Along with the various additional gas sensors the Merlin 1000S+ system can also work in conjunction with our CO2 Monitor. The CO2 Monitor will constantly measure the air quality in the classroom and give the teacher and students a visual read out of the parts per million of CO2 in the air. If at any point the CO2 rose to an unsafe level of 2800ppm (according to current regulations), the Carbon Dioxide Monitor would send a signal to the Merlin 1000S+ which in turn would shut off the gas supply. The Merlin 1000S+ would show CO2 High on the LED display. The classroom would need to be ventilated before the CO2 Monitor would allow the Merlin 1000S+ to be re-set. Merlin 1000S+ System Wiring Diagram 1 2 3 4 5 6 7 8 9 10 1. Mains Input 120V Single Phase. 2. Gas Solenoid Valve Power Output, 120VAC, Max 3A. 3. Electric Contactor Power Output, 120VAC, Max 3A. 4. BMS output contacts. Common, Normally Closed and Normally Open. Max.1A @ 120VAC. 5. Gas pressure transducer, power supply & returned signal 6. Remote EM Stop buttons and Fire Alarm input wired in series (purchased separately). VOLT FREE INPUT 7. Methane, CO or LPG Detector, power supply and volt free input (purchased separately). 8. Fan Switch output (purchased separately). 9. CO2 Monitor (purchased separately). VOLT FREE INPUT 10. Permanent 12VDC output. Merlin 1000S+ Box Dimensions American Gas Safety has a full technical team available to help: Call us: +1 (727) 608 4375 or email: info@americangassafety.com Height Length Depth 7 inches 10 inches 2.5 inches Americangassafety.com PAGE 7

THE MERLIN RANGE 1000SW+ SYSTEM The Merlin 1000SW+ gas, electric & water isolating system with gas pressure proving is designed specifically for use in school and University Laboratories. This panel will carry out a gas proving test on the pipe work in order to highlight an open gas appliance or a gas leak in the laboratory. The Merlin 1000SW+ is designed to give the teacher full control over the incoming gas supply, bench electrics and basin water supply with the lockable main key-switch & touch sensor controls. The Merlin 1000SW+ can work in conjunction with carbon dioxide, natural gas, carbon monoxide and LPG sensors. The Merlin 1000SW+ also has a built in timeout facility which will automatically shut off the gas solenoid valve at the end of a specific time period, this time period can be adjusted to 2, 5, 8 hours or can be overridden if required. Advantages of the Merlin 1000SW+ System Can work in conjunction with a Merlin CO2 Monitor. Protects people and property by testing for leaks before allowing the gas on. Reliable method of pressure proving using the gas pressure transducer. Key switch and touch sensors gives teacher complete control all facilities in the classroom. Quick proving test, typically 30 seconds from switch on to ready for use. Time out facility protects the building out of hours Low pressure indication, continual monitoring of gas pressure. Clear LED display for system indications. Compatible with both BMS and fire alarm systems. Straightforward to install and calibrate, the Merlin 1000SW+ can be easily adjusted to the user s requirements. Covered by American Gas Safety 3 year warranty PAGE 8

LABORATORY EQUIPMENT ENGINEERED TO PROTECT Touch Sensor Control When the key switch is turned to the on position the user then has 10 seconds to select the facilities they would like to use. At the end of the 10 seconds whichever facilities have been selected will be activated. If the user wishes to disable any of these facilities or use any other facilities they would have to turn the key switch to the off position and then back to the on position and the process will have to be repeated. valve will shut and the pressure low LED will illuminate and the gas solenoid valve will be closed. Water Isolation The Merlin 1000SW+ system has the facility to control a solenoid valve allowing control over the water supply to the classroom. If the Water LED is illuminated the system will power the water solenoid valve and give the classroom access to the water supply. Gas Pressure Transducer The gas pressure proving is carried out using our gas pressure transducer fixed into the downstream port of the gas solenoid valve. When the panel is switched to the on position the Merlin 1000SW+ will begin to carry out a gas proving test. If the Merlin 1000SW+ detects there is a drop in gas pressure, or a gas leak, within the 30 second start-up period, the gas solenoid valve will not be allowed to open and the panel will show test fail. If the gas line is found to be sound the panel will go to Gas on and the gas solenoid valve will open. At any time, whether during the testing procedure or when the gas solenoid valve is open, if the incoming gas pressure drops below 12mb, for more than 10 seconds, the gas Carbon Dioxide Monitoring Along with the various additional gas sensors the Merlin 1000SW+ system can also work in conjunction with our CO2 Monitor. The CO2 Monitor will constantly measure the air quality in the classroom and give the teacher and students a visual read out of the parts per million of CO2 in the air. If at any point the CO2 rose to an unsafe level of 2800ppm (according to current regulations), the Carbon Dioxide Monitor would send a signal to the Merlin 1000SW+ which in turn would shut off the gas supply. The Merlin 1000SW+ would show CO2 High on the LED display. The classroom would need to be ventilated before the CO2 Monitor would allow the Merlin 1000SW+ to be re-set. Merlin 1000SW+ System Wiring Diagram 1 2 3 4 5 6 7 8 9 10 11 1. Mains Input 120V Single Phase. 2. Gas Solenoid Valve Power Output, 120VAC, Max 3A. 3. Electric Contactor Power Output, 120VAC, Max 3A. 4. Water Solenoid Valve Power Output, 120VAC, Max 3A. 5. BMS output contacts. Common, Normally Closed and Normally Open. Max.1A @ 120VAC. 6. Gas pressure transducer, power supply and returned signal 7. Remote EM Stop buttons and Fire Alarm input wired in series (purchased separately). VOLT FREE INPUT 8. Methane, CO or LPG Detector, power supply and volt free input (purchased separately). 9. Fan Switch output (purchased separately). 10. CO2 Monitor (purchased separately). VOLT FREE INPUT 11. Permanent 12VDC output. Merlin 1000SW+ Box Dimensions Height 7 inches American Gas Safety has a full technical team available to help: Call us: +1 (727) 608 4375 or email: info@americangassafety.com Length Depth 10 inches 2.5 inches Americangassafety.com PAGE 9

THE MERLIN RANGE CO2 MONITOR The Merlin CO2 Monitor is designed specifically for use with the Merlin range of safety panels. The Merlin CO2 monitor has a LED display showing the user a clear and precise reading of the CO2 levels in a classroom. A traffic light color code system shows the user, at a quick glance, that the air quality in the room is at a safe, adequate, or dangerous level. The Merlin CO2 Monitor is a hard wire, 120V powered unit and can be used independently or in conjunction with one of the Merlin gas safety systems. In the event of high CO2 levels the Merlin CO2 Monitor would sound an audible alarm to alert the immediate vicinity, and send a signal to the gas safety panel (if fitted) which in turn will close the gas supply solenoid valve. The Merlin CO2 Monitor does not require on site or on-going calibration. Key Features of the Merlin CO2 Monitor Clear digital readings of the CO2 levels. Can work independently or in conjunction with Merlin Gas Interlock System Audible alarm alerts user of dangerous levels Can be easily wall mounted Easy Installation Traffic light warning system very easy to understand Does not require additional or on-going calibration Covered by American Gas Safety Ltd 3 year warranty PAGE 10

ANCILLARY PRODUCTS FROM AMERICAN GAS SAFETY Gas Solenoid Valve We only supply the best quality Gas Solenoid Valves which are design for safety and the control of various gases, including Natural gas, Propane and LPG. They are safety shut off valves Normally closed, so when power is supplied to the gas solenoid valve it will automatically open and as soon as that power is taken away the gas solenoid valve will close. The valves supplied are all covered by the American Gas Safety 3 year warranty and are tested and certified to UL standards. The valves are also rated to IP65 thus allowing them to be deployed in wet or dirty environments. Merlin Gas Detector Range American Gas Safety supplies a full range of remote gas detectors for detecting CO, CO2, natural gas and LPG to compliment the Merlin range of panels. The detectors are designed using modern European digital components. If the relative gas is detected on the sensor head this will trigger the isolation of the power supply to the solenoid and isolate the gas supply. This can then be rectified by resolving the leak, allowing the sensor head to clear and resetting the attached Merlin panel. There is no need for on-site calibration or re-calibration saving time and money. Emergency Knock-Off Button We only supply the highest quality emergency knock-off buttons for increased longevity and reliability. The Emergency Knock-off button s can either be twist release type, twist key release type or use a resettable Perspex screen, whichever the governing code stipulates. Once the EM stop button has been depressed the Merlin panel will not function until the system has been reset both at the button and on the unit. There is no limit to the number of additional EM stops that can be fitted per Merlin panel and they are connected with low voltage cabling. PAGE 11

SCAN WITH YOUR SMART PHONE TO VIEW OUR FULL LAB RANGE ONLINE FOR OUR FULL RANGE OF PRODUCTS & SERVICES - VISIT US AT WWW.AMERICANGASSAFETY.COM W: WWW.AMERICANGASSAFETY.COM AGS HEAD OFFICE: +1 (727) 608 4375 4500 140TH AVENUE NORTH SUITE 101 CLEARWATER FL 33762 FAX: +1 (727) 538 4237 E: INFO@AMERICANGASSAFETY.COM