Series RM/ End lock RME Port Plug End block End block type Mounting position L Left side R Right side L side end block 0. L VVQ0000 Single unit regulator / Port plug for regulator block ø0 0 Options Note ) Since the L side end block is oil-free, leave the field blank for it. R side end block 0. Options Pressure Gauge GC--0 GC-0-0 GC-P-0 GC-P0-0 Specifications ushing mbient and fluid temperature Display accuracy Calibration angle Limit indicator -S -K Pressure gauge indication range 0 to 0. MPa 0 to.0 MPa 0 to 0 PSI 0 to 0 PSI ir - to 0 C Indication unit MPa PSI ±%F.S. (Full Span) 0 With limit indicator Common supply bushing Individual supply bushing -S -K - OPEN COVER.. ø. - 9
How to Order RM0 0 Z. IN/OUT fitting type Metric size Inch size Straight Elbow Straight Elbow Straight Elbow Straight Elbow ø ø ø ø ø ø ø ø ø/ ø/ ø/ ø/ ø/ ø/ ø/ ø/ 0 0 0 9 9 0 0. ccessory G P G GP racket Note ) Note ) Pressure gauge ( ) ( ) racket Note ) In case of a type with bracket, the panel nut is included. Note ) Pressure gauges are not available with the copper-free specification.. Unit representation Relief type Regulator Single Unit Type Series RM0 Display unit for product name plate and pressure gauge: MPa Z Note) Display unit for product name plate and pressure gauge: PSI Note) This product is for overseas use only according to the new Measurement Law. (The SI unit type is provided for use in Japan.) Non-relieving type Pressure gauge Specifications. Option Straight Elbow 0. MPa Note ) setting Note ) Non- relieving Note ) pressure gauge with a full span of 0. MPa is attached. Note ) The oil-free type has non-greased fluid contact areas. Model RM0 Regulator construction Direct acting Working principal Diaphragm regulator Relief type Relief mechanism Optional Non-relieving type ackflow function Within (Unbalance type) tubing O.D. ø, ø, ø/, ø/ tubing O.D. ø, ø, ø/, ø/ Proof pressure.mpa Maximum operating pressure.0mpa 0.0 to 0.MPa Regulating pressure range Optional 0.0 to 0.MPa (Low pressure type) ir mbient and fluid temperature to 0 C 0g Note) When the regulator is used with backflow, operate at a set pressure of 0. MPa or above. 0
Series RM0. IN/OUT piping position. ccessory Note ) racket RM0F 0 Note ) Pressure gauge Display cover ( GP ) G ( GP ) Note ) GPC Note ) In case of a type with bracket, the panel nut is included. Note ) Pressure gauges are not available with the copper-free specification. Note ) Please note that the dimensions will be big when GPC is required. Front handle type ottom Top ottom Top Panel Display cover Top How to Order Top ottom Display cover ottom. IN/OUT fitting types Metric size Inch size Straight Elbow Straight Elbow Straight Elbow Straight Elbow ø ø ø ø ø ø ø ø ø/ ø/ ø/ ø/ ø/ ø/ ø/ ø/ 0 0 0 9 9 0 0 Pressure gauge racket Z Example of panel mounting
. Options 0. MPa Note ) setting Note ) Non- relieving Note ) pressure gauge with a full span of 0. MPa is attached. Note ) The oil-free type has non-greased fluid contact areas. Specifications. Unit representation Model RM0F Regulator construction Direct acting Working principal Diaphragm regulator Relief type Relief mechanism Optional Non-relieving type ackflow function Within (unbalance type) tubing O.D. ø, ø, ø/, ø/ tubing O.D. ø, ø, ø/, ø/ Proof pressure.mpa Maximum operating pressure.0mpa 0.0 to 0.MPa Set pressure range Optional 0.0 to 0.MPa (Low pressure type) ir mbient and fluid temperature to 0 C g Note) When the regulator is used with backflow regulator, operate at a set pressure of 0. MPa or above. Regulator Single Unit Type Display unit for product name plate and pressure gauge: MPa Z Note) Display unit for product name plate and pressure gauge: PSI Note) This product is for overseas use only according to the new Measurement Law. (The SI unit type is provided for use in Japan.) Series RM0
Series RM0 Flow Rate Characteristics RM0F -0 RM0-0 (One-touch fittings: IN/OUT ø) RM0F -0 RM0-0 (One-touch fittings: IN ø, OUT ø) RM0F -0 RM0-0 (One-touch fittings: IN/OUT ø) Pressure Characteristics RM0F -0 RM0-0 0. 0. 0. 0. 0. 0. 0. 0 0 0 00 0 Inlet pressure 0.MPa 0. 0. 0. 0. 0. 0. 0. 0 0 0 00 0 RM0F -0- RM0-0- (One-touch fittings: IN/OUT ø) RM0F -0- RM0-0- (One-touch fittings: IN ø, OUT ø) 0. 0.0 0. 0.0 0. 0.0 0.0 0.00 0 0 0 0 0 00 RM0F -0- RM0-0- (One-touch fittings: IN/OUT ø) Inlet pressure 0.MPa Inlet pressure 0.MPa 0. 0. 0. 0. 0. 0. 0. 0 0 0 00 0 00 0 00 0. 0.0 0. 0.0 0. 0.0 0.0 0.00 0 0 00 0 00 0.0 0. 0.0 0. Flow rate l/min(nr) Flow rate l/min(nr) Flow rate l/min(nr) Inlet pressure 0.MPa Conditions: Inlet pressure 0.MPa Outlet pressure 0.MPa Flow rate 0l/min (NR) 0.0 0. 0. 0. 0. 0. 0. 0. 0.9.0 Inlet pressure MPa Inlet pressure 0.MPa 0. 0.0 0. 0.0 0. 0.0 0.0 0.00 0 0 0 0 0 00 RM0F -0- RM0-0- 0. 0.0 0. Flow rate l/min(nr) Flow rate l/min(nr) Flow rate l/min(nr) Inlet pressure 0.MPa Conditions: Inlet pressure 0.MPa Outlet pressure 0.MPa Flow rate 0l/min (NR) Set point Set point 0.0 0. 0. 0. 0. 0. 0. 0. 0.9.0 Inlet pressure MPa
Construction Parts list No. 9 ody onnet Handle Valve seat Dimensions djusting screw assembly djustment spring Regulator clip lanking plate assembly Square nut RM0-0 0 E D C F 9 RM0. PT PT POM POM Reinforced steel Steel wire Stainless steel 9. Steel (Max.) IN PUSH G Replacement parts LOCK OUT No. C D E F G Through hole for M ø. Diaphragm assembly Valve Valve spring O-ring O-ring O-ring Fitting assembly Regulator Single Unit Type F Panel cutout dimensions ø Plate thickness: Max.. 0. Weatherproof NR, POM HNR, luminum alloy Stainless steel NR NR NR Series RM0 RM0F D -0 Refer to page. For dimensions and accessories of One-touch fittings, please refer to page. 9 E C G
Series RM0 Dimensions RM0F- 0 0 RM0F- 0GPC 0GPC OUT IN OUT ø0 IN IN OUT 0 PUSH ø0 0 0. 0. PUS H OUT OPEN MPa 0. LOC K 0. LOC K IN Through hole for M ø. Panel cutout dimensions -R or less (Max.) to. ø Plate thickness: Max.. Panel cutout dimensions -R or less to. ø Plate thickness: Max.. (Max.)
Pressure Gauge GC--0 GC-0-0 GC-P-0 GC-P0-0 Specifications Panel Nut Regulator mbient and fluid temperature Display accuracy Calibration angle Limit indicator OPEN Display Cover Single Unit Options COVER POM g PT 0.g Pressure gauge indication range Indication unit 0 to 0.MPa 0 to.0mpa 0 to 0PSI 0 to 0PSI ir - to 0 C ±%F.S. (Full Span) 0 With limit indicator. g. (Width across flats of equilateral octagon) ø. MPa PSI ø. 0 One-touch Fittings for Regulator VVQ000-0 One-touch fittings for regulator Straight type Elbow type racket. Straight type Elbow type Fitting types Straight L C ø C N N RM0 RM0F ø ø/ ø/ Nickel plated steel g Elbow.. ø, ø/ ø ø/ ø, ø/ ø ø/ ø, ø/ ø ø/ ø, ø/ C Options 0. Y Y ø ø/ 0 0. 0. 0. 0.... R. ø Y.. Y.. (R)
Specifications How to Order Dimensions Regulator Single Unit Front Handle Type Series RM0F Made to Order Contact P/ regarding detailed specifications, demensions and delivery. Regulator construction Direct acting Working principal Diaphragm regulator Relief type Relief mechanism Optional Non-relieving type ackflow function Within (Unbalance type) IN/OUT air passage diameter ø IN/OUT gasket sealing O.D. ø Proof pressure.mpa Maximum operating pressure.0mpa 0.0 to 0.MPa Set pressure range Optional 0.0 to 0.MPa (Low pressure type) ir mbient and fluid temperature to 0 C g Note ) Mounting bolts and O-rings ( of each) are attached. Note ) When the regulator is used with backflow, operate at a set pressure of 0. MPa or above. RM0F. ccessory. Unit representation Without pressure gauge With pressure gauge Z Display unit for product name plate and pressure gauge: MPa Z Note) Display unit for product name plate and pressure gauge: PSI Note) This product is for overseas use only according to the new Measurement Law. (The SI unit type is provided for use in Japan.) Regulator single unit front handle type/ for manifold (Max.0) IN OUT ø0 PU SH LO C K 0 For manifold. Option Holding screw M x 0. x 0 Note ) 0. MPa Nonrelieving Note ) setting Note ) pressure gauge with a full span of 0. MPa is attached. Note ) The oil-free type has non-greased fluid contact areas. IN OUT Made to Order Example O-ring size ø x.w Need to prepare manifold base. 9