id-size Venturi Vacuum Pump with Interchangeable Cartridges and Silencer Ideal Applications: VP20/ VP20BV Standard Pump: VP20 id Series air-powered venturi vacuum pumps are the most commonly used pumps for pick & place applications due to their ease of mounting and the variety of options and accessories available. Vaccon id Series vacuum pumps provide maximum design versatility: designers specify only the features necessary for their specific application. VP20BV offers a 2-way integrated valve. Vaccon s interchangeable venturi cartridge system enhances manufacturing flexibility, enabling designers to choose the vacuum level, vacuum flow, evacuation speed and air consumption based on any one of 11 venturi cartridges. Performance evel Designations: 0-10 g [0 to 339mbar] for low vacuum/high flow applications 0-20 g [0 to 677mbar] for medium vacuum/high flow applications 0-28 g [0 to 948mbar] for high vacuum/standard flow applications VP20-90 pump with SX-5 switch monitors presence of box. No filters required. VP20BV-150 with optional ports for vacuum gauge and sensor/switch Features/Benefits: interchangeable venturi cartridges leakage providing a strong holding force and lighweight up to 28 g [948mbar] vacuum point ~ Straight-through design, non-clogging ~ No moving parts to wear or clog ~ No flap valves to stick open ~ No maintenance ~ No downtime Pump Options: control systems 2-way Integrated valve - 24vdc, normally closed vacuum sensor and troubleshooting for ultra quiet operation with metric threads 80 PSI [5.5 BAR] standard, 60 PSI [4.0 BAR] option) Principles of Operation: Vacuum is produced by forcing compressed air through a limiting orifice (nozzle). As the air exits the orifice, it expands, increasing in velocity to supersonic speed before entering the venturi section (diffuser). This creates a vacuum at the vacuum inlet port, located between the nozzle and diffuser. The nozzle and diffuser combine to create a venturi vacuum cartridge. Air Supply Vacuum Exhaust Vacuum Eliminate the Guesswork: Contact s! Vacuum technology isn t an exact science. To ensure proper product selection, Vaccon offers free application engineering assistance, a 30 Day Test & Evaluation Program or you can send sample products to our in-house test facility and we will test and size a pump for you. To download a complete set of drawings in 13 different CAD formats, please visit our website at www.vaccon.com For more information or technical assistance, please call 508-359-7200 or 800-848-8788 or email engineering@vaccon.com 66
VP20- (60, 90, 100, 150) (,, ) id Series Configurations and Options: All Vaccon pumps offer a variety of options and accessories to meet your specific requirements. Please configure your pump from the options listed below. VG-150 Supply Port NPT or Threads Valve Assembly Cartridge Assembly (nozzle & diffuser) AA4 Silencer (standard) ST4 Silencer STAA4 Silencer Optional Switches/Sensor w/quick Disconnect VSN-QD-6 6 pigtail & QD VSP-QD-6 6 pigtail & QD VTV-QD-6 6 pigtail & QD Adjustable echanical Switch SX-4 SX-5 ow to Specify: VP20 VP20BV Imperial Thread-NPT No Valve with Valve Assy etric Thread-G Port I-VP20 No Valve I-VP20BV with Valve ax. Flow evel 60 (Not Available in ) 90 100 150 VP20-60 - 60 - ST4 - VSP-QD-6 Switch/Sensor None (Standard) VSN-QD-6 Switch NPN with QD VSP-QD-6 Switch PNP with QD VTV-QD-6 Sensor 1-5VDC Output w/qd SX-4 Switch 2-14.8"g SX-5 Switch 7.4-30"g ST4 STAA4 VP20 pumps are Fractional and etric T-Slot compatible. See EOAT Section. Silencer AA4 - Closed End (Standard) Straight-Through ybrid ax. Vac evel 10"g [339mbar] 20"g [677mbar] 28"g [948mbar] Operating Pressure 80 PSI [5.5 Bar] (Std) 60 60 PSI [4.0 Bar] For complete Performance Data, see page 102. VG-150 Vacuum Gauge Vaccon does not recommend shipping gauges attached to pumps. Please specify as a separate line item. 67
Standard Pump: VP20 - (60, 90, 100, 150) (,, ) STAA4 SIENCER Standard VP20-90 with AA4 sliencer SETPOINT ADJ. (VSP, VSN ONY) 'Y' AX. VAC PORT F 'A' AIR SPPY PORT AA4 SIENCER E R 'C' EXAST PORT J K P S N T 3X 'D' ONTING OES 5 AX. VAC PORT ST4 SIENCER Specifications: Standard VP20-90 Weight: 5.1 oz [146g] Noise evel: 64dB V W 'B' VAC PORT Imperial Dimensions (in.) VP20 A B C D E F J K N P R S T V W Y 4.59 w/st4 5.06 w/staa4 1/4 1/4 1/4 0.21 1.50 3.46 0.75 0.38 0.75 0.20 2.75 0.23 1.10 1.65 3.20 6.31 1/8 0.38 1.1 w/vsp-qd-6, NPT F NPT F NPT F NPT F VTV-QD-6, 1.49 etric Dimensions (mm) I- VP20 A B C D E F J K N P R S T V W Y 116.59 w/st4 128.52 w/staa4 5.33 38.10 87.88 19.05 9.53 19.05 5.08 69.85 5.84 27.94 41.91 81.28 160.27 w/vsp-qd-6, 9.53 27.94 VTV-QD-6 37.85 68
Standard Pump: VP20BV - (60, 90, 100, 150) (,, ) Standard VP20BV-90 with AA4 silencer 'A' AIR SPPY PORT STAA4 SIENCER POWER CONNECT EADS 24 AWG (.51mm) BK -24VDC RED +24VDC J SETPOINT ADJSTENT 180 (VSP & VSN ONY) 'Y' AX. VAC PORT 'C' EXAST PORT F AA4 SIENCER E K R P S 3X 'D' ONTING OES N T 5 AX. VAC PORT ST4 SIENCER Specifications: Standard VP20BV-90 Weight: 8.1 oz [229.6g] Noise evel: 64dB W V 'B' VAC PORT Imperial Dimensions (in.) VP20BV A B C D E F J K N P R S T V W Y 7.75 w/ ST4 8.22 w/staa4 1/4 1/4 1/4 0.21 1.50 3.46 3.45 0.59 0.75 0.20 2.75 1.76 1.10 1.65 4.73 9.47 1/8 0.38 2.63 w/vsp-qd-6, NPT F NPT F NPT F NPT F VTV-QD-6, 1.49 etric Dimensions (mm) I- VP20BV w/ A B C D E F J K N P R S T V W Y 196.85 w/st4 208.79 w/staa4 5.33 38.10 87.88 87.63 14.94 19.05 5.08 69.85 5.84 27.94 41.91 81.28 240.54 w/vsp-qd-6, 9.53 66.80 VTV-QD-6, 37.85 69
VP20 Pump Standard Specifications: Pump aterial: Anodized Aluminum (For silencer material, see page 264-266) Cartridge aterial: Nylon, Buna-N O-ring (Other materials available, see page 8) edium: Filtered (50 icron) un-lubricated, non-corrosive dry gases Operating Temperature: -30 ~250 F [-34 ~121 C] Operating Pressure: 80 PSI [5.5 BAR] standard or 60 PSI [4.0 BAR] Consult Factory for other operating pressures Optional 2-Way Valve Specifications: Valve Type: Base ounted 2-Way, Solenoid Valve, Normally closed Valve Body aterial: Brass, Aluminum, Buna-N Valve Operating Pressure: Vacuum to 120 psi [-1 to 8 bar] Electrical: 24 VDC [-15% to +10% Nominal] Average ife: 100 million cycles or better Power Consumption: 4 watts Response Time: 6 milliseconds Cycle Rate: 80 cycles/second Electrical Connection: ED Indicator: Yes VP20 Operating and Installation Requirements: Cartridge size: C60 (, ) and C90 (,, ) C100 (,, ) and C150 (,, ) Supply ine: 1/4 O.D. [6mm] tube recommended 3/8 O.D. [10mm] tube recommended Vacuum ine: 1/4 O.D. [6mm] tube recommended 3/8 O.D. [10mm] tube recommended Vacuum ine Filtration: Control Valve: 3 way/2 position (faster part release), minimum orifice 0.125 ID [3mm] ounting oles: ounting holes accept 10-32 or 5 screws 70