Valve Communication Solutions Axiom

Similar documents
Series 3730 and Series 3731 EXPERTplus Valve Diagnostics with Partial Stroke Test (PST)

Data Sheet T 8389 EN. Series 3730 and 3731 Types , , , and. EXPERTplus Valve Diagnostic

Life Cycle Benefits: Maintenace (Control Valve Diagnostic and Field Device Diagnostic Management)

BUBBLER CONTROL SYSTEM

USER MANUAL. Intelligent Diagnostic Controller IDC24-A IDC24-AF IDC24-AFL IDC24-F IDP24-A * IDP24-AF * IDP24-AFL * IDP24-F * 1/73

The benefits of the extended diagnostics feature. Compact, well-proven, and flexible

BUBBLER CONTROL SYSTEM

2600T Series Pressure Transmitters Plugged Impulse Line Detection Diagnostic. Pressure Measurement Engineered solutions for all applications

Specifications and information are subject to change without notice. Up-to-date address information is available on our website.

Partial Stroke Testing for SRD991 and SRD960

Positioner type Smart Valve Positioner with diagnostic functions. Presented By: Mr. Gourishankar Saharan. Product management Jens Bargon / V42

Model EXAxt AV550G. Averaging Oxygen Analyzer

ACV-10 Automatic Control Valve

Time-Delay Electropneumatic Applications

PositionMaster EDP300 Extended Diagnostics. Compact, well-proven, and flexible

A Planning Guide for Effective Use HART Implementations. December 2012 (D103278X012)

PREDICTING HEALTH OF FINAL CONTROL ELEMENT OF SAFETY INSTRUMENTED SYSTEM BY DIGITAL VALVE CONTROLLER

FLUID POWER FLUID POWER EQUIPMENT TUTORIAL OTHER FLUID POWER VALVES. This work covers part of outcome 2 of the Edexcel standard module:

TECHNICAL DATA SINGLE INTERLOCKED PREACTION SYSTEM WITH PNEUMATIC RELEASE

Touch Screen Guide. OG-1500 and OG Part # T011

Competence in Functional Safety

Operating Instructions EB EN. Series 373x Electropneumatic Positioner Type 373x-5 EXPERT + with FOUNDATION fieldbus communication

Neles ValvGuard VG9000H Rev 2.0. Safety Manual

EXPERIMENT 1 AIR PRESSURE CONTROL SYSTEM

A TECHNICAL REFERENCE

TR Electronic Pressure Regulator. User s Manual

INSTALLATION OPERATION MAINTENANCE

2600T Series Pressure Transmitter Models 264DC Differential and 264HC Gage Level Transmitters. Kent-Taylor

Electrical Solutions Corporation 2368 Eastman Ave, Suite 13, Ventura, CA Phone (805) ~ Fax (805)

Service Test Unit for ROSS Proportional Valves RESK

SSL. Smart Valve Positioner.

Valve Communication Solutions. Safety instrumented systems

Four common PRESSURE CALIBRATION PAIN POINTS

RESILIENT SEATED BUTTERFLY VALVES FUNCTIONAL SAFETY MANUAL

Fisher DVI Desuperheater Venturi Inline

The Discussion of this exercise covers the following points:

Device Description User Manual Logix 520MD Positioners

The Ins and Outs of I/P Transducers

PART 5 - OPTIONS CONTENTS 5.1 SYSTEM EXPANSION 5-3

ATM 322 Basic Pneumatics H.W.6 Modules 5 7

MWEA MAINTENANCE SEMINAR SPECIALTY VALVES POWER GLOBES

Double whammy: the benefits of valve signatures and partial stroke testing

Fisher FIELDVUE DVC6200f Digital Valve Controller PST Calibration and Testing using ValveLink Software

Ultima. X Series Gas Monitor

A4s Operation Manual

4.5 Diagnosis Diagnosticdisplay. Operation

TECHNICAL DATA. Q = C v P S

Additel761 Series Firmware Updates

Fisher DSA Steam-Atomized Desuperheater

ACCURATE PRESSURE MEASUREMENT FOR STEAM TURBINE PERFORMANCE TESTING

Universal Valve Company Inc

TECHNICAL DATA. Q = C v P S

INSTALLATION & MAINTENANCE INSTRUCTIONS

I T T Pressure Reducing Valve WARNING INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

SSR. Smart Valve Positioner.

Simple Set. Pressure Independent Control Valves 2 Way 1/2-2

MP15 Jockey Pump Controller

Automatic Valve Proving Control

Controlling the prefeeder

Richards Industries Basic Siemens PS2 Positioner Functions

WATER CONTROL SYSTEM QUICK START

User Manual for the Mars Calibration Bench

Design DSA Steam-Atomized Desuperheater

Section 4: Sequence valve adjustments

TANK MANAGER FOR TWO TANKS OPERATING MANUAL. 10/31/11 C-More T6C L color touch panel

OPERATING INSTRUCTIONS Pressure Control System PCS-20 through PCS-100

700 SERIES BMS II BUBBLER MONITORING SYSTEM

Burner Management System DEMO Operating instructions

EL-O-Matic E and P Series Pneumatic Actuator SIL Safety Manual

IMVS2000v2 INSTALLATION OPERATING MANUAL MAN720. Integrated Monitoring Valve System. Copyright by BIFFI ITALIA. All rights reserved.

LENNOX SLP98UHV DIAGNOSTIC CODES

Smart performance with innovative and ever-strong coil drive even under harsh working environments

VR46.5V(A)/VR86.5V(A) SERIES

INSTALLATION & MAINTENANCE INSTRUCTIONS DESCRIPTION SPECIFICATIONS. CE (EMC) Compliant

QBS Electronic Pressure Regulator

Beyond Switches for Pump Monitoring:

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY

ISQB1 INTRINSICALLY SAFE ELECTRO-PNEUMATIC CONTROL VALVE INSTALLATION & MAINTENANCE INSTRUCTIONS HAZARDOUS AREA CLASSIFICATION

TECHNICAL DATA. System water supply pressure enters the priming chamber of the deluge valve (A.1) through the 1/4 (8 mm) priming line, which

Connect with Confidence NO POWER NO PROBLEM

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q= Cv S

A4 Operation Manual. Fig.1-1 Controller Socket Diagram

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13

Electropneumatic Transducer (I/P) Installation, Operation and

CHEMICAL ENGINEERING LABORATORY CHEG 239W. Control of a Steam-Heated Mixing Tank with a Pneumatic Process Controller

MODEL RCW NON-INTERLOCK PREACTION SYSTEM

Universal Valve Company Inc

WATCH COLLECTION NG701 SERIES INSTRUCTION MANUAL

Model: 720-UL INSTALLATION OPERATION MAINTENANCE. Bermad Pressure Reducing Valve IOM. Model: FP -720-UL Sizes: 2"-12" BERMAD. Application Engineering

Bermad Pressure Reducing. Model: 42T

Standard Chiller 1/4 compressors Manual version: /10/96

SINGLE VALVE WITH LOW-FLOW BYPASS

Control Valve Training Course Program

Exercise 5-2. Bubblers EXERCISE OBJECTIVE DISCUSSION OUTLINE. Bubblers DISCUSSION. Learn to measure the level in a vessel using a bubbler.

Specifications and information are subject to change without notice. Up-to-date address information is available on our website.

CP3R Quick Start Manual

OXY Integral. INTERCON ENTERPRISES INC Tel: Fax: Internet:

CONTROL VALVE TESTING

Using Modbus Protocol with the ALTUS Net Oil Computer. Instruction Manual

Transcription:

Axiom Detect automated valve problems... before they shut down your process

Reasons for Automated On/Off Valve Failures Monitor Fail Solenoid Fail Actuator Fail Coupling Break Too Slow Leaking Sticking 0% 10% 20% 30% 40% 50% 2

Diagnostics promise to improve uptime and reduce maintenance cost Anticipate valve/actuator failure preventing potential process shut down Develop optimal maintenance scheduling Determine problem cause faster reducing maintenance time Access key information from control room to determine operating health Perform remote settings and calibration 3

Key Benefits of Axiom Diagnostic Models 1. Remotely calibrate and monitor multiple automated valve conditions. 2. Identify root causes for failures quickly. 3. Detect automated valve problems before they shut down the process! 4

HART Diagnostics (AMI71) 1. Remote calibration and monitoring Open and closed switch settings Identification winking Pneumatic pressure low and high alarm settings Monitor exact position, pressure and electronics temperature 2. Identify root causes quickly Low and high pressure alarms Malfunctioning solenoid Stuck pneumatic spool or pilot valve Stuck process valve/actuator 5 3. Predictive Diagnostics Pneumatic pressure alarms Open and closed pressure thresholds Critical parameter trending and baseline comparison Historical trending of key parameters

HART Diagnostics (AMI71) 1. Remote calibration and monitoring Open and closed switch settings Identification winking Pneumatic pressure low and high alarm settings Monitor exact position, pressure and electronics temperature 2. Identify root causes quickly Low and high pressure alarms Malfunctioning solenoid Stuck pneumatic spool or pilot valve Stuck process valve/actuator 6 3. Predictive Diagnostics Pneumatic pressure alarms Open and closed pressure thresholds Critical parameter trending and baseline comparison Historical trending of key parameters

HART Diagnostics (AMI71) 1. Remote calibration and monitoring Open and closed switch settings Identification winking Pneumatic pressure low and high alarm settings Monitor exact position, pressure and electronics temperature 2. Identify root causes quickly Low and high pressure alarms Malfunctioning solenoid Stuck pneumatic spool or pilot valve Stuck process valve/actuator 7 3. Predictive Diagnostics Pneumatic pressure alarms Open and closed pressure thresholds Critical parameter trending and baseline comparison Historical trending of key parameters

HART Diagnostics (AMI71) 1. Remote calibration and monitoring Open and closed switch settings Identification winking Pneumatic pressure low and high alarm settings Monitor exact position, pressure and electronics temperature 2. Identify root causes quickly Low and high pressure alarms Malfunctioning solenoid Stuck pneumatic spool or pilot valve Stuck process valve/actuator 8 3. Predictive Diagnostics Pneumatic pressure alarms Open and closed pressure thresholds Critical parameter trending and baseline comparison Historical trending of key parameters

AMI71 Online DTM 9

AMI71 Device Calibration Calibrate Valve Pressure Unit: Enables you to toggle pressure units between PSI and BAR. Important Note: Pressing this will also clear the cycle count and clear all historical and baseline data. Low Alarm Pressure: Enter the desired low pressure alarm threshold (40 to 95 psi). When pressure applied falls below this level, the Bad Supply Pressure LED on the Axiom unit will flash red and the HART Low Supply Pressure alert will be activated. High Alarm Pressure: Enter the desired high pressure alarm threshold (100 to 120 psi). When pressure applied rises above this level, the Bad Supply Pressure LED on the Axiom unit will flash red and the HART High Supply Pressure alert will be activated. 10

AMI71 Device Calibration Calibrate Valve Stroke Time: Enter the desired stroke time alarm threshold (2 to 650 seconds). This determines the normal maximum stroke time for the valve/actuator. When stroke time exceeds this value the Stuck Process Valve /Actuator LED will flash red and the HART diagnostic Stuck Valve / Actuator alert will be activated. Set Open Switch: Remotely set the open switch limit point (Sets current to 20ma). Determination of Fail Open, Fail Close, Clockwise or Counter-Clockwise operation is made automatically during set up. Set Closed Switch: Remotely set the closed switch limit point (Sets current to 4ma). 11

AMI71 Device Calibration Configure diagnostics: Clear Cycle Count: Clear the cycle count and all historical and baseline data. Set Baseline: Set the last cycle as baseline. Otherwise the 50th cycle will be chosen. Set to Defaults: Return pressure alarms, pressure unit, and stroke time to factory defaults. Loop Current Calibration D/A trim: This method allows the user to trim the loop current to zero and span to match the input device or current meter. The procedure first trims the 4mA output to match his local meter and then the 20mA output again to match the local meter. Loop Current: This method allows the user to set the loop current to a fixed value. This allows the user to check out other devices in series with the loop such as current monitors, etc. The method provides fixed choices of 4, 12 and 20mA as well as allowing the user to input a value between 4 and 20mA of his choosing. 12

AMI71 Diagnostics / Status Device Status has status/warning flags for HART related communications. Operation Warning will give warning indications about the function of the device. A green indication is a good condition while a red indicates a problem or in the case of Baseline Not Set, signifies that that the baseline has not yet been set. The baseline will be set on the 50th cycle or when set baseline is pressed. 13

AMI71 Observe / Live Device Variables Valve position (degrees): Current valve position in degrees Air pressure (PSI/BAR): Current Inlet air pressure (PSI or BAR) Temperature (C): Current Temperature of the electronics module (degrees C) Solenoid Power (Indicator light): Indicates state of solenoid output (On/Off) Valve position indication: Open or Closed Loop Current: Current flow in 4-20mA signal wires Valve % open: Indicates how far, in degrees, the valve is open. Cycle count: Number of closed open-closed cycles since last reset 14

AMI 71 Historical Data (Trends) Historical Data: These graphs shows the last 16 cycles with the latest cycle on the left. As you accumulate more cycles, the older data is averaged and stored. The red line is the baseline value for this parameter. 15

Historical Data (Open Dead time) Open Dead time is defined as the time delay from toggling the solenoid until the valve begins to open. What does this tell me: This value provides a historical look at the time it takes from energizing the coil until the valve starts to move. What could cause it to change: If the open dead time is increasing, that could be caused by partially clogged air lines or by sluggish but functional solenoid coil or spool valve. What can I do to address this: Inspect the air lines for blockages or debris. Inspect / rebuild the spool valve. Inspect the Pilot valve screens for debris. 16

Historical Data (Close Dead time) Close Dead time is defined as the time delay from toggling the solenoid until the valve begins to close. What does this tell me: This value provides a historical look at the time it takes from deenergizing the coil until the valve starts to move. What could cause it to change: If the close dead time is rising, that could be caused by partially clogged air lines or by sluggish but functional solenoid coil or spool valve. What can I do to address this: Inspect the air lines for blockages or debris. Inspect / rebuild the spool valve. Inspect the Pilot valve screens for debris. 17

Historical Data (Open Breakaway pressure) Open Breakaway Pressure is defined as the pressure differential across the piston at the point where the actuator starts to open the valve. This closely follows breakaway torque and can be used to diagnose problems like sticking valves. What does this tell me: This value provides a historical look at how much pressure differential across the piston is required to begin movement of the actuator/valve from the fully closed position. What could cause it to change: If the Open Breakaway Pressure is rising, breakaway torque is also increasing. This could indicate that a valve is sticking to the seat. What can I do to address this: Valve service may be needed. 18

Historical Data (Close Breakaway pressure) Close Breakaway Pressure is defined as the pressure differential across the piston at the point where the actuator starts to close the valve. This closely follows breakaway torque and can be used to diagnose problems like sticking valves. What does this tell me: This value provides a historical look at how much pressure differential across the piston is required to begin movement of the actuator/valve from the fully open position. What could cause it to change: If the Close Breakaway Pressure is rising, breakaway torque is also increasing. This could indicate that a valve is sticking to the seat. What can I do to address this: Valve service may be needed. 19

Historical Data (Open time) Open Time is defined as the time it takes for the valve to open. What does this tell me: This value provides a historical look at how long it takes the valve to open. What could cause it to change: If the Open Time is rising, it is simply taking longer for the valve to open. This could indicate that the valve is sticking, or air leakage through the fittings. It could also indicate a sluggish spool valve or pilot valve. What can I do to address this: Valve or actuator service may be needed. Spool valve service may be needed. 20

Historical Data (Close time) Close Time is defined as the time it takes for the valve to close. What does this tell me: This value provides a historical look at how long it takes the valve to close. What could cause it to change: If the Close Time is rising, it is simply taking longer for the valve to close. This could indicate that the valve is sticking, or air leakage through the fittings. It could also indicate a sluggish spool valve or pilot valve. What can I do to address this: Valve or actuator service may be needed. Spool valve service may be needed. 21

Historical Data (Open Temperature) Open Temperature is defined as the temperature reading from the temperature transducer inside the electronics module measured when the valve reaches open. What does this tell me: This value provides a historical look at the temperature seen by the Axiom's C-module (Electronics module) during the open cycle. What could cause it to change: Ambient temperature fluctuations or internal heat rise. What can I do to address this: If the temperatures exceed the temperature rating of the device, life of the device could be reduced. Consider heaters / coolers or insulating the surrounding pipes/tanks to protect electronics from exposure to temperatures they are not designed to handle. 22

Historical Data (Close Temperature) Close Temperature is defined as the temperature reading from the temperature transducer inside the electronics module measured when the valve reaches closed. What does this tell me: This value provides a historical look at the temperature seen by the Axiom's C-module (Electronics module) during the closed cycle. What could cause it to change: Ambient temperature fluctuations or internal heat rise. What can I do to address this: If the temperatures exceed the temperature rating of the device, life of the device could be reduced. Consider heaters/coolers or insulating the surrounding pipes/tanks to protect electronics from exposure to temperatures they are not designed to handle. 23

Historical Data (Close Setpoint Change) Close Setpoint Change is defined as the amount the closed setpoint has changed. This parameter can indicate problems such as valve seat wear or buildup. What does this tell me: This value provides a historical look at the amount the closed position setpoint has been changed. The setpoint is set by the user. This shows how much it has changed over time. What could cause it to change: Only users can change this, either with the onboard push buttons or in the configuration screen. If the users are changing the setpoint they could be doing so because they are no longer reaching the desired setpoint. (overtravel or undertravel) If the setpoint is not being reached, this could indicate that the actual valve travel has changed. What can I do to address this: This could be caused by worn seats or buildup in the valve. Valve service may be needed. 24

AMI 71 Installation 25

AMI 71 Installation 26

Asset Management Systems Using systems that accept EDDL (Electronic Device Description Language) - Download EDD from www.stonel.com - Typical EDDL compatible asset management systems include: Emerson AMS Siemens PDM Honeywell FDM Using systems that run FDT (Field Device Tool) - Download DTM (Device Type Manager) from www.stonel.com - DTM is loaded into FDT frame program which is part of DCS or a separate PC - Typical FDT compatible systems include Honeywell FDM FieldCare Yokogawa PRM ABB AVM 27

Axiom Detect automated valve problems... before they shut down your process